UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE ATOMIC SAFETY AND LICENSING BOARD

)

Ir. the Matter of

)

)

METROPOLITAN EDISON COMPANY, et al.,

)

Docket No. 50-289

)

Restart (Three Mile Island Nuclear Station,

)

Unit No. 1)

)

)

Q b.

9 UNION OF CONCERNED SCIENTISTS p@st PROPOSED FINDINGS OF FACT AND

,g CONCLUSIONS OF LAW ON UCS 6 gg$\\ P 3g% 1

[7 CONTENTIONS NOS. 13 and 14 AND BOARD QUESTIONS 2 AND 6 SP

' pb

/

q[h n>

</

4 Ellyn R. Weiss RARMON & WEISS 1725 I Street, N.W.

Suite 506 l

"""s!"!!2606 DATED:

June 12, 1981

!8.10 619 0 l'bi s 1

Table of Contents UCS Contention No. 13 page 129 Board Question No. 6 page 166 UCS Contention No. 14 page 195 Board Question No. 2 page 229 g g pg 9

$N g.,

a O

Ng d q.

+

'to W

\\

e 9

g

.s

-129-o UCS Contention No. 13 was accepted for litigation by this Board as follows:

"The design of TMI does not provide protection against so-called ' Class 9' accidents.

There is no basis for concluding that such addicents are not credible.

Indeed, the staff has conceded that the accident at Unit 2 falls within that classification.

Of the realm of possible accidents, the staff's method of determining which fall within the design basis accidents and those for whi,ch no protection is required is faulty in that the design basis accidents for TMI do not bound the credible accidents which can occur.

Therefore, there is not reasonable assurance that TMI-l can be operated without endan-gering the health and safety of the public and resumption of operation should not be permitted."

l 314.

UCs made it clear that the essence of its contention is that the staff has no technically supportable method I

i

'or classifying particular accident sequences as either I

credible or not credible.

(Union of Concerned Scientists and i

-Steven C. Sholly Joint Proposed Reply Procedural Findings, t

5/18/81, at 14-15).

?

~

-130-315.

The term "Clas's 9" accidents is derived from a' proposed' rule published by the Atomic Energy Commission in 1971.

The proposed rule, which has now been withdrawn by the Nuclear Regulatory Commission, set forth a system of classification of potential accidents for use in NRC Staff assessments performed pursuant to the National Environmental Policy Act of 1969.

The proposed rule 1

set forth-a spectrum of accidents divided into nine classes ranging from trivial in nature to the most severe for the purposes of evaluating environmental risk.

- 316. -Class 9 accidents were characterized in the proposed

,o rule as'"involv(ing) sequences of postulated successive failures more severe than those postulated for the design basis for protective systems and engineered safety features."

These events, characterized as beyond the design basis, l

were not explicitly assessed in determining the adequacy of~the facility design.

For the purposes of analysis pursuant 4

to.10 CFR Part 100, Class 9 accidents were considered as "not cred'ble".

(Rosenthal and' Check, ff. Tr. 11,158, at 6-7) i t

i 8

e 4

+3

-1 1=

c-3

+

-131-317.

The design basis is the set of prescribed anticipated operational occurrences and accidents used to essess the way specific systems respond to upset conditions.

Design-basis events (DBE's) are events or sequences of events which fall within the design basis.

DBE's provide a set of analytic tests of the plant design, consisting of sample challenges to the plant safety systems.

These tests are used by the Staff to determine if installed or proposed safety features can cope adequately with the DBE's (Rosenthal and Check, ff. Tr. 11,158, at 4).

O 318.

An explicit list of DBE's is not provided in the Commission's regulations, but must be found on a system-by-system basis for each plant in the Final Safety Analysis Report (FSAR), the Technical Specifications, applicable reference or topical reports, and related design documents (Rosenthal and Check, ff. Tr. 11,158, at 3).

The set of DBE's now used by the Staff to test the overall adequacy of I

the plant design was not developed until the mid-1970's I

(Rosenthal and Check, ff. Tr. 11,158, at 17-18).

A listing I

of events to be considered is included in Regulatory Guide x

1.70, Standard Format and Content of Safety Analysis Reports for Nuclear Power Plants (Revision 2), issued in 1975 (Levy, 1

~

.m n.

e 1

-132-

=

ff. Tr. 11,049, at 2).

The Board notes in this context that TMI-l received its operating license in April 1974.

319.

The response of each plant to the DBE's is assessed using the requirements stated in the General Design Criteria (10 CFR Part 50, Appendix A) and other standards forth in the Standard Review Plan and Regulatory Guides.

set The consequences of DBE's are assessed against the requirements of 10 CFR Part 100; for the purposes of this analysis, DBE's are considered to be " credible" events (Rosenthal and Check, ff. Tr. 11,158, at 5).

Since the withdrawal of the AEC's proposed rule 320.

by the Commission, the term " Class 9" accident has no formal meaning, but it is in common usage.

The Staff uses the phrase

" events beyond the design basis" as equivalent to the term

" Class 9" (Tr. 11,245-46, Rosenthal).

The Staff's use of the design-basis event l

321.

concept and the manner in which this concept is applied in the licensing and safety review process is quite clear to

'his Board and would be' acceptable if the Staff had a scrutable,. i

~

~

Snically jusYifiable metWod~of ddterniining which events ara te (i.e., within the design basis) and which are credi, e not cret ble (i.e., beyond the design basis).

It is fundamental that in order to make a reasonable assessment of the safety of nuclear plants one must have knowledge of the likelihood of a particular event or sequence of events.

l Once one understands the likelihood of an event or sequence, e

O h

p the consequences of the event or sequence must be understood.

i Understanding the' likelihood and consequences of an event or sequence, one is then in a position to determine, based on appropriate criteria, whether the event or sequence needs to be protected against (and hence should be included within the design basis), or whether no such protection is required (and hence should be excluded from the design basis).

The evidence and testimony presented to this Board demonstrates quite clearly that the Staff has no scrutable method for making the determination of credible or not credible.

The most widely recognized study which produced 322.

probability estimates on various events and sequences of events was WASH-1400, the so-called Rasmussen Report (Reactor Safety Study, October 1975).

The NRC, in response to criticisms of e

WASH-1400, formed a panel to review 9 ASH-1400 (the panel has become known as the Lewis Committee, after its Chairman, Harold Lewis, now a member of the Commission's Advisory Committee on Reactor Safeguards).

In " Report of the Risk Assessment Review Group to the U.S. Nuclear Regulatory Commission" (NUREG/CR-0400, September 1978), the Lewis Committee questioned the i

absolute probability numbers used in WASH-1400, stating:

i "We are unable to determine whether the absolute probability of accident sequences in WASH 1400 are high or low, but we believe that the error bounds on these estimates.are, in general, greatly-l underestimated.

This is true in part because there is in many cases an inadequate data base, in part because of an inability to quantify I

common cause failures, and in part because of some questionable methodological and statistical I-procedures." (Rosenthal and Check, ff. Tr.

~

11,158, at 24).

  • e

-134-

^ -

4

~ 323.

~In a January 19, 19,79 Policy-Statement, the Com-mission withdrew any endorsement of the Executive Summary of WASH-1400 and noted-that. the Commission "does not regard as

~

~

reliable the Reactor Safety Study's numerical estimates of the overall risk of reactor accident."

Licensing Boards were cautioned not to rely-on the probability estimates in WASH-1400 as a basis for'their. decisions.

It became clear in the litigation of UCS Contention 324.

No.-13 that the Staff has no numerical estimates of overall plant f

reliability for TMI-1.

The Staff estimated that a year would be i

required to generate such numbers (Tr. 11,242, Tourtellotte; Tr. 11,242-43, Check).

The Staff has no probability numbers, is not attempting to generate such numbers, and therefore does not rely on probability numbers (Tr. 11,165-67, Tourte11otte).

The l

Staff has not. evaluated and does not know the probability that an I

accident beyond the design basis of TMI-l will cccur (NRC Staff Response to Union of Concerned Scientists First Set of Interrogatories, March 7, 1980, answer to Interrogatories 134 and 135, as cited in

-Union of Concerned Scientists Motion for Summary Disposition of f

UCS Contention No.13, which went unchallenged by the NRC Staff).

The. Staff.has no prevent means to reliably estimate the probability that accidents which it deems or deemed incredible will in ' fact f,

- occur, and does not know how many other accidents previously deemed " incredible" are, in fact, credible (Union of Concerned

- Scientists Motion for Summary Disposition of UCS Contention No. 13, i

at 3-4).

325.-

-In. fact, the Staff acknowledged that prior to responding to this contention, the Staff had not " set down in

Aaa-r aufficient' clarify for all to follow" the Staff's method of analyzing and classifying accidents, and that "this was a very appropriate time to' reflect and try to set down clearly, if we could, what it is we do and how we do it.."

(Tr. 11,192, Check).

The Staff's testimony makes it clear that the Staff never, prior to this proceeding, had a clearly defined method for classifying accidents as credible or not credible, and that the Staff's testimony represents a post hoc effort at rationalizing, for the purposes of this particular litigation, both the lack of a clearly stated methodology and the actual lack of a technically scrutable method for classifying accidents.

There is an inherent evidentiary weakness in such testimony.

The Board notes that there were numerous recommendations 326.

made by the Lessons Learned Task Force which relate to this very problem, that of classifying accidents. -Although the examples which tise Board will cite are long-term items, the Staff has clearly turned a blind eye toward them in responding to this contention,.

and has gone about responding to the contention in a " business-as-usual" framework.

Among the recommendations of the Lessons Learned Task Force are the following:

That.the Staff perform a systematic assessment a.

of the reliability of safety systems in operating plants (NUREG-0585, at A-14).

b.

That the number of failures in non-safety equip-ment that are considered in accident analyses should reflect the expected number of non-safety systems simultaneously exposed during the event under study to conditions for which they were not designed or qualified (NUREG-0585, at A-14).

c.

That the use of probabilistic analysis to supple-ment the " deterministic" analysis normally done in the past be implemented.

The Task Force noted, "There remains, however,.the possibility that significant event sequences have been overlooked and'not included within the current design basis

- - h e=beegewsee,

-e e.

. ts u :

events,_or that the deterministic design requirements-are incomplete or. inadequate for some events and systems." (NUREG-0585, at 3-1 te 3-2).

d.

Th'at the general' safety criteria should be revit e d, including.the issue of whether to modify or extend the current design basis (NUREG-0578, at 16-17).

According to Staff witnesses, the " method used by 327.

the Staff to characterize events or sequences of events as " credible" or "not credible" is " engineering judgment informed by engineering assessment of the performance characteristics of the various systems and components in a nuclear power reactor, and of the kinds of system or component failures that may occur" (Rosenthal and check, ff. Tr. 11,158, ar 16-17).

328.

From the Board's perspective, this only states l

the obvious.

Any method of determining.which accidents are c'redible and which are not_ credible, regardless df whether that -method involves probabilistic risk assessment, fault-tree analysis, event-tree analysis, or some combination of these or other methods, ultimately rests on engineering judgment.

In the Board's view, it is how that engineering judgment is applied that is the key--how one reaches the determination of what is credible and what is not credible is at the very heart of this issue.

The 1

. bottom line is that the Staff has no method of making such a-t-

1 determination.

It is unusual in writing a decision that a Board I

relies on exact quotes from the record, but'in this instance the Staff's own words speak quite clearly to the problem.

L e

w M..-,.-.--

)*O" w4 ~~ A--

m'M

As,-

fl, F

O 329.

The' Commonwealth of Pennsylvania's nuclear engineer, Mr. Dornsife, requested the Staff, in cross-examination to describe whether:there are any strict criteria or" guidance used by the Staff to determine what is or is not a credible event or sequence of' events.

The responses of the two Staff witnesses were astonishing:

"There.is no numerical safety goal.

There is no numerical cutoff between credible and not credible in terms'of probabilistic numbers or numbers of failures that would have to L

occur.

There is no definitive test."

(Tr.

(

11,203, Rosenthal).

"And a specific answer to your question is no, there is no guidance given to the Staff which enables it to declare an event or sequence of events credible or not credible."

(Tr. 11,203, Check).

.This testimony alone would be su#ficient, or nearly 330.

so, to, sustain UCS's contention that the Staff has no technically justifiable method of classifyin,g accidents as either credible or incredible.

It i d_ stes clearly that there are no criteria

(

used by the Staff 3 armining whether concededly possible

~

accident sequence 6 are,eith'Er not " credible", or should be include i

within the design basis.

It should'be~noted that-the total absene of regulatory criteria raises a ques' ion going beyond the issue of the probability or likelihood of ' par ticular accidents.

Even if all parties agre-d that the probability of accident "X" were 10 or any other number, the question-would still remain:

~

should that accident be within or outside the design basis?

l

?

As to this question -- the definition of " credible" 'for the l

purposes of design -- neither the Staff nor the Licensee has presented any evidence.

3 i

m

-~--w-.

n

. -ww w...

138-4 331.

-Mr.

Dornsife then asked the Staff witnesses if there were any qualitative goals 1or qualitative criteria which the Staff used in making a determination of whether an event or sequence of events is credible ornot credible.

The only example which the Staff witnesses could point to was the single-failure criterion.

(Tr. - 11,2 04, Check)

The Board will return to the s' ingle-fai.ure criterion below.

J i

Y E

I

+

in 3

.1 g

b e

em J

e 4

-n---

7

' -139-Y d-332.

An even more_ telling piece of testimony was given by Staff witness check:

"We do not have a process that I could describe.for you easily that-would spit out an answer, credible or incredible, when we embark on a study of events.

We described the deterministic, the engineering judgment, the deterministic approach that (we have). employed for the past several decades, and how we have

.gotten to the point of evaluating certain events and perhaps not others.

Now it is a reasonable inference, I suppose, to say well, the Staff believes, and therefore, this event is credible and this event is not.

I can see now -- how you can make

~'

that judgment, and in fact, I guess that' is implied in what we do.

(Tr.

11,199, Check).

333.

It is quite clear that the Staff has no scrutable method by which it determines whether events or sequences of events are credible or not credible.

Returning now to the issue of the use of the single-failure criterion, it became clear as a result of cross-examination that the single-failure criterion is not without its problems.

The single-failure criterion grew out of work on electrical components in which the reliability of each of the trains was rather high, and, in such a case, the adoption of single level redundancy was appropriate.

However, the Staff adopted the single-failure criterion across the board.

The Staff now concedes that perhaps this was the wrong approach (Tr. 11,204-05, Rosenthal).

O.

WED..

  • 9 e

ep -

a he d

A

r

-140-

~

334.

The Staff testified that the single-failure cri-terion is not appropriate for use in connection with requirements for diesel generators (Tr. 11,205, Rosenthal).

335.

As the Board discussed in Finding No.

8, suora.,

-it is fundamental that in order to make a reasonable assessment of the safety of nuclear plants one must have knowledge of the likeli-hood (i.e., probability) of a particular event or sequence of events The Staff, both technical members and legal counsel, repeatedly told this Board that the Staff does not rely on probability numbers or estimates.

Yet, it is quite clear that the Staff implicitly re-lies on-probability, even though actual probability numbers are not generated by means of a calculation or assessment process.

The Staf:

relies on its " sense of more or less what is probable, what is highl3 improbable in an engineer's mind" (Tr. 11,200-01, Check).

Thus, whether by engineering judgment, formal. risk. assessment, or. some com-bination of the two, any attempt to classify accidents as credible or incredible depends fundamentally on the probability of occurrence of the accident in question.

336.

As the Staff candidly testified, "There is the impli-I cation of an understanding of probabilities in this thing we have called a deterministic approach."

(Tr. 11,253, Check).

This is self-evident.

337.

Moreover, the Staff used its implicit understanding of probabilities in the selection of events or event sequences to be analyzed in safety analyses (Rosenthal & Check, ff. Tr. 11,158, at 20).

The Staff testified, however, that it did not use any pro-

-ability numbers from WASH-1400 (Tr. 11,160-61, Rosenthal).

The question to be asked, then, is where did the Staff obtain its

-A*2-

'" implicit" understanding of probabilities? 'The Staff is apparently.

relying on its judcment of probabilities.

to arrive at the The-Staff used its judgment 338.

(Levy, ff. Tr.

of DBE's used1to define the design basis

-set L11,049, at 2; Rosenthal and Check, ff. Tr. 11,158, at 4-5, 17, 20).

\\

The Staff uses its judgment in the same manner to evaluate operating experience and new failure modes and failure sequences this As t he Board will shortly explain,

'(Tr. 11,248, Check).

set of requirements same process was used in originating the and later in which came,to be embodied in the TMI Action Plan, t

rests on Ne shall now consider whether this judgment NU REG-0 7 37.

sound ground.

events or 339 Tne Staff, in its analysis of what credible, relies' on sequences of events are credible or not its engineering judgement as supplemented by the Staff's ics engineering assessment of the performance characterist of.the raactor systems and components and, more importantly the staff's engineering judgment of in the Board's view, failures that may occur.

"the kinds of system or component ff. Tr. 11,158, at 16-17).

The Staff (Rosenthal and Check, failures; failures limits itself to consideration of single i

of accident mitigating systems are considered on the bas s ff. Tr. 11,158, (Rosenthal and Check, i

of single failures compounding of causally unrelated failures is something at 20);

and does not consider the Staf f considers to be highly improbable, i

'I

,~

at all.

(Tr. 11,201, Check)

The single-failure criterion i

regulatory is embodied in the Commission's regulations, (See, 10 CFR Part 50, l

and the Standard Review Plan

guides, Appendix A, Introduction, GDC 17, GDC 21, GDC 24, GDC 34, y

9 y

'GDC 35, GDC 38, GDC 41,.and GDC 44).

In spite of a recommendation by. the President's Commission on the Accident at Three Mile Island that there be increasec attention to the possibility of

. multiple failures, Staff witness Wermeil could not point to any new requirements.that multiple failures be considered in evaluating the emergency feedwater system, for example (Tr. 16,75T 57, Wermeil).

The witness was aware of a general pursuit of this particular recommendation in other areas, but provided no examples (Tr. 16,757, Wermeil).

The Staff has totally eliminated any consideration of the occurrence of two or more random equipment failures as initiating events by, on the i

basis of Staff judgment, precluding such failures from the design basis (Rosenthal & Check, ff. Tr. 11,158, at 20).

In fact, the only criterion which the Staff could name which is used in determinations of whether eients or event sequences L

are credible or not credible is the single-failure criterion i

r j,

(Tr. 11,203, Check).

l l

340.

The Staff's use of the single-failure criterion is typically limited by the General Design Criteria of.10 CFR l

Part 50, Appendix A, to evaluations of safety-grade systems.

i I

However, if the Staff's evaluation of the B&W report in the Integrated Control System Reliability Analysis ( B AW-15 6 4-) is i

p any indication, the Staff is extending this principle to h

even non-safety-grade systems such as the ICS (Tr. 7005, Joyner; Licensee Ex. 18, at 4-1, 4-2: Tr. 6964, Joyner; Tr. 7240, Thatcher).

t

[

~

-143-341.

This over-riding reliance on single failures is not warranter As Oak Ridge National Laboratory observed, "The serious safety problem.

experienced in operating reactors have, in general, involved multiple failures, or sometimes a single failure compounded by operator error."

(Sholly Ex.

2, it 10)

The TMI-2 accident, which according to the Staff was a Class 9 accident (i.e.,

an accident beyond the design basis)

(Rosenthal and Check, ff. Tr. 11,158, at 8), was caused by a common mode failure of redundant trains of high-pressure injecticn (HPI) resulting primarily from operator error.

(Tr. 11,238, Rosenthal; Use of the single failure criterion results in the classification of the TMI-2 accident as incredible.

342.

Multiple failures were postulated in the Staff's " Class 9" accident sequence study (NRC Staff'Ex.

3, at 7-11).

Fopr of the seven postulated loss of main feedwater sequences led to a loss-of-coolant-accident (LOCA), namely sequences designated as TQ, TP TL, 2,

and TLP (NRC Staf f Ex.

3, at 13).

Of the ceven sequences beginning 2

i with a LOCA, five of these sequences lead to core melt, namely'se-quences designated as BH, BP, BRH, BRP, and BD. (NRC Staff Ex.

3, at 14).

