DESCRIPTION OF THE EARLY MARNING SYSTEM FOR THE MASHINGTON PUBLIC POMER SUPPLY SYSTEM NUCLEAR PLANTS 1

AND 2 Revision 2

January, 1985 8502200363 850213 PDR ADOCK 05000397 F

Table of Contents I.

Introduction II.

Mashington Nuclear Projects 1

and 2 Emergency Planning Zone Population III.

Early Marning Notification Process IV.

Tone-Activated Radios V.

Siren System Description VI.

System Maintenance VII.

System Testing VIII.

References Appendices I.

Emergency Broadcast System Radio, Specifications II.

Siren Specifications III. Siren Radio Control Specifications

FIGURES Figure 1:

Ten mile Emergency Planning Zone.

Figure 2:

Population within the 10 mile Emergency Planning Zone.

Figure 3:

Distribution of transient population within 10 miles of site.

Figure 4:

Siren/Emergency Broadcast System coverage contours.

Figure 5:

EBS Tone Activated Radio Receiver.

G Figure 6:

Typical solar siren installation.

C 7

~

p A

I.

INTRODUCTION This document describes the Early Marning System for the Mashington Public Power Supply System's Nuclear Plants 1 and 2 Ten-Mile Emergency Planning Zone.

The Early Marning System will be utilized as described in the Mashington Public Power Supply System's MNP-1 and 2 Emergency Preparedness Plan.

The early warning system is based on a study performed by the Supply I

System using the CRAG II computer code and probabalistic analysis methods to assess the risk and benefit.

The study is titled, "Asses'sment of Emergency Early Marning at Mashington Public Power Supply System Hanford Site", and is dated October 1982.~

~

Due to the plants being located on the Hanford Reservation, the popula-tion is extremely low within the 10 mile zone.

Mith this low population, the study demonstrated that effective notification within the Emergency J

Planning Zone could be performed by a combination of Emergency Broadcast System radios, U.S. Coastguard clearing the Columbia River, Benton County Sheriff clearing the Yakima River, and two sirens located within five miles of the plant on the Columbia River.

This early warning system described herein has already been submitted, reviewed and approved by the NRC.~

~

Oy

~

C N

II.

WASHINGTON NUCLEAR PROJECTS 1

AND 2 EMERGENCY PLANNING ZONE POPULATION The Washington Public Power Supply System leases 1089 acres of land on the Hanford Reservation, located north of Richland, Washington, and con-trolled by the Department of Energy.

The reservation covers an area of approximately 570 square miles, consisting mostly of semi-arid land.

The land leased by the Supply System is approximately 3 miles west of the Columbia River and 12 miles north of the populated area of Richland.

o Population Estimates Figure 1 is a map of the Ten-htile Emergency Planning Zone.~

~

This Ten-thile Emergency Planning Zone is the area for which the Early Warning System has been designed to cover.

Figure 2 presents the compass sector population estimates for 1984.

Estimates were made relative to the center of the triangle formed by the three reactors.

These figures were taken from the MNP-2 Envi-ronmental Report~

~ Operating Li'cense stages, Amendment 85 where references and bases are given.

These figures have been revised to reflect current values and obtained from a population survey con-ducted by Benton County.

The transient industrial workers on the Hanford site have been updated by the appropriate facilities.

o Permanent Residents Permanent residents included all people residing in the area but excluded occupants of institutions.

The ten-mile radius around the site is shown in Figure l.

In 1984, an estimated 2,147 people were living within the Ten-Mile Emergency Planning Zone.

The nearest inhabitants occupy farms which are located east of the Columbia River and are thinly spread over five compass sectors.

There are no permanent residents located within three miles of the site.

Only about 90 persons reside between the three-mile and the five-mile radii; these are all located east of the Columbia River.

y r

I

~ r~

I 1

1

Of the 2,147 people residing in the 10-ttile EPZ, about 1,718 live in Franklin County and about 429 in Benton County.

None of the resi-dents live in incorporated cities.

There are no significant changes in land use expected in Franklin County over the next several years

and, as it is currently irrigated to about the maximum amount practicable, little population increase is foreseen.

No significant change in land use on the Hanford Reservation is expected, and no foreseeable population will reside there; however, the'nincorporated area near the Horn Rapids 0am on the Yakima River in the SSW sector is expected to be the primary growth area within the 10-Mile EPZ.

Population growth within this area is projected to be about six percent per annum.

o Transient Popul ations The transient population is divided into three main subgroups:

1) industrial employees,
2) migratory agricultural, workers, and
3) sportsmen.

Figure 3 illustrates this population location graphically.

Industrial employees in the Ten-Nile EPZ total 8,648.

Most of the employees will be located in Benton County and will form the main population to be evacuated, outnumbering the permanent residents by about 4:1.

About one-tenth of the industrial employees will work at MNP-1, MNP-2, MNP-4 and at the Plant Support Facility.

The projected size of this work force (approximately 1,000) varies considerably with time; as many as 12,000 workers were employed in June 1981 prior to the slowdown of construction at MNP-1 and the termination of MNP-4, but the-figure in September 1982 was down to nearly 5,000.

Oy 9'j t

Current Industrial Em loyment in the 10-Mile EPZ 1

WHP-1 2

WHP-2 3

WHP-4 4

Plant Support Facility 5

Supply System Downtown Complex 6

DOE 300 Area 7

DOE, 400 Area, FFTF, Fast Flux Test Facility 8

DOE 1100 Area, Bus Lot, Stores 9

DOE 1200 Area, J.

A. Jones 10 DOE 3000 Area, Pacific Northwest Laboratory 11 EXXOH, Horn Rapids Road Facility 12 Others workers TOTAL 76 772 18 126 338 2,532

'773 660 200 2,003 800 350 8,648 The majority of these employees work days, but there are a signifi-cant number of workers assigned to some shift work.

