ML19106A236
| ML19106A236 | |
| Person / Time | |
|---|---|
| Site: | 07000925, 07003073 |
| Issue date: | 09/04/2001 |
| From: | Bauer T Oak Ridge Institute for Science & Education |
| To: | Garcia E NRC Region 4 |
| Shared Package | |
| ML19106A222 | List: |
| References | |
| Download: ML19106A236 (34) | |
Text
OAK RIDGE IN STITU TE FOR SCIENCE A N D EDUCATION September 4, 2001 Emilio M. Garcia U.S. Nuclear Regulatory Commission Region IV Harris Tower 611 Ryan Plaza Drive Suite 400 Arlington, TX 76011-8064
SUBJECT:
FINAL REPORT-CONFIRMATORY SURVEY OF PIT 4, SURVEY UNIT 3 OF THE CUSHING REFINERY
Dear Mr. Garcia:
Enclosed is the final report for the confirmatory survey of Pit 4, Survey Unit 3 of the Cushing Refinery Site, Cushing, Oklahoma. Comments provided on the draft report have been incorporated.
Please contact me at (865) 576-3356 or Timothy J. Vitkus at (865) 576-5073 should you have any questions.
Sincerely,
~ / '/ ~
-/
/ -
-// //
~.
/.
_.--,:~ --
(
.,,,,..,/"
Timothy J. Bauer _
Assistant Project Leader Environmental Survey and Site Assessment Program TJB:klp Enclosure cc:
G. Purdy, NRC/NMSSffWFN 7F27 E. ~ox-Davin, NRC/NMSS/fWFN 8A23 W. Beck, ORJSE/ESSAP E. Abelquist, ORISE/ESSAP T. Vitkus, ORJSE/ESSAP File/791 P. 0. BOX 117, OAK RIDGE, TENNESSEE 3783 1*01 17 Operated by Oak Ridge Associated Universities far the U.S. Department al Energy
CONFIRMATORY SURVEY OF PIT 4, SURVEY UNIT 3 OF THE CUSHING REFINERY SITE KERR-MCGEE CORPORATION CUSHING, OKLAHOMA T.J. BAUER Prepared for the Region IV U. S. Nuclear Regulatory Commission
The Oak Ridge Institute for Science and Education (ORISE) was established by the U.S. Department of Energy to undertake national and international programs in education, training, health, and the environment. ORISE and its programs are operated by Oak Ridge Associated Universities (ORAU) through a contract with the U.S. Department of Energy. Established in 1946, ORAU is a consortium of 88 colleges and universities.
NOTICES The opinions expressed herein do not necessarily reflect the opinions of the sponsoring institutions of Oak Ridge Associated Universities.
This report was prepared as an account of work sponsored by the United States Government. Neither the United States Government nor the U.S. Department of Energy, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe on privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, mark, manufacturer, or otherwise, does not necessarily constitute or imply its endorsement or recommendation, or favor by the U.S.
Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the U.S. Government or any agency thereof.
CONFIRMATORY SURVEY OF PIT 4, SURVEY UNIT 3 OF THE CUSIDNG REFINERY SITE KERR-MCGEE CORPORATION CUSIDNG, OKLAHOMA Prepared by T. J. Bauer Environmental Survey and Site Assessment Program Oak Ridge Institute for Science and Education Oak Ridge, Tennessee 37831-0117 Prepared for Region IV U.S. Nuclear Regulatory Commission FINAL REPORT AUGUST2001 ORISE 01-1093 This report is based on work performed under an Interagency Agreement (NRC Fin. No. A-9093) between the U.S. Nuclear Regulatory Commission and the U.S. Department of Energy. Oak Ridge Institute for Science and Education performs complementary work under contract number DE-AC05-000R22750 with the U.S. Department of Energy.
Kerr-McGee Corp. -August 15, 2001 y:essap\\project\\0791 \\finalreportPit4Cushing.doc
CONFIRMATORY SURVEY OF PIT 4, SURVEY UNIT 3 OF THE CUSHING REFINERY SITE KERR-MCGEE CORPORATION CUSHING, OKLAHOMA
~~~
/.~
Prepared by: _...,.,L.A!.~~~-.:a.....-~-E~"""'-"-----*---------- Date:.StZI /20() I r..CBauer, Assistant Project Leader Environmental Survey and Site Assessment Program
, Survey Projects Manager Environmental Survey and Site Assessment Program Reviewed by: ___ tj?