Some of the core melt sequences lead to containment failure, namely sequences designated.as".BPP (NRC7 Staff _Ex.

3 7. at.16) ; and any loss-of-feedwater sequences which end with the BP LOCA sequence, namely sequences designated as. T Sf (ibid., at: 21), T 'S '

(ibid.,

7 33 at 26), T6 id.,

at 3D, and T (ibid., at 36).

In all such~

53 63 cases, containment fai' lure is caused by failure of post-accident hea t removal (PAHR).

l 343.

The Staff explicitly precludes any consideration of i

6 i

q

-144-

~

score melt and/or containment failure accidents (including the 1TMI-2' acciden t - sequence)' within the design _ basis because such

~

events. and event -sequences involved multiple f ailures ~(Tr.

m 11,246 Rosenthal).

The Staff'goes even further, however, and concludes that:on the basis of the implementation of tha measures specified in'the Staff's " Class 9" accident report (NRC Staff Ex. 3), the event sequences with close nexus to the TMI-2 accident' "aren no. longer-dominant ' contributors to. total risk, but rather represent risks consistent with other contributory

!sks of the: facility as a whole.

In this sense, the probability of these event sequences occurring and leading to core melt, with

_ concurrent or. consequential containment failure such.that Part 100 guidelines are exceeded, is sufficiently low that these event

' sequences may be considered not ' credible. ' " (Rosenthal and Check, ff. Tr. 11,158, at 16)

Ho, wever,,since the Staff has not quantified the probability of progressing up or down on the event trees in the Staff's core damage sequence accident report (NRC Staff Ex.

3, at 13-

14) (Tr. 11, 250, Rosent nal), the Staff simply has no basis for',

~

I concluding that this is the case.

~344.

This conclusion appears to be consistent with.

Staff. practice concerning actual operating experience.

As the Staff testified, "As we learn of new potential failure modes and failure sequences we explore them and we evaluate them in the way we had evaluated design basis events.

(Tr. 11,248,

{

Check) Board emphasis.

Apparently, the Staff has examined the TMI-2 accident sequence, concluded that the proximate cause.

was'a common mode failure of redundant HPI trains caused primarily by operator error (Tr. 11,238, Rosenthal), and therefore concluded

.m

that ' sinc 2 the TMI-2 accident involved multiple failurcs it was beyond the design bas.is (Tr. 11,24 6,.

Rosenthal).

Had the TMI-2 accident not actually happenec, out rather had it been predicted on the basis of an analysis, the Staff would have declared this sequence to be beyond the design basis and dismissed it as not credible.

As the Staff testified, either it is a design basis accident, or it is not and, therefore, one need not worry about it (Tr. 11,248-49, Check).

345.

However, since the TMI-2 accident represents actual operating experience, rather than an analytical result, the Staff was forced by circumstances to do more.

Two products of this addi-tional effort are the TMI Action Plan (to which the Board will late:

address itself) and, as a result of considerable prodding by the-Board in this proceeding, the Staff's " Class 9" report, "TMI-1 Po-tential Core Damage Accident Sequences and Preventive apd Mitigative Measures" (June 1980) (NRC Staff Ex. 3).

As discussed above, the Staf f's core damage accident report : revealed that there are several sequences with nexus to the TMI-2 accident which result in core melt, some also involving containment failure (See, Finding No. 26, supra.).

As a result, it was necessary for the Staff to attempt to prove that these sequences were not " credible."

It undertook to do-g so by attempting to demonstrate that post-TMI-2 improvements or modt

?

fications moved these accident secuences from the realm of the cred:

eI ble to the incredible.

The Staff's core damage accident sequences report cites many pager, of recommendations and changes proposed by the Staff, most of which correspond to items in the TMI Action Plan.

Before addressing the specific recommendations in the core damage sequence report, the Board will address the genesis of the TMI Actic Plan.

w

7

-146-4 346.

By the Staff's own testimony, the TMI Action Plan arose from the traditional way in which the Staff has done

business, i.e., "to' consider virtually everything that occurs to us, starting from the reviewer level and having suggestions reviewed internally through several stages of management, having them amplified, having them focused, and then having discussions first with the ACRS and subsequently with the Commission itself, and at each-stage learning from the discussions, incorporating the good that came of those discussions, and in that way developing a sound engineering regulatory approach to the problem." (Tr. 11,180-81, Check).

347.

Staff witnesses Ross and Capra testified before the Board on Board Question No.

2, which was intimately related. '

to the consideration of accidents beycad the design basis.

Board Question No. 2 was stated by this Board as follows:

"(Tr. 2392)

"The Board stated its concern with having an adequate record on the sufficiency of the proposed.short-term and long-term actions to protect the health and safety of the public.

Without further explanation the question may appear to invite conclusionary testimony of the l

ultimate factual isenes to be decided by the Board.

(Commission's August 9, 2979 Order, 10 HRC 141, 148.)

This is not what the Board-has in mind as a resoonse to the cuestion.

Our concerns were express'ed in part in the June 23, 1980 memorandum on the Staff's report on IMI-1 accident sequences.

To explain further:

We assume that the Staff and Licensee may present evidence that each Category A and each Category B recommendation in Table B-1 of NUREG-0578 (Order items ST 8 and LT 3, and that each preventive and mitigative measure identified with respect to a given accident sequence in'the Staff's TMI-l Core Damage Accident Sequence Report will be, at least, sufficient to resolve the related safety problem or accident sequence.

However, nowhere have we seen in the

,e e

f%h

-~

c r

^

-147-l t-

'RestartrReport, SER, the Accident Sequence Report, or elsewhere, an explanation as to how the Staff or Licensee has determined that all of the necessary-TMI-2 related recommendations have been identified and that all the appropriate accident sequences have been addressed.

The-Board wants testimony or other evidence which explains,'if such be the case how the Licensee and the Staff have concluded that the NURIG-0578 short-and long-term recommendations, and other subsequent safecy recommendations, and the identified accident sequences (with their respective preventative or mitigative measures) are in their totality sufficient to provide reasonable assurance that TMI-2 can be operated without endangering the health and - safety of the public.

The question is not intended to enlarge the scope of the hearing.

The response may be limited to consideration of accidents following a loss-of-feedvater transient."

348.

Staff witnesses Ross and Japra made two basic arguments in response to this Board Question.

First, the witnesses conclude that because tne Action Plan grew out of the collective and comprehensive assessment by persons within and cutside the NRC having expertise in many technical disciplines, this pcovides reasonable assurance that the probable causes of the TA_ 2 accident and their associated corrective measures have been completely and adequately identified (Ross and Capra, ff. Tr. 15,555, at 5).

-349.

Secondly, the Staff concludes that " general agreement"

}

as to the causes of the accident and the areas where improvement should be made provides further assurance that "all significant deficiencies related to the accident have been identified in the Action Plan." (Ross and Capra, ff. Tr. 15,555, at 5).

g 350.

In summary, the Staff bases its assurance that the Action Plan contains all areas needing improvement as a' result of the TMI-2 accident on the process that was used to arrive at the Action Plan (Ross and Capra, ff. Tr. 15,555, at 11).

The same A=

-. e o m.

n.

m e

-148-L holds true for the assurance.that surrounds the necessity and sufficiency of the items in the subset of Action Plan items that the Staff has determined are requircd for implementation by the Licensee prior to restart (Ross and Capra, ff. Tr.

15,555, at 11-12).

351.

The Staff furcher argues, that having used the process of arriving at the Action Plan, and having taken what it describes as a " broad approach" to accidents with nexus to TMI-2, that this " obviated the need for a probabilistic assessment screening to focus on partibular sequences." (Rosenthal and Check, ff. Tr. 11,158, at 16).

352.

In both cases, in arriving at the set of, actions and recommendations that comprise the Action Plan, and in arriving at the set of sequences that compriss the ~*aff's judgment as l

to accident sequences with a reasonable nexus to the TMI-2 accident, it is the Board's conclusion that the Staff has 9

exalted form over substance.

Nowhere in the record of this' -

j proceeding is there evidence that the Staff has undertaken'a ij systematic evaluation of the TMI-2 accident and accident seguences with a reasonable nexus, and evaluated alternative recommendations 1

as to their ef fectiveness in meeting the concerns rai. sed by the TMI-2 accident, nor is there evidence in this record that the Staff has systematically identified both all the areas which recuire improvement as a result of the TMI-2 accident, and the necessary degree of improvement.

Indeed, once the various investigations of the TMI-2 accident were completed, it was n

-149-

, tho'NRC Stoff which controlicd which recommtndations wsv.o highlightsd what measures were presented to the Commission to address these recom a t, 4,

and-the priority given to'these measures and recommendations.

The Staff's indelible imprint is found throughout the Action Plan.

N where in the record, or~elsewhere for that matter, is there the sligh suggestion that the Staff has attempted to have the various investiga bodies (or members thereof) evaluate the specific measures recommende by the Staf f to address the concerns raised by the investigators. and comment on them.

353.

Even the Staff's characterization of what disagreement it i willing to acknowledae regarding the Action Plan displays an attitude favors form over substance.

The Staff testified, "Where differences i opinion occurred, they most of ten related to the degree of improvemen-required and 'the best method of achieving that improvement. "

(Ross a:

Capra, ff. Tr. 15,555, at 5)

The Staff's testimony on this matter co:

veniently avoids any discussion of disagreements within the Staff.and disagreements with persons outside the Commis; ion, as if the substanc.

}

of their disagreement (i.e., disagreement over how much improvement 1:

necessary and the best manner in which to achieve that degree or imprc ment) made that disagreement somehow unimportant or as if the manner :

which the disagreement was dealt with somehow was more important than the substance of the disagreement, i

354.

It is worth noting, in connection with Board Question No. 2 i

that the Licensee presented no testimony on this key issue, despite ar I-express invitstion from the Board to do so.

Moreover, Licensee's cror examination of the two Staff witnesses was aimed exclusively at testir 1.

I the n[c,gysity of certain of the Staff's recommendations, while failing

(

[

address the issue of the sufficiency of the recommendations.

(See, T+

15,637-15,740)

I

l

~

-lau-

.355.

The Board now moves to the issue of the sufficiency of the.

recommendations, i.e.,

the " fixes" (to use the Staff's term), which were recommended in the Staff's core damage accident sequence report.

We must consider whether these measures are sufficient to move TMI-related Class 9 sequences from the " credible" back into the realm of the "in; dible."

Before addressing the specific recommendations, the Board will address the general approach taken by the Staff in making recommendations for changes to be made as a result of the TMI-2 accident.

Past practice has been for the Staff to address accidents at the high-consequence end of the design basis (e.g.,

a double-ended guillotine break of the RCS) primarily by requiring the installation of emergency safety features (i.e., hardware changes),

although the Staff has also employed some procedural measu;es to mitigate DBE's.

Event sequences within the design basis (but not at the high-consequence fringe) have been " fixed" by the Staff primarily by requiring increased surveillance and testing of equipment, improved plant procedures, improved operator training, and some~hardwar requirements.

The goal of these " fixes", according to the Staff testimony, is to reduce the probability and/or the consequences of i

j.

an event sequence.

Selection of the means to implement one or more of the " fixes" is based in part on risk assessment, but predominately on " engineering judgment."

(Rosenthal and Check, ff. Tr. 11,158, at 18).

For accidents within the design basis, the assumption has presumably been that if operator action or procedures fail, there are engineered plant safety systems to mitigate such events.

356.

However, there are no safety systems designed to mitigate accidents beyond the design basis.

In addition, the occurrence of a Class 9 accident by definition implies the failure of safety systems

+-

...A ne frs m e

a. &_. m w m.. e

-151-either through mechanical malfunction or operator action.

Despite th fact that-Staff practice has beenLeo address accidents at the limit a the design basis primarily.by requiring hardware modifications, the Board finds:upon examin'ation of the " fixes" proposed by the Staff to address the first accident beyond the design basis-that most of the

" fixes" are related to operator training and procedural modifications The. record in this proceeding does-not establish the degree of gain i.

safety, either in terms of reducing the ' probability of accident se-quences of reducing the consequences of the accia-at seguences, from such procedutal and training modifications.

357.

In fact, the Staff testified that it could not quantify such gains which occurred principally in the " human regime".

(Tr.

11,251, Rosenthal)

The Staff was very reluctant to place any quanti-fiable terms on the probability of cperator errer, and, indeed, the Staff found it as difficult to correct operator action as.it did to place numbers on the probability of operator error.

(Tr. 11,235-36, Rosenthal and Check)

The Staff testified that it had included'operatt ferror in the core damage sequence report, but that the inclusion was implicit since the report did not distinguish the cause of hardware e

failure (either mechanically - or operator error - induced).

Signific.

ly, by so considering operator error, the Staff ecuates the probabilit of and the results of operator error with mechanically-induced hard-ware failure.

There is absolutely no evidence in this record which i

justifies such an assumption.

There is no record in this proceeding of the likelihood and consequences of operator action or inaction.

e a

4

-152-

-358.

Thus, the Board again arrives at a critical

-point in.the Staff's " methodology" regarding the determination of " credible" and "not credible" accidents and the determination uof -the sufficiency of the " fixes" proposed to deal with such accidents, and'again the Board finds the Staff relying implicitly on probabilities crithout having erobability numbers or actual calculations to back up the Staff's judgment of what the probabilities are.

The Staff relies upon~its judgment as to the selection of " fixes", again without any apparent systematic consideration of the relative worth of the fixes in improving the safety of the plant or reducing the consequences of the accident sequences.

In fact, the Staff acknowledges that not only is the record incomplete from the standpoint.

of describing the benefits of the proposed " fixes", but the.

record is also incomplete from the standpoint of describing

~

the potential risks associated with even what is presumed to be an improvement (Tr. 11,189, Check).

The issue of the

" potential risks associated with even what is presumed to be an improvement" has not been addressed at all in this proceeding by either the Staff or the Licensee.

t.

e 9etuhe M alhe e e e em 4

  • M@

_6

$s M-

_M N C &

,p & m.m..

Asa-359.

The hardware changes proposed by the Staff are as follows (Rosenthal~and Check, ff. Tr. 11,158, at 14-15):

A.

Main feedwater

--none B.

Emergency feedwater

--automatic initiation

--modification of EFW control valves

--automatic block loading of motor driven EFW pumps on diesels

--indication of EFW to each steam generator

--indication of EFW supply water

--automatic feed only to good steam generator logic

--future separation of EFW from ICS C.-

Primary pressure relief requirement

--raise relief valve setpoint and reduce high-pressure reactor trip setpoint

--anticipatory trip for loss of feedwater and turbine trip Primary system pressure relief and primary D.

system integrity.

--testing of reflef and safety valves

--direct indication of valve position

--emergency power to relief and block valves and associated instrumentation control E.

Emergency coolant injection (ECI) and Emergency coolant recirculation (ECR)

--subcooling meter

--instrumentation for inadequate core cooling (full implementation by January 1982)

F.

Post accident ralioactivity removal (PARR) and post-accident heat removal (PAHR)

--none 360.

The Board believes that even for these limited j

hardware changes as defined by the Staff there are substantial considerations involved which the Staff did not address.

First, upon reading the Staff's core damage sequences report (NRC Staff Ex.~3), it becade clear that the post-accident radioactivity w

a

n

-134-removal (PARR) and post-accident heat removal (P AHR) are both crucial functions.

PARR removes radioactivity from the contain-ment atmosphere fbilowing-an accident (via the reactor building spray system) ;- failure of this system does not effect the condition of the core, but does affect the severity of the consequences of the accident (NRC Staff Ex.

3, at 3, 8, 11).

~

PAHR removes core decay heat from the containment to prevent overpressure of the' containment (via the reactor building. spray pumps or the reactor building air cooler units) ; failure of PAHR leads ultimately to containment failure in several of the LOCA sequences presented in the Staff report (NRC Staff Ex. 3, at 5, 8,

11, 16, 21, 26, 31, and 36).

The Board notes that the Staff has proposed no hardware modifications whatsoever to these systems as a result of the TMI-2 accident, despite their obvious safety significance add impact on the public health and safety.

The Staff is apparently relying on procedural changes and operator training to address these f

concerns, yet the Board cannot find a single reference to any operator training or procedural changes which specifically,"

affect these two vital functions.

The Board can find no basis in the record for concluding that the changes proposed by the Staff and the Licensee will improve either the capabilities of these functions or the reliability of these functions by any degree whatsoever.

361.

Secondly, not a,ll of the hardware changes associated with Item D in Finding 42, suora., are, in reality, hardware changes.

As the Staff testified, certain of such changes must be 6.*

-J

_...e

n. -

m-

~

-155-s 6

concidar:d to be changes in the " human regime", namely the provision of direct' indication of valve-position.

This. change does not alter the probability of failure or success of the

' valve ~in performing ics function, but rather provides more accurate information to the plant operator.

The Staff testified that such improvements must be~ considered as a " human'fix" because "you don't know what he [the operator) is. going to do with that."

The Staff could not quantify the benefit of such

.Improvements (Tr. 11,251, Rosenthal).

The Board also notes that the testing of relief and safety valves will not be completed until 10/1/81 (according to the implementation schedule set.forth in NUREG-0737 and in Staff Ex. 13, at 10).

In addition, block valve testing is not scheduled for completion until,7/1/82 (ibid., at 10).

Even these completion dates are not _fidn ___

(Tr. 21,046, 21,048, 21,136, Silver).

362.

Similarly, there are other " hardware" changes,which upon second look are clearly within the " human regime".

These changes are instrumentation changes which provide additional information to th e plant operators, but do not alter in any j

way the capabilities of plant equipment or the performance of this equipment.

Changes in Finding 42, supra., which fall into the realm of changes in the " human regime" within this t

definition are, in addition to the example above, indication of I..;

EFW to each steam generator (Item B), indication of EFW supply tl water (Item B), subcooling meter (Item E), and instrumentation for inadequate core cooling (Item E).

I f

S W'19 m em 6-A g,

em e.

em WeDTa

-156-363.

.Regarding the " instrumentation for inadequate core cooling" under Item "E"~in Finding No. 42, supra., it is not at all clear that the full implementation date of' January 1982 will be met, since the Licensee has not made reasonable progress toward identifying or design.

such an instrument.

In fact, it is nearly certain that it will not be met.

Licensee is opposed to'the installation of any additional instrumentation for the detection of inadequate core cooling, taking the position that the installed instrumentation, together with additior training, is sufficient both for the short-term and the long-term (Keaten et al.,

ff. Tr. 10,619).

The Board understands this to be a consistent position with regards to Babcock and Wilcox NSSS owners.

364.

The Board now turns to the specific " recommendations for improvement" made by the Staff which are claimed to reduce,the likeli-hood of the core damage sequence accidents identified by. the Staff, pushing them back to the incredible req 1m.

Table 7 in the Staff's Report (NRC Staff Ex. 3, at 42) lists 14 actions purportedly proposed by the Staff to increase the reliability of the feedwater system by avoiding loss of main feedwater.

The Board notes first of all that there have been no hardware changes directed toward decreasing the probability of main feedwater failure.

(Rosenthal and Check, ff. Tr.

11,158, at 14)

The first recommendation cited by the Staff is the completion of the ICS failure modes and effects analysis.

The Board has already dealt at length on the problems inherent in the ICS relia-bility analysis performed by B&W [See, Proposed Findings of Fact and Conclusions of Law on Plant Design Issues, Steven C.

Shelly, 6/1/81].

The Staff also cites items 1-13 on Table 16 (NRC Staff Ex.

3, at 78-79)

However, items 1, 3, 11, and 12 are not requirements, having been deleted from TMI

-V%hes

-Lot

~ Action plan requirements in NUREG-0737.*

Item 12 has apparently been implemented by'the Staff as the SALP program (systematic assessment of licensee performance), but there is no evidence

'in the record as to the purposes, procedures, or effectiveness of this program and, therefore, the Board can assign this program-no weight in evaluating the effectiveness of this recommendation at reducing' the probability for loss of main feedwater.

More-over, what little evidence on this matter which is in the record suggests that SALP is a very general program with at best a tangential relevance to reducing the probability of loss of feedwater transients.

Item 2 in Table 16 (operational quality assurance program) requires no licensee submittal; additionally, the Staff's evaluation of this matter is not yet complete (NRC Staff Ex. 13, at Enclosure 1).

