Text
I FLORIDA POWER & LIGHT COMPANY St. Lucie Plant Unit No. 1 License No. DPR-67 Docket No. 50-335 ANNUAL ENVIRONMENTAL RADIOLOGICAL MONITORING REPORT for The Period: 1-01-79 to 12-31-79 Prepared 3-21-80 8P P4P9 0819
p K4 g
- l. Introduction This report is sub@it~ in accordance with St. Lucie Plant Technical Specifications'ection 5.6.l.b.
7 All environmental samples were collected and analyzed during this report-ing pericd in accordance with require~ts of St. Lucie Plant's Technical Specifications. The minimum of frequency of collection and analyses for specific radionuclide species as required by these specifications have been met or exceeded except where samples were biologically unavailable No harmful effects or evidence of irreversible damage to the environment or to the health and safety of individuals or population groups in. the regions surrounding St. Lucie Plant have been detected by this monitoring program.
In addition to the Environmental Radiological Honitoring data, this report includes information about the semi-annual census for 500 ft2 gardens and milk-producing animals.
Strontium analyses for this reporting period have been'elayed due to the relocation of the State's Radiological Laboratory; these results will be sham in a separate report when analyses in progress are ccmpleted.-
- 2. The Mnitorin Program Anal 'cal Reszensibilitv Environmental radiological monitoring at St. Lucie Plant is car-ried out by the Orlando Radiological Laborator~ of the Department.
of Health and ~~abilitative Services of Florida (DHRS) personnel.
Nunber of Samples Anal ed A total of 1425 analyses were pe formed on1095szaples collected frcm 25 different san@ling locations during the period of this report. TABLE 1 sumnarizes the mean and range values of these analyses, Since 40K, 226Ra 232Th are naturally occurring radio-nuclides, no data for these species are recorded in this table.
The gross beta data reported is representative of these and other naturally occurring radionuclides.
Split S le Anal ses At least 20 of the sarrjles collected have be n analyzed in the DHRS/ERDA Split-Sample Program.
Evaluation of Data Except as noted in TABLE 1, none of the sampling locations used in the environmental radiological monitoring program showed evidence of having significant concentrations of a particular radionuclide in a specific sample material much nigher than the observed mean for that radionuclide at all s~~ . ling locations. Past, weapons testing fallout accumulations (as Sr, 95Zr, 131I, 137Cs and 4') observed at scme locations were not indicative of any effluent release by twit 1 during this operational period.
Trend plotting of our particulate and direct radiation data reveals no plant-related variations. Also, all data have been evaluated with re-spect to pre-operational data and hat== been found to'e witMn the + 2+
limits observed for these pre-operat'onal data. Carparative data obtam-ed in the assay of control samples also'ppears in TABLE l.
Da'erd, Goat, and Garden Census A dairv herd census was conducted in February and in August. during t~ais report period. The nearest dairy is west of the plant si o (260o; . 14 miles) Data obtained in the assays of samples collected at this location are reported in TABIZ l.
A':goat herd:census was conducted i'n February and in August during. this report period: The results. were; "no known goat herds in the County".
An aerial garden census in June, 1979 showed that there were several 500 ft2 g~e s with approx'y 5 miles of St. L cie Plant. T ass were sampled at Robert Canoan's, 7409 Indian River Drive: Results of these analyses appear in TABIZ 1.
- 5. Conclusions" During this period, the environmental radiological monitoring program has found no evidence that the operations of Plant St. Lucie Unit No. 1 contribute harmful effects or irreversible damage to either the environ-ment or to .the health and safety of individuals and population groups in the regions surrounding St. Lucie Plant.