___
- _. _D._......... _____;;;~;.......-..-=--;;..;;;._--------- Date: g/?-?-Jo I R. D. Condra, Laboratory Manager Environmental Survey and Site Assessment Program Reviewed by: __ a__
___ /_P_~
__________ Date: g }.).~ fo I A. T. Payne, Quality M~
Environmental Survey and Site Assessment Program E. W. Abelquist, Asso
- e Program Director Environmental Survey and Site Assessment Program Reviewed by: _....~'--------==--*
-________ Date:~~
W. L. Beck, Program Director Environmental Survey and Site Assessment Program Kerr-McGee Corp. - August 15, 2001 y:essap\\project\\0791 \\finalreportPit4Cushing.doc
ACKNOWLEDGMENTS The author would like to acknowledge the significant contributions of the following staff members:
Kerr-McGee Corp. -August 15, 2001 FIELD STAFF T. L.
Brown LABORATORY STAFF R. D. Condra J.
S.
Cox W. P.
Ivey C. M. Brown CLERICAL STAFF D. K. Herrera K. L.
Pond A. Ramsey ILLUSTRATOR T. D. Herrera y:essap\\project\\0791 \\finalreportPit4Cushing.doc
TABLE OF CONTENTS PAGE List of Figures................................................................................................................................. ii List of Tables.................................................................................................................................. iii Abbreviations and Acronyms......................................................................................................... iv futroduction and Site History.......................................................................................................... 1 Site Description............................................................................................................................... 2 Objective......................................................................................................................................... 3 Document Review........................................................................................................................... 3 Procedures....................................................................................................................................... 3 Sample Analysis and Data futerpretation........................................................................................ 4 Findings and Results....................................................................................................................... 4 Comparison of Results with Guidelines.......................................................................................... 5 Summary......................................................................................................................................... 6 Figures............................................................................................................................................. 7 Tables................................................................... '......................................................................... 11 References..................................................................................................................................... 14 Appendices:
Appendix A: Major fustrumentation Appendix B: Survey and Analytical Procedures Appendix C: Guidelines for Residual Concentrations of Thorium and Uranium Wastes in Soil Kerr-McGee Corp. -August 15, 2001 y:essap\\project\\0791 \\finalreportPit4Cushing.doc
LIST OF FIGURES PAGE FIGURE 1:
Location of the Kerr-McGee Corporation Site, Cushing, Oklahoma................................................................................................. 8 FIGURE 2:
Location of Pit 4, Cushing Refinery Site................................................................. 9 FIGURE 3:
Cushing Refinery Site, Pit 4, Survey Unit 3-Sampling Locations........................ 10 Kerr-McGee Corp. - August 15, 2001 ii y:essap\\project\\0791 \\finalreportPit4Cushing.doc
LIST OF TABLES PAGE TABLE 1:
Uranium and Thorium Concentrations in Soil Determined by Gamma Spectroscopy........................................................................................... 12 TABLE 2:
Uranium Concentrations in Soil Determined by Alpha Spectroscopy.............................................................................................. 13 Kerr-McGee Corp. - August 15, 2001 111 y:essap\\project\\0791\\finalreponPit4Cushing.doc
µR/h AEC cm DOE EML ESSAP ITP kg KMC m
m2 MAPEP MDC MeV Nal NIST NRC NRIP ORISE pCi/g RMA Kerr-McGee Corp. -August 15, 2001 ABBREVIATIONS AND ACRONYMS microroentgens per hour Atomic Energy Commission centimeter Department of Energy Environmental Measurements Laboratory Environmental Survey and Site Assessment Program lntercomparison Testing Program kilogram Kerr-McGee Corporation meter square meter Mixed Analyte Performance Evaluation Program minimum detectable concentration million electron volts sodium iodide National Institute of Standards and Technology U.S. Nuclear Regulatory Commission NIST Radiochemistry Intercomparison Program Oak Ridge Institute for Science and Education picocuries per gram radioactive material area iv y:essap\\project\\0791 \\finalreportPit4Cushing.doc
CONFIRMATORY SURVEY OF PIT 4, SURVEY UNIT 3 OF THE CUSIDNG REFINERY SITE KERR-MCGEE CORPORATION CUSIDNG, OKLAHOMA INTRODUCTION AND SITE HISTORY The Cushing refinery site is located two miles north of the City of Cushing in Payne County, Oklahoma and was operated from 1915 to 1972. Kerr-McGee Corporation (KMC) purchased the Cushing site from General American Oil Company of Texas in 1956 and operated an oil refinery there from 1956 to 1972. From 1962 to 1966, KMC used part of the Cushing refinery site to process natural thorium and natural, depleted, and enriched uranium under two Atomic Energy Commission (AEC) licenses, SMB-664 and SNM-695.
