Siemens Power Corporation Nuclear Division EMF-92-178 Palisades Cycle 11 :

Disposition and Analysis of Standard Review Plan Chapter 15 Events December 1992

. Siemens Power Corporation Nuclear Division 9302040163 930129 PDR ADOCK 05000255 p

PDR

~*

ATTACHMENT 3 Consumers Power Company Palisades Plant Docket 50-255 EMF-92-178 PALISADES CYCLE 11:

DISPOSITION AND ANALYSIS OF STANDARD REVIEW PLAN CHAPTER 15 EVENTS January 29, 1993

Siemens Power Corporation EMF-92-178 Issue Date:

12/21/92 PALISADES CYCLE 11: DISPOSITION AND ANALYSIS OF STANDARD REVIEW

/ljs/skm PLAN CHAPTER 15 EVENTS Contributors: C. R. Baccus S. E. Cole C. J. Lewis R.

Moore December 1992

CUSTOMER DISCLAIMER IMPORTANT NOTICE REGARDING CONTENTS AND USE OF THIS DOCUMENT PLEASE READ CAREFULLY Siemens Power Corporation's warranties and representations concerning the subject matter of this document are those set forth in the Agreement between Siemens Power Corporation and the Customer pursuant to which this document is issued.

Accordingly, except as otherwise expressly provided in such Agreement, neither Siemens Power Corporation nor any person acting on its behalf makes any warranty or representation, expressed or implied, with respect to the accuracy, completeness, or usefulness of the information contained in this document, or that the use of any information, apparatus, method or process disclosed in this document will not infringe privately owned rights; or assumes any liabilities with respect to the use of any information, apparatus, method or process disclosed in this document.

The information contained herein is for the sole use of the Customer.

In order to avoid impairment of rights of Siemens Power Corporation in patents

.or inventions which may be included in the information contained in this document, the recipient, by its acceptance of this document, agrees not to publish or make public use (in the patent use of the term) of such information until so authorized in writing by Siemens Power Corporation or until after six (6) months

. following termination or expiration of the aforesaid Agreement and any extension thereof, unless expressly provided in the Agreement. No rights or licenses in or to any patents are implied by 'the furnishing of this document.

l

TABLE OF CONTENTS EMF-92-178 Page i Section 1.0 Introduction 1

2.0 Summary and Conclusions............ :............................

2 3.0 Disposition and Analysis of Plant Events..............................

1 O 15.0 Accident Analyses.........................................

11

  • 15.0.1 Categorization of Plant Events..........................

11 15.0.2 Plant Characteristics and Initial Conditions.................

17 15.0.3 Power Distribution...................................

21 15.0.4 Range of Plant Operating Parameters and States............

24 15.0.5 Reactivity Coefficients Used in the Safety Analysis...........

26 15.0.6 Scram Insertion Characteristics.........................

28 15.0.7 Reactor Protection System Trip Setpoints and Time Delays....

30 15.0.8 Component Capacities and Setpoints.....................

43 15.0.9 Plant Systems and Components Available for Mitigation of Accident Effects.....................................

45 15.0.1 O Effects of Mixed Assembly Types and Fuel Rod Bowing......

51 15.0.11 Plant Licensing Basis and Single Failure Criteria............

52 15.1 Increase in Heat Removal by the Secondary System...............

54 15.1.1 Decrease in Feedwater Temperature......................

54 15.1.2 Increase in Feedwater Flow............................

55 15.1.3 Increase in Steam Flow...............................

55 15.1.4 Inadvertent Opening of a Steam Generator Relief or Safety Valve.............................................

58 15.1.5 Steam System Piping Failures Inside and Outside of Containment........................................

58 15.2 Decrease in Heat Removal by the Secondary System..............

60 15.2.1 Loss of External Load....................... :..........

60 15.2.2 Turbine Trip.. *......................................

61 15.2.3 Loss of Condenser Vacuum............................

62 15.2.4 Closure of the Main Steam Isolation Valves (MSIV) (BWR).....

62 15.2.5 Steam Pressure Regulator Failure........................

63 15.2.6 Loss of Nonemergency A.C. Power to the Station Auxiliaries...

63 15.2.7 Loss of Normal Feedwater Flow.........................

64 15.2.8 Feedwater System Pip~ Breaks Inside and Outside Containment........................................

65 15.3 Decrease in Reactor Coolant System Flow.......................

67 15.3.1 Loss of Forced Reactor Coolant Flow.....................

67 15.3.2 Flow Controller Malfunction............................

69 15.3.3 Reactor Coolant Pump Rotor Seizure.....................

69

TABLE OF CONTENTS EMF-92-178 Page ii Section Page 15.3.4 Reactor Coolant Pump Shaft Break......................

71 15.4 Reactivity and Power Distribution Anomalies.....................

72 15.4.1 Uncontrolled Control Rod Assembly Withdrawal from a Subcritical or Low Power Startup Condition................

72 15.4.2 Uncontrolled Control Rod Bank Withdrawal at Power.........

73 15.4.3 Control Rod Misoperation..............................

75 15.4.4 Startup of an Inactive Loop.............................

84 15.4.5 Flow Controller Malfunction............................

84 15.4.6 CVCS Malfunction that Results in a Decrease in the Boron Concentration in the Reactor Coolant.....................

85 15.4. 7 Inadvertent Loading and Operation of a Fuel Assembly in an Improper Position........ *.............. :..............

86

_ 15.4.8 Spectrum of Control Rod Ejection Accidents................

86 15.4.9 Spectrum of Rod Drop Accidents (BWR)....................

88 15.5.1 Inadvertent Operation of the ECCS that Increases Reactor Coolant Inventory..............,.....................

88 15.5.2 CVCS Malfunction that Increases Reactor Coolant Inventory....

88 15.6 Decreases in Reactor Coolant Inventory........................

90 15.6.1 Inadvertent Opening of a PWR Pressurizer Pressure Relief Valve................*........................... :

90 15.6.2 Radiological Consequences of the Failure of Small Lines Carrying Primary Coolant Outside of Containment...........

91 15.6.3 Radiological Consequences of Steam Generator Tube Failure..

92 15.6.4 Radiological Consequences of a Main Steam Line Failure Outside Containment (BWR)............................

92 15.6.5 Loss of Coolant Accidents Resulting from a Spectrum of Postulated Piping Breaks Within the Reactor Coolant Pressure Boundary................. *.........................

93 15.7 Radioactive Releases from a Subsystem or Component.............

94

. 15.7.1 Waste Gas System Failure.............................

94 15.7.2 Radioactive Liquid Waste System Leak or Failure (Release to Atmosphere)........................................

94 15.7.3 Postulated Radioactive Releases Due to Liquid-Containing Tank Failures.......................................

94 15.7.4 Radiological Consequences of Fuel Handling Accident........

94 15.7.5 Spent Fuel Cask Drop Accidents........................

95 4.0 References....................................................

96

2-1 2-2 15.0.1-1 15.0.2-1 15.0.2-2 15.0.2-3 15.0.3-1 15.0.4-1 15.0.5-1 15.0.7-1 15.0.7-2 15.0.8-1 15.0.9-1 15.4.3-1 LIST OF TABLES EMF-92-178 Page iii DISPOSITION OF EVENTS

SUMMARY

FOR PALISADES CYCLE 11.....

3

SUMMARY

OF ANALYSES RESULTS............................

8 ACCIDENT CATEGORY USED FOR EACH ANAL VZED EVENT........

14 PLANT OPERATIONAL MODES...............................

18 NOMINAL PLANT OPERATING CONDITIONS.....................

19 NOMINAL RELOAD 0 FUEL DESIGN PARAMETERS...............

20 CORE POWER DISTRIBUTION................................

22 RANGE OF KEY INITIAL CONDITION OPERATING PARAMETERS.....

25 REACTIVITY PARAMETERS..................................

27 TRIP SETPOINTS FOR OPERATION AT 2530 MWT................

38 TM/LP UNCERTAINTIES....................................

39 COMPONENT CAPACITIES AND SETPOINTS....................

44 OVERVIEW OF PLANT SYSTEMS AND EQUIPMENT AVAILABLE FOR TRANSIENT AND ACCIDENT CONDITIONS......................

46

SUMMARY

OF MDNBR AND PEAK LHR FOR CONTROL ROD MISOPERATION EVENTS...................................

83

Figure 15.0.3-1 15.0.6-1 15.0.7-1 15.0.7-2 15.0.7-3 LIST OF FIGURES EMF-92-178 Page iv LIMITING AXIAL POWER SHAPE (ASI = -0.143)...................

23 INTEGRATED SCRAM WORTH WITH MOST REACTIVE ROD STUCK OUT....................................................

29 TINLET LIMITING CONDITION OF OPERATION....................

40 AXIAL SHAPE FUNCTION FOR TM/LP TRIP......................

41 CORE PROTECTION LIMITS FOR TM/LP TRIP (ASI = +0.200).......

42

1.0 Introduction EMF-92-178 Page 1 This report documents the results of a disposition and analysis of the FSAR Chapter 14 events in support of Palisades Cycle 11 operation with up to 15.0 % steam generator tube plugging. The events were evaluated in accordance with Chapter 15 of the Standard Review Plan (SRP)(1) and Siemens Power Corporation (SPC) methodologyC2>. The changes that will be implemented for Cycle 11 include the following:

(1)

(2)

(3)

The insertion of the third full reload of fuel that utilize High Thermal Performance (HTP) grid spacers. Therefore, the mixed core penalty for differing co-resident fuel is not applied.

To accommodate a low radial leakage loading pattern, assembly (FrA) and rod (F rT) radial power peaking limits are increased for Reload 0 fuel. The proposed Technical S~ecification radial peaking factor limits for Reload 0 are 1.76 (F/)

and 2.04 (Fr ). The proposed Technical Specification radial peaking limits for all fuel loaded in Cycle 11 are given in Table 15.0.3-1.

Reinsertion of eight Reload N partial shielding assemblies (PSA) and sixteen Reload I/hafnium assemblies in low powered peripheral locations to reduce vessel fluence.

The minimum departure from nucleate boiling ratio (MDNBR) calculations using the ANFP critical heat flux correlationC9*10> were performed for Reload 0 fuel with HTP spacers and radial peaking factors of 1.76 and 2.04 for the assembly and peak rod, respectively. Radial peaking factors for reloads prior to Reload 0 will not change for Cycle 11 and are supported by References 3 and 21.

Section 2.0 presents a summary of results for this analysis. Section 3.0 presents the conditions employed in the event analyses and a discussion of the event disposition and MDNBR results for the SAP Chapter 15 events. The events are numbered in accordance with the SAP to facilitate review.

2.0 Summary and Conclusions EMF-92-178 Page 2 A summary of the Disposition of Events for Cycle 11 is given in Table 2-1. This table lists each SRP Chapter 15 event, indicates whether that event is reanalyzed for this submittal, provides a reference to the bounding event or analysis of record for events not reanalyzed and a cross reference between SRP event numbers and the Palisades Updated FSAR(S).

The results of Anticipated Operational Occurrences and Postulated Accidents reanalyzed for this submittal are listed in Table 2-2 along with a complete summary of the plant licensing basis. The MDNBR analyses performed for Cycle 11 incorporated the ANFP critical heat flux correlation, the third full reload of HTP spacer fuel, Reload 0 specific fuel design (e.g.,

fuel rod enrichments, loading, radial peaking limits, etc.) and an axial shape characteristic of full power control rod position. In general, there was a decrease in MDNBR for Cycle 11 relative to Cycle 10 due primarily to the increase in radial peaking limits supported for Reload 0 fuel. Nonetheless, the results reported herein confirm that event acceptance criteria (Section 15.0.1.1) are met for Cycle 11 operation. These results support operation with up to 15.0 %

average steam generator tube plugging at a rated thermal power of 2530 MWt. Table 2-2 also contains a compilation of the analyses results for Palisades.

SRP Event Designation 15.1 15.1.1 15.1.2 15.1.3 15.1.4 15.1.5 15.2 15.2.1 15.2.2 15.2.3 15.2.4 15.2.5 15.2.6 EMF-92-178 Page 3 TABLE 2-1 DISPOSITION OF EVENTS

SUMMARY

FOR PALISADES CYCLE 11 Bounding Updated Event or FSAR Event Name DisQosition Reference Designation INCREASE IN HEAT REMOVAL BY THE SECONDARY SYSTEM Decrease in Feedwater Temperature Bounded 15.1.3 (d)

Increase in Feedwater Flow (d)

1)

Power Bounded 15.1.3

2)

Startup Bounded 15.1.3 Increase in Steam Flow Analyze Ca>

Ref. 3Cb) 14.10 Inadvertent Opening of a Steam Generator Relief or Safety Valve

1)

Power Bounded 15.1.3

2)

Scram Shutdown Margin Bounded 15.1.3 Steam System Piping Failures Inside and Bounded Ref. 3 14.14 Outside of Containment DECREASE IN HEAT REMOVAL BY THE SECONDARY SYSTEM Loss of External Load Bounded Ref. 3 14.12 Turbine Trip Bounded 15.2.1 Loss of Condenser Vacuum Bounded 15.2.1 Closure of the Main Steam Isolation Valves Bounded 15.2.1 (MSIV)

Steam Pressure Regulator Failure Not Applicable; BWR Event Loss of Nonemergency A.C. Power to the Short term:

15.3.1 Station Auxiliaries Bounded Long term:

15.2.7 Bounded

SRP Event Designation 15.2.7 15.2.8 15.3 15.3.1 15.3.2 15.3.3 15.3.4 15.4 15.4.1 15.4.2 EMF-92-178 Page 4 TABLE 2-1 DISPOSITION OF EVENTS

SUMMARY

FOR PALISADES CYCLE 11, CONTINUED Bounding Updated Event or FSAR Event Name Dis12osition Reference Designation Loss of Normal Feedwater Flow

1)

Maximum PCS pressure Bounded Ref. 17 14.13

2)

Maximum Primary-to-Secondary Bounded Ref. 17 14.13 pressure difference

3)

Minimum steam generator inventory Bounded Ref. 17 Feedwater System Pipe Breaks Inside and Cool down:

15.1.5 Outside Containment Bounded Heatup:

15.2.1 Bounded DECREASE IN REACTOR COOLANT SYSTEM FLOW Loss of Forced Reactor Coolant Flow Analyze<a>

Ref. 3Cb>

14.7 Flow Controller Malfunction Not Applicable 14.7 Reactor Coolant Pump Rotor Seizure Analyze<a>

Ref. 3Cb>

14.7 Reactor Coolant Pump Shaft Break Bounded 15.3.3 14.7 REACTIVITY AND POWER DISTRIBUTION ANOMALIES Uncontrolled Control Rod Bank Withdrawal Bounded Ref. 3 14.2.1 from a Subcritical or Low Power Gondition Uncontrolled Control Rod Bank Withdrawal at Analyze<a>

  • Ref. a

14.2.2 Power Operation Conditions

SAP Event Designation 15.4.3 15.4.4 15.4.5 15.4.6 15.4.7 EMF-92-178

  • Page 5 TABLE 2-1 DISPOSITION OF EVENTS

SUMMARY

FOR PALISADES CYCLE 11, CONTINUED Bounding Updated Event or FSAR Event Name DiSQOSition Reference Designation Control Rod Misoperation

1)

Dropped Control Bank/Rod.

Analyze Ca>

Ref. 3Cb>

14.4

2)

Dropped Part-Length Control Rod Bounded 15.4.3(1) 14.6

3)

Malpositioning of the Part-Length Not Applicable Control Group

4)

Statically Misaligned Control Bounded.