Therefore, the industrial planning figure of 8,648 to be evacuated is conservative.

There are up to approximately 3,346 migratory farm workers in the Ten-Mile Emergency Planning Zone.

This figure may be high due to the possibility of double counting during the different harvest periods.

The peak season for these workers is May and June; the next highest employment season is during the fall harvest.

These workers consist of both permanent and temporary residents of the Tri-Cities area, some living within the Ten-Nile Emergency Planning Zone.

The numbers shown on Figure 3 reflect their work locations in Franklin County within the Ten-Mile Emergency Planning Zone, not their residences.

Sportsmen, consisting of hunters, fishermen, and boaters, enjoy activities mainly along the east bank of the Columbia River.

The primary fishing season is. from June thr ough Hovember; the main hunt-ing season being October through January.

The heaviest use of the area by sportsmen is on weekends and holidays in the early morning hours.

On the average, 50 fishermen and 10 hunters are present in

Oy y

)y

)

'I

Franklin County during the weekdays.

This increases to about, 100 fishermen and 50 hunters on weekends and holidays.

Sportsmen also use the Yakima River, with an estimated maximum of 50 at any time in this area.

Ouring peak fishing or hunting times, up to 1,050 sportsmen may be located within the Ten-Mile Emergency Planning Zone.

4

")~

The main concentration of sportsmen consists of fishermen located just south of the Ringold Fish Hatchery spillway on 'the Franklin County side of the Columbia River.

Hunting consists of both water-fowl (hunted at the Wahluke Hunting Area on the Franklin County side of the Columbia River) and upland game birds (hunted inland on the farmland of Franklin County).

Four hundred sportsmen may be located around the Ringold Fish Hatchery and the Wahluke Hunting Area an'd the rest distributed inland.

Of these, 1,000 are assigned to Franklin County and 50'to Benton County.

An additional recreation attraction has been created in the south section of the~Ten-Mile Emergency Planning Zone in Benton County.

An off-road vehicle -park has been developed, as many as 500 participants/spectators may be present during an event.

o S ecial Po ulation There are no individuals within the Ten-Mile Emergency Planning Zone confined to institutions such as hospitals, nursing

homes, or penal institutions.

There are three schools, the Edwin Markham Elementary School, the Cypress Gardens School and the County Christian Center, with a total enrollment of approximately 365 students and staff.

Although most of these students live within the Ten-Mile Emergency Planning Zone, the total amount was added to the population for this study.

~I 0~

V t I l

III. EARLY WARNING NOTIFICATION PROCESS The approach taken by the Supply System in designing the Early Warning System for the Washington Public Power Supply System's Nuclear Pro-jects 1

and 2 is based on a study(") and correspondence(

submitted to the Nuclear Regulatory Commission (NRC) and approved as meeting the intent of the NRC requirements.(1

)

The emergency shall be classified by the Plant Emergency Director as soon as an off-normal event occurs that corresponds to one of the initiating conditions.

Each class is defined in such a manner so that emergencies can be classified either up or down, depending on whether the emergency becomes more or less severe.

When there is doubt as to the classifica-tion of the emergency, the more conservative class shall be used.

After classifying the emergency, the Plant Emergency Director will initiate notification of emergency personnel.

The extent of the notification will depend upon the emergency classification.

Initial emergency notification to nearby Supply System plants, the State,

County, and the Department of Energy will be made through the Security Communications Center.

Both phone lines and radio communications are available.

The nearby facilities will implement the necessary emergency actions.

In the event of an emergency requiring protective measures to be taken at the nearby facilities, the Recovery Manager at the Emergency Operations Facility or the Plant Emergency Director will give specific instructions.

Notification of the County Emergency Dispatch Center and Benton County Emergency Management in Kennewick, Department of Energy, and the Washington State Department of Emergency Management (State Emergency Operations Center) will be by dedicated phone lines.

Notification to the Nuclear Regulatory Commission in Bethesda, Maryland, will be made via the NRC dedicated phone network from the Control Room.

The Nuclear Regula-tory Commission offices in Bethesda will patch the call through to the

~0

'I I

J'p Y

I 1

% II

'I a,

~0 Nuclear Regulatory Commission offices in Region V, Walnut Creek, California.

Notification of all other offsite emergency agencies will be made hy telephone.

Radio provides backup communications to the County Emergency Dispatch Center and Department of Energy-RL.

Activation of the Early Marning system is the responsibility of the Benton/Franklin Counties Department of Emergency Management Director.

The Early Marning System is designed to provide both an alert signal and information to the population on an area-wide basis throughout the Ten-Mile Emergency Planning Zone.

Two means have been established by the Supply System for notification of the public.

For residents within the Ten-Mile Emergency Planning Zone the tone activated radios provide the

'rimary means of notification.

These radios. are activated by the Emer-gency Broadcast System signal and provide instructions for protective actions.

The system is designed to be operable within 15 minutes of a decision to activate the system.

Notification of transient population along the Columbia and Yakima rivers is provided by the Coast Guard and by local law enforcement

agencies, respectively.

Two sirens are located along a segment of the Columbia River to help expedite Coast Guard evacuation of the river (Figure 4).

Activation of the sirens should reduce the need for Coast Guard person-to-person interactions along the Columbia River upstream from the MNP-2 pump house for about two (2) miles.

This 'is -the segment of the river that is most utilized by the public. It is estimated that notification of transients along the Columbia River can be accomplished within three (3) hours.

Notification of transients along the Yakima River is the responsibility of the Benton County Sheriff.

Through cooperative agreements under emergency conditions, the Sheriff can call. upon other law enforcement authorities to perform various tasks.

