ANALYTICAL REPORT TestAmerica Laboratories, Inc.

TestAmerica St. Louis 13715 Rider Trail North Earth City, MO 63045 Tel: (314)298-8566 TestAmerica Job ID: 160-11761-1 Client Project/Site: HDP For:

Perma-Fix Environmental Services Inc.

2800 Solway Road Knoxville, Tennessee 37931 Attn: Brian Miller Authorized for release by:

5/20/2015 12:30:00 PM Ivan Vania, Project Manager II (314)298-8566 ivan.vania@testamericainc.com This report has been electronically signed and authorized by the signatory. Electronic signature is intended to be the legally binding equivalent of a traditionally handwritten signature.

Results relate only to the items tested and the sample(s) as received by the laboratory.

1 2

3 4

5 6

7 8

9 10 11 12

Table of Contents Client: Perma-Fix Environmental Services Inc.

Project/Site: HDP TestAmerica Job ID: 160-11761-1 Page 2 of 18 Cover Page..............................................

1 Table of Contents.........................................

2 Case Narrative...........................................

3 Chain of Custody..........................................

5 Receipt Checklists.........................................

6 Definitions/Glossary.......................................

7 Method Summary.........................................

8 Sample Summary.........................................

9 Client Sample Results......................................

10 QC Sample Results........................................

13 QC Association Summary...................................

16 Tracer Carrier Summary....................................

18 1

2 3

4 5

6 7

8 9

10 11 12

Case Narrative Client: Perma-Fix Environmental Services Inc.

TestAmerica Job ID: 160-11761-1 Project/Site: HDP Job ID: 160-11761-1 Laboratory: TestAmerica St. Louis Narrative CASE NARRATIVE Client: Perma-Fix Environmental Services Inc.

Project: HDP Report Number: 160-11761-1 With the exceptions noted as flags or footnotes, standard analytical protocols were followed in the analysis of the samples and no problems were encountered or anomalies observed. In addition all laboratory quality control samples were within established control limits, with any exceptions noted below. Each sample was analyzed to achieve the lowest possible reporting limit within the constraints of the method. In some cases, due to interference or analytes present at high concentrations, samples were diluted. For diluted samples, the reporting limits are adjusted relative to the dilution required.

TestAmerica St. Louis attests to the validity of the laboratory data generated by TestAmerica facilities reported herein. All analyses performed by TestAmerica facilities were done using established laboratory SOPs that incorporate QA/QC procedures described in the application methods. TestAmericas operations groups have reviewed the data for compliance with the laboratory QA/QC plan, and data have been found to be compliant with laboratory protocols unless otherwise noted below.

The test results in this report meet all NELAP requirements for parameters for which accreditation is required or available. Any exceptions to NELAP requirements are noted in this report. Pursuant to NELAP, this report may not be reproduced, except in full, without the written approval of the laboratory.

Calculations are performed before rounding to avoid round-off errors in calculated results.

All holding times were met and proper preservation noted for the methods performed on these samples, unless otherwise detailed in the individual sections below.

All solid sample results for Chemistry analyses are reported on an "as received" basis unless otherwise indicated by the presence of a %

solids value in the method header. All soil/sediment sample results for radiochemistry analyses are based upon sample as dried and disaggregated with the exception of tritium, carbon-14, and iodine-129 by gamma spectroscopy unless requested as wet weight by the client.

This laboratory report is confidential and is intended for the sole use of TestAmerica and its client.

RECEIPT The samples were received on 05/08/2015; the samples arrived in good condition, properly preserved and, where required, on ice. The temperature of the coolers at receipt was 20.0 C.

TECHNETIUM-99 (ICPMS)

Samples L10-04-15-B-E-B-00 (160-11761-1), L10-04-16-B-E-B-00 (160-11761-2), L10-12-15-B-E-B-00 (160-11761-3) and L10-12-16-B-E-B-00 (160-11761-4) were analyzed for Technetium-99 (ICPMS) in accordance with EPA SW-846 Method 6020A. The samples were prepared on 05/12/2015 and analyzed on 05/13/2015.

No analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page.

PERCENT SOLIDS Samples L10-04-15-B-E-B-00 (160-11761-1), L10-04-16-B-E-B-00 (160-11761-2), L10-12-15-B-E-B-00 (160-11761-3) and L10-12-16-B-E-B-00 (160-11761-4) were analyzed for percent solids in accordance with EPA Method 160.3 MOD. The samples were analyzed on 05/12/2015.

TestAmerica St. Louis Page 3 of 18 1

2 3

4 5

6 7

8 9

10 11 12

Case Narrative Client: Perma-Fix Environmental Services Inc.

TestAmerica Job ID: 160-11761-1 Project/Site: HDP Job ID: 160-11761-1 (Continued)

Laboratory: TestAmerica St. Louis (Continued)

No analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page.