AEC license SMB-664 was issued to KMC on November 7, 1962 and authorized unlimited quantities in a variety of chemical forms of uranium and thorium. The bulk of uranium material received was UF6 (uranium hexafluoride). Typical products were oxides, carbides, fluorides, nitrates, metal, etc. Thorium material was received in the form of concentrates. Typical products were oxides or carbides or combinations of uranium and thorium compounds at various ratios of thorium to uranium (KMC 1995).
AEC license SNM-695 was issued to KMC on April 23, 1963 and authorized possession of any enrichment of uranium in any form, except metal, including scrap recovery, not to exceed 1000 kilograms (kg) of uranium-235. The uranium was received in the form of UF6 and other chemical compounds and was converted to other compounds of uranium suitable for nuclear fuels. AEC license SNM-695 was amended to permit reduction of high enriched UF4 (green salt) to uranium metal buttons.
Enriched uranium was processed at Cushing from early 1963 until September 1965 and thorium processing was performed from December 1964 until February 1966. In April 1966, KMC reported to the AEC that as of April 26, 1966, all special nuclear material had been transferred from the Cushing site to KMC's new Cimarron facility in Crescent, Oklahoma and that all Cushing buildings in which licensed activities had been performed were cleaned and decontaminated. The AEC conducted a close-out survey of the Cushing facility on July 6, 1966.
Kerr-McGee - August 15, 2001 y:essap\\project\\0781 \\finalreportPit4Cushing.doc
On the basis of this survey, and in response to KMC's request for authorization to release the facility for unrestricted use, licenses SMB-664 and SNM-695 were terminated on July 25, 1966 (KMC 1995).
KMC has performed characterization surveys and subsequent remediation for a large portion of their site. During cleanup activities, some radioactively contaminated materials were placed in burial trenches, old petroleum storage tank dike areas, and part of a hydrocarbon waste impoundment, Pit 4. Pit 4 contained acidic hydrocarbon sludge (heavy hydrocarbon containing sulfuric acid) from the lubricating oil manufacturing operation. Characterization data showed the northern portion of Pit 4 to be non-acidic, which was segregated from the acidic portion and renamed Waste Pit (WP) 30. Uranium was present in low concentrations, near background, throughout Pit 4. Thorium contamination was identified in the northwestern portion of Pit 4, while the remaining portions were near background concentrations.
KMC has remediated Pit 4 and performed the final status survey in accordance with draft NUREG/CR-5849 (NRC 1992). At the request of Region IV of the U. S. Nuclear Regulatory Commission (NRC), the Environmental Survey and Site Assessment Program (ESSAP) of the Oak Ridge Institute for Science and Education (ORISE) performed an independent confirmatory radiological survey of Pit 4, Survey Unit 3. This report summarizes the procedures and results of the survey.
SITE DESCRIPTION The KMC Cushing site is located in Payne County, Oklahoma, two miles north of the City of Cushing. Cushing lies about midway between Tulsa and Oklahoma City. The terrain of the region is rolling, oil-producing pasture land. Several oil fields were developed in the immediate area. The elevation of the refinery site ranges from 250 to 280 meters above sea level. The entire Cushing site encompasses approximately 178 hectares. Figure 1 shows the location of the Cushing Refinery Site.
The Pit 4 excavation (Survey Unit 3), located in Radioactive Material Area 3 (RMA-3) in Sector 4 of the site, and surrounding areas (Survey Units 1 and 2
- and 4 through 7) encompasses a Kerr-McGee-August 15, 2001 2
y:essap\\project\\0791 \\finalreportPit4Cusbing.doc
total area of approximately 41,450 m2* The Pit 4 excavation, Survey Unit 3, has an area of 9075 m2* The location of Pit 4, Survey Unit 3, on the Cushing Refinery Site is shown in Figure
- 2.
OBJECTIVE The objective of this survey was to provide independent radiological data, for use by the NRC, in evaluating the adequacy of the decontamination of Pit 4, Survey Unit 3, relative to the established guidelines.
DOCUMENT REVIEW As part of the confirmatory activities, ESSAP reviewed the licensee's final status survey plan and final status survey sampling data. The radiological survey results were compared to the established NRC guidelines.
PROCEDURES ESSAP performed confirmatory surveys at the KMC site during the period June 25 through 27, 2001. These surveys included independent measurements and sampling of Pit 4, Survey Unit 3.
The surveys were performed in accordance with the ESSAP Survey Procedures and Quality Assurance Manuals and the site-specific survey plan submitted to and approved by the NRC (ORISE 2000 and 2001a and b). Additional information concerning major instrumentation, sampling equipment, and survey and analytical procedures may be found in Appendices A and B.
REFERENCE SYSTEM Sampling locations were referenced to the site grid system and noted on a drawing of Pit 4, Survey Unit 3 provided by KMC.
SURFACE SCANS Surface scans were conducted for gamma radiation over approximately 50% of the excavated area using Nal scintillation detectors coupled to ratemeters with audible indicators.