Primary use areas of the Yakima River are adjacent to Highway 240.

Users will be informed as a peri-pheral task in the process of controlling use of State Highway 240, which will be done hy the law enforcement officers in the vicinity at the time

OO I

I g I

~$ '~1 I

I' ft II

However, it is likely that =people not initially alerted by the siren signals or the tone-activated radios will eventually be alerted by TV, radios (not of the tone-activated type), and other informal means, including telephone calls from neighbors, friends, relatives, and word-of-mouth.

In addition, the initial activation of the Early Marning System would be followed by subsequent activations to ensu're that the total population was alerted.

In conclusion, this report describes an early warning system and process which provides effective early notification,to population groups located within the 10 mile Emergency Planning 2one and which is consistent with commitments set forth in our previous submittals to the Nuclear Regula-tory Commission.~

~

The technical basis for the adequacy of the system is. documented in a report entitled "Assessment of Early Marning at Mashington Public Power Supply System Hanford Site, R.F. Haight, October, 1982.~

Utilization of this early warning approach was previously approved by the Nuclear Regulatory Commission, February 14, 1983.~

~0 Oy 1

1 4r 5

1 T

Mhen the receivers are not used for receiving emergency information, they may be used to receive the normal KONA programming.

Receivers used in this way provide items of considerable day-to-day value to residents, being, in effect, a free radio with one channel of program material.

When the programmed. material can be received 'at any time, the resident is also reassured that his receiver is in good working order.

The need for frequent testing is thereby eliminated, minimizing annoyance and anxiety to residents.

Distribution of the tone-activated radios is conducted through a coordi-nated effort between the Benton and Franklin County Department of Emergency Management and the Supply System.

In order to maintain a thorough and complete coverage of the area, various approaches are being used by the Supply System and the Benton County Department of Emergency Management to keep up-to-date records of persons moving into the Ten-Mile Emergency Planning Zone.

These are:

o Public Utility Districts o

Post Office route carriers o

County Auditors o

Recanvassing of the area The primary method will be through the Public Utility Districts and the Post Offices.

The alternate approach.will be through the County Audi-tor's Office or, if need be, recanvassing the area.

An additional mechanism is the mail returns of a quarterly information newsletter sent to all residents within the 10-mile Emergency Planning Zone.

The returned newsletter is an indication of a resident's change.

OO Oy

~ I 1

I C

E l

V.

COAST GUARD RESPONSE The United States Coast Guard maintains river control capability at the City of Kennewick.

Agreements and procedures are in place for closing and clearing the river of recreationists.

The Department of Energy jet boats are available to assist.

Automatic closure of the Columbia River occurs during a General Emergency classification.

All other closures are at the request of the Supply System's Recovery Manager.

River closure boundaries are from the Old Hanford Townsite to the north to Leslie Groves Park to the south.

Arrangements have been made with Benton County Sheriff to transport a Coast Guard representative to the Old Hanford Townsite to meet the Department of Energy boat and an environmental monitor.

A Supply System or Washington State environmental monitor will meet the Coast Guard boat at Leslie Groves Park.

VI.

SIREN SYSTEM DESCRIPTION The siren system consists of three pole mounted, 122 db, electronic, omnidirectional sirens.

Siren locations and estimated coverage is shown on Figure 4.

Each uni is battery powered with solar cells or AC power, that is used to keep the batteries at full charge.

Initial experience resulted in cold weather failures.

Corrective actions are being imple-mented to assure operability.

In addition, each sirens'atteries are capable of being recharged by external vehicular chargers, if necessary.

All electronics, power and control equipment is housed within a weather-proof, pole mounted steel enclosure.

The sirens and their associated equipment mount to Class II cedar poles designed to withstand wind load-ing in excess of 100 mph.

The poles are guyed and the area at the base of the pole is graveled for fire protection.

Each siren has an appropri-ate sign warning of the danger of its high sound levels.

The siren control system is a Remote Data Acquisition/Control System that is used for transmitting alarm or status messages between the master sta-tion and remote stations.

The system uses UHF radio as the communica-tions link.

The Data Acquisition/Control System consists of a master station and remote status and control units as follows:

Ot Oy

~I e,

IX.

REFERENCES 1.

Washington Public Power Su ply System Emer ency Pre aredness P'lan, Mashin ton Nuclear Projects 1, 2, and 4.

2.

WNP-2 Environmental Re ort - 0 eratin License Sta e Amendment 85, July 17, 1981.

3.

Hanford Site Evacuation Time Assessment

Study, September 1981.

4.

Criteria for Pre aration and Evaluation of Radiological Emergency Res onse Plans and Pre aredness in Su ort of Nuclear Power Plants, NUREG-0654, FEtQ-REP-l, Rev. 1, October 1980.

5.

Outdoor Marnin Systems

Guide, CPG1-17, March 1, 1980.

6.

Handbook of Noise Measurements, Arnold P.

G. Peterson, Copyright 1980.

7.

Assessment of Emer ency Earl Warning at Washin ton Public Power Su ly S stem Hanford Site, R. F. Haight, October, 1982.

8.

Letter:

From Robert L. Fer usen, Mana ing Director Washin ton Public Power Su 1

System, to Milliam J. Dircks, Executive Director of Operations NRC, Washin ton D.C., dated November 8, 1982.

9.

Letter:

From Robert L. Fer usen, Mana in Director Mashin ton Public Power Su ly S stem, to William J. Dircks Executive Director of 0 erations NRC Mashin ton D.C., dated January 17, 1983.

10.

Letter:

From William J. Dircks, Executive Director of Operations NRC Washin ton D.C., to Robert L. Fer uson Mana in Director Washin ton Public Power Su 1

System, dated February 14, 1983.