CESIUM-137 & OTHER GAMMA EMITTERS (GS)

Samples L10-04-15-B-E-B-00 (160-11761-1), L10-04-16-B-E-B-00 (160-11761-2), L10-12-15-B-E-B-00 (160-11761-3) and L10-12-16-B-E-B-00 (160-11761-4) were analyzed for Cesium-137 & Other Gamma Emitters (GS) in accordance with DOE GA-01-R. The samples were leached on 05/11/2015, prepared on 05/13/2015 and analyzed on 05/15/2015.

Preparation Batch 190575:

Radium-226 is reported in these samples at the clients request. Radium-226 is reported from the 609.31 keV line of bismuth-214.

Because the samples have not had a 21-day ingrowth, the activity for radium-226 is an estimated value and may be biased low. This bias is caused by the disruption of secular equilibrium between radium-226 and bismuth-214 by the loss of radon-222 during sample preparation. L10-04-15-B-E-B-00 (160-11761-1), L10-04-16-B-E-B-00 (160-11761-2), L10-12-15-B-E-B-00 (160-11761-3),

L10-12-16-B-E-B-00 (160-11761-4), (LCS 160-190575/2-A), (MB 160-190575/1-A), (160-11778-A-21-E) and (160-11778-A-21-I DU)

No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page.

TestAmerica St. Louis Page 4 of 18 1

2 3

4 5

6 7

8 9

10 11 12

Page 5 of 18 1

2 3

4 5

6 7

8 9

10 11 12 TestAmerica st. Louis 13715 Rider Trail North Chain of Custody Record TestAmerica Earth City, MO 63045 phone 314.298.8566 fax Client Contact Perma-Fix Environmental Services 2800 Solway Road Knoxville, TN 37931

{865) 690--0501 Phone (865) 539-9868 FAX Project Name: Hematite Decommissioning Project Site: Westinghouse Hematite, MO P0#832953 Sample Identification L10-04-15-B-E-B-OO L 10-04-16-B-E-B-OO L 10-12-15-B-E-B-OO L 10-12-16-B-E-B-OO I ~

Regulatory Program: D DW QNPDES Project Manager: Brian Miller Tel/Fax: (314) 810-3333 Analysis Turnaround Time 0 CALENDAR DAYS D WORKING DAYS TAT if different from Below D

2 weeks 0

1 week 0

2days D

!day _

...,.,.~

Type Sample I Sample I (C--Comp,

  1. of Date Time G=GrabJ Matrix conl 5/8/15 0900 G

Soil 1

5/8/15 0905 G

Soil 1

5/8/15 0925 G

Soil 1

5/8/15 0930 G

Soil 1

~

THE LEADER IN ENVIRONMENTAL TESTING 0RCRA 0 other:

TestAmerica Laboratories, Inc.

Site

Contact:

Ellen Jakub

!Date: 05/08/2015 COG No: 050815-FSS1 Lab

Contact:

Ivan Vanya

!Carrier: Courier 1

of 1

COCs

?;-

Sampler:

l!!

J:).

2 z
i i

-- i e

Z>

Cl

~g

~

c

.S!:;;

a, "C

Q. -

t> Ill l~

E u,., ::,

<)

~

Q. 0 u, J::

Q.

.., E

"' Cl u, u, ~ &

~ E.!:..

~

~ J2 E.;

.s=

=

J::

~.~...,

a.

~I u.. 0..

C, 3: < 2 For Lab Use Only:

Walk-in Client I

I Lab Sampling:

Job I SDG No.:

Sample Specific Notes:

N X

X X

Matt Cushman N

X X

X Matt Cushman N

X X

X Matt Cushman N

X X

X Brian Miller --

--1---L.. _.. L..... t.. 1.. L..... L.. J.~

N

/

A \\

\\\\11111\\\\1111\\

160-11761 Chain of custody


,*-****-*****T * ***--**r ** t' - -r**-***--r** -r**-"-;,-._

__+--

tt-+/---L i-t-+-l F'le/i&:~$:gn~ilfWI~~ ~~'Rfff}ilip1¥J.ttt~s~~i~!lttt~Jt~~1;1;$ '91:~tt~~

~Ji'.~W4:$~m!!:,ttf/!i11til'P,:\\!rcr~%i%t&sz.:'$ii Possible Hazard Identification:

Sample Disposal ( A fee may be assessed if samples are retained longer than 1 month)

Are any samples from a listed EPA Hazardous Waste? Please List any EPA Waste Codes for the sample in the Comments Section if the lab is to dispose of the sample.

0 Non-Hazard O Flammable D Skin Irritant O Poison B O Unknown 0 Return to rnent D Disposal by t.ab 0 An:hive for Months Specia.1 Instructions/QC Requirements & Comments: Potential for Radiological Contamination Custody Seajs Intact_

0_Yes _O No Custody Seal No.:

-Corr'o:-- -- Therm ID No.:

Datemme:

X S: "8* I

)45/

Reli~~~

Relinquished by:

Company:

Date/Time:

Relinquished by:

Company:

Date/Time:

Received in Laboratory by:

Company:

Date/Time:

I Hematite Oecommionirng Project I

Permanx: {fur Westinghouse'} Won-~eta1y Oass 3 I Procedt.'fe:HDP-PfU}A-006, Chain af Castodf I R-e<ision: 3 !

