Radiological Survey and Dose Assessment Report for the Western New York Nuclear Service Center and Off-Site Areas in Follow Up to Aerial Gamma Radiation Survey Conducted in 2014, Rev. 0, Appendix H, Part 2 of 41
ML16294A236
Person / Time
Site: West Valley Demonstration Project, P00M-032
Issue date: 08/22/2016
From:
MJW Technical Services
To:
Office of Nuclear Material Safety and Safeguards, State of NY, Energy Research & Development Authority, Office of Nuclear Reactor Regulation
Shared Package
ML16293A155 List: ... further results
References
Download: ML16294A236 (17)


Text

r-------------

Appendix H2 Soil Analysis

{.

Appendix H2: Soil Analysis WNYNSC

Background:

$aJ)~'ple' N~*
  • oeptn.: **

R~~ul.l: ~-

Uncertainty*

1.sigm~

  • wt.
wrxi* *
  • .Parameter**..

Lab MDL.

~.Units.

BGAl.1.1 Oc15 ALPHA 23.8 4.96 2.48 0.1626 3.8697 3.49 PCl/G BGAl.2.1 0-15 ALPHA 19.7 4.53 2.265 0.1949 3.8400 3.23 PCl/G BGAl.3.1 0-15 ALPHA 11.8 3.23 1.615 0.3834 4.5241 3.61 PCl/G BGAl.4.1 0-15 ALPHA 10.8 3.17 1.585 0.3981 4.2990 3.92 PCl/G BGAl.5.1 0-15 ALPHA 13.2 3.6 1.8 0.3086 4.0741 3.89 PCl/G BGA2.l.1 0-15 ALPHA 9.23 3.11 1.555 0.4136 3.8172 3.78 PCl/G BGA2.2.1 0-15 ALPHA 13 3.73 1.865 0.2875 3.7375 3.89 PCl/G BGA2.3.1 0-15 ALPHA 11.9 3.86 1.93 0.2685 3.1947 3.97 PCl/G BGA2.4.1 0-15 ALPHA 12.5 3.5 1.75 0.3265 4.0816 3.90 PCl/G BGA2.5.l 0-15 ALPHA 8.75 3.18 1.59 0.3956 3.4611 3.99 PCl/G Average:

12.39 1 Sigma:

0.56 o~~ih

' uncett~iritv: 1*rsi~;,:;~_,: *

'Mo{*

<,~ '

-~

$9rtl'ple 'No parameter/* _., iab Result' Wii..

  • WiXi<.. 1

'Ubifs :

BGAl.1.2 15-30 ALPHA 15.8 3.99 1.995 0.2513 3.9698 3.93 PCl/G BGAl.2.2 15-30 ALPHA 17.1 3.52 1.76 0.3228 5.5204 3.36 PCl/G BGAl.3.2 15-30 ALPHA 16.5 3.79 1.895 0.2785 4.5948 3.43 PCl/G BGAl.4.2 15-30 ALPHA 13.6.

3.55 1.775 0.3174 4.3166 3.94 PCl/G BGAl.5.2 15-30 ALPHA 11.4 3.4 1.7 0.3460 3.9446 4.05 PCl/G BGA2.l.2 15-30 ALPHA 6.21 2.78 1.39 0.5176 3.2141 3.75 PCl/G BGA2.2.2 15-30 ALPHA 13.9 3.3 1.65 0.3673 5.1056 3.07 PCl/G BGA2.3.2 15-30 ALPHA 5.2 2.84 1.42 0.4959 2.5789 3.85 PCl/G BGA2.4.2 15-30 ALPHA 10 3.36 1.68 0.3543 3.5431 3.88 PCl/G BGA2.5.2 15-30 ALPHA 12.9 4.02 2.01 0.2475 3.1930 3.92 PCl/G Average:

11.43 1 Sigma:

0.53 BGAl.1.3 30-60 ALPHA 16.5 3.71 1.855 0.2906 4.7951 3.41 PCl/G BGA2.l.3 30-60 ALPHA 12 3.16 1.58 0.4006 4.8069 3.81 PCl/G Average:

13.89 1 Sigma:

1.20 BGAl.1.4 60-100 ALPHA 10.7 3.19 1.595 0.3931 4.2059 3.95 PCl/G BGA2.l.4 60-100 ALPHA 19.7 3.82 1.91 0.2741 5.4001 2.43 PCl/G Average:

14.40 1 Sigma:

1.22 Page 1of16

Appendix H2: Soil Analysis Sample No Depth Parameter Lab Result Uncertainty 1 Sigma Wi WiXi MDL' Units BGAl.1.1 0-15 BETA 24.9 3.46 1.73 0.3341 8.3197 3.81 PCl/G BGAl.2.1 0-15 BETA 23.8 3.42 1.71 0.3420 8.1393 3.91 PCl/G BGAl.3.1 0-15 BETA 21.8 2.94 1.47 0.4628 10.0884 3.45 PCl/G BGAl.4.1 0-15 BETA 20 2.79 1.395 0.5139 10.2774 3.35 PCl/G BGAl.5.1 0-15 BETA 30.3 3.31 1.655 0.3651 11.0623 3.56 PCl/G BGA2.1.1 0-15 BETA 15 2.62 1.31 0.5827 8.7407 3.19 PCl/G BGA2.2.1 0-15 BETA 29.4 3.35 1.675 0.3564 10.4789 3.64 PCl/G BGA2.3.1 0-15 BETA 21.4 3.07 1.535 0.4244 9.0823 2.91 PCl/G BGA2.4.1 0-15 BETA 23.6 3.45 1.725 0.3361 7.9311 4.02 PCl/G BGA2.5.1 0-15 BETA 22.9 2.9 1.45 0.4756 10.8918 2.84 PCl/G Av.erage:

22.66 1 Sigma:

0.49

'sample* No Depth.