Item 1 (requirement for review of operating experience) is also an area of incomplete Staff review (NRC Staf f Ex. 13, at 6).

Virtually all of the recommendations with regards to reducing the probability of LOFW transients deal with operator training, review of operating experience, and additional procedural changes.

It is unclear what degree of improvement is expected from these changes, and f

the Staff makes no effort to. quantify this improvement.

In l

fact, all the Staff cot ld do was make a general argument thar improvements were made, noting however that the degree of improvement could not be quantified "in a manner that is sensible."

(Tr. 11,251, Rosenthal)

This is an insufficient basis upon which to conclude that otherwise credible accidents are now incredib These items are: review of operating experience, verification of adequacy of management and technical structure, requirement for onsite safety engineering group, and NRC's systematic evaluation of licensee safety.

)

\\

-158-365.

Table 8 in the Staf f's.. report deals with measures to " Reduce Potential for Failure of Emergency Secondary Heat Removal Function" (NRC Staff Ex.

3, at 46-49).

Again, Item 1 on the list is the ICS FMEA.

Remarkably, two key measures cited here by the Staff are Items 5 and 7, the IREP program and the resolution of Unresolved Safety Issue A-17.

IREP is a program whose benefits, whatever they will be, will accrue at best at some undefined date in the future.

There are no plans to include TMI-l within the IREP program at any time.

(Tr. C709-10, Conran)

Regarding systems interaction (A-17), the Board can find no evidence which suggests that any prog ress is being made in this matter; in any event, this, too, is a 'ong-range matter.

TMI-1 is.

not part of the 1:FEP program and there are now no plans whatever to do any systems interaction study for TMI-1.

(Tr. 8685-90, 8709-10, Conran)

Manifestly, this Board cannot give any credit for these measures or assume that they contribute :anything to. reducing the risk of accidents.

366.

Table 8 also references numerous items from Table 16'(NRC Staff Ev=

3, at 78-82), which is entitled " Generally Applicable Measures to Reduce the Potential for Safety Functions Failure."

The Board J

was presented with no evidence on the applicability of these measures to preventing emergency feedwater function failure.

A number of the recommendations in Table 16 are no longer requirements for TMI-1, despite Staff testimony that all of the recommendations in Table 16 apply to TMI-1.

(Tr. 11,275, Rosenthal)

Items 3, 11, 12, 24, 25, and 31 in Table 16 are not listed in NUREG-0737, and are therefore not required.*

Item 3-(verification of management and technical capability);

Item 11 (requirement for onsite safety engineering group);

(continued on next page)

-159-Some of the items in Table 16 appear on their 367.

face to have at best tangential relevance to avoiding loss

'of emergency feedwater (i. e., Items 3, 4,

9, 11-13, 21-24, 26, 27, 29, and 30) $*

The Board has been presented with no na Item 3 (verification of management and technical capability);

Item 4 (verification of adequacy of safety review and operational advice); Item 9 (shift manning requirement for emergency situations); Item 11 (requirement for onsite safety engineering group) ; Item 12 (systematic assessment of licensee safety); Item 13(shift technical advisor);

Item 21 (small break analysis); Item 22 (onsite technical support center); Item 23 (onsite operational support center);

Item 24 (simulator requirements); Item 26 (revisions to licensing examinations); Item 27 (control room access procedures); Item 29 (requirement for definition of shift supervisor responsibilities); and Item 30 (requirement for review of shift supervisor duties) are not clearly related to emergency feedwater, and the Board was presented with no evidence demenstrating such a relationship in the '

absence of an obvious link.

'I (cont) Item 12 (systematic assessment of licensee safety); Item 24 (simulator requirements); Item 25 (long-term program for

{

improving plant emergency procedures); and Item 31 (require-ment for plant drills in emergency procedures) are not included in the requirements set forth in NL'

~~0737, and cannot be considered applicable to TMI-l and cannot be i

accorded any evidentiary weight whatsoever.

+

6

-160-s evidence on.the degree of improvement expected from these

-recommendations.

368.

Further, the Board notes Licensee's own admission that even the conversion of the emergency feedwater system to safety-grade will not substantially alter the reliability of emergency feedwater since the principal deficiencies are in the environmental qualification of equipment for non-LOCA events (Capodanno, Lanese, and Torcivia, ff. Tr. 5642, at 11).

Licensee's own testimony is in conflict on the degree of improvement to be expected from modifications to the emergency feedwater system, since Licensee's Class 9 accident witness Mr. Levy testified that he expected improvements to result in a reduction in frequency of loss of feedwater (and therefore a reduction in demand for emergency feedwater, leading to a reduction emergency feedwater) by a factor in frequency of lose 6

of 2 to 3 (Levy, ff. Tr. 11,049, at 14).

The Board easily i

i i

resolves this conflict, however, since Mr. Levy's figures are based on WASH-1400 probability results (Tr. 11,130, Levy) and his own probability figures are " based on engineering l

judgment, on some rather quick assessment of a probability type of calculation, but not, you know, considerable detail type of studies.

It was just done on a gross basis, and as indic0ted. there, there are some uncertainties in the numbers."

(Tr. 11,091-9 2, Levy).

The Board does not regard Mr. Levy's probability estimates as reliableI

~~

l l

~

-161-369.

'In examining each of.the Tables purporting to identify

-measures sufficient to reduce the likelihood of.each accident in the

-Staff's core damage accident sequence report, the Board finds proble

.similar.to those. described above.

It would appear that the Staff has done little more than compile a list of items which were at some point.being. considered for implementation on operating reactors, withcuc. distinguishing the important from the less important recomme dations, without indicating what degree of improvement is associated with each and even without deleting those items not adopted for implementation.

The Staff then claims that these measures, in their undifferentiated entirety, will reduce the probability of TMI-2-rela accident sequences to the realm of being "not credible.",For the

. Board to come to such a conclusion would require a considerable leap of faith.

370.

In evaluating the so-called " recommendations" which were proposed by the Staff to mitigate the core damage sequence accidents the Board found numerous examples of recommendations wnich have sinct been eliminated as requirements, examples of recommendations which bear no obvious relationship to the event for which they are propose as mitigating measures, and recommendations which will' not have any short-term benefit.

371.

Examples of recommendations which have been eliminated as requirements (not listed in NUREG-0~ 37) includ :

a. Table 12, Item 6, IREP.
b. Table 12, Item 8, systems interaction -- resolution of generic safety issue.
c. Table 13, Item 4, correction of welds in safety-related i

systems.

d. Table 15, Item 7, LOFT research program on ECCS functior 372.

Examples of recommendations which are not obviously relatec

.-w

I

-162-

)

to the failures for which they are proposed to mitigate include:

a.

Table 14, Item 4, correction of defective welds in containment spray, alleged to improve ~ post-accident heat removal, b.

Table 16, Item 3, verify management and technical capability, alleged to improve primary system pressure relief capabilities, protect primary system integrity, prevent emergency coolant injection failure, prevent post-accident radioactivity removal failure, prevent post-accident hear removal failure, and prevent emergency coolant recirculation failure.

c.

Table 16, Item 4, verify capability of safety review and operational advice, alleged to improve the same areas as example "b" above (except for prevention of emergency coolant injection failure).

~

d.

Table 16, Item 12, systematic assessment of licensee safety, alleged to improve primary system pressure relief capabilities, protect i

primary system Shtegrity, prevent emergency coolant injection failure, prevent PARR failure, prevent PAHR f ailure, and prevent ECR failure.

e.

Table 16, Item 27, control room access procedures, alleged to prevent PAHR failure, prevent emergency feedwater function failure, prevent ECI. failure, and prevent ECR failure.

373.

Examples of recommendations which do not have any short-term benefit including:

l a.

Table 10 and 11, Item 1, safety and relief valve testing program.

b.

Table 12, Item 5, long-term ICC instrumentation.

c.

Table 12, Item 6, IREP.

d.

Table 12, Item 7, LOFT research program on ECCS.

e.

Table 12, Item 8, systems interaction study--

l resolution of Unresolved Safety Issue A-17.

f.

Table 16, Item 24, simulator requirements.

g.

Table 16, Item 26, revisions to licensing examination.

=

mm 4 m muse

- ese Q D..*

u

^-

w

-163-374.

We have found the whole concept of credible vs. incredible as it is used either explicitly or implicitly for purposes of determi:

the design basis to be an elusive and troubling one.

The Board was frankly astonished that the Staff has apparently never been called upon to justify its practice before, nor has it apparently ever attempted to apply anything approaching a rigorous analytic technique to its design basis determinations.

The first effort at a justificati of its practice was presented to this Board.

375.

In summary, the staf f has no quantitative or even clearly elucidated qualitative measure of the likelihood of Class 9 TMI-related accidents before the implementation of the post-TMI-2 improve-ments".

Likewise, it has no measure of the degree of improvement which can be associated with the post-TMI-2 improvements.

It knows neither where it started nor where it has progressed to.

Perhaps the only hard evidence in this case which reflects directly on the reliability of the staff's judgments with respect to the probability j

of accidents beyond the design basis is the fact that TMI-2 was

'tj such an accident and that the staff judged it to be incredible until it happened.

This does not give us grounds for confidence.

376.

Despite knowing neither where it started nor where it has j

progressed to, the Staff asks this Board to accept the proposition that all TMI-related accidents beyond the design basis are now in-credible.

This record does not support such a finding.

Indeed, it would be irresponsible for this Board to make a fi;' ng of such great consequence and precedential value on the basis of the evidence-before us.

m

^_

l

-164-

+

377.

In summary, the Board finds:

The Staff has,no probability numbers fo.any a.

accident sequence, and does not therefore know the likelihood of any accident sequence.

b.

The Staff has no scrutable, technically justifiable method-for classifying accidents as credible or not credible.

The Staff implicitly assumes an understanding c.

of probabilities, which understanding has no factual or technically justifiable basis, d.

The Staff has made no showing that it has identified all of the credible accident sequences with nexus to the TMI-2 a'ecident.

e.

The Staff has made no showing that it has" identified all of the necessary and sufficient recommendations for changes which will adequately protect the public health and safety from the consequences of accidents with a nexus to the TMI-2 accident.

378.

M reover, in response to a spec,ific direction from the Board to address the issue of the probability of the TMI-2 accident sequence (and those with close nexus)',

as embodied in the Board's June 23, 1980, Memorandum on NRC Staff Accident Sequences Report,.neither the Staff nor the Licensee attempted a showing even approaching what the Board requested. UCS has prevailed on its Contencion No. 13.

m

-165-379.

Based upon all of the foregoing, the Board conciudes that the short and long-term actions recommended by the Director of NRR are not sufficient to provide reasonable assurar.:e that TMI-1 can be operated without endangering the health and safety

~

of the public in that they'do not ensure againtc the recurrence of a TMI-2 related accident beyond the design basis for'TMI-1.-

4 O

e e

I.

il il i

d%

4 S

4 T

1

~

i

'1 D.

9 -

-, y e

oe me.

-e-y,

-#=

--w

,,,,.,-..,e

,e

-166-BOARD QUESTION NO. 6 The Board posed a series of questions aimed at 380.

determining whether the decay heat removal systems at TMI-l are suf ficiently reliable to permit restart without (Board Question undue risk to public health and safety.

2394-96) 6, Emergency Feedwater Reliability, Tr.

We address below the applicable TMI-2 lessons 381.

the TMI-l decay removal methods, the Licensee's

learned, testimcay, and the Staff's testimony.

l I

EFW Lessons Learned The need for an emergency feedwater system of high l

382.

l, reliability is a clear lesson learned from the TMI-2 1

ll accident.

(NUREG-0 57 8, at 10) lI In recent design reviews since the issuance of 383.

the auxiliary feedwater system the Standard Review Plan, is treated as a safety system in a pressurized water is required to satisfy the decay reactor plant.

'I t forth in General Design removal requirements set heat It also Criterion 34 of Appendix A to 10CFR Part 50.

role in the mitigation of feedwater plays a significant l

t e

x

-167-b transients, which are anticipated operational occurrences.

p (Id., at A-30)

General Design Criterion 20 of' Appendix A to 10 CFR 384.

Part 50 requires, in part, that the protection system shall be designed to initiate automatically the operation of appropriate systems to assure that specified acceptable fuel design limits are not exceeded as a result of antici-l pated operational occurrences.

~

50 defines and explains 385.

Appendix A to 10 CFR Part anticipated operational occurrences as "those conditions of normal operation which are expected to occur one or more times during the life of the nuclear power unit and include but are not limited to loss of power to all re-tripping of the turbine generator set, circulation pumps, isolation of the main condenser, and loss of all offsite power.

TMI-l Me3 hods of Decay Heat Removal P

In the event of an anticipated operational occurrence 386.

such as a main feedwater transient or a loss of all offsite-power, the TMI-l systems initially available for decay heat removal are the emergency feedwater system and in conjunction with the high pressure injection system, the PORV or pressurizer safety valves, operating in the 1:

t

=

, - - - + -

-. ~

-168-feed and bleed cooling mode.

(Keaten, et al, ff. Tr.

. 16,552, at 6-8 ).

387.

Af ter the reactor coolant system has been cooled

~ and depressurized to about 250' and 320 psig, the low pressure injection system (also called the decay heat removal system) can be used to continue the cooling process until the conditions of cold shutdown (reactor coolant system average temperature less than 200*F) are reached. (Id., at 5, 9)

Licensee Testimonv i

The Licensee has performed no evaluation to determine 388.

the probability of loss of main feedwater at TMI-1.

However, the generic data for B&W plants over a two year period for five plants (i.e., 10 unit-years) shows that the frequency of loss of main feedwater was 0.3 per plant-year.

The Licensee 1

i estimated that the uncertainty attached to this frequency is less than a f actor of 10.

(Tr. 16, 618-2 0, Keaten)

This represents a high probability of loss of main feedwater and a consequently high rate of demand for emergency feedwater.

389.

The Licensee also does not know either the proba-bility of failure of the emergency feedwater system or the probability of f ailure of all decay heat removal system at i

TMI-1. (Tr. 16,629, Keaten)

S x

-- - ~ -

e.

.,,,-,,-.,e

,,,-r e, -,

e

.-,--r

-169-I 390.

The Board inquired into the protection provided by the l

emergency feedwater system in the event there is a loss of steam in the secondary system which results in failure of the turbine-driven pump.

(Soard Question 6.g.)

391.

The Licensee testified that if only one motor-driven pump is available initially, reactor coolant system temperature and pressure would initially increase, possibly resulting in lifting a relief valve.

(Keaten, et al, ff. Tr. 16,552, at7 )

392.

It must be emphasized that the pertinent lesson learned requirement was that "the auxiliary feedwater system initiation time and capacity and the reactor scram time should be such that the water levels in the steam generators being supplied, following loss of main feedwater flow,' remain high enough to provide sufficient heat transfer capability to remove stored and residual heat without causing opening of the primarv coolant system relief and code safety valves."

(NUREG-0578, at A-30, i

emphasis addedl l

h 393.

We conclude that the TMI-l design does not meet this l.

requirement in that loss of one motor-driven pump does not leave suf ficient EFW capacity available to prevent opening of the PORV or safety valves.

I 394.

The Licensee, under cross-examination, agreed that use of the EFW system for decay heat removal relies upon the l

-170-operation of other non-safety grade equipment such as the atmospheric dump valves, the turbine bypass valves, and/or the main condenser.

{Tr. 16,557-59, Keaten)

There is no way to remove decay heat from the steam generators without the use of non-safety grade equipment.

(Iji. )

This intro-duces an inherent unreliability into the system.

395.

The reactor operator is relied upon to manually control steam generator level.

Automatic control of steam generator level is provided by the non-safety grade integrated control system, but not at a sufficiently high level for adequate heat removal in the two phase mode natural circulation.

(Tf. 16,561-62, Ross) 396.

The Licensee hes not done a duantitative reliability analysis of the feed and bleed cooling.

(Jones, ff. Tr. 4589, at 3) 397.

The feed and bleed cooling mode cannot be used to achieve cold shutdown conditions.

(Id., at 2) 398.

For some break sizes, a minimum of two high pressure in-jection pumps are needed for feed and bleed cooling.

(1d.,

at 3) 399.

Feed and bleed cooling cannot be terminated unless main or emergency feedwater is restored or the PORV is used to depressurize the reactor coolant system to allow operation m

r

-171-r of the decay heat removal system. (Tr. 16,574-75, Ross) 400.-.There is no nathod available by which TMI-1 can be taken from hot shutdown conditions at normal temperature and U

pressure to either cold shutdown conditions or the conditions necessary to allow operation of the low pressure injection system using only safety grade equipment.* (Tr. 16,557-59, Keaten; 16,574-75, Ross; Tr. 16,583-85, Keaten) 401.

The Licensee also testified that use of a new vent valve on the top of the pressurizer could be used to depressurize the reactor coolant system in case the non-safety grade PORV fails.

(Tr. 16,57 5-7 6, Keaten) 402.

However, this vent will not be installed prior to the planned restart date in late 1981. 1(S taf f. Ex. 14, at 52-53)

Therefore, we can give no credit for it.

i 403.

In the feed and bleed cooling mode, the pressurizer safety valves may have to cycle open and closed, but the Licensee did not know whether the qualification testing of the Pony and safety valves will include such operation.

(Tr. 16, 5 8 0- 81, Keaten and Colitz) 404.

The Licensee has not reviewed the initial test program

. i for the high pressure injection pumps to determine whether they Regulatory Guide 1.139, the provisions of which are'appliec oy staff to pending applications, requires a demonstration that the plant can be taken to cold shutdown using only safety grade equipment, assuming a single failure, with only on-site power, from the control room.

The Division of Safety Technology has requested-the Division of Licensing to develop a plan.for imple-a plan has not menting this position on operating reactors, but 4

yet been proposed for this.

(Tr. 8079-8081, Silver) 9 s

e e

-r-,

,-me m

-172-1 i:

j

are qualified for long term operation at a discharge pressure l

of.2500 psig.

Instead, Licensee relics on the original design specification for the pumps and the belief that someone must have looked at the original qualification tests before issuing the feed and bleed operating guidelines.

(Tr. 16,582-83, Colitz and Ross)

No one who had " looked" was offered or even identified.

Under these. circumstances, such testimony can be given no weight in the Board's consideration.

L 405.

In summary, the Licensee presented no convincing evidence that it had made a serious attempt to assess whether the reliability of the methods for decay heat removal is sufficiently-j high to justify restart in light of the lessons -learned from the TMI-2 accident.

Therefore, we must consider whether the Staff's testimony was sufficient to fill the void in the record.

d 1

Staff Testimony 3

1 406.

The Staff testified that it had performed a reliability 1

assessment of the TMI-l EFW system and concluded that the EFW system with the modifications to be Unplemented by the time of restart would be sufficiently reliable to allow restart of l

TMI-1.

(Wermiel and Curry, ff. Tr. 16,718, at 1)

There was substantial questioning about the basis for this conclusion.

407.

The Staff presented reliability estimates of the TMI-1 emergency feedwater system design as it existed in mid-1979 and as it will exist after planned changes are completed.

(Id., at 31)

In the latter case, the reliability estimate E

e a

n.

,w

-173-assumed that all of the long-term modifications had been completed.

(Tr. 16,733, Curry)

The Staff's analysis used failure rate estimates from 408.

WASH-1400.

(Wermiel and Curry, ff. Tr. 16,718 at 33-34, Tr. 16,962, Curry)

The Staf f analyzed three specific plant " transients" 409.

in the demand for EFW - loss of main feedwater, that result loss of offsite power coincident with loss of main feedwater, and loss of all AC power coincident with loss of main feedwater.

(Wermiel and Curry, ff. Tr. 16,718, at 32) the Staff To estimate the probability of EFW failure, 410.

least defined failure as failure to provide 460 gpm flow to at l2-one steam generator within five minutes.

(Id., at 31) 411.

Given a loss of main feedwater, the Staff estimated the for the mid-1979 design

~

probability of EFW failure to be 8X10 for the design after all long-term modifications

-4 and 4.5X10 1

are completed.

(Id., at 35, 37, and Attachment 3)

Given a loss of offsite power coincident with loss of 412.

the Staff estimated the probability of EFW main feedwater, failure to be approximately the same as given above for the loss of main feedwater.