~ ~ ~" o ~ ~ - ~ a"iaaf~~ ~a uter" ~rg~glr
~r ~
s4 ~auuat+aahkkasV"~dAJaoauLSana or Pathway Iiiimber :. Locations'ontrolta~
,All Indicator Loca ti on;wi th .llicheS t:.llean
~amp e ocatson Location Hurrher Nonroutine of ledium Analysis of'ites . Reported Sam led Unit for Sam les Anal ses titan Ran e Distance 5 Direction t"ean Ran e Mean Ran e lleasur'ements i0 AIR lo 1 AIR PARTIC-UIATFS pci/ta Cross 8 ~
9 463 463 02021 .045':30:,Residence,
,003 22 02 2,007-,019 0.006-7609 InIIian River .045 0.039 (b)
Drive 131 Air Iodincs pci/ta I 466 ND NA Camata Scan pci/m:3 108 108 NA s
89'0 pci/m 89s 36 35 ND NA (c) 90Sr ~ 36 35 ND NA anat~i, oi Filter Cota-posltea 1.2 Direct 19"23 5-6 Radiation II Rem/hr 9 36 36 6 . 3-23 H-12: (e) PoP.L. 21 5 (d) substation2 Stuart, Florida; '5.12 stiles 2.0 WATER 2.1.1 ~Di 1 r pCi/1 38 12 12 <200 NA Canal 89Sr 12 8 ND NA 90S 12 8 ND NA 2.1.2 ocean Ware pCi/1 II 24 24 <200 89S 24 16 ND 9'sr-2.1.3 Estaurine pci/1 ,
3II/ <200 NA Water 2.2 Ground PCi/1 H <200 .. Nh Iiater Well Cross 8-DS 4 ND NA Cross g-UDS 4 ND NA 2.3 Potable pci/1 H 3 12 12 <200 NA Water Cross 0-DS 3 12 12 ND-7 H-ll:St. Lucie County ND-7 NA NA Health Dept.,ptZRerc Gross 8-UDS 12 12 ND NA
~
e shetessDMAC4Ck'4'4344: 0$ Ct043CCL'C u3uttaSC 'OC.4CCvlsSC 4 vm SSXCJJ w VDM44'4-'144CsthCSC SACJLDs'v~hstsUL144ACIIA04SDS 0341sheseese All Indicator Location. with..nighest:.IIean Control~ Number of Number-of .. LocatMns Location
~
Nonroutine ss
'.odium or Pathway Analysis .sample ocat)on Reported Samnled Unit for Sites ~Sse les Aeslvses Hean Ran e Distance K Direction Hean Ran e Hean Ran e 'easurements 3.0 BOTTOM SEDIMENTS 3 1 ~Dischor'e pci%kg 54Mn 1 1 1 120A NA Canal" g7t 1 1 '1 110+ NA 1 2 1 ND NA
>>sr 1 2 1 ND NA 58Co 1 "2 2 200 110-290 ))-36: *+On site, Discharge Canal, West of AIA; ESE, 0.19 miles 60co 1180 260-2100 3.2 Ocean pci/kg 89sr 3 8 ND 'A
>>sr 3 8 ND NA 3.3 Beach Sane) pci/kg 89S 3 6 NA DOSE 3 6 NA 3.4 Eataurine (f) 4.0 hstshvte BIOTXA 4.1 Crustacca pci/kg Sr 2 40 (g) 90sr 2 4 89 4.2 . Fish pci/kg 2 4 3 ND NA Carnivore "sr 2 4 3 ND NA.
(h) 4.2.2 Fish pCi/kg 89sr 2 .3 ND NA Ner)livore 90sr ~
2 '3 ND NA (i)
- one sample tttSs One 1OCatiOn s
I s
4
TMlIZ 1 All Indicator Loca ti On.Mi th..fli oheS t..l jean Control( tlumber of
) Nonroutine Number of . L'ocetions Loca ti on~
odium or PathNay Analysis ~ample Vocation Reported Samoled Uni t for Sites ~Sam les Anal ses Mean Ran e Distance 5 Direction Mean Ran e Mean Ran e Measurements 5iO TERRESTRIAL BIOTA I
- 5. 1 Hil'k (k) pci/1 37 37 26.1 ND-40 I 11-40: (Control)Davis 28 1 18 40 26 1 ND-40 Dairy; Boynton Bcb.,
SSE, 55'.8 miles 89S 37 32 2-5 H-03: MeadoMbrook 2-5 2-3 90S Dairy; 14 ~iles, SSM.
1 37 32 ,ND NA 1311 37 36 <.62 <.5-<2 '-03: Meadovbrook <.64 <.5-<2 <.58 <.5-<1 Dairy; 14 miles, SSM.