15.4.3(1) 14.6 Rod/Bank

5)

Single Control Rod Withdrawal Analyze< a>

Ref. 8Cb>

14.2.3

6)

Core Barrel Failure Bounded 15.4.8 14.5 Startup of an Inactive Loop Bounded by 14.8 rated power MDNBR Flow Controller Malfunction Not Applicable: No Flow Controller CVCS Malfunction that Results in a Decrease in the Boron Concentration in the Reactor Coolant

1)

Rated and Power Operation Bounded Ref. 3 14.3 Conditions

2)

Reactor Critical, Hot Standby and Bounded Ref. 3 14.3 Hot Shutdown

3)

Refueling Shutdown Condition, Cold Bounded Ref. 3 14.3 Shutdown Condition and Refueling Operation Inadvertent Loading and Operation of a Fuel Administrative Assembly in an Improper Position procedures preclude this event l

SRP Event Designation 15.4.8 15.4.9 15.5 15.5.1 15.5;2 15.6 15.6.1 15.6.2 15.6.3 15.6.4 15.6.5 EMF-92-178 Page 6 TABLE 2-1 DISPOSITION OF EVENTS

SUMMARY

FOR PALISADES CYCLE 11, CONTINUED Bounding Updated Event or FSAR Event Name Dis12osition Reference Designation Spectrum of Control Rod Ejection Accidents Bounded Ref. 3 14.16 Spectrum of Rod Drop Accidents (BWR)

Not Applicable; BWR Event INCREASES IN REACTOR COOLANT INVENTORY Inadvertent Operation of the ECCS that Overpressure:

15.2.1 Increases Reactor Coolant Inventory Bounded Reactivity:

15.4.6 Bounded CVCS Malfunction that Increases Reactor Overpressure:

. 15.2.1 Coolant Inventory Bounded Reactivity:

15.4.6 Bounded DECREASES IN REACTOR COOLANT INVENTORY Inadvertent Opening of a PWR Pressurizer Analyze<aJ Ref. 3!bJ, 6 Pressure Relief Valve Radiological Consequences of the Failure of Bounded 15.6.5 14.23 Small Lines Carrying Primary Coolant Outside of Containment Radiological Consequences of Steam Bounded Ref. 6 14.15 Generator Tube Failure Radiological Consequences cit a Main Steam Not Line Failure Outside Containment Applicable; BWR Event Loss of Coolant Accidents Resulting from a Bounded Ref. 6, 14 14.17 Spectrum of Postulated Piping Breaks Within 14.18 the Reactor Coolant Pressure Boundary 14.22

EMF-92-178

  • Page 7 TABLE 2-1 DISPOSITION OF EVENTS

SUMMARY

FOR PALISADES CYCLE.11, CONTINUED SRP Bounding Updated Event Event or FSAR Designation Event Name Dis12osition Reference Designation 15.7 RADIOACTIVE RELEASE FROM A SUBSYSTEM OR COMPONENT 15.7.1 Waste Gas System Failure Bounded Ref. 6 14.21 15.7.2 Radioactive Liquid Waste System Leak or

  • Bounded Ref. 6 14.20 Failure (Release to Atmosphere) 15.7.3 Postulated Radioactive Releases due to Bounded Ref. 6 14,20 Liquid-Containing Tank Failures 15.7.4 Radiological Consequences of Fuel Handling (c) 14.19 Accidents 15.7.5 Spent Fuel Cask Drop Accidents (C) 14.11
a.

MDNBR/peak LHR analysis will be performed for Cycle 11.

b.

PTSPWR2 analysis is given reference for this event.

c.

CPCo will evaluate this event.

d.

Del~ted from the FSAR.


~----

TABLE 2-2

SUMMARY

OF ANALYSES RESULTS l\\.1AXIMUM CORE MAXIMUM MAXIMUM POWER AVERAGE HEAT PRESSURIZER PEAK EVENT< a>

LEVEL (MWt}

FLUX (BtuLhr-tt2}

PRESSURE (!;!Sia}

MDNBR(b)

LHR (kWlfll REFERENCE 15.1.3 Increase In Steam Flow 2,735.4 175, 166 2,033.12 1.587 16.98 3

15.1.5 Steam System Piping 318.0 20,272 2,060.0 Note (c) 19.00 3

Failures Inside and Outside of Containment 15.2.1 Loss of External Load 2,668.4 165,499 2,625.36 Note (d) 3 15.2.7 Loss of Normal Feedwater 2,580.6 167,000 2,271.9 Note (e) 17 15.3.1 Loss of Forced Reactor 2,686.7 165,473 2,127.78 1.178 15.58 3

Coolant Flow 15.3.3 Reactor Coolant Pump 2,743.1 165,473 2, 145.19 1.139<f>

15.98 3

Rotor Seizure 15.4.2 Uncontrolled Control Bank 2,900.9 178,867 2,267.14 1.443 17.12 8

Withdrawal at Power 15.4.3 Control Rod Mlsoperatlon

  • Dropped Rod 2,580.6 165,473 2,010 1.186 18.44 3
  • Dropped Bank 2,340.7 146,400 2,060 1.428 18.44 3
  • Single Rod Withdrawal 2,900.9 178,867 2,267.14 1.192 18.49 8

15.4.6 CVCS Malfunction Resulting Adequacy of the shutdown margin is demonstrated 3

in Decreased Boron Concentration 15.4.8 Control Rod Ejection 3,494.3 173,528 2, 115.00 Note (g) 3 m

15.6.1 Inadvertent Opening of a 2,690.4 168,558 2, 110.10 1.587 16.33 3

s::

-u -;n PWR Pressurizer Pressure ll> <D Relief Valve CC N

(!) ~

CX> CX>

TABLE 2-2

SUMMARY

OF ANALYSES RESULTS, CONTINUED EVENT< a>

15.6.3 Radiologlcal Consequences of Steam Generator Tube Failure MAXIMUM POWER LEVEL (MWt)

MAXIMUM CORE AVERAGE HEAT FLUX (Btu/hr-tt2)

MAXIMUM PRESSURIZER PRESSURE (psia)

MDNBR Radiological consequence acceptance criteria are met PEAK LHR (kW/ft)

REFERENCE 6

15.6.5 Loss of Coolant Accidents Resulting from a Spectrum of Postulated Piping Breaks within the Reactor Coolant Pressure Boundary 10 CFR 50.46(b) acceptance criteria are shown to be met

15. 7.4 Radiological Consequences of Fuel Handling Accidents 15.7.5 Spent Fuel Cask Drop Accidents CPCo will evaluate this event CPCo wlll evaluate this event
a.

Events that are reanalyzed as a result of the Cycle 11 changes are indicated in bold type.

b.

MDNBRs are based on the radial peaking assumptions given in Table 15.0.3-1 and the ANFP correlation (95/95 limit= 1.154).

c.

Approximately 2 % of the fuel fails as a result of penetrating DNB limits based on the Modified Barnett CHF correlation.

d.

MDNBR for the loss of load event is bounded by other AOOs.

e.

MDNBR is bounded by the loss of flow event (15.3.1) 14 6

6

f.

About 0.1 % of the fuel rods in the core are calculated to fail as a result of penetrating DNB limits. The offsite doses that result from this event

g.

are a very small fraction of 1 O CFR 100 limits.

14.7 % of the fuel rods in the core are calculated to fail as a result of penetrating DNB limits. The offsite doses that result from this event are 44.3 rem (thyroid) and 1.0 rem (whole body). These doses are within the acceptance criteria for this event (75 rem for thyroid and 6.25 rem for whole body).

3.0 Disposition and Analysis of Plant Events EMF-92-178 Page 10 This section provides the results. of the disposition of events review and MDNBR analyses performed to support Cycle 11 operation. Event numbering and nomenclature are consistent with the SRP to facilitate review. This section provides information on the plant licensing basis including classification of plant conditions, classification of accident events by category, operating modes, initial conditions, neutronics data, core and fuel design parameters.

Listings of systems and components available for accident mitigation, trip setpoints, time delays and component capacities are also included. These data, together with the design parameters(20) and the event specific input data, represent a comprehensive summary of analysis inputs.

A system transient analysis for non-LOCA events was previously performed for Cycle 9(3). The changes introduced in Cycle 11 (i.e., increase in radial peaking limits and Cycle 11 core loading) affect only the event MDNBR and will not affect the system response to a non-LOCA transient event. Thus, the system thermal-hydraulic response for the transient analysis performed for Cycle 9 remains applicable to Cycle 11. The effect of increased radial peaking limits on MDNBR and LHR will be assessed for anticipated operational occurrences (AOO) for Cycle 11. The effect of the Cycle 11 changes on fuel failures and radiological consequences for the postulated accidents will be assessed. The Reference 14 large break LOCA was analyzed with radial peaking limits consistent with those for Cycle 11 and remains bounding.

15.0 Accident Analyses 15.0.1 Categorization of Plant Events EMF-92-178 Page 11 Plant events are placed in one of four categories. For Cycle 11, these categories are unchanged from previous analyses beginning with Cycle aC17). These categories, adopted by the American Nuclear Society (ANS), are described in Reference 2 as:

NORMAL OPERATION AND OPERATIONAL EVENTS (CONDITION I)

Events which are expected to occur frequently in the course of power operation, refueling, maintenance, or plant maneuvering.

FAULTS OF MODERATE FREQUENCY (CONDITION II)

Events which are expected to occur on a frequency of once per year during plant operation.

INFREQUENT FAUL TS (CONDITION Ill)

Events which are expected to occur once during the lifetime of the plant.

LIMITING FAUL TS (CONDITION IV)

Events which are not expected to occur but which are evaluated to demonstrate the adequacy of the design.

15.0.1.1 Acceptance Criteria NORMAL OPERATION AND OPERATIONAL EVENTS (CONDITION I)

This category describes the normal operational modes of the reactor. As such, events in this category must maintain margin between operating conditions and the plant setpoints.

The setpoints are established to assure maintenance of margin to design limits. The set of operating conditions, together with conservative allowances for uncertainties establish the set of initial conditions for the other event categories.

EMF-92-178

  • Page 12 FAULTS OF MODERATE FREQUENCY (CONDITION II) 1.

The pressures in reactor coolant and main steam systems should be less than 11 O %

of design values.

2.

The fuel cladding integrity should be maintained by ensuring that fuel design limits are not exceeded. That is, the minimum calculated departure from nucleate boiling ratio (DNBR) is not less than the applicable limits of the DNBR correlation being used.

3.

The radiological consequences should be less than 1 O CFR 20 guidelines.

4.

The event should not generate a more serious plant condition without other faults occurring independently.

INFREQUENT FAUL TS (CONDITION Ill).

1.
2.

The pressures in reactor coolant and main steam systems should be less than 11 O %

of design values.

A small fraction of fuel failures may occur, but these failures should not hinder the core coolability.

3.

The radiological consequences should be a small fraction of 1 O CFR 100 guidelines (generally < 1 O %).

4.

The event should not generate a limiting fault or result in the consequential loss of the reactor coolant or containment barriers.

LIMITING FAUL TS (CONDITION IV) 1.

Radiological consequences should not exceed 1 O CFR 100 guidelines.

2.

The event should not cause a consequential loss of the required functions of systems needed to cope with the reactor coolant and containment systems transients.

3.

Additional criteria to be satisfied by specific events are:

a.

LOCA - 1 O CFR 50.46 and Appendix K.

b.

Rod Ejection - Maximum deposited fuel enthalpy <280 cal/gm.

15.0.1.2 Accident Events By Category EMF-92-178 Page 13 Table 15.0.1-1 lists the accident category used for each event considered in this report.

This category is used in evaluating the acceptability of the results obtained from the analysis.

These are unchanged from previous analyses beginning with Cycle a(17).

EMF-92-178

  • Page 14 TABLE 15.0.1-1 ACCIDENT CATEGORY USED FOR EACH ANAL VZED EVENT SRP Event Designation Event Name 15.1 INCREASE IN HEAT REMOVAL BY THE SECONDARY SYSTEM 15.1.1 15.1.2 15.1.3 15.1.4 15.1.5 Decrease in Feedwater Temperature Increase in Feedwater Flow Increase in Steam Flow Inadvertent Opening of a Steam Generator Relief or Safety Valve Steam System Piping Failures Inside and Outside of Containment 15.2 DECREASE IN HEAT REMOVAL BY THE SECONDARY SYSTEM 15.2.1 15.2.2 15.2.3 15.2.4 15.2.5 15.2.6 15.2.7 15.2.8 Loss of External Load Turbine Trip Loss of Condenser Vacuum Closure of the Main Steam Isolation Valves (MSIV)

Steam Pressure Regulator Failure Loss of Nonemergency A.C. Power to the Station Auxiliaries Loss of Normal Feedwater Flow Feedwater System Pipe Breaks Inside and Outside Containment 15.3 DECREASE IN REACTOR COOLANT SYSTEM FLOW 15.3.1 15.3.2 15.3.3 15.3.4 Loss of Forced Reactor Coolant Flow Flow Controller Malfunction Reactor Coolant Pump Rotor Seizure Reactor Coolant Pump Shaft Break Category Ca>

Moderate (AOO)

Moderate (AOO)

Moderate (AOO)

Moderate (AOO)

Limiting Fault (PA)

Moderate (AOO)

Moderate (AOO)

Moderate (AOO)

Moderate (AOO)

Moderate (AOO)

Moderate (AOO)

Moderate (AOO)

Limiting Fault (PA)

Moderate (AOO)

Moderate (AOO)

Infrequent (PA)

Limiting Fault (PA)

EMF-92-178 Page 15 TABLE 15.0.1-1 ACCIDENT CATEGORY USED FOR EACH ANAL VZED EVENT, CONTINUED SAP Event Designation Event Name 15.4 REACTIVITY AND POWER DISTRIBUTION ANOMALIES 15.4.1 15.4.2 15.4.3 15.4.4 15.4.5 15.4.6 15.4.7 15.4.8 15.4.9 Uncontrolled Control Rod Bank Withdrawal from a Subcritical or Low Power Condition L.Jncontrolled Control Rod Bank Withdrawal at Power Operation Conditions Control Rod Misoperation

1)

Dropped Control Bank/Rod

2)

Dropped* Part-Length Control Rod

3)

Malpositioning of the Part-Length Control Group

4)

Statically Misaligned Control Rod/Bank

5)

Single Control Rod Withdrawal

6)

Core Barrel Failure Startup of an Inactive Loop Flow Controller Malfunction CVes MalfunctiQIJ that Results in a Decrease in the Boron Concentration in the Reactor Coolant Inadvertent Loading and Operation of a Fuel Assembly in an Improper Position Spectrum of Control Rod Ejection Accidents Spectrum of Rod Drop Accidents (BWR) 15.5 INCREASES IN REACTOR COOLANT SYSTEM INVENTORY 15.5.1 15.5.2 Inadvertent Operation of the.ECCS that Increases Reactor Coolant Inventory eves Malfunction that Increases Reactor Coolant Inventory Category< a>

Moderate (AOO)

Moderate (AOO)

Moderate (AOO)

Moderate (AOO)

Moderate (AOO)

Moderate (AOO)

Infrequent (PA)

Limiting Fault (PA)

Moderate (AOO)

Moderate (AOO)

Moderate (AOO)

Infrequent (PA)

Limiting Fault (PA)

Not Applicable Moderate (AOO)

Moderate (AOO)

EMF-92-178

  • Page 16 TABLE 15.0.1-1 ACCIDENT CATEGORY USED FOR EACH ANAL VZED EVENT, CONTINUED SAP Event Designation Event Name 15.6 DECREASES IN REACTOR COOLANT INVENTORY Category< a>

15.6.1 Inadvertent Opening of a PWR Pressurizer Moderate (AOO)

Pressure Relief Valve 15.6.2 Radiological Consequences of the Failure of Infrequent (PA)

Small Lines Carrying Primary Coolant Outside of Containment 15.6.3 Radiological Consequences of Steam Limiting Fault (PA)

Generator Tube Failure 15.6.4 Radiological Consequences of a Main Steam Limiting Fault (PA)

Line Failure Outside Containment 15.6.5 Loss of Coolant Accidents Resulting from a Limiting Fault (PA)

Spectrum of Postulated Piping Breaks Within the Reactor Coolant Pressure Boundary 15.7 RADIOACTIVE RELEASES FROM A SUBSYSTEM OR COMPONENT 15.7.1 15.7.2 15.7.3 15.7.4 15.7.5 Waste Gas System Failure Radioactive Liquid Waste System Leak or Failure (Release to Atmosphere)

Postulated Radioactive Releases Due to Liquid-Containing Tank Failures Radiological Consequences of Fuel Handling Accident Spent Fuel Cask Drop Accidents

a.

Anticipated Operational Occurrence (AOO)

Postulated Accident (PA)

Note (b)

Note (b)

Infrequent (PA)

Limiting Fault (PA)

Infrequent (PA)

b.

This event has been deleted from the SAP but is part of the Palisades licensing basis.

15.0.2 Plant Characteristics and Initial Conditions EMF-92-178 Page 17 Eight operational modes have been considered in the disposition and analyses. These are given in Table 15.0.2-1. These operational modes have been considered in establishing the subevents associated with each event initiator. A set of initial conditions is established for the events analyzed that is consistent with the conditions for each mode of operation. The modes of plant operation are unchanged for Cycle 11.

The nominal plant rated operating conditions are presented in Table 15.0.2-2 and principal fuel design characteristics in Table 15.0.2-3. The following uncertainties were used in the Reference 3 accident analysis and are applicable to Cycle 11 :

Core Power Primary Coolant Temperature Primary Coolant Pressure Primary Coolant Flow

+/-2%

+/- 5 °F

+/- 50 psi

+/-3%

The maximum PCS mass flow rate supported by this analysis is defined by that assumed in the main steam line break analysis (i.e., 145.9 Mlbm/hr at 554 °F and 2060 psia)(3).

This is equivalent to 150.3 Mlbm/hr at 532 °F and 2060 psia.

TABLE 15.0.2-1 PLANT OPERATIONAL MODES Mode(a)

Reactivity Power(b)

Rated Power (1)

Critical 100 % (2530 MWt)

Power Operation (2)

Critical

~2%

Reactor Critical (3)

Critical

~ 104 %

Hot Standby (4)

Any Withdrawn Rod 104 % to 2 %

Hot Shutdown (5)

Shutdown Margin

< 104 %

~2% Ap Refueling Shutdown Shutdown margin of at 0

Condition (6) least 5 % A p with all control rods withdrawn Cold Shutdown keff s.98 with all Condition (7) control rods in the core and the highest worth control rod fully withdrawn Refueling Operation Any operation (8) involving movement of core components when the vessel head is unbolted or removed

a.

Mode numbers are given in parenthesis.

b.

Does not include decay heat.