11.

Siren E ui ment Haintenance, Communications Service Instruction, CSI 6.11.

12.

f4aintenance

Schedule, Communications Service Instruction, CSI 2.4.

y C

~r II

y APPENDIX I Emer enc Broadcast System Radio S ecifications j.

SCDPE To provide seller a description, technical specifications, and testing criteria for tone-activated Emergency Broadcast System radios.

II.

INFORMATION o

Required Delivery Date:

April 1, 1982 o

Instructions:

All materials shall be free from defects and imperfections which might affect the appearance, operation, or serviceability of the finished product.

III. SPECIFICATIONS o

Frequency Range:

The radio shall operate in the Commercial A.M.

Broadcast,

Band, 525 KHz to 1600 KHz.

o Operating Channel:

The radio shall be a single-channel

receiver, crystal controlled.

Operating frequency shall be 610 KHz.

o Receiver:

~t "i:

i" 1<<2 b /I minimum.

Selectivity:

25 db 9 9 KHz.

Frequenc Stability:

.0025% -10 to +50 C.

~ 0 y

e j1,

o Decoder:

Hum and Noise:

50 db (at 1 micro volt input).

~

'he radio shall be capable of decoding the Stan-dard Emergency Broadcast System two-tone atten-tion signal.

Upon receipt of the EBS tone, the Decoder shall emit an audible alert tone for a minimum of five (5) seconds and activate an indicator light.

The indicator light shall remain on until manually reset.

o Monitor/Mute Control:

The radio shall provide to the user the option of monitoring the channel or, by push-button con-trol, completely mute the radio.

Unit shall automatically unmute upon reception of the EBS tones.

o Volume Control:

Audio output shall be user adjustable.

Minimum audio level shall be internally adjustable.

o Audio Output:

Maximum audio output shall not be less than 90 db at 12" from the front of the unit.

Tester shall use a 1000 Hz tone, modulating the carrier at not more than 100%.

o Antenna:

The antenna shall be built into the cabinet.

o Speaker:

The speaker shall be built into the cabinet.

o Power Source:

AC/DC, the unit shall operate on built-in rechargeable batteries (supplied with the kit).

Battery duty cycle shall be six (6) hours, mini-mum, in the unmuted condition.

01 I

y 1

f th

o Battery Charger:

Battery charger shall operate on 115 volt, 60 Hz, A.C. power.

It shall be capable of operating the radio without batteries.

Charger may be internal or external to the radio.

If external, it must be UL approved.

Charger shall completely recharge dead batteries in six-teen (16) hours with the radio on and in the unmuted condition.

Battery charger shall be furnished with an undetachable A.C. power cord not less than six (6) feet long.

o Cabinet:

Unit shall be desk-top mountable equipment with mar-proof feet.

Size:

Not to exceed 8" x 9" x 4".

Finish:

Unit must be attractive'ly finished in an onobtrusive color.

~Wef ht:

Not to exceed seven (7) pounds.

Controls and Indicators:

All controls must be easily accessible from the top or front of the unit.

All controls must be clearly labeled.

Construction:

High-impact plastic, as a minimum.

o Certification:

Unit must be certified by the. FCC under Part 73.941 of the FCC Rules pertaining to EBS decoder devices.

<<1 1

~p ll'

o Literature:

Seller shall provide operator instructions with each unit, plus 100 each extra copies.

Seller shall provide three (3) each complete sets of maintenance literature.

Yaintenance manuals must include circuit schematics, circuit board layout, theory of operation, and a c6mplete parts breakdown with part numbers.

Seller shall provide spare parts breakdown with unit cost and availability as part of his bid response.

o Life Expectancy:

Calculated Mean Time Between Failure (NTBF) l

~

~

shall be 50,000 hours0 days <br />0 hours <br />0 weeks <br />0 months <br /> minimum; seller shall provide rationale used to determine HTBF.

o Warr anty:

Seller shall warrant each unit to be free from defects in material and workmanship for a period of ninety (90) days after'receipt Seller will replace or repair the product at no charge to the buyer during the 90-day period..Seller will pay any shipping charges incurred'for the reason of warranty repair.

Seller shall warrant parts for a period of one (1) year after receipt of units.

<<21-

l l't

APPENDIX II Siren S ecifications 1.

SCOPE This specification provides for the purchase of two separate types of sirens.

The basic difference between the Type I and the Type II siren is the power supply.

Type I is to be a self-powered unit; Type II will be a

commercially powered unit.

The Supply System intends to purchase seven (7) each Type I sirens and seven (7) each Type II sirens.

The Seller shall design and supply a complete, ready-to-install-and-operate unit for either Type I, Type II, or both types of sirens.

The seller is not required to provide radio control equipment or siren pole.

The bid should include accessories such as siren mast, conduit, electrical enclo-

sures, etc.

The Supply System will provide radio control equipment and pole.

II.

DESIGN REt1VIRENENTS, BOTH TYPES o

Genera1 Sirens are to be used in an outdoor warning system and should be constructed such that dust collection, water collection, and water condensation will be minimized.

Siren Systems shall be of rugged construction so as to withstand self-induced vibration and exposure to severe weather conditions without excessive deterioration'and shall be instantly and dependably operable after long periods of nonuse.

Openings shall be suitably protected to restrict entrance of birds or small insects.

22

I ii I

o Material s tlaterials not definitely specified shall be of the best commercial quality suitable for this purpose.

All materials shall be free from defects and imperfections which might affect the serviceability of the finished product.

All parts subject to corrosion shall be fab-ricated of corrosion-resistant material or suitably treated to resist corrosion.

o Control Cabinets.

Control cabinet fronts should be removable and secured to -the cabi-net with hinges.