Parameter

.Lao Result Wricertaintv. 1 Sigma Wi

.WiXi

    • MDL...Units BGAl.1.2 15-30 BETA 23 3.3 1.65 0.3673 8.4481 3.77 PCl/G BGAl.2.2 15-30 BETA 21.5 2.7 1.35 0.5487 11.7970 2.80 PCl/G BGAl.3.2 15-30 BETA 21.8 2.81 1.405 0.5066 11.0434 3.15 PCl/G BGAl.4.2 15-30 BETA 20 2.67 1.335 0.5611 11.2219 3.04 PCl/G BGAl.5.2 15-30 BETA 20.7 2.9 1.45 0.4756 9.8454 3.22 PCl/G BGA2.1.2 15-30 BETA 16.9 2.73 1.365 0.5367 9.0703 3.25 PCl/G BGA2.2.2 15-30 BETA 17.4 2.86 1.43 0.4890 8.5090 3.53 PCl/G BGA2.3.2 15-30 BETA 17.3 2.8 1.4 0.5102 8.8265 2.62 PCl/G BGA2.4.2 15-30 BETA 20.1 2.9 1.45 0.4756 9.5600 2.83 PCl/G BGA2.5.2 15-30 BETA 25.2 3.3 1.65 0.3673 9.2562 2.97 PCl/G Average:

20.17 1 Sigma:

0.45

),7,..

\\~igma wixr *....

.'"M'bt~:.i,;Units

  • Uncertainty*

Wi*

BGAl.1.3 30-60 BETA 28.9.

3.25 1.625 0.3787 10.9444 3.42 PCl/G BGA2.1.3 30-60 BETA 21.4 2.56 1.28 0.6104 13.0615 2.74 PCl/G Average:

24.27 1 Sigma:

1.01 Sample_No Depth Parameter Lab Result Uncertainty 1 Sigma Wi WiXi MDL Units

  • BGAl.1.4 60-100 BETA 22.5 2.85 1.425 0.4925 11.0803 3.21 PCl/G BGA2.1.4 60-100 BETA 35.2 3.16 1.58 0.4006 14.1003 2.74 PCl/G Average:

28.20 1 Sigma:

1.06 Page 2of16

Appendix H2: Soil Analysis

-'Sam'ple No Depth

  • 'pa'rameter Lab Result* u~certainty 1 Sigma Units
  • Wi WiXi MDL*

BGAl.1.1 0-15 Cesium-137 0.12 0.0534 0.0267 1402.7410 168.3289 0.0683 PCl/G BGAl.2.1 0-15 Cesium-137 0.206 0.0839 0.04195 568.2456 117.0586 0.0956 PCl/G BGAl.3.1 0-15 Cesium-137 0.354 0.0766 0.0383 681.7144 241.3269 0.0703 PCl/G BGAl.4.1 0-15 Cesium-137 0.232 0.0868 0.0434 530.9096 123.1710 0.0891 PCl/G BGAl.5.1 0-15 Cesium-137 0.391 0.0852 0.0426 551.0371 215.4555 0.0851 PCl/G BGA2.1.1 0-15 Cesium-137 0.769 0.127 0.0635 248.0005 190.7124 0.0823 PCl/G BGA2.2.1 0-15 Cesium-137 0.292 0.114 0.057 307.7870 89.8738 0.102 PCl/G BGA2.3.1 0-15 Cesium-137 0.328 0.0933 0.04665 459.5118 150.7199 0.0929 PCl/G BGA2.4.1 0-15 Cesium-137 0.279 0.103 0.0515 377.0384 105.1937

'0.0909 PCl/G BGA2.5.1 0-15 Cesium-137 0.427 0.0877 0.04385 520.0688 222.0694 0.0836 PCl/G Average:

0.29 1 Sigma:

0.01 Sample No Depth

  • P~ra~eter Lab Result Uncertainty 1 sigma wr

"-, wtx'i MDL

0.0435 0.02175 2113.8856 0.0000 0.0915 PCl/G BGAl.2.2 15-30 Cesium-137 0.178 0.092 0.046 472.5898 84.1210 0.0999 PCl/G BGAl.3.2 15-30 Cesium-137 0.299 0.137 0.0685 2B.1174 63.7221 0.136 PCl/G BGAl.4.2 15-30 Cesium-137 0.215 0.0782 0.0391 654.1035 140.6323 0.0609 PCl/G BGAl.5.2 15-30 Cesium-137 0.241 0.079 0.0395 640.9229 154.4624 0.078 PCl/G BGA2.1.2 15-30 Cesium-137 0.0238 0.0366 0.0183 2986.0551 71.0681 0.0753 PCl/G BGA2.2.2 15-30 Cesium-137 0.181 0.0803 0.04015 620.3387 112.2813 0.0989 PCl/G BGA2.3.2 15-30 Cesium-137 0.217 0.0904 0.0452 489.4667 106~2143 0.0654 PCl/G BGA2.4.2 15-30 Cesium-137 0.255 0.0656 0.0328 929.5062 237.0241 0.0605 PCl/G BGA2.5.2 15-30 Cesium-137 0.134 0.0807 0.04035 614.2044 82.3034 0.105 PCl/G Average:

0.11 1 Sigma:

0.01 Depth o<

'L'

  • Pa.ramet~r Lab Re~ult *
  • uni:ertai~tv 1 Si~ma *
  • Wi

-c:-WiXl....