EMF-92-178

  • Page 18 Average Core Temperature

~ 525 °F

~ 525 °F

~ 525 °F

> 525 °F

> 525 °F

!:: 210 °F s 210 °F

I.

EMF-92-178 Page 19 TABLE 15.0.2-2 NOMINAL PLANT OPERATING CONDITIONS Core Thermal Power (MWt) 2530 Pump Thermal Power, total (MWt) 15 System Pressure (psia) 2060 Vessel Coolant Flow Rate (Mlbm/hr) 138.6(a)

Core Coolant Flow Rate (Mlbm/hr) 134.4(b)

Core Inlet Coolant Temperature (°F) 543.65 Steam Generator Pressure (psia) 722 Steam Flow Rate (Mlbm/hr) 10.97 Feedwater Temperature (°F) 435 Number of Active Tubes per Steam 6986(a)

Generator Total Number of Assemblies 204

a.

Reflects 15.0 % average steam generator tube plugging.

b.

Reflects a 3 % bypass flow.

.r.

EMF-92-178 Page 20 TABLE 15.0.2-3 NOMINAL RELOAD 0 FUEL DESIGN PARAMETERS Total Number of Reload 0 Fuel Assemblies Fuel Assembly Design Type Fueled Rods per Assembly Instrument Tubes per Assembly Guide Bars per Assembly Assembly Pitch (inches)

Rod Pitch (inches)

Fuel Pellet Outside Diameter (inches)

Clad Inside Diameter (inches)

Clad Outside Diameter (inches)

Active Fuel Length (inches)

Number of Spacers 60 15 x 15 216.

1 8

8.485 0.550 0.3510 0.358 0.417 131.8 10

15.0.3 Power Distribution EMF-92-178 Page 21 The radial and axial power peaking factors used in the analysis are presented in Table 15.0.3-1. The analyses for the inlet temperature LCO and for the TM/LP trip utilize axial power distributions and associated ASls. The axial power distributions are generated from a three-dimensional core physics model. Figure 15.0.3-1 shows the DNB limiting axial shape for 100

% power events. This axial shape has an axial shape index (ASI) of -0.143 and represents a bounding full power hot channel shape, associated excore ASI and full power control rod insertion limits. In this context, ASI is defined as:

Plower corresponds to the power generated in the lower half of the core and Pupper corresponds to the power generated in the upper half of the core.

MDNBR occurs on an interior pin of a Reload 0 assembly.

The Technical Specification(7) Limiting Conditions of Operation (LCO) ensure that the power distribution is maintained within these limits during normal operation. However, some events analyzed result in transient redistribution of the radial power peaking factors.

Transient radial power redistribution is treated as described in Section 15.4.3.2 of Reference 2.

TABLE 15.0.3-1 CORE POWER DISTRIBUTION Radial Peaking Factor:

208 fuel rods/assembly 216 fuel rods/assembly Reload M(a)

Reload N(b)

Reload 0 Axial Peaking Factor Engineering Tolerance Uncertainty Fraction of Power Deposited in the Fuel Assembly (Fr~

1.48 1.57 1.66 1.76 See Figure 15.0.3-1 1.03 0.974

a.

Reference 3 addresses the radial peaking limits for Reload M.

b.

Reference 21 addresses the radial peaking limits for Reload N.

EMF-92-178

  • Page 22 Peak Rod (F r:1 1.92 1.92 1.92 2.04

(_

Cl) :s 0

a..

0

  • .J x a:

"'O Cl)

N

  • .J 0 e

(_

0 z 1.1 1.2 1.0 0.8 0.6 0.1 0.2 Bollom EMF-92-178 Page 23 Top o.o.......... _...._._........_...................... _._................_..___._._............._...__........... _._...._......_......... _.__._......._...................... _._..............._.......... _.__._....._......_........

o.o 0.1 0.2 0.3 0.1 0.5 0.6 0.7 0.8 0.9 1.0 f raclLon of AclLve f ueL HeLghl FIGURE 15.0.3-1 LIMITING AXIAL POWER SHAPE (ASI = -0.143)

EMF-92-178

  • Page 24 15.0.4 Range of Plant Operating Parameters and States Table 15.0.4-1 presents the range of key plant operating parameters considered in the Reference 3 transient analysis. A broader range of power, core inlet temperature, and primary pressure is considered in establishing the trip setpoints verified by the analysis results presented in this document. These are unchanged for Cycle 11.

EMF-92-178 Page 25 TABLE 15.0.4-1 RANGE OF KEY INITIAL CONDITION OPERATING PARAMETERS Core thermal power Inlet coolant temperature (Power operation)

Primary coolant system pressure Pressurizer water level Feedwater flow and temperature 1.02 x 2530 MWt Subcritical to 2580.6 MWt(a)

Tinlet LCO +/- 5 oF 2060 psia +/- 50 psi Programmed +/- 5 % of level span Range consistent with power level

15.0.5 Reactivity Coefficients Used in the Safety Analysis EMF-92-178

  • Page 26 Table 15.0.5-1 presents the reactivity coefficients used in the reference trans,ient analy-sis(3). The analysis conservativ~ly supports the Technical Specification moderator temperature coefficient (MTC) of ~ +0.5 x 104 ll. p/°F. The nominal full power Cycle 11 burn up is 12,850 MWd/MTU. The safety analysis is, however, applicable to a full power end-of-Cycle 11 exposure of 13,440 MWd/MTU and accounts for a power-temperature coastdown to 70 % of rated power.

TABLE 15.0.5-1 REACTIVITY PARAMETERS BOC Item Bounding Moderator Temperature Coefficient, 1 o4 ll. p/°F 0.5 Doppler Temperature Coefficient, 1 o-5 ll. p/°F

-1.09 Moderator Pressure Coefficient, 10-6 ll. p/psi

-1.0 Delayed Neutron Fraction 0.0075 Effective Neutron Lifetime, 1 o-6 seconds 41.9 u238 Atoms Consumed per Total Atoms Fissioned 0.54 EMF-92-178 Page 27 EOC Bounding

-3.5

-1.76 7.0 0.0045 19.9 0.70

EMF-92-178

  • Page 28 15.0.6 Scram Insertion Characteristics The insertion worth of 2.0 % Ii p and a control rod drop time of 2.5 seconds (to 90 %

insertion) have been supported by the analysis for Cycle 11. Figure 15.0.6-1 presents the negative insertion used in the reference transient analysis(3) for reactor trip. The insertion worth includes the most reactive rod stuck out.

n (J

0 GI

~

E 0

(..

(J (f)

"O GI N

~

0 E

(..

0 z a.a 0.6 0.4 0.2 EMF-92-178 Page 29 o.ol_...._..___.__..J..._......... :::c::::=:::::L::::=__.____i__.__...__.,--1____.~,__...._.t..__,__.__._J o.o 0.5 1.0 1.5 2.0 2.5 3.0 TLme ofler Scrom, seconds FIGURE 15.0.6-1 INTEGRATED SCRAM WORTH WITH MOST REACTIVE ROD STUCK OUT

15.0.7 Reactor Protection System Trip Setpoints and Time Delays EMF-92-178 Page 30 Table 15.0.7-1 presents the trip setpoints, uncertainties, and time delays used in the Reference 3 analysis. The Reference 3 setpoint and transient analysis is applicable to Cycle

11. The setpoints used are discussed in the section describing each transient in Reference
3.

An inlet temperature limiting condition of operation, Tinlet LCO, and thermal margin/low pressure (TM/LP) trip were developed for Cycle 9. The analysis performed herein confirms their continued applicability to the Cycle 11 core.

Their development, unchanged from Reference 3, and the results of the Cycle 11 verification analyses are presented in the following sections.

The Tinlet LCO described in Section 15.0.7.1 was used to develop the initial conditions used in the reference transient analyses. The TM/LP trip described in Section 15.0.7.2 was included in the reference transient simulations.

15.0.7.1 Inlet Temperature Limiting Condition of Operation The Tinlet LCO provides protection against penetrating DNB during limiting AOO transients from full power operation. The most limiting AOO transient that does not produce a reactor trip is the inadvertent drop of a full length control assembly. Therefore, the Tinlet LCO must provide DNB protection for this transient assuming a return to full power with enhanced peaking due to the anomalous control assembly insertion pattern.

The Tinlet LCO was developed in Reference 3 using the XCOBRA-lllC computer code(13) with augmented radial peaking. The XCOBRA-lllC calculations were run to determine the inlet temperature which resulted in a DNB equal to the 95/95 safety limit for a range of pressurizer pressures, core power levels and primary coolant system flow rates. These calculations were performed over a range of ASls from -0.63 to +0.63.

The results of the above analysis correspond to plant measured values of pressurizer pressure, primary coolant system flow rate and the inlet temperature and includes a 2 % power and a +/- 0.06 ASI measurement uncertainty. These results must, therefore, be biased to

EMF-92-178 Page 31 account for both measurement uncertainty and variations due to the control assembly drop transient. The Cycle 11 verification analysis included the same uncertainties and transient allowances as in Reference 3, namely: (1) a +/- 50 psia pressure measurement uncertainty, (2) a +/- 7 °F inlet temperature uncertainty (Reference 17, +/- 5 °F tilt allowance +/- 2 °F measurement uncertainty), (3) a +/- 6 % to the flow rate (+/- 3 % bypass flow and +/- 3 % measurement uncertainty) and, (4) a -20 psia transient pressure bias.

Accounting for measurement uncertainties and transient biases, the Tinlet LCO equation is as follows:

1in1et ~ 542.99 + 0.0580x(P - 2060) + 1.0x1 o-5x(P - 2060)2

+ 1.125x(W - 138) - 0.0205x(W - 138)2 From Reference 3, the above equation is applicable for pressurizer pressures (P) between 1800 and 2200 psia and primary coolant system (PCS) mass flow rates CW) between 100 and 150 Mlbm/hr.

For primary loop flow rates greater than 150 Mlbm/hr, the inl.et temperature is limited to the Tinlet LCO value at 150 Mlbm/hr. The Tinlet LCO is applicable for measured ASI in the range from +0.40 to -0.08 and can be c,ompared to an average cold leg temperature for each of the four loops. The applicability of the Tinlet LCO equation was extended to a measured ASI of -0.30 at 70 % rated power and -0.55 at 25 % rated power. The applicable range of the Tinlet LCO is shown in Figure 15. 0. 7-1.

Calculations were performed for Cycle 11 using the XCOBRA-lllC computer code and a conservative peaking augmentation factor to demonstrate the continued applicability of the above Tinlet LCO equation. The XCOBRA-lllC calculations were run to demonstrate that the inlet temperature allowed by the Tinlet LCO results in a DNBR greater than the 95/95 limit for the ANFP correlation over a range of pressurizer pressures, primary coolant system flow rates, axial shape indices and core power levels.

15.0.7.2 Thermal Margin/Low Pressure CTM/LP) Trip EMF-92-178 Page 32 The function of the TM/LP trip is to protect the core against slow heatup and depressurization transient events. In order to perform this function, the TM/LP trip must initiate a scram signal prior to exceeding the specified acceptable fuel design limits (SAFDLs) on departure from nucleate boiling (DNB) or before the average core exit temperature exceeds the saturation temperature. The SAFDL ensures that there is, no damage to the fuel,rods and the limit on core exit saturation ensures meaningful thermal power measurements.

The NSSS is protected against penetrating DNB during rapid power, flow, and pressure transient events by the variable high power (VHP) trip, the low flow trip and the high pressurizer pressure trip, respectively. For slow transient events, however, it is possible that either the SAFDL on DNB or hot leg saturation could be reached prior to activating these trip setpoints. These slow transients generally involve a slow heatup of the primary coolant system caused by: (1) a power mismatch between the primary and secondary systems or, (2) a slow depressurization of the primary system with or without a slow power ramp. Transient events that exhibit these characteristics and must, therefore, be protected by the TM/LP include an uncontrolled rod withdrawal, an inadvertent boron dilution, an excess load, a loss of feedwater or a PCS depressurization. The TM/LP trip works in conjunction with the other trips and the LCO on control rod group position, radial peaking and primary coolant flow.

The functional form for the Palisades TM/LP trip is:

PVlll' = a.xDiJNs + pxTca1 + y where: P var is the low pressure trip limit; a., p, and y are constants to be determined; T cal is the highest measured cold leg temperature adjusted for possible coolant stratification in the cold leg; and, QDNB is a function representing axial and radial power peaking effects. The adjusted cold leg temperature T cal is calculated from:

EMF-92-178 Page 33 where B is the measured 4 T power, Kc is a flow stratification factor, and Tin is the highest measured cold leg temperature in each steam generator. For NSSS like Palisades, which have the cold leg temperature sensors located downstream of the primary coolant pumps, there is sufficient mixing so that Kc = 0.0 and T cal equals Tin*

The QDNB function is represented as:

where QA is a function representing the variation in power versus axial shape at constant DNB, and OR1 is a function representing the variation in power with radial peaking and/or hot leg saturation.

15.0.7.2.1 TM/LP Uncertainties In setting the TM/LP trip it is necessary to conservatively account for the uncertainties in the measured parameters used to determine the trip. These uncertainties result not only from the inability of the instrumentation to exactly measure the value of a parameter, but also from the fact that the changes in the parameters being measured may actually lag behind the event of interest. Therefore, in any transient uncertainty analysis, both static and transient effects must be considered.

The input parameters for the TM/LP for which uncertainties must be determined and accounted for in the trip development are inlet temperature, core power, pressure and axial shape index. The uncertainty applied to the pressure in this analysis is 165 psiC18). This uncertainty was developed to account for most of the uncertainties in the TM/LP. Included in

EMF-92-178 Page 34 this 165 psi are: instrument drift in both power and inlet temperature, calorimetric power measurement, inlet temperature measurement and, primary pressure measurement.

The uncertainties in these parameters will, consequently, not be treated separately in this analysis.

An additional uncertainty, not accounted for in the 165 psi*, is associated with the inlet temperature. This uncertainty accounts for the lag time in the RTDs (12 seconds) and primary coolant system transit times. These times were converted to temperature uncertainties through the use of a typical temperature ramp for a slow rod withdrawal. The inlet temperature uncertainty for these time delays was found to be bounded by 1.5°F.

Also, uncertainties used in-this analysis include a 3 % uncertainty to account for manufacturing tolerances and a 6 % uncertainty in PCS flow to account for 3 % core bypass flow and 3 % measurement uncertainty.

The final uncertainty is in the measured ASI used in the TM/LP. This uncertainty was taken to be +/- 0.06 consistent with the ASI uncertainty assumed for other Combustion Engineering plants. The uncertainties applied in the development of the TM/LP in Reference 3 are summarized in Table 15.0.7-2.

15.0.7.2.2 TM/LP Development In the actual development of the TM/LP in Reference 3, a definite step-by-step procedure is followed. First, the axial shape function QA is developed. This is followed by the determination of the radial peaking function QR1. Finally, the coefficients a, p, and y are derived. Throughout this development the various uncertainties are applied to ensure that the final TM/LP function is conservative.

The first function derived, QA, is the axial shape function and corrects the TM/LP for variations in power with axial shape index (ASI) at a constant DNBR valu*e. This function was generated by finding the limiting axial shapes from 756 axial shapes. The limiting axial shapes cover an ASI range from -0.63 to +0,63. The limiting axial shapes were used in the XCOBRA-

EMF-92-178 Page 35 lllC model to determine the power level required to reach a DNBR equivalent to the correlation safety limit. These results are conservatively fitted as a function of ASI with three straight lines with maximized slopes. The QA function is derived by normalizing the straight line functions to the peak power and inverting the result. The derived QA function is plotted in Figure 15.0.7-

2. Note that this QA function has been developed to cover the full range of the possible ASl's.

The radial peaking function, QR1, accounts for the changes in slope of the core protection limit lines with radial peaking and hot leg saturation.. The core protection limits are parallel equally spaced lines representing the variation in the maximum allowed inlet temperature with power and pressure. These lines are composed of two limiting portions: the first, which dominates at low powers, is the inlet temperature which produces saturation in the hot leg; and, the second is the inlet temperature which produces the minimum allowed DNBR.

The core protection limits for an ASI of +0.200 (QA = 1.00) are given in Figure 15.0.7-3.

Adjustments were made to the trip coefficients to ensure that the trip conservatively bounds the core protection limits. The TM/LP trip equation developed in Reference 3 is as follows:

Pv* = 2012x(OA)x(OR1) + 17.0x(Ji,J - 9493 QR1 = 0.412x(Q) + 0.588 for Q ~ 1.0 QR1 = Q for Q > 1.0 QA = -0.720x(AS~ + 1.028 for -0.628 ~AS/< -0.100

QA = -0.333x(AS/) + 1.067 QA = +0.375x(AS/) + 0.925 for -0.100 ~ AS/ < +0.200 for +0.200 ~ AS/~ +0.565 EMF-92-178 Page 36 P var is defined as the low pressurizer pressure trip limit, QA is the axial shape function, QR1 is the radial peaking function, Tin is the highest measured cold leg temperature, Q is the fraction of rated power and ASI is the axial shape index. From Reference 3, this TM/LP equation is applicable over a pressure range from 1700 psia to 2300 psia and to a minimum measured HZP primary coolant flow rate of 140.7 Mlbm/hr. Figure 15.0.7-2 shows the QA function. The core protection limits for an ASI of +0.200 are shown in Figure 15.0.7-3.