5.2.1 Foo<l - (1) pCi/kg 89Sr 7 7 7 ND NA Citrus 90Sr 7 7 7 21 .
7-45 11-22: Lentr. Groves, 45* NA U.S.l:, SSM, 5.5 mil 5.2.2 Food (m) pci/kg 137Cs" 100'A ~ N-41: Robert Carman's 100" NA
~l.eaf 7409 Indian River
~Ve etables Drive; WSMy 2 miles 131 5.3 SOIL (n)
- one sample
TABLE 1 NOZi&
= Non Applicable ND = None Detectable
.) Control Location, H-32: Department of Health and Rehabilitative Services, Entcmology Laboratory, East of U.S. 1, Ve o Beach, hVil, 19 miles b) 1.1 Air Particulate, H-09, H-10, & H-14: were each found on one occasion to be without a particulate filter during sample collection for this reporting pericd H-14: on Oct. 10, 1979, low sample volume due to e~~ ~ '@vent failure H-30: On one occasion sample was not collected due to operator error c) Anal ses of Filter sites, Sr 6 Sr , H-09: one analysis was lost due to insufficient chemical yield in laboratory prccessing. All other results were Non-Detectable.
d) 1.2 Direct Radiation: data reflects net dosimeter response average of two (2) dosimeters for each sampling location H-10: On Oct. 10, 1979, results from one (1) T.L.D. were lost due to operator error e) H-12: this rrnnitor is located on/near natural radioactivity contained
.in fill..material. All other monitors had' mean of 5 pRem/lm and a range of 3 to 6 +Bern/hr
3.4 Estaurine
4 K, 6Ra, a 232Th were the only radionuclides found in these san@les
4.1 Cr'usiacea
blue crab, shrimp h) 4.2.1 Pish-Carnivore: mized, large mouth bass i) 4.2.2 Fish-Herbivore: mullet Control Location H-40: Davis Dairy, Boynton Beach, SSE, 55.8 miles k) 5.1 Milk H-03, H-40: on 8-8-79 and 12-27-79 respectively, 89 Sr & 90 Sr results were lost due to spoilage of s~vples H-03: routine split;sarple for I131 analysis, to Eberline Corp. on 2-2-79, w s destroyed in shi~t by the U.S. Postal Service. Results of the make-up sample collected on 2-16-79, are included in all data for 5.1 K.lk
- 1) 5.2.1 Food-Cites: grapefruit, citrus, oranges m) 5.2.2 Food-Leaf V etables, H-41: tomatoes; Robert Canaan's, 7409 Indian River Drive n) 5.3 Soil: san@les once per three (3) year period the last sampling pericd was in 1977
FLORIDA POWER G LIGHT COHPANY St. Lucie Plant Unit No. 1 License No. DPR-67 Docket No. 50-335 ANNUAL ENVIRONMENTAL RADIOLOGICAI MONITORING REPORT for The Period: 1-01-79 to 12-31-79 Prepared 3-. 21-80
Introduction This report is sutmitted in accordance with St. Lucie Plant Technical Specifications'ection 5.6.1.b.
AU. environmen~ samples secre collected and analyzed during this report-ing period in accordance with require~i.its of St. Lucie Plant's Technical Specifications Th minima of fr~ency of collection and analyses for specific radionucli¹ species as required by these specifications have been met or excee2aR except where sa~les were biologically unavailable.
No harmful effects or evidence of irreversible damage to the enviroment or to the health and safety of individuals or population groups in tlute regions surrounding St. Lucie Plant have been detected by this monitoring pxogram.
Xn addition to the Environmental Radiological lanitoring data, this report includes information about the seni-annual census for 500 ft2 gardens and milk-producing animals.
Strontium analyses for this reporting p riod nave been delayed due to the relocation of the State's Radiological Laboratory; these results ~rill be st~ in a separate report when analyses in progress are completed.
- 2. The banitorin Pr ram, Anal meal R nsibilit Environmental radiological monitoring at St. Lucie Plant is car-ri~ out, by the Orlando Radiological Laboratory o" the Department of Health and H&abilitative Services of Florid= (DHRS) personnel.
N'~i of S les Anal zed A total of 1425 analyses were pe"form d on1095smples collected frcm 25 different sampling loca"'cns duing the p riod of this report. TABLE 1 sumnarizes the m an and range values of these analyses. Since 40K, 226Ra, 2~ <h are na urally occurring radio-nuclid s, no data for these sa 'ies ar recorded in this table.
Th gross beta data reported is represent..tive of tliese and other naturally occurring radionuclid s.
Split Sample Anal ses At least 20 of the .samples collected have been analyzed in the DHRS/ERD~ Split-Sample Program.
Evaluation of Data E-cept as noted in TABLE 1, none of the sampling locations used in the environmental radiological monitoring program showed evidence of having significant concentrations of a particular radionuclide in a specific sample material much higher than the observed m an for that radionuclide at all sampling locations. Past weapons testing fallout acmaulations
- {as 9 Sr, 95Zr, 1311, 137Cs and "i~5) observed at scme locations xzre not indicative of any effluent release by M.t 1 during this operational p riod.