BGA1.1.3 30-60 Cesium-137 0.017 0.0446 0.0223 2010.8991 34.1853 0.0808 PCl/G BGA2.1.3 30-60 Cesium-137

-0.0157 0.0492 0.0246 1652.4555

-25.9436 0.0896 PCl/G Average:

0.00 1 Sigma:

0.02 Sample No Depth.

Parameter.

Lab Result. Uncertainty 1 Sigma Wi WlXi MDL

  • Units BGAl.1.4 60-100 Cesium-137 0.175 0.0599 0.02995 1114.8241 195.0942 0.0849 PCl/G BGA2.1.4 60-100 Cesium-137 0.0611 0.0503 0.02515 1580.9714 96.5974 0.082 PCl/G Average:

0.11 1 Sigma:

0.02' Page 3of16

Appendix H2: Soil Analysis SNI

Background:

All assessments associated with soil sampling are pending based upon a need to more fully characterize the current and future uses of these areas including cultural specific aspects.

Confirmatory Area:

sample NQ Depth Param~ter Lab_Result Uncertainty 1 Sigma.'

MDL*.**.

Units.:

C.1.Cl 0-5 ALPHA 9.44 3.16 1.58 3.84 PCl/G C.2.Cl 0-5 ALPHA 8.06 3.09

.1.545 3.37 PCl/G C.3.Cl 0-5 ALPHA 10.1 3.43 1.715 3.84 PCl/G C.4.Cl 0-5 ALPHA 22.3 5.12 2.56 3.98 PCl/G Sample_:_Nb Depth Parameter Lab_Resul{

Uncertainty:

1 Sigma*

MbL Units :

C.2.C4 30-100 ALPHA 13.1 3.94 1.97 3.96 PCl/G

  • saniple_No Depth
  • Parameter Lab_::Result Uncertainty 1 Sigma

'MDL*.

  • .units
  • C.1.Cl 0-5 BETA 29 2.82 1.41 2.22 PCl/G C.2.Cl 0-5 BETA 20.4 3.4 1.7 3.92 PCl/G C.3.Cl 0-5 BETA 8.69 2.27 1.135 2.71 PCl/G C.4.Cl 0-5 BETA 40.2 4.42 2.21 3.15 PCl/G
Parafo~ter

,.. Lab:_Result. uncertainty' :1 Sigma

. MDl:. *}' * :uniti

  • C.2.C4 30-100 BETA 46.8 4.09 2.045 2.63 PCl/G

.,sample: 1'l9.

Depth Parameter

  • lah"-Besult * ::Uncertainty l'Sigma... MDL'...

ullits~;'*

C.1.Cl 0-5 Cesium-137 1.24 0.141 0.0705 0.0961 PCl/G C.2.Cl 0-5 Cesium-137.

8.68 0.236 0.118 0.0642 PCl/G C.3.Cl 0-5 Cesium-137 0.935 0.214 0.107 0.133 PCl/G C.4.Cl 0-5 Cesium-137 1.41 0.172 0.086 0.13 PCl/G

  • Sample-'No Depth.

Parameter Lab_Result, Uncertainty 1.Sigma Units*

C.2.C4 30-100 Cesium-137 30.2 0.572 0.286 0.0999 PCl/G Page 4of16

Appendix-H2: Soil Analysis Sub-Area L12:

Samp(e No Depth Parameter Lab Result Uncertainty 1 Sigma

.wi WiXi MDL Units 1.1.C.1 0-5 ALPHA 12.6 3.93 1.965 0.2590 3.2632 3.89 PCl/G 1.2.C.1 0-5 ALPHA 7.52 3.29 1.645 0.3695 2.7790 3.92 PCl/G Average:

9.61 1 Sigma:

1.261 sample_No De 0

pth Parameter Lab_)esult Uncertainty 1 Sigma Wi WiXi MDL Units' 1.1.C.2 5-15 ALPHA 9.22 1.49 0.745 1.8017 16.6119 1.62 PCl/G 1.2.C.2 5-15 ALPHA 6.53 1.68 0.84 1.4172 9.2545 2.29 PCl/G Average:

8.04 1 Sigma:

0.557 Sample_No Depth Parameter La.b Result Uncertainty 1 Sigma Wi WiXi MDL Units 1.1.C.1 0-5 BETA 25.5 3.89 1.945 0.2643 6.7406 3.57 PCl/G 1.2.C.1 0-5 BETA 24.5 3.81 1.905 0.2756 6.7511 3.69 PCl/G Average:

24.99 1 Sigma:

1.361 Sample~No Depth Parameter Lab_Result Uncertainty 1 Sigma Wi WiXi MDL Units 1.1.C.2 5-15 BETA 14.3 1.24 0.62 2.6015 37.2008 1.28 PCl/G 1.2.C.2 5-15 BETA 17 1.45 0.725 1.9025 32.3424 1.69 PCl/G Average:

15.44 1 Sigma:

0.471 Sample~No Depth Parameter Lab_Result Uncertainty. 1 Sigma Wi WiXi MDL Units 1.1.C.1 0-5 Cesium-137 3.64 0.256 0.128 61.0352 222.1680 0.108 PCl/G

. 1.2.C.1 0-5 Cesium-137 2.52 0.198 0.099 102.0304 257.1166 0.102 PCl/G Average:

2.94 1 Sigma:

0.078 Sample No Depth Parameter Lab Result Uncertainty 1 Sigma Wi WiXi.

MDL Unit~*

1.1.C.2 5-15 Cesium-137 0.15.

