Appendix H3 -

RESRAD-Offsite 3.11 nput Param differ from defaults-Area 1

Attachment H3: RESRAD-Offsite 3.1 Inputs Parameters for Area 1 that differ from defaults Parar\\;\\et~r RESRAD-Offsite Default Area.L12 Area L23

  • Basis Preliminary Inputs Exposure Duration 30 1

1 Yearly dose estimates calculated.

Site Layout X dimension of Primary 100 Contamination 240 467 Y dimension of Primary 100 290 280 Contamination Non-Leafy Plot X: 34.375 I 65.625 X: 0/ 1 X: 0I1 (Smaller/ Larger)

Y: 234 I 266 Y: 0I1 Y: 0I1 Leafy Plot X: 34.375 I 65.625 X: 0I1 X: 0I1 (Smaller I Larger)

Y: 234 I 266 Y: 0I1 Y: 0I1 Pasture X: 0I100 X: -425 I 810 X: 0 I 715 Google Maps used to estimate (Smaller I Larger)

  • Y: 450 I 550 Y: -0 I 860 Y:-685 I 715 distances using satellite images.

Grain X: 0 I 100 X: 0I1 X: 0 I 1 (Smaller I Larger)

Y: 300 I 400 Y: 0I1 Y: 0I1 Dwelling X: 34.375 I 65.625 X: 80I187 X: 0 I 120 (Smaller I Larger)

Y: 134/ 166 Y: 0I107 Y: 95I190 Surface-water Body X: -100 I 200 X: -425 I 810 X: 311 I 467 (Smaller I Larger)

Y: 550 I 850 Y: 860 I 910 Y: -175/-58 Distribution Coefficients Ac-227 20 n/a n/a Am-241 20 n/a n/a Sediment: 480 Sediment: 480 Cs-137 4600 All others: 280 All others: 280 Np-237 257 n/a n/a Pa-231 50 n/a n/a Phase 1 Decommissioning Plan for Pu-239 2000 n/a n/a the West Valley Demonstration Project Rev_ 2 Attachment C.

Sediment: 15

  • Sr-90 30 n/a Al I others: 5 Th-229 60000 n/a n/a U-233 50 n/a n/a U-235 50 n/a n/a Pathways No consumption of fish based on External, Inhalation, Plant land use surveys. Meat Ingestion, Meat Ingestion, External, Inhalation, External, Inhalation, consumption for Area 1 is assumed Include Milk Ingestion, Aquatic Meat Ingestion, Drinking Meat Ingestion, Drinking to be deer meat. No livestock to Foods, Drinking Water, Water, Soil Ingestion Water, Soil Ingestion produce milk is available for Area Soil Ingestion
1.

Physical and Hydrological Phase 1 Decommissioning Plan for Precipitation 1

1.16 1.16 the Wes~ Valley Demonstration Project Rev 2 Attachment C.

Page 1of6

Attachment H3: RESRAD-Offsite 3.1 Inputs Parameters for Area 1 that differ from defaults

  • pa*rameter.: **

RESRAD,Offsite Defau'it

  • ,A:r:ea L12*

Area Li3*

<Basis Phase 1 Decommissioning Plan for the West Valley Demonstration Wind Speed 0.89 (calculated)

Wind Rose Wind Rose Project Rev 2 Table 3-10: Wind Speed and Direction Frequency Distributions at 10 Meters.

Primary Contamination Phase 1 Decommissioning Plan for the West Valley Demonstration Project Rev 2 Attachment C; Length of contamination 100 165 165 Selected to achieve site specific parallel to aquifer flow groundwater dilution factor of 0.2, based on DEIS groundwater model correlation.

Irrigation 0.2 0

0 No crops produced.

Based on the Phase 1 Decommissioning Plan for the West Valley Demonstration Project Evapotranspiration coefficient 0.5 0.62 0.62 Rev 2 Attachment C; Evapotranspiration and runoff coefficients selected to achieve infiltration rate of 0.26 m/y.

Phase 1 Decommissioning Plan for the West Valley Demonstration Runoff 0.2 0.41 0.41 Project Rev 2 Attachment C; Evapotranspiration and runoff coefficients selected to achieve infiltration rate of0.25 m/y.

Phase 1 Decommissioning Plan for Thickness 2

1 1

the West Valley Demonstration Project Rev 2 Attachment c.

Phase 1 Decommissioning Plan for Total Porosity 0.5 0.36 0.36 the West Valley Demonstration Project Rev 2 Attachment C.

Phase 1 Decommissioning Plan for Dry bulk density 1.5 1.7 1.7 the West Valley Demonstration Project Rev 2 Attachment C.

