ML19106A233

From kanterella
Jump to navigation Jump to search
5199 - Kerr Mcgee Cimarron Nine Water Samples - Aug 2012
ML19106A233
Person / Time
Site: 07000925
Issue date: 08/29/2012
From: Ivey W
Oak Ridge Associated Universities
To: Schlapper G
NRC Region 4
Shared Package
ML19106A222 List:
References
Download: ML19106A233 (5)


Text

August 29, 2012 Nfr. Gerald Schlapper U.S. Nuclear Regulatory Commission, Region IV 1600 East Lamar Boulevard Arlington, TX 76011 ORISE CONTRACT NO. DE-AC0S-06OR23100 ORA.U OAK RIDGE ASSOCIATED UNIVERSITIES

SUBJECT:

LETTER REPORT FOR ANALYTICAL RESULTS FOR NINE WATER SAMPLES ASSOCIATED WITH THE CIMARRON CORPORATION IN CIMARRON, OKLAHOMA

[INSPECTION REPORT NO. 07000925/2012002; NRC CONTROL NO. UIL-12-1) (RFTA NO.12-001)

DCN: 5199-LR-01-0

Dear Nfr. Schlapper:

Oak Ridge Associated l.;niversities (ORAU), under the Oak Ridge Institute for Science and Education (ORISE) contract, received nine water samples on August 2, 2012 from the Cimarron Corporation in Cimarron, Oklahoma. The samples were analyzed for gross alpha and beta activity, isotopic uranium, and technetium-99 (f c-99) according to the chain of custody form supplied with the samples. The sample identification numbers are presented in Table 1 and the gross alpha and beta, isotopic uranium, and Tc-99 data are presented in Tables 2 through 4, respectively. The pertinent procedure references are included with the data tables.

The requested minimum detectable activity (NIDA) was not met for samples T-77 and 1201. The amount of dissolved material in these two samples limited the amount of sample that could be analyzed, thus increasing the tvIDA. Sample 1346 was analyzed for gross alpha and beta and Tc-99 and the Tc-99 activity is about twice the gross beta activity. This could possibly be due to the volatilization ofTc-99 prior to the gross beta analysis as the sample is heated over a 500 °C flame prior to counting, thus reducing the gross beta measurement.

ORAU's Quality Control (QC) requirements were met for these analyses. The QC files are available for your review upon request.

My contact information is listed below. You may also contact Forrest Smith at 865.574.9802 with any questions or comments.

Sincerely,

(,j.1&/

Wade Ivey, Mana{er Laboratory

\\VPI:WFS:km Enclosures c:

T. Carter, NR.C/FSME/DW1vIEP T-8F5 S. Nesmith, NRC/FSME/PBPA/T\\VFN 8A23 Electronic:

S. Roberts, OR.AU T. Vitkus, OR.AU Technical Review Telephone: 865.576.9184 Fax: 865.241.3248 File 5199 E-mail: wade.ivey@orau.org P.O. Box 117 I Oak Ridge, TN 37831 I www.orise.orau.gov

ORISE Sample ID 5199W0001 5199W0002 5199W0003 5199W0004 5199WOOOS 5199W0006 5199W0007 5199W0008 5199W0009 Cimarron TABLE1 SAMPLE IDENTIFICATIONS AND COLLECTION DATA CIMARRON CORPORATION CIMARRON, OKLAHOMA NRC Region IV Collection Sample ID Date TMW-13 7/31/12 1312 8/1/12 1346 8/1/12 1352 7/31/12 T-77 7/31/12 1201 8/1/12 1313 8/1/2012 1336A 7/31/2012 Seep 1208 8/1/2012 Collection Time 9:08AM 7:05AM 8:40AM 1:57 PM 1:22 PM 9:45AM 7:15 AM 10:32 AM 7:38AM 5199-LR-01-0

Cimarron TABLE2 CONCENTRATIONS OF GROSS ALPHA AND BETA RADIONUCLIDES IN WATER SAMPLES BY GROSS ALPHA AND BETA FOR VARIOUS MATRICES APl, REVISION 18; CP3, REVISION 3 CIMARRON CORPORATION CIMARRON, OKLAHOMA ORISE NRC Region IV Radionuclide Concentrations, TPU s a, and Sample ID Sample ID MDCsb (pCi/L)

Gross Alpha 5199W0001 TMW-13 1104

+/- 26 4

260 5199W0002 1312 34.9

+/- 5.8 4.7 425 5199W0003 1346 9.6

+/- 2.1 1.7 594.1 5199W0004 1352 80.1

+/- 4.9 1.8 42.1 5199WOOOS T-77 146

+/- 17 12 39.0 5199W0006 1201

-3

+/- 19 ' 36 26 3Uncertainties represent the 95% confidence level, based on total propagated uncertainties.

bThe MDCs appear after the commas.

Gross Beta

+/- 10

+/-

11

+/- 7.7,

+/- 2.5

+/- 8.8

+/- 22 5

5 1.8 2.1 12.2 37 5199-LR-01-0

TABLE3 CONCENTRATIONS OF URANIUM ISOTOPES IN WATER SAMPLES BY ALPHA SPECTROSCOPY AP11, REVISION 6; CP2, REVISION 16 CIMARRON CORPORATION CIMARRON, OKLAHOMA ORISE NRC Region IV Radionuclide Concentrations, TPUs\\ and MDCsh(pCi/L)

Sample ID Sample ID U-234 5199W0001 TMW-13 707 +/-

93 od 36.3 5199W0002 1312 23.8 +/-

3.4 0.4 1.11 5199W0003 1346 1.20 +/- 0.34

, 0.26 0.04 5199W0004 1352 50.1 +/-

6.8 0.3 2.30 5199WOOOS T-77 202

+/-

26 1

10.0 5199W0006 1201 0.66 +/- 0.25

, 0.28 0.00

'Uncertainties represent the 95% confidence level, based on total propagated uncertainties.

"The MDCs appear after the commas.

'Total U is calculated by U-234 + U-235 + U-238.

dzero values arc due to rounding.

Cimarron U-235 U-238

+/- 5.9

, 0.9 383 +/-

51 1

+/- 0.37, 0.35 7.7

+/- 1.3 0.3

+/- 0.09 ' 0.21 0.92 +/- 0.28

' 0.05

+/- 0.56 ' 0.29 36.3 +/- 5.0 0.2

+/- 1.6 ' 0.1 32.7 +/-

4.5 0.4

+ 0.11 0.34 0.40 +/- 0.18

, 0.06 Total Uc 1,100

+/- 110 32.7

+/- 3.6 2.16

+ 0.45 88.7

+/- 8.4 244.0

+/- 27.0 1.06

+/- 0.33 5199-LR-01-0

Cimarron TABLE4 CONCENTRATION OF TECHNETIUM-99 IN WATER SAMPLES BY LIQUID SCINTILLATION COUNTING AP5, REVISION 19; CP4, REVISION 4 CIMARRON CORPORATION CIMARRON, OKLAHOMA Radionuclide ORISE NRC Region IV Concentrations, TPU sa, Sample ID Sample ID and MDCsb (pCi/L) 5199W0003 1346 1,148 +/-

58

' 15 5199W0007 1313 864

+/-

45

' 15 5199W0008 1336A 1,102 +/-

56 15 5199W0009 Seep 1208 862

+/-

45

' 15 aUncertainties represent the 95% confidence level, based on total propagated uncertainties.

bThe MDCs appear after the commas.

5199-LR-01-0