Trend plotting of our particulate and direct radiation data reveals no plant-related variations. Also, all data have been evaluated with re-spect to pre-operational data and have been found to be wit!6n the + 2+
limits obsexved for these pre-operational data. Ccaparative data obtain-ed in the assay of control samples also appears in TABES 1
- 4. Da'erd, Goat, and Camden Census A daixy herd census was conducted in Pebruaxy and in Auger during tMs report p riod.. The nearest dairy is west of the plant site (260o; . 14 miles) Data obtained in the assays of samples collected at this location are reported in ALE l.
A goat herd census ~ras conducted-in February and in August during. this report period.': The 'results.'<ere "no Grown goat~ds in the County".
An aerial garden census in June, 1979 shol~e9. that there vivre several 500 ft2 gardens within approv~tely 5 miles of St. Lucie Plant. Tcmatces were sampled at Robert Caxman's, 7409 Indian Riv r Drive; Results of these analyses appear in TABLE 1.
- 5. Conclusions During this period, the environmental radiolcgical monitoring program has found no evidence that th operations of Plant St. Lucie Wit Ão. 1 contribute haxmful effects or irreversible damage to either the or to the health and safety of individuals and population groups environ-'ent in the regions surrounding St. Lucie Plant.
All rndicator Loca ti on;>)i th .fiiehes t:J'iean Control~a~ Number of hdium or Pathrfay Analysis
'umber
~ AWL4lk~or" i . 'I'.Ooatvons'ean
.amplWeocati on Location Honroutine Reported Sampled Unit TOl Sites Samples Anal ses Ran e Distance 6 Direction Mean Ran e Mean Ran e rveasure...ents 1.0 AIR 1.1 AIR PARTIC-U1ATEs pci/rrr Gross 5 9 463 463 0. 021 0.003 H:30l.Rcoidcncc, , 02 2,007-..019 0.006-(b) 0.045 7609 Indian River .045 0.039 Drive 131 1.1 Air Iodines pci/sr 466 466 ND NA
-3 1.1 Canna Scan pci/rrr 108 108 Sr S
09'0 pci/m 89S 9 36 35, ND NA (c) 90sr 9 36 35 trD NA hnnlv!r le of Filter Cora-1.2 Direct Radiation rr Rcrrr/hr 36 36 6 ~ - 3-23 H-12: (e) P,P+Lo 21 19<<23 5 5-6 (d) substation, Stuart, Illorida; 5,12"raileo 2.0 WATER 2.1.1 Disch~aroe pci/1 3H 1 12 ~ 12 <200 NA Canal 89sg 1 12 8 ND NA 90sr 1 12 8 ND NA 2.1.2 Ocenn Wntc pci/1 ll 2 24 24 <200 Nh 8 Sr 2 24 '16 ND NA
'0Sr.
2.1.3 Estnurine pci/1 <200 NA Water 2.2 Ground pci/1 H 1 4 <200 . Nh Water 'h'cll Gross il-DS 1 4 ND NA Gross 8-UDS 1 4 ND Nh 2.3 Potnblc pCi/1 Il 3 12 12 <200 NA Water Gross 0-DS 3 12 12 4 ND-7 H-ll:St. Lucio County SD-7 5 N,rr. ~ NA Health DcPt rptZkcrc Gross ir-UDS 12 12 . ND NA
All indicator Locati on.w> th..tt>9hest..i ean Control~ 'hur..her of
~
Honroutine nimbi. r -of Locations Location
'.ediun or Pathway Analysis 'i Sanple ocat>on Reported Saraoled Unit for tes Sam les Analvses )lean Ranee Distance h Direction l~iean Ran e ldean Rance Y, asurea:ents 3.0 BOTTOV SBDPKNTS 3.1 ~D1 char r pCi'/kg 54Nn 1 1 1 120A NA Canal- )5Z:. 1 1 '1 llO+ NA 9sr 1 2 1 hD NA 90Sr 1 .. 2 1 ND hA 58co 1 2 2 200 110-290 11-36: <<Aon site, Discharge Canal, Vest of AIA; ESE, 0.19 mlles Goco 1100 260-2100
'C 3.2 Ocean pCi/kg 09sr 3 8 4 ND NA
>>s>> . 3 8 4' ND NA i 3.3 Beach Sand pci/kg 09 3 6 NA
'OSr 3 6 4 NA 3.4 Estaurinc 4.0 ~hUhTZC BIOTlA 4.1 Crustacca pCi/kg "sr 2 4 ND NA (0) 90Sr 2 4 ND NA 09 4~2 . Fish pci/kg Sr 2 4 ND NA Ca rnivorc 90S 2 4 ND NA.
