w Babcock &Wilcox eo e,cenerationoroup P.O. Box 1260. Lynchburg, Va. 24505 Telephone: (804) 384 5111 October 12, 1977 DOCKET STN 50-561 Office of Nuclear Reactor Regulation ATTN:

Mr. Roger S. Boyd, Director Division of Project Management U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Subject:

B-SAR-205 Transmittal of Amendment 19

References:

1)

Report to the Advisory Committee on Reactor Safeguards by the Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission, in the matter of Babcock 5 Wilcox Company Reference Safety Analysis Report, B - SAR-2 0 5,

Docket No. STN 50-561, July 9, 1977 2)

James H. Taylor to S. A. Varga, September 30, 1977, with attachment

Dear Mr. Boyd:

The Babcock 4 Wilcox Company herewith submits sixty copies of B-SAR-205 Amendment 19 for review.

The amendment contains the fo lowing specific items:

1)

Figure 212.239-1 has been revised in accordance with telephone conversations held with the Staff on October 3, 1977.

2)

Figure 8.3-1 has been clari fied to show the power supply to decay heat suction isolation valves DH-VilA and f

DH-V11B.

3)

Figure 9.3-5 has been revised to show the addition of manual isolation valves MV 36A and B.

These valves will allow isolation of decay heat train equipment for maintenance during shutdown when all decay heat suction isolation valves must be kept open to provide overpressure protection.

8201110799 810403 l

PDR FOIA MADDEN 80-515 PDR The Babcock & witecx company / Estabhshed 1867

' Babcock &Wilcox Mr. Roger S. Boyd Page 2 October 12, 1977 4)

Section 3.11.6 concerning environmental temperature qualification levels has been clarified in keeping with telephone agreements with the Staff.

5)

Section 10.5.15 concerning secondary system interfaces has been amended to assure that the design will be consistent with SLB accident analysis assumptions.

6)

Sections 6A.S.3 and 6A.5.4 have been revised in accordance with telephone discussions with the Staff.

7)

The time period shown for " minimum time to criticality" in Table 15.1.4-2 for the startup mode has been corrected as agreed to by the Staff during a telephone discussion with the Staff on October 4, 1977.

8)

The required CRA trip insertion time to 2/3 insertion shown in Table 15.1.2-1 has been corrected to 1.7 seconds.

9)

A number of typographical and format errors have also been corrected in this amendment.

With regard to outstanding issue number 9 in Table 1.6 of Reference 1, please be advised that the results of the large break spectrum for the B6W 205 FA standard NSS has been submitted to the Staff separately as an attachment to Reference 2.

truly yours,

/

/

James H. Taylor Manager, Licensing JHT:dsf Attachments I

f l

l l

\\

i

l 1

J J&six:ockkMnkox f

Mr. Roger S. Boyd Page 3 October 12, 1977 cc:

R. B. Borsum (B4W)(2)

U. S. Nuclear Regulatory Commission (1)

Office of Inspection and Enforcement - Region IV 611 Ryan Plaza Drive - Suite 1000 Arlington, Texas 76012 Mr. Neil Thomasson (3)

Attn:

Loretta Long Office of Radiation Programs Environmental Protection Agency Room 647A East Tower Waterside Mall 401 M Street, S.W.

Washington, D.C.

20460 Mr. A. J. Oswald (1)

EGGG Idaho, Inc.

P. O.

Box 1625 Idaho Falls, Idaho 83401 1

i

.s

/

'3abcock&Wilcox STATE OF VIRGINIA)

)

SS. Lynchburg CITY OF LYNCHBURG)

James H. Taylor, being first duly sworn, deposes, and says:

That he is the Manager of the Licensing Section of the Nuclear Power Generation Division, THE BABCOCK 4 WILCOX COMPANY, the applicant herein; that he is authorized to submit the foregoing on behalf of said applicant; that he has read the foregoing and knows the contents hereof; and believes the same to be true to the best of his knowledge.

Dated:

j t // /8M f///"

/k A-

[ James H. TayIor Subscribqd and sworn to before me, this /4" day of October, 1977.

&W Ad NotIry Public in and for the State of Virginia, City of Lynchburg

/4,//c,/p/

My Commission expires l

e snu 195 u.s.NuCLsAn occut ATo::V CoMMisSti N

QQCKET NUMBE R So - Sfo I

\\

NRC DISTRIBUTION Pon PART 50 DCCKET MATERIAL jpS{AMDTDIST.

pg

  • TO.

FROM:

QATE CP CCCUMENT S Boyd Babcock & Wilcox 10-12-77 I

Lynchburg, Va o,7,,,eggy g o l

J H Taylor 10-13-77 j Zi.1TTER YNOTORIZE D PRCP INPUT PCMM NUMSEM QP COPf E3 REC 11VED j

GCMiGIN AL.

MNCLASStPIE D CCcPv 3 S F/utdO ENC:.OsU RE

Ot5CMIPTlCN i notarized 10-12-77.....trans the following

Amde #19 to B-SAR-205: Consisting of revised &

addl pgs, tables, figs & info to the'SAR........

1 3p 1/4 inch

]

4 i

PLANT NAME:

B-SAR-205 10-14-77 ehf 60 guC(.,

i FOR ACTION /INFORMATION IGNED AD:

(LTR) i

//e4,.5'AN / O i

NCH CHIEF:

I I erf0 JECT MANAGER:

if CogN I LICENSI'M ASST (LTR)f

-fra_u/ decor t i l

i i i i

i INTERNAL DISTRIBUTICN I REG ETLE i LAINAS 4 i l l j

l NRC PDR l IPPOLITO I I i I

' ICE (O I F. ROSA l

l i

I I rwtD ( LTR')

i GA.'0!ILL (2) i l

P. COLLINS l VOLLMER (LTR) l l l

I HOUSTON I i BUNCH I

I i i HELTEMES I

J. COLLINS I

l i l CASE (LTR)

KREGER i

l }

l l MIPC (LTR) i I

i l i

i I iCIIGHT (LTR) l l

I i

l ! BOSNAK i i i

I l SIHWEIL i

i 1

I PANLICKI l l 6

t i ROSS (LTR)

{ l i

i NOVAK i I l

4 POSZTOC Y l

I i i l i i CHECK l l 1

1 I I

t i IEDESCO tLTR) j i e

i l i

i,

'ENAE0YA I I i

l 1 l

6 EXTERNAL DISTRIBUTICN CONTROL NUMSER I

I

_.,mem=-

I t i I l

i TIC l l t i i i vs C i !

I t

_____.,,1

I ACRS 16 CYS SENT CATEGQRY 9 l l I

i i

> a e

! i