Phase 1 Decommissioning Plan for the West Valley Demonstration Project Rev 2 Attachment C. Set to 0.5 for Area 2 to maximize surface Soil erodibility factor 0.4 0.5 0.5 water pathway associated with deer drinking water. Set to zero for Area 3 to ensure no source depletion as there are no pathways for exposure associated with surface water.

Phase 1 Decommissioning Plan for Field Capacity 0.3 0.2 0.2 the West Valley Demonstration Project Rev 2 Attachment C.

Phase 1 Decommissioning Plan for B parameter 5.3 1.4 1.4 the West Valley Demonstration Project Rev 2 Attachment C.

Phase 1 Decommissioning Plan for Hydraulic conductivity 10 140 140 the West Valley Demonstration Project Rev 2 Attachment C.

Page 2 of 6

Attachment H3: RESRAD-Offsite 3.1 Inputs Parameters for Area 1 that differ from defaults

.. Parameter RESRAD,Qffsite Default

  • Areau2 Area L2_3..

Basis Phase 1 Decommissioning Plan for Effective Porosity 0.4 0.25 0.25 the West Valley Demonstration Project Rev 2 Attachment C.

Agricultural Areas Non-leafy: 0.2 Non-Leafy: o Non-leafy: O Leafy: 0.2 Leafy: O leafy: 0 Phase 1 Decommissioning Plan for Irrigation Pasture: 0.2 Pasture: O Pasture: 0 the West Valley Demonstration Grain: 0.2 Grain: O Grain: o*

Project Rev 2 Attachment C.

Dwelling: 0.2 Dwelling: O Dwelling: 0 Non-leafy: 0.5 Non-leafy: 0.62 Non-leafy: 0.62 Leafy: 0.5 Leafy: 0.62 leafy: 0.62 Phase 1 Decommissioning Plan for the West Valley Demonstration Evapotranspiration coefficient Pasture: 0.5 Pasture: 0.62 Pasture: 0.62 Project Rev 2 Attachment C.

Evapotranspiration and runoff Grain: 0.5 Grain: 0.62 Grain: 0.62 coefficients selected to achieve infiltration rate of0.26 m/y.

Dwelling: 0.5 Dwelling: 0.62 Dwelling: 0.62 Non-leafy: 0.2 Non-Leafy: 0.41 Non-leafy: 0.41 leafy: 0.2 leafy: 0.41 Leafy: 0.41 Phase 1 Decommissioning Plan for the West Valley Demonstration Runoff Pasture: 0.2 Pasture: 0.41 Pasture: 0.41 Project Rev 2 Attachment C.

Evapotranspiration and runoff Grain: 0.2 Grain: 0.41 Grain: 0.41 coefficients selected to achieve infiltration rate of0.26 m/y.

Dwelling: 0.2 Dwelling: 0.41 Dwelling: 0.41 Non-Leafy: 1.5 Non-leafy: 1.7 Non-Leafy: 1.7 leafy: 1.5 Leafy: 1.7 leafy: 1.7 Phase 1 Decommissioning Plan for Dry bulk density Pasture: 1.5 Pasture: 1.7 Pasture: 1.7 the West Valley Demonstration Grain: 1.5 Grain: 1.7 Grain: 1.7 Project Rev 2 Attachment C.

Dwelling: 1.5 Dwelling: 1.7 Dwelling: 1.7 Non-leafy: 0.4 Non-leafy: O Non-Leafy: O leafy: 0.4 leafy: O Leafy: O Phase 1 Decommissioning Plan for Soil erodibility factor Pasture: 0.4 Pasture: 0.5 Pasture: 0.5 the West Valley Demonstration Grain: 0.4 Grain: O Grain: O Project Rev 2 Attachment C.

Dwelling: 0 Dwelling: 0 Dwelling: O Atmospheric Transport.

Phase 1 Decommissioning Plan for Joint Metrological Data (Wind the West Valley Demonstration Speed/ Stability class n/a Wind Rose Wind Rose Project Rev 2 Table 3-10: Wind frequency)

Speed and Direction Frequency Distributions at 10 Meters Unsaturated Zone Hydrology Phase 1 Decommissioning Plan for Thickness 4

2 2

the West Valley Demonstration Project Rev 2 Attachment C.

Phase 1 Decommissioning Plan for Dry bulk density 1.5 1.7 1.7 the West Valley Demonstration Project Rev 2 Attachment C.

Phase 1 Decommissioning Plan for Total Porosity 0.4 0.36 0.36 the West Valley Demonstration Project Rev 2 Attachment C.

Phase 1 Decommissioning Plan for Effective Porosity 0.2 0.25 0.25 the West Valley Demonstration Project Rev 2 Attachment C.

Phase 1 Decommissioning Plan for Field Capacity 0.3 0.2 0.2 the West Valley Demonstration Project Rev 2 Attachment C.