Cabinet fronts should be sealed with a moisture-resistant neopreme gasket permanently secured to the door frame.

Cabinet surfaces should be bonderized or phosphatized, sprayed with a nonferrous primer and activator, and finished with an aluminum-vinyl paint or equivalent to ensure protection from corrosion.

o Notors All motors and/or motor enclosures should be of a suitable weather-proof design to provide reliable operation under the required envi-ronmental conditions.

Bearing enclosures should be designed to prevent the entry of contaminants and lubricants chosen for extreme temperature conditions so as to prevent the necessity of frequent maintenance.

(Sealed lifetime bearings are preferred.)

o Environmental The siren system will be designed to operate within the following ambient environmental conditions:

23

4 e

lt I

k h

Temperature Relative Humidity Altitude Ice Loading Mind

-25'F to 120'F 0 to 95 400 to 1000 feet 0 to 2 inches 0 to 125 mph Equipment housing that cannot be pole mounted shall be designed for direct burial.

o

~Nountin Sirens shall be suitable for mounting on top of a Class II cedar pole.

Sirens shall be supplied complete with mounting hardware.

o Bolts, Pins, Etc.

All screws,

pins, and bolts, shall be installed with a positive means of protection against their working loose due to vibration.

o Melds Meld connections shall be continuous; spot welding of sheet metal is not permitted.

o Paint All parts to be painted shall be thoroughly cleaned according to the paint 'manufacturer's specification.

All surfaces shall be painted with metal etch primer and at least two (2) coats of weather-resistant paint.

Paint color to be 8attleship Gray.

L I

k

'l

III. PERFORMANCE, BOTH TYPES Each siren shall be capable of providing an alerting signal with a minimum of 122 db(c) at any point at ground level, assuming a 50-foot, above-ground installation.

The alerting signal shall be a steady "on" tone within a frequency range of 200 Hz to 500 Hz radiated omni-directionally.

Sound output shall not decline more than 2 db(c) below full rated output during the three-minute alert signal.

IV.

LOCAL CONTROLS BOTH TYPES o

Each siren shall have controls to activate all required and appro-priate siren functions from the siren location.

o Once activated, the siren shall automatically deactivate after three minutes and automatically reset.

o Siren test.

o Siren off.

V.

REMOTE CONTROL INTERFACE, BOTH TYPES Each siren shall be capable of being remotely activated,

operated, and monitored by a radio-controlled system (supplied and installed by the Supply System).

All control functions shall be accessible through a

radio control interface.

The following signals will, as a minimum, be applied by the radio control system to the radio control interface to activate the specified function.

'o Siren "Alert" Signal On - A momentary contact which will start the three-minute "alert" signal.

I I )

o Siren Cancel - A momentary contact closure which will stop the siren signal before the three-minute period has elapsed.

o Bidder shall specify all necessary additional control functions up to a total quantity of four (4).

VI.

RE/'lOTE STATUS INOICATIONS, BOTH TYPES Each siren will be capable of remotely indicating status of siren func-tions through the radio control system by means of contact closures at the radio control interface.'idder shall specify necessary status points up to a total quantity of four (4).

VII. POKIER SUPPLY, TYPE I SIREN o

The Type I siren unit shall be capable of providing the three-minute alert signal at least four (4) times per day.

The siren unit need not provide more than 10 three-minute alert signals in a five- (5) day period.

Recharge of the siren unit power supply shall be automatic.

o Type I siren shall provide input power to the radio control system.

This radio equipment requires 6.0 amp hours at 12 VDC per day.

Fuel tank, if required, shall be of a sufficient size to provide 1.3 years of fuel minimum, assuming one 30-second test each month, ten three-minute activations, diesel exercise time, radio control system load, and battery recharge time.

E

'I

~

'III.

POllER SUPPLY TYPE II SIREN The Type II siren shall be electrically powered and shall operate on a maximum of 480V, three-phase, 60 Hz alternating current.

Duty cycle shall be continuous once activated; however, siren shall automatically deactivate after three (3) mi,nutes.

IX.

FACTORY ACCEPTANCE TEST Seller shall perform an acceptance test prior to shipment.

Buyer shall review and approve factory acceptance test procedure (ATP) prior to the ATP being performed.

Buyer shall have the option of observing the fac-tory acceptance test.

X.

DOCUMENTATION FURNISHED BY SELLER o

'Each document submitted by the Seller shall be clearly identified by the Purchaser's name and purchase order number, the equipment description, specific identification, and the manufacturer.'s name and address.

o The seller shall provide the followingwithin 30" days after receipt of order.

a.

A production schedule showing hold and inspection points.

Buyer may, at its option, witness and approve any and all inspections.

b.

One sepia and three prints of all drawings.

The Buyer reserves the right to reproduce arly and all drawings or prints received that-it considers necessary for maintenance, despite any notice prohibiting the same appearing on the drawings or prints.

27

,li

c.

Eighteen (18) copies (nine (9) each of Type I, nine (9) each of Type II) of their installation, operating, and maintenance manual for each type of siren provided.

The equipment manual should include the following:

0 Section 1 - General Description Section 2 - Installation Section 3 - Theory of Operation Section 4 - Calibration o

Section 5 - Preventative Maintenance o

Section 6 - Corrective Maintenance o

Section 7-o Section 8-Drawings and Wiring Diagrams Parts Identification d.

Three (3) copies of the Seller's recommended spare parts list for each type of siren.

All parts listed shall be categorized as Parts Common and Parts Peculiar.

Parts include those parts which are considered unique and are not commonly available from local sources.

e.

Three (3) copies of the proposed factory acceptance test proce-dure for the siren systems and three (3) copies of the approved Acceptance Test Procedure.