The TM/LP trip function was verified for Cycle 11 by first determining a set of limiting axial shapes. The limiting axial shapes covered the ASI range defined by the Tinlet LCO. The limiting axial shapes were used in the XCOBRA-lllC model to ensure that the MDNBR for conditions allowed by the TM/LP trip function is greater than the ANFP correlation 95/95 limit.

Thus, the TM/LP trip was verified to be applicable over the possible range of axial shapes for Cycle 11.

15.0.7.3 Variable High Power NHP) Trip Reference 3 (Section 15.0.7.3) discussed the VHP trip uncertainties employed in the reference transient analyses. The following discussion reiterates that in Reference 3.

From Table 15.0.7-1, the VHP trip uncertainty is given as +/- 8.5 %.

A +/- 3.0 %

allowance that accounts for potential differences between the 11. T and neutron flux power measurements is included. The reactor protection system (RPS) circuitry uses an auctioneered high value of 4 T and neutron flux power to set the VHP trip setpoint. If the neutron flux power is 3.0 % less than the 4 T_power, the VHP trip setpoint is based on the 4 T power. For fast'

EMF-92-178 Page 37 transients in which the /1 T power response lags behind the neutron power, a 3.0 % /1 T-neutron flux power difference can delay the occurrence of a VHP trip. Thus, for transient events that are protected by the VHP trip, an uncertainty of +/- 8.5 % is used..

For "slow" transients, however, the plant is protected by either the VHP or TM/LP trip.

During these events, the thermal lags associated with the calculation of /1 T power are less than the overall time of the event, i.e., /1 T power is able to track the neutron flux power. Thus, a 3.0

% difference in fl. T-neutron flux power will not impact the time of trip since the trip setpoint is based on the higher of /1 T or neutron power. The effective VHP trip uncertainty under these conditions is +/- 5.5 %.

  • w.

EMF-92-178 Page 38 TABLE 15.0.7-1 TRIP SETPOINTS FOR OPERATION AT 2530 MWT Trip Setpoint Uncertaintv Dela~ Time Low Reactor Coolant Flow 95 % of rated four

+/- 2.0%

0.6 sec pump flow High Pressurizer Pressure 2255 psia

+/- 22 psi 0.6 Low Pressurizer Pressure 1750 psia

_+/- 22 psi 0.6'l Low Steam Generator Pressure 500 psia

+/- 22 psi 0.6 Low Steam Generator Level(a) 6 feet

+/- 10 inches 0.6 Thermal Margin/Low Pressure(b) p = f(T H,Tc)

  • +/- 165 psi 0.6 Variable High Power 106.5 % maximum

+/- 8.5%

OA 30.0 % minimum 15.0 % above thermal power

a.

Below operating level.

b.

The thermal margin trip setpoint is a functional pressurizer pressure (P} setpoint,

  • varying as function of the maximum cold leg temperature (Tc), the measured power, and the measured axial shape index.

TABLE 15.0.7-2 TM/LP UNCERTAINTIES Instrument Drift (Power, Tinlet)

Calorimetric Power Tinlet measurement Pressure Measurement RTD Measurement Engineering Tolerances Primary Coolant Flow Inlet Temperature Time Delay Axial Shape Index EMF-92-178 Page 39

+/- 165 psi

+/-3%

+/-6%

1.5 °F(a)

+/- 0.06

a.

Inlet temperature time delay was applied as an equivalent temperature bias.

~

3:

l::

0 l"'l I.()

N

(..

CJ)

JI 0

a...

-0 CJ)

~

0 0:::

(o..

0 c

0

  • ..J

~

0 0

(..

t...

I.IS Unacceploble Operali..ons 1.00 0.85 0.70 0.55 Accept.able 0.10 Operoli.ons Break Poi.nls 1 * -0.550, 0.25

2. -0.300, 0.70
3. -0.080, 1.00
4. -0.080, 1.065
5. +0.400, 1.065
6. +0.400, -0.25 EMF-92-178
  • Page 40 5

6 0.25

.__~_._~.__......___..~.._----'~...__.___,~.......___._~.___.__..~.___.___..~..__.___,~......__.

-0.6

-0.1

-0.2 o.o 0.2 0.1 0.6 Axi.ol Shope [ndex FIGURE 15.0.7-1 TINLET LIMITING CONDITION OF OPERATION

a:

0 1.5 l.i 1.3 1.2

1.
2.
3.
4.

1.1 Break Poi..nt.s

-0.628, 1.48

-0.100, 1. 10 0.200, 1.00 0.565, 1. 14 EMF-92-178 Page 41 1.0.._.._..._......._........_.......... _.__.__..__.____..__.__.._..._.......__......_........___._""""""'_.___.__..__.__.._....__.......__........___.___,

-0.7

-0.5

-0.3

-O. I 0.1 0.3 0.5 0.7 Axt.al Shape Index FIGURE 15.0.7-2 AXIAL SHAPE FUNCTION FOR TM/LP TRIP

t.....

(j)

Q)

Q)

L en Q) c:::l Q)

L

J 0

L Q) a..

E Q)

I-Q)

~

c 620.0 600.0 580.0 560.0 510.0 520.0 EMF-92-178 Page 42 2300 psL.

2200 psLa 2100 psLa 2000 psLa 1900 psLa 1800 psLa 1700 psLa 500.0

.._...__.__._~.._..._....... ___.~..__....__.___.~..__....__.___.~.._........ _.___...___,__.__._~.__.

o.o 0.2 0.1 o.s o.e 1.0 1.2 froctLon of Roted Pover FIGURE 15.0.7-3 CORE PROTECTION LIMITS FOR TM/LP TRIP (ASI = +0.200)

15.0.8 Component Capacities and Setpoints EMF-92-178 Page 43 Table 15.0.8-1 presents the component setpoints and capacities supported by this analysis. These are unchanged from the Reference 3 analysis.

TABLE 15.0.8-1 COMPONENT CAPACITIES AND SETPOiNTS

Response

Time Pressurizer Safety Valves (3)

Pressurizer Relief Valves (2) 2 sec Steam Line Relief Valves (24)

Turbine Stop and Control Valves 0.1 sec Steam Dump Valves and Turbine 3.0 sec Bypass Pressurizer Backup Heaters Pressurizer Proportional Heaters Pressurizer Sprays Letdown Orifice Valves eves Makeup System Normal Feedwater system 20.5 sec Nominal Setpoint 2500 psia 2540 psia 2580 psia 2400 psia Group A at 1000 psia Group B at 1020 psia Group C at 1040 psia Turbine trip then T avg program Always on Full on-201 o psia Full off-2060 psia Full on-211 O psia Full off-2060 psia Level controller Level controller Feedwater controller Setpoint Uncertainty 75 psia 50 psia 3%

50 psia 50 psia 50 psia 50 psia Total Capacity 191 lbm/sec 319 lbm/sec 3244 lbm/sec at 1000 psia 1173 lbm/sec at 770 psia 1350 kW 150 kW 29.4 lbm/sec (1.5 gpm continuous flow) 12.6 lbm/sec 18.5 lbm/sec 3321.4 lbm/sec

~ -------

m s::

-"tl '"Tl fl)

I co <O (l) I\\)

I

.i::.""

.i:o. (X)

  • EMF-92-178 Page 45 15.0.9 Plant Systems and Components Available for Mitigation of Accident Effects Table 15.0.9-1 is a summary of trip functions, engineered safety features, and other equipment available for mitigation of accident effects. These are listed for all Chapter 15 SRP
  • events and are unchanged from the Reference 3 analysis.

SRP Designation 15.1 15.1.1 15.1.2 15.1.3 15.1.4 15.1.5 TABLE 15.0.9-1 OVERVIEW OF PLANT SYSTEMS AND EQUIPMENT AVAILABLE FOR TRANSIENT AND ACCIDENT CONDITIONS Event INCREASE IN HEAT REMOVAL BY THE SECONDARY SYSTEM Feedwater System Malfunctions Increase in Steam Flow Inadvertent Opening of a Steam Generator Relief or Safety Valve Steam System Piping Failure Reactor Trip Functions VHP trip TM/LP Trip Low Steam Generator Pressure Trip Safety Injection Actuation Signal Low Steam Generator Pressure Trip TM/LP Trip VHP trip Safety Injection Actuation Signal Low Steam Generator Pressure Trip TM/LP Trip VHP trip Safety Injection Actuation Signal Low Steam Generator Pressure Trip TM/LP Trip VHP trip Safety Injection Actuation Signal High Containment Pressure Other Signals/Equipment Steam Generator Water Level Signals Feedwater Isolation Valves Main Steam Line Isolation Valves Turbine Trip on Reactor Trip Chemical and Volume Control System (CVCS)

Steam Generator Water Level Signals Main Steam Line Isolation Valves Turbine Trip on Reactor Trip Atmospheric Steam Dump Controller Steam Bypass to Condenser Controller Auxiliary Feedwater System eves Steam Generator Water Level Signals Main Steam Line Isolation Valves.

Turbine Trip on Reactor Trip Atmospheric Steam Dump Controller Steam Bypass to Condenser Controller Auxiliary Feedwater System eves Steam Generator Water Level Signals Main Steam Line Isolation Valves Turbine Trip on Reactor Trip Atmospheric Steam Dump Controller Steam Bypass to Condenser Controller Auxiliary Feedwater System Containment Spray Containment Isolation Contair:m'lent Air Coolers eves m

s::

""'O Tl

!l)

I co <O

<t> I}>

.i:i.""""'

m m

SAP Designation 15.3 15.3.1 15.3.3 15.3.4 15.4 15.4.1 15.4.2 TABLE 15.0.9-1 OVERVIEW OF PLANT SYSTEMS AND EQUIPMENT AVAILABLE FOR TRANSIENT AND ACCIDENT CONDITIONS, CONTINUED Event Reactor Trie Functions Other SignalslEgulement DECREASE IN REACTOR COOLANT SYSTEM FLOW RATE Loss of Forced Reactor Coolant Low Reactor Coolant Flow Trip Atmospheric Steam Dump Controller Flow TM/LP Trip Steam Bypass to* Condenser Controller High Pressurizer Pressure Trip Steam Generator Safety Valves Pressurizer Safety Valves Reactor Coolant Pump Rotor Low Reactor Coolant Flow Trip Atmospheric Steam Dump Controller Seizure/Shaft Break High Pressurizer Pressure Trip Steam Bypass to Condenser Controller Steam Generator Safety Valves Pressurizer Safety Valves REACTIVITY AND POWER DISTRIBUTION ANOMALIES Uncontrolled Control Rod Bank TM/LP Trip Non-safety Grade High Rate-of-Change Withdrawal from a Subcritical or Low VHP trip of Power Trip Power Startup Condition High Pressurizer Pressure Trip High Rate-of-Change of Power Alarms, which initiate Rod Withdrawal Prohibit Action Uncontrolled Control Rod Bank VHP trip Pressurizer Safety Valves Withdrawal at Power Operation TM/LP Trip Steam Generator Safety Valves Conditions High Pressurizer Pressure Trip Pressurizer Spray and Level Control Control Rod and Bank Deviation Alarms

SAP Designation 15.4.3 15.4.4 15.4.6 15.4.7 15.4.8 TABLE 15.0.9-1 OVERVIEW OF PLANT SYSTEMS AND EQUIPMENT AVAILABLE FOR TRANSIENT AND ACCIDENT CONDITIONS, CONTINUEO Event Control Rod Misoperation Startup of an Inactive Loop Chemical Volume and Control System (CVCS) Malfunction that Results in a Decrease in the Boron Concentration In the Reactor Coolant Inadvertent Loading and Operation of a Fuel Assembly in an Improper Position Spectrum of Control Rod Ejection Accidents Reactor Trip Functions TM/LP Trip Low Steam Generator Water Level Trip Safety Injection Actuation Signal VHP trip TM/LP Trip VHP trip TM/LP Trip High Pressurizer Pressure Trip Technical Specification measurement requirements and administrative procedures preclude occurrence VHP trip TM/LP Trip Long Term, Safety Injection Actuation Signal

. )

Other Signals/Equipment Pressurizer Safety Valves Steam Generator Safety Valves Pressurizer Spray and Level Control Control Rod and Bank Deviation Alarms eves*

Administrative Procedures for Startup of an Idle Pump.

Plant Operation with less than all four primary coolant pumps is not permitted by Technical Specifications except for very short periods of time and at reduced power levels (Tech Spec Table 2.3.1).

Non-safety Grade High Rate-of-Change of Power Trip Administrative Procedures Sufficient Operator Response Time Non-safety Grade High Rate-of-Change of Power Trip eves

SRP Designation 15.5 15.5.1 15.5.2 15.6 15.6.1 15.6.3 15.6.5 TABLE 15.0.9-1 OVERVIEW OF PLANT SYSTEMS AND EQUIPMENT AVAILABLE FOR TRANSIENT AND ACCIDENT CONDITIONS, CONTINUED Event INCREASE IN REACTOR COOLANT INVENTORY Inadvertent Operation of the ECCS/CVCS Malfunction that Increases Reactor Coolant Inventory DECREASE IN REACTOR COOLANT INVENTORY Inadvertent Opening of a PWR Pressurizer Pressure Relief Valve Steam Generator Tube Failure Loss of Coolant Accidents Resulting from a Spectrum of Postulated Piping Breaks within the Reactor Coolant Pressure Boundary Reactor Trip Functions VHP trip TM/LP Trip High Pressurizer Pressure Trip TM/LP Trip Safety Injection Actuation Signal TM/LP Trip Safety Injection Actuation Signal No credit taken for a reactor trip by the RPS due to the rapid depletion of the moderator which shuts down the reactor core almost immediately, followed by ECCS injection which contains sufficient boron to maintain the reactor core in a subcritical configuration.

Other Signals/Equipment Non-safety Grade High Rate-of-Change of Power Trip Pressurizer Safety Valves Overpressurlzatlon Mitigation System (Modes 6-8)

Safety Injection System Pressurizer Heaters eves Steam Generator Safety Valves Main Steam Line Isolation Valves Atmospheric Steam Dump Controller Steam Bypass to Condenser Controller Auxiliary Feedwater System eves ECCS Auxiliary Feedwater System Containment Isolation Containment Spray and Air Cooler m

s:

-a 'Tl Q)

I co <D CD l')-l 01 "'-I 0

CX>

  • 15.0.10 Effects of Mixed Assembly Types and Fuel Rod Bowing EMF-92-178 Page 51 The Cycle 11 core contains only fuel assemblies manufactured by SPC. Beginning with Reload M, High Thermal Performance (HTP) spacers have been utilized on SPC fuel for Palisades. Bi-metallic grid spacers are used in the sixteen Reload I assemblies with hafnium inserts that are being used for shielding purposes in low powered peripheral locations. Due to a low radial leakage core loading pattern for Cycle 11, the highest powered assemblies are centrally located where the core is composed solely of HTP spacer fuel. Since the DNBR limiting assemblies are centrally located, the 2 % mixed core MDNBR penalty(S) is not necessary. For assemblies with HTP spacers, DNBRs are calculated with the ANFP critical heat flux correlation(9* 1°) with a 95/95 safety limit of 1.154.

The effects of rod bow on limiting DNB and heat flux peaking were considered.

Reference 11 concludes that due to the short distances between spacers, the 15 x 15 design does not exhibit fuel rod bow of any significance to plant operating margins. Therefore, no penalty is applied due to rod bow effects.

15.0.11 Plant Licensing Basis and Single Failure Criteria EMF-92-178

  • Page 52 The licensing basis for Palisades is as stated in the Final Safety Analysis Report(6). The event scenarios depend on single failure criteria established by the plant licensing basis.

Examination of the Palisades licensing basis yields the following single failure criteria:

(1)

The RPS is designed with redundancy and independence to assure that no single failure or removal from service of any component or channel of a system will result in the loss of the protection function.

(2)

Each Engineered Safety Feature (ESF) is designed to perform its intended safety function assuming a failure of a single active component.

  • (3)

The onsite power system and the offsite power system are designed such that each shall independently be capable of providing power for the ESF assuming a failure of a single active component in either power system.

The* safety analysis is structured to demonstrate that the plant systems design satisfies these single failure criteria. The following assumptions result:

-(1)

The ESF required to function in an event are assumed to suffer a worst single failure of an active component.

(2)

Reactor trips occur at the specified setpoint within the specified delay time assuming a worst single active failure.

(3)

The following postulated accidents are considered assuming a concurrent loss of offsite power: main steam line break, contro_I rod ejection, steam generator tube rupture, and LOCA.

(4)

The loss of normal feedwater, an anticipated operational occurrence, is analyzed assuming a concurrent loss of offsite power.

The requirements of 1 O CFR 50, Appendix A, Criteria 1 o, 20, 25 and 29 require that the design and operation of the plant and the reactor protective system assure that the SAFDLs not be exceeded during Anticipated Operational Occurrences (AOOs). As per the definition

EMF-92-178 Page 53 of the plant and include but are not limited to loss of power to all recirculation pumps, tripping of the turbine generator set, isolation of the main condenser, and loss of all offsite power".

