L0-0419-64807 April 2, 2019 Docket No.52-048 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738
SUBJECT:
NuScale Power, LLC Submittal of Presentation Materials Entitled "ACRS Full Committee Presentation: NuScale Chapter 9, Auxiliary Systems," PM-0319-64807, Revision 0 The purpose of this submittal is to provide presentation materials to the NRC for use during the upcoming Advisory Committee on Reactor Safeguards (ACRS) NuScale Full Committee meeting on April 4, 2019. The materials support NuScale's presentation of Chapter 9, "Auxiliary Systems" of the NuScale design certification application.
The enclosure to this letter is the non proprietary version of the presentation entitled "ACRS Full Committee Presentation: NuScale Chapter 9, Auxiliary Systems," PM-0319-64807, Revision 0.
This letter makes no regulatory commitments and no revisions to any existing regulatory commitments.
If you have any qu*estions, please contact Carrie Fosaaen at 541-452-7126 or at cfosaaen@nuscalepower.com.
Sine~~
~~
/z::;;;;
Rad Director, Regulatory Affairs NuScale Power, LLC Distribution:
Robert Taylor, NRC, OWFN-8H12 Michael Snodderly, NRC, TWFN-2E26 Samuel Lee, NRC, OWFN-8H12 Gregory Cranston, NRC, OWFN-8H12 Getachew Tesfaye, NRC, OWFN-8H12
Enclosure:
"ACRS Full Committee Presentation: NuScale Chapter 9, Auxiliary Systems," PM-0319-64807, Revision 0 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscaleoower.com
L0-0419-64807
Enclosure:
"ACRS Full Committee Presentation: NuScale Chapter 9, Auxiliary Systems," PM-0319-64807, Revision 0 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvallis, Oregon 97330 Office 541.360-0500 Fax 541.207.3928 www.nuscalepower.com
PM-0319-64807 Revision: 0 NuScale Nonproprietary ACRS Full Committee Presentation:
NuScale Chapter 9, Auxiliary Systems Copyright 2019 by NuScale Power, LLC.
w t:i.Y.f:i£~.~;~"
Template#: 0000-21727-F01 R5
2 PM-0319-64807 Revision: 0 Presentation Team Scott Harris Supervisor, Mechanical Systems
- Corrie Nichol, Ph.D.
Refueling and Remote Handling Zackary Rad Director, Regulatory Affairs Zach Houghton Manager, Mechanical Design Copyright 2019 by NuScale Power, LLC.
N ~!:'.~.l;;~b.§.
Template#: 0000-21727-F01 R5
Reactor Building Crane
- RBC Design
- Designed to ASME NOG-1 Type 1 (Meets NUREG-0554 requirements)
- Designed to be Seismic Category 1 (Required to withstand earthquake stress and retain load.)
- Movement uses redundant position control system interlocks
- Risk Significant
- RBC has augmented Quality Control per Part Ill of the QAPD (because of Risk Significance)
- Augmented requirements conform to regulatory requirements. (SRP 9.1.5, NUREG-0554, NUREG-0612, and RG 1.13)
- Non-Safety
- The RBC doesn't perform any functions that meet the regulatory definition of safety-*related.
3 PM-0319-64807 Revision: 0 Copyright 2019 by NuScale Power, LLC.
i-1 f!!J.~"~-~-~g '
Template#: 0000-21727-F01 R5
RBC Control System
- Redundant limit switches
-"'. Hoist overtravel (upper limit switches, lower limit switches)
- Hoist overload
- Interlocks
- Slack rope and Hoist drum rope mis-spooling
- Hoist overspeed
- Unbalanced load
- Reactor building crane-fuel handling machine (FHM) interlock
- Bridge and trolley overtravel limits
- Safe Load Paths
- Restricted handling path and speed (30 fUmin traverse, 2 fUmin hoist)
- Operator monitored 4
PM-0319-64807 Revision: 0 Copyright 2019 by NuScale Power, LLC.
W t!!:l.~.~!h.r Template#: 0000-21727-F01 R5
RBC Control System
- E-stop system
- Physical relay controlled - no software
- Cuts power to motors and brakes (stops motors, sets brakes)
- Independent of any controls used for normal operation
- Redundant Physical Load Control Systems
- Redundant gearboxes, cables, brakes on main hoist
- Redundant elements are all capable of performing their 5
PM-0319-64807 Revision: 0 function individually at full load Copyright 2019 by NuScale Power, LLC.
N ~~.~-~~!..~.
