05000325/LER-1980-002, Forwards LER 80-002/03L-0

From kanterella
Jump to navigation Jump to search
Forwards LER 80-002/03L-0
ML19257D819
Person / Time
Site: Brunswick 
Issue date: 01/30/1980
From: Tollison A
CAROLINA POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19257D820 List:
References
BSEP-80-188, NUDOCS 8002060538
Download: ML19257D819 (1)


LER-1980-002, Forwards LER 80-002/03L-0
Event date:
Report date:
3251980002R00 - NRC Website

text

.

U t-3 Carctina Po.<er t. L;gnt Company Brunswick Steam Electric Plant P. O. Box 458 Southport, NC 28461 January 30, 1980 FILE: B3516 SERIAL:

BSEP/80-188 Mr. James P. O'Reilly, Director U. S. Nuclear Regulatory Commission Region II 101 Marietta Stree*., Suite 3100 Atlanta, GA 30303

.lRUNSWICK STEAM ELECTRIC PLAN'?, UNIT NO. 1 DOCKET No. 50-323 LICENSE NO. DPR-71 LICENSEE EVENT REPORT 1-80-2

Dear Mr. O'Reilly:

In accordance with Section 6.9.1.9b of the Technical Specifications for Brunswick Steam Electric Plant, Unit No. 1, the enclosed Licensee Event Report is subaitted. This report fulfills the requirement for a written report within thirty (30) days of a reportable occurrence and is in accordance with the format set forth in NUREG-0161, July ?.977.

Ver y yours, A. C. Tollison, Jr., General Manager Brunswfck Steam Electric Plant RMP/mcg Enclosure cc: i Mr. R. A. Hartfield Mr. V. Stelle 1928 204 v

8002060 5 3 E'