Login Sample Receipt Checklist Client: Perma-Fix Environmental Services Inc.

Job Number: 160-11761-1 Login Number: 11761 Question Answer Comment Creator: Daniels, Brian J List Source: TestAmerica St. Louis List Number: 1 True Radioactivity wasn't checked or is </= background as measured by a survey meter.

True The cooler's custody seal, if present, is intact.

N/A Sample custody seals, if present, are intact.

True The cooler or samples do not appear to have been compromised or tampered with.

False Samples were received on ice.

Thermal preservation not required.

True Cooler Temperature is acceptable.

True Cooler Temperature is recorded.

True COC is present.

True COC is filled out in ink and legible.

True COC is filled out with all pertinent information.

False Is the Field Sampler's name present on COC?

True There are no discrepancies between the containers received and the COC.

True Samples are received within Holding Time.

True Sample containers have legible labels.

True Containers are not broken or leaking.

True Sample collection date/times are provided.

True Appropriate sample containers are used.

True Sample bottles are completely filled.

True Sample Preservation Verified.

True There is sufficient vol. for all requested analyses, incl. any requested MS/MSDs N/A Containers requiring zero headspace have no headspace or bubble is

<6mm (1/4").

True Multiphasic samples are not present.

True Samples do not require splitting or compositing.

N/A Residual Chlorine Checked.

TestAmerica St. Louis Page 6 of 18 1

2 3

4 5

6 7

8 9

10 11 12

Definitions/Glossary TestAmerica Job ID: 160-11761-1 Client: Perma-Fix Environmental Services Inc.

Project/Site: HDP Qualifiers Metals Qualifier Description J

Result is less than the RL but greater than or equal to the MDL and the concentration is an approximate value.

Qualifier Rad Qualifier Description U

Result is less than the sample detection limit.

Qualifier Glossary These commonly used abbreviations may or may not be present in this report.

Listed under the "D" column to designate that the result is reported on a dry weight basis Abbreviation

%R Percent Recovery CFL Contains Free Liquid CNF Contains no Free Liquid DER Duplicate error ratio (normalized absolute difference)

Dil Fac Dilution Factor DL, RA, RE, IN Indicates a Dilution, Re-analysis, Re-extraction, or additional Initial metals/anion analysis of the sample DLC Decision level concentration MDA Minimum detectable activity EDL Estimated Detection Limit MDC Minimum detectable concentration MDL Method Detection Limit ML Minimum Level (Dioxin)

NC Not Calculated ND Not detected at the reporting limit (or MDL or EDL if shown)

PQL Practical Quantitation Limit QC Quality Control RER Relative error ratio RL Reporting Limit or Requested Limit (Radiochemistry)

RPD Relative Percent Difference, a measure of the relative difference between two points TEF Toxicity Equivalent Factor (Dioxin)

TEQ Toxicity Equivalent Quotient (Dioxin)

TestAmerica St. Louis Page 7 of 18 1

2 3

4 5

6 7

8 9

10 11 12

Method Summary TestAmerica Job ID: 160-11761-1 Client: Perma-Fix Environmental Services Inc.

Project/Site: HDP Method Method Description Laboratory Protocol SW846 6020A Metals (ICP/MS), Tc-99 TAL SL EPA Moisture Percent Moisture TAL SL SW846 6020A Metals (ICP/MS), Tc-99 in Activity TAL SL DOE GA-01-R Cesium-137 & Other Gamma Emitters (GS)

TAL SL Protocol

References:

DOE = U.S. Department of Energy EPA = US Environmental Protection Agency SW846 = "Test Methods For Evaluating Solid Waste, Physical/Chemical Methods", Third Edition, November 1986 And Its Updates.

Laboratory

References:

TAL SL = TestAmerica St. Louis, 13715 Rider Trail North, Earth City, MO 63045, TEL (314)298-8566 TestAmerica St. Louis Page 8 of 18 1

2 3

4 5

6 7

8 9

10 11 12

Sample Summary TestAmerica Job ID: 160-11761-1 Client: Perma-Fix Environmental Services Inc.

Project/Site: HDP Lab Sample ID Client Sample ID Received Collected Matrix 160-11761-1 L10-04-15-B-E-B-00 Solid 05/08/15 09:00 05/08/15 16:51 160-11761-2 L10-04-16-B-E-B-00 Solid 05/08/15 09:05 05/08/15 16:51 160-11761-3 L10-12-15-B-E-B-00 Solid 05/08/15 09:25 05/08/15 16:51 160-11761-4 L10-12-16-B-E-B-00 Solid 05/08/15 09:30 05/08/15 16:51 TestAmerica St. Louis Page 9 of 18 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-11761-1 Client: Perma-Fix Environmental Services Inc.