0.0613 0.03065 1064.4838 159.6726 0.0615 PCl/G 1.2.C.2 5-15 Cesium-137 0.143 0.0636 0.0318 988.8849 141.4105 0.0815 PCl/G Average:

0.15 1 Sigma:

  • 0.022 Page 5of16

Appendix H2: Soil Analysis Sub-Area L23:

Sa'niple_:_No bepth

    • 'Parameter
.*lab _Result\\,dJnC:ertainty*.!"Sigma:

wr WiXi

.MDl'.*

Uni.ts 1.3.C.1 0-5 ALPHA 7.84 3.45 1.725 0.3361 2.. 6347 3.97 PCl/G Average:

7.84 1 Sigma:

1.725 Sample_No.

Depth Parameter Lab -Result Uncertainty 1 Sigma*

Wi WiXi MDL.

Units 1.3.C.2 5-15 ALPHA 11.1 2.15 1.075 0.8653 9.6052 2.78 PCl/G Average:

11.1 1 Sigma:

1.075

  • .Sample_No Depth Pa~ameter

.Lab -Result.* *Uncertainty 1 Sigma Wi WiXi MDL Units 1.3.C.1 0-5 BETA 25.6 3.77 1.885 0.2814 7.2047 3.05 PCl/G Average:

25.6 1 Sigma:

1.885 Sample_No

'Depth

Parameter
  • Lab_ResuJt **
  • l:JncertaintV:

1 Sigma Wi

. WiXi

  • 1.3.C.2 5-15 BETA 21.2 1.8 0.9 1.2346 26.1728 2.19 PCl/G Average:

21.2 1 Sigma:

0.900

  • sample_No Depth

. f:la'rameter Lab - Result'

.*uncertain.t~

isigma WI WiXi

'MDL

\\in its 1.3.C.1 0-5 Cesium-137 0.406 0.144 0.072 192.9012 78.3179 0.109 PCl/G Average:

0.406 1 Sigma:

0.072

  • Sample_No Depth Parameter Lab_:_Result.

l:Jncertainty 1 Sigma Wi WiXi MDL LI.hits 1.3.C.2.

5-15 Cesium-137 0.482 0.0947 0.04735 446.0259 214.9845 0.0637 PCl/G Average:

0.482 1 Sigma:

0.047 Sub-Area 2.1:

Sample_No Depth

'Parameter L~b_Result Uncertainty 1 Sigma Wi WiXi MDL Units 2.1.1.R.1 0-5 ALPHA 10.5 3.46 1.73 0.3341 3.5083 3.88.

PCl/G 2.1.2.R.1 0-5 ALPHA 10.3 3.27 1.635 0.3741 3.8530 3.96 PCl/G 2.1.3.R.1 0-5 ALPHA 13.8 3.76 1.88 0.2829 3.9045 3.91 PCl/G 2.1.4.R.1 0-5 ALPHA 9.24 3.19 1.595 0.3931 3.6320 3.92 PCl/G Average:

10.76 1 Sigma:

0.850 Sample_No Depth Parameter Lab_Result Uncertainty 1 Sigma

  • Wi WiXi MDL Units 2.1.3.R.2 5-15 ALPHA 8.03 2.3 1.15 0.7561 6.0718 3.33 PCl/G 2.1.4.R.2 5-15 ALPHA 15.1 3.77 1.885 0.2814 4.2497 3.56 PCl/G Average:

9.95 1 Sigma:

0.982 Page 6of16

Appendix H2: Soil Analysis Sample* No*

Depth*

Parameter **, Lab Result Uncertainty 1 Sigma Wi WiXi MDL Units*

2.1.1.R.1 0-S BETA 15.1 2.51 1.255 0.6349 9.5871 2.48 PCl/G 2.1.2.R.1 0-5 BETA 26.2 3.01 1.505 0.4415 11.5672 3.22 PCl/G 2.1.3.R.1 0-5 BETA 32.2 3.4 1.7 0.3460 11.1419 2.94 PCl/G 2.1.4.R.1 0-5 BETA 26.8 2.95 1.475 0.4596 12.3183 2.71 PCl/G Average:

23.71 1 Sigma:

0.729 sample_'..No Depth Lab~Resuit

uncertainty 1 Sigma Viii WiXi MDL

, Parameter Units 2.1.3.R.2 5-15 BETA 23.1 1.6 0.8 1.5625 36.0938 1.45 PCl/G 2.1.4.R.2 5-15 BETA 27.1 2.91 1.455 0.4724 12.8010 2.75 PCl/G Average:

24.03 1 Sigma:

0.701 sample,_No Depth Parameter Lab__.Result Uncertainty 1 Sigma Wi Wi.Xi MDL Units 2.1.1.R.1 0-5 Cesium-137 0.412 0.161 0.0805 154.3150 63.5778 0.123 PCl/G 2.1.2.R.1 0-5 Cesium-137 0.348 0.169 0.0845 140.0511 48.7378 0.144 PCl/G 2.1.3.R.1 0-5 Cesium-137 0.288 0.0732 0.0366 746.5138 214.9960 0.0982 PCl/G 2.1.4.R.1 0-5 Cesium-137 0.94 0.124 0.062 260.1457 244.5369 0.083 PCl/G Average:

0.44 1 Sigma:

0.028 Sample_No

. Depth Parameter Lab_Result uncertainty 1 Sigma*

Wi WiXi MDL units 2.1.3.R.2 5-15 Cesium-137 0.303 0.0886 0.0443 509.5567 154.3957 0.115 PCl/G 2.1.4.R.2 5-15 Cesium-137 0.829 0.113 0.0565 313.2587 259.6914 0.0977 PCl/G Average:

0.50 1 Sigma:

0.035 Sub-Area 2.2:

Sample No Depth

'Pa~anieter*

Lab. Result Uncertainty 1 Sigma

  • iWi*

WiXi*

, MDL

  • Units 2.2.1.R.1 0-5 ALPHA 17.1 4.43 2.215 0.2038 3.4854 3.95 PCl/G 2.2.2.R.1 0-5 ALPHA 6.47 2.86 1.43 0.4890 3.1640 3.95 PCl/G 2.2.3.R.1 0-5 ALPHA 10.2 3.61 1.805 0.3069 3.1307 3.75 PCl/G 2.2.4.R.1 0-5 ALPHA 12.8 3.89 1.945 0.2643 3.3835 3.96 PCl/G Average:

10.41 1 Sigma:

0.889 Sam.pl(_ No Depth Parameter

'Lab~Result uncertainty "1 Sigma Wi WiXi MDL units*

2.2.1.R.2 5-15 ALPHA 10 3.26 1.63 0.3764 3.7638 3.92 PCl/G 2.2.2.R.2 5-15 ALPHA 7.09 2.89 1.445 0.4789 3.3956 3.90 PCl/G 2.2.3.R.2 5-15 ALPHA 6.74 2.93 1.46~

0.4659 3.1404 3.90 PCl/G 2.2.4.R.2 5-15 ALPHA 10.2 3.1 1.55 0.4162 4.2456 3.93 PCl/G Average:

8.37 1 Sigma:

0.759 Sample_No Depth Parameter Lab_:Result uncertainty 1 Sigma Wi WiXi MDL units 2.2.4.R.3 15-100 ALPHA 12.5 2.01 1.005 0.9901 12.3759 2.29 PCl/G Average:

12.5 1 Sigma:

1.005 Page 7of16

Appendix H2: Soil Analysis

. Sample No Depth' fiarameter Lab Result Uncertainty 1 Sigma'.

Wi WiXi MDL

  • bnits '

2.2.1.R.1 0-5 BETA 29.2 3:85 1.925 0.2699 7.8799 3.28 PCl/G 2.2.2.R.l 0-5 BETA 16.4 3.07 1.535 0.4244 6.9603 4.01 PCl/G 2.2.3.R.1 0-5 BETA 24.7 4.05 2.025 0.2439 6.0235 4.19 PCl/G 2.2.4.R.l 0-5 BETA 28.2 4.34 2.17 0.2124 5.9887 4.84 PCl/G Average:

23.34 1 Sigma:

0.932 Sample No Depth Parameter Lab Result uncertainty 1 Sigma Wi WiXi Units MDL 2.2.1.R.2 5-15 BETA 18.6 2.67 1.335 0.5611 10.4364 2.77 PCl/G 2.2.2.R.2 5-15 BETA 12.7 2.32 1.16 0.7432 9.4382 2.74 PCl/G 2.2.3.R.2 5-15 BETA 8.37 2.24 1.12 0.7972" 6.6725 2.85 PCl/G 2.2.4.R.2 5-15 BETA 15.7 2.85 1.425 0.4925 7.7316 3.69 PCl/G Average:

13.22 1 Sigma:

0.621 Sample_No Depth Parameter Lab~Result Uncertainty, 1 Sigma Wi WiXi MDI Units 2.2.4.R.3 15-100 BETA 18.4 1.34 0.67 2.2277 40.9891 1.40 PCl/G Average:

18.4 1 Sigma:

0.670 Sample_No

. Depth'.

    • Pa~ameter **
  • Lab.'._Result
  • uric~rtainty l'Sigma*.

,Wi

    • WiXi

'. MDL° Units 2.2.1.R.1 0-5 Cesium-137 1.42 0.147 0.0735 185.1081 262.8534 0.0859 PCl/G 2.2.2.R.1 0-5 Cesium-137 1.4 0.165 0.0825 146.9238 205.6933 0.0946 PCl/G 2.2.3.R.1 0-5 Cesium-137 2.15 0.16 0.08 156.2500 335.9375 0.0822 PCl/G 2.2.4.R.1 0-5 Cesium-137 1.78 0.189 0.0945 111.9789 199.3225 0.0927 PCl/G Average:

1.67 1 Sigma:

0.041 Sample_No Depth Parameter Lab Result' uncertainty 1 Sigma.

  • wi WiXi.*.*.