(h) 4,2.2 Fish pci/kg "sr 2 .3
'3 ND NA Ncrbivorc 9'sr ~
2 ND NA (i) onc sample sa one location
C~Ld TSSI'JGVJRaaSSJr~~'~&~dS~~JJSS Ssa'aPWAMC, rTCSWSQCVJZJS:S CL'll-ITn1 same easemal J'le>> lasTSTJ JIc1 sssv Is@'ass TQA wQTRsraaaJTRR ae'mseeaamameemesaaea
,ma e ~
- ~
TABLC 1 All Indicator Location.<'(< th..lllgheS t..llean Control( Number of Location
~
Honroutine "tliTmber. Locations"
'odium or Pathuay Analysis of's
- Ramp'le Vocat on Reported Sari led Unit for tea ~Sam Tes Analvses Mean Ra~n e Oistance f Direction Wean Ran e Yaean ~Ran e Heasurements 5e 0 TERRESTRIAL BIOTA 5.1 Hilk (k) pCi/1 137C 37 37 26.1 ND-40 H-40: (Control)Davis 28el 18 40, 26el sSD-40 Dairy; Boynton Bchee SSE, 55.8 miles .
89Sr 3? . 32 2-5 H"03: NcadoMbrook 2-5 2-3 Dairy'; 14 miles, SSW.
"Sr 37 32 .ND NA 131I 37 36 <.62 <.5-<2 '-03: NcadoMbrook <.64 <.5-<2 <.58 <.5-<1 Dairy; 14 milcse SSW.
5.2.1 - 89Sr Pood Citrus (1) pci/k8 90sr '7
. 7 7 7
7 7
ND 21 NA 7-45 H-22l Lent'. Groves, 45s NA U S lie SSWR 5 ' 'mil 5.2.2 Food - (n) pCi/kg 137cs 100> NA . H-41: Robert Carman s 100* NA
~Leaf 7409 .Indian River
~sea alee Drive; WSW, 2 miles 131 NA
- 5. 3 SOIL (n)
- one sample
NA = Non Applicable ND = None Detectable a) Control Location, H-32: Department of Health and Rehabilitati:ve Services, Entomology Laboratory, East of U.S. 1, 'v'ero Beach, Kii;1, 19 miles
~ ~
/
b) 1.1 Air Particulate, H-09, H-10, & H-14: were each found on one occasion to be without a particulate filter during sar~pie collectionfor ..
this reporting period H-14: on Oct. 10, 1979, low sample volun du to equi~~t failure H-30: On one occasion sample was not collec~ due to operator error c) Analyses of Filter sites, Sr & Sr , H-09: one analysis was lost due to insufficient chemical yield in laboratory processing. All other result were Non-D tectable.-
d)
(2) Qosirraters for each sampling location t
1.2 Direct Radiation: data reflects n dosim ter response average of two H-10: On Oct. 10, 1979, results frcm one (1) T.L.D. were lost due to operator error e) H-12: this monitor is located on/near natural radioactivity contained
,in fill.material.'ll other monitors had a mean of 5 pRezn/hr and a range of 3 to 6 +Bed~
3 4 Estaurine. 40K '26Ra & 232Th were the only radionuclides found in these
~@les
.) 4.1 Crustacea: blue crab, shrinp h) 4.2.1 Fish-Carnivore: mixe, large rmuth bass 4.2.2:ish-H ~bivore: mullet.
Control Location H-40: Davis Dairy, Poynton Beach, SSE, 55.8 miles 5.1 Milk H-03, H-40: on 8-8-79 and 12-27-79 restively, 89 Sr .
90 Sr results were lost due to spoilage of sa~) les H-03: routine split-sarple for E131 analysis, to Eberline Corp. on 2-2-79, was destroyed in shipment by De U.S.. Postal Service. Results of the M~ e-up sa~le collected on 2-16-79, are included in all data for 5.1 Milk
5.2.1 Food-Cites
grapefruit, citrus, orang s 5.2.2 Food-Leaf V etables, H-41: tomatoes; Robert Carman's, 7409 Xndian Mv Drive n) 5.3 Soil: samples once per three (3) year p riod the last 'sampling pericd was in 1977
-P
~~
l l,
1 A
t