OAK RIDGE INSTITUTE FOR SCIENCE AND EDUCATION June 30, 2006 Ms. Beth Schlapper U.S. Nuclear Regulatory Conunission Region IV: DNMS: NMLB Suite 400 611 Ryan Plaza Drive Arlington, TX 76011
SUBJECT:
ANALYTICAL RESULTS FOR SIX WATER SAMPLES COLLECTED MAY 23, 2006 FROM TRONOX-CIMARRON CORPORATION, CRESCENT, OKLAHOMA (INSPECTION REPORT #070-00925/06-001) [RFTA NO. 06-001]
Dear Ms. Schlapper:
The Oak Ridge Institute for Science and Education (ORISE) received six water samples for analysis from Tronox-Cima.rron Corporation, Crescent, Oklahoma on May 25, 2006. The samples were analyzed for gross alpha, gross beta, and uranium alpha isotopic. The gross alpha and gross beta data are presented in Table 1. The uranium isotopic data are presented in Table
- 2. The pertinent procedure references are provided in the specific tables.
ORISE's Quality Control (QC) requirements were met for these analyses. The QC files a.re available for your review upon request.
My contact information is listed below. You may also contact Wade Ivey at 865.576.9184 with any questions or comments.
Sincerely, QJL -cL Dale Condra, tfanager Laboratory RDC/WPI:db Enclosures c:
B. Watson, NMSS/DWMEP/DD/SP 7E18 E. K.nox-Davin, NRC/NMSS/T\\X!FN T8A23 File 1705 Distribution approval and concurrence:
Technical :'.vlanagement Team Member Quality Manager Voice: 865.241.3242 Fax: 865.241.3248 E. Abelquist, ORISE S. Kirk, ORISE Lutials E-mail: CondraD@orau.gov
[
TABLE1 CONCENTRATIONS OF GROSS ALPHA AND GROSS BETA BY GAS-LOW PROPORTIONAL COUNTING AP1, REVISION 14; CP3, REVISION 2 TRONOX-CIMARRON CORPORATION CRESCENT, OKLAHOMA ORISE Sample NRC Region IV Concentrations, TPUs, and MDCsa (pCi/L)
ID Sample ID Gross Alpha Gross Beta 1705W0001 NRC 6-01 45.9
+/- 5.6b (2.8) 20.7
+/-
3.2 (3.2) 1705W0002 NRC 6-02 3.8
+/-
1.7 (2.3) 3.2
+/-
2.0 (3.1) 1705W0003 NRC 6-03 51.0
+/-
6.7 (3.7) 34.6
+/-
4.7 (4.1) 1705W0004 NRC 6-04 58
+/-
12 (11) 529
+/-
61 (13) 1705WOOOS NRC 6-05 1520 +/- 110 (10) 730
+/-
70 (10) 1705W0006 NRC 6-06 3850 +/- 270 (10) 1520
+/-
140 (10) aMDCs are in parentheses.
bUncertainties represent the 95% confidence level, based on total propagated uncertainties.
Tronon-Comarron Corporation projects/1705/Tables/2006-06-30 Data Tables
TABLE2 CONCENTRATIONS OF SELECTED ALPHA EMITTING RADIONUCLIDES IN WATER SAMPLES BY ALPHA SPECTROSCOPY AP11, REVISION 3; CP2, REVISION 12 TRONOX-CIMARRON CORPORATION CRESCENT, OKLAHOMA ORISE Sample NRC Region IV Radionuclide Concentrations a (pCi/L)
ID Sample ID U-234 U-235 U-238 1705W0001 NRC 6-01 69.2 +/- 5.2c (0.1) 2.91 +/- 0.53 (0.16) 11.1 +/- 1.1 1705W0002 NRC 6-02 12.2 +/- 1.3 (0.1) 0.62 +/- 0.26 (0.22) 2.39 +/- 0.46 1705W0003 NRC 6-03 62.5 +/- 5.0 (0.4) 3.38 +/- 0.61 (0.25) 17.2 +/-
1.7 1705W0004 NRC 6-04 30.9 +/- 2.7 (0.2) 1.58 +/- 0.39 (0.06) 11.2 +/- 1.2 1705W0005 NRC 6-05 1,108 +/- 91 (10) 61
+/-
11 (4) 766 +/-
66 1705W0006 NRC 6-06 2,750 +/- 200 (O)d 154 +/-
19 (3) 1,650 +/- 120
'The MDCs are in parentheses.
"Total U is the sum of U-234 + U-235 + U-238.
cUncertainties represent the 95% confidence leve~ based on total propagated uncertainties.
dzero values are due to rounding.
Total U b (0.1) 83.2 +/- 5.4 (0.14) 15.2 +/- 1.4 (0.4) 83.1 +/- 5.3 (0.2) 43.6 +/- 3.0 (7) 1,900 +/- 110 (0) 4,600 +/- 230