g C>RISE OAK RIDGE INSTITUTE FOR SCIENCE AND EDUCATION July 29, 2003 Mr. Emilio M. Garcia U.S. Nuclear Regulatory Commission Region IV Harris Tower, Suite 400 611 Ryan Plaza Drive Arlington, TX 76011-8064

SUBJECT:

REPORT FOR ANALYSIS OF THE WATER SAMPLES FROM KERR-McGEE CIMARRON FACILITY, CIMARRON, OKLAHOMA (INSPECTION REPORT NO. 07000925/2003001)

[RFTA NO. 03-001]

Dear Mr. Garcia:

The Environmental Survey and Site Assessment Program (ESSAP) of the Oak Ridge Institute for Science and Education (ORISE) received 24 water samples that were collected on June 24 and June 25, 2003 at the Kerr-McGee Cimarron facility in Cimarron, Oklahoma. All water samples were analyzed for gross alpha and beta and isotopic uranium. Tc-99 analysis was performed on the 18 designated water samples.

The water results for gross alpha and beta (Procedures APl, Revision13 and CP3 Revision!), Tc-99 (Procedure APS, Revision 14 and Procedure CP4, Revision 2), and isotopic uranium (Procedure APll, Revision 1 and Procedure CP2, Revision 11) are presented in Tables 1, 2, and 3 respectively.

ESSAP's Quality Control (QC) requirements were met for these analyses. The QC files are available for your review upon request.

P. 0. BOX 117, OAK RIDGE, TENNESSEE 37831-0117 Operated by Oak Ridge Associated Universities for the U.S. Deportment of Energy

Mr. Emilio July 29, 2003 Please contact me at (865) 241-3242 or Wade Ivey at (865) 576-9184 should you have any questions.

Sincerely, Dale Condra Laboratory Manager Environmental Survey and Site Assessment Program RDC:WPI:ar Attachments cc:

T. McLaughlin, NRC/NMSS/fWFN 7F27 E. Knox-Davin, NRC/NMSS/fWFN 8A23 J. Peckenpaugh, NRC/NMSS/fWFN 7J8 K. Kalman, NRC/NMSS/fWFN 7F27 File/862 Initials E. Abelquist, ORISE/ESSAP T. Vitkus, ORISE/ESSAP G. Purdy, NRC/NMSS/fWFN 7F27 R. Munoz, Region IV Date

ORISE TABLE 1 CONCENTRATIONS OF GROSS ALPHA AND BETA IN WATER SAMPLES BY LOW BACKGROUND ALPHA AND BETA COUNTING APl, REVISION 13; CP3, REVISION 1 CIMARRON (KERR-McGEE)

CIMARRON,OKLAHOMA Concentrations ESSAP Sample NRC Region IV (pCi/L)

ID Sample ID Gross Alpha 8

Gross Betab 862W001 N-T-60-1841 35.1 +/- 7.9c 18.1 +/- 4.2 862W002 N-T-53-1842 12.8 +/-4.6 21.4+/-3.7 862W003 N-T-51-1843 12.3 +/- 3.4 12.8 +/- 2.9 862W004 N-T-58-1844 25.9+/-3.6 79.2 +/- 7.3 862W005 N-T-57-1845 20.7 +/-3.5 345 +/- 31 862W006 N-T-54-1846 21.8 +/- 5.5 820+/-81 862W007 N-T-62-1864 31.3 +/- 6.6 324+/-34 862W008 N-1208-1847 151 +/- 17 1740 +/- 170 862W009 N-T-55-1848 27.8 +/-6.0 351 +/- 37 862W010 N-T-56-1849 11.5 +/-2.0 118 +/- 11 862W011 N-1336A-1850 74.1 +/-6.7 554+/-48 862W012 N-1312-1851 125 +/- 12 1080+/-99 862W013 N-1315R-1852 1510+/-90 455 +/-40 862W014 N-TMW13-1853 2070 +/- 140 526 +/-49 862W015 N-1352-1854 322 +/- 19 146 +/- 13 862W016 N-1206-1855 108.1 +/- 7.8 33.1 +/- 3.4 862W017 N-1350-1856 62.8+/-5.4 46.4+/-4.5 862W018 N-1348-1857 104.9 +/-6.9 28.5 +/- 2.9 862W019 N-1349-1858 44.2 +/-4.5 10.7 +/- 1.8 862W020 N-1331-1859 89.0 +/- 7.0 20.8 +/- 2.5 862W021 N-1326-1860 7.5 +/- 1.5 16.7 +/- 2.0 862W022 N-1319Cl-1861 346+/-34 79+/- 10 862W023 N-1319Bl-1862 163 +/- 13 49.2+/-5.4 862W024 N-1319Al-1863 53.0+/-4.9 17.6 +/- 2.1

--rhe average MDC for gross alpha for a 200 minute count using O.OS L to 0.25 L samples is 3.4 pCi/L

~e average MDC for gross beta for a 200 minute count using O.OS L to 0.25 L samples is 3.6 pCi/L "Uncenainties represent the 95% confidence level, based on total propagated uncertainties.

