ML19338G199

From kanterella
Jump to navigation Jump to search
LER 80-053/03L-0:on 800926,during Maint Shutdown Period, Seminannual Test of Standby Diesel Generators Revealed Inoperability of 1B Programmer.Caused by Faulty Wire Position Which Impeded Relay Contact.Wire Repositioned
ML19338G199
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 10/24/1980
From: Gahm J
PUBLIC SERVICE CO. OF COLORADO
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
Shared Package
ML19338G161 List:
References
LER-80-053-03L, LER-80-53-3L, NUDOCS 8010280586
Download: ML19338G199 (1)


Text

.. .

e '*

NRC PORM 366 U. S. NUCLEA2 REtULATO".Y COMMIS$10N (7 771-LICENSEE EVENT REPORT CONTROL BLOCK: l l l l l l l@ (PLEASE PRINT OR TYPE ALL REQUIRED INFORMATION) lo lil8I 9C l 0LICENSEE 7

l F l Coog S l V l 1 l@l 0 l0 l- l LICENSE to 15 0 l0 NUMSE l0 l0A l0 l- l0 l025 l@l4 26 l1LICENSE l1 l2TvrE l0JOl@l$7 CAT 64l@

l CON'T lolil 3{,CE l L @l 0 ] 5 l0 l010 l 2 l 617 @l019 69 l216 l 8 l0 l@l1 l0 74 75 l2 l4 l8 l080l@

RgPoRT cATE 7 8 60 61 coCKETNuMBER 68 EVENT cATE EVENT OESCRIPTION AND PROS ABLE CONSEQUENCES h l o I:1 l On September 26. 1980, during a maintenance shutdown period, the semi-annual test of l  ;

I o l a i i the standby diesel generators and associated automatic load shedding and pro- l I o t 4 I l gramming equipment revealed that 1B progra=mer did not operate. The redundant 1A pro-l laisl l grammer was operable and available. Reportable as a degraded mode of LCO 4.6.1d)3 perl l o l6 ! l Fort St. Vrain Technical Specification AC 7.5.2(b)2. There was no affect on public l I

l o 17 I l health or safety. No similar occurrence. l 10681I l 7 ea a0 i

  • E3t To'o'E sLsC$$E CowPoNENTCooE E stsYo'oE suYoEE loIal l E l D l@ W@ lC l@ l Rl El Ll Al Yl ' Xl@ ' l Fj@ W @

sEcutNTAL OCCURRENCE RE* ORT 4EVisloN LE4 EVENT YE AR REPonT No. CooE TYPE No.

@ 4Eg'uo y l8 l0 l 21 22 l-l 23 l 015 l 3 l 24 ;6 l/l 27 10 l 3 l 23 29 lL l JJ l-l 31 W32 K N AC oN C Pt NT ME M MouRs SS i PoR 9. SuPPLI MAN PC RER lXl@l2l@ lZl@

43 34 45 W@

36 l0l0l0l0l 31 40 lY l@

el l42N l@ l43N l@ l G l 0 l 8 l 0 l@ ;

44 47 CAUSE MSCRIPTION AND CORRECTIVE ACTIONS h IiloliThe failure of 1B program was due to a wire which interfered with the coeration of onel ii ;i i l relay contact. It appears that the wire was inadvertently repositioned. The wire wasi I

,,,,,l repositioned to prevent interference. The other wires on this relay were checked.  ;

g l Personnel =a 'e aware of the situation. The surveillance test was satisfactor11.y l

,,,,,lco=pleted. P iay type GE-HEA. l 7 3 3 90

'sT A  % PoWEP oTHER STATUS i o RY DISCOVERY oEsCRIPT oN l li is I l cl@ l0 l 0 l J@[N/A

' 8 it o 44 l lesB l@lasSeni-Annual Surveillance Test a0 l l AduviTv Co'$ TENT mELEAsE AucuNT oP ACriviry @ l LoCATtoN oP RELEASE @

l i I 5al9 l Z l @o oP aELEAstl Z l@l N/A l N/A l l

7 10 11 44 45 30 PERSONNEL EXPOSURES NUMBER TYPE oEsCRIPT1oN l t 171 ] 0 l 0 l 0 l@l Zl@l N/A l

' ' PeRsoNNE'L iNau'R'iEs ,

NoveER oEsCRiPricN@ l li Ia 4i 10l 7 3 0l 01@l12N/A 11 80 l

'si'E "OSEsCRPT!o'N ** " @

li 191 4 9 l Zl@l N/A to 80 l

ISS of CRIPTioM

  • 12 l o l LSuE81N/A I IIIIIIIIIIIIli AME OP PREPARER PHONE: 03 785-2224 2 8 010 80 F% 7

~

j