(Id., at 35, 37) 413.

For a loss of all AC power, the Staff estimated the i

6X10 ' for the mid-probability of EFW failure to be aboit s

e

-W A

e

= ne mm

-174-1979 design and about the same for the design after all long-term modifications are completed.

(pi.)

The Staff also estimated that, for the loss of main feed-414.

-3 water _ transient, the probability of EFW failure is about 3X10 for the design as it will exist at the proposed restart date.

(Tr. 16,738, Curry)

The Staff did not present an estimate of the probability of EFW failure for the restart design for the loss of offsite power and loss of all AC " transients."

The Staff witness believed that his estimates were accurate l'

within an uncertainty range, of a f actor of 10.

(Tr. 16,9 65,

l.-

Curry) 1 relatively high failure rate estimates 415.

Thesa are, of course, particularly considering that theidemand rate for the emergency

.i t feedwater system is also high.

This is because EFW is required to remove decay heat for anticipated operational occurrences such as loss of main feedwater and loss of offsite power.

Loss of main feedwater has historically occurred at B&W plants at the rate of 0.3 per plant year.

(Tr. 16,618-20, Keaten) 416.

Thus, while it could conceivably be acceptable to tolerate lower reliability levels for safety equipment.which is called l

upon to function only very rarely, the evidence shows that emergency feedwater is needed perhaps once a year or within i

that range.

Given this demand rate, an EFW failure rate in Il 1

1.

!l 1

~mcm~

-175-the range which the staff presented is intolerable.

417.

Moreover, the failure rate is in fact higher than indi-cated by the staff.

The staff witness biased the results of his fault tree analysis by simply assuming that at least one of the diesel generators would function when called upon.

That is, he assumed that one diesel generator was available and the probability of failure of the other diesel generator

-2 was 10 (Tr. 16.971, Curry) 418.

UCS requested the Board to take official notice of the diesel generator failure rate estimates used in WASH-1400.

The estimate presented in WASH-1400 for failure of a diesel

-2 generator to start is 3X10 (WASH-1400, App. III, Section 2, I'

Table III 2-1)

We denied this requdst on the ground that the figures presented in WASH-1400 are not universally accepted.

We have reconsidered this ruling.

419.

We noted above that,the failure rates used by the staff were derived from WASH-1400.

We have also found in our review of the record that the Licensee has relied on WASH-1400 component failure rates in calculating accident probabilities.

(Eg, Tr.

11,107, 11,130, 11,140, Levy; Levy, ff. Tr. 11,049 at 14,15) 420.

In addition, we have reviewed the Appeal Board decision 9

f in Florida Power and Licht Co. (S t.

Lucie Nuclear Power Plant, f

Unit No. 2), ALAB-603, 12 NRC 30 (1980).

The issue in that l

e e

e,

-17'6-l procee d1ng centered around the likelihood of total loss of In that connection, one staff witness on diesel gen-AC power.

erator reliability used the WASH-1400 demand failure rate of 3X10 (Id., ' at 47)

The Appeal Board noted that this was

-2 an appropriate use of WASH-1400.

.(Id. at n.

60, p. 47)'

Based upon this figure, they determined that the probability

-3 of failure of both diesel generators is in the range of 10

-4 to 10 (pi., at 46)

Considering that the Licensee's objections to the Board's 421.

I taking official notice of the failure rate of diesels was

-general in nature and presented no facts suggesting that these and considering that the staf f has figures are inaccurate, 2:

itself used these figures in testimdny very recently, we see no reason why they cannot be officially noticed.

If the diesel generator failure rate were factored int'o 422.

the staf f's analysis, the ef fect would be to make the prob-ability of failure of emergency feedwater even greater, although the exact magnitude of the change cannot be determined.

Judging f rom the Staf f 's f ailure probability estimates 423.

it can be concluded for the loss of main feedwater " transient',

in EFW reliability that relatively little of the improvement attributable to hardware changes will be incorporated prior I

to the proposed restart date.

(Tr. 16,742-43, 16,746, Curry) l I

2 h-

~

r:

-177-

'424.

The StaffLattempted to downplay the-significance of the relatively high probability of EFW failure in two ways.

First, the Staf f claimed that if more time for operator action were considered, i.e.,

if the definition of EFW failure was changed to allow mo:te than five minutes to deliver flow to at least one steam generator, the estimated reliability of EFW would t

improve.

Second, the Stt ff claimed that the availability or the bleed and feed cooling mode could be recognized as a l

)_

backup to EFW for decay heat removal.

We now address these two factors to explain why such testimony cannot be given any I..

weight.

e 425.

The Staff acknowledged that it had done no analysis j 'o.

of TMI-l EFW failure probability fc.r a time interve.1 longer than five minuten.

(Tr. 16,744, 16,746, Curry) 426.

The Staff opined nonetheless that if a longer period of time were ancif zed (i.e., if the definitiCn of EFW failure allowed more time to deliver EFW to the steam generators), operator action could introduce additional failure modes, but that it was more likely that operator action would correct failures.

(Tr. 16,749, Curry)

However, that testimony was not based on review of the TMI-l emergency procedures or operator qualif-

]

ication training and is little more than speculation.

(Tr.

16,758-9, Wermiel)

I h

e.

a

..e m m

1 I

-178-l 427.

When the - Board (Dr. Jordan) asked the Staff to explain why Westinghouse plants have an order of magnitude higher f

'EFW system reliability than TMI-l (We:miel and Curry, ff. Tr.

1 16,618, at 35,37), the Staff attribu 2 this to the difference in the success criterion.

That is, since Westinghouse steam generators-dry out in the absence of EFW more slowly than i

TMI-1, much more credit can be given for operator recovery i

i action.

(Tr. 17,075-76, Curry) 428.

However, B&W did analyze EFW reliability for 5, 15, and 30 minute intervals, and in no case were the reliability

~

estimates as high as the best Westinghouse reliabilitiesi (Tr. 17,076, Curry)

Therefore, this record indicates that, even if the success ctiteria had bee.I loosened, no great improve-ment in EFW reliability would be demonstrated.

429.

The Staff made no attempt to analyze the longer time periods.

(Tr. 17,G76-77, Curry) 400. Nevertheless, the Staff's witness still testified that he " suspected" that credit for operator action would improve the reliability sufficiently that in his " judgment" the reliability could ' broach" the high range.

(Tr. 17,095, Curry) 431. We find such Staff testimony disturbing.

Despite the lack of any supporting analyses whatever and despite contra-dictory B&W analyses, the Staff apparently would have this

DS'

~

-179-Board rely on its feelings that the reliability of the TMI-1 EFW is not as low as the Staff's own analyse s it.dicated.

The evidence does not support such a conclu i s on.

432.

The other line of argument made by the Staff i effort to mitigate the relative unreliability of EF n an W was that the feed'and bleed cooling mode is avail bl a

EFW for decay heat removal.

e as a backup to (Tr. 16,847, Wermiel)

However, no analysis of the decay heat removal capability over an extended period of time for the feed and bleed mod e has beer.

reviewed by the Staff.

(Tr. 16,848, 16,873, Wermiel) 433.

Staff witness Jensen testified:

"We have not requested nor has Metropolitan Edison provided us with eith er procedures or analyses. for cooldown of the R actor Coolant Syst feed-and-bleed, nor have we performed such ev l em by a uations."

(Wermiel et al., ff. Tr. 6035 at 6) 434-We will not reiterate all of our previous findings on feed-and-bleed.*

One additional point should be noted Use of bleed-and-feed to mitigate anticip t d

, however.

ae operational occurrences has the effect of transforming such relatively We have previously determined that feed a reliable method of core cooling.

and bleed is not on UCS Contentions 1 and 2, parcel. (UCS Proposed Findings 36)

'r l

-160-i likely events into loss-of-coolant accidents, since primary ne cooling water.

system valves must be opened to "bleec" In addition, of course, ECCS must be used for bleed and feed.

It seems to us to turn the NRC's regulatory philosophy on its head to rely on bleed and feed for mitigating anticipated operational occurrences when General Design Criterion 14 requires an " extremely low probability" of LOCA's.

435.

The Staff also testified that to draw conclusions about the comparative risks of operating various nuclear plants, consideration needs to be given to the integrated response of all plant systems to cope with potential transients, not:

solely EFW.

This integrated response, while clearly affected by the reliability of individual sysiems, is also a function of systems interactions.

(Wermiel and Curry, ff. Tr. 16,618, at 39-40) the Staff has not done and is not planning to 436.

However, do, in the foreseeable future, such an integrated relability assessment for TMI-1.

(Tr. 16,732, Curry) 437.

Furthermore, the Staff has not done a systems inter-action study for TMI-l (Tr. 16,877, Wermiel) and is not planning to de one.

(Tr. 16,923, Rowsome)

The Staff's witness was unaware of the ACRS recommendation l

438.

the Licensee should conduct reliability assessments of that and was unf amiliar with any ACRS reports concerning the plant e

i

+

-l

-181-A the methods to be used in systems interaction studies. (Tr.

- 16,877, 16,883, Wermiel) 439.

Studies done on other plants have identified three potential common mode failures for B&W plants that could constrain the reliability with which a plant can deal with a loss of feedwater.

These are as follows:

(1) a loss of both onsite and'offsite AC power; (2) a loss of a NNI

- (non-nuclear instrumentation) bus whit:h could both cause a 1

loss of main feedwater and prevent au*:omatic flow from the EFW system; and (3).a failure in the steamline break detection i

circuitry which could result in isolation of feedwater to both steam generators.

(Tr. 16,913, 16,921-22, Rowsome)

Only the first of these conedrns has been corrected I '~

440.

at TMI-1.

There are plans afoot to address both the other concerns, but not until the first refueling outage after the proposed restart date.

(Tr. 16,922, Rowsome) 441.

UCS attempted to establish through cross-examination of the Staff that no criteria were used to decide whether any particular change to EFW was necessary as a prerequisite for TMI-l restart - that the Staff's " requirements" were not requirements at all, but were infinitely flexible and the Staff

. accepted as the bounds of its " requirements" whatever was practical for the Licensee to accomplish.

As discussed below, J

i we conclude that UCS successfully demonstrated this to be

~

the case.

.I' r

r p

-182-442.

The Staff could not identify any requirements applicable to the EFW system that it considered so vital that restart would not be permitted without meeting the requirement.

(Tr.

16,835, Wermiel) 443.

Even where the Staff acknowledged that a requirement was important enough to safety that TM -I should not be permitted to operate for the remainder of its lifetime without complying, the Staff was unwilling to state that failure to meet the j

requirement would require TMI-l to shut down.

(Tr. 16,836-37, Wermiel) 444.

The Staff witness was unfamiliar with the details of compliance with GDC-20, (Automatic initiation of protection systems functions), and did not knhw whether the initiation I~

circuits for EFW had to be safety grade in order to comply with GDC-20.

(Tr. 16, 8 6 0- 6 3, Wermiell*

~

445.

The Staff originally rejected the Licensee's proposal to delay installing a fully safety grade EFW system until the first refueling outage following restart.

When questioned Although the Licensee disputed the applicability of GDC 20 (automatic initiation of projection system functions) to the TMI-l emergency feedwater system (Tr. 5802, Capo-damo and Lanese), the Lessons Learned document, NUREG-0578, states:

"Recent analyses of primary system response to feedwater transients and reliability of installed auxiliarv feedwater systems establish the need for automatically initiating the auxiliary feedwater system, consistent with satisfying the requirements of GDC 20."

(Board Exhibit 7 at A-30).

The Staff apparently assumed the applicability of the criterion.

(Tr. 6058-6062, 16,860, l

Wermiel: Wermiel and Curry, ff. Tr. 16,718, at 9)

-183-about the reason for this, the Staff could not provide an explanation.

In fact,'the Staff testified that its original

" requirement", that the" fully safety grade modification of EFW be installed within 60 days af ter receipt of the required equipment, never held much weight because equipment delivery could be delayed until the refueling outage occurred.

However, the Staff acknowledged that at the time it imposed the 60-day installation requirement, equipment delivery was expected in March 1981.

The Staff believes that installation of a fully safety grade EFW system would provide a significant improvement in EFW reliability.

(Tr. 16,864-67,-Wermidl; Staff Ex. 1, at C8-37) 446.

However, the Staff's ;ositionbis now changed to agree

~

-with the Licensee's original proposal which the Staff had previously rejected.

The Licensee " commits" to installation of the safety grade EFW system by the first refueling after restart.

The Staff finds this acceptable based on the good-faith effort of the Licensee to obtain the required equipment and the fact that some other B&W plants have similar problems.

(Sta ff Ex. 14, at 38) 4 447.

The Staff witness did not know whether the EFW system i

l was seismically qualified or even if it has to be seismically qualified prior to restart.

(Tr. 16,894-96, Wermiel) u

=

w w

iv-

&--w m - - -

rr--

r-

-184-l The Staff witness did not.know if compliance with 448.

to control of EFW if access to the main GDC-19, with respect was required prior to restart and lf_

control room is lost, I

.did not-evaluate the TMI-1 design to determine the extent of compliance.

(Tr. 16,896-99, Wermiel)

We conclude, based on the Staff testimony described 449.

that the Staff's conclusion that the TMI-l EFW system

above, is sufficiently reliable to allow restart has no credible 1

basis.

In fact the staff did no plant-specific analysis of 450.

TMI-l as it will be at the time of restart in order /u3 deter-mine whether it is safe enough to restart.

(Tr. 21,117-19, Q:

It simply attempted to ascertain whether TMI-l Silver) was moving on approximately the same schedule as other similar B&W reactors.

(Tr. 21,042-44, 21,049-50, Silver; Staff Ex. 14, at 3)

This Board is required to determine whether the short-451.

term measures recommended by the Director of NRR are "necessary and sufficient" to assure that TMI-l can be safely restarted.

This record is abundantly clear that the staff has equated u.

" sufficiency" with pracricality.

That is, whatever can be done by restart is sufficient for restart.

(Tr. 21,044-21,050, Silver)

While we do not doubt that considerations of practicality have a place in the setting of regulatory w

a

-185-requirements, it must be a secondary place to considerations

. of safety.

" Safety first" is a principle which the Commission has espoused from its inception.

[ Power Reactor Development International Union of Electrical Radio and Machine Corp. v.

Workers, 367 U.S. 396,402 (1961))

is most troubling here is the total absence of 452.

What any objective criteria on the staff's part for determining the set of measures in place at restart are sufficient that to ensure safety.

453.

In addition, this record shows that virtually every post-restart deadline is waivable, nothing is so important to safety as to make a deadline firm and there is no assurance that any deadlines falling later thdn June 30, 1981 will not be changcd.

(Tr. 21,04 5-4 6, 21-136-37, Silver; Tr. 21,236, Jacobs)

Under these circumstances, there is no assurance that the long-term modifications, which include upgrade of EFW initiation and control to safety-grade, will be accomplished expeditiously.

Indeed, the record indicates that certain components required for the upgrade will not be available for two years.

( Staff Ex. 14 at 37; Tr. 21,052-53, Silver)

We note that this would appear to fall later than the next h

refueling outage after restart, suggesting that the modifications j

would not be made until the succeeding refueling outage.

l I

^

e

-=

=we m.

-186-454.

The Staff and Licensee argue that TMI-l restart should be permitted despite the fact that EFW will not be safety i

grade.. The following is a summary of the improvements which all parties. concede are required to the emergency feedwater system but which will not be accomplished by restart.

t 455.- Cavitating venturis to protect against steam generator overfill (and a resulting overcooling accident) will.not be installed.

The purchase order was expected to have been j

issued in May 1981.

(Staff Ex. 14, at 36,38)

The Staff had no explanation for why the purchase order had not been issued earlier and could identify no specific problem's to 4

account for the delay.

(Tr. 21,264-65, Jacobs) 0' 456.

The existing automatic circ 5its for opening the EFW control valves on an automatic initiation of EFW are derived from the Integrated control System which is not safety grade and therefore the automatic circuits do not meet the single failure criterion.

(Staff Ex. 1, at C8-36)

This violates the short term requirement that tha automatic initiation circuits shall be designed so that a single failure will not result in the loss of auxiliary feedwater q]

system function.

(Staff Ex. 1, at C8-34)

Nevertheless, the Staff argues that manual control of EFW flow can be used I

in lieu of the required automatic control.

(Staff Ex. 1, at C8-37) i i

r e ----. - -.e

, - + --e.-r,e-,-

~

c --

-187-457.

The Staff reportsithat the Licensee " commits" to the installation of redundant control and block valves by the first refueling after the proposed restart date.

(S taf f Ex. 14, at 38)

The' Staff did not investigate whether an earlier schedule is possible, and does not know the delivery i

date of -the valves or the type of valves.tcy be used.

(Tr.

21,265-67, Jacobs) 458.

Automatic initiatica of EFW from. low steam generator level detection is not installed and the-Staff has no estimate-

.of how long it will be before it-is installed.

(Staf f Ex.

14, at 3'; Tr. 21,267-58, Jacobs) f 459.

Safety grade steam generator level instrumentation

( *.

  • qualified to IEEE Std 323(1974) will not be installed prior to the proposed restart date.

(Staf f Ex. 14, at 37) 460.

The water supply for the EFW system comes fre":. the condensate storage tank but the existing condensate storage tank level instrumentation is not safety grade (Staff Ex. 14,

{

at 37) and both existing instruments are powered-from the same i

power supply (Tr. 17,003, Wermiel) and, thus, do not meet the single fpilure criterion.

Thus, we cannot find that d

the ErW system provides an equivalent level of protection to a safety-grade system.

461.

The Staff was unable to specify or even reliably estimate the.date-by which the emergency feedwater system upgrade will O

w'

---m--

e.

n_.ne, w

a,, m.=

mm

.ee. N --

..Am_

-188-l' be completed and the record indicates that the ultimate date o

will depend entirely upon considerations of expediency.

(Tr. 21,264-21,321, Silver, Jacobs and Jensen, particularly 21,318-21, Silver)

Board conclusions 462.

The Board has considered the state of this record on emergency feedwater reliability in light of the App'eal Board's decision in Florida Power and Light Co. (St. Lucie Nuclear Power Plant, Unit No. 2), ALAB 603, 12 NRC 30 (1980)

We note at-the. outset that the probability of emergency feed-water system failure is far greater than the guideline values in Section 2.2.3 of the Standard Review Plan for designating

-7 a particular event a design bas s accident - 10 per year

-6 calculated " realistically" or 10 per year calculated

" conservatively."

While, as the Staff points out, Section 2.2.3 applies on its face to external hazards such as ha:ardous material's (Wermiel et al.,

ff. Tr. 6035 at 10), we have been presented with:no convincing reason why these valves cannot or should not be used as a starting point

-in determining the risk level _ acceptable for other situations, as the Appeal Board used them in St. Lucie, supra at 45.

i l

Moreover, neither the Licensee nor the Staff have presented to us any alternative,-objective criteria for use in considering

-the reliability of the emergency feedwater system.

O l

I

-189-463.

There is, in addition, at between the situation present d least one significant differen e

ce record which strengthens our vie in AC.AB-603 and the curr ent w that to use objective, quantitati it is appropriate here ALAB-603, ve reliability criteria.

the Appeal Board specificall In the pertinent General Desig y found tha t GDC 17, of offsite power, was met by the An Criterion governing y

pplicant.

In the case of the TMI-l EFW (Id. at 44)

GDC defining a system, at lenst some of the safety grade emergency feedwat not be met at restart, er system will and control) particularly GDC 13 and GDC 20 (ins trumen ta tion (automatic initiation) 6063, Wermiel).

(Tr. 9058-

Also, order to provide 10 minutes forthe cavitating venturis r red in overcooling will not be install dopbra tor action to mitigate e

at Wermiel) restart.

(Tr. 6062-6, See the discussion, supra paras.

464.

Thus, this is not 454-461.

reliability assessment simply a situation where a quanti regulatory requirements. indicates a need to go b tative eyond current ment in combination with the noThe quantitative reliability assess-emergency feedwater n-safety grade status of the system at restart level of system demonstrate an overall We add that reliability at restart which is in our view, unacceptable.

finding that the record also does not the system will be acceptabl justify a the fuel upgrade.

