05000325/LER-1980-067, Forwards LER 80-067/03L-0

From kanterella
(Redirected from ML19338D736)
Jump to navigation Jump to search
Forwards LER 80-067/03L-0
ML19338D736
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 09/16/1980
From: Tollison A
CAROLINA POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19338D737 List:
References
BSEP-80-1504, NUDOCS 8009230709
Download: ML19338D736 (1)


LER-1980-067, Forwards LER 80-067/03L-0
Event date:
Report date:
3251980067R00 - NRC Website

text

.

Carolina Power & Light Cortpany Brunswick Steam Electric Plant P. O. Box 10429 Southport, N. C. 28461 September 16, 1980 FILE: B09-13516 SERIAL:

BSEP/80-1504 Mr. James P. O'Reilly, Director U. S. Nuclear "egulatory Commission Region 11, Suu 3100 101 Marietta S' eet N.W.

Atlanta, GA 30303 BRUNSWICK STEAM ELECTRIC PLANT, UNIT NO. 1 DOCKET No. 50-325 LICENSE : 0. DPR-71 LICENSEE EVENT REPORT l-80-67

Dear Mr. O'Reilly:

In accordance with Section 6.9.1.9b of the Technical Specifications for Brunswick Steam Electric Plant, Unit No. 1, the enclosed Licensee Event Report is submitted. This report fulfills the requirement for a written report within thirty (30) days of a reportable occurrence and is in accordance with the format set forth in NUREG-0161, July 1977.

Very truly yours, f

f A. C. Tollison, Jr., General Manager Brunswick Steam Electric Plant RMP/bkd Enclosure cc:

Mr. R. A. Hartfield Mr. V. Stello, Jr.

[bol s

///

800 esso yo9 3