| 05000272/LER-1990-001, :on 900106,containment purge/pressure-vacuum Relief Sys Isolation Signal Actuated as Result of Channel Spike on Particulate Radiation Monitor 1R11A.Caused by Dirty Pc Cards.Cards Cleaned & Connectors Checked |
- on 900106,containment purge/pressure-vacuum Relief Sys Isolation Signal Actuated as Result of Channel Spike on Particulate Radiation Monitor 1R11A.Caused by Dirty Pc Cards.Cards Cleaned & Connectors Checked
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000311/LER-1990-001-01, :on 900101,general Area Radiation Monitoring Sys Monitor Spiked Into Alarm Resulting in Second Automatic Switching of Control Room Ventilation.Caused by Design/ Equipment Concerns.Channel Reset |
- on 900101,general Area Radiation Monitoring Sys Monitor Spiked Into Alarm Resulting in Second Automatic Switching of Control Room Ventilation.Caused by Design/ Equipment Concerns.Channel Reset
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000272/LER-1990-002-01, :on 900117 & 0201,containment Purge/Pressure Vacuum Relief Sys Isolation Signals Initiated Due to Failures of Radiation Monitor Channel 1R41.Caused by Design/ Equipment Problem.Control Modules Reseated |
- on 900117 & 0201,containment Purge/Pressure Vacuum Relief Sys Isolation Signals Initiated Due to Failures of Radiation Monitor Channel 1R41.Caused by Design/ Equipment Problem.Control Modules Reseated
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000311/LER-1990-002, :on 900104,determined That ECCS Flow Balance Verification Surveillance Not Correctly Calculated After Last Refueling Outage on 881023.Caused by Personnel Error. Discretionary Enforcement Granted by NRC |
- on 900104,determined That ECCS Flow Balance Verification Surveillance Not Correctly Calculated After Last Refueling Outage on 881023.Caused by Personnel Error. Discretionary Enforcement Granted by NRC
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(1) |
| 05000272/LER-1990-003-01, :on 900122,plant Vent Radioactive Noble Gas Monitor 1R41C Spiked High,Causing Containment Purge/Pressure Vaccum Relief Sys Isolation Signal.Caused by Problems W/ Victoreen Detector.Channel Relay Repaired |
- on 900122,plant Vent Radioactive Noble Gas Monitor 1R41C Spiked High,Causing Containment Purge/Pressure Vaccum Relief Sys Isolation Signal.Caused by Problems W/ Victoreen Detector.Channel Relay Repaired
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000311/LER-1990-003, :on 900105,steam Generator 22 Blowdown Radiation Monitoring Sys Channel 2R19B Failed.Caused by Design/Equipment Concerns.Radiation Monitoring Sys Monitors & Modules Reseated |
- on 900105,steam Generator 22 Blowdown Radiation Monitoring Sys Channel 2R19B Failed.Caused by Design/Equipment Concerns.Radiation Monitoring Sys Monitors & Modules Reseated
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000272/LER-1990-004-01, :on 900124,spurious Actuation Signal for Containment Purge/Pressure Vacuum Relief Sys Isolation Received.Probably Caused by Failed Radiation Monitoring Sys Channel.Sys Design Mods Underway |
- on 900124,spurious Actuation Signal for Containment Purge/Pressure Vacuum Relief Sys Isolation Received.Probably Caused by Failed Radiation Monitoring Sys Channel.Sys Design Mods Underway
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000311/LER-1990-004, :on 900112,plant Vent Noble Gas Monitor 2R41A Channel Failed Low,Resulting in Containment Purge/Pressure Vacuum Relief Sys Isolation Signal.Caused by Problems W/ Victoreen Monitor.Channel Module Adjusted |
- on 900112,plant Vent Noble Gas Monitor 2R41A Channel Failed Low,Resulting in Containment Purge/Pressure Vacuum Relief Sys Isolation Signal.Caused by Problems W/ Victoreen Monitor.Channel Module Adjusted