In the latter case, y reliable even after after emergency feedwater

^

m-

-190-t L

is' safety-grade this situation is more directly analogous to St.'Lucie.

We note that the record shows, perhaps surprisingly, l-that safety-grade emergency feedwater systems are not histor-l~

l ically significantly.more reliable than others.

(Tr. 6106-7, i.

Lantz)*

465.

Another difference between St. Lucie and this case

!i which appears pertinent to us is that the issue under consid-l-

I eration there - the extent to which " station blackout" should be considered in plant licensing - was the subject of a staff " Task Action Plan."

(pi at n.

55, p. 4 6)

Indeed,

~

in accepting review of the issues presented by ALAB-&O3, the Commission limited its review to only two " generic" 9'

issues:

1) the generic implicatibns of using the SRP S2.2.3 guideline valves for determining design basis events and
2) the appropriateness of designating station blackout as a design basis accident given the pendency of the staff Board Question 6C asked for "the experience in other power plants with failures of safety-grade emergency feedwater systems..."

The Licensee apparently misconstrued the question, since it presented statistics only for B&W l

plants, without distinguishing between those which have safety-grade EFW systems and those which do not.

(Capodanno-et al., ff. Tr. 5642 at 5-6) only one of the plants -

Davis Besse - has a safety grade system.

(Tr. 5745-6, I

Capodanno)

The Staff testified that, considering only safety-grade emergency feedwater systems, there have been 8 instances of EFW unavailability in 200 reactor r

years.

Considering all PWR's, there have been 9 instances in 280 reactor _ years.

(Tr. 6093, 6107, Lantz)

These statistics are likely to understate the problem, since LER's are notoriously hard to interpret.

In addition, no statistice on emergency feedwater system success on demand are maintained so the Staff's statistics came caly from surveillance testing data.

CNermiel et al., f f. Tr. 6035 at 3-4)

-191-review of the subject in its Task Action Plan.

(Florida Power & Licht Co.

(St. Lucie Nuclear Power Plant Unit No.

2), CLI-80-41, 12 NRC 650, 652-3 (1980).

ALAB-603 was left in force with respect to its plant-specific creatment of St. Lucie.

At least as to the latter question, neither the Staff nor Licensee drew our attention to any ongoing program directed toward considering the reliability of emer-gency feedwater systems (or decay heat removal systems) or the extent to which lo s of emergency feedwater following a loss of main feedwater should -

.erically be considered a design basis event.

r 466.

The record in this case demonstrates that total loss of feedwater should be considered $ design basis event for TMI-l in light of the relatively high probability of loss of emergency feedwater and the high rate of demand for emergency feedwater to remove decay heat in the event of such anticipated operational occurrences as loss of main feedwater (and loss of of f site power).

467.

We make this ruling not by simply applying in some mechanistic way the Standard Review Plan guidelines, although i

we note that the probability of emergency feedwater failure j

I as calculated by the Staff is not even close to the SRP

-6 values of 10 and 10 per year for design basis events.

~

l This record as a whole provides insufficient basis for this 4

O m

a w -

-192-l l

Board to find reasonable assurance that the TMI-l emergency L

feedwater system is sufficiently reliable to remove decay l'

l heat when neaded.

468.

Based upon the foregoing, we conclude that:

1.

This record does not establish that the TMI-l amergency feedwater system provides a sufficiently reliable l

means of decay heat removal to permit operation of the facility.

p 2.

This record dcas not establish that the bleed-and-feed cooling mode is a sufficiently reliable means of l..

decay heat removal either as a substituto for or in addition to emergency feedwater.

In addition, reliance on bleed-and-feed for decay heat removal id fundamentally inconsistent" j,

with the principle that the primary reactor coolant system i

should be breached extremely rarely.

3.

This record does not establish that the means of I

l removing decay heat for TMI-l are sufficiently reliable to permit operativa of the plant.

1 469.

The foregoing findings apply both to the condition of the plant at restart and after the planned restart improve-2.ents are completed.

The only effort at a reliabili y analysis, 1

l that done by the Staff, showed surp-isingly little improvement l

attendant upon the longer-term modifications.

i l

i I

i

-193--

i 470.- On the basis of this record and in the absence of any i

other objective ~ criteria for judging the reliability of the

. TMI-i-decay heat removal systems, we conclude that the i

L following.must be shown in order to establish that TMI-1 is safe enough to operate:

1).that the combination of the probability of demand for decay heat removal and the probability of failure of emergency feedwater* is less than 10-6 per year; and 2) that the plant can be taken from hot standby to l-

' cold shutdown with only safety grade equipment, and 3) that the capacity of emergency feedwater has been increased so that in the event of an anticipated operational I(*-

occurrence, a single failure in thf emergency feedwater I

system ( e. g. loss of the turbine-driven pump) will not i

result in opening or the primary system relief or safety valves. **

l 471.

Based upon all of the foregoing, the Board concludes that the short and long-term actions recommended by the Director of NRR are not sufficient to provide reasonable it -

]

Feed an,d bleed cannot be relied upon because it transforms an anticipated operational occurrence into a LOCA.

There j

are no other decay heat removal systems at TMI which can jt be used at normal operating temperature and pressure.

i, l

An alternative to this may be the addition of a limiting conditic F

for operation requiring all three EFW pumps to be operable.

E Currently, plant operation is permissible with only two pumpn y

operable.

Thus, a single failure could leave only one motor-driven pump operable, resulting in opening of a relief or i

safety valve.

(Supra, para. 391)

194-assurance that TM -l can be operated without endangering the health and safety of the public.

o.

1 e

r

-195': '

~

lUCS CONTENTION 14-UCS Contention 14 was admitted as follows:

~The accident. demonstrated that there are systems and com-ponents presently classified as non-safety-related which can have an adverse effect on the integrity of the~ core because they can directly or indirectly affect temperature, pressure, flow and/or reactivity.

This issue is discussed at length in Section 3.2,

" System Design Requirements," of NUREG-0578, theiTMI-2 Lessons Learned Task Force Report (Short Term).

The following quote from page 18 of the report describes the problem:

"There is another perspective on this question provided i

by the TMI-2 accident.

At TMI-2, operational problems with the condensato purification system led to a loss of feedwater and initiated the sequence of events that eventually pesulted in damage to the core.

Several nonsafety systems were used at various times in the mitigation of the accident in ways not considered in the safety analysisi for example, long-term maintenance of core flow and cooling with the steam generators and the reactor coolant pumps.

The present classification. system does not adequately recognize either of these kinds of effects that nonsafety systems can have on the safety of the plant.

Thus, requirements for nonsafety systems may be needed to reduce the frequency of occurrence of events that initiate or adversely affect transients and accidents, and other requirements may be needed to improve the current capability for use of nonsafety systems during transient or accident situations.

In i.ts work in this area, the Task Force will include a more realistic assessment of the interaction between operators and systems."

The Staff proposes to study the problem further.

This is not a sufficient answer.

All systems and components which can either l

V

'l i

l 1

lNt' i: ?}' FL Ih "i.

ll @.

e

-196-h

.cause.or aggravate an-accident or can be called upon' to mitigate

^

an accident must be identified and classified:as components important to safety and required to meet. safety-grade design T

criteria.

I:

472.

Direct testimony on this contention was presented by UCS l'

(Pollard, ff. Tr. 8091), the Licensee (Keaten and Brazill, ff.

Tr. 7558) and the Staff-(Conran, ff. Tr. 8372, voir dire, Tr.

.8314-8371).

l 473.

In summary, UCS's testimony explained the significance in nuclear safety regulation of the distinction between safety-grade and non-safety-grade systems and components and. described n

't how the TMI-2 accident demonstrated three types of shortcomings in past practice:

1) certain systems previously classified as not safety-related are, in fact, important to safety; 2) some systems known to be important to safety do not meet all of-the criteria applicable to such systems and 3) the design basis for judging the capability of safaty systems has not been properly specified.

474.

UCS maintains that despite NRC's general requirement..that fa of: non-safety grade equipment should not initiate or aggravate an occident, there is currently no comprehensive and systematic ana.ykis done to demonstrate that this requirement has been-met.

In other words, the elaborate structure for ensuring diverse and redundant safety systems to mitigate accidents remains W

F

-197-

.-.s vulnerable to unforeseen failures of non-safety equi'pment, or' adverse systems. interactions,'just as during the TMI-2 In the af termath of. the accident, no systematic accident.

this problem.

effort has been made to identify and correct UCS proposes that all systems currently classified Therefore, as.non-safety-related which can in fact-either cause or aggravate an accident or be called upon to mitigate an accident should be identified and required to meet safety-grade criteria (Pollard, ff. Tr. 8091, so as to preclude adverse interactions.

14-1 to 14-9) at UCS's testimony described the manner in which the NRC's 475.

licensing process depends upon assessing whether the plant's structures systems and components can be relied upon to protect public health and safety in the event of occurrence of any of the selected design basis accidents or anticipated operational The Commission has developed a set of regulations occurrences.

fabrication, that define the minimum requirements for design, testing and performance which must be met if a construction, system or component is relied upon to protect the

. structure, These requirements are set forth in the General Design public.

industry standards I

Criteria of Appendix A to 10 CFP. Part 50, 279, which are incorporated in 10 CFR S50.55a, such as IEEE Std.

t' 50.

(pi. at 14-3) b and other sections of 10 CFR Part The introduction to the General Design Criteria provides 476.

i

~

as follows:

t i

agW o

ewt, et g e

e

^

64BEMP=

m 3

-198--

~

Pursuant to'the provisions of 550.34, an application for a construction permit must include'the principal design criteria for a proposed facility.

The principal design criteria ~ establish the necessary design, fabrication, construction, testing, and perfor-mance requirements for structures, systemt, and components important to' safety; that is, structures, systems, and components that provide reasonable assurance that the facility can be operated with-out undue risk to the health and safety of the public.

(App.

A, 10 CFR Part 50, introduction, emphasis added) 477.

As the language quoted above indicates, UCS testified that commission policy has been to apply the requirements of the GDC to systems variously referred to as' safety-related, safety-grade or important to safets.

It is assumed that only safety-grade systems are available to function during a design basis event.

Non-sarety-grade systems are, by contrast, assumed' to be unavailable and therefore, their functioning is not credited in evaluating the protection available to mitigate such events.

(Id. at 14-3 to 14-4) 478.

As additional support of this description of the : licensing' process, UCS cited the following language from the NRC's advance I

notice of proposed rulemaking.

" Consideration of Degraded or l'

Melted Cbres in Safety Hegulation" September 26, 1980:

l Furthermore, in reviewing reacter plant designs using the design basis accident approach, the NRC j

I-does not review all structures, systems, and com-t ponent.s but rather reviews, in varying levels of p.

9 e

'm l

~

A

199-detail, only those considered ' safety grade' by

.the applicant submitting a Safety Analysis Report.

Items, considered. by the applicant to be outside the scope of design basis accident analyses are generally-not considered to be ' safety grade' and are not re-viewed by the-NRC to see whether they.will perform as intended or meet various dependability criteria.

.This method of classification is based on the notion that things credited in the analysis of a design bas s event or specified in the regulations are important to safety and thus are ' safety grade' where all else is

'non-safety grade'.

Non-safety grade items do not

- receive continuing regulatory supervision or sur-jenlance to see that they are properly maintained or that their design is not damaged in some way that it might interact negatively with other systems., In-stead, these-items simply receive what attention may be dictated by routine industrial codes and by desires to enhance plant availabilit."

(Emphasis added) 479.

The language from the Commission quoted above confirms both that the terms 'important to safety" and " safety grade" are used interchangeably (..." things credited in the analysis of a design basis event or specified in the regulations are important to safety and thus are ' safety grade'...) and that all other equipment is classified as non-safety grade and receives cusory NRC review, if any.

i 1

480.

l-Further confirmation can be found from the Lessons Learned l

?

Task Force itself, which described the classification system and noted that the present classification scheme does not ade-quately recognize that non-safety systems can (and did at TMI-2)

.G

'W k N4 *

  • N N_.

M ene. _ w WDm 9-

n

-200-cause accidents and can (and did at TMI-2) be used in accident mitigation in ways not considered in the pla~nt's safety analysis.

(The full quote from P. A-18 of NUREG- 0578 is contained in the text of UCS contention 14) 481.

~ Uhile we may' appear to be belaboring this initial question concerning NRC's safety /non-safety classification scheme and 'its implications, the discussion is necessary because, surprisingly, NRC's witness discuted UCS's description of the licensing process.

This dispute will be treated in some detail later.

482.

The Board returns now to the substance of UCS's testimony.

~

i Examples were provided of the three types of shortcomings of the l.,

current safety /non-safety destinction which were demonstrated by the TMI-2 accident.

First, under the rubric of improper class-ification of systems, UCS noted that several systems that had been previously classified as non-safety (or not important to safety")

)

were used to mitigate the accident.

These include the reactor l-ll coolant pumps, which were used at vaicus times to accomplish core-lI cooling,the pressurizer level instruments, the PORV and its associ; block valve and the auxiliary (or emergency) feedwater system.

have been reclassified as important to safety.b/ (Id. at l4-4 Nona to 14-6) We note in addition that the failure of another non-safe-

)

_1/ Discussion of the specific role during the accident of the POR' lj and its block valve and the emergency feedwater system are contain.

]'

in the Board's findings on UCS contention 5 and Board question 6, b

respectively.

I

i i

i-

[,

ee m _ ene -,

_ Oe m

a ew

==-e m

M,

' " ---^

_C-h --

~'

- h 'r- *>

-201-i system the demineralizer - started the chain of events which led to the accident.

Much of the litigation of this contention centered around this aspect of the contention and.the general p

. question of whether adequate steps have been taken to identify i

-and eliminate adverse systems interaction and to recognize the role that so-called non-safety systems have in maintaining plant safety.

483.

~ The second category covered systems conceded to be important to safety which failed to meet all requisite criteria.

One example is that the protection system signals used to initiate ECCS were not derived from direct measurements of the desired variable - reactor vessel water level.

(pi..at 14-6) l

.484.

.The third. general area in which the accident highlighted t

pertinent shortcomings, ace'rding to UCS, was the inadequate o

determinationoftheseverityofthedesignbasiseventfor which safety grade systems must provide protection.

For example, the safety ar. slysis for TMI assumed no significant core damage or radioactivity in the prirsry system.

Hence, it was assumed that the low-pressure Decay Heat Removal (DHR) System could be used to remove decay heat.

However, during TMI-2, the DHR system could not be used because its leak rate and radiation shielding were inadequate to prevent excessive radiation i

exposure and because the primary system could rot be depressurized I

to the point at which DHR can function.

(Id. at 14-6 to 14-7) j 3 i

485.

UCS testified that the above demonstrated that the i

licensing review of TMI-1, while based on a fundamental dis-1

)

t i

..+

. _ _ _ ~........ -..

m~

m

-202-tinction between " safety" and "non-safety" equipment, was not - adequate-to identify all systems which are important to safety, to define the design basis for such equipment, or to identify and prevent adverse interactions between non-safety and. safety equipment which can compromise the ability of safet; systems to perform their necessary functions.

The Lessons Learned Task Force conceded as much:

The interactions between non-safety grade and safety grade equipment are numerous, var ied, and j

complex and have not been systematically evaluated.

[

Even though there is a general requirement that failure of non-safety grade equipment or structures

~

should not initiate or aggravate an accident, %here is no comprehensive and systematic demonstration that this has been accomplished."

(NUREG-0585, p.3-3)

( I_d_. at 14-7 to 14-8) i

(_. _.....

486.

UCS notes, finally, that the Staff has agreed in this

(({~

j litigation that systems currently classified as non-safety-

s.,

?

F related can affect the core because they can directly or in-directly affect temperature, pressure, flow, and/or reactivity.

(pd. at 14-8) l 487.

Having demonstrated that the lessons to be learned

[

from the TMI-2 accident include that the current safety /

nonsafety classification scheme does not adequately identify all systems important to safety or identify and correct all

}

potentially adverse systems interactions, UCS turns to the l

o.

-203-

/

. measures-which have been proposed by the Staff to respond At'the time that UCS's testimony was written, to'this issue.

-it appeared as if one long-term requirement _had been imposed addressed to this question, requiring the Licensee to " evaluate the interaction of non-safety and safety grade systems...

in exceeding to assure that any interaction will not result (NUREG-the acceptance criteria for any design basis event."

0585,.at A-14, Recommendation 9).

It was recommended that 1

(Id.)

During the this study be completed within one year.

course of'this proceeding it became apparent that even this i-recommendation of the. Lessons Learned Task Force will not b.

be implemented.

There are no plans to do any systems interaction review for EM1-I and TMI-4, is not included in. the.IREP program...(In f ra, para.'$@),

This is despite the fact that the ACRS 488.

,1 Llil letter on TMI-l of December 11, 1980 stated as follows:

g, E:

In accordance with our previous recommendaticas, 7

we believe that the Licensee should conduct reliability assessments of the plant as modified.

Such assessments should accelerate the acquisition of potentially sig-nificant safety information and would expedite the should development of the basis for further changes, They would also provide the Licensee they be necessary.

g with additional tachnical insight into the safety of

[

In addition, we believe the Licensee should the plant.

examine the plant from the standpoint of systems interactions that may degrade safety.

Although both.

_J-

-204-

'of these studies should beLeorducted on a timely basis, their completion should not be a condition for restart.

(Staff'Ex. 14, App. C) 489..While the ACRS did not consider-comoletion of such studies to be a necessary condition for restart, it can fairly be inferred from'its letter that at least committment to " timely completion" of such studies should be a restart-condition.

I 490.

In response to the ACRS, the Staff merely describes the so-called IREP program, intended as a " proving ground for procedural guide, lines" for Licensees and states that'it does not " feel" that TMI-l need be included in the program.

Beyond this bald statement of its feelings, the Staff states-I EL.

no reason why TMI-l can be safely operated nor makes any.

substantive response to the ACRS's concerns.

The record is quite clear.that the studies specifically called for by r

the ACRS will not be performed at all, much less on a " timely basis."

491.

The essence of UCS's contention is a simply-stated question.

Given that the accident demonstrated that systems presently classified as non-safety and receiving i

little or_no NRC review can cause accidents and/or be called I

upon to mitigate them, and given that there are no present 6

I

=

=

... *===

7.

e

m i

-205-plans to identify and upgrade-these systems and/or to preclude interactions.between safety and non-safety systems, what is

  • he basis for finding reasonable assurance that the plant is safe enough to operate?

D 492.

Before proceeding to discuss the positions taken by

.the Staff and Licensee, the Board notes that there was vir-

)

tually no substantive cross-examination done of UCS's. witness

,i-by either the Licensee or the Staff.

Other than posing its usual series of questions about whether the safety concerns expressed by UCS were unique to TMI-l or covered other plants as well, the Licensee pursued only one issue:

are there circumstances where the Staff can and should mandate a partial 1.--

upgrade of non-safety equipment wiEhout going all the way to j

i tull safety grade?

While noting that past NRC practice in

.A implementing the GDC prior to this case has not encompassed E.

partial upgrade, Mr. Pollard stated that such partial upgrading might be justified from an engineering standpoint if -it were based upon the results of technical analyses assessing the degree of improvement to safety gained by the partial upgrade, comparing that with the degree of improvement to be gained by full upgrade and establishing that the partial upgrade causes i

no adverse effects on plant safety.

(Tr. 8123, Pollard.)-No such analyses have been done in this case.

(Tr. 8613-8621, Conran) 0 4

e

^mN-

-._,_ r N-

7..

-206-NRC Staff Testimony 493.

The Staff testimony on this subject was presented by James Conran, ff. Tr. 8372.

UCS did an extensive voir dire of Mr. Conran, culminating in an objection to his testimony on'the grounds that the witness was not qualified to present it, that his experience with the agency was very largely in unrelated areas, that his experience with the systems inter-action issue was tangenti'al at best and th't he had no direct a

experience with TMI-1, nor knowledge of the TMI-2 plant systems.

r (Tr. 8365-8369)

This objection was overruled-by the Beard and the evidence was admitted.

However,, the matters raised on

~

g;. '

voir dire and in cross-examination ~do substantially affect the weight that can be attached to Mr. Conran's testimony.

We g

treat those now.