Page3of6

Attachment H3: RESRAD-Offsite 3.1 Inputs Parameters for Area 1 that differ from defaults Parameter RESRAD-Offsite Defau It Area L12 Area L23 Basis Phase 1 Decommissioning Plan for Hydraulic conductivity 10 140 140 the West Valley Demonstration Project Rev 2 Attachment C.

Phase 1 Decommissioning Plan for B parameter 5.3 1.4 1.4 the West Valley Demonstration Project Rev 2 Attachment C.

Saturated Zone Hydrology Phase 1 Decommissioning Plan for Dry bulk density 1.5 1.7 1.7 the West Valley Demonstration Project Rev 2 Attachment C.

Phase 1 Decommissioning Plan for Total Porosity 0.4 0.36 0.36 the West Valley Demonstration Project Rev 2 Attachment C.

Phase 1 Decommissioning Plan for Effective Porosity 0.2 0.25 0.25 the West Valley D.emonstration Project Rev 2 Attachment C.

Phase 1 D~commissioning Plan for Hydraulic conductivity 100 1400 1400 the West Valley Demonstration Project Rev 2 Attachment C.

Phase 1 Decommissioning Plan for Hydraulic Gradient 0.02 0.03 0.03 the West Valley Demonstration Project Rev 2 Attachment C.

Phase 1 Decommissioning Plan for Depth of aquifer contributing 10 5

5 the West Valley Demonstration Project Rev 2 Attachment C.

Water Usage Phase 1 Decommissio.ning Plan for Consumption 510 730 730 the West Valley Demonstration Project Rev 2 Attachment C.

Phase 1 Decommissioning Plan for Number of Humans 4

4 4

the West Valley Demonstration Project Rev 2 Attachment C.

Phase 1 Decommissioning Plan for Dwelling 225 225 225 the West Valley Demonstration Project Rev 2 Attachment C.

Phase 1 Decommissioning Plan for Beef Cattle 50 50 50 the West Valley Demonstration Project Rev 2 Attachment C.

Area 1 beef cattle represent deer; Number of Beef Cattle 2

5 5

Phase 1 Decommissioning Plan for the West Valley Demonstration Project Rev 2 Attachment C.

Surface/Well 0/1 Jan-00 Jan-00 Assumed deer drink from surface water locations.

Dairy Cattle 160 0

0 No dairy cattle in Area 1.

No dairy cattle in Area 2; Phase 1 Number of Dairy Cattle 2

0 0

Decommissioning Plan for the West Valley Demonstration Project Rev 2 Attachment C.

Irrigation Non-Leafy 0.2 0

0 No crop field.

Irrigation Leafy 0.2 0

0 No crop field.

Irrigation Pasture 0.2 0

0 No irrigation of pasture area.

Irrigation Grain 0.2 0

0 No crop field.

Irrigation Dwelling 0.2 0

0 No irrigation of dwelling.

Well Pump Rate 5100 1394 1394 1394 m 3/y=730 L/d x 4 humans+

225 L/d x 4 humans Surface Water Body Page 4 of 6

Attachment H3: RESRAD-Offsite 3.1 Inputs Parameters for Area 1 that differ from defaults Param.eter RESRAD-Offsite Default Area L12.

Area L23; ~

Basis Based on Surface-water Body Volume 150000 61750 17940 layout and an average water depth of 1 meter.

Ingestion Rates Phase 1 Decommissioning Plan for Drinking Water Consumption 510/1 730/1 730/1 the West Valley Demonstration Rate/Fraction Affected Project Rev 2 Attachment C.

Fish Consumption 5.4/0.9 0/1 0/1 No consumption offish based on Rate/Fraction Affected land use surveys.

Phase 1 Decommissioning Plan for Crustacea Consumption 0.9/0.5 0/1 0/1 the West Valley Demonstration Rate/Fraction Affected Project Rev 2 Attachment C.

Non-Leafy Consumption 160/0.5 0/1 0/1 No non-leafy vegetation grown.

Rate/Fraction Affected Leafy Consumption 14/0.5 0/1 0/1 No leafy vegetation grown.

Rate/Fraction Affected Phase 1 Decommissioning Plan for the West Valley Demonstration Meat Consumption 63/1 65/1 65/1 Project Rev 2 Attachment C. For Rate/Fraction Affected Area 1, meat consumption represents deer meat.

Phase 1 Decommissioning Plan for Milk Consumption 92/1 0/1 0/1 the West Valley Demonstration Rate/Fraction Affected Project Rev 2 Attachment C. There are no dairy cattle in Area 1.

Phase 1 Decommissioning Plan for Soil Consumption Rate 36.5

  • 18.3 18.3 the West Valley Demonstration Project Rev 2 Attachment C.