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000272/LER-1990-005-01, :on 900220,radiation Monitoring Sys Plant Vent Radioactive Noble Gas Monitor Channel Began Intermittently Spiking High Resulting in Containment Purge.Caused by Design /Equipment Problem.Equipment Replaced |
- on 900220,radiation Monitoring Sys Plant Vent Radioactive Noble Gas Monitor Channel Began Intermittently Spiking High Resulting in Containment Purge.Caused by Design /Equipment Problem.Equipment Replaced
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000311/LER-1990-005, :on 900117,Tech Spec Action Statement 3.0.3 Entered Due to Inoperability of Two High Head ECCS Subsys. Caused by Leak from Welded Pipe Cap on Boron Injection Tank. Pipe-to-cap Socket Welded Joint Repaired |
- on 900117,Tech Spec Action Statement 3.0.3 Entered Due to Inoperability of Two High Head ECCS Subsys. Caused by Leak from Welded Pipe Cap on Boron Injection Tank. Pipe-to-cap Socket Welded Joint Repaired
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(1) |
| 05000272/LER-1990-006-01, :on 900302,ESF Actuation & Containment Ventilation Isolation Occurred.Caused by Design/Equipment Problem.Channel Backplane Replaced & Functional Test Completed |
- on 900302,ESF Actuation & Containment Ventilation Isolation Occurred.Caused by Design/Equipment Problem.Channel Backplane Replaced & Functional Test Completed
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000311/LER-1990-006, :on 900117,control Room General Area Radiation Monitor Spiked High,Resulting in Switching Ventilation Sys to Emergency Mode of Operation.Caused by Damaged Pins on Channel Backplate & Modules.Pins Repaired |
- on 900117,control Room General Area Radiation Monitor Spiked High,Resulting in Switching Ventilation Sys to Emergency Mode of Operation.Caused by Damaged Pins on Channel Backplate & Modules.Pins Repaired
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000272/LER-1990-007-01, :on 900321,found Tech Spec Surveillance for Containment Spray Not Performed Historically.Root Cause of Event Attributed to Past Inadequate Administrative Controls. Administrative Procedure Revised |
- on 900321,found Tech Spec Surveillance for Containment Spray Not Performed Historically.Root Cause of Event Attributed to Past Inadequate Administrative Controls. Administrative Procedure Revised
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 05000311/LER-1990-007, :on 900117,main Steam Line Isolation Signal Actuated During Surveillance for Pressure Transmitter, Causing Isolation Signal & ESF Actuations.Caused by Inadequate Procedure.Panel Labeling Corrected |
- on 900117,main Steam Line Isolation Signal Actuated During Surveillance for Pressure Transmitter, Causing Isolation Signal & ESF Actuations.Caused by Inadequate Procedure.Panel Labeling Corrected
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000311/LER-1990-008, :on 900120,plant Vent Noble Gas Monitor 2R41C Failed Low,Resulting in Closure Signal for Waste Gas Decay Tank Vent Control Valve 2WG41.Caused by Personnel Error. Operator Aid Will Be Posted on Panel |
- on 900120,plant Vent Noble Gas Monitor 2R41C Failed Low,Resulting in Closure Signal for Waste Gas Decay Tank Vent Control Valve 2WG41.Caused by Personnel Error. Operator Aid Will Be Posted on Panel
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000272/LER-1990-008-01, :on 900327,controlled Shutdown Commenced,Per Tech Spec Action Statement Due to Inoperability of Safeguards Equipment Controls Cabinet 1A.Caused by Equipment Failure.Spare Chassis Installed |
- on 900327,controlled Shutdown Commenced,Per Tech Spec Action Statement Due to Inoperability of Safeguards Equipment Controls Cabinet 1A.Caused by Equipment Failure.Spare Chassis Installed
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown |
| 05000311/LER-1990-009, :on 900123,plant Vent Radioactive Iodine Monitor Channel Spiked High Resulting in Containment Purge/ pressure-vacuum Relief Sys Isolation Signal.Caused by Design & Equipment Problems.Scaler Test Jack Replaced |
- on 900123,plant Vent Radioactive Iodine Monitor Channel Spiked High Resulting in Containment Purge/ pressure-vacuum Relief Sys Isolation Signal.Caused by Design & Equipment Problems.Scaler Test Jack Replaced
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000272/LER-1990-009-01, :on 900328,main Steamline Isolation Signal Actuated During Performance of Channel I Main Steamline Flow Calibr.Caused by Inadequate Procedure.Main Steamline Flow Detector Calibr Procedure Revised |
- on 900328,main Steamline Isolation Signal Actuated During Performance of Channel I Main Steamline Flow Calibr.Caused by Inadequate Procedure.Main Steamline Flow Detector Calibr Procedure Revised
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000311/LER-1990-010, :on 900216,containment Radioactive Iodine Monitor Radiation Monitoring Sys Channel Failed Low.Caused by Design/Equipment Concerns.Sys Design Mods Will Be Implemented to Eliminate ESF Actuation Signals |
- on 900216,containment Radioactive Iodine Monitor Radiation Monitoring Sys Channel Failed Low.Caused by Design/Equipment Concerns.Sys Design Mods Will Be Implemented to Eliminate ESF Actuation Signals
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000272/LER-1990-010-01, :on 900403,reactor Trip Signal Initiated Due to lo-lo Level in Steam Generator 12.Caused by Personnel Error. Event Reviewed by Operations Dept Mgt & Personnel Involved Held Accountable |
- on 900403,reactor Trip Signal Initiated Due to lo-lo Level in Steam Generator 12.Caused by Personnel Error. Event Reviewed by Operations Dept Mgt & Personnel Involved Held Accountable
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000311/LER-1990-011, :on 900301,containment Ventilation Isolation Signal (ESF) Occurred.Caused by Equipment Failure.Frayed Wire Repaired & Functional Surveillance Requirement Modified to Include Insp of Wire |
- on 900301,containment Ventilation Isolation Signal (ESF) Occurred.Caused by Equipment Failure.Frayed Wire Repaired & Functional Surveillance Requirement Modified to Include Insp of Wire
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000272/LER-1990-011-01, :on 900406,turbine Trip & Feedwater Isolation Actuation Occurred on Steam Generator 14 hi-hi Level. Caused by Equipment Failure.Valve Stem on Valve 12TB10 Polished & Adjusted |
- on 900406,turbine Trip & Feedwater Isolation Actuation Occurred on Steam Generator 14 hi-hi Level. Caused by Equipment Failure.Valve Stem on Valve 12TB10 Polished & Adjusted
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000311/LER-1990-012, :on 900403,radiation Monitoring Sys Plant Vent Radioactive Noble Gas Monitor 2R41C Lost Power Resulting in Isolation in Containment purge/pressure-vacuum Relief Sys. Cause Not Determined |
- on 900403,radiation Monitoring Sys Plant Vent Radioactive Noble Gas Monitor 2R41C Lost Power Resulting in Isolation in Containment purge/pressure-vacuum Relief Sys. Cause Not Determined
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000272/LER-1990-012-01, :on 900409,reactor Trip on Steam Generator 12 lo-lo Level Occurred.Caused by Equipment Failure.Steam Generator 12 Governor Valve Linkage Repaired |
- on 900409,reactor Trip on Steam Generator 12 lo-lo Level Occurred.Caused by Equipment Failure.Steam Generator 12 Governor Valve Linkage Repaired
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000272/LER-1990-013, :on 900410,radiation Monitoring Sys Channel 1R12A Spiked Into Alarm,Resulting in ESF Actuation Signal. Caused by Failure of Electrical Signal Connectors &/Or Electronic Circuit Connections.Repairs Made |