494. At the time his testimony was prepared, Mr. Conran had

. worked for the AEC/NRC for seven years, during which time he held 7 different jobs.

His positions with the ACRS and the Commission from 1973 through August, 1978 were in the area of i

safeguards of special nuclear material.

(Tr. 8323-8334; Conran)

While his job from July, 1977 to August 1978 was in the Office I

of Standards Desalopment, which was developing quali'y assur-ance standards for nuclear material processing facilities, "by far the greater percentage" of Mr. Conran's time was spent e

r m

y e -

.e

.Qm e

h a

m.M

._]_,

J J

-207-

!i t

).

continuing his safeguards work.

(Tr. 8333-8334, Conran),*

i 495.

From August, 1978 to May, 1979, Mr. Conran served as

.I a project manager in the Standardization. Branch - the first apparent contact he had with the licensing of reactors.

However, Mr.-Conran performed no reviews of any plant systems himself during this 10 months; he " coordinated" the review of others of the " balance of plant" design'and " assembled them into" t

the Staff safety review.

(Tr. 8342-7, Conran)

It is apparent that his duties were managerial rather than technical.

496.

Moreover, the review of the two standardized design applications under his jurisdiction was suspended before either of the Staff safety evaluations were-even published.

(Tr. 8347-8, C 24 ~ -

497.

Mr..Conran was then assigned 5for one year to the.TMI-2 Lessons Learned Task Force.

He monitored the activities of L

gg the ACRS so that they could be coordinated with Staff work E.

E without duplication.

(Tr. 8348-9, Conran)

He was not assigned to any of the subgroups with responsibility for particular substantive safety issues and wrote no part of the Lessons

~

Learned Report.

(Tr. 8353, 8349-50, Conran)

He wrote no The field of " safeguards" is related to protecting special nuclear material from fuel cycle facilities which may be h

capable of being fabricated into nuclear weapons, from diversion into the hands of unauthorized persons.

(See, e.g. 10 CFR Parts 70 and 73)

There is little if any apparent overlap between safeguards work and the work involved in reviewing commercial nuclear plant safety systems for the i

purpose of licensing pursuant tol0CFR Part 50.

e S.

m

-208-

. t --

h r

9 internal memoranda or draft portions of the report of the Lessons' Learned. Task Force.

(Tr. 8357)

Indeed, Mr. Conran conceded that his_ qualifications with respect to the systems interaction issue are no greater than his qualification for any of the safety issues raised by the TMI accident.

(Tr. 8356) 498.

Af ter the publication of NUREG-0578, it appears that Mr. Cc was not involved in work related to'TMI-1 until he was assigned' to present the testimony on thir, contention.

(Tr. 8618, 8320,8364 Conran)

That assignment was made in mid-September, 1980.

His testimony -was filed approximately two weeks later.

(Tr. 8320,*

Conran)

Obviously, such a schedule does not permit much time to review the status of the case and the relevant documents,

' La to deliberate upon the issues andito draft the testimony.

499.

It would apaear from his statement of professional qualifications tha t Mr. Conran might have acquired expertise in the area of syttems interaction when he was assigned to the new Division of Systems Interaction in approximately March or April of 1980.-

(Tr. 8325, Conran)

However, in the "early months" he was assigned to the budget rather than substantive work.

(Tr. 8379, Conran)

Considering that'his assignment began in Apri1, that the early months were devoted to developing the I

budget, and that he was assigned to present this testimony in mid-September and produced it in little over two weeks, precious gg ee qui,w e

'goe emammur +

  • MM****

N"M

  • -M

-"* ' D* '88--

  • t D

4:

h;.

x 1-209-' -

.little time could possibly have been devoted to considering the substance-of the systems-interaction issue generally, not.

to. mention ~the specifics of TMI-1.

500.-

While Mr. Conran has held a number of positions at

.AEC/NRC and we do not question his intelligence, there is

'little evidence that he has acquired direct experience in the areas pertinent to our inquiry here.

As discussed above, he has apparently never had personal responsibility for the review of 'any safeth system for any operating nuclear power generating facility.

(Tr. 8431, Conran)

(Nor, or course, has he designed such systems).

Moreover, he can hardly be classified as an expert in the systems interaction issue.

The great bulk of his direct regulatory experience is in the safeguards field.

14 His testimony indicated heavy relianch on conclusions of other people or work which he assumed had been done by other people.

kik (Tr. 8489-92, 8545, 8547-9, 8554, 8555-9, 8607, 8614-15, 8616-18, 8620, Conran) 501.

Moreover, there is another aspect of his testimony which troubles the Board greatly and reflects poorly on the evidentiary weight which can be attached to it.

That is, the testimony purports to present a discussion of past and current staff practice concerning the classification of plant I

systems and the definition of "important to safety" and " safety grade" but the evidence indicates that these were developed solely for the purpose of this lit igation and only then cir-culated through the rest of the staff which was directed to

~

m.

-ma

. a meenr a-

1

-210-conform its' testimony to Mr. Conran's construction.

(Tr.-8318, Conran) 502.

Other staff witnesses whose testimony was filed earlier than Mr. Conran's, Mr. Jensen for example, used the terms "important to safety" and " safety grade" in a manner which conforms to UCS's use of the terms rather than Mr. Conran's.

Mr. Conran refers to these as " careless."

(Tr. 8 319, 8523-8524, Conran)

Moreover, the Commission and the Lessons Learned

(

Task Force also use the terms interchangeably, (supra, paras 479 - 480 ).

503.

The Board believes that the rer:ord indicates, at: least with respect to che portion of Mr. Gonran's testimony which L'

attempts to draw a distinction betwhen the terms "important to safety" and " safety grade" with important regulatory implications Lsg

.that the testimony is largely a post-hoc attempt for purposes of this litigation to construct a facially logical explanation of staff practice which will support the Staff's conclusions in opposition to the contention.

Such post-hoc constructs have little weight.

504.

We now proceed to the substance of the Staff testimony, Conran ff. Tr. 8372.

He began by asserting that there is an important regulatory distinction brtween the plant systems I

covered by the phrase " structures, systems and components The substance of the testimony will be discussed in detail below.-

t

-211-9 1mportant to safety" and those which are " safety grade."

.That is, he claimed that the two phrases are'not essentially interchangeable According to.Mr. Conran, only systems and equipment which perform " critical safety functions" (alterm

~

nowhere used in the regulations, Tr. 553C-1, Conran) need be safety grade, while other equipment "important to safety" need not be.

Regulatory Guide 1.29, which deals with protection from earthquakes, is said to contain a list of all " safety grade"

}

equipment.

Thus, Mr. Conran challenges UCS's assertion that when a system is determined to be "important to safety", it has been required to meet the applicable GDC which ford the definition of " safety grade."

(Conran, ff. Tr. 8372 at 4-6) o.

Conran goes on to testidy that there is no need to

  • ~ -

505.

Mr.

fully upgrade any non-safety grade equipment which either L,a contributed to or was used in mitication of the TMI-2 accident.

EL -

~

E He states that three criteria are used by the Staff in deciding w

r whether such upgrading is required:

1.

Will the failure of the non-safety component in and of itself degrade the capability of safety systems so that they cannot mitigate accidents?

2. ' Will the ef f ects of f ailure of the non-safety system I

alone exceed the capability of properly-operated safety systems?

3.

Is the non-safety system actually required to mitigate an accident assuming safety systems are properly operated? (ld., at 8 - 10)

O

r A

l~

212-506.

According,to Mr. Conran, if "by careful analysis or actual experience," the answer'to any of these questions is

-yes, upgrading may be called for.

(jgi. at 10)

However, he states that none of the TMI-l non safety systems were used until after' improper operation of safety systems had caused i -

core damage.

(jyd. at 8) Nor did failure of non-safety systems 1

1

-cause the ccre damage.

(Id..at 11) Hence, his criteria for

?-

upgrade are not' met.

507.

Mr. Conran then states that even though upgrade is l

not called for by application of his criteria, the_ Staff may decide to require partial upgrading "as a prudent measgre",

l (jgd. at 10) as it did with the PORV pressurizer heaters and s

d

-emergency feedwater.

( I d.. at 13-15)

No criteria for the exercise of this prudence are offered.

. Ld 508.

The Board will deal with these three topics seriatim.

E.I y

Important to Safety / Safety Grade Distinction 509.

Mr. Conran was cross-examined extensively with regard to his assertion that the phrase " structures, systems and components important to safety" in the introduction to Appendix A to 10 CFR Part 50 is an extremely broad category and only 7:

equipment.with " critical safety functions" need be safety grade and meet the applicable General Design Criteria.. Mr.

,h

.I e

--y,...a-

.,n,

-t>s

--r"

fl

-213-t Conran was asked to. identify equipment which is in his view not "important to-safety."

He identified the office building, rest room'and water cooler.

(Tr. 8404-6, Conran)

He admitted that the term " critical safety function" is used nowhere in the regulations, but is rather his own. term.

(Tr. 8530, Conran)

We note that Mr. Conran's definition of the terms." import-510.

ant to safety" and "sarety grade" can be found nowhere in any AEC or NRC documents, regulations or regulatory guides.

UCS's witness, who served as a member of the AEC and NRC licensing staffs and as a licensing project manager for 6 1/2 total has never seen these definitions nor heard them L

years,-

used in any NRC proceeding nor heardbthem in discussion with any NRC staff member.

(Tr. 8099, Pollard)

As discussed above, jf after Mr. Conran developed his testimony, it was circulated h-to staff members who were directed to conform their testimony r

to these definitions.

(Tr. 8319, Conran)

The above combine to lead us to conclude that Mr. Conran's definitions were developed solely for the purpose of this case and have not appeared before in NRC practice.

Conran states that Regulatory Guide 1.29 contains 511.

Mr.

i a list of all safety grade equipment. He derives this from reasoning that, since Reg. Guide 1.29 lists equipment that is e

m

- -- e e

e.

4

-214-x required to perform what he believes are " critical safety functions"'after an earthquake, this list.of equipment contains, ergo, all equipment that need be safety grade. - (Conran, ff.

Tr.-8372 at 4-5).

While this has a veneer of logic, it does not stand up to scrutiny.

512.

First it must be pointed out that Reg. Guide 1.29 never states'that the listing of systems and equipment contained therein constitutes a list of all safety grade equipment.

i lTr. 8537-8, Conran)

Nor does any other NRC document so state..Indeed, the parties were asked earlier in the pro-

~

ceeding if such a listing existed and stated that it did not.*

513.

Moreover, GDC 2, which is the genesis of Reg. Guide 1.29 o.

explicitly requires that " structures systems and components imoortant to safetv be designed to withstand the effects of natural phenomena such as earthquakes..."

(Tr. 8096, Pollard;

~

Tr. 8531-2, Conran)

Thus, one must conclude that the listing of equipme'It in Reg. Guide 1.29, which bounds the coverage.

of GDC 2, is a listing of equipment "important to safety."

This reinforces the proposition that "important to safety" and " safety grade" are indeed interchangeable.

514.

We were also disturbed by a circular and self-se.ving

[N.B.

We have not yet been able to locate the transcript reference to this, and are still attempting

+,o search for it. ]

t I

k

" G(mbn..

r n

I

-l :

-215-9 element in Mr. Conran's testimony.

According to the witness, a system or component could be "important to safety" within the; meaning of the introduction to the GDC yet not be required to meet any of the specific GDC or Regulatory Guides, including even the quality assurance provisions of Appendix B to 10 CFR Part 50.

The explanation offered is that, although the system or component is important to safety within the meaning'of GDC 1, its level of importance is not enough to cause any specific requirements to apply.

(Tr. 8409-8426, particularly 8419, I

Conran)

Such an interpretation renders the phrase "important tosafety"virtuallymeaninglessasaregulatoryconcepksince no regulatory consequences whatever ' flow from it.

This provides i

  • " " ~

an additional reason for the Board to discount the testimony.

515.

Finally, the witness stated that his understanding and L

.B1 definitions had been applied during the licensing of TFI-1.

(Tr. 8411, Conran)

Yet there is equipment listed or covered r

by listings in Reg. Guide 1.29 which is not safety grade for It1I-1, including the PORV and emergency feedwater system.

(;Tr. 8537-42, Conran)

Mr. Conran testified that he doesn't know enough about the " details of the system" to know whether non-safety components are listed in Reg. Guide 1.29.

(Tr.

I 8633, Conran; see also Tr. 8692-6, Conran)

Since this goes to the. heart of his testimony, we cannot treat it lightly.

4 S

e y

-216-l If Reg. Guide 1.29 is not even a listing of all safety-grade equipment (and none other), the " logical" construct built by Mr. Conran falls completely.

516.

Finally, we discerned from the witness's demeanor and use of language the sense that he was sometimes improvising.*

We conclude based upon all of the foregoing that Mr. Conran's argument that equipment "important to safety" has not been (and need not be) treated as safety-grade must be rejected.

517.

Before leaving this section, we wish to emphasize that because a system or component is important to safety, that does not mean that all the GDC apply, nor does UCS so srgue.

C,ertain of the criteria apply only ;o certain types of svstems e.g. the ECCS need not meet the criheria for containment 4~-

l l

heat removal.

(Tr. 8096-7, Pollard)

Moreover, the design

!L T1 basis for certain systems will determine whether particular lE.

]{

GDC apply.

For example, systems needed only after an earth-quake need not meet fire protection requirements.

(Ld.)

i However, once a system is determined to be important to safety, and its design basis established, it must meet the applicable GDC.

That is what makes a system safety grade.

(Tr. 8096-l }

See e.g.,

Tr. 8413-14 ( he has not considered what. equipment

I is not "important to safety");

8411-12 (his " impression" is that his definitions were used during TMI-1 licensing);

Tr. 8419 (he hasn't been able to construct a logical definition of safety-related) ; Tr. 8419 (it " occurs" to him that "it may be" that something important to safety within the meaning of GDC 1 might not be sufficiently important to call for the application of any specific regulatory requirements); Tr. 8489-l 92 (he consulted a colleague by telephone overnight since he was "taken aback" by some of the wording of the regulations)

I l

f, )

-217-8101, pollard)

Criteria for Uoerading 518.

We now proceed to the criteria for upgrading proposed by the Staff witness.

(Suora, para.,505)

Essentially, these criteria would require as a requisite to upgrading a showing that failure of a non-safety system by itself would cause core damage or that use of a non-safety system was required to mitigate an accident assuming properly-operated safety systems.

Since the witness believes that non-safety equipment was used only after improper operation of safety systems resulted in core damage, he d,oes not believe upgrading of these (or other) non-safety systeis is required.

(Conran, ff. Tr. 8372 at 11) 519.

However, on cross-examination it became clear that th'e witness could nor support this statement.

He does not know, for example, whether pressurizer heaters or the reactor coolant pumps were used before core damage occurred.

(Tr. 8603, Conran)

In fact, the reactor coolant pumps were used for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> and 40 minutes at the very outset of the accident before core damage occurred.

(Suora para. 15)

It was apparent that the witness had no basis for claiming that non-safety systems were used only af ter improper operation of safety systems resulted in core damage.

(Tr. 8603-8604)

^

-218-520.

-Moreover, to the exten,t that the testimony implies that

" careful analysis" was done by L a Staff to determine whether

'any non-safety grade equipment should be upgraded, it is inaccurate.

Mr. Conran himself never did such an analysis.

-(Tr. 8547, Conran)

He thought that "someone like.Mr. Jensen might be involved in that sort of thing."

(Id.) When specific-ally asked' what analysis was done by anyone on the Staff c f the TMI systems to enable the Staff to determine whether any TMI-1 non-safety systems' meet his criteria for upgrading, the only thing he could point to was the B&W computer

.ialyses of transients and accidents discussed in Mr. Jensen's testimony Th're is on UCS Contentions 1 and 2.

(Tr. 8551-8554, Conran) e LT -

- nothing in the description of that hork that suggests that Lit is directed toward identifying adverse systems interactions

[i.

or addresses itself to the criteria for upgrading put forth EL' g

-by Mr. Conran.

(Tr. 8555-8566, Conran, see also Tr. 8103-8107,' Pollard) 521.

Based on the foregoing, even if Mr. Conran's criteria for upgrading systems to safety grade are the correct criteria, there is no evidence that they have been epplied properly to TMI-1.

l 522.

Finally, with respect to the issue of whether non-safety grade equipment should be partially upgraded as an exercise of " prudence", the witness was questioned on what-1 e

= N nemW ONm n-m ua NC-'

_W,,M*

,M,

_***#6

,6-*

6,

9****

NN

e

-219-n t

ij bases the Staff used to determine what aspects of the system or equipment should be modified'- in other words,'what GDC shoule 4

1 be applied and which ignored in the partial upgrade?

He stated that a " judgment had to be struck as to whether the additional reliability that might be gained by that was necessary."

~

(Tr. 8613, Conran) 523.

However, there is no indication that anyone on the f

l Staff ever did the review necessary to exercise that judgment"

' -or even determined what would be needed to make the particular equipment fully safety grade, what would be gained in reliability and what the cost would be.

(Tr. 8614, 8619-20, Confan)

Mr.

Conran knew of no such analysis.,He testified that this is L.-

because of the " circumstances undhr which these kinds of judg-ments were made," that they were " hot coal Atems". - (.Tr. 8614, g

Conran)

Apparently the decisions had to be maca very quickly E'

on what to include in NUREG-0578, allowing little time for analys.

a E

F

( I_d. )

d 524.

However, even after NUREG-0578 was completed, when there clearly was time for more thought, no such analyses have been i

done.

(Tr. 8614, 8619-20, Conran)

It is apparent that the Staff does not know "whether the additional reliability that might be gained" by making the PORV or other equipment safety grade is "necessary," or desirable.

Although it claims to have exercised judgment, the Staff is not in possession of 4

m.

_mm

-220-the basic facts necessary in order to exercise judgment.*

Hot coal or not, the perceived need to make decisions quickly does not justify the inability to support those decisions.

525.

We close by dealing with the implication in the testimony

-that the systems interaction problem will be dealt with in the longer-term for TM7-1, suggesting that there is no need 6

for the Board to mandate action now.

(Conran, ff. Tr. 8372 at 1 15).

Mr. Conran lists a series of long-term actions.'

In fact, the only one specifically addressed to systems inter-L L

action is Recommendation 9 of NUREG-0585.

(Tr. ' 8 67 8, Conran)

That recommendation was not implemented.

There is norexisting requirement for any systems interaption study for TMI-l'.

(Tr.

%~

8685-8689, Conran)

TMI-1 is not dhrt of the IREP program (Tr. 8709-10, Conran).

While t-ir. Conran personally disagrees LM Nor did the witness know in what ways either the pressurizer heaters or PORV are non-safety grade.

He never looked at r

the current design because the Staff had already decided that these com?onents did not need to be safety grade.

(Tr. 8684-8687, Conran)

The reasoning reflected in these answers seems curiously backward to us.

How could the Staff decide what measures were needed to improve the l

reliability of ti.cse components without first endeavoring to determine the ways in which they are vulnerable to failure?

i I

L 1

1 L

gm.,

w

,e-e

..e amon g, y

em gmge.

g-ge g ee aime m,,e n

n,,

-221-t with this omission and still strongly favors a specific systems interaction study (Tr. 8639-8690, 8703, Conran), this curiously does not seem to affect his judgment about the propriety of allowing T..I-1 to operate without even a committment to do such i

a study.

526.

The Board has described this Staff testimony and the l-pertinent cross-examination in an unusual degree of detail in order

}

to clearly indicate why we have concluded that it is not reliable.

t l

In short, the testimony did not withstand close scrutiny.

i Licensee's Testimony 527.

The Licensee offered only two pages of testimony on this contention.

(Keaten et al, ff. tr. 7558 at 14-16)

Its position e

is a simple one.

The Licensee asserts that the TMI-2 accident did not demonstrate a weakness in t.- " inherent design capabilities of safety systems to respond to accidents, including those caused g

by failure of non-safety systems.

If HPI had not been throttled, bl EL everything would have been fine; hence, there is no need to consider i

y the issues raised by UCS.

528.

This position simply ignores the implications of the TMI-2 accident as they are elucidated by the Lessons Learned Task Force and referenced by UCS.