Kerr-McGee-August 15, 2001 3
y:essap\\project\\0791 \\finalreportPit4Cushing.doc
EXPOSURE RATE MEASUREMENTS Exposure rate measurements were performed at one meter above the surface at each soil sampling location using a microrem meter (Figure 3).
SOIL SAMPLING Surface soil (0-15 cm) samples were collected from 15 randomly selected locations and from one location of elevated direct radiation identified by surface scans (Figure 3).
SAMPLE ANALYSIS AND DATA INTERPRETATION Samples and data were returned to ESSAP's Oak Ridge, Tennessee, facility for analysis and interpretation. Laboratory analyses were conducted in accordance with the ESSAP Laboratory Procedures Manual (ORISE 2001c). Soil samples were analyzed by solid-state gamma spectroscopy for the uranium isotopes U-238 and U-235 and the natural thorium isotopes Th-228 and Th-232. Spectra were also reviewed for any other identifiable photopeaks. Five soil samples were analyzed by alpha spectroscopy to determine the isotopic abundances of the uranium. Soil sample results were reported in units of picocuries per gram (pCi/g) dry weight. Exposure rate measurements were reported in microroentgens per hour (µR/h).
FINDINGS AND RESULTS DOCUMENT REVIEW ESSAP's review of the licensee's documentation indicated adequate and appropriate procedures and methods were employed to document the overall radiological status of Pit 4, Survey Unit 3.
Final status survey data showed remediation of Pit 4, Survey Unit 3 had reduced uranium and thorium concentrations in soil to levels less than the NRC criteria for release for unrestricted use.
SURFACE SCANS Surface scans identified one area of elevated direct gamma radiation. An area, primarily in Grid Block 79 (Figure 3), produced a response near two-times the background response. Sample 13 was collected at the point of the highest gamma response.
Kerr-McGee-August 15, 2001 4
y:essap\\project\\0791 \\finalreportPit4Cushing.doc
EXPOSURE RATE MEASUREMENTS Exposure rate measurements ranged from 5 to 12 µR/h. Table 1 summarizes the exposure rate measurements. Background exposure rates ranged from 4 to 8 µR/h (ORISE 1996).
RADIONUCLIDE CONCENTRATIONS IN SOILS Concentrations of Th-228, Th-232, total thorium, U-235, U-238, and total uranium in soil samples collected from randomly selected locations and at the location of elevated direct gamma radiation identified during surface scans are summarized in Table 1. Th-228 concentrations ranged from 0.7 to 1.6 pCi/g and Th-232 concentrations ranged from 0.7 to 1.6 pCi/g, as determined by gamma spectroscopy. The calculated total thorium concentrations ranged from 1.4 to 3.3 pCi/g. U-235 concentrations ranged from -0.1 to 0.2 pCi/g and U-238 concentrations ranged from 0.6 to 3.3 pCi/g, as determined by gamma spectroscopy. Samples 1, 2, 4, 13, and 15 were selected for analysis by alpha spectroscopy to determine the ratio of U-234 to U-238 used to calculate the total uranium concentration. Table 2 provides the alpha spectroscopy data. Using the alpha spectroscopy data, the U-234 to U-238 ratio ranged from 0.90 to 1.14-the most conservative value of 1.14 was chosen for use in calculating the total uranium concentration. The calculated total uranium concentrations ranged from 1.44 to 5.48 pCi/g. Background uranium and thorium contributions were not accounted for in the activity calculations.
Elevated Ra-226, 4.1 +/- 0.5 pCi/g, was detected in Sample 13 which corresponded to the location of elevated direct gamma radiation previously discussed. Elevated levels of Ra-226 have been previously documented as being the result of past oil refinery operations which tended to concentrate Ra-226 within pipe scale (ORISE 1996). Ra-226 concentrations in all remaining soil samples ranged from 0.9 to 1.6 pCi/g.
COMPARISON OF RESULTS WITH GUIDELINES Results of the survey were compared to the applicable NRC guidelines (NRC 1981 ). These guidelines are summarized in Appendix C. The primary contaminants at KMC Cushing Refinery Site are enriched uranium, depleted uranium, and natural thorium. The applicable NRC option 1 guidelines for release for unrestricted use for these contaminants are as follows:
Kerr-McGee - August 15. 2001 5
y:essap\\project\\0791 \\finalreportPit4Cushing.doc
Enriched Uranium Soluble Insoluble Depleted Uranium Soluble Insoluble Natural Thorium (Th-232 + Th-228) with daughters present and in equilibrium 30 pCi/g 30 pCi/g 35 pCi/g 35 pCi/g 10 pCi/g Exposure rates were less than the guideline of 10 µR/h above background. No soil samples collected exceeded the NRC guideline values.