- on 900410,radiation Monitoring Sys Channel 1R12A Spiked Into Alarm,Resulting in ESF Actuation Signal. Caused by Failure of Electrical Signal Connectors &/Or Electronic Circuit Connections.Repairs Made
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000311/LER-1990-013-01, :on 900416,discovered That Setpoint for 2R11A & 2R12A Monitors for Radiation Monitoring Sys Channels Not Changed During Last Refueling Outage.Caused by Inadequate Administrative Control.Procedure Revised |
- on 900416,discovered That Setpoint for 2R11A & 2R12A Monitors for Radiation Monitoring Sys Channels Not Changed During Last Refueling Outage.Caused by Inadequate Administrative Control.Procedure Revised
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(1) |
| 05000311/LER-1990-014, :on 900419,ESF Actuation Signal for Containment Ventilation Isolation Occurred.Caused by Procedural Inadequacy.Setpoint Setting Modified & Detector Time Constant Extended from 20 to 40 |
- on 900419,ESF Actuation Signal for Containment Ventilation Isolation Occurred.Caused by Procedural Inadequacy.Setpoint Setting Modified & Detector Time Constant Extended from 20 to 40
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(b)(2)(ii) |
| 05000272/LER-1990-014-01, :on 900409,determined That Last Calculated Safety Injection Pump Flow Rate for Pumps 12 & 21 Greater than 650 Gpm.Caused by Personnel Error & Procedural Deficiencies.New Orifice Plates Installed |
- on 900409,determined That Last Calculated Safety Injection Pump Flow Rate for Pumps 12 & 21 Greater than 650 Gpm.Caused by Personnel Error & Procedural Deficiencies.New Orifice Plates Installed
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 05000311/LER-1990-015, :on 900415,ESF Signal Actuation for Containment Ventilation Isolation Occurred.Caused by Procedural Inadequacy.Setpoint Setting Modified & Detector Time Constant Extended from 20 to 40 |
- on 900415,ESF Signal Actuation for Containment Ventilation Isolation Occurred.Caused by Procedural Inadequacy.Setpoint Setting Modified & Detector Time Constant Extended from 20 to 40
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000272/LER-1990-015-01, :on 900430,control Room Intake Radiation Monitor 1R1B Alarm Circuitry Failed,Resulting in Switching Control Room Ventilation from Normal to Accident Mode. Caused by Short in Bulb.Bulbs Replaced |
- on 900430,control Room Intake Radiation Monitor 1R1B Alarm Circuitry Failed,Resulting in Switching Control Room Ventilation from Normal to Accident Mode. Caused by Short in Bulb.Bulbs Replaced
| |
| 05000272/LER-1990-016-01, :on 900419,determined That Six Fast Closure Turbine Bldg Svc Water Sys Isolation Valves Could Not Be Counted on to Function During Design Base Event.Caused by Inadequate Design |
- on 900419,determined That Six Fast Closure Turbine Bldg Svc Water Sys Isolation Valves Could Not Be Counted on to Function During Design Base Event.Caused by Inadequate Design
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function |
| 05000311/LER-1990-016, :on 900420,discovered That Containment Pressure Relief Conducted W/Associated Radiation Monitoring Sys Channels Inoperable.Caused by Inoperability of Control Room Pump Low Flow Alarm.Procedures Revised |
- on 900420,discovered That Containment Pressure Relief Conducted W/Associated Radiation Monitoring Sys Channels Inoperable.Caused by Inoperability of Control Room Pump Low Flow Alarm.Procedures Revised
| 10 CFR 50.73(a)(2)(1) |
| 05000272/LER-1990-017-01, :on 900507,high Head Safety Injection Pumps Failed to Meet Seismic Criteria.Caused by Equipment Mfg Failure to Complete Required Welding.Intermediate Head Safety Injection Pumps Design Reviewed |
- on 900507,high Head Safety Injection Pumps Failed to Meet Seismic Criteria.Caused by Equipment Mfg Failure to Complete Required Welding.Intermediate Head Safety Injection Pumps Design Reviewed
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function |