Template#: 0000-21727-F01 R5
RBC Control System
- In the event of failure of load lift control system:
- Redundant upper travel limit switches
- Two-blocking capable (Hard upper limit doesn't damage RBC)
- Raise to top of travel - fuel still covered, shielding maintained, reactor module base is 29 feet above the floor
- In the event of a failure of travel control system:
- Traverse speed limited, operator monitors motion, speed is slow enough to enable operator to protect from impacts (30 ft/min)
- Energy absorbing hard stops, designed to protect in event of redundant limit switch failure (at end of travel for bridge and trolley) 6 PM-0319-64807 Revision: 0 Copyright 2019 by NuScale Power, LLC.
N t!!:l.~.f.!h~
- Template#: 0000-21727-F01 R5
Digital l&C Design and Development
- Design and development of any RBC software-based components follows a rigorous quality assurance program to ensure high quality and reliable operation based on the safety and risk significance.
- RBC is nonsafety-related, risk-significant which invokes SIL 3
- Independent verification and validation is required for SIL 3 and SIL 4 digital l&C.
- NuScale Digital l&C Software Quality Assurance Program described in DCA Section 7.2.1, and complies with ASME NQA-1-2008 and NQA-1a-2009 7
PM-0319-64807 Revision: 0 Copyright 2019 by NuScale Power, LLC.
W
~!:'.~.fA~g..
Template#: 0000-21727-F01 R5
Initial Testing Program ASME NOG-1 and Other Required Controls Testing (from DCA Table 14.2-52 and 14.2-52a)
- E-stop functionality
- Functional testing of controls and components
- Full load test
- Test limit switches
- Test speed limit at full load
- Two-blocking
- Brake function (redundant brakes for hoist and travel)
- Lowering speed limit and lowering brake test 8
PM-0319-64807 Revision: 0 Copyright 2019 by NuScale Power, LLC.
w
~!:'.~"~~b.§"
Template#: 0000-21727-F01 R5
Initial Testing Program Prerequisites
- Site Acceptance Testing
- Rated Load Test -ASME NOG Hoists (Main, Aux and Wet)
- Rated Load Test -ANSI N14.6 - MLA and NPM lift fixture
- Instrument Calibrations completed Component Testing
- Controls - interlocks and limits on RBC motion tested
- Loss of Control/Power or Seismic event - Results in no movement of bridge trolley, all hoists and brakes are set 9
PM-0319-64807 Revision: 0 Copyright 2019 by NuScale Power, LLC.
i-1 ~!!.li.~~b§"
Template#: 0000-21727-F01 RS
Initial Testing Program Component Testing (continued)
- Load Path Verification includes:
- speeds - max limits enforced
- bridge/trolley movement - toggles from full speed to microspeed when in proximity to reference locations - other NPMs or load path boundary
- Main hoist movement - elevation enforced and proximity
- Main hoist rotation
- Full seating of NPM in reactor bay receiver 10 PM-0319-64807 Revision: 0 Copyright 2019 by NuScale Power, LLC.
N ~!:)g:.~hg*
Template#: 0000-21727-F01 R5
ITAAC ITAAC 03.10.01
- ASME NOG-1 Inspection of main hoist machinery - redundant and non-redundant structural components - bridge, trolley, wire rope drum, hook, drive train, two-blocking and overload ITAAC 03.10.02 and 03.10.03
- ASME NOG-1 main hoist Full Load (100o/o) and Rated Load (125°/o) testing ITAAC 03.10.05 and 03.10.06
- ASME NOG-1 aux and wet hoists Full Load and Rated Load testing 11 PM-0319-64807 Revision: 0 Copyright 2019 by NuScale Power, LLC.
w
!'!!:'.~.f~b.~.
Template#: 0000-21727-F01 R5
ITAAC ITAAC 03.10.07
- ANSI N 14.6 MLA single load path tested to 300°/o of Manufacturer's rating
- ANSI N14.6 MLA dual load path tested to 150°/o of Manufacturer's rating
- ANSI N14.6 MLA load bearing welds undergo NOE testing ITAAC 03.10.10
- ANSI N14.6 MLA inspection of lifting arms and pinned clevis 12 PM-0319-64807 Revision: 0 Copyright 2019 by NuScale Power, LLC.
N ti!:'.~-~.!.~~..
Template#: 0000-21727-F01 R5
Pool Liner
- Liner Functions:
- Protect concrete from the borated pool water.
- Collect pool leakage and direct to sumps.
- Seismic Category I
- High sump level alarms in control room 13 PM-0319-64807 Revision: 0 Copyright 2019 by NuScale Power, LLC.
LRWS
- ! NUSCALE..