Three (3) copies of the results (data sheet or report) of the Acceptance Testing of each siren.

f.

A technical installation specification and a post installation acceptance test procedure.

These will be used by the Buyer to write an installation contract.

F 1

XI.

TRAINIHG AND SPARE PARTS Seller shall provide maintenance training for eight (8) members of the Buyer's maintenance staff at the Buyer's location.

Training shall take place not more than sixty (60) days after delivery of siren equipment.

Bidder shall provide a recommended spare parts list.

Spare parts prices shall be quoted as separate line items.

XII. WARRANTY Bidder shall specify warranty offered with equipment.

XIII. MEAN TIME BEFORE FAILURE Bidder shall provide Mean Time Before Failure (MTBF) information for each siren system.

XIV. BID EVALUATION The Buyer intends to purchase sirens from the Bidder or Bidders who meet all of the requirements of the preceding specifications in accordance with, but not limited to, the following criteria:

Completeness of Design Cost Effectiveness Operating and Maintenance Cost Control and Monitor Interface Delivery Installation Requirements Simplicity of Design Warranty Mean Time Before Failure l'

r 1'

8 l II

XV.

EXCEPTIONS If the Bidder takes any exception to this specification, the exception shall be itemized and described in detail and included as an integral part of the proposal.

Any exception may result in the rejection of the bid.

e cJ J

rr

'I f

1 I

APPENDIX III Siren Radio Control S ecifications I.

REMOTE STATION Each Status and Control Unit shall be capable of two-way communi-cations with a Master Station and shall be capable of reporting up to four (4) input conditions (Status Points) plus a Test Indication.

The inputs shall accommodate a dry-contact closure.

~be posi-tion of this dry contact will be maintained during the unit's transmission; the unit shall report the status of this input.

The input circuit shall operate with an input -loop resistance of up to 3000 ohms.

Transient protection shall be provided for all external inputs in accordance with the IEEE Surge Withstand Capability Recommendations (ANSI C37.90a).

The equipment shall be protected against damage from high-voltage transients; false messages shall not be reported as a result of these transients.

The unit shall report all of its information upon reception of an interrogation message from the Master Station.

An interrogation shall initiate a program of redundant trans-missions.

Each transmission shall take no more than two (2) seconds.

Message redundance shall be programmable fr'om one (1) to at least three (3) transmissions per interrogation.

-31>>

Each Status and Control Unit shall accept an interrogation message from the Master Station.

This interrogation message shall cause transmission (not more than two (2) seconds long) of all the Status and Control Unit's information.

A special test switch shall be provided to permit the trans-mission of a Manual Test Message.

The Test Transmission shall transmit all of the Station's information, plus a unique Test Message Indication.

o Address Each Status and Control Unit shall have a unique address.

This Station address shall be user changeable.

2.

Control Section The Control Section shall be supplied with a minimum of four (4) control relays.

Relays shall be momentary-contact closure (one- (1) second closure).

One (1) command function shall operate one (1) relay.

The Control Section shall respond to commands directly addressed to it; it shall also respond to commands addressed to all Remote Units.

The following types of Output Relay Closures shall be possible:

Momentar -Contact Closure (one- (1) second closure)-

One (1) command function shall operate one (1) relay.

32

-V

latched-Contact Closure - 0ne (1) command function shall operate one (1) relay.

It shall be possible to combine different types of relay actua-tions in the same unit, as determined by individual jumpers.

All relays shall be plug-in.

Contacts shall be rated at 2 amp, 250 VAC, as a minimum.

Each Status and Control Unit shall transmit an acknowledgement message upon reception of a control command.

Acknowledgement Cshall include station address.

An acknowledgement shall initi-ate a program of redundant transmissions.

A'ime-diversity transmission technique shall be used; i.e.,

each Remote Unit shall have a variable time interval between its redundant transmission.

Construction The Status and Control Unit shall be housed in a 16-GA'teel enclo-

sure, minimum, with a hinged, gasketed door.

Enclosure shall meet NEHA weatherproof specifications as a minimum.

The housing shall measure not more than 36" H x 30" M x 12" D.

The housing shall be sui:table for pole mountings and shall be lockable.

External connections shall be made via a screw-type barrier strip capable of accepting an AMG 814 wire termination.

The equipment shall operate, as specified, over an ambient tempera-ture range of -30 C to +60'C, with a relative humidity of up to 35 percent, noncondensing.

33

i I

~1

/

'I l,

4.

Fourteen (14) Status and Control Units (including radio) shall operate from a D.C. power supply (supplied by Buyer) of 12 VDC + 2 volts.

Status and Control Unit shall provide appropriate input fuse or circuit breaker mounted in or on the Status and Control Unit.

The Status and Control Unit's current requirements from the power supply shall not exceed 250 MA in standby, 800 MA during control functions, and 3 amps during transmission.

II.

MASTER STATION The Master Station shall provide all specified control and display func-tions for fifteen (15)

Remote Units and be capable of expansion to twenty (20)

Remote Units, all within the original Master Station.

The functions that the Master Station shall perform are as follows:

Operator interface via a control panel Message reception Message transmission Data display and hard copy printout 1.

Control Panel Functions The operator Control Panel shall enable the Operator to perform the following functions:

Issue a single command that will activate one function at a Remote Unit or all Remote Units.

Issue manual interrogation requests to individual Remotes.

Lock and unlock the keyboard for commands.

Reset individual alarm displays.

View Remote Station status.

~

A

~ '

o Display and print time of day, optional.

o Reset audible alarm.

o Enable/disable printer.

2.

~M Each Remote Unit's Status Inputs shall be displayed at the Master Station plus Test Message Indicator.

The Master Station shall be able to receive messages from the Remote Units that are replies to interrogation requests.