MDL uriits 2.2.1.R.2 5-15 Cesium-137 0.317 0.0777 0.03885 662.5489 210.0280 0.0775 PCl/G 2.2.2.R.2 5-15 Cesium-137 0.27 0.0768 0.0384 678.1684 183.1055 0.082 PCl/G 2.2.3.R.2 5-15 Cesium-137 0.26 0.0887 0.04435 508.4084 132.1862 0.122 PCl/G 2.2.4.R.2 5-15 Cesium-137 0.193 0.0635 0.03175 992.0020 191.4564 0.0685 PCl/G Average:

0.25 1 Sigma:

0.019 SamplejJo Depth.

  • fiarameter Lab_Re~ult Uncertainty 1 Sigma Wi WiXi MDL

0.0445 0.02225 2019.9470 0.0000 0.0649 PCl/G Average:,

0 1 Sigma:

0.022 Page 8of16

Appendix H2: Soil Analysis Sub-Area. 3.1:

Sample No D_epth

Parameter Lab Result Uncertainty 1 Sigma Wi WiXi MD,L.
  • Units 3.1.1.E.1 0-15 ALPHA 18.4 2.S2 1.26 0.6299 11.5898 2.56 PCl/G 3.1.2.E.1 0-15 ALPHA 17 2.33 1.165 0.7368 12.5256 2.32 PCl/G 3.1.3.E.1 0-15 ALPHA 14.3 2.07 1.035 0.9335 13.3492 2.38 PCl/G
  • 3.1.4.R.l 0-15 ALPHA 11.5 1.87 0.935 1.1439 13.1545 2.13 PCl/G 3.1.5.R.1 0-15 ALPHA 12.5 1.91 0.955 1.0965 13.7058 2.08 PCl/G 3.1.6.R.1 0-15 ALPHA 10.8 4.44 2.22 0.2029 2.1914 3.79 PCl/G 3.1.7.R.1 0-15 ALPHA 10.1 3.56 1.78 0.3156 3.1877 3.48 PCl/G 3.1.8.R.1 0-15 ALPHA 10.1 3.17 1.585 0.3981 4.0203 3.60 PCl/G 3.1.9.E.1 0-15 ALPHA 14.9 4.08 2.04 0.2403 3.5804 3.69.

PCl/G 3.1.10.E.1 0-15 ALPHA 12.8 3.99 1.995 0.2513 3.2161 3.97 PCl/G 3.1.11.E.1 0-15 ALPHA 13.8 3.32 1.66 0.3629 5.0080 3.46 PCl/G 3.1.12.E.1 0-15 ALPHA 16.3 3.98 1.99 0.2525 4.1161 3.95 PCl/G 3.1.13.R.1 0-15 ALPHA 8.17 2.26 1.13 0.7831 6.3983 2.68 PCl/G 3.1.14.R.1 0-15 ALPHA 9.96 3.08 1.54 0.4217 4.1997 3.99 PCl/G 3.1.15.R.1 0-15 ALPHA 13.1 3.19 1.595 0.3931 5.1493 3.76 PCl/G 3.1.16.R.1 0-15 ALPHA 14.7 3.55 1.775 0.3174 4.6657 3.98 PCl/G 3.1.17.R.1 0-15 ALPHA 11.8 2.94 1.47 0.4628 5.4607 3.46.

PCl/G 3.1.18.R.1 0-15 ALPHA 7.56 2.42 1.21 0.6830 5.1636 3.21 PCl/G 3.1.19.R.1 0-15 ALPHA 14.7 3.57 1.785 0.3139 4.6136 3.83 PCl/G 3.1.20.R.1 0-15 ALPHA 15.1 3.49.

1.745 0.3284 4.9589 3.10 PCl/G 3.1.21.R.1 0-15 ALPHA 8.73 2.97 1.485 0.4535 3.9588 3.65 PCl/G 3.1.22.R.l 0-15 ALPHA 14.9 3.2 1.6 0.3906 5.8203 2.53 PCl/G 3.1.23.R.1 0-15 ALPHA 12.4 3.09 1.545 0.4189 5.1948 2.55 PCl/G 3.1.24.R.1 0-15 ALPHA 12.4 3.69 1.845 0.2938 3.6427 3.42 PCl/G Average:

12.59 1 Sigma:

0.291 Page 9of16

Appendix H2: Soil Analysis Scimple No Depth Parameter

, Lab_Result. Uncertainty 1 Sigma Wi WiXi MDL Units 3.1.1.E.2 15-30 ALPHA 13.2 2.26 1.13 0.7831 10.3375 2.59 PCl/G 3.1.2.E.2 15-30 ALPHA 21.1 2.71 1.355 0.5447 11.4922 2.94 PCl/G 3.1.3.E.2 15-30 ALPHA 18 2.24 1.12 0.7972 14.3495 2.30 PCl/G 3.1.4.R.2 15-.30 ALPHA 14.7 2.08 1.04 0.9246 13.5910 2.16 PCl/G 3.1.5.R.2 15-30 ALPHA 13.4 4.47 2.235 0.2002 2.6826 3.86 PCl/G 3.1.6.R.2 15-30 ALPHA 10.8 3.83 1.915 0.2727 2.9450 3.85 PCl/G 3.1.7.R.2 15-30 ALPHA 19.5 6.16 3.08 0.1054 2.0556 3.54 PCl/G 3.1.8.R.2 15-30 ALPHA 17.8 4.94 2.47 0.1639 2.9176 3.88 PCl/G 3.1.9.E.2 15-30 ALPHA 16.8 4.88 2.44 0.1680 2.8218 3.80 PCl/G 3.1.10.E.2 15-30 ALPHA 9.23 3.22 1.61 0.3858 3.5608 3.99 PCl/G 3.1.11.E.2 15-30 ALPHA 12.4 3.64 1.82 0.3019 3.7435 3.93 PCl/G 3.1.12.E.2 15-30 ALPHA 13.2 3.71 1.855 0.2906 3.8361 3.89 PCl/G 3.1.13.R.2 15-30 ALPHA 11.9 3.81 1.905 0.2756 3.2791 3.99 PCl/G 3.1.14.R.2 15-30 ALPHA 9.16 3.18 1.59 0.3956 3.6233 3.99 PCl/G 3.1.15.R.2 15-30 ALPHA 18.5 4.07 2.035 0.2415 4.4673 3.95 PCl/G 3.1.16.R.2 15-30 ALPHA 8.99 3.55 1.775 0.3174 2.8534 3.91 PCl/G 3.1.17.R.2 15-30 ALPHA 10.2 3.81 1.905 0.2756 2.8107 3.82 PCl/G 3.1.18.R.2 15-30 ALPHA 11.5 3.28 1.64 0.3718 4.2757 3.91 PCl/G 3.1.19.R.2 15-30 ALPHA 7.32 3.21 1.605 0.3882 2.8416 3.70 PCl/G 3.1.21.R.2 15-30 ALPHA 13.3 4.01 2.005 0.2488 3.3084 3.78 PCl/G 3.1.22.R.2.

15-30 ALPHA 16.8 4.32 2.16 0.2143 3.6008 3.86 PCl/G 3.1.23.R.2 15-30 ALPHA 14.4 4.45 2.225 0.2020 2.9087 3.91 PCl/G 3.1.24.R.2 15-30 ALPHA 11.5 3.78 1.89 0.2799 3.2194 3.87 PCl/G Average:

13.69 1 Sigma:

0.350 Saryiple~No Depth,

.. Pararneter Lab~Result :. : Uncertair).ty 1 Sigma,; :

. Wi*

.\\ WiXi.

MDL Units 3.1.1.E.3 30-60 ALPHA 16.3 2.11 1.055 0.8985 14.6448 1.97 PCl/G Average:

16.3 1 Sigma:

1.055

  • s'ample~Nq:

D~pth.

P~ranieter Lab_:.Result * :uncertainty 1siiim'ci Wi WiXL"'

MDL 1Units 3.1.1.E.4 60-100 ALPHA 14.5 3.59 1.795 0.3104 4.5003 2.85 PCl/G 3.1.2.E.4 60-100 ALPHA 15.4 2.07 1.035 0.9335 14.3761 2.11 PCl/G 3.1.3.E.4 60-100 ALPHA 12.8 1.84 0.92 1.1815 15.1229 1.79 PCl/G 3.1.4.R.4 60-100 ALPHA 13.1 1.89 0.945 1.1198 14.6692 2.05 PCl/G Average:

13.7 1 Sigma:

0.531 Page 10of16

Appendix H2: Soil Analysis

.sample No" Depth' Parameter Lab Result Uncertainty'

  • 1 Sigm~

. Wi WiXi MDL Units 3.1.1.E.1 0-15 BETA 27.7 1.76 0.88 1.2913 35.7696 1.72 PCl/G 3.1.2.E.1 0-15 BETA 28.1 1.79 0.895 1.2484 35.0801 1.65 PCl/G 3.1.3.E.1 0-15 BETA 22.1 1.44 0.72 1.9290 42.6312 1.20 PCl/G 3.1.4.R.1 0-15 BETA 20.8 1.99 0.995 1.0101 21.0096 2.65 PCl/G 3.1.5.R.l 0-15 BETA 20.5 1.65 0.825 1.4692 30.1194 1.82 PCl/G 3.1.6.R.1 0-15 BETA 15.3 3.82 1.91 0.2741 4.1940 4.05 PCl/G 3.1.7.R.l 0-15 BETA 25.2 3.5 1.75 0.3265 8.2286 2.93 PCl/G 3.1.8.R.1 0-15 BETA 21.3 3.21 1.605 0.3882 8.2686 3.97 PCl/G 3.1.9.E.1 0-15 BETA 11.6 2.53 1.265 0.6249 7.2490 2.58 PCl/G 3.1.10.E.1 0-15 BETA 21.5 3.74 1.87 0.2860 6.1483 4.48 PCl/G 3.1.11.E.1 0-15 BETA 21 2.81 1.405 0.5066 10.6382 3.25 PCl/G 3.1.12.E.1 0-15 BETA 26.4 3.4 1.7 0.3460 9.1349 4.01 PCl/G 3.1.13.R.1 0-15 BETA 16.3 2.09 1.045 0.9157 14.9264 2.47 PCl/G 3.1.14.R.1 0-15 BETA 20 2.46 1.23 0.6610 13.2196 3.06 PCl/G 3.1.15.R.1 0-15 BETA 21.7 2.71 1.355 0.5447 11.8190 3.36 PCl/G 3.1.16.R.1 0-15 BETA 21.1 2.59 1.295 0.5963 12.9396 2.91 PCl/G 3.1.17.R.1 0-15 BETA 24.4 2.64 1.32 0.5739 14.0037 3.11 PCl/G 3.1.18.R.1 0-15 BETA 23.5 2.39 1.195 0.7003 16.4563 2.63 PCl/G 3.1.19.R.1 0-15 BETA 19.9 2.73 1.365 0.5367 10.6804 3.13 PCl/G 3.1.20.R.1 0-15 BETA 21.6 2.76 1.38 0.5251 11.3422 3.03 PCl/G 3.1.21.R.1 0-15 BETA 23 3.05 1.525 0.4300 9.8898 3.31 PCl/G 3.1.22.R.l 0-15 BETA 25.4 3.09 1.545 0.4189 10.6409 3.20 PCl/G 3.1.23.R.1