Project/Site: HDP Lab Sample ID: 160-11761-1 Client Sample ID: L10-04-15-B-E-B-00 Matrix: Solid Date Collected: 05/08/15 09:00 Percent Solids: 94.5 Date Received: 05/08/15 16:51 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000054 0.000016 mg/Kg

05/12/15 10:41 05/13/15 17:43 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.195 (2+/-)

0.128 (2+/-)

1 05/13/15 17:43 05/12/15 10:41 pCi/g 0.185 1.08 RL MDC 0.126 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 05/12/15 10:41 05/13/15 17:43 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 98 Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS)

Analyte Actinium 228 0.387 (2+/-)

0.0895 (2+/-)

1 05/15/15 08:42 05/13/15 12:41 pCi/g 0.0653 RL MDC 0.0802 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 05/13/15 12:41 05/15/15 08:42 1

0.0808 0.0482 0.0482 U

-0.0159 Americium 241 pCi/g 05/13/15 12:41 05/15/15 08:42 1

0.406 0.247 0.246 U

0.190 Bismuth 212 pCi/g 05/13/15 12:41 05/15/15 08:42 1

0.0444 0.0886 0.0711 0.509 Bismuth 214 pCi/g 05/13/15 12:41 05/15/15 08:42 1

0.0543 0.0705 0.0495 0.388 Lead 212 pCi/g 05/13/15 12:41 05/15/15 08:42 1

0.0482 0.0909 0.0701 0.558 Lead 214 pCi/g 05/13/15 12:41 05/15/15 08:42 1

0.243 1.00 0.723 6.80 Potassium 40 pCi/g 05/13/15 12:41 05/15/15 08:42 1

3.89 2.13 2.13 U

0.665 Protactinium 234m pCi/g 05/13/15 12:41 05/15/15 08:42 1

0.786 0.169 0.167 U

0.214 Protactinium 231 pCi/g 05/13/15 12:41 05/15/15 08:42 1

0.0444 0.0886 0.0711 0.509 Radium 226 pCi/g 05/13/15 12:41 05/15/15 08:42 1

0.699 0.586 0.571 1.27 Thorium 234 pCi/g 05/13/15 12:41 05/15/15 08:42 1

0.194 0.104 0.104 U

0.0905 Uranium 235 pCi/g 05/13/15 12:41 05/15/15 08:42 1

0.0653 0.0895 0.0802 0.387 Thorium 232 Tl-208 0.134 0.0285 0.0317 0.0207 pCi/g 05/13/15 12:41 05/15/15 08:42 1

(2+/-)

(2+/-)

MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.

Uncert.

Lab Sample ID: 160-11761-2 Client Sample ID: L10-04-16-B-E-B-00 Matrix: Solid Date Collected: 05/08/15 09:05 Percent Solids: 74.8 Date Received: 05/08/15 16:51 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 0.000034 J 0.000068 0.000020 mg/Kg

05/12/15 10:41 05/13/15 17:47 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.589 (2+/-)

0.127 (2+/-)

1 05/13/15 17:47 05/12/15 10:41 pCi/g 0.231 1.35 RL MDC 0.114 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 05/12/15 10:41 05/13/15 17:47 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 99 TestAmerica St. Louis Page 10 of 18 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-11761-1 Client: Perma-Fix Environmental Services Inc.

Project/Site: HDP Lab Sample ID: 160-11761-2 Client Sample ID: L10-04-16-B-E-B-00 Matrix: Solid Date Collected: 05/08/15 09:05 Date Received: 05/08/15 16:51 Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS)

Analyte Actinium 228 1.00 (2+/-)

0.159 (2+/-)

1 05/15/15 08:43 05/13/15 12:42 pCi/g 0.0955 RL MDC 0.123 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 05/13/15 12:42 05/15/15 08:43 1

0.0998 0.240 0.240 U

-0.0184 Americium 241 pCi/g 05/13/15 12:42 05/15/15 08:43 1

0.235 0.368 0.335 1.49 Bismuth 212 pCi/g 05/13/15 12:42 05/15/15 08:43 1

0.0676 0.136 0.0990 0.900 Bismuth 214 pCi/g 05/13/15 12:42 05/15/15 08:43 1

0.0679 0.138 0.0694 0.921 Lead 212 pCi/g 05/13/15 12:42 05/15/15 08:43 1

0.0644 0.125 0.0790 0.930 Lead 214 pCi/g 05/13/15 12:42 05/15/15 08:43 1

0.392 1.94 1.06 16.1 Potassium 40 pCi/g 05/13/15 12:42 05/15/15 08:43 1

4.48 2.90 2.88 U

3.71 Protactinium 234m pCi/g 05/13/15 12:42 05/15/15 08:43 1

0.941 0.341 0.336 U

0.556 Protactinium 231 pCi/g 05/13/15 12:42 05/15/15 08:43 1

0.0676 0.136 0.0990 0.900 Radium 226 pCi/g 05/13/15 12:42 05/15/15 08:43 1

0.827 0.345 0.300 1.62 Thorium 234 pCi/g 05/13/15 12:42 05/15/15 08:43 1

0.211 0.180 0.175 0.385 Uranium 235 pCi/g 05/13/15 12:42 05/15/15 08:43 1

0.0955 0.159 0.123 1.00 Thorium 232 Tl-208 0.279 0.0420 0.0509 0.0344 pCi/g 05/13/15 12:42 05/15/15 08:43 1

(2+/-)

(2+/-)

MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.