The Master Station shall decode the Remote Unit's transmissions.

If the message format uses data bits, then the Master Station shall check the validity of each received message.

The Master Station shall provide an indication upon any change in the state of a Remote Station's Status Inputs.

3.

Hessa e Transmission The Master Station shall have expansion capability of transmitting messages to up to twenty (2Q) Remote Station-addresses.

The Master Station shall be equipped for fifteen (15).

There shall be two (2) types of messages transmitted:

commands and interrogation messages.

o Commands Comand messages shall be transmitted to either a specific Remote Unit address or to all Remote Unit addresses.

"Group" commands shall not take more time to program and transmit than commands to individual stations.

8 k

~

Commands shall be issued manually by the Operator.

Manual commands shall require at least two (2) button operations to be transmitted.

The Master Station shall be capable of sending a

minimum of four (4) control commands to each Remote Unit.

o Interro ation Messages The Master Station shall be capable of transmitting manual interrogation messages to individual units.

The Remotes shall respond to the interrogation message by transmitting a cycle of all of its information.

If a Remote Unit fails to answer an interrogation

request, the Master Station shall provide indication of Remote Station failure.

4.

Manual Commands A Control Keyboard shall be provided for manual commands.

A means of locking the keyboard is required; an indication shall be given on the Control Panel to show whether it is locked or unlocked.

A command shall be entered into the Master Station via the key-board.

The command shall be transmitted by pressing a Control Pushbutton and the Send Pushbutton simultaneously for at least

.5 seconds.

A visual display of the operator-programmed control command code is required prior to transmitting the control command.

V

'V

~t I

k

,4 k

I I

A

'I

5.

Data Display The Master Station shall contain a section for displaying Remote Unit Data.

Each display shall be capable of identifying and'dis-playing for each Remote the Station Address, the Status of its Inputs, Station Fail (no acknowledgement),

and Test Indication.

A change in status of any input shall flash an indicator light 'and, in some cases, sound an alarm on the Master Station.

6.

Normal/Alarm -Condition It shall be possible to define a normal and alarm, condition for each Status Input.

These definitions may be co+non for. all corresponding points in the System, i.e., all Status Inputs 83.

III. REMOTE CONTROL INITIATION COMMAND STATION This Station's primary requirement is to turn on and off all sireqs; therefore, its function is to provide control signalling to all'emote Stations.

This Station shall report its status to the Master Station in accordance with Section I of this specification.

This Station will not be controlled from any point nor will it monitor status of any remote point.

However, it must accept interrogation from the Master Station in accordance with Section I of this specification.

The Remote Control Initiation Station shall operate from 120 VAC

+ 20 percent, 60 Hz power.

37

I I

lk I gl

'4 W

1 II I

1l

2.

Construction This Station shall be suitable for wall mounting or desk-top appli-cation.

All circuitry called out in this part shall be housed in one lockable enclosure, with the exception of the Control Keyboard.

The housing shall measure not more than 30" x 30" x 12".

The hous-ing and equipment shall not weigh more than forty (40) pounds.

3.

Front Panel All switches and indicator lights shall be individually color coded.

All switches shall be spring loaded; power-on, power-off switch shall not be accessible from the front panel.

An A.C. power indicator light shall be provided on the front of the unit.

The "Siren-On" command and the "Siren-Off" command are the only command functions required at the Remote Control Initiation Command Station.

A "Siren-On" indicator is desirable, but not mandatory.

IV.

RADIO EQUIPMEHT The System shall use UHF radio as the communications link.

The radio channel to be used is an existing Mashington Public Power Supply System two-way radio channel.

The Siren Control Radio System called out in this specification shall be licensable under'CC Rules and Regulations, Part 90, Subpart J.

The equipment shall be listed on the FCC's current equipment list, "Acceptable for Licensing," and designated for use as an operational fixed station under Part 90.203.

All radio equipment shall be equipped with a Time-Out Timer which will automatically deac'tsvate the transmitter in the event the carrier remains on for more than one (1) minute.

- 38>>

'l II

1.

Remote Station and Remote Initiation Station, Radio The Remote Station radio must be FCC type, accepted for Remote Sta-tion application.

Only subaudible coded squelch shall be used; Seller shall provide digital coded squelch, if possible.

Digital Code 8131 shall be used or Tone Code 110.9 Hz.

Transmitter power shall not be less than 1.5 watts but not more than ten (10) watts (two (2) watts is preferable).

(See radio specification.)

Seller shall provide a

UHF Yagi antenna with at least 10 db of gain and 15 db front-to-back radio.

Antenna shall be supplied with mounting hardware for mounting to a 2" O.D. pipe.

Seller shall provide 70'f transmission line for each station.

Transmission line shall be 1/2" foam-dielectric heliax cable (less than 2 db attenuation per 100').

Antenna, transmission line, and radio shall be supplied with matching co'nnectors.

2.

Master Station, Radio The Master Station transmitter power shall be at least two (2) wa ts but not more than twelve (12) watts.

The radio shall be external to the Master Station and capable of control from the Master Station at a distance up to 100 feet.

Receive audio, desk microphone, and push-to-talk shall be provided to the Operator at the Master Sta-tion.

All other requirements are the same as the Remote Station Radio.

3.

Radio S ecifications The radio shall meet or exceed the following:

o Frequency Stab)lity

+.005% -20'C to 60'C o

RF Spurious 8 Harmonic Emissions

-60 db C

o Receiver Sensitivity for 20 db guieting o

Intermodulation EIA Sinad o

Selectivity EIA Sinad

.5 UV

-75 db 85 db 9 1000 Hz

+ 3.0 KHz Deviation

,o Audio Output

.5 Matts 1

The radio shall be supplied with a microphone-input and.a microphone-and-receive audio output (a speaker/microphone handset is acceptable).