| 05000311/LER-1990-017, :on 900501,inadvertent Manual Safety Injection Occurred Due to Personnel Error.Technician Made Assumption Re Wiring Changes Performed.Train B Wiring Corrected & Deficiency Rept Initiated |
- on 900501,inadvertent Manual Safety Injection Occurred Due to Personnel Error.Technician Made Assumption Re Wiring Changes Performed.Train B Wiring Corrected & Deficiency Rept Initiated
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000272/LER-1990-018, :on 900528,control Room Air Intake Radiation Monitoring Sys Monitor Alarm Circuitry Failed & on 900701, Channel 1R1B Failed Resulting in Actuation of ESF Function. Caused by Spurious High Channel Spike |
- on 900528,control Room Air Intake Radiation Monitoring Sys Monitor Alarm Circuitry Failed & on 900701, Channel 1R1B Failed Resulting in Actuation of ESF Function. Caused by Spurious High Channel Spike
| |
| 05000272/LER-1990-018-01, :on 900528,ESF Actuation Involving Control Room Ventilation Switch Occurred.Caused by Spurious High Channel Spike.Channel Functional Test Successfully Completed on 900611 |
- on 900528,ESF Actuation Involving Control Room Ventilation Switch Occurred.Caused by Spurious High Channel Spike.Channel Functional Test Successfully Completed on 900611
| 10 CFR 50.73(a)(2) |
| 05000311/LER-1990-018, :on 900511,containment Purge/Pressure Vacuum Relief Sys Actuated.Caused by Design/Equipment Failures. Lighting Transformer 2HL Replaced |
- on 900511,containment Purge/Pressure Vacuum Relief Sys Actuated.Caused by Design/Equipment Failures. Lighting Transformer 2HL Replaced
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000272/LER-1990-019-01, :on 900603,main Steam Line Isolation Actuation Occurred & Bistables for Low Steam Line Pressure Logic Tripped.Caused by Equipment/Design Concerns W/Sensing Lines. Design Mods Re Flow Instrumentation Underway |
- on 900603,main Steam Line Isolation Actuation Occurred & Bistables for Low Steam Line Pressure Logic Tripped.Caused by Equipment/Design Concerns W/Sensing Lines. Design Mods Re Flow Instrumentation Underway
| 10 CFR 50.73(a)(2) |
| 05000311/LER-1990-019, :on 900511,ESF Actuation Occurred When Radioactive Noble Gas Monitor 2R12A RMS Channel Spiked High. Caused by Equipment/Design Failures.Several Sys Design Mods Will Eliminate Spurious Actuation |
- on 900511,ESF Actuation Occurred When Radioactive Noble Gas Monitor 2R12A RMS Channel Spiked High. Caused by Equipment/Design Failures.Several Sys Design Mods Will Eliminate Spurious Actuation
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000272/LER-1990-020-01, :on 900608,identified That maint-I&C Procedures for Setting Intermediate Range Excore Nuclear Instrumentation Sys Permissive P-6 Not Correct.Caused by Inadequate Procedure Control |
- on 900608,identified That maint-I&C Procedures for Setting Intermediate Range Excore Nuclear Instrumentation Sys Permissive P-6 Not Correct.Caused by Inadequate Procedure Control
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 05000311/LER-1990-020, :on 900512,containment purge/pressure-vacuum Relief Sys Isolation Signal Received from Radiation Monitoring Sys.Caused by Equipment Design Concerns. Uninterruptible Power Supply Installed |
- on 900512,containment purge/pressure-vacuum Relief Sys Isolation Signal Received from Radiation Monitoring Sys.Caused by Equipment Design Concerns. Uninterruptible Power Supply Installed
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000311/LER-1990-021, :on 900515,radiation Monitoring Sys Channel 2R12A Failed Resulting in ESF Signal Actuation for Containment Purge/Pressure Vacuum Relief Sys Isolation. Caused by Equipment/Design Concerns |
- on 900515,radiation Monitoring Sys Channel 2R12A Failed Resulting in ESF Signal Actuation for Containment Purge/Pressure Vacuum Relief Sys Isolation. Caused by Equipment/Design Concerns