Uncert.

Lab Sample ID: 160-11761-3 Client Sample ID: L10-12-15-B-E-B-00 Matrix: Solid Date Collected: 05/08/15 09:25 Percent Solids: 83.8 Date Received: 05/08/15 16:51 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000063 0.000019 mg/Kg

05/12/15 10:41 05/13/15 17:51 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99

-0.0729 U (2+/-)

0.0191 (2+/-)

1 05/13/15 17:51 05/12/15 10:41 pCi/g 0.216 1.26 RL MDC 0.0179 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 05/12/15 10:41 05/13/15 17:51 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 95 Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS)

Analyte Actinium 228 1.25 (2+/-)

0.172 (2+/-)

1 05/15/15 09:03 05/13/15 12:42 pCi/g 0.0945 RL MDC 0.117 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 05/13/15 12:42 05/15/15 09:03 1

0.0912 0.0549 0.0548 U

-0.0267 Americium 241 pCi/g 05/13/15 12:42 05/15/15 09:03 1

0.319 0.347 0.326 1.12 Bismuth 212 pCi/g 05/13/15 12:42 05/15/15 09:03 1

0.0686 0.142 0.0989 0.976 Bismuth 214 pCi/g 05/13/15 12:42 05/15/15 09:03 1

0.0577 0.177 0.0741 1.24 Lead 212 pCi/g 05/13/15 12:42 05/15/15 09:03 1

0.0806 0.150 0.0925 1.13 Lead 214 pCi/g 05/13/15 12:42 05/15/15 09:03 1

0.295 1.97 1.07 16.1 Potassium 40 pCi/g 05/13/15 12:42 05/15/15 09:03 1

4.96 2.86 2.85 U

0.843 Protactinium 234m pCi/g 05/13/15 12:42 05/15/15 09:03 1

1.11 0.681 0.677 U

-0.603 Protactinium 231 TestAmerica St. Louis Page 11 of 18 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-11761-1 Client: Perma-Fix Environmental Services Inc.

Project/Site: HDP Lab Sample ID: 160-11761-3 Client Sample ID: L10-12-15-B-E-B-00 Matrix: Solid Date Collected: 05/08/15 09:25 Date Received: 05/08/15 16:51 Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS) (Continued)

Analyte Radium 226 0.976 (2+/-)

0.142 (2+/-)

1 05/15/15 09:03 05/13/15 12:42 pCi/g 0.0686 RL MDC 0.0989 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 05/13/15 12:42 05/15/15 09:03 1

0.685 0.274 0.260 0.808 Thorium 234 pCi/g 05/13/15 12:42 05/15/15 09:03 1

0.240 0.135 0.135 U

0.0561 Uranium 235 pCi/g 05/13/15 12:42 05/15/15 09:03 1

0.0945 0.172 0.117 1.25 Thorium 232 Tl-208 0.423 0.0532 0.0690 0.0392 pCi/g 05/13/15 12:42 05/15/15 09:03 1

(2+/-)

(2+/-)

MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.

Uncert.

Lab Sample ID: 160-11761-4 Client Sample ID: L10-12-16-B-E-B-00 Matrix: Solid Date Collected: 05/08/15 09:30 Percent Solids: 81.9 Date Received: 05/08/15 16:51 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 0.00029 0.000063 0.000019 mg/Kg

05/12/15 10:41 05/13/15 17:56 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 5.01 (2+/-)

0.584 (2+/-)

1 05/13/15 17:56 05/12/15 10:41 pCi/g 0.217 1.27 RL MDC 0.360 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 05/12/15 10:41 05/13/15 17:56 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 96 Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS)

Analyte Actinium 228 0.897 (2+/-)

0.147 (2+/-)

1 05/15/15 11:08 05/13/15 12:42 pCi/g 0.100 RL MDC 0.115 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

pCi/g 05/13/15 12:42 05/15/15 11:08 1

0.0963 0.0572 0.0572 U

0.00596 Americium 241 pCi/g 05/13/15 12:42 05/15/15 11:08 1

0.475 0.316 0.312 0.480 Bismuth 212 pCi/g 05/13/15 12:42 05/15/15 11:08 1

0.0694 0.122 0.0970 0.709 Bismuth 214 pCi/g 05/13/15 12:42 05/15/15 11:08 1

0.0707 0.116 0.0673 0.733 Lead 212 pCi/g 05/13/15 12:42 05/15/15 11:08 1

0.0702 0.119 0.0833 0.814 Lead 214 pCi/g 05/13/15 12:42 05/15/15 11:08 1

0.345 1.90 1.11 15.1 Potassium 40 pCi/g 05/13/15 12:42 05/15/15 11:08 1

5.33 1.53 1.52 U

1.64 Protactinium 234m pCi/g 05/13/15 12:42 05/15/15 11:08 1

1.12 0.199 0.196 U

0.316 Protactinium 231 pCi/g 05/13/15 12:42 05/15/15 11:08 1

0.0694 0.122 0.0970 0.709 Radium 226 pCi/g 05/13/15 12:42 05/15/15 11:08 1

0.780 0.264 0.257 U

0.567 Thorium 234 pCi/g 05/13/15 12:42 05/15/15 11:08 1

0.230 0.143 0.143 U

0.0410 Uranium 235 pCi/g 05/13/15 12:42 05/15/15 11:08 1

0.100 0.147 0.115 0.897 Thorium 232 Tl-208 0.307 0.0423 0.0530 0.0265 pCi/g 05/13/15 12:42 05/15/15 11:08 1

(2+/-)

(2+/-)

MDC RL Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Other Detected Radionuclides Uncert.