The SAFDLs are that: (1) the fuel shall not experience centerline melt, i.e., linear heat rate, LHR, to be less than 21 kW/ft, and (2) the DNBR shall have a minimum allowable limit such that there is a 95 % probability with a 95 % confidence interval that DNB has not occurred, i.e.,

DNBR to be greater than the correlation limit for ANFP.

EMF-92-178 Page 54 The following sections, numbered according to the SAP, provide a discussion of the disposition. of events review and MDNBR and peak LHR analyses performed to support Cycle 11 operation.

15.1 Increase in Heat Removal by the Secondary System The magnitude of the decrease in feedwater temperature, increase in feedwater flow rate, increase in steam flow and inadvertent opening of a steam generator relief/safety valve for Events 15.1.1, 15.1.2, 15.1.3, and 15.1.4, respectively, is not affected by the changes for Cycle 11 in Section 1.0. Therefore, the relative PCS cooldown rate and severity of each of the above events remains unchanged from previous event dispositions beginning with Cycle a<19>.

For this category of events, the Increase in Steam Flow event (15.1.3) remains bounding of events 15.1.1, 15.1.2 and 15.1.4. The MDNBR for Event 15.1.3 will be reanalyzed for the Cycle 11 changes given in Section 1.0.

15.1.1 Decrease in Feedwater Temperature 15.1.1.1 Event Description A decrease in feedwater temperature event may result from the loss of one of several of the feedwater heaters. This loss may be due to the loss of extraction steam flow from the turbine generator or due to an accidental opening of a feedwater heater bypass line.

The event results in a decrease of the secondary side enthalpy leading to an increase in the primary-to-secondary side heat transfer rate. The steam generator outlet temperature on the primary side decreases causing the core inlet temperature to also decrease. In the presence of a negative moderator coefficient, reduced core inlet temperature results in an increase in the core power and a decrease in thermal margin.

15.1.1.2 Event Disposition and Justification As noted in Section 15.1, this event is bounded by the Increase in Steam Flow event

{Event 15.1.3).

15.1.2 Increase in Feedwater Flow 15.1.2.1 Event Description EMF-92-178 Page 55 The ln<?rease in Feedwater Flow event is initiated by a failure in the feedwater system.

The failure may be a result of: (1) a complete opening of a feedwater regulating valve, (2) over-speed of the feedwater pumps with the feedwater valve in the manual position, (3) inadvertent startup of the second feedwater pump at low power, (4) startup of the auxiliary feedwater system, or (5) inadvertent opening of the feedwater control valve bypass line.

The event results in an increase in the primary-to-secondary side heat transfer rate due to increased feedwater flow. The steam generator outlet temperature on the primary side decreases causing the core inlet temperature to also decrease. In the presence of a negative moderator coefficient, a reduced core inlet temperature results in an increase in the core power and a decrease in thermal margin.

15.1.2.2 Event Disposition and Justification As noted in Section 15.1, this event is bounded by the Increase in Steam Flow event (Event 15.1.3).

15.1.3 Increase in Steam Flow 15.1.3.1 Event Description The increase in steam flow event is initiated by an increase in steam demand. The increased steam demand may be initiated by the operator or by regulating valve malfunction.

The step increase in steam flow results from a rapid opening of the turbine control valves, atmospheric dump valves or the turbine bypass valve to condenser.

The event initiator is a step increase in steam flow. The feedwater regulating valves open to increase the feedwater flow in an attempt to match the increased steam demand and maintain steam generator water level. In response to the increased steam flow, the secondary system pressure decreases, resulting in an increase in the primary-to-secondary heat transfer rate. The primary side steam generator outlet temperature decreases due to the enhanced

EMF-92-178 Page 56 heat removal. As a consequence, the primary system core average temperature decreases and the primary system fluid contracts, resulting in an outsurge of fluid from the pressurizer.

The pressurizer level and pressure decrease as fluid is expelled from the pressurizer. If the MTC is negative, the reactor core power increases as the moderator temperature decreases due to the mismatch between the power being removed by the steam generators and the power being generated in the core.

TM/LP and VHP trips are available to prevent the violation of the acceptance criteria.

Depending on the magnitude of the increase in steam demand, a reactor trip may not be activated. Instead, the reactor system will reach a new steady-state condition at a power level greater than the initial power level which is consistent with the increased heat removal rate.

The final steady-state conditions which are achieved will depend upon the magnitude of the MTC. If the MTC is positive, the reactor power would decrease as the core average coolant temperature decrease~. and this event would not produce a challenge to the acceptance criteria.

This event is a moderate frequency event (Table 15.0.1-1). The acceptance criteria for

. this event are listed in 15.0.1.1. Single failure criteria for Palisades are given in 15.0.11. For this analysis, the systems challenged in this event are redundant; no single active failure in the RPS or ESF will adversely affect the consequences of the event.

15.1.3.2 Event Disposition and Justification The parameters controlling the severity of the transient are: (1) the secondary steam flow (load), (2) the primary-to-secondary heat transfer, (3) the moderator reactivity coefficient, (4) the Doppler reactivity coefficient, (5) the reactor safety system setpoints, and (6) the scram reactivity. The reference analysisC3> evaluated the severity of the transient at full power. As shown in analyses for previous cycles, the transient initiated from hot full power bounds all other modes of operation. Because of the increase in radial peaking limits for Reload 0,

  • DNBR and peak LHR analyses are required.

15.1.3.3 Definition of Events Analyzed EMF-92-178 Page 57 This event is predominantly a depressurization event and is evaluated at full power conditions. At full power, the margin to limits is the smallest and, therefore, bounds operation at lower power levels. The end-of-cycle moderator and Doppler feedback coefficients were selected to maximize the challenge to the SAFDLs. The time in the cycle will determine the value of the MTC. If the MTC is negative, there will be a positive reactivity insertion, the magnitude of which is dependent upon the magnitude of the MTC. If the MTC is positive, then negative reactivity will be inserted as the coolant temperature decreases, causing the power to decrease with less challenge. The reactor control rod system at Palisades is disabled so that the control rods will not withdraw automatically in response to the decrease in core average temperature. Therefore, the consequences of this event are bounded at end-of-cycle conditions when the MTC is at its maximum negative value.

15.1.3.4 Analysis Results The transient response of the reactor system was calculated using the PTSPWR2(12>

computer program in Reference 3, including plots of key system variables and a sequence of events. The core thermal hydraulic boundary conditions from the PTSPWR2 calculation are used as input to the XCOBRA-lllC code(13> to predict the MDNBR. Based on the peaking factors given in Table 15.0.3-1 for Reload 0 fuel, the MDNBR for this event is 1.587 and the peak pellet LHR is 16.98 kW/ft.

15.1.3.5 Conclusion The results of the analysis demonstrate that the event acceptance criteria are met since the predicted MDNBR is greater than the safety limit. The critical heat flux correlation limit ensures that, with 95 % probability and 95 % confidence, DNB is not expected to occur; therefore, no fuel is expected to fail. The fuel centerline melt threshold of 21 kW/ft is not penetrated during this event.

15.1.4 Inadvertent Opening of a Steam Generator Relief or Safety Valve 15.1.4.1 Event Description EMF-92-178

  • Page 58 This event is initiated by an increase in steam flow caused by the inadvertent opening of a steam generator relief or safety valve. The increase in steam flow rate causes a mismatch between the heat generation rate on the primary side and the heat removal rate on the secondary side.

15.1.4.2 Event Disposition and Justification The increase in steam flow due to opening a steam generator valve is less than that considered in the Increase in Steam Flow event (Event 15.1.3), and therefore is bounded by Event 15.1.3.

15.1.5 Steam System Piping Failures Inside and Outside of Containment 15.1.5.1 Event Description The steam line break event is initiated by a double ended guillotine break of the main steam line which leads to an uncontrolled steam release from the secondary system. The increase in energy removal through the secondary system results in a severe overcooling of the primary system. In the presence of a negative MTC, this cooldown results in a large decrease in the shutdown margin and a return to power. This return to power is exacerbated because of the high power peaking factors which exist as result of the most reactive control rod being assumed stuck in a fully withdrawn position.

15.1.5.2 Event Disposition and Justification The consequences of this event are controlled by the following: (1) steam flow rate out of the ruptured steam line, (2) primary-to-secondary heat transfer, (3) the primary pump assumptions (i.e., with or without offsite power), (4) moderator reactivity coefficient, (5) Doppler reactivity coeffi~ient, (6) core power, and (7) Technical Specification shutdown margin. The consequences of a main steam line break are dependent on the competing effects of

  • shutdown reactivity as a result of a reactor trip and the positive reactivity insertion due to PCS overcooling. The system response for this event remains unchanged from Cycle 9.

In

EMF-92-178 Page 59 addition, the Cycle 11 changes do not affect the release path to the environment. The changes incorporated in Cycle 11 will not adversely impact MDNBR or peak LHR (e.g., the radial peaking at the time of MDNBR used in Reference 3 bounds that for* Cycle 11).

Therefore, the amount of fuel failure calculated in the reference analysis(3) remains applicable for Cycle 11.

The fuel failure analysis in Reference 6 is based on a steam line break inside of containment. Because of the outlet flow restrictors, the thermal-hydraulic response for a break inside containment will be identical to that for a break outside of containment. Further, the amount of fuel failure will be identical for the two break locations.

Since the changes introduced by Cycle 11 will not adversely impact the amount of fuel failure relative to the Reference 3 analysis, the bounding radiological consequence analysis given in Reference 6 remains applicable to Cycle 11.

15.2 Decrease in Heat Removal by the Secondary System EMF-92-178 Page 60 The initiating mechanisms for the loss of external load event (15.2.1 ), turbine trip event (15.2.2), loss of condenser vacuum event (15.2.3), closure of the main steam isolation valves (15.2.4) and the heatup phase of the feedwater system pipe break event (15.2.8) are not affected by any of the Cycle 11 changes. Therefore, the relative severity of these events as established in previous dispositions beginning with ~ycle a(19) remains valid. The loss of load event, 15.2.1, as biased in previous analyses(3.4) was found to be bounding of Events 15.2.2, 15.2,3, 15.2.4 and the heatup period of Event 15.2.8.

15.2.1 Loss of External Load 15.2.1.1 Event Description A Loss of External Load event is initiated by either a loss of external electrical load or a turbine trip. Upon either of these two conditions, the turbine stop valve is assumed to rapidly close (0.1 second). The plant response to this event is negligibly affected by assuming a faster valve closure time. Normally *a reactor trip would occur on a turbine trip, however, to calculate a conservative system response, the reactor trip on turbine trip is disabled. The steam dump system (atmospheric dump valves - ADVs) is assumed to be unavailable. These assumptions allow the Loss of External Load event to bound the consequences of Event 15.2.2 (Turbine Trip - steam dump system unavailable) and Event 15.2.4 (Closure of both MSIVs - valve closure time is comparable to the turbine stop valve).

The Loss of External Load event primarily challenges the acceptance criteria for both primary and secondary system pressurization and DNBR. The event results in an increase in the primary system temperatures due to an increase in the secondary side temperature. As the primary system temperatures increase, the coolant expands into the pressurizer causing an increase in the pressurizer pressure.

The primary system is protected against overpressurization by the pressurizer safety and relief valves. Pressure relief on the secondary side is afforded by the steam line safety/relief valves. Actuation of the primary and secondary system safety valves limits the magnitude of the primary system temperature and pressure increase.

EMF-92-178 Page 61 With a positive BOC MTC, increasing primary system temperatures result in an increase in core power. The increasing primary side temperatures and power reduces the margin to thermal limits (i.e., DNBR limits) and challenges the DNBR acceptance criteria.

15.2.1.2 Event Disposition and Justification The parameters influencing the severity of the transient include: (1) PCS high pressure trip setpoint, (2) PCS over pressure relief capacity, (3) Primary-to-secondary heat transfer, (4)

Secondary side pressure relief capability, (5) Moderator reactivity coefficients, and (6) Doppler reactivity coefficient. This event initiated from full power bounds all other operating modes.

The reference analysisC3* 17) evaluated the following two cases: maximum primary system overpressure and MDNBR. From Reference 17, the MDNBR case for this event is non-limiting relative to other AOOs. Since this is a pressurization event (increasing pressure increases DNBR) and other more limiting MDNBR events are b'eing reanalyzed for Cycle 11 (e.g., the uncontrolled rod withdrawal), a MDNBR analysis for this event will not be performed for Cycle

11. The increase in radial peaking limits for Reload 0 will not adversely impact the evaluation of the transient pressurizer response in Reference 3; thus, this subevent will not require reanalysis for Cycle 11.

15.2.2 Turbine Trip 15.2.2.1 Event Description This event is initiated by a turbine trip which results in the rapid closure of the turbine stop valves. A reactor trip would occur on a turbine trip and the steam dump system would operate to mitigate the consequences of this event. The primary system is protected against overpressurization by the pressurizer safety and relief valves. Pressure relief on the secondary side is afforded by the steam line safety/relief valves.

15.2.2.2 Event Disposition and Justification The following reactor conditions assumed for the Loss of External Load event (Event 15.2.1) are conservative relative to the Turbine Trip event: (1) a conservatively fast turbine stop valve closure time, (2) no reactor trip coincident with the turbine trip, and (3) the atmospheric

EMF-92-178 Page 62 dump valves are assumed to be unavailable. Therefore, this event is bounded by the Loss of External Load event.

15.2.3 Loss of Condenser Vacuum 15.2.3.1 Event Description This event is initiated by a reduction in the circulating water flow or an increase in the circulating water temperature which can impact the condenser back pressure. This condition can result in a turbine trip without the availability of steam bypass to the condenser. The primary system is protected against overpressurization by the pressurizer safety and relief valves. Pressure relief on the secondary side is afforded by the steam line ~afety/relief valves.

15.2.3.2 Event Disposition and Justification At rated power and power operating modes, the assumptions made for the Loss of External Load event (Event 15.2.1) are conservative relative to the Loss of Condenser Vacuum.

From operating modes other than rated power, the operator has sufficient time to control the primary and secondary system temperatures. These dispositions will not change for Cycle *11.

15.2.4 Closure of the Main Steam Isolation Valves (MSIV) (BWR) 15.2.4.1 Event Description Closure of the Main Steam Isolation Valves event is initiated by the loss of control air to the MSIV operator. The valves are swinging check valves designed to fail in the closed position. The inadvertent closure of the MSIVs is primarily a BWR event, however, the closure of these valves in a PWR can drastically reduce the steam load.

15.2.4.2 Event Disposition and Justification Closure of the MSIVs is less than 5 seconds, but comparable to the value used in Event 15.2.1 (0.1 seconds). A MSIV closure event will progress i.n a similar fashion as a Loss of External Load (Event 15.2.1 ), but at a slower rate. The consequences of Event 15.2.1 will bound those for Event 15.2.4 because of the more rapid valve closure time. This disposition will not change for Cycle 11.

15.2.5 Steam Pressure Regulator Failure EMF-92-178 Page 63 Palisades does not have steam pressure regulators. Therefore, the Steam Pressure Regulator Failure event is not considered in this analysis.

15.2.6 Loss of Nonemergency A.C. Power to the Station Auxiliaries 15.2.6.1 Event Description A Loss of Nonemergency A.C. Power to the Station Auxiliaries event may be caused by a complete loss of the offsite grid together with a turbine generator trip or by a failure in the onsite A. C. power distribution system.

The loss of A.C. power may result in the loss of power to the primary coolant pumps and condensate pumps which, in turn, results in the loss of the main feedwater pumps. The combination of the decrease in primary coolant flow rate, the cessation of main feedwater flow and trip of the turbine generator compounds the event' consequences.* The decrease of both primary coolant flow and main feedwater decreases the primary-to-secondary system heat transfer rate resulting in the heatup of the primary system coolant. The increase in primary system coolant temperature increases the overpressurization potential and increases the threat of penetrating DNB.

15.2.6.2 Event Disposition and Justification The event is most limiting when initiated from full power conditions. During this mode of operation the stored heat in the fuel rods is maximized and the margin to DNB is minimized.

This event can be separated into two distinct phases: the near-term and the long-term. The near-term phase is characterized by the loss of power resulting in the coastdown of the primary coolant pumps, the coastdown of the main feedwater pumps and the trip of the turbine generator. The coastdown of the primary coolant pumps causes an immediate reduction in thermal margin. The trip of the reactor and the subsequent insertion of control rods terminates the challenge to DNB limits.

The near-term phase of the event is similar to that of a Loss of Forced Reactor Coolant

EMF-92-178 Page 64 Flow transient (Event 15.3.1 ). The near-term consequences of this event are addressed in the analysis of Event 15.3.1.

The long-term consequences of a Loss of A.C. Power event are determined by the heat removal capacity of the auxiliary feedwater system. The long-term portion is similar to the Loss of Normal Feedwater Flow transient (Event 15.2.7). The long-term effects are, therefore, addressed by the disposition of the Loss of Normal Feedwater Flow event. The changes for Cycle 11 will not alter this disposition.