Perhaps the 'learest statement of the c

pertinent lessons learned is cor ained in Section 3.2 of NUREG-0572 (referenced in the text of the UCS contention).

First, there is the paragraph quoted in the UCS contention.

This paragraph, none of which s :s disputed by the Licensee, established that the failures of non-safety equipment contributing to the accident and the use of non-safety systems in ways not considered previously in safety analyses, raises issues not adequately recognized by the n.,_

y.

-222-HRC's'present clhssification schemc.

Ih part'iculari the accident

' indicates:

1) requirements may be needed to reduce the frequency of events that initiate transients and accidents and 2) requirement may be needed to improve the capability of currently classified non-safety systems to qperate during transients and accidents 529.

The Licensee made no response whatever to either of these issues. The accident has caused no change in the Licensee's thinkin with regard to potential systems interactions.

(Tr. 7703-4, Keaten In fact, Mr. Keaten stated that it is " absolutely acceptable" for the failure of non-safety systems to cause challenges to safety

.f systems without even knowing the acceptable frequency of such chall.

(Tr. 7532-3 Keaten)

.Th'is is fundamentally inconsistent with a major theme of the lessons learned.

(See Supra paras. 45-46, 55-!

59, 63, fn. at p 37, 151, 159, 160 (quoting 32.11 of NUREG-0578),

176-181)

[

530.

The Licensee's position is,in essence, tham ce core dam 5it'g at TMI-2 bcEUrded becaus'e iof:' improper 2.operatorc. action,.and.. improved b

ator triin'ing will'yr'ecluden ': de'p'e'tition,S no'ifurther ' attention need a

r

~

given?.todth(-bth'er'sdfety*?i's'siisp Wh1clicthe 'a'n'Ty' e'so$l 'h'e acrident a

s t v t'ifi'er 'and. arti' i21at'ed.'. 2If this wer?ea acceptablew most of. th'e lesson c

~

Fearnedr requirements would be purel'yitratuitous.

We reje'ct"the- :.-

iiivithtion ' to' put lon blinders.

531.

A prime illustration of the narrowness with which the l

Licensee approached the safety implications of the TMI-2 accident is the curious way in which Mr. Keaten '" rebutted" UCS '.s. test'imony that an important lesson learned was the importance of the emergency s

3 r1

,_ e.m M^

-m

-223-0 g

feedwater. system.

(Tr. 7569-70).

Mr. Keaten professed to be able to understand how such a conclusion could be drawn from ti accident.

(Id.)

532.

This testimony is mystifying in light of the finding of the lessons Learned Task Force that "the need for an emerger.

feedwater system of high reliability is a clear lesson learned from the TMI-2 accident" (Tr. 7764-5, Heaton) and our findings

" card Question 6.

It indicates the Licensee's inability or unw 0

1.. ness to consider etjecti'vely the meaning 'of the TMI-2 accide 533.

Even within the four corners of Licensee's testimony, statements are made which cannot be supported.

(

534.

For example, it is stated that while equigment needed "to provide the greatest assurance of protection for the most severe plant accidents" is desi ned and constructed:"to.the'-hig standards", other plant systems are still " designed to less k

stringent but still rigorous standards.'

However, each time he was questioned about a particular piece of non-safety grade equ.

E

.the witness,.could not id'eh.tify, any' NRC; r'equirements' which. appli r

'these, professing an unfamiliarity with what went on in the lici process for TMI-l or TMI-2.

(Tr. 7688-9, 7693-4, Keaten)

Thus his statement is little more than a soothing platitude.

The Bot can make no assumptions about the quality or reliability system classified as non-safety grade.

535.

Another aspect of this issue is the use of non-safety c instrumentations to determine whether and how the operator shou:

perform safety functions.

The Licensee conceded that non-safeta 6

W m

g p.-

z i

-224-

~

~

-equipment - the pressurizer level instruments -

were the only instrumentation available to determine primary coolant inventory.

When they were lost, the. operators had to resort to filling the system full, letting it drain down through the leakages in the system and do a calculation of pressurizer level as a function of time and an uncertainty analysis of that' calculation. Utr.

7578-9 Keaten) 536.

The witness agreed that is is important to know primary mystem inventory, but the pressurizer level instruments will not be made safety grade.

(Tr. 7579, Keaten) u 537.

The witness also agreed that the non-safety grade incore ll thermocouples were used to indicate the condition of the core.

(Tr. '585-6, Keaten)

There are suggestions that their readings we not believed at least partially because they were not safety grade (Tr. 7583-7592, Iteaten)

A.

538.

M re ver, both the incore thermocouples and the pressurizc ll level instruments are relied upon today in the plant emergency pro-h cedures to indicate to the operator when HPI ca. be thrott. led.

r (Tr. 7592, 7654)

In the case of the incore thermocouples,.the..witr could identify no ot..ar instrumentation which the operator can use during a LOCA to determire.the. tempera ture lin the downcomer..

(Tr. 7623, Keaten) 539.

The pressurizer level instruments are used to tell the operator when HPI should be throttled to avoid exceeding the e

temperature-pressure limits on the reactor vessel, (Tr. 7654, Keate a function which the witness agreed is important to safety.

(Tr.

7596, Keaten).

)~

4 e

y

~

w-

~w w

-225-540.

It is thus apparent that the TMI-l operators are

{

directed to perform iraportant safety functions depending upon non-safety grade instrumentation.

Beard CJnclusions 541.

Based upon the foregoing, the Eoard concludes that the l

i analyses of the TMI-2 accident clearly showed that systems presenti classified as non-safety, and hence receiving little or no NRC review can cause accidents and be used to mitigate accidents in ways not originally considered in the plants safety analysis.

The present NRC classification system does not adequately recognize either of these kinds of effects that non safety syster.s can have on the safety of the plant.

542.

The Board concludes further that while the Staff has recognized the need to consider upgrading non-safety systems to L

reduce challenges to safety systems and to improve the capability M

Et of non-safety systems to operate during accidents and transients, E

y the Staff has

.o program or plan whatever to take the first required step in this process - the undertaking of a comprehensive study to identify potential systems interactions at TMI-1.

543.

Even as to the non-safety equipment specifically involved in the TMI-2 accident (e.g. PORV, pressurizer level instruments) the Staff made only a hasty and ill-documented effort to determine i

whether and to what extent they need be upgraded.

Insufficient basi was presented to justify the Staff's decisions.

9 e

a

-226-9 544.

It is simply' unacceptable to acknowledge that an unresolv safety' problems-exists and then to ae as if this plant can be operated without restriction having taken no steps nor even commit to any future steps directed toward resolving that problem.

545.

We find a direct analogy between this situation and than presented in Virginia Eleccric and Power Co.

(North Anna Nuclear Power Station, Units 1 and 2), ALAB-491, 8 NRC 245 (1978).

There, the unresolved safety issues ircquestion were those identified by the ACRS and the Staff in its Tack Action Plans.

The Appeal Board stated:

Of course, these ' unresolved' issues cannot be disregarded in individual licensing proceed-ings simply becaus they also have generic applicability; rather, for an applicant to succeed, there must be some explanation why construction or operation can proceed even though an overall_ solution has not bee 1found.

L i

' In1 Where operatien of a facility is involved, similar analysis is necessary; but as to I

certain' issues, the justification for giving an applicant the gresilight can obviously be more difficult to come by.

For example, the reason often given for allowing construction i

activity is that there is still time to find a solution and build it into the plant's designs.

At the operating license state, that reason is not available.

But there may be one or more other justifications for permitting the plant _to operate.

The most comme ^ a -* that

a. solution satisfactory for the particular O

P m

---r w

---r~

e-

,9-pm,-m

+ < -,. -

. =.

-227-d facility'has been implemented, a-restriction on the level or nature of operation adequate to eliminate the problem has been imposed; or the safety issue does not arise until the later years of plant operation.

( 8 URC at 248) 546.

No such justification has been suggested to this Board sufficient to allow us to authorize unrestricted operation of TMI-l despite the existence of this safety problem.

Nor, as the Appeal Board indicated, does the problem go away because

,' i 1

it is generic.

The fact that other plants are subject to the

.f j.

same problems and uncertainties is no reason to ignore,the issue when it comes to us in a case within our jurisdiction.

547.

We are also influenced by thq fact that tb~e ACRS recommended

" timely completion" of systems interaction studies for TMI-1, L

a recommendation that the Staff chose to reject, without,

'na

EK in our opinion, apparent justification.

~2 548.

It is the Board's opinion that TMI-l should not be 1

permitted to operate until the completion of a comprehensive engineering analysis which identifies potential interactions between non-safety and safety systems and i

1) j non-safety systems which can cause or aggravate an

]I accident'are either upgraded or their potential adverse effects are effectively isolated from safety systems and l.

2) non-safety components and systems (inc:.uding instru-3 6

-228-mentation) which are called upon in the mitigation of accidents and transients are upgraded to safety grade.

549.

Based upon all of the foregoing, the Board concludes that the short and long term actions recommended by the Director of 11RR are not sufficient to provide reasonable assurance that TMI-1 can be operated without endangering the health and safety of the public, i

i i

e t.-

..E

'O F

6

'D L

m m

=

L i

-229-BOARD QUESTION NO. 2

l "I

550.

The Commission ordered that the subjects to be considered in this proceeding were to include a determination of: whether:

{

the short-term and long-term actions recommended by the-Director

. l.

of Nuclear Reactor Regulation are necessary and sufficient to provide reasonable assurance that TMI-l can be operated without endangering the health and safety of the public.

(Order and Notice of Hearing, August 9, 1979, at 12)

In this section of our findings, we discuss the latter issue - whether the modifications to TMI-l are suf ficient to justify restart.

551.

The Commission in its August 9, h979 Order provided the t

Board with the discretion to determine, subject to Commission I

. c-;

review, what matters must be resolved prior to restart.

In E":

-Ib this regard, the Commission. subsequently expressed its belief w

that TMI-l should be grouped with reactors which have received 6

operating licenses, rather than with reactors with pending y

-[

operating license applications.

However, the Commission empha-sized that it expected the Board to find to the contrary when the record so dictates.

(CLI-81-3, at 7) h 552.

Prior to the start of the evidentiary hearing, the Board informed the parties 65 its concerns as to the adequacy of the.

L s

e.

-230-proposed actions for TMI-l and the type of evidence that would be very important in support of a position that the proposed actions are necessary and sufficient.

(Memorandum on NRC Staff Accident Sequences Report, June 23, 1980)

'553 We noted that the TMI-2 accidr t has been identified as having a probability (Kemeny report, p.

32) so high as to be likely within 400 years.

We stated that we would inquire as to the basis for any claims that the proposed actions will reduce l

the probability by several orders o:" magnitude.

(Id., at 2) 554.. We also noted that in the past when the Staff has identi-fled a particular accident as being of concern, they have required

-6 that the probability be reduced to less than 10

/yr.

(Id.)

555.

Wirhout telling the Staff what we would require in et.e

~

nature of evidence, we stated that evidence to the effect that i

El all accident sequences (with a nexus to the TMI-2 accident) will EB

_6

{7 each have a probability of less than 10

/yr would be very c/-

important in support of a position that the proposed actions t

are necessary and sufficient.

(Id.)

r l

556.

We subsequently posed the following Board Question 2:

"The board stated its concern with having an adequate I

record on the sufficiency of the proposed short-term and long-I term actions to protect the health and safety of the public.

I t

8 y-e

'?.

$e

  • me
  • Yo*

b I

.,%,*es,

l

-231-

r-1

?

. Without further explanation the question may appear to j

invite conclusionary testimony of the ultimate factual issues I

to be decided by the board.

LCommission's August 9, 1979 Order, 10 NRC 141, 128).

This is not what the board has in mind as l

a response to the question.. Our concerns were expressed in part h

.cin the< June 23, 1980 memorandum on the staff 's. report on TMI-1 ~

accident sequences.

To explain further:

We assume that the staff and licensee may present evidence that each Category A 1

and each Category B recommendation in Table B-1 of NUREG-578 l.

l (Orders items ST 8 and LT 31, and that each preventative and mitigative measure identified with respect-to a given accident t

sequence in the staff's TMI-l Core Damage Accident Sequence Report will be, at least, sufficient to resolve the related safety problem or accident sequence.

However, nowhere have we seen in the Restart Report, SER, the Accident Sequence Report, or elsewhere, an explanation as to how.the staff or licensee l

has determined that all of the necessary TMI-2 related recommend-1 ations have been identified and that all the appropriate accident llEi:

I-sequences have been addressed.

The board wants testimony or g7 other evidence which explains, if such be the case, how the

[-

licensee and the staff have' concluded that the NUREG-0578 short-and long-term recommendations, other subsequent safety recommend-t

, cions, and the identified accident sequences (with their respec-qg tive preventative or mitigative measurest are in their totality

"}

sufficient to provide reasonable assurance that TMI-1 can be operated without endangering the health and safety of the public.

The question is not intended to enlarge the scope of the hearing.

The response may be limited to consideration of accidents b

l following a loss-of-feedwater transient."

(Tr. 23921 o

y'd s...

' i.

.oe ql

~

't

-232-557.

Testimony on this Board question was presented by the S taf f.

(Ross, ff. Tr. :.5, 5 5 5 )

The same testimony was adopted by Staff witness Capra, (Tr. 15,554, Capra)

The testimony was prepared in October 1980 (Tr. 15,549, Cutchin) and wac

- introduced into evidence on March 18, 19 81 -( f f. Tre.. 15,5 55), "

~

l-five days before the issuance of CLI-81-3 on March 23, 1981.

The significance of these dates is discussed later.

558.

Basically, the tnrust of the Staff 's direct testimony l

was that those Action Plan

  • items which are both applicable l
m. TMI-l and required to be implemented prior to restart, provide the most significant improvements in safety and arb sufficient to allow TMI-l to restart.

(Ross, ff. Tr. 15,555,

~

at 3, 12) l

's 559.

The Staff defines this subset of Action Plan items as I

EL.

the combination of the "short-term actions" required by the

,: b

' u

,ut Commission's August 9, 1979 Order and the items identified k

n-in NUREG-0694 as being necessary prior to issuance of a fuel load or full powee license.

(Id., at 12) t-560.

The Staff provided no basis for its conclusion that t

NRC Action Plan Developed as a Result of the TMI-2 Accident, H

NUREG-0660, May 1980,-Revised August 1980.

6

..Lt.

. < =..

l j

-233-this subset of Action Plan items is sufficient to allow.re-stant.

561.

We discuss below the Staff's claim that those Action Plan items which are applicable to TMI-1 and required to be imple-mented prior to. restart, provide the most significant improve-ments in safety and are sufficient to. allow restant.

First we examinethose Action Plan items which the Staf f claims are not applicable to TMI-1.

Then we discuss the evidence concerning the Staff basis for deciding which Action Plan items (of those k

which,the Staff identified as applicable to TMI-1) should be re-quired to be implemented prior to restant.

562.

The staff testified that of the 279 items in th'e Action Plan, "186 Action Plan items do not apply to,TMI-L at this time."

(Ross, 1

ff. tr. 15,555,.at 7, emphasis added) 563.

The largest group of these items, 126 items, are claimed by 3y g ;,

the staff to be not applicable to TMI-l at this time because the b,_

items either do not apply to licensees / applicants or the items may gu.

- 5 ultimately lead to new requirements, but in a manner not yet deter-I mined. (Id.)

v(

564.

The Staff also claimed that 7 other Action Plan items are I

plant specific and do not apply to TMI-1. (Id.)

565.

The Staff identified the specific Action Plan items which it L

considered to be not applicable to TMI-1.

(Id., at table 1) 1

e

$Z;'

-234-We examined the nature of sore, ?f these "NA" and " plant specific" items to evaluate the validiry of the Staff's' testimony that the most significant improvements in safety will be achieved without implementing these items at TMI-1 prior to restant.

566.

The. Staff identifies Action Plan items II.C.1, II.C.2, and II.C.3 au " plant specific" and item II.C.4 as "NA."

(Id.)

567.

The II.C series of four Action. Plan itema generally are directed toward reliability engineering and risk assessment.

The objective is to identify high risk accident sequences at in-dividual_ plants and determine regulatory initiatives to reduce these high-risk sequences. Reliability requirements and the single fail'tre criterien will be improved.

Requirements for station blackout and "nonsafety" systems important to risk will be developed.

Consideration will be given to improving the " systems-interaction" issue in regulatory requirements. (UUREG-0660, at h

II.C-1) lhh 568.

Item II.C.l. is an interim reliability assessment program aC Eu (IREP) which consists of a pilot study of a single plant (Crystal River Unit 3, which has a B&W reactor) folicwed,by a study of p

t six plants.

These studies are expected to provide information i

necessary to develop: generic requirements to reduce high-risk accident frequency or consequences; improvements to the single failure criterian; requirements for "nonsafety-grade" equipment h

important to risk reduction; requirements needed to assure high reliability of engineered safety features and support systems;

--. s :%.-

.. n. a < w...., n _ w

.~,

p., _ _ _ _ _ _

-235-improvements to the resolution of generic safety issues (black-out, d-c power, systems interactions, ATWS, etc.);-improvements in _the limitina conditions for operation; improvements in operator training and in plant operating, maintenance, and emergency pro-cedures; requirements to address the B&W reactor sensitivity issue; requirements to address incidents of excessive feedwater flows t

and improvements in the focus of ' safety research programs. ( NUREG--

I 0660,_at II.C-3) 569.

Item II.C.2 is a continuation of item II.C.1 which plans a

IREP studies on all remaining operating _ plants. (Id., at II.C.-5) i

.'570.

Item 'II.C.3 is-a systems interaction study for purpose of O

coordinating and expanding work on unresolved safety issue A-17.

(Id., at II.C-6) involvesusingreliafilityenginneringtechiques 571.

Item II.~C.4 to' complement quality assurance and. provide a disciplined approach t

to systems engingeering and the development of procedures for EF_

startue, operating, maintenance and emergency procedures. (Id.,at II.C-E_:.

I' 572.

The record in this proceeding shows that th.se four Action p

Plan items have an important relationship to safety and that the A

Staff's basis for not requiring their resolutior. prior to restant I

is not based upon an assessment of the risk to public health and safety.

573. The Board (Dr. Jordan) questioned the Staff about its view

.up of_the importance of the IREP program with respect to identifying.

system interactions that could be critical and possibly overlooked w

s.~

3

-236-in the absence of a study of TMI-1.

(Tr. 15,615) 574.

The Staff testified that no system interactions studies are being scheduled very soon for TMI-1.

The Staff is trying to develop a policy on what is a good method for studying systems interaction and the extent to=which all licenses should be

~

-required to condu'ct ihch studies.

(Tr. 15,616, Ross) 575.

Experience with a systems interaction study at Diablo Canyon-identified in excess of 600 systems interactions. (Tr. 15,617, Ross) 576.

At Crystal River ' Unit 3, false signals to the integrated

~'

control system resulted in the control rods being withdrawn, the pressurizer spray valve opening, the PORV opening, and feedwater being cut back - all because the incoming information to the integnated control system was rendered' false by a power failure.

~

(Tr. 15,800, Ross) f I

-577. The IREP study at Crystal River Unit 3 failed to identify those jhk accident mechanisms which could precipitate the initiating event-h

'and at the same time degrade the reliability of the safety system w

called upon to respond to that event. (Tr. 16,911 Rowsome) 573.

At Rancho Seco, another B&W plant, a failure of the non-nuclear r

i instrumentation power supply precipitated a loss of feedwater and also comprised the autostart of the emergency feedwater system.

(Tr. 16,913, Rowsome)

L 579.

The Staff testified that the limited case of the analysis of the emergency feedwater system at TMI-1 was not asebroad as I

i

)

.. w e -.

.y

~.... ~ =

9_

-237-the typical IREP studies that have been done.

A typical IREP

[

study would be more intensive or of greater depth in the sense that such a-study would include all of the support systems of r

the emergency feedwater system.

An IREP study would be capable of l

detecting common.cause.vul'ne'rabi'litiesithat' might' link the initiating event with the emergency feedwater-failure through the support f

systems.

A study of only the EFW system cannot do this.

,;j (Tr. 16,919, Rowsome) 580.

The Staff has identified three potential common made linkages that could constrain the reliability with which a plant can deal with a loss of feedwater.

