ML17223B004

From kanterella
Jump to navigation Jump to search
NPDES Discharge Monitoring Rept for Sept 1990. W/901114 Ltr
ML17223B004
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 09/30/1990
From: Sager D
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
L-90-398, NUDOCS 9011200287
Download: ML17223B004 (7)


Text

ACCESSION NBR:9011200287 t

REGULATORY INFORMATION DISTRIBUTION DOC.DATE: 90/09/30 STEM NOTARIZED: NO (RIDS)

DOCKET FACIL:50-535 St. Lucie Plant, Unit 1, Florida Power 6 Light Co. 05000335 AUTH. NAME AUTHOR AFFILIATION

'SAGER,D.A. Florida Power & Light Co.

RECIP.NAME RECIPIENT AFFILIATION

SUBJECT:

"NPDES Discharge Monitoring Rept for Sept 1990." W/901114 ltr.

DISTRIBUTION CODE: IE23D COPIES RECEIVED:LTR 2 TITLE: Environmental Event Report (per Tech Specs)

ENCL I SIZE:

NOTES:

RECIPIENT COPIES RECIPIENT COPIES ID CODE/NAME LTTR ENCL ID CODE/NAME LTTR ENCL PD2-2 LA 3 3 PD2-2 PD 1 1 NORRISgJ 1 1 INTERNAL: ACRS 5 5 AEOD/DSP/TPAB 1 1 AEOD/PTB 1 1 NRR/DREP/PEPB9D 1 1 NRR PMAS~RB12 1 1 OGC/HDS2 1 1 G FIL~

~CN~DRS S/EPRPB Ol 1 1

1 1

RGN2 1 1 EXTERNAL: NRC PDR 1 1 NSIC 1 1 TOTAL NUMBER OF COPIES REQUIRED: LTTR 20 ENCL 20

h P

II I

f

'\

II

P.O. Box 14000, Juno Beach, FL 33408-0420 NOV 1 4 l996 L-9 0-3 9 8 U~ S ~ Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Gentlemen:

Re: St. Lucie Unit 1 Docket 5 0-3 3 5 Environmental Protection Plan Report National Pollutant Dischar e Elimination S stem NPDES Re ortable Event In accordance with Section 3 2 1 of the St. Lucie Unit 1

~ ~

Environmental Protection Plan, attached is a copy of the Report (DMR) required by the St. Lucie Plant NPDES Discharge'onitoring Permit with respect to a reportable event. Additionally, a description of the event. is provided.

Very truly yours, sgS -~

Vice President St. Lucie Plant DAS: J JB: kw cc: Stewart D. Ebneter, Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, St. Lucie Plant

/

DAS/PSL N 282 I'0 i i 200237 PDR ADOCK R

l 0 5000335 an FPL Group company

'LC P

j4 g ~

ATTACHMENT DESCRIPTION OF THE EVENT Flow readings for the Unit I sewage treatment plant were not recorded between 9/15/90 and 9/30/90. These readings are required weekly by EPA.

The plant was inspected at least once daily during this time frame and no abnormal flows were observed. The flow meter indicated flow properly, but the chart recorder did not advance, and the totalizer did not register the flow.

The problem was corrected on 10/I/90. It was discovered that the flow meter had two separate power supplies. One breaker powered the flow indicator, and a breaker labeled "Aux. Receptacle" breaker had been placed in the OFF position. This breaker has been relabeled "Effl. Flow tteter." It is not expected this situation will recur.

PERMITTEE NAMEIADDRESS(lndudc NATIONALPOLLUTANTDISCHARGE ELIMINATIONSYSTEM (NPDESJ DISCHARGE MONITORING REPORT(DMR)

NAME IFL ('cfiP. f LT ST LUCIE (2-)6J (I7-I9) F FINAL ADDRESs f'NVIRONMENTAL AFFAIRS FL0002208 00(t 1 SEHAGE TRTMNT PLANT PO BOX l4000 PERMITNUMBER DISCHARGE NUMBER JUNO BEACH FL 33(tos 1 i MONITORING PERIOD FACILITY YEA 0 D Y Y D Y LOCATION FROM TO MAJOR (SUBR JA)

ATTN: T~ Re F AIR (20 2I) (22-23) (2d.25) (26 27) (28-29) (30.3IJ NOTF Read instructions before completing this fdrm.