15.2. 7 Loss of Normal Feedwater Flow 15.2.7.1 Event Description A Loss of Normal Feedwater Flow transient is initiated by the trip of the main feedwater pumps or a malfunction in the feedwater control valves. The loss of main feedwater flow decreases the amount of subcooling in the secondary-side d.owncomer which diminishes the primary-to-secondary system heat transfer and leads to an increase in the primary system coolant temperature. As the primary system temperatures increase, the coolant expands into the pressurizer which increases the pressure by compressing the steam volume.

. i.-

The opening of the secondary-side safety valves controls the heatup of the primary-side. The long-term cooling of the primary system is governed by the heat removal capacity of the auxiliary feedwater flow. The auxiliary feedwater pumps are automatically started upon a steam generator low liquid level signal.

15.2.7.2 Event Disposition and Justification A Loss of Normal Feedwater Flow event is only credible for rated power and power operating conditions. The worst consequences occur when the feedwater is lost during rated power operation since more stored heat is contained in the fuel than in other modes of operation.

For the initial PCS heatup phase of the transient, both the DNB and the primary system

EMF-92-178 Page 65 overpressurization acceptance criteria are challenged. The DNB challenge is maximized when it is assumed that*offsite power is lost causing the primary coolant pumps to coastdown.

After the reactor trip system is activated, the core power is drastically reduced alleviating the challenge to DNB. The loss of forced reactor coolant flow event (Event 15.3.1) bounds the short term DNB consequences of a loss of normal feedwater transient.

For the longer term phase of the transient, the slow PCS heatup threatens both the overpressurization of the primary system by filling the pressurizer with liquid, and the dryout of the steam generators. The limiting cases in the reference analysis assumed an auxiliary feedwater flow rate of 300 gpm distributed to both steam generators.

The parameters influencing the severity of the long term phase of the transient include:

(1) decay heat generation, (2) secondary safety/relief valve settings, (3) primary coolant pump

Nominal PCS and secondary conditions, (2) Minimum steam generator inventory, and (3)

Maximized PCS pressure. The reference analysis utilized a power decay curve incorporating the power response to scram and the long-term effects of decay which bounds the nominal kinetics parameters for Cycle 11. The increase radial peaking limits for Reload 0 will not adversely impact this event. Thus, the reference analysis remains bounding.

15.2.8 Feedwater System Pipe Breaks Inside and Outside Containment 15.2.8.1 Event Description A Feedwater System Pipe Break event occurs when a main feedwater system pipe is ruptured. The ruptured pipe will cause a blowdown of the affected steam generator if the break occurs upstream of the feedline check valve. If the rupture occurs downstream of the check valve, the event would behave much like the Loss of Normal Feedwater Flow transient.

Since the auxiliary feedwater flow is injected into the steam generators via a separate piping

  • the pipe rupture..

EMF-92-178 Page 66 The event results in both a primary system cooldown and a heatup. Initially, the event results in a cooldown of the primary-side coolant due to the energy removal during the blowdown stage of the event. The eventual depletion of secondary-side inventory and lack of main feedwater will cause the primary system to heatup much like a Loss of Normal Feedwater Flow event.

15.2.8.2 Event Disposition and Justification

  • During power operation, the cooldown consequences of this event are bpunded by the main steam line break event (15.1.5) and the heatup consequences are bounded by the Loss of Load Event (15.2.1 ). The long-term cooling requirements are addressed in the Loss of Normal Feedwater event (15.2.7). Feedline pipe breaks from non-power operating modes, are bounded by the main steam line break. The system configuration and operational conditions for Cycle 11 remain unchanged from previous cycles, thus this event is bounded by Events 15.1.5, 15.2.1 and 15.2.7.
  • ,'}-

15.3 Decrease in Reactor Coolant System Flow 15.3.1 Loss of Forced Reactor Coolant Flow 15.3.1.1 Event Description EMF-92-178 Page 67 This event is characterized by a total loss of forced reactor coolant flow which is caused by the simultaneous loss of electric power to all of the reactor primary coolant pumps.

Following the loss of electrical power, the primary coolant pumps begin to coast down.

If the reactor is at power when the event occurs, the loss of forced coolant flow causes the primary coolant temperatures to rise rapidly. This results in a rapid reduction in DNB margin, and could result in DNB if the reactor is not tripped promptly. Also, as the primary coolant temperatures rise the primary coolant expands, which causes an insurge into the pressurizer, a compression of the pressurizer steam space and a rapid increase in primary coolant system pressure. The primary system overpressurization will be mitigated by the action of the primary system safety valves and the reduction in core power following reactor trip. Reactor trip signals are provided from low primary coolant system flow.

The MDNBR is controlled by the interaction of the primary coolant flow decay and the core power decrease following reactor trip. The power to flow ratio initially increases, peaks, and then declines as the challenge to the SAFDLs is mitigated by the decline in core power due to the reactor trip. If a reactor trip can be obtained promptly, the power to flow ratio will first peak and then decrease during the transient such that the SAFDLs will be no longer challenged.

The pump coastdown characteristics and the timing of the reactor trip, trip delays and scram rod insertion characteristics are key parameters. Natural circulation flow is developed in the primary system and the steam generators are available to remove the decay power.

Therefore, long-term cooling of the core can be achieved.

The primary concern with this event is the challenge to the SAFDLs. The event is analyzed to verify that the reactor protection system can respond fast enough to prevent

penetration of the DNBR SAFDL.

EMF-92-178 Page 68 This event is classified as a moderate frequency event (Table 15.0.1-1).

The acceptance criteria are as described in 15.0.1.1. For this analysis, the systems challenged in this event are redundant; no single active failure in the RPS or ESF will adversely affect the consequences of the event. Long term recovery is provided by the auxiliary feedwater system, as demonstrated in the analysis of Event 15.2.7 in Reference 17.

15.3.1.2 Event Disposition The most limiting loss of flow transient is initiated from rated power. The transient is initiated by tripping all four primary coolant pumps. As the pumps coast down, the core flow is reduced, causing a reactor scram on low flow.

As the flow coasts down, primary temperatures increase. This increase in temperature causes a subsequent power rise due. to moderator reactivity feedback. The primary ch~llenge to DNB, as well as overpressurization, is from the decreasing flow rate, increasing coolant temperatures and ascending reactor power. Because of the increased radial peaking limits for Reload 0, DNBR and peak LHR analyses are required. The overpressurization is mitigated by the primary system safety valves and reduced power after scram.

15.3.1.3 Definition of Events Analyzed The event is initiated by simultaneously tripping of all of the primary coolant pumps.

The pump coastdown is governed by a conservative estimate of the pump flywheel inertia, the homologous pump curves and the loop hydraulics. Reactor trip is delayed until the low primary coolant system loop flow signal is obtained. This trip setpoint is conservatively reduced to account for uncertainties in flow measurement.

This event is analyzed from full power initial conditions. The core thermal margins are minimized at full power conditions resulting in this being the bounding mode of operation for

  • this event. One case is analyzed for this event to assess the challenge to the DNB SAFDL.

The event analysis is biased to minimize DNBR. The steam line bypass and the atmospheric

EMF-92-178 Page 69 dump valves are both assumed not to operate, which again most challenges the DNB SAFDL.

15.3.1.4 Analysis Results The transient response of the reactor system was calculated using the PTSPWR2 computer program in Reference 3, including plots of key system variables and a sequence of events. The core thermal hydraulic boundary conditions from the PTSPWR2 calculation are used as input to the XCOBRA-lllC code to predict the MDNBR for the event. Based on the peaking factors given in Table 15.0.3-1 for Reload 0 fuel, the MDNBR for this event is 1.178 and the peak pellet LHR is 15.58 kW/ft.

15.3.1.5 Conclusion The 95/95 DNB correlation safety limit is not penetrated by this event. Maximum peak pellet LHR for this event is below the incipient fuel centerline melt criterion of 21 kW/ft. Thus, all applicable acceptance criteria are met.

15.3.2 Flow Controller Malfunction There are no flow controllers on the PCS at Palisades. Therefore, this event is not credible.

15.3.3 Reactor Coolant Pump Rotor Seizure 15.3.3.1 Event Description The locked rotor eveqt is caused by an instantaneous seizure of a primary coolant pump rotor. Flow through the affected loop is rapidly reduced, causing a reactor trip due to a low primary loop flow signal. Following the reactor trip, the heat stored in the fuel rods continues to be transferred to the primary coolant. Because of the reduced core flow, the coolant temperatures will begin to rise, causing expansion of the primary coolant and consequent pressurizer insurge flow and PCS pressurization. As the pressure increases, pressurizer sprays and safety valves would act to mitigate the pressure transient.

The rapid reduction in core flow and the increase in coolant temperature may seriously

.... ~;

EMF-92-178

  • Page 70 challenge or penetrate the DNBR SAFDL. The event is thus evaluated to assess the DNBR challenge. The fuel centerline melt SAFDL is not seriously challenged by the small power increase typical of this event. PCS pressurization criteria have not been approached in SPC analyses of this event; no case addressing pressurization is therefore performed.

The event as simulated is structured to provide a bounding determination of MDNBR for both the locked rotor and broken shaft (15.3.4) events.

The reactor pump rotor seizure is an infrequent event (Table 15.0.1-1 ). The acceptance criteria for this event are presented in Section 15.0.1.1.

For this analysis, the systems challenged in this event are redundant; no single active failure in the RPS or ESF will adversely affect the consequences of the event. The auxiliary feedwater pumps will provide cooling capability after scram, as demonstrated in Section 15.2.7 of Reference 17.

15.3.3.2 Event Disposition The controlling parameters for the pump seizure event are identical to those for the loss of flow event. Therefore, the same arguments will hold for this event as noted in Section 15.3.1.2, requiring a DNBR analysis for Reload 0.

15.3.3.3 Definition of Events Analyzed One case is analyzed for this event to maximize the challenge to the DNB limit. The bounding operating mode for this event is full power initial conditions.

15.3.3.4 Analysis Results The transient response of the reactor system was calculated using the PTSPWR2 computer program in Reference 3, including plots of key system variables and a sequence of events. The core thermal hydraulic boundary conditions from the PTSPWR2 calculation are used as input to the XCOBRA-lllC code to predict the MDNBR for the event. The MDNBR for this event is 1.139 and the peak pellet LHR is 15.98 kW/ft. Based on a MDNBR of 1.139, this infrequent event results in about 0.1 % fuel failure due to penetrating DNBR limits. The

EMF-92-178 Page 71 radiological consequences of this amount of fuel failure are a very small fraction of the 1 O CFR 100 limits.

15.3.3.5 Conclusion The radiological consequences due to penetration of DNB for this event are a very small fraction of the 1 O CFR 100 limits. No additional radiological consequences occur from fuel centerline melt since peak LHR is less than 21 kW/ft. Thus, the event acceptance criteria are met.

15.3.4 Reactor Coolant Pump Shaft Break 15.3.4.1 Event Description This event is initiated by a failure of a PCS pump shaft resulting in a free-wheeling impeller. The impact of a coolant pump shaft break is a loss of pumping power from the affected pump and a reduction in the PCS flow rate. The flow reduction due to the seizure of a pump rotor is more severe than that for a shaft break; however, the potential for flow reversal is greater for the shaft break event. The event is terminated by the low reactor coolant flow trip.

15.3.4.2 Event Disposition The event is most limiting at rated power conditions because of a minimum margin to DNBR limits. The initial flow reduction for this event is bounded by that for the Reactor Coolant Pump Rotor Seizure event (Event 15.3.3). The potential for greater reverse flow due to a shaft break is accounted for in the seized rotor analysis by decreasing the rotor inertia to zero at the time of predicted reversed flow. The severity of the pump shaft break event is bounded by Event 15.3.3. Since the Cycle 11 changes summarized in Section 1.0 will not adversely impact the relative PCS flow reduction for the loss of flow Events (15.3), this event is bounded by Event 15.3.3 as in previous dispositions.

15.4 Reactivity and Power Distribution Anomalies EMF-92-178 Page 72 15.4.1 Uncontrolled Control Rod Assembly Withdrawal from a Subcritical or Low Power Startup Condition 15.4.1.1 Event Description This event is initiated by the uncontrolled withdrawal of a control rod bank, which results in the insertion of positive reactivity and consequently a power excursion. It could be caused by a malfunction in the reactor control or rod control systems. The consequences of a single bank withdrawal from reactor critical, hot standby and hot shutdown (subcritical) operating conditions are considered in this event category; the consequences at power operating conditions are considered in Event 15.4.2.

The control rods are wired together into preselected bank configurations. These circuits prevent the control rods from being withdrawn in other than their respective banks.

Power is supplied to the banks in such a way that no more than two banks can be withdrawn at the same time and in their proper withdrawal sequence.

The reactivity insertion rate is rapid enough that very high neutron powers are calculated, but Qf short enough duration that excessive energy deposition does not occur.

Rod surface heat flux lags the neutron power but still approaches a significant fraction of full power. Because the event is very rapid, primary coolant temperature lags behind power. The reactivity insertion rate is initially countered by the fuel temperature reactivity (Doppler) coefficient followed by trip and rod insertion.

The power transient (as well as the control rod withdrawal) is eventually terminated by the following plant protection:

(1)

(2)

Non-safety grade high rate-of-change of power trip,.0001 % to 15 % power (no credit taken)

VHP trip (3)

TM/LP trip

EMF-92-178.

Page 73 (4)

High pressurizer pressure trip (5)

High rate-of-change of power alarms, which initiate Rod Withdrawal Prohibit Action (no credit taken).

(6)

The reactor is tripped (circuit breakers 42-01 and 42-02 open) and the plant is in hot shutdown or below when a pump out of service for more than 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> (Reference 7).

Further protection is provided by the Doppler reactivity feedback in the fuel and by available DNBR margin between the initial operating condition and the DNB thermal limit.

15.4.1.2 Event Disposition and Justification Based on the Reference 3 analysis, this event is non-limiting relative to other AOO events that are being reanalyzed for Cycle 11. Chan~es introduced in Cycle 11 will not alter

  • this conclusion. Thus, this event will not be reanalyzed for Cycle 11.

15.4.2 Uncontrolled Control Rod Bank Withdrawal at Power 15.4.2.1 Event Description As with Event 15.4.1, this event is initiated by an uncontrolled withdrawal of a control rod bank. This withdrawal adds positive reactivity to the core which leads to potential power and temperature excursions.

Event 15.4.2 considers the consequences of control bank withdrawals at rated and operating _initial power levels.

The reactor protection trip system is designed and set to preclude penetration of the SAFDLs. Because of the design of this analysis, the TM/LP and VHP trips are principally challenged.

The TM/LP trip function is designed and set to protect against DNB. Principal DNB parameters such as power (the highest auctioned value of either calorimetric or neutronic

  • power), core inlet temperature and core power distribution are measured. The function decreases margin to trip setpoint when process variables indicate a decrease in operating

EMF-92-178 Page 74 margin. This function is based on the core protection boundaries. Operation within these boundaries assures protection of the SAFDLs.

A broad range of reactivity insertion rates and initial operating conditions are possible.

The range of reactivity insertion is from very slow, as would be associated with a gradual boron dilution, and bounded on the fast end of the range by a bank withdrawal.

The objective of the analysis is to demonstrate the adequacy of the trip setpoints to assure meeting the acceptance criteria. To assure this objective, the analysis considers a spectrum of reactivity insertion rates and initial power levels. Since neutronic feedback as a function of cycle exposure and design also influences the results, these effects are also included in the analysis.

This event is classified as a moderate frequency event (Table 15.0.1-1 ).

The acceptance criteria are as described in 15.0.1.1. The single failure criteria are given in 15.0.11.

The safety systems challenged in this event are redundant and no single active failure will adversely affect the consequences of the -event.

15.4.2.2 Event Disposition and Justification The reference analysis(3,s) evaluated the severity of the transient over a range of values for the reactivity insertion rate, moderator and Doppler reactivity coefficients and initial power.

The increase in radial peaking limits will require DNBR and peak LHR analyses for Reload 0.

15.4.2.3 Definition of Events Analyzed The References 3 and 8 evaluated the consequences of this event for an uncontrolled control rod bank withdrawal. A spectrum of reactivity insertion rates were evaluated in order to bound events ranging from a slow dilution of the primary system boron concentration to the fastest allowed control bank withdrawals. Specifically, the analysis encompasses reactivity insertion rates from 1. x 1 o-6 to 5. x 1 o*5 !J.. p/sec. For Cycle 11, the MDNBR will be reevaluated for the case with the lowest MDNBR from the previous analyses(3,s).

15.4.2.4 Analysis Results EMF-92-178 Page 75 The transient.response of the reactor system was calculated using the PTSPWR2 computer program in Reference 8, including plots of key system variables and a sequence of events. The core thermal hydraulic boundary conditions from the PTSPWR2 calculation are used as input to the XCOBRA-lllC code to predict the MDNBR for the event. Based on the peaking factors given in Table 15.0.3-1 for Reload 0 fuel, the MDNBR for this event is 1.443 and the peak pellet LHR is 17.12 kW/ft.

