ML18220A874

From kanterella
Jump to navigation Jump to search
Enclosunuscale CIRLT-RAI 9474
ML18220A874
Person / Time
Site: NuScale
Issue date: 07/25/2018
From: Harris S
NuScale
To:
Office of New Reactors
Shared Package
ML18220A872 List:
References
LO-0718-61173 PM-0718-61172, Rev. 0
Download: ML18220A874 (10)


Text

Enclosure:

"NuScale CIRLT-RAI 9474," PM-0718-61172 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com L0-0718-61173

PM-0718-61172 Revision: O NuScale Nonproprietary NuScale CILRT-RAI 9474 July 25th, 2018 Scott Harris Gary McGee Ed Heald Corrie Nichol Copyright 2018 by NuScale Power, LLC.

    • NUSCALE

.;:*POWER=

Template#: 0000-21727-F01 R3

Agenda

  • Recap of proposed RAI response

- Preservice Design Pressure Leakage Test

- CNV flange analysis

- ITAAC

- Response summary

  • Refueling Overview (video)
  • Closed Session (proprietary)

- Screenshots of flange analysis model

- Additional slides for refueling discussion if needed 2

PM-0718-61172 Revision: 0 Copyright 2018 by NuScale Power, LLC.

    • NUSCALE

.tpow1=R=

Template#: 0000-21727-F01 R3

CILRT

- Type A (vessel test at accident pressure - NuScale seeks exemption)

- Type B (containment penetrations)

- Type C (containment isolation valves)

  • In lieu of a Type A test, NuScale is proposing a preservice design pressure leakage test

Purpose:

Verify design of flange seals through leak test at design pressure 3

PM-0718-61172 Revision: O Copyright 2018 by NuScale Power, LLC.

  • NUSCALE J.. POWE
    • :R' Template#: 0000-21727-F01 R3

Preservice Design Pressure Leakage Test

  • Test Characteristics

- CNV assembled with all flanges in place

- Take place in factory or onsite (must be out of RXB pool)

- Test will use final design flanges, bolting material (with design preload), and design seals

- Test will be performed with water as the pressure medium (similar to hydrotest)

- Test occurs at containment design pressure 4

PM-0718-61172 Revision: 0 Copyright 2018 by NuScale Power, LLC.

    • NUSCALE

,;:*POWER' Template#: 0000-21727-F01 R3

Preservice Design Pressure Leakage Test

  • Acceptance Criteria

- Design pressure must be held for a minimum of 10 minutes prior to start of inspection

- Pressure will be maintained at or above design pressure for the time needed to visually inspect each vessel flange for leakage past outer flange seal

- Successful test is no visible leakage at bolted connections

- Similar to code requirements for a hydrotest

  • Subsequent Modules

- Test may be modified so that upper and lower can be tested separately 5

PM-0718-61172 Revision: O Copyright 2018 by NuScale Power, LLC.

';*NUSCALE

.:*.. POWER' Template#: 0000-21727-F01 R3

,~--


- - - - - - ~

CNV Bolting Analysis

  • Updating the Containment Vessel Flange Bolting Calculation for new scope:
  • Add analysis to demonstrate that inner a-ring seal contact is maintained for all CNV bolted flanges when internal containment is at design pressure when considering accident thermal transient conditions
  • Add analysis to demonstrate that lifting and moving the module does not stress CNV bolted flanges in a manner that contributes to flange distortion or seal positioning that would create leakage
  • Add assessment to show results of testing under ambient temperature conditions 6

PM-0718-61172 Revision: O Copyright 2018 by NuScale Power, LLC.

      • NUSCALE

.:*.. POWER' Template#: 0000-21727-F01 R3

CNV Bolting Analysis

  • Models of the bottom, middle, and top of the CNV, similar to the CNV ultimate pressure integrity calc, are used. Each type of bolted flange connection is modeled
  • Stud, nuts, washers and threaded inserts are included in the mode with contact defined between the nuts-washers, washers-flange, and cover-flange
  • All bolted connection preloads are calculated with margin over minimum preload need to maintain a tight joint
  • Thermal transient analyzed to obtain temperature distribution through CNV for inadvertent RRV opening and eves injection line break transients
  • The design pressure will be applied with temperature occurring at the time of peak accident pressure.

7 PM-0718-61172 Revision: 0 Copyright 2018 by NuScale Power, LLC.

    • NUSCALE

,;:*POWER' Template#: 0000-21727-F01 R3

I~

ITAAC 02.01.07

  • Design Commitment

- The CNV serves as an essentially leak-tight barrier against the uncontrolled release of radioactivity to the environment.

  • Inspections, Tests, Analyses

- A leakage test will be performed of the pressure containing or leakage-limiting boundaries, and CIVs.

  • Acceptance Criteria

- The leakage rate for local leak rate tests (Type B and Type C) for pressure containing or leakage-limiting boundaries and CIVs meets the requirements of 10 CFR Part 50, Appendix J.

  • This ITAAC will be modified to include Acceptance Criteria for the preservice leak test at design pressure, with clarifying details added to Tier 2, Section 14.3.

8 PM-0718-61172 Revision: 0 Copyright 2018 by NuScale Power, LLC.

    • NUSCALE

,;:*POWER' Template#: 0000-21727-F01 R3

Summary of RAI 9474 Response

  • Update to Technical Report to update leakage assessment program (TR-1116-51962)
  • Update Type A Test Exemption
  • Update Table 14.3-1 to match ITAAC
  • Submit responses to RAI 9474, Questions 06.02.06-22 through 06.02.06-26 9

PM-0718-61172 Revision: O Copyright 2018 by NuScale Power, LLC.

';* NUSCALE

.:-.. POWER' Template#: 0000-21727-F01 R3