~
e ow** lo, u ll hcmo o, bnd Template#: 0000-21727-F01 R5
Pool Liner
- RXB floor slab is 1 O feet of reinforced concrete
- RXB floor slab is capable of withstanding a module drop from maximum hook height without damaging the concrete in such as a way as to cause significant damage to RXB concrete
- Pool liner rupture would result in negligible loss from UHS inventory
- Flooding would fill gaps and channels between liner and RXB concrete 14 PM-0319-64807 Revision: 0 Copyright 2019 by NuScale Power, LLC.
w ri!:'.~"~~-~g.
Template#: 0000-21727-F01 R5
Reactor Pool Mixing
- Spent Fuel Pool Cooling System
- 2x 1250 gpm pump & heat exchanger trains
- Reactor Pool Cooling System
- 3x 1250 gpm pump & heat exchanger trains
- Combined minimum operating flow (1 SFPCS / 1 RPCS)
- 3.6 Million gallons/ day (-7 Million gallon pool)
- Sample points on discharge of RPCS, SFPCS, and PCUS
- Conductivity monitors on outlet of RPCS, SFPCS, and PCUS
- Conductivity mismatch between systems could indicate a difference in boron concentration between pools 15 PM-0319-64807 Revision: 0 Copyright 2019 by NuScale Power, LLC.
W
~!:'.~"fA~~.
Template#: 0000-21727-F01 R5
Reactor Pool Mixing X = SAMPLING POINT 0 = CONDUCTIVITY INSTRUMENT RPCS ~ox-==--
,~==;;;;;;;;;:;;;;;11===~====;r=========;i
=
=
II II 1,
..-----... ----... ----... --... --1*-... ----.... --... ---....
Dry Dock 11-
.. 0000000 pa,JI~.....
..... 0000000 Vl u
c...
LL Vl 16 PM-031 9-64807 Revision: 0 0000000 0000000 OOCJCJCJCJCJ CJ CJ CJ CJ CJ CJ CJ ooooc C]C]
000000 Refueling Pool Reactor Pool G 000000 Copyright 2019 by NuScale Power, LLC.
- ! NUSCALE..
~
e ow o, l o, ull hsmork;nd Template#: 0000-21727-F01 R5
Reactor Pool Mixing
- Shutdown Margin verified by TS 3.1.1
- SR 3.1.1.1 (will use samples from RPCS to verify pool boron concentration)
- Every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />
- Every 31 Days
- And within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> after each solution volume increase of> 15,000 gal 17 PM-0319-64807 Revision: 0 Copyright 2019 by NuScale Power, LLC.
N
~!:'.~.~-~-~.~ -
Template#: 0000-21727-F01 R5
- ANSI -American National Standards Institute
- NPM - NuScale Power Module
- ASME - American Society of Mechanical
- PCS - Plant Control System Engineers
- QAPD - Quality Assurance Program Description
- aux - Auxiliary
- PCUS-Pool Cleanup System
- CNV - Containment Vessel
- RBC - Reactor Building Crane
- DCA - Design Certification Application
- RFT-Refueling Tool
- E-Stop - Emergency Stop
- RG - Regulatory Guide
- FHM - Fuel Handling Machine
- RPCS - Reactor Pool Cooling System
- ft-feet
- gpm - gallons per minute
- RXB - Reactor Building
- l&C - Instrument and Control
- SFPCS - Spent Fuel Pool Cooling System
- ITAAC - Inspections, Tests, Analyses, and Acceptance Criteria
- SIL-Software Integrity Level
- MCS - Module Control System
- SR - Surveillance Requirement
- min - minute
- SRP - Standard Review Plan
- MLA - Module Lifting Adapter *
- TS - Technical Specification
- UHS - Ultimate Heat Sink 18 PM-0319-64807 Revision: 0 Copyright 2019 by NuScale Power, LLC.
w
~!:l.~.~~!.r Template#: 0000-21727-F01 R5
Portland Office 6650 SW Redwood Lane, Suite 210 Porlland, OR 97224 971.371.1592 Corvallis Office 1100 NE Circle Blvd., Suite 200 Corvallis, OR 97330 541.360.0500 Rockville Office 11333 Woodglen Ave., Suite 205 Rockville, MD 20852 301. 770.0472 Charlotte Office 2815 Coliseum Centre Drive, Suite 230 Charlotte, NC 28217 980.349.4804 Richland Office 1933 Jadwin Ave., Suite 130 Richland, WA 99354 541.360.0500 Arlington Office 2300 Clarendon Blvd., Suite 1110 Arlington, VA 22201 London Office 1st Floor Porlland House Bressenden Place London SW1 E 5BH United Kingdom