15.4.2.5 Conclusion Reactivity insertion transient calculations demonstrate that the DNB correlation limit will not be penetrated during any credible reactivity insertion transient at full power. The maximum peak pellet linear heat generation rate for this event is less than the fuel centerline melt criterion of 21 kw/ft. Applicable acceptance criteria are therefore met and the adequate functioning of the TM/LP trip is demonstrated.

15.4.3 Control Rod Misoperation The control rod misoperation events encompass transient and steady state configurations resulting from different event initiators. The specific events analyzed under this event category are:

15.4.3.1 Dropped control rod or bank Statically misaligned control rod or bank Single control rod withdrawal Core Barrel Failure Event Description Dropped Control Rod or Bank The dropped rod and dropped bank events are initiated by a de-energized control rod drive mechanism or by a malfunction associated with a control rod bank. The dropped rod events are classified as Moderate Frequency events. Acceptance criteria are given in 15.0.1.1.

EMF-92-178 Page 76 In the dropped rod or dropped bank events, the reactor power initially drops in response to the insertion of negative reactivity. This results in reductio!1 of the moderator temperature due to a mismatch between core power being generated and secondary system load demand. The core power redistributes due to the local power effect of the dropped rod or bank. The reactor power will return to the initial level due to the combined effects of a negative MTC and reduced moderator temperature. The moderator temperature will not decrease below the temperature necessary to return the core to initial power. The rod and bank ~rop events challenge the DNBR SAFDL because of the increased radial peaking and the potential return to initial power. Depending on the worth of the dropped rod or bank, the reactor will trip on a VHP or a TM/LP trip.

Statically Misaligned Control Rod or Bank The static misalignment events occur when a malfunction of the Control Rod Drive mechanism causes a control rod to be out df alignment with its bank. Misalignment occurs when the rod is either higher or lower than any of the other control rods in the same bank or when a bank(s) is out of alignment with the Power Dependent Insertion Limit (PDIL). During this event, the reactor is at steady-state rated full power (Mode 1) or part-power (Mode 2) :.

conditions with enhanced power peaking. This event is classified as a Moderate Frequency occurrence. Acceptance criteria are given in 15.0.1.1.

In the static rod misalignment event, a control bank is inserted but one of the rods remains in a withdrawn state. This results in a local increase of the radial power peaking factor and a corresponding reduction in the DNB margin. The most severe misalignment occurs at full power operation, with one bank inserted beyond its control rod insertion limit and one of the bank control rods fully withdrawn. The radial power redistribution consequences of a reverse misalignment, i.e., one rod is inserted while the bank remains withdrawn, are essentially the same as the dropped rod event. The bank misalignment event occurs when one bank is inserted or withdrawn beyond the PDIL. The situation of concern is the power interval between 35 % to 65 % where control rod banks 3 and 4 are used.

Single Control Rod Withdrawal EMF-92-178 Page n The rod withdrawal event is initiated by an electrical or mechanical failure in the Rod Control System that causes the inadvertent withdrawal of a single control rod. A rod is withdrawn from the reactor core causing an insertion of positive reactivity which results in a power excursion transient. The movement of a single rod out of sequence from the rest of the bank results in a local increase in the radial power peaking factor. The combination of these two factors results in a challenge to DNB margin. The system response is essentially the same as that occurring in the Uncontrolled Bank Withdrawal event at power (15.4.2).

Core Barrel Failure This event is initiated by the circumferential rupture of the core support barrel. The core stop supports serve to support the barrel and the reactor core by transmitting all loads

. directly to the vessel.

The clearance between the core barrel and the supports is approximately one-half inch at operating temperatures. The worst possib.le axial location of the barrel rupture is at the mid plane of the vessel nozzle penetrations. This forms a direct flow path between the inlet and exit nozzles in parallel with the path that goes through the core.

The core sustains a small reactivity transient induced by the motion of the core relative to the inserted rod bank(s).

Reactor protection for the Core Barrel Failure event during hot shutdown, refueling shutdown, cold shutdown, and refueling operating conditions is provided by Technical Specification Shutdown Margin requirements.

For the reactor critical and hot standby operating conditions, reactor protection is provided by the VHP trip and a non-safety grade high rate-of-change of power trip. For the rated power and power operating conditions, reactor protection is afforded for the VHP and TM/LP trips.

The probability of a circumferential rupture of the core support barrel has the same low probability of occurrence as a major rupture of the primary system piping. Therefore, this

  • event is classified as a Limiting Fault event.

15.4.3.2 Event Disposition and Justification Dropped Control Rod/Bank EMF-92-178 Page 78 Because of the increased radial peaking factor, the dropped control rod/bank events will require DNBR and peak LHR analyses for Reload 0. Limiting conditions will be used to bound both rod and low worth bank drop events (i.e., bank drop events that do not initiate a reactor scram). For larger worth banks (i.e., bank drop events that initiate a scram), the Reference 3 PTSPWR2 transient analysis remains bounding for Cycle 11 since a conservative bank worth was used. Bounding radial peaking augmentation factors for Cycle 11 will be used for both the dropped rod and dropped bank analyses.

Dropped Part-Length Control Rod A dropped part-length control rod will not be as severe as a dropped full-length control rod and is, therefore, bounded.

Malpositioning of the Part-Length Control Rod Group Use of part-length control rods is not allowed during power operation. The part-length control rods are maintained in a fully withdrawn state; therefore, this event is not credible.

Statically Misaligned Control Rod/Bank Because of a smaller radial peaking augmentation factor, a statically misaligned control rod or bank will not be as severe as a dropped full-length control rod and is, therefore, bounded.

Single Control Rod Withdrawal The withdrawal of a single control rod results in a reactivity insertion and a localized increase in radial peaking. The degradation of core conditions characteristic of a reactivity insertion transient, combined with an increase in local peaking, poses a challenge to DNBR limits. The disposition of this event is controlled by the same parameters as Event 15.4.2.

DNBR and peak LHR analyses will be performed using the core thermal hydraulic conditions from Event 15.4.2 and an appropriate radial peaking augmentation factor for Cycle 11.

EMF-92-178

  • Page 79 The consequences of a single rod withdrawal from Modes 3, 4, and 5 are either bounded or the event does not challenge the acceptance criteria. Mode 3 operation (Reactor Critical) is defined as having a power greater than 104 % and Tave greater than 525°F. Since the peak power obtained during a low power reactivity insertion increases with increasing insertion rate, the.results for a single rod withdrawal are bounded by the results for a bank withdrawal (Event 15.4.1 where the insertion rate is much larger). Mode 4 operation (Hot Standby) applies when the power is between 104 % and 2 % and any of the control rods are
  • withdrawn. The peak heat flux following a rod withdrawal decreases with increasing initial power level. Since Mode 3 includes 104 % power, Mode 4 is bounded by the results of Mode
3. Finally, Mode 5 operation (Hot Shutdown) applies when the power is less than 104 % and Tave is greater than 525°F. The most reactive rod worth is* less than the required shutdown margin; therefore, the reactor could not become critical by the withdrawal of any single rod.

Core Barrel Failure A core barrel failure is initiated by a circumferential rupture of the core barrel support.

During this event, the core experiences a small reactivity insertion due to motion of the core relative to the control rods. The event is established to be incredible during hot shutdown, refueling shutdc:>wn, cold $hutdown and refueling operation due to the Technical Specification shutdown margin requirements. The event initiated from rated power bounds the power operating, reactor critical and hot standby operating modes.

The core barrel failure event is bounded by the consequences of the control rod ejection event (15.4.8). Both of these events are classified as Limiting Faults. Specifically, the reactivity insertion rate and radial power redistribution for the control rod ejection are worse than what occurs during a core barrel failure.

15.4.3.3 Definition of Events Analyzed.

Acceptable outcomes for these control rod misoperation events rely only on the RPS

  • or on the Technical Specifications limiting conditions of operation. The elements of the RPS challenged are redundant and have been designed to provide their function in the event of a

EMF-92-178 Page 80 single failure in the RPS. Single failures in the RPS or Engineered Safety Features thus do not affect event results. Single failure criteria for the Palisades plant are given in 15.0.11 Dropped Control Rod or Bank The rod/bank drop events challenge the acceptance criteria only in Mode 1 (Chapter 15.0.2) operation. This event is analyzed at the rated power condition with conservative*

allowances applied in a direction to minimize DNBR.

Single Control Rod Withdrawal The single rod withdrawal events challenge the acceptance criteria in operating Modes 1 through 5. The single rod withdrawal event is analyzed at conditions that exist at the time of MDNBR as calculated by PTSPWR2 during the most limiting uncontrolled rod withdrawal event. The most limiting single rod withdrawal occurs during Mode 1 conditions.

15.4.3.4 Analysis Results The events considered have in common the radial redistribution of power in the core, and can result in radial peaking factors in excess of Technical Specification limits:.. The analyses are performed by coupling a conservative power peak to transient response and DNB calculations.

The power peak associated. with each event is characterized through an augmentation factor which relates the maximum power peak to the steady-state power peak.

The steady-state power distributions and augmentation factors are calculated with the XTGPWR(16) reactor simulator.

Table 15.4.3-1 summarizes the results of the analysis of the control rod misoperation events.

Dropped Control Rod or Bank The analysis of rod drop events is performed using XTGPWR and XCOBRA-lllC. The XTGPWR code is used to calculate neutronic parameters such as rod worth and power peaking augmentation factors. A power peaking augmentation factor is included in the

EMF-92-178

  • Page 81 XCOBRA-lllC MDNBR calculation to account for radial power redistribution effects typical of the event. Simulation of the system transient for rod drops is not performed. Because the secondary system load demand remains constant through the event, the moderator will continue to cool down until moderator feedback is sufficient to restore the initial power level.

At that point, the moderator temperature stabilizes because no mismatch between core power production and secondary system load demand exists. The transient thus results in a new steady state condition characterized by a power level equal to the initial po~er, a reduced primary system pressure and a reduced core coolant temperature.

The DNBR is conservatively evaluated with an XCOBRA-lllC calculation using the initial condition power, coolant temperature and flow at a reduced pressure. The redistribution of the radial peaking factor is incorporated as noted above. A conservative radial peaking augmentation factor of 1.15 was applied for this event. The MON BR for this event is 1.186 and the peak LHR is 18.44 kW/ft for Reload 0.

The dropped bank event is distinguished from the dropped rod event by the greater magnitude of augmentation factors. PTSPWR2 and XCOBRA-lllC were used to assess the transient response and MDNBR for a dropped control bank. The PTSPWR2 performed in Reference 3 remains applicable to Cycle 11 since a bounding control bank worth was used.

A radial peaking augmentation factor of 1.30 was conservatively used for Cycle 11. The MDNBR for this event is 1.428 and the peak LHR is 18.44 kW/ft for Reload 0.

Single Control Rod Withdrawal In the analysis of the single rod withdrawal event, the core boundary conditions of average heat flux, temperature, pressure and flow are selected to conservatively bound the

. consequences of this event at rated power. The bank withdrawal analysis (15.4.2) considers reactivity insertion rates down to 1 x 1 o-6 Ii p/sec which is representative of a single rod. The boundary conditions used in the calculation of MDNBR are obtained from the limiting transient response from Reference 8 (Event 15.4.2) initiated from 91.5 % of rated power.

Those conservatively biased core bound.ary conditions are then combined in an XCOBRA-lllC calculation with a radial augmentation peaking factor calculated to bo.und the possible single

  • EMF-92-178 Page 82 rod withdrawal radial power redistribution. A radial peaking augmentation factor of 1.08 was used. The MDNBR is 1.192 and the peak LHR is 18.49 kW/ft for Reload 0.

15.4.3.5 Conclusion For the control rod/bank drop, the 95/95 DNB correlation safety limit is not penetrated by this event. Maximum peak pellet LHR for this event is below the incipient fuel centerline melt criterion of 21 kW/ft. Thus, all applicable acceptance criteria are met for these moderate frequency events.

For the single control rod withdrawal, the MDNBR for this event is greater than the 95/95 DNBR limit for the ANFP correlation. The peak LHR is less than the 21 kW/ft limit for centerline melt. Thus, all applicable acceptance criteria are met for this infrequent event.

TABLE 15.4.3-1 Event (Power)

Dropped Control Rod (100 %)

Dropped Control Bank (100

%)

Statically Misaligned Control Rod (100 %)

Statically Misaligned Bank (50

%)

Statically Misaligned Bank (65

%)

Rod Withdrawal (91.5 %)

Roo Withdrawal (50 %)

Rod Withdrawal (1 o-4 %)

Rod Withdrawal (104 %)

Rod Withdrawal (:!: 104 %)

Core Barrel Failure (100 %)

EMF-92-178 Page 83

SUMMARY

OF MDNBR AND PEAK LHR FOR CONTROL ROD MISOPERATION EVENTS Maximum Mode(a)

MDNBR LHR (kW[ft}

1 1.186 18.44 1

1.428 18.44 1

Bounded (Drop-ped Control Rod-100 %)

2 Bounded (Drop-ped Control Rod-100 %)

2 Bounded (Drop-ped Control Rod-100 %)

1 1.192 18.49 2

Bounded (Single Rod Withdrawal-Mode 1) 3 Bounded (15.4.1) 4 Bounded (15.4.1) 5 Subcritical 1

Bounded (15.4.8)

a.

These operating modes are defined in Section 15.0.2.

15.4.4 Startup of an Inactive Loop 15.4.4.1 Event Description EMF-92-178 Page 84 This event is initiated by the startup of an inactive primary coolant pump. The startup of an inactive pump can lead to an introduction of colder primary coolant into the reactor core.

The lower coolant temperature, together with a negative MTC, can cause an increase in core power and a degradation of DNB margin. Sufficient protection is available to reduce the consequences of this event.

15.4.4.2 Event Disposition and Justification Continuous power operation with less than four primary coolant pumps is not allowed :

by the Technical Specifications. Additionally, startup with less than four primary coolant pumps above hot shutdown is not allowed. Thus, this event is most limiting for an initial condition of three operating primary coolant pumps with the corresponding reduced power level and VHP trip setpoint.

For operation with one inoperative pump, the low flow trip setpoint and the VHP trip setpoint are changed to the allowable values for the selected pump condition. Under this arrangement, the VHP trip will terminate any transient resulting from the activation of an idle pump before any significant decrease in thermal margin. Although a slight temperature drop due to the startup of the inactive pump is experienced, the effect on system pressure and hot channel MDNBR is covered by the large power margin to full power conditions. Therefore, the consequences of this event are bounded by the nominal full power MDNBR with four primary coolant pump flow.

15.4.5 Flow Controller Malfunction There are no flow controllers on the PCS at Palisades. Therefore, this event is not credible.

EMF-92-178 Page 85 15.4.6 CVCS Malfunction that Results in a Decrease in the Boron Concentration in the Reactor Coolant 15.4.6.1 Event Description A boron dilution event can occur when primary grade water is added to the primary coolant system via the Chemical Volume and Control System (CVCS) or the accidental transfer of the contents of the iodine removal system during cold shutdown or refueling shutdown conditions.

The dilution of primary system boron adds positive reactivity to the core. This event can lead to an erosion of shutdown margin for subcritical initial conditions, or a slow power excursion for at-power conditions. Following operator detection of the boron dilution, operator action must be taken to terminate the dilution and to restore the required shutdown margin.

A minimum of 15 minutes (Modes 1 to 5) or 30 minutes (Mode 6) for the operator to both identify and terminate the boron dilution is allowed. Analysis of the boron dilution must demonstrate that the Technical Specification required shutdown margin is sufficient to allow at least 15 or 30 minutes before the reactor becomes critical.

In the event of a boron dilution during cold shutdown, hot shutdown or hot standby, the following indications and alarm functions are available to alert the operator:

(1)

Volume control tank level indication and high/low alarms; (2)

Letdown diverter valve position indication; (3)

Charging flow indication; and (4)

Wide range logarithmic nuclear instrumentation.

A boron dilution at rated or power operating conditions behaves in a manner similar to a slow uncontrolled rod withdrawal transient (Event 15.4.2).

15.4.6.2 Event Disposition and Justification The parameters affecting the boron dilution time-to-criticality include: (1) the mass of PCS coolant, (2) the PCS charging flow rate, (3) the PCS charging boron concentration, (4) the PCS boron concentration at event initiation versus operating mode, and (5) the PCS critical

EMF-92-178 Page 86 boron concentration versus operating mode. The changes introduced in Cycle 11 do not impact (1 ), (2) or (3). The Cycle 11 critical and shutdown boron concentrations are bounded

-for all scenarios except for dilutions during refueling and hot standby.

For these two scenarios, the Cycle 11 boron concentrations were slightly more limiting than those for the Reference 3 analysis. For a dilution during refueling, a conservative PCS volume was used in the Reference 3 analysis that more than compensates for the slightly worse refueling boron concentrations. For hot standby, the reactivity insertion rate from the diluted charging flow for Cycle 11 was calculated to be 6.5 x 1 o-6 Jl p/sec which is bounded by that assumed for the uncontrolled rod withdrawal analyses (Event 15.4.1 ). Thus, the Reference 3 analysis remains bounding and this event will not be reanalyzed for Cycle 11. _

15.4.7 Inadvertent Loading and Operation of a Fuel Assembly in an Improper Position 15.4.7.1 Event Description An inadvertent loading of a fuel assembly in an improper position can result in an alteration of the power distribution in the core which can adversely affect thermal margin.