SUMMARY
At the request of the U.S. Nuclear Regulatory Commission, the Environmental Survey and Site Assessment Program of the Oak Ridge Institute for Science and Education conducted confirmatory survey activities of Pit 4, Survey Unit 3 at the Cushing Refinery Site in Cushing, Oklahoma. Confirmatory activities included independent surface scans and surface soil sampling during the period of June 25 through 27, 2001. ESSAP's confirmatory survey results indicated surf ace soil samples collected from Pit 4, Survey Unit 3 did not contain residual contamination in excess of the NRC guidelines for release for unrestricted use and therefore confirm KMC final status survey results.
Kerr-McGee-August 15. 2001 6
y:essap\\project\\0791 \\finalreportPit4Cushing.doc
FIGURES Kerr-McGee-August 15, 2001 y:essap\\project\\0791\\finalreportPit4Cusbing.doc
791-002 (x)
EDMOND*
N NOT TO SCALE KERR-McGEE CUSHING SITE FIGURE 1: Location of the Kerr-McGee Corporation Site, Cushing, Oklahoma Kerr.McGee-August 15, 2001 8
y:essap\\project\\0791 \\finalreportPit4Cushing.doc
791-004 (x) 0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
(',I I")
~
0 0
0 0
0 0
0 0
0 0
IJJ N 1002000 PIT4
...... ** 'AbM1N:......
BLDG.
1000000
- N 999000
- * * * * * * * * * * * ~ * *
- I * *
- t *.. I*..
- 1 * *.
N 998000 N
- N 997000 NOT TO SCALE
- M~~M.,__~*)E FENCE
- N 996000 FIGURE 2: Location of Pit 4 -
Cushing Refinery Site Kerr-McGee-August 15, 2001 9
y:essap\\project\\0791 \\finalreportPit4Cushing.doc
791-001 (5) 7..... *38..... :39...... 40.
1
- 2
- 5 * :*
16
..... :56...... :57..... :Ila....
- 15 7
9
,14
- 65.... :6.6..... fi7.....,6B.....-69..... 70..... *7.1....
_.,85..... *86...
MEASUREMENT /SAMPLING LOCATIONS
- # SURFACE SOIL
~
ELEVATED AREA
~
UNEXCAVATED GRID NUMBER
..,o. ---
N 0
FEET 100 I
I I
I I
O METERS 30 FIGURE 3: Cushing Refinery Site, Pit 4, Survey Unit 3 -
Sampling Locations Kerr-McGee-August 15, 2001 10 y:essap\\project\\0791 \\finalreportPit4Cushing.doc
TABLES Kerr-McGee:- August 15, 2001 y:essap\\project\\0791\\finalreportPit4Cushing.doc
Sample 8
1 2
3 4
5 6
7 8
9 10 11 12 13 14 15 16 TABLEl URANIUM AND THORIUM CONCENTRATIONS IN SOIL DETERMINED BY GAMMA SPECTROSCOPY PIT 4, SURVEY UNIT 3 CUSHING REFINERY SITE CUSIDNG, OKLAHOMA Exposure Radionuclide Concentration ( >Cilsd Rate at Total Thb 1 m (uR/h}
1.0 +/- O.ld 1.0 +/- 0.1 2.0 o.oe +/- 0.1 1.2 +/- 0.2 11 1.1 +/-0.1 1.1 +/- 0.2 2.2 0.1 +/- 0.1 1.2 +/- 0.6 12 1.3 +/- 0.2 1.3 +/- 0.2 2.6 0.1 +/- 0.1 0.8 +/-0.6 9
1.1 +/- 0.1 1.1 +/- 0.1 2.2 0.1 +/- 0.1 1.1 +/- 0.3 11 1.3 +/- 0.1 1.3 +/- 0.2 2.6 0.0 +/- 0.1 0.9+/-0.5 7
1.0 +/- 0.1 1.0 +/- 0.2 2.0 0.0 +/- 0.1 1.1 +/- 0.6 9
0.9 +/-0.1 1.0+/-0.1 1.9 0.0+/-0.1 0.9+/-0.3 7
1.2 +/-0.2 1.0 +/- 0.2 2.2 0.0 +/- 0.1 1.0 +/- 0.6 8
1.6 +/- 0.1 1.6 +/- 0.2 3.2
-0.1 +/- 0.1 0.9 +/-0.7 6
0.7 +/-0.1 0.7 +/-0.1 1.4 0.0 +/- 0.1 0.6 +/-0.3 6
1.2 +/- 0.1 1.1 +/-0.2 3.3 0.1 +/- 0.1 1.2 +/- 0.6 5
1.0 +/- 0.1 1.0 +/-0.2 2.0 0.0+/-0.1 0.7 +/-0.6 7
1.4 +/- 0.1 1.5 +/- 0.2 2.9 0.2 +/- 0.1 3.3 +/-0.9 6
1.3 +/- 0.1 1.3 +/-0.2 2.6 0.1 +/- 0.1 1.1 +/- 0.6 7
1.6 +/- 0.1 1.6 +/- 0.2 3.2 0.0+/-0.1 1.6 +/- 0.8 8
1.3 +/- 0.1 1.4 +/- 0.2 2.7 0.0 +/- 0.1 1.0 +/- 0.5 aRefer to Figure 3.