(3 Curd OnlyJ QUANTITYOR LOADING (d Cant Oct(7) QUALITYOR CONCENTRATION NO. FREQUENCY SAMPLE PARAMETER (d&53J (5dAI) (3845 J (46453) (5AU) EX. ,OF TYPE (32-37) ANA'LYSIS AVERAGE MAXIMUM , UNITS MINIMUM AVERAGE MAXIMUM !UNITS (6W9 (6468J (69.70)

BODv 5-DAY

&r vv 4r rrhrv he4 vvh r r I ehhh heh ~

eh eh V rh rh re VVV re SAMPLE (20 DFG C) MEASUREMENT rr r 00310 G DEGAS 0 0 PERMIT r eh I r r h4 hr ~ree4 rhrhr ~ rhr rr r e4 r eh R POR R RAH SEH/INFLUENT "LREQUIREMENT ht e 1 I 'I r'hhr r4 r KIAX.Q'V DAZLYiieM . MG/L

'ROD 5-DA Y v 4 hrhev r v ehv eh V ettrhhV'V rer ooelel r r hrVV

{20 C)

SAMPLE MEASUREMENT r hrwr hr wr rr hhQ 0

00310 1 0 0 PERMIT rv v'hrhrhr e

r VVIV ll rh hrhhhrV g TgLYw JAB I= F FLUFNT GROSS VALU IREOU)liEMENTg W r rhrr hhhh ~.'0'I)AIL',Y AV 60AILY'.Mg MG/Lt rrrr rA SAMPLE MEASUREMENT eheh rV hrrVV Jl eh e

rrr I

v' hr v hr hr 0 M~

00(t00 1 0 0 rer ehr rV'V V'heV hrrr rV444' eetr r 'll "6e 0 IC r v hr hr 'v 9a0$ EEKL, t AB PERMIT v't it V'AII wl r rhr V 'INIMUM~

h EFFLUEAT GROSS VALUf !REQUIREMENT t, ~ e4 e4 Ct MAXIMUMP. SU r44rrr

~

SOL I i)S 9 TOTAL SAMPLE rerr44 V V e'VV

~

4 4 4ree4A VlrerV rV' h erh Ver V MEASUREMENT SUSPENDED 00530 G 0 0 PERMIT

&r rVV' ll ehr hr., r 4 hr r r 4h4 hh le"hl hrer 4ehA'

~RAPPORT 'tRgPO(T ~<

g . At we TRLY@ iIAB 4r

'I IWl JEOUIRELIENTg~'

BAH SFH/INFLUENT hr 'll r +i AV :.'.DAILY OAZLYl MX MG L SOLIDS'OTAL SAMPLE r )r rrhh4 ~ h lr ht ht V hr V ehr r e4 heh

'lr MEASUREMENT SUSPLNDED 00530 l 0 0 PERMIT

REQUIREMENT Ct VV V rhhV r- rr'ht 4 vs',hrv'he rhvv e4r 4r r eh)4el

~ e IW.

r he V'r lee

-:e30 60" j 'j'gL @ RAB F'FFLUFNT GROSS VALUI AV 'CDAlL'Y O'ASLYC M MG L 5 Cc t2'CC FLOHB IN CONDUIT OR 4 4 4ehrtrhe4 AA v r hrsr rhrvh4 4rr hr v' vehrr'v v SAMPLE MEASUREMENT THRU TRFATMENT PLAN 50050 1 0 0 PERMIT.

REQUIREMENT,

" ".0 ~ 017" 'EP.ORT =; 'tv hr EEKLI..

EFFLUFNT GROSS VALUI z)A'ILY -"AV; :DA"IL'-Y"CMX: MGD Qt I

COL FORM 9 FFCAL SAMPLE r eh hr r

~ rrvv rehhhhrvv 4 4 v rrvhhv GENERAL MEASUREMENT Atr A,r r vrer A rw4&r re Ar vhr ehr A t/ TRLY RAB 7(t05 5 1 0 0 PERMIT r ~

~

erhf hhhr ~ r hr hl ~ V4 V'r rhrvhr REPORT -; ~ Ael FF F. T G lSS lll REQUIREMENTS 1 4I th 1 4 teh ss ~ it~ 0 YI MX 100ML e paltr ot lee that tale ooeaat all sttaotaesto TELEPHONE DATE NAME/TITLEPRINCIPAL EXECUTIVE OFFICER I settler easer ooo sore enpno aaor ec olroetla ec eoeotslsloa la eotctooee elth

~ etsta eatpoo te osan ost esstlcloo proeaat peptic tsost aat eralssto the lscoraetlea eohatttoc. Boost ee ec taostrc ec

'stop Or proeSO eae Sheep OO Ctatae Or Ooee proces ~ lnsttt raspathte tet eaOertat OO Iaterattae the tatetatta

~

Oehatttett lo te the hat Ot et hoateate Sat artiste tnee aseratee ae SIGNA RE OF P IPAL EXECUTIVE eoeetote '1 a caco Ost ttece aN slteltloost tatectae Oo tooolhllttt oC Clos aaa patttoe foc

'FFICER OR AUTHORIZEDAGENT A NUMBER YEAR Mo DAY TYPED OR PRINTED ~ ohsttttae tales tstonattae ototottoa tsertsoaat Cer 4k~

hoosier COMlttENT AND EXPLANATIONOF ANYVIOLATIONt ALL iIONITORING OiNCE PER BATCH ~ EFFLUENT SHALL BE AEROBIC AT ALL TIMES ~ ~ ~tte~

EPA Form 3320-1 (Rev. MS) Previous editions In ay be used. IREPLACES EPA FORM TM WHICH MAYNOT BE USED'1153/900709-2027 PAGE 1

OF

t