Only'one of these has been corrected at.TMI-1.

(Tr. 1G',920-2f, Rowsome) 581.

The staff testified that these are several different ways l,

to identify common cause failures.

Prggriss has been made in F

modeling seismically-induced failures, fire and floods.

Models t

. lf for failures in similar equipment due to common design, manufacture iC EE and maintenance have been developed. ;The Staff also testified l Em

! I[

that use of these will be a good technique for inves.tigating l t interactions between safety and nonsafety systems.

(Tr. 16,914,

! )

Rowsome)

I 582.

The sole basis advanced by the Staff for not requiring a reliability assessment and systems interaction study prior to restar.t of TMI-l is that they have not made up their minds yet l H l

on the best methodoly to apply and the criteria to be used in l

judging the results.

(Tr. 15,618, Ross; Tr. 16,915, 16,923, i

l Rowsome)

I 1

-y I

f d

1 y-w o

1.

F

-238-583. When asked specifically why the Staff believes that a reliability assessment and a systems interaction study are not required prior to restart. or, aI.ternatively, why the ' items resolved are suf ficient to allow restart., the Staff provided no credible answer.

The Staff could only reiterate the process by which the Action Plan was developed and their future plans which may eventual laad to a requirement for such studies.

(Tr. 15,622-30, Ross) s 584. The Staff classifies Action Plan items II.E.2.1, II.E.2.2, 1

  • and II.E.2.3 as "NA" - action item does not apply to licenses or the item may ultimately lead to new requirements, but in a manner not yet determined by the Staff.

(Ross, ff.tr. 15,555 at Table 1

'and Figure 1) 585.

The three items involve the emergency core cooling system.

The Action Plan states that the objectives are to: decrease reliance on the emergency core cooling system (ECCS) for other L

f than loss-of-coolant accidents; ensure that the ECCS design-basis C.'

$}

reliability and performance are consistent with operational ex-m_['

perience; reach better technical understanding of ECCS performance; y

and ensure that the uncertainties associated with the prediction

. l of ECCS performance are properly treated in small-break evaluations.

(NUREG-0660, at II.E.2-1) 586. We can divine no basis, and the Staff supplied none, for concluding that these items need not be resolved.. prior to restart,1 especially in the face of the lesson learned that the frequency 1

e i

.g

.. ~...

.m

t

-239-with which'some safety systems such as ECCS are called upon to function for reactor coolant system pressure or volume control may exceed their generally understooc and previously accepted design basir.

(NUREG-0 578, at 6) i 587.

The Staff also classified Action Plan itens II.E.3.2, il I

II.E.3.3, II.E.3.4, and II.E.3.5 as "NA" items.

(Ross, ff.tr.

"I.5',555, at " Table 1)

  • F *' " ' ' * ~ " " ' ' ' '

588.

The objective of these Action Plan items is to improve the 1

reliability and capability of nuclear power plant systems' for removing i

decay heat and achieving safe shutdown conditiens following

.J' transients and under postaccident conditions.

(NUREG-06 6 0, at II.E.3-1)

p.

589.

Item II.E.3.2 involves a study using deterministic ahd probabilistic methods to identify design weakr sses and possi. ole decay heat removal system modifications that could be made to I

improve the capability and reliability of these systems under l

ECi all shutdown conditions.

(Id.)

e Ih 590.

Item II.E.3.3 envisions a coordinated effort to evaluate E

shutdown heat removal requirements in a comprehensive manner which is required to permit a judgement of adequacy in terms of overall L

system requirements.

(Id., at II.E.3-2) l

  • Item II.E.3.1, Reliability o# Power Supplies for Natural Circulation is the subject of UCS Contentions 3 and 4.

V

,' i,:- d. L./.r.

.. w

.a g..s..-.

. ~........... -. >

....e.,.

-240-591.

Item II.E.3.4 involves a research project to study the usefuir.ess of installing an additional decay heat removal system in existing plants to improve the overall operational reliability of decay heat removal and to produce system performance and Jafety design criteria for decay' heat. removal systems.

(Id.)'

592.

Item II.E.3.5 involves issuing a revision to Regulatory Guide 1.139, " Guidance for Residual Heat Removal to Achieve and Maintain Cold Shutdown", which includes requirements for reaching cold shutdown using safety-grade equipment.

(Id., at II.E.3-3) 593.

The Staff testified that its current position is that plants should be capable of going to cold shutdown with safety grade equipment, but implementation of that " position" varies from plant to plant.

( Tr..

3079, Silver) 594.

The Staff does not, at this timej have a requirement that operating plant: must implement this position.

Ever. though L.

deficiencies have been identified, the Staff has not issued backfit r-C L_

orders.

(Tr. 8000, Silver) r t.,

5:

595.

TMI-l is not capable of achieving cold shutdown conditions using only sa:vty grade equipment.

(Supra., para 400) 596.

The Staff provided no basis for concluding that these Action Plan items pertaining to decay heat removal do not need to be resolved crior to restart.

I 597.

We have decided that it is unnecessary to set forth here I

a discussion of the substance of each of the Action Plan items which the Staff classifies as not applicable at this tin.e to

'*G*

eed e

omaa A )

wwd*

..m w

wa

j

-241-TMI-1.

The discussion above is sufficient to illustrate that the main reason the Staff classsifies these items as not applicable at this time is that the new requirements that may result from resolving the "not applicable" items have simply not yet been determined.

This, of course, does not provide a basis for concluding that the Action Plan. items completed to date are sufficient to allow TMI-l to reset 2nn.

598.

We also find that the Action Plan itself contradicts the Staff's testimony that the "NA" items would not provide the most significant safety improvements.

.=39.

The Action Plan contains a priortcy ranking for each of its items.

The priority ranking system assigned a maxi =um of 210 possible points of which only 100 involved an assessment of the Safety significance of the item.

Ihe remainder of the points involved the cost of implementation, the length of time required hg, for implementation, and whether the item involved hardware or C

gg; human element improvements.

(Tr. 8101-02, Pollard; NUREG-0660, b

at Table 3.1)

I 600.

With respect to the assessment of safety significance, the l

Action Plan assigned 100 points to items with "high" safety I

significance and 50 and 0 points to those items with " medium" and " low" safety significance.

(NUREG-0660, at Table 3.1)

]

i.

601.

Of the 126 Action Plan items which the Staff classifies as "NA" (i.e.,

item does not apply to licensees or the item may ultimately lead to new requirements, but in a manner not yet determined by the Staff),

approximately 30 items-have a "high" safety significance and approximately 40 have a " medium'.' safety D.

e w w_%

.~m.

..-.e.

m _.n

=*

e

-243--

4 1 significance assigned in'the Action Plan.

(Compare Ross, ff. tr.

15,555, Table 1 with NUREG-0660 Table 3.3) 602.

Since the Staff has not yet-determined the extent to which these

~

Action Plan items may result in new requirements, we cannot deter-mine the basis, if any, for the Staff's conclusionary testimony that the Action Plan items applicable to TMI-l will provide the most significant safety improvement and, therefore, give no weight to that testimon3 603.

We now turn to a discussion of the record with respect to the Staff's' basis for deciding which of the Action Plan items it

)

classifies as applicable to TMI-l should be required'to be implemented prior to restart-604.

As we noted above, the thrust of the Staff's direct :

testimony was that those Action Plan items which are both applicable to TMI-l and required to be impleted prior to restant are sufficient to allow restatt.

(Ross, ff. tr. 15,555, at 3,12) ir_.

605.

The Staff defined this subset.of Action Plan items as the E"-

1C combination of the "short-term actions" required' by the Commission's k-F August 9, 1979 Order and the items identified in NUREG-0694 as being necessary prior to issuance of a fuel load or full power license.

t I

(Id., at 12) 606.

The Staf f noted that the Commission's August 9, 1979:. order specifying which items were "short-term" and which were "long term" L.

was issued prior en the completion of many of the TMI-2 accident investigations and development of the Action Plan.

(Id., at 8)

Thus,'it cannot be claimed that the Commission itself was.in a position to decide on the merits which actions were sufficient to

,.g U#

.. e. 7 # <

..#.4

%

  • e'*

2.*..

m..

't b

l

-243-allow restart.

To the contrary, ?h? Commission directed this Board to determine the issue subject to Commission review.

607.

The Staff also testified that the remainder of the Action Plan' items applicable.to TMI-1 which will not be implemented prior

  • to restart, will be: required to be completed on a schedule con-s sistent with that specified in NUREG-0737 for operating reactors.

l (Id., at 12) 608.

The Board inquired into the bases for delaying certain items until after. restart-The Staff's basis. for determining whether the dates: proposed'.for. TMI-l arc. acceptable focused more on expediency than on an assessment of the risk to public health and safety.

609. Action Plan item I.C.1, "short-t rm accident analysis and procedures revision", includes requirements to perform analyses ii of transients and accidents, prepare emergency procedure C.

!E guidelines, upgrade emergency procedures and conduct operating n-I retraining.

" Emergency procedures are required to be consistent t

with the actions necessary to cope with the transients and j

accidents analy rd."

(NUREG-066 0, at I. C-2 to I.C-3) 610. The original schedule for these requirements was to analyze transients and accidents by early 1980 and implement the emergency procedures and retraining within three months-after the emergency procedure guidelines were established.

(Id., at I.C-3)

I 4

I

-244-611.

The Staff modified this "dealine" to the first refueling outage after January 1, 1932 for the training and procedures resulting from the transient.and accident evaluation.

(Tr. 15,534, s-Capra) 612.

As an " interim approach" to compensate.for not completing,

'this item, the Staff is relying on Action Plan item I.C.8, which

~~'is a pilot monitoring program of selected emergency procedures.

(Tr. 15,587-88, Capra) 613.

However, review of procedures at licensed plants has dis-closed difficiencies.

The Staff has gone through p'Eocedures with operators and found instances where the operator could not physically I

  1. ollow the procedure because controls were too far apart.

On other occasions the operator literally did not know what to do next.

(T".

15,732-33, F ss) 614.

Nevertheless, the Staff is not rbviewing any more than four selected emergency procedures at TMI-1.

(Tr. 15,588, Capra)

Furthermore, there appears to have been only a cursory review of

{-

the selected emergency procedures and 'no check on subsequent re--

visions to the procedures.

(Tr. 16,771-775, Wermiel)

Such a

{,

situation neither compensates for not completing item I.C.1 nor 7

provides a basis for concluding that what has been accomplished to date is sufficient to allow restart.

615.

There are several items not being requi:edf prior to restant f

solely because of equipment delivery problems.

The Staff was quite candid under examination in stating that if the licensee cannot buy a necessary piece of equipment prior to restart, the-7

~

l t

, :..;n L;.L.

a::..'n mm:: van.

~.

...n,

..:. w..

a

1.

-245-o staff approved a deadline for implementing the Action Plan. item I

consistent with the time when the equipment coulc be purchased.

(Tr. 15,676, Ross) g 616.

The Staff also testified that in deciding what was "necessary" t

prior to restart, their decision was ". tempered" by their perception of what is "possible."

(Tr. 15,677-78,. Ross)

Z'--

. ~

617.

The Staff further testified that this concept of " necessity" depends not only upon "possible" and " feasibility", but also on j

the "pragmatics" of balarcing safety against the generation of electricity.

(Tr. 16,681-82, Ross) f 618.

In other instances the Staff, to a large degree, simply considered what the licensee planned to do anyway - this is, with-out the Staff requiring that something.lus done.

(Tr. 15,683-84, Ross) i 619.

Among the Action Plan items which the Staff proposes not s);

to require prior to restart because of equipment procurement c~

p.

problems are the following:

b (1)

Item II.B.1, installation of reactor coolant F

system high point vents (Tr. 15, 517-99, iy Ross and Capra);

i~

(2)

Item II.B.3, post-accident campling (Tr.

15,602, Ross);

(3)

Item II.E.4.2, containment isolation dependability r.

(Tr. 15,607-09, Ross and Capra);

(4)

Item II.F.1, additional accident monitoring equipment (Tr. 15,609-10, Ross); and j

T

^

  • s g9

.... x...;w u

-246-(5)

III.D.3.3, inplant radiation monitoring to measure iodine accurately (Tr. 15,612-15, Ross and Capra) 620.

All of these five items were classified as either "high or

" medium" safety significance items in the Action Plan.

(NUREG-0660, at Table B.3) l 621.

In summary, the record indicates that the Staff has no basis for deciding whether the items which have been completed

~

arei sufficient. to allow restart Tha Staff'has taken.two.

l-l approaches.

For those items where the requirements for improved safety are known but not implemented, the Staff has simply post-

[

poned the deadline without providing a reasoned basis for con-cluding that the health and safety of the public will not be en-dangered.

For those items where the Staff has not yet determined what requirements are necessary to resolve the lesson learned from.

the TMI-2 accident, the Staff simply describes its ongoing research and evaluation plans to resolve the item.

t.

s 1c-622.

This latter approach is analagous to the Staff's earlier wm.

Ih treatment of generic unresolved safety problems.

This practice woe specifically rejected by the Appeal Board in Biver Bend and North Anna.*

It also was a subject of the Report by the President's I

Commission on the Accident at Three Mile Island:

"NRC's primary focus is on li' censing and insuf ficient

~~

attention has been paid to safety.***L T 7 he evidence

' L

' See the discussion supra at paras 544 - 546.

Having identified safety problems which remain unresolved does not absolve the Staff or Licensee from demonstrating why the plant can be safely operated pending resolution of these safety problems, wheter generic or not.

f.

,t 4

1

% J y,.g

,a 4%..

e.

.i-

-247-indicates that the labeling of a problem as ' generic ' =ay, provide a convenient way of postponinc iacision-on a difficult problem".

(Keneny, at 20) 623.

"The [ President's] Commission celieves that the agency must improve on prior perfremance in resolving generic and specific safety issues."

(Kemeny, at 64) p 624.

The Staff has done no plant - specific analysis of TMI-1 to 1.

1 determine whether the plant is safe enough to restart.

(Tr.21,117, 21,120-1 Silver: Tr. 21,154, Jacobs)

Despite the fact that the

!I Staff recognizes that license conditions must be imposed by the

.I

}

Board, and that only two weeks remained for submitting the Staff's proposed findings, the Staff lad not yet determined even what license conditions it would propose to the Board and seemed to have given no thought to tho question until it wa's raised on cross-examination.

(rr. 21,442-3, 21,260-3, Silver)

+

'N r;

625.

The Staff appears to be operating on the simple proposition W

5:

that if other plants. ara being permitted to continue to operate L.

with similar defets to TMT-1, ergo, TMI-l can restart.

(Tr. 21,020, L

i Silver)

,F 626 We were frankly astonished to hear that items which were l

listed by the Staff as " required" prior to restart, were not, in fact, required.

They appear on the list simply., because the current L

implementation dates in NUREG-0737 happen to fall before the pro-jected rer, tart date.

If the 0737 dates slip beyond restart, those items will not be required by the Staff.

No evaluation was made of any of the items. co determine whether they are necessary for safety-o ki a

3

-248-for Ti1I-l.

(Tr. 21,217 - 321, Silver) 627.

Moreover, all deadlines are considered amendable b, the Staff.

Nothing is seen as so important to safety that it should be a hard and fast requirement.

(Tr. 21,045-8, Silver)

The Staff states that all deadlines beyond June 30, 1981 are subject to reconsideration and the Staff doesn't know whether any are firm (Tr. 21,236, 21,136, Silver) 628.

While the Staff stated that it would require a justification or " explanation" before allowing extensions of deadlines for com-pletion of requirements, it has already allowed such a waiver of p

committment as to the installation of the high point vents with o

no apparent justification.

(Tr. 21,282-5, 21,297, 21-312-13, Silver and Jacobs)

Thus, the Board cannot rely on the promise that good cause wi ll be required to justift an extension.

629.

We are unable to discern any coherent logic behind the Staff's OE~

cosition that there is reasonable assurance that this plant is E

w..

sate enough to restart (Staff Ex. 14 at 3) or that the measures b

recommended by the Director of NRR are sufficient to permit operation.

t In fact, the Board cannot tell from this record what are " require-r>

ments" for restart.

Nor can we rely on Licensee "committments" 7

to fill this void, since it is quite clear that such committments are unenforcear.le, are routinely permitted to be changed as NUREG-0737 deadlines are changed, and simply march in lockstep with NUREG-0737.

(Tr. 21,282 - 21,294, Silver)

They have no independent i

force whatever.

630.

On the basis of the foregoing, the Board concludes that this s

o

-249-record does not establish that there is reasonable assurance i

f the the TMI-l is safe enough to restart or that the short and

{

long-term measures recommended by the Director of NRR are s

sufficient to provide reasonable assurance that TMI-l can be operated without endangering the health and safety of the b

public..

~

i r

e L

Fc.

2" w

K.

k m.

w 6

k I>

L I s b

9

I

\\91llh Y

O g

ogtlf[

UNITED STATES OF AMERICA 9

jQN 1 g $@ '

NUCLEAR REGUALTORY COMMISSION

. ~

E""

'y w+

tf's.,(,. & Ser.

d o

BEFORE THE ATOMIC SAFETY AND LICENSING B

/f n

In the-Matter of

)

)

METROPOLITAN EDISON COMPANY

)

Docket No. 50-289

)

(Restart)

(Three Mile Island Nuclear

)

Station, Unit No. 1)

)

I hereby certify that copies of " Union of Concerned l

Scientists Proposed Findings of Fact and Conclusions of Law

[

on UCS Contentions Nos. 13 and 14 and Board Questions 2 and 6 have been mailed postage pre-paid this 12th day of June, 1981

'3, to the parties listed below.

SERVICE LIST Ivan M.

Smith, Esquire (5)

John A'.

Levin, Esquire Chairman Assistant Counsel Atomic Safety and Licensing Penns lvania Public Utility Commission Board Panel Post Office Box 3265 O.

S.

Nuclear Regulatory Harrisburg, Pennsylvania 17120

[

Commission g

washington, D. C.

20555 k_

g' Dr. Walter H.

Jordan Robert Adler, Esquire Atomic Safety and Licensing Assistant Attorney General Board Panel 505 Executive House 881 West Outer Drive Post Office Box 2357

{

Oak Ridge, Tennessee 37830 Harrisburg, Pennsylvania 17120 i

Dr. Linda W.

Little Walter W.

Cohen, Esquire Atomic Safety and Licensing Consumer Advocate Board Panel Office of Consumer Advocate 5000 Hermitage Drive 14th floor, Strawberry Square Raleigh, North Carolina 27612 Harrisburg, Pennsylvania 17127 h

James R.

Tourtellotte, Esq.

Docketing and Service Section Office of the Executive Office of the Secretary Legal Director U.S.

Nuclear Regulatory Commission U.S. Nuclear Regulatory Washington, D.

C.

20555 Commission Washington, D.

C.

20555 f

i

)

+

4

~

i!$.

5 i

. Jordan D. Cunningham, Esquire William S.

Jordan, III, Esquire-Fox, Farr & Cunningham Harmon & Weiss 2320 North Second Street 1725 Eye Street, N.W.,

Suite 506 Harrisburg, Pennsylvania 17110 Washington, D.

C.

20006 Mrs. Louise Bradford Chauncey Kepford/ Judith Johnsrud TMI ALERT Environmental Coalition on Nuclear 315 Feffer Street Power Harrisburg, Pennsylvania 17102 433 Orlando Avenue State College, Pennsylvania 16801 Steven C. Sholley Union of Concerned Scientists Marvin I.

Lewis 1725 I Street, N.W.,

Suite 601 6504 Bradford Terrace Washington, D.

C. 20006 Philadephia, Pennsylvania 16801 Gail Bradford Attorney General of New Jersey ANGRY Attention:

Thomas J.

Germine, Esq.

j 245 West Philadelphia St.

Deputy Attorney General York, Pennsylvania 17404 Division of Law - Room 316 1100 Raymond Boulevard Marjorie M. Aamodt Newark, N.

J.

07102 R.D.

5 Coatesville, Pennsylvania 19320 George F.

Trowbridge, Esq.

Shaw, Pittman, Potts & Trow-t bridae

~)

1800 E Street, N.W.

1 Washington, D.

C. 20036 t"

w ar_.

?

f Eflyn RS/ Weiss

~

.L

~

-.