15.4.7.2 Event Disposition and Justification The event is precluded due to the administrative controls and procedures, including startup testing, that ensure a properly loaded core. The Cycle 11 _changes will not alter this disposition.

15.4.8 Spectrum of Control Rod Ejection Accidents 15.4.8.1 Event Description This event is initiated by a failure in the control rod drive mechanism (CROM) pressure housing causing a rapid ejection of the affected control rod. The ejection of the control rod inserts positive reactivity causing an increase in core power. The resultant core thermal power excursion is limited primarily by the Doppler reactivity effect of the increased fuel temperatures and is terminated by reactor trip of all remaining control rods, activated by neutron flux signals.

Because of the increase in core power this event challenges deposited enthalpy, radiological consequences_ and pressurization acceptance criteria.

15.4.8.2 Event Disposition and Justification EMF-92-178 Page 87 This event is primarily controlled by the worth of the ejected rod and the corresponding reactivity insertion rate.. Other important parameters include: (1) Doppler reactivity coefficient, (2) radial peaking augmentation factor, (3) radial peaking factors, and (4) the VHP trip setpoint.

Reference 15 concluded that the hot full power case is more limiting than the event initiated from hot zero power. The short duration of this event limits its total energy generation in the fuel and the deposition into the primary coolant system. Thus, the maximum PCS response for this event is bounded by the Loss of Load event (15.2.1 ).

The deposited fuel enthalpy at hot full power bounds that at lower power conditions.

The criterion concerning the average enthalpy is addressed in Reference 15.

The parameters used in the reference analysis<3> for DNBR *related fuel failure bound those for Cycle 11. In particular, excess conservatism exists in the augmented radial peaking factor used for the limiting assembly and in the method used to assess fuel failure (i.e., radial peaking vs. DNBR). Thus, the amount of fuel failure predicted in the reference analysis (i.e.,

14.7 %) bounds Cycle 11 and reanalysis is not required.

15.4.9 Spectrum of Rod Drop Accidents {BWR)

This event is not applicable to Palisades since it is not a BWR.

15.5 Increases in Reactor Coolant System Inventory EMF-92-178 Page 88 15.5.1 Inadvertent Operation of the ECCS that Increases Reactor Coolant Inventory 15.5.1.1 Event Description This event is caused by an inadvertent actuation of the ECCS that results in an increase in the primary system inventory.

The primary challenge is to the primary system overpressurization criteria.

15.5.1.2 Event Disposition and Justification The PCS over-pressurization for this event is controlled by the charging system flow rate capacity and the relief capacity of the primary safety valves. The mass flow (steam discharge) capacity of the three safety valves is significantly greater than the inlet mass flow of the three charging pumps. Therefore, there is sufficient discharge capacity to prevent the primary system from being over-pressurized. No flow is initiated from the HPSI and LPSI due to high primary coolant system pressure.

The previous dispositions concluded that the PCS pressurization for this event is bounded by the Loss of Load event (15.2.1 ). Since the Cycle 11 changes do not result in modifications to the plant configuration (e.g., charging pumps or the relief capacity of the PCS safety valves), the loss of load event remains bounding for this event. The potential boron dilution consequence of this event is bounded by the boron dilution event (15.4.6).

15.5.2 CVCS Malfunction that Increases Reactor Coolant Inventory 15.5.2.1 Event Description A malfunction in the CVCS could result in the inadvertent operation of the charging system pumps. If the letdown system is not operating, the result leads to an increase in the primary system coolant inventory and, potentially, an overpressurization of the primary system and/or a dilution of the primary system boron concentration.

15.5.2.2 Event Disposition and Justification The overpressurization challenge is dependent on the system configuration. The

EMF-92-178 Page 89 changes being introduced for Cycle 11 will not effect the plant configuration. Thus, this event remains bounded by Event 15.2.1, as in previous event dispositions. The potential boron dilution consequence is bounded by Event 15.4.6.

15.6 Decreases in Reactor Coolant Inventory 15.6.1 Inadvertent Opening of a PWR Pressurizer Pressure Relief Valve 15.6.1.1 Event Description EMF-92-178 Page 90 This event is initiated by the inadvertent opening of a pressurizer pressure relief valve or safety valve, which results in the blowdown of primary coolant as steam. The primary system pressure decreases rapidly until the pressurizer liquid is depleted, and then to a pressure determined by the hot leg saturation temperature. Reactor scram occurs on TM/LP well before the pressurizer liquid is depleted during the full power case, thus terminating the challenge to SAFDLs.

This event is primarily considered a depressurization event, but with' a negative moderator pressure coefficient and a positive MTC, the thermal margin will be eroded with increased power, increased coolant inlet temperatures and decreased pressures. In addition, the event can also uncover the core with a decrease in the primary coolant inventory.

This accident is classified as a moderate frequency event (Table 15.0.1-1 ). The TM/LP trip affords protection against violation of the acceptance criteria for this.event as described in Section 15.0.1.1. The systems challenged are redundant; no single active failure in the RPS or ESF will adversely affect the consequences of the event.

15.6.1.2 Event Disposition and Justification The event is principally of concern in the short term because of the DNBR challenge due to depressurization before scram. The depressurization has little effect on core power or primary temperatures.

For non-power operating modes, the stored primary energy is less than that for the rated power case.* Reactor power is limited to levels low enough that no challenge to DNB exists. At full power, this event is a depressurization event in which power, inlet temperature and flow remain essentially the same. The parameters controlling the severity of this transient are the rated PORV flow rate and the PCS low pressure trip setpoint. Because of the increase

in radial peaking, DNBR and peak LHR analyses are required for Reload O fuel.

15.6.1.3 Definition of Events Analyzed EMF-92-178 Page 91 This event was analyzed for MDNBR at full power conditions since margin to thermal limits is minimized. The system response for the full power case was evaluated by PTSPWR2 in Reference 3. The event MDNBR was calculated using XCOBRA-lllC. The assumptions on

  • equipment availability are such that primary syst~m pressure is minimized. If sustained release of primary system coolant occurs, the event is bounded by the small break LOCA analysis<6>.

15.6.1.4 Analysis Results The transient response of the reactor system was calculated using the PTSPWR2 computer program in Reference 3, including plots of key system variables and a sequence of events. The core thermal hydraulic boundary conditions from the PTSPWR2 calculation are used as input to the XCOBRA-lllC code to predict the MDNBR for the event. Based on the peaking factors given in Table 15.0.3-1 for Reload 0 fuel, the bounding MDNBR for this event is 1.587 and the peak pellet LHR is 16.33 kW/ft.

15.6.1.5 Conclusion The 95/95 DNB correlation safety limit is not penetrated by this event. Maximum peak pellet LHR for this event is below the incipient fuel centerline melt criterion of 21 kW/ft. Thus, all applicable acceptance criteria are met.

For sustained mass release from the primary coolantsystem, the small break LOCA analysis<6> is bounding.

15.6.2 Radiological Consequences of the Failure of Small Lines Carrying Primary Coolant Outside of Containment 15.6.2.1 Event Description This event occurs when a small line carrying primary coolant outside of containment ruptures leading to a depletion of primary system coolant and a release of contaminated liquid.

The charging and HPSI systems provide sufficient coolant to replenish that which is lost.

Consequently, no fuel failures would be predicted assuming a reactor trip on low pressurizer

EMF-92-178 Page 92 pressure, TM/LP or Safety Injection Signal (SIS). The radiological consequences are limited by the maximum primary coolant activity level allowed by the Technical Specifications since no fuel failure is assumed to occur.

15.6.2.2 Event Disposition and Justification The Cycle 11 changes will not impact initiating faults leading to the pipe break or the primary coolant activity level, this event will remain bounded by the Reference 6 analysis.

15.6.3 Radiological Consequences of Steam Generator Tube Failure 15.6.3.1 Event Description This incident occurs when a steam generator tube fails c~using a leakage of coolant from the primary system to the secondary system. The leakage may deplete the primary coolant inventory thus reducing the PCS pressure. The tube failure will result in release of fission products from the PCS coolant to the main steam system. The controlling features of the analysis are the tube break size and the magnitude of the radiological source term.

15.6.3.2 Event Disposition and Justification This event is controlled by the NSSS system response. Since none of the changes introduced in Cycle 11 will affect the system response, the conclusions drawn in the Reference 6 analysis remain applicable for Cycle 11. That is the radiological releases for this event are well below the 1 O CFR 100 limits for offsite doses. Thus, no further analysis is required for Cycle 11.

15.6.4 Radiological Consequences of a Main Steam Line Failure Outside Containment (BWR)

This event pertains to BWRs and is, therefore, not applicable to Palisades.

EMF-92-178 Page 93 15.6.5 Loss of Coolant Accidents Resulting from a Spectrum of Postulated Piping Breaks Within the Reactor Coolant Pressure Boundary 15.6.5.1 Event Description A loss of coolant accident is initiated by a breach in the primary system pressure boundary. The event initiators vary from relatively small break loss of coolant accidents (SBLOCA) to complete ruptures of the PCS piping for large break LOCAs (LBLOCA). The limiting features of LBLOCA and SBLOCA analyses are the peak clad temperature (PCT) and, the time at elevated temperature that influence the extent of localized and core-wide zircaloy oxidation reaQtion.

15.6.5.2 Event Disposition and Justification The controlling parameters for the transient are: (1) the initial fuel stored energy, (2) the decay heat, (3) the radial and axial power profiles, (4) the fuel rod-to-PCS coolant heat transfer versus time, and (5) the operating conditions for the ECCS systems. The large break LOCA reference analysis<6) includes radial peaking factors equal to those for Reload 0 (i.e., FrT =

2.04 and FrA = 1.76) and reduced ECCS flow. The changes being made for Cycle 11 are bounded by the' reference analysis; thus, a reanalysis is not required for Cycle 11.

The changes for Cycle 11 will not affect the relative severity between the large break and small break LOCAs. A review of the significant parameters listed in Reference 6 (Table 14.17.2-1) for the small break LOCA indicates that the parameters assumed in the reference small break LOCA analysis bound the corresponding values for Cycle 11, including axial shape. Thus, the small break LOCA does not require reanalysis for Cycle 11.

15.7 Radioactive Releases from a Subsystem or Component 15.7.1 Waste Gas System Failure EMF-92-178 Page 94 15.7.2 Radioactive Liquid Waste System Leak or Failure (Release to Atmosphere) 15.7.3 Postulated Radioactive Releases Due to Liquid-Containing Tank Failures The results of the these events are not dependent on the changes being made for Cycle 11. Therefore, the reference analyses(6) remain bounding for the conditions of this disposition.

15.7.4 Radiological Consequences of Fuel Handling Accident 15.7.4.1 Event Description A fuel handling accident occurs when a fuel assembly is damaged during refueling operations such that fuel rods are ruptured, resulting in a release of radioactivity.

The radiological dose is determined by the inventory of radioactive fission products in the affected fuel rods and the amount of release from the fuel pool and surrounding facility.

15.7.4.2 Event Disposition and Justification The inventory of radioactive fission products is determined by the exposure and power level of the assemblies or fuel rods. The analysis presented in FSAR (Reference 6) assumes that the affected assembly was resident in the core for three full power years with a power of 2650 MWt and a radial peaking factor of 1.65. A fuel pool decontamination factor of 100 was assumed.

For Cycle 11, the core power is 2530 MWt and the peak assembly radial peaking factor is 1.76 for a 216 rod assembly. Thus, the combination of a peak assembly radial peaking factor of 1. 76 and a core power of 2530 MWt is slightly ( < 2 %) more limiting than a radial peaking factor of 1.65 and a power level of 2650 MWt. Also, because of increased exposure for Cycle 11, the fission gas inventory and the internal gas pressure at the time of release could exceed the values used in reference analysis. The release gas pressure could affect the fuel pool decontamination factor. Because of these factors, the fission gas inventory and the fuel pool decontamination factors should be reevaluated for Cycle 11. Consumers Power

Company will provide the results of this evaluation.

15.7.5 Spent Fuel Cask Drop Accidents 15.7.5.1 Event Description EMF-92-178 Page 95 A spent fuel cask drop accident can result in the damage of an irradiated fuel assembly and the subsequent release of radioactivity. The inventory of fission products is determined by the exposure and power level of the damaged assemblies.

15. 7.5.2 Event Disposition and Justification Reference 6 contains an analysis of the radiological consequences of this event. The FSAR analysis conservatively assumes that the assembly with the maximum exposure is damaged. A radial peaking factor of 2.0 and a core power level of 2650 MWt are assumed in the Reference 6 analysis. For Cycle 11, the core power is 2530 MWt and the peak assembly radial peaking factor is 1.76 for a 216 *rod assembly. These parameters are bounded by those assumed in the reference FSAR analysis. Like the Fuel Handling Accident (Event 15.7.4), the fission gas inventory and the fuel pool decontamination factors should be reevaluated for Cycle 11 because of increased exposure.

Consumers Power Company will provide this evaluation.

EMF-92-178 Page 96 4.0 References

1.

Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants, NUREG-0800, LWR Edition, U.S. Nuclear Regulatory Commission, Office of Nuclear Reactor Regulation, July 1981.

2.

Advanced Nuclear Fuels Corporation Methodology for Pressurized Water Reactors:

Analysis of Chapter 15 Events, ANF-84-73(P)(A), Revision 5, Appendix B and Supplements 1 and 2, Advanced Nuclear Fuels Corporation, October 1990.

  • 3.

Palisades Cycle 9: Analysis of Standard Review Plan Chapter 15 Events, ANF-90-078, Advanced Nuclear Fuels Corporation, September 1990.

4.
5.
6.
7.
8.
9.
10.
11.
12.

Disposition of Standard Review Plan Chapter 15 Events for Palisades Cycle 9, ANF 041, Revision 2, Advanced Nuclear Fuels Corporation, September 1990.

Application of Exxon Nuclear Company PWR Thermal Margin Methodology to Mixed Core Configurations, XN-NF-82-21 (A), Revision 1, Exxon Nuclear Company, September 1983.

Palisades Final Safety Analysis Report, Updated Version (through Revision 14),

Consumers Power Company.

Palisades Plant Technical Specifications, Consumers Power Company, Appendix A to License No. DPR-20.

Review and Analysis of SAP Chapter 15 Events for Palisades with a 15 % Variable High Power Trip Reset, ANF-90-181, Advanced Nuclear Fuels Corporation, November 1990.

Departure from Nucleate Boiling Correlation for High Thermal Performance Fuel, ANF-1224(A) and Supplement 1, Advanced Nuclear Fuels Corporation, April 1990.

Justification of the ANFP DNB Correlation for High Thermal Performance Fuel in the Palisades Reactor, ANF-89-192(P), Advanced Nuclear Fuels Corporation, January 1990.

Computational Procedure for Evaluating Fuel Rod Bowing, XN-NF-75-32(A) and Supplements 1-4, Exxon Nuclear Company, October 1983.

13.

Description of the Exxon Nuclear Plant Transient Simulation Model for Pressurized Water Reactors (PTS-PWR), XN-NF-74-5(A), Revision 2, Exxon Nuclear Company, October 1986, and Supplements 3-6.

XCOBRA-lllC: A Computer Code to Determine the Distribution of Coolant During Steady-State and Transient Core Operation, XN-NF-75-21 (A), Revision 2, Exxon Nuclear Company, January 1986.

EMF-92-178 Page 97

14.

Palisades Large Break LOCNECCS Analysis with Increased Radial Peaking and Reduced ECCS Flow, EMF-91-177, Siemens Nuclear Power Corporation, October 1991.

15.

Palisades Cycle 11 Safety Analysis Report, EMF-92-177, Siemens Power Corporation, December 1992.

16.

XTG: A Two Group Three-Dimensional Reactor Simulation Utilizing Coarse Mesh Spacing (PWR Version), XN-CC-28(A), Revision 3, Exxon Nuclear Company, January 1975.

17.

Palisades Modified Reactor Protection System Report: Analysis of Chapter 15 Events, ANF-87-150(NP), Volume 2, Advanced Nuclear Fuels Corporation, June 1988.

18.

"Determination of Palisades Thermal Margin/Low Pressure Trip Coefficients",

Combustion Engineering, Inc., September 1971.

19.

Palisades Modified Reactor Protection System Report: Disposition of Standard Review Plan Chapter 15 Events, ANF-87-150(NP), Volume 1, Advanced Nuclear Fuels Corporation, June 1988.

20.

Palisades Cycle 11 Principal Plant Parameters, EMF-92-183(P), Siemens Power Corporation, to be issued.

21.

Palisades Cycle 1 O: Disposition and Analysis of Standard Review Plan Chapter 15 Events, EMF-91-176, Siemens Nuclear Power Corporation, October 1991.

l

EMF-92-178 Issue Date: 12/21/92 PALISADES CYCLE 11: DISPOSITION AND ANALYSIS OF STANDARD REVIEW PLAN CHAPTER 15 EVENTS Distribution CR Baccus TR Barnes SE Cole RA Copeland JW Hulsman CJ Lewis TR Lindquist LA Nielsen CJ Volmer CPCo/HG Shaw (20)