(NOTE:

This is not a siren system which can be used to broadcast messages over the sirens.)

- 40

C 1

II'

~

I V

+

~ ~

I e

OOOO 1

~

gg f

C

~ 5 le eoooooee

~0 tie' Ce et' ce et pter a)OOOO

~t i

pet

~ $

c St I

t.e

~I

~

at e ~

C

~ MI

~

h iiII I

s blah>jl<='-

Itl 3

g I I )g g Qg~

0

~ v oXa g~o

~R~gh.'.~

jt, al'l If

~

lL Pj j, ~

~ t~tI~it eeoeeeeee CirlleTlat hei tev O O O O O OQ~

r,le C

~Qp I

~>>v

~.

~5 te ceo z~ ~

eeele O.

LX+I tt

, $Pgfi+~~4 fo,art IIehc a

~ IfOOOO

~ 5 vhphle

-hih't e eee e

~

ca, eerahe

~I'. / -.'

rt 5 A'C 6p i P leer@ Prr 1

~e~

CI,)1 rC,

~ t COCQO tr r

Ihtlle e le 'I~ 'Itthlel I't,

~Ieae a

!v'vl 5

,n r.

If'

\\ terat

~tercet I'hvo

~Ah%~

r 5

eoeoef

~f ~

llthttI f~t. g Oee Admit)S" at

~ I epee ol>>

Sft

<< I

~ 'II j

~

ttr th

~

~IrreIj

~e

~O ft oe Vl A

tee O eeeh I

hei Orrida~

WOO eetet J!..

,le I+"

p tel.

I

(~OI I"pVO

.A

~45>>itrtrp<gVp+A I,

~

v ~pe ~n gp(= ytlg lv " 4p'"r~ Ic

'k YFKklW

-a

~

'zc j.t,l)I!

~ 'l.

~ ~re e

Ce FIGURE 1 10 MILEEMERGENCY PLAN ZONE MAP

-,41-84-1075

(

/

l

(

71 425 NW NNW 10 MILES pig

~148 1239 NE WNW 942 ENE 0

W WSW 898 GQ

~24 GH RH

~23 HH

~18

~5 m

~223 Qg

~290

~298 E

1033 ESE 1378 800 SW

~i

~353 KH

~401

~11 5

~es

~69 SE

'l090 SSW TOTALSEGMENT POPULATION 383 0 TO 10 MESS S

1400 SSE 6445 POPULATION TOTALS-[PF~RMA NANT POPULATION TOTALS-RING, MILES 0

2 5

10 RING POPVLATION 90 2057 1OTAL MILKS 0

2 0-$

0 10 CUMULATIVE POPULATION 90 2147 RING MILKS 0

2 5

10 RING POPULATION 992 2123 10429 TOTAL MILES 0

2 0

5 0

10 CUMULATIVE POPULATION 3115 13544 POPULATION TOTALS-~PEORIA POPULATION TOTALS RING MILES 0

2 2

5

$~10 RING POPV CATION 413 TOTAL MILKS 0

0 5

0 10 CUMULATIVE POPULATION 413 RING MILES 0

2 5

5 10 RING PO PV LA 1 I0 N 2213 12455

-TOTAL MILES 0

0 5

0 10 CUMULATIVE POPULATION 3205 15591 FIGURE 2 POPULATION NITHINTHE 10 MILE EMERGENCY PLANNING ZONE JULY 1954 REVISION 4

C C

I Q

C I

SI t'

5

\\

NW NNW N

Q Q122 NE WNW 30 548

~o Q126 35 ENE W 10 MILES 35 537 E

WSW 773 25 160

~25 Q

ESE SW

~< 8 6012 Q514 SE SSW 831 S

SSE KEY Industrial Employees Migratory Agricultural Workers Sportsmen 898 20 FIGURE 3 DISTRIBUTION OF TRANSIENT POPULATION WTHIN 10 MILES OF SITE 64OI60 2A ~

JULY 1964 QQAIQ24 ~

l C

v

0 c t loe5t SIREN COVERAGE x Cl+

~ ~

/

/

/'

Qw

'0 H' e+

0

]

P 4r C

560 0

)J.

~Ctpg+

=

~

T.

. thad' g,'

60 db 7P d l

yO 0

i./

OO' Jp p I@

'00 f'g W1 4o i

624 t<500 4

500 1

r tl I

I/

/

W'ceca 4oo

~ o Ct'-

(i900 t

r 7 5

g I

8 (p;

.. r>>

'p'~r

', ~

~

J.=-;,

r.

'I

. 0 I

+

~

~

400$

North le

~ e

+ou<o w~w y e7

~wY'lr ',

Cl I',

0~~

l lIIIIIat 0 mi.

wASNI'.tQtOi tl

%tlat'O'WC%

br'UPPLY SYSTEM 84-1075 FIGURE 4 SIREN/EMERGENCY BROADCAST SYSTEM COVERAGE CONTOURS

c

~

I 1'

FlGURE 5 EBS TONE ACTlVATEDRADlO

+o f

N II, 4,

'I l

l~

f

SlREN ASSEMBLY YAGlANTENNA SOLAR PANELS, 3 REQ'D

~~

~

0 0

POLE ASSEMBLY SEE DETAlL"F" DETAIL"F" 7.5 FEET APPROX. ///

~i ~/i

/

~>

10 FEET FIGURE 6 TYPICALSOLAR SIREN INSTALLATION A

t J'g~~

4 C'

i Q ger G

'LOiwbe F~w SC<s~'f S ~

I

+7 p iS+ Pgcru/5

,P

l P) l)

L

~

I