Total Uc 2.6 2.7 1.8 2.5 1.9 2.4 1.9 2.1 1.8 1.3 2.7 1.5 7.3 2.5 3.4 2.1 bTotal thorium concentration determined by summing the concentrations of Th-228 and Th-232. Uncertainties not propagated.
cTotal uranium concentration determined by multiplying the U-238 concentration by a factor of 1.14, based on the most conservative ratio of U-234 to U-238 as calculated using alpha spectroscopy data, then summing the measured U-235 and U-238 concentrations with the calculated U-234 concentration. Uncertainties not propagated.
dUncertainties are total propagated uncertainties at the 95% confidence level.
eZero values in this table are due to rounding.
Kerr-McGee - August 15, 2001 12 y:essap\\project\\0791 \\finalreportPit4Cushing.doc
Sample 8
1 2
4 13 15 aRefer to Figure 3.
TABLE2 URANIUM CONCENTRATIONS IN SOIL DETERMINED BY ALPHA SPECTROSCOPY PIT 4, SURVEY UNIT 3 U-234 0.86 +/- 0.1 lb 1.22 +/- 0.14 0.69 +/-0.09 2.76+/-0.27 0.77 +/-0.10 CUSIDNG REFINERY SITE CUSIDNG, OKLAHOMA Radionuclide Concentration (pCi/e;)
U-235 U-238 0.03 +/-0.02 0.81 +/- 0.10 0.05 +/-0.02 1.07 +/- 0.13 0.04+/-0.02 0.71 +/- 0.09 0.08 +/-0.03 2.64+/-0.26 0.04+/-0.02 0.86+/-0.10 bUncertainties are total propagated uncertainties at the 95% confidence level.
Total U 1.70 +/- 0.15 2.34 +/- 0.19 1.44 +/- 0.13 5.48 +/- 0.37 1.67 +/- 0.14 Kerr-McGee - August 15, 2001 13 y:essap\\project\\0791 \\finalreportPit4Cushing.doc
REFERENCES Kerr-McGee Corporation (KMC). Final Radiation Survey of Four Unaffected Areas of the Cushing Refinery Site. April 1995.
Oak Ridge Institute for Science and Education (ORISE). Confirmatory Survey for the Four Unaffected Areas of the Cushing Refinery Site, Kerr-McGee Corporation, Cushing, OK (Docket No. 70-3073). Oak Ridge, TN; May 1996.
Oak Ridge Institute for Science and Education. Survey Procedures Manual for the Environmental Survey and Site Assessment Program. Oak Ridge, TN; September 28, 2000.
Oak Ridge Institute for Science and Education. Quality Assurance Manual for the Environmental Survey and Site Assessment Program. Oak Ridge, TN; June 1, 2001a.
Oak Ridge Institute for Science and Education. Confirmatory Survey Plan for Pit 4, Survey Unit 3 of the Cushing Refinery Site, Cushing, Oklahoma. Oak Ridge, TN; June 22, 2001 b.
Oak Ridge Institute for Science and Education. Laboratory Procedures Manual for the Environmental Survey and Site Assessment Program. Oak Ridge, TN; May 1, 200 le.
U.S. Nuclear Regulatory Commission (NRC). Disposal or Onsite Storage of Thorium and Uranium Wastes from Past Operations. Washington, D.C.: Federal Register 46 (205): 52061-52063; October 1981.
U.S. Nuclear Regulatory Commission.
Draft NUREG/CR-5849. Manual for Conducting Radiological Surveys in Support of License Termination. Washington, D.C.; June 1992.
Kerr-McGee-August 15, 2001 14 y:essap\\project\\0791\\finalreponPit4Cushing.doc
Kerr-McGee-August 15, 2001 APPENDIXA MAJOR INSTRUMENTATION y:essap\\project\\0791 \\finalreportPit4Cushing.doc
APPENDIX A MAJOR INSTRUMENTATION The display of a specific product is not to be construed as an endorsement of the product or its manufacturer by the author or his employer.