Uncert.

TestAmerica St. Louis Page 12 of 18 1

2 3

4 5

6 7

8 9

10 11 12

QC Sample Results TestAmerica Job ID: 160-11761-1 Client: Perma-Fix Environmental Services Inc.

Project/Site: HDP Method: 6020A - Metals (ICP/MS), Tc-99 Client Sample ID: Method Blank Lab Sample ID: MB 160-190451/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 190705 Prep Batch: 190451 RL MDL Technetium 99 ND 0.000049 0.000015 mg/Kg 05/12/15 10:41 05/13/15 15:56 1

MB MB Analyte Dil Fac Analyzed Prepared D

Unit Result Qualifier Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-190451/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 190705 Prep Batch: 190451 Technetium 99 0.00122 0.00126 mg/Kg 103 80 - 120 Analyte LCS LCS D

Unit Result Qualifier

%Rec Spike Added

%Rec.

Limits Client Sample ID: Matrix Spike Lab Sample ID: 160-11745-A-1-C MS Matrix: Solid Prep Type: Total/NA Analysis Batch: 190705 Prep Batch: 190451 Technetium 99 ND 0.00155 0.00162 mg/Kg 104 75 - 125

Analyte MS MS D

Unit Result Qualifier

%Rec Spike Added Sample Result Sample Qualifier

%Rec.

Limits Client Sample ID: Matrix Spike Duplicate Lab Sample ID: 160-11745-A-1-D MSD Matrix: Solid Prep Type: Total/NA Analysis Batch: 190705 Prep Batch: 190451 Technetium 99 ND 0.00156 0.00160 mg/Kg 102 75 - 125 1

30

Analyte MSD MSD D

Unit Result Qualifier

%Rec Spike Added Sample Result Sample Qualifier

%Rec.

Limits Limit RPD RPD Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Client Sample ID: Method Blank Lab Sample ID: MB 160-190451/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 190706 Prep Batch: 190451 Technetium 99 Analyte U

1 05/13/15 15:56 05/12/15 10:41 pCi/g 0.167 MDC 0.976 RL 0.0375 0.0353 (2+/-)

(2+/-)

MB

-0.1376 MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert.

Count Uncert.

Total Carrier Re 30 - 110 05/12/15 10:41 05/13/15 15:56 1

Dil Fac Prepared Analyzed Qualifier Limits

%Yield 102 MB MB Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-190451/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 190706 Prep Batch: 190451 Technetium 99 Analyte 120 80 103 21.64 20.9 2.03 0.999 0.171 RL MDC (2+/-)

LCS LCS pCi/g Unit Result Qual

%Rec Added Spike Limits

%Rec.

Uncert.

Total Re Carrier 30 - 110 LCS Qualifier Limits

%Yield 99 LCS TestAmerica St. Louis Page 13 of 18 1

2 3

4 5

6 7

8 9

10 11 12

QC Sample Results TestAmerica Job ID: 160-11761-1 Client: Perma-Fix Environmental Services Inc.

Project/Site: HDP Method: 6020A - Metals (ICP/MS), Tc-99 in Activity (Continued)

Client Sample ID: Matrix Spike Lab Sample ID: 160-11745-A-1-C MS Matrix: Solid Prep Type: Total/NA Analysis Batch: 190706 Prep Batch: 190451 Technetium 99 Analyte 125 75 103 27.66 26.5 0.294 2.88 1.29 0.221 RL MDC (2+/-)

MS MS pCi/g Unit Result Qual

%Rec Added Spike Result Sample Sample Qual Limits

%Rec.

Uncert.

Total Re Carrier 30 - 110 MS Qualifier Limits

%Yield 97 MS Client Sample ID: Matrix Spike Duplicate Lab Sample ID: 160-11745-A-1-D MSD Matrix: Solid Prep Type: Total/NA Analysis Batch: 190706 Prep Batch: 190451 Technetium 99 Analyte 1

0.06 125 75 101 27.31 26.7 0.294 3.03 1.32 0.226 RL MDC (2+/-)

MSD MSD pCi/g Unit Result Qual

%Rec Limit Added Spike Result Sample Sample Qual Limits

%Rec.

Uncert.

Total RER RER Re Carrier 30 - 110 MSD Qualifier Limits

%Yield 96 MSD Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS)

Client Sample ID: Method Blank Lab Sample ID: MB 160-190575/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 191179 Prep Batch: 190575 Actinium 228 Analyte U

1 05/17/15 19:09 05/13/15 12:27 pCi/g 0.0605 MDC RL 0.0342 0.0342 (2+/-)

(2+/-)

MB 0.01494 MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert.