Cimarron (Kerr-McGee) (862) - July 29, 2003 y:essaplablsitedata/862_C"unarron_ 7 _03_Data_ Tables.xls

ORISETABLE2 CONCENTRATIONS OF Tc-99 IN WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS APS, REVISION 14; CP4, REVISION 2 CIMARRON (KERR-McGEE)

CIMARRON,OKLAHOMA NRC Region IV Tc-99 8

ESSAP Sample ID Concentrations Sample ID (pCi/L) 862W00I N-T-60-1841 14.4 +/- 9.4 b 862W002 N-T-53-1842 20.6 +/-9.7 862W003 N-T-51-1843 9.4 +/-9.2 862W004 N-T-58-1844 125 +/- 19 862W005 N-T-57-1845 615 +/- 75 862W006 N-T-54-1846 1400 +/- 170 862W007 N-T-62-1864 659 +/- 80 862W008 N-1208-1847 1790 +/-210 862W009 N-T-55-1848 717 +/- 87 862WOI0 N-T-56-1849 212+/-28 862W011 N-1336A-1850 950 +/- 120 862W012 N-1312-1851 1950 +/- 230 862W013 N-1315R-185~

18.6 +/-9.5 862W014 N-TMW13-1853 13.0 +/- 9.2 862W015 N-1352-1854 26.5 +/-9.9 862W016 N-1206-1855 12.0 +/- 9.1 862W017 N-1350-1856 52+/- 12 862W018 N-1348-1857 6.5 +/- 8.9

'The average MDC f9r Tc-99 for a 60 minute count using a 0.1 L sample is 15 pCi/L.

htrncertaioties represent the 95% confidence level. based on total propagated uncertainties.

Cimarron (Kerr-McGee) (862) - July 29, 2003 y:essapJablsitedata/862_Cimarron_7 _03_Data_ Tablcs.xJs

ORISE TABLE 3 CONCENTRATIONS OF URANIUM ISOTOPES IN WATER SAMPLES BY ALPHA SPECTROSCOPY APll, REVISION 1; CP2, REVISION 11 CIMARRON (KERR-McGEE)

CIMARRON,OKLAHOMA ESSAP Sample NRC Region IV Radionuclide Concentrations 8 (pCi/L)

ID Sample ID U-234 U-23S U-238 862W001 N-T-60-1841 12.9 +/- 1.4c 0.52 +/-0.24 6.98 +/- 0.90 862W002 N-T-53-1842 9.1 +/- 1.0 0.28 +/-0.18 4.54+/-0.67 862W003 N-T-51-1843 14.3 +/- 1.4 0.72+/-0.32 8.23 +/-0.97 862W004 N-T-58-1844 19.4 +/- 1.7 1.01 +/- 0.29 5.91 +/-0.74 862W005 N-T-57-1845 14.4 +/- 1.5 0.75 +/-0.27 4.48 +/- 0.66 862W006 N-T-54-1846 3.93 +/-0.67 0.12 +/-0.17 2.35 +/-0.48 862W007 N-T-62-1864 3.90 +/-0.61 0.14 +/-0.11 2.49 +/-0.47 862W008 N-1208-1847 2.35 +/-0.48 0.13 +/- 0.14 0.55 +/-0.22 862W009 N-T-55-1848 2.78 +/-0.61 0.10 +/- 0.15 2.17 +/-0.48 862W010 N-T-56-1849 1.85 +/-0.50 0.02 +/-0.19 1.20 +/- 0.36 862W011 N-1336A-1850 18.1 +/- 1.9 0.72 +/-0.28 6.20+/-0.88 862W012 N-1312-1851 23.9 +/- 2.2 1.03 +/-0.33 8.6 +/- 1.1 862W013 N-1315R-1852 1,250 +/- 94 72.0 +/-6.0 803 +/-60 862W014 N-TMW13-1853 1,327 +/- 98 78.2 +/- 6.4 820 +/-60 862W015 N-1352-1854 199 +/- 16 11.8 +/- 1.5 250 +/-20 862W016 N-1206-1855 93.3 +/- 7.3 4.59 +/-0.74 24.4+/-2.2 862W017 N-1350-1856 45.5 +/- 3.8 2.58 +/-0.54 10.5 +/- 1.2 862W018 N-1348-1857 92.5 +/- 6.9 3.95 +/- 0.65 28.8 +/-2.5 862W019 N-1349-1858 57.8 +/-4.6 2.84 +/- 0.55 8.9 +/- 1.0 862W020 N-1331-1859 79.1 +/- 6.4 4.13 +/- 0.76 15.4 +/- 1.6 862W021 N-1326-1860 3.69 +/-0.60 0.14 +/-0.11 2.22 +/-0.44 862W022 N-1319Cl-1861 190 +/- 14 8.9 +/- 1.1 29.3 +/-2.6 862W023 N-1319Bl-1862 161 +/- 12 7.8 +/- 1.0 23.6 +/- 2.2 862W024 N-1319Al-1863 38.8 +/- 3.4 1.80 +/- 0.46 6.49 +/-0.88

~e average MDC for individual uranium isotopes for a sixteen hour count using 0.1 L of sample is 0.3 pCi/L.

'>u Total is the sum of u.234 + u.235 + U*238.

'Uncertainties represent the 95% confidence level, based on total propagated uncertainties.

UTotalb 20.4 +/- 1.7 13.9 +/- 1.3 23.3 +/- 1.8 26.3 +/- 1.9 19.6 +/- 1.6 6.40 +/-0.84 6.52 +/-0.78 3.03 +/- 0.55 5.05 +/-0.79 3.07 +/-0.65 25.0 +/- 2.1 33.5 +/- 2.5 2,130 +/- 110 2,230 +/- 110 461 +/- 25 122.3 +/- 7.7 58.6 +/-4.1 125.3 +/- 7.4 69.6+/-4.7 98.6 +/- 6.6 6.06 +/-0.76 228 +/- 15 192 +/- 12 47.1 +/- 3.5 Cimarron (Kerr*McGee) (862)

  • July 29, 2003 y:essaplab/sitedata/862_Cimarron_ 7 _03_Data_ Tables.xis