DIRECT RADIATION MEASUREMENT Instruments Eberline Pulse Ratemeter ModelPRM-6 (Eberline, Santa Fe, NM)
Detectors Victoreen Nal Scintillation Detector Model 489-55 3.2 cm x 3.8 cm Crystal (Victoreen, Cleveland, Ohio)
Bicron Micro-Rem Meter (Bicron Corporation, Newburg, OH)
LABORATORY ANALYTICAL INSTRUMENTATION Alpha Spectrometry System Canberra Model 7401 VR (Canberra, Meriden, CT)
Used in conjunction with:
Ion Implanted Detectors and Multichannel Analyzer DEC ALPHA Workstation (Canberra, Meriden, CT)
High Purity Extended Range Intrinsic Detectors Tennelec Model No: ERVDS30-25195 (Canberra, Meriden, CT)
Used in conjunction with:
Lead Shield Model G-11 (Nuclear Lead, Oak Ridge, TN) and Multichannel Analyzer DEC ALPHA Workstation (Canberra, Meriden, CT)
Kerr-McGee-August 15, 2001 A-1 y:essap\\project\\0791 \\finalreportPit4Cushing.doc
High Purity Extended Range Intrinsic Detector Model No. GMX-45200-5 (EG&G ORTEC, OAK RIDGE, TN) used in conjuction with:
Lead Shield Model SPG-16-KS (Nuclear Data)
Multichannel Analyzer DEC ALPHA Workstation (Canberra, Meriden, CT)
High-Purity Germanium Detector Model GMX-23195-S, 23% Eff.
(EG&G ORTEC, Oak Ridge, TN)
Used in conjunction with:
Lead Shield Model G-16 (Gamma Products, Palos Hills, IL) and Multichannel Analyzer DEC ALPHA Workstation (Canberra, Meriden, CT)
Kerr-McGee-August 15, 2001 A-2 y:essap\\project\\0791 \\finalreportPit4Cushing.doc
APPENDIXB SURVEY AND ANALYTICAL PROCEDURES Kerr-McGee-August 15, 2001 y:essap\\project\\0791 \\finalreportPit4Cushing.doc
APPENDIXB SURVEY AND ANALYTICAL PROCEDURES PROJECT HEALTH AND SAFETY All survey and laboratory activities were conducted in accordance with ORISE health and safety and radiation protection procedures. ESSAP personnel also followed all safety requirements established by KMC for work at the Cushing Refinery Site.
CALIBRATION AND QUALITY ASSURANCE Calibration of all field and laboratory instrumentation was based on standards/sources, traceable to NIST, when such standards/sources were available. In cases where they were not available, standards of an industry-recognized organization were used.
Analytical and field survey activities were conducted in accordance with procedures from the following documents of the Environmental Survey and Site Assessment Program:
Survey Procedures Manual (September 2000)
Laboratory Procedures Manual (May 2001)
Quality Assurance Manual (June 2001)
The procedures contained in these manuals were developed to meet the requirements of DOE Order 414.lA and the U.S. Nuclear Regulatory Commission Qualify Assurance Manual for the Office of Nuclear Material Safefy and Safeguards and contain measures to assess processes during their performance.
Quality control procedures include:
Daily instrument background and check-source measurements to confirm that equipment operation is within acceptable statistical fluctuations.
Participation in MAPEP, NRIP, ITP and EML Laboratory Quality Assurance Programs.
Kerr-McGee-August 15, 2001 B-1 y:essap\\project\\0791 \\finalreportPit4Cushing.doc
Training and certification of all individuals performing procedures.
Periodic internal and external audits.
SURVEY PROCEDURES Surface Scans Surface scans were performed by passing the detectors slowly over the surface; the distance between the detector and the surface was maintained at a minimum-nominally about 1 cm.
Identification of elevated levels was based on increases in the audible signal from the indicating instrument. Combinations of detectors and instruments used for the scans were:
Gamma N al scintillation detector with ratemeter The scan minimum detectable concentrations (MDC) for the Nal scintillation detector for Th-232 in equilibrium with progeny in the decay series, depleted uranium, and enriched uranium were obtained directly from Table 6.4 of NUREG-15071* The scan survey was designed to be consistent with the a priori considerations used to develop the scan MDCs provided in Table 6.4.
The scan MDC for Th-232 was 2.8 pCi/g. The scan MDC for uranium varied with uranium enrichment, and ranged from 80.5 to 137 pCi/g, for depleted uranium (0.34% U-235) to 3%
enriched uranium, respectively. The Nal scintillation detector was chosen to provide the necessary sensitivity to detect thorium, but not uranium contamination below the guideline criteria.