Count Uncert.

Total 1

05/17/15 19:09 05/13/15 12:27 pCi/g 0.0180 0.0109 0.0109 U

0.007940 Americium 241 1

05/17/15 19:09 05/13/15 12:27 pCi/g 0.151 0.0755 0.0755 U

0.006267 Bismuth 212 1

05/17/15 19:09 05/13/15 12:27 pCi/g 0.0406 0.0328 0.0328 U

-0.007054 Bismuth 214 1

05/17/15 19:09 05/13/15 12:27 pCi/g 0.0280 0.251 0.251 U

-0.006280 Lead 212 1

05/17/15 19:09 05/13/15 12:27 pCi/g 0.0276 0.0134 0.0134 U

-0.0000467 8

Lead 214 1

05/17/15 19:09 05/13/15 12:27 pCi/g 0.352 3.54 3.54 U

-0.08855 Potassium 40 1

05/17/15 19:09 05/13/15 12:27 pCi/g 2.36 0.679 0.679 U

-0.2024 Protactinium 234m 1

05/17/15 19:09 05/13/15 12:27 pCi/g 0.277 0.144 0.144 U

-0.001046 Protactinium 231 1

05/17/15 19:09 05/13/15 12:27 pCi/g 0.0406 0.0328 0.0328 U

-0.007054 Radium 226 1

05/17/15 19:09 05/13/15 12:27 pCi/g 0.281 0.285 0.285 U

-0.07798 Thorium 234 1

05/17/15 19:09 05/13/15 12:27 pCi/g 0.0594 0.0429 0.0429 U

-0.002380 Uranium 235 1

05/17/15 19:09 05/13/15 12:27 pCi/g 0.0605 0.0342 0.0342 U

0.01494 Thorium 232 Other Detected Radionuclide None MB (2+/-)

(2+/-)

MDC RL pCi/g 05/13/15 12:27 05/17/15 19:09 1

MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert.

Count Uncert.

Total Radionuclides Other Detected TestAmerica St. Louis Page 14 of 18 1

2 3

4 5

6 7

8 9

10 11 12

QC Sample Results TestAmerica Job ID: 160-11761-1 Client: Perma-Fix Environmental Services Inc.

Project/Site: HDP Method: GA-01-R - Cesium-137 & Other Gamma Emitters (GS) (Continued)

Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-190575/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 191182 Prep Batch: 190575 Americium 241 Analyte 116 87 104 104.5 101 10.9 0.571 RL MDC (2+/-)

LCS LCS pCi/g Unit Result Qual

%Rec Added Spike Limits

%Rec.

Uncert.

Total Cesium 137 34.8 37.49 3.88 0.200 0.185 pCi/g 108 87 - 120 Cobalt 60 35.6 37.61 3.73 0.134 pCi/g 106 87 - 115 Client Sample ID: Duplicate Lab Sample ID: 160-11778-A-21-I DU Matrix: Solid Prep Type: Total/NA Analysis Batch: 190863 Prep Batch: 190575 Actinium 228 Analyte 1

1.04 0.7094 1.03 0.147 0.120 RL MDC (2+/-)

DU DU pCi/g Unit Result Qual Limit Result Sample Sample Qual Uncert.

Total RER RER Americium 241

-0.00193 U 0.008331 U 0.0488 0.0822 pCi/g 0.08 1

Bismuth 212 1.21 1.069 0.436 0.371 pCi/g 0.17 1

Bismuth 214 0.642 0.6860 0.116 0.0652 pCi/g 0.20 1

Lead 212 0.899 0.9439 0.138 0.0444 pCi/g 0.16 1

Lead 214 0.745 0.7675 0.116 0.0630 pCi/g 0.1 1

Potassium 40 16.6 14.88 1.84 0.214 pCi/g 0.46 1

Protactinium 234m 2.29 U 1.442 U 2.76 4.68 pCi/g 0.16 1

Protactinium 231

-0.435 U

-0.5688 U 0.678 1.11 pCi/g 0.10 1

Radium 226 0.642 0.6860 0.116 0.0652 pCi/g 0.20 1

Thorium 234 0.883 0.6537 U 0.278 0.731 pCi/g 0.31 1

Uranium 235 0.0799 U 0.1779 0.130 0.161 pCi/g 0.39 1

Thorium 232 1.03 0.7094 0.147 0.120 pCi/g 1.04 1

Tl-208 1

0.38 0.2727 0.311 0.0489 0.0270 RL MDC (2+/-)

DU DU pCi/g Unit Result Qual Limit Result Sample Sample Qual Uncert.

RER RER Total Other Detected Radionuclides TestAmerica St. Louis Page 15 of 18 1

2 3

4 5

6 7

8 9

10 11 12

QC Association Summary TestAmerica Job ID: 160-11761-1 Client: Perma-Fix Environmental Services Inc.

