March 6, 2013 Mr. Gerald Schlapper
-* -
--,--, ,.
U.S. Nuclear Regulatory Commission, Region IV 1600 East Lamar Boulevard Arlington, TX 76011 ORISE CONTRACT NO. DE-AC05-060R23100 ORAU OAK RIDGE ASSOCIATED UNIVERSITIES
SUBJECT:
LETTER REPORT FOR ANALYTICAL RESULTS FOR SEVEN SOIL SAMPLES ASSOCIATED WITH THE CIMARRON CORPORATION IN CIMARRON, OKLAHOMA (RFTA NO.12-001)
DCN: 5199-LR-02-0
Dear Mr. Schlapper:
Oak Ridge Associated Universities (ORAU), under the Oak Ridge Institute for Science and Education (ORlSE) contract, received seven soil samples on February 19, 2013 from the Cimarron Corporation in Cimarron, Oklahoma. The samples were analyzed for uranium-235, uranium-238, and total uranium by gamma spectrometry as directed from email communication on February 20, 2013. The cha.in of custody that accompanied the samples were from the Environmental Properties Management laboratory. There was no NRC Form 303 or NRC Form 303A supplied with the samples. The sample identification numbers a.re presented in Table 1 and the uranium by gamma spectrometry data are presented in Table 2. The pertinent procedure reference is included with the data table.
ORAU's Quality Control (QC) requirements were met for these analyses. The QC files are available for your review upon request.
My contact information is listed below. You may also contact Forrest Smith at 865.574.9802 with any questions or comments.
Sincerely, tl::r Laboratory WPI:WFS:km Enclosures c:
T. Carter, NRC/FSME/D\\"VMEP T-8F5 S. Nesmith, NRC/FSME/PBPA/T\\'(ff'N 8A23 Electronic:
S. Roberts, ORAU T. Vitkus, ORAU Telephone: 865.576.9184 Fax: 865.241.3248 File 5199 E-mail: wade.ivey@orau.org P.O. Box 117 I Oak Ridge, TN 37831 I www.orau.org
--==- -
--::-- -.::: ----=--
I I I
~
I
ORISE Sample ID 5199S0001 5199S0002 5199S0003 5199S0004 5199S0005 5199S0006 5199S0007 Cimarron TABLE!
SAMPLE IDENTIFICATIONS AND COLLECTION DATA CIMARRON CORPORATION CIMARRON, OKLAHOMA NRC Region IV Collection Sample ID Date CS-BAl-04-9'-10'-NRC 9/25/2012 CS-BA 1-01-5'-6' -NRC 9/26/2012 CS-BAl-01-21 '-22'-NRC 9/26/2012 GE-BAl-01-9'-10'-NRC 9/26/2012 GE-BAl-01-21 '-22'-NRC
. 9/26/2012 CS-BAl-02-13'-14'-NRC 9/26/2012 CS-BAl-03-2'-3'-NRC 9/27/2012 Collection Time 2:32PM 7:53AM 8:50AM 11:30AM 12:00 PM 1:24 PM 3:58PM 5199-LR-02-0
Cimarron TABLE2 CONCENTRATIONS OF SELECTED GAMMA EMITTERS IN SOIL SAMPLES BY GAMMA SPECTROMETRY CP1, REVISION 17 CIMARRON CORPORATION CIMARRON, OKLAHOMA ORAU/ORISE NRC Region IV Radionuclide Concentrations, TPUs\\ and MDCsb (pCi/g)
Sample ID Sample ID U-238 by Th-234 5199S0001 CS-BAl-04-9'-10'-NRC 1.29
+/- 0.26, 0.53 5199S0002 CS-BAl-01-5'-6'-NRC 1.05
+/- 0.29, 0.62 5199S0003 CS-BAl-01-21 '-22'-NRC 1.35
+/- 0.30, 0.61 5199S0004 GE-BAt-01-9'-10'-NRC 3.87
+/- 0.47, 0.78 5199S0005 GE-BAl-01-21 '-22'-NRC 2.62
+/- 0.38, 0.67 5199S0006 CS-BAl-02-13'-14'-NRC 5.14
+/- 0.67, 1.10 5199S0007 CS-BAl-03-2'-3'-NRC 0.71
+/- 0.32, 0.73 "Uncertainties represent the 95% confidence level, based on total propagated uncertainties.
"The MDCs are after the comma.
"Total uranium calculated by the formula: (2
0.14 0.07 0.12 0.35 0.16 0.43 0.07 U-235 Total lf
+/- 0.06 ' 0.13 2.72 +/- 0.52
+/- 0.06 ' 0.15 2.17 +/- 0.58
+/- 0.06 ' 0.13 2.82 +/- 0.60
+/- 0.07-, 0.14 8.09 +/- 0.94
+/- 0.07 ' 0.17 5.40 +/- 0.76
+/- 0.12 ' 0.24 10.7 +/-
1.3