Soil Sampling Approximately one kilogram of soil was collected at each sample location. Collected samples were placed in a plastic bag, sealed, and labeled in accordance with ESSAP survey procedures.
Minimum Detectable Concentrations With Typical Radiation Survey Instruments for Various Contaminants and Field Conditions. US Nuclear Regulatory Commission. Washington, DC; June 1998.
Kerr-McGee-August 15, 2001 B-2 y:essap\\project\\0791 \\finalreportPit4Cushing.doc
ANALYTICAL PROCEDURES Gamma Spectroscopy Samples of soil were dried, mixed, crushed, homogenized, and a portion sealed in a 0.5-liter Marinelli beaker. The quantity placed in the beaker was chosen to reproduce the calibrated counting geometry. Net material weights were determined and the samples counted using intrinsic germanium detectors coupled to a pulse height analyzer system. Background and Compton stripping, peak search, peak identification, and concentration calculations were performed using the computer capabilities inherent in the analyzer system. All photopeaks associated with the radionuclides of concern were reviewed for consistency of activity.
Photopeaks used for determining the activities of radionuclides of concern and the typical associated MDCs for a one-hour count time were:
Radionuclide Th-228 Th-232 U-235 U-238 Photopeak 0.583 MeV from Tl-208* or (0.239 MeV from Pb-212*)
0.911 MeV from Ac-228*
0.143 MeV (or 0.186 MeV) 0.063 MeV from Th-234*
(or 1.001 MeV from Pa-234m)*
- Secular equilibrium assumed.
MDC soil (pCi/g) 0.05 0.02 0.05 0.06 0.21 1.74 Spectra were also reviewed for other identifiable total absorption peaks.
Alpha Spectroscopy Soil samples were crushed, homogenized, ashed, and dissolved by potassium fluoride and pyrosulfate fusion and the elements of interest were precipitated with barium sulfate. Barium sulfate precipitate was redissolved and the specific elements of interest-isotopic uranium-were individually separated and re-precipitated with a cerium fluoride carrier. The precipitate was then analyzed using ion implanted detectors (Canberra), alpha spectrometer (Canberra), and a multichannel analyzer (Canberra). The typical uranium MDC of the procedure is 0.02 pCi/g.
Kerr-McGee - August 15. 2001 B-3 y:essap\\project\\0791 \\finalreportPit4Cusbing.doc
UNCERTAINTIES AND DETECTION LIMITS The uncertainties associated with the analytical data presented in the tables of this report represent the 95% confidence level for that data. These uncertainties were calculated based on both the gross sample count levels and the associated background count levels.
Detection limits, MDCs, were based on 3 plus 4.65 times the standard deviation of the background count [3+(4.65.JBKG) ]. When the activity was determined to be less than the MDC of the measurement procedure, the result was reported as less than MDC. Because of variations in background levels, measurement efficiencies, and contributions from other radionuclides in samples, the detection limits differ from sample to sample and instrument to instrument.
Kerr-McGee - August 15, 2001 B-4 y:essap\\project\\0791 \\finalreportPit4Cushing.doc
APPENDIXC GUIDELINES FOR RESIDUAL CONCENTRATIONS OF THORIUM AND URANIUM WASTES IN SOIL Kerr-McGee-August 15, 2001 y:essap\\project\\0791 \\finalreportPit4Cushing.doc
GUIDELINES FOR RESIDUAL CONCENTRATIONS OF THORIUM AND URANIUM WASTES IN SOIL On October 23, 1981, the Nuclear Regulatory Commission published in the Federal Register a notice of Branch Technical Position on "Disposal or Onsite Storage of Thorium and Uranium Wastes from Past Operations." This document establishes guidelines for concentrations of uranium and thorium in soil, that will limit maximum radiation received by the public under various conditions of future land usage. These concentrations are as follows:
Material Natural Thorium (Th-232 + Th-228) with daughters present and in equilibrium Natural Uranium (U-238 + U-234) with daughters present and in equilibrium Depleted Uranium:
Soluble Insoluble Enriched Uranium:
Soluble Insoluble Maximum Concentrations (pCi/g) for various options 10 50 500 10 40 200 35 100 1,000 35 300 3,000 30 100 1,000 30 250 2,500 aBased on EPA cleanup standards which limit radiation to 1 mrad/yr to lung and 3 mrad/yr to bone from ingestion and inhalation and 10 µR/h above background from direct external exposure.
bBased on limiting individual dose to 170 mrem/yr.
cBased on limiting equivalent exposure to 0.02 working level or less.
dBased on limiting individual dose to 500 mrem/yr and in case of natural uranium, limiting exposure to 0.02 working level or less.
Kerr-McGee-August 15, 2001 C-1 y:essap\\project\\0791 \\finalreportPit4Cushing.doc