Project/Site: HDP Metals Prep Batch: 190451 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid None 160-11745-A-1-C MS Matrix Spike Total/NA Solid None 160-11745-A-1-D MSD Matrix Spike Duplicate Total/NA Solid None 160-11761-1 L10-04-15-B-E-B-00 Total/NA Solid None 160-11761-2 L10-04-16-B-E-B-00 Total/NA Solid None 160-11761-3 L10-12-15-B-E-B-00 Total/NA Solid None 160-11761-4 L10-12-16-B-E-B-00 Total/NA Solid None LCS 160-190451/2-A Lab Control Sample Total/NA Solid None MB 160-190451/1-A Method Blank Total/NA Analysis Batch: 190705 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid 6020A 190451 160-11745-A-1-C MS Matrix Spike Total/NA Solid 6020A 190451 160-11745-A-1-D MSD Matrix Spike Duplicate Total/NA Solid 6020A 190451 160-11761-1 L10-04-15-B-E-B-00 Total/NA Solid 6020A 190451 160-11761-2 L10-04-16-B-E-B-00 Total/NA Solid 6020A 190451 160-11761-3 L10-12-15-B-E-B-00 Total/NA Solid 6020A 190451 160-11761-4 L10-12-16-B-E-B-00 Total/NA Solid 6020A 190451 LCS 160-190451/2-A Lab Control Sample Total/NA Solid 6020A 190451 MB 160-190451/1-A Method Blank Total/NA General Chemistry Analysis Batch: 190415 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Moisture 160-11761-1 L10-04-15-B-E-B-00 Total/NA Solid Moisture 160-11761-1 DU L10-04-15-B-E-B-00 Total/NA Solid Moisture 160-11761-2 L10-04-16-B-E-B-00 Total/NA Solid Moisture 160-11761-3 L10-12-15-B-E-B-00 Total/NA Solid Moisture 160-11761-4 L10-12-16-B-E-B-00 Total/NA Rad Leach Batch: 190248 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Dry and Grind 160-11761-1 L10-04-15-B-E-B-00 Total/NA Solid Dry and Grind 160-11761-2 L10-04-16-B-E-B-00 Total/NA Solid Dry and Grind 160-11761-3 L10-12-15-B-E-B-00 Total/NA Solid Dry and Grind 160-11761-4 L10-12-16-B-E-B-00 Total/NA Leach Batch: 190284 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Dry and Grind 160-11778-A-21-I DU Duplicate Total/NA Prep Batch: 190451 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid None 160-11745-A-1-C MS Matrix Spike Total/NA Solid None 160-11745-A-1-D MSD Matrix Spike Duplicate Total/NA Solid None 160-11761-1 L10-04-15-B-E-B-00 Total/NA Solid None 160-11761-2 L10-04-16-B-E-B-00 Total/NA Solid None 160-11761-3 L10-12-15-B-E-B-00 Total/NA TestAmerica St. Louis Page 16 of 18 1

2 3

4 5

6 7

8 9

10 11 12

QC Association Summary TestAmerica Job ID: 160-11761-1 Client: Perma-Fix Environmental Services Inc.

Project/Site: HDP Rad (Continued)

Prep Batch: 190451 (Continued)

Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid None 160-11761-4 L10-12-16-B-E-B-00 Total/NA Solid None LCS 160-190451/2-A Lab Control Sample Total/NA Solid None MB 160-190451/1-A Method Blank Total/NA Prep Batch: 190575 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Fill_Geo-0 190248 160-11761-1 L10-04-15-B-E-B-00 Total/NA Solid Fill_Geo-0 190248 160-11761-2 L10-04-16-B-E-B-00 Total/NA Solid Fill_Geo-0 190248 160-11761-3 L10-12-15-B-E-B-00 Total/NA Solid Fill_Geo-0 190248 160-11761-4 L10-12-16-B-E-B-00 Total/NA Solid Fill_Geo-0 190284 160-11778-A-21-I DU Duplicate Total/NA Solid Fill_Geo-0 LCS 160-190575/2-A Lab Control Sample Total/NA Solid Fill_Geo-0 MB 160-190575/1-A Method Blank Total/NA TestAmerica St. Louis Page 17 of 18 1

2 3

4 5

6 7

8 9

10 11 12

Tracer/Carrier Summary TestAmerica Job ID: 160-11761-1 Client: Perma-Fix Environmental Services Inc.

Project/Site: HDP Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Prep Type: Total/NA Matrix: Solid Lab Sample ID Client Sample ID (30-110)

Re 97 160-11745-A-1-C MS Percent Yield (Acceptance Limits)

Matrix Spike 96 160-11745-A-1-D MSD Matrix Spike Duplicate 98 160-11761-1 L10-04-15-B-E-B-00 99 160-11761-2 L10-04-16-B-E-B-00 95 160-11761-3 L10-12-15-B-E-B-00 96 160-11761-4 L10-12-16-B-E-B-00 99 LCS 160-190451/2-A Lab Control Sample 102 MB 160-190451/1-A Method Blank Tracer/Carrier Legend Re = Re TestAmerica St. Louis Page 18 of 18 1

2 3

4 5

6 7

8 9

10 11 12