Livestock Intakes Phase 1 Decommissioning Plan for Beef: 50 Beef: so Beef: 50 the West Valley Demonstration Water Project Rev 2 Attachment C. There Dairy: 160 Dairy: O Dairy: 0 are no dairy cattle in Area 1. Beef cattle represent deer.

Beef: 14 Beef: 2.25 Beef: 2.25 Phase 1 Decommissioning Plan for the West Valley Demonstration Pasture Project Rev 2 Attachment C. There Dairy: 44 Dairy: 0 Dairy: 0 are no dairy cattle in Area 1. Beef cattle represent deer.

Beef: 54 Beef: O Beef: o Phase 1 Decommissioning Plan for Grain the West Valley Demonstration Project Rev 2 Attachment C. There Dairy: 11 Dairy: 0 Dairy: 0 are no crops in Area 1.

Beef: 0.1 Beef: 0.5 Beef: 0.5 Phase 1 Decommissioning Plan for the West Valley Demonstration Soil from Pasture Project Rev 2 Attachment C. There are no dairy cattle in Area 1. Beef Dairy: 0.4

. Dairy: 0 Dairy: 0 cattle represent deer.

Soil from Grain Beef: 0.4 Beef: O Beef: O Phase 1 Decommissioning Plan for the West Valley Demonstration Page 5 of 6

. l Attachment H3: RESRAD-Offsite 3.1 Inputs Parameters for Area 1 that differ from defaults

  • raramet~r *
RESRAD-Offsite Default
  • Areab2*.
  • AreaU3 Basis:*

Project Rev 2 Attachment C. There Dairy: 0.1 Dairy: 0 Dairy: 0 are no crops in Area 1.

Livestock Feed Factors Pasture: 1.1 Pasture: 1.1 Pasture: 1.1 Grain: 0.7 Grain: 0.7 Grain: 0.7 Phase 1 Decommissioning Plan for Wet weight crop yield Non-leafy: 0.1 Non-leafy: i.75 Non-leafy: 1.75 the West Valley Demonstration Project Rev 2 Attachment c.

Leafy: 1.5 Leafy: 1.5 Leafy: 1.5 Pasture: 20 Pasture: 18 Pasture: 18 Grain: 20 Grain: 18 Grain: 18 Phase 1 Decommissioning Plan for Weathering removal constant Non-leafy: 20 Non-leafy: 18 Non-leafy: 18 the West Valley Demonstration Project Rev 2 Attachment C.

Leafy: 20 Leafy: 18 Leafy: 18 Pasture: 0.25 Pasture: 0.25 Pasture: 0.25 Foliar interception factor for Grain: 0.25 Grain: 0.25 Grain: 0.25 Phase 1 Decommissioning Plan for irrigation Non-leafy: 0.25 Non-leafy: 0.25 Non-leafy: 0.25 the West Valley Demonstration Project Rev 2 Attachment C.

Leafy: 0.25 Leafy: 0.67 Leafy: 0.67 Pasture: 0.9 Pasture: 0.9 Pasture: 0.9 Grain: 1.2 Grain: 0.9 Grain: 0.9 Phase 1 Decommissioning Plan for Root depth Non-leafy: 1.2 Non-leafy: 0.9 Non-leafy: 0.9 the West Valley Demonstration Project Rev 2 Attachment C.

Leafy: 0.9 Leafy: 0.9 Leafy: 0.9 Inhalation and External Gamma Phase 1 Decommissioning Plan for Mass loading 0.0001 0.0000148 0.0000148 the West Valley Demonstration Project Rev 2 Attachment C.

Phase 1 Decommissioning Plan for Indoor to outdoor 0.4 1

1 the West Valley Demonstration Project Rev 2 Attachment c.

External gamma penetrating Phase 1 Decommissioning Plan for factor 0.7 0.273 0.273 the West Valley Demonstration Project Rev 2 Attachment c.

Occupancy 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> per day sleep+ 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> per Primary contamination indoor 0

0.8333 0.8333 day work in the house + 50% of rest of the hours in a year.

Primary contamination outdoor 0

8760 hours0.101 days <br />2.433 hours <br />0.0145 weeks <br />0.00333 months <br /> per year-Primary 0.1667 0.1667 contamination indoor hours per year Offsite dwelling indoor 0.5 0

0 n/a Offsite dwelling outdoor 0.1 0

0 n/a

  • Non-leafy vegetable fields 0.1 0

0 There are no crops in Area 1.

Leafy vegetable fields 0.1 0

0 There are no crops in Area 1.

Pasture are consists of other residential properties. Therefore, Pasture and silage fields 0.1 0

0 an individual would not roam throughout the define pasture area.

Livestock grain fields 0.1 0

0 There are no livestock in Area 1.

Page6of6

..