  • 0-15 BETA 22.8 3.44 1.72 0.3380 7.7069 4.23 PCl/G 3.1.24.R.1 0-15 BETA 21.2 3.25 1.625 0.3787 8.0284 3.39 PCl/G Average:

22.07 1 Sigma:

0.248 Page 11of16

Appendix H2: Soil Analysis Sample No Depth Parameter lab Result Uncertainty 1 Sigma 3.1.1.E.2 15-30 BETA 25.7 1.68 0.84 3.1.2.E.2 15-30 BETA 27.8 1.76 0.88 3.1.3.E.2 15-30 BETA 28.5 2.05 1.025 3.1.4.R.2 15-30 BETA 22.7 1.71 0.855 3.1.5.R.2 15-30 BETA 25.8 3.69 1.845 3.1.6.R.2 15-30 BETA 30.2 3.66 1.83 3.1.7.R.2 15-30 BETA 25.7 4.32 2.16 3.1.8.R.2 15-30 BETA 27.8 4

2 3.1.9.E.2 15-30 BETA 28.2 4.16 2.08 3.1.10.E.2 15-30 BETA 22.4 2.95 1.475 3.1.11.E.2 15-30 BETA 23.1 3.44 1.72 3.1.12.E.2 15-30 BETA 26.2 3.18 1.59 3.1.13.R.2 15-30 BETA 21.9 2.9 1.45 3.1.14.R.2 15-30 BETA 19.6 2.47 1.235 3.1.15.R.2 15-30 BETA 23.7 2.89 1.445 3.1.16.R.2 15-30 BETA 17 2.71 1.355 3.1.17.R.2 15-30 BETA 17.9 3.27 1.635 3.1.18.R.2 15-30 BETA 17.3 2.52 1.26 3.1.19.R.2 15-30 BETA 17.8 3

1.5 3.1.21.R.2 15-30 BETA 24.1 3.57 1.785 3.1.22.R.2 15-30 BETA 30.8 3.49 1.745 3.1.23.R.2 15-30 BETA 24.2 3.26 1.63 3.1.24.R.2 15-30 BETA 22.3 3.36 1.68 Average:

23.92 1 Sigma:

0.283 sample.:_No D~pth Parameter Lab,_Result..

Uncertainty' lSigina *~'

3.1.1.E.3 30-60 BETA 23.2 1.54 0.77 Average:

23.2 1 Sigma:

0.770 Sarnple_No Depth Param.eter

  • Lab* Result*

Uncertainty 1 Sigma 3.1.1.E.4 60-100 BETA 21.6 2.76 1.38 3.1.2.E.4 60-100 BETA 26.5 1.88 0.94 3.1.3.E.4 60-100 BETA 26 1.75 0.875 3.1.4.R.4 60-100 BETA 20.2 1.42 0.71 Average:

23.3 1 Sigma:

0.450 Page 12of16 Wi WiXi 1.4172 36.4229 1.2913 35.8988 0.9518 27.1267 1.3679 31.0523 0.2938 7.5793 0.2986 9.0179 0.2143 5.5084 0.2500 6.9500 0.2311 6.5181 0.4596 10.2959 0.3380 7.8083 0.3956 10.3635 0.4756 10.4162 0.6556 12.8506 0.4789 11.3504 0.5447 9.2591 0.3741 6.6960 0.6299 10.8970 0.4444 7.9111 0.3139 7.5638 0.3284 10.1149 0.3764 9.1084 0.3543 7.9011

  • ~ Wi wixi.

1.6866 Wi Wi~i -

0.5251 11.3422 1.1317 29.9909 1.3061 33.9592 1.9837 40.0714 MDL 1.68 1.75 2.51 1.82 2.84 2.21 2.98 3.97 3.88 3.27 4.18 2.87 2.54 2.29 2.82 2.56 2.92 2.77 2.86 3.40 2.56 2.30 3.35

MDL;'

1.57 MDL 2.85 2.13 1.76 1.35 Units PCl/G PCl/G PCl/G PCl/G PCl/G PCl/G PCl/G PCl/G

. PCl/G PCl/G PCl/G PCl/G PCl/G PCl/G PCl/G PCl/G PCl/G PCl/G PCl/G PCl/G PCl/G PCl/G PCl/G

. units**

PCl/G Units PCl/G PCl/G PCl/G PCl/G j