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000272/LER-1990-021-01, :on 900717,discovered That Work Order Not Issued to Perform Revised Procedure 1IC-16.1.008.Caused by Personnel Error.Event Reviewed by Technical Department Mgt Appropriate Personnel |
- on 900717,discovered That Work Order Not Issued to Perform Revised Procedure 1IC-16.1.008.Caused by Personnel Error.Event Reviewed by Technical Department Mgt Appropriate Personnel
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 05000272/LER-1990-022-01, :on 900717,observed That Relief Valve 1SJ167 Was Leaking Past Seat as Result of Investigation to Determine Cause of Decreasing Level in Accumulators.Caused by Equipment Failure.Valve Repaired on 900722 |
- on 900717,observed That Relief Valve 1SJ167 Was Leaking Past Seat as Result of Investigation to Determine Cause of Decreasing Level in Accumulators.Caused by Equipment Failure.Valve Repaired on 900722
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 05000311/LER-1990-022, :on 900522,radiation Monitoring Sys Channel 2R12A Failed Low.Probably Caused by Equipment/Design Concerns.Anticipates That Several Sys Design Mods Will Eliminate Spurious ESF Actuation Signals |
- on 900522,radiation Monitoring Sys Channel 2R12A Failed Low.Probably Caused by Equipment/Design Concerns.Anticipates That Several Sys Design Mods Will Eliminate Spurious ESF Actuation Signals
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000311/LER-1990-023, :on 900516,4 Kv Vital Bus Deenergized During 2A Safeguard Equipment Control 18-month Surveillance.Caused by Personnel Error.Personnel Reprimanded & Procedure M3U Revised |
- on 900516,4 Kv Vital Bus Deenergized During 2A Safeguard Equipment Control 18-month Surveillance.Caused by Personnel Error.Personnel Reprimanded & Procedure M3U Revised
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000272/LER-1990-023-01, :on 900725,discovered That Surveillance of Svc Water Sys Check Valves Not Completed Per Inservice Testing Program Manual Requirements.Caused by Inadequate Administrative Controls.Program Modified |
- on 900725,discovered That Surveillance of Svc Water Sys Check Valves Not Completed Per Inservice Testing Program Manual Requirements.Caused by Inadequate Administrative Controls.Program Modified
| 10 CFR 50.73(a)(2)(i) |
| 05000311/LER-1990-024, :on 900521,T-handle Instrument Isolation Valve Discovered Closed,Resulting in Isolation of Liquid Radwaste Effluent Line Monitor 2R18.Caused by Personnel Error.Valve Added to Tagging Request Info Sys Data Base |
- on 900521,T-handle Instrument Isolation Valve Discovered Closed,Resulting in Isolation of Liquid Radwaste Effluent Line Monitor 2R18.Caused by Personnel Error.Valve Added to Tagging Request Info Sys Data Base
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function |
| 05000272/LER-1990-024-01, :on 900728,discovered That Interlock Functions for P-10 & P-12 Permissives Not Fully Tested Per Tech Spec Surveillance 4.3.1.1.2.Caused by Inadequate Administrative Controls.Procedures Revised to Address Testing |
- on 900728,discovered That Interlock Functions for P-10 & P-12 Permissives Not Fully Tested Per Tech Spec Surveillance 4.3.1.1.2.Caused by Inadequate Administrative Controls.Procedures Revised to Address Testing
| |
| 05000272/LER-1990-025-01, :on 900806,control Room Air Intake Radiation Sys Monitor Alarm Circuitry Spiked High Resulting in Automatic Switching of Ventilation to Accident Mode of Operation.Addl Spikes Occurred on 900807 & 08 |
- on 900806,control Room Air Intake Radiation Sys Monitor Alarm Circuitry Spiked High Resulting in Automatic Switching of Ventilation to Accident Mode of Operation.Addl Spikes Occurred on 900807 & 08
| 10 CFR 50.73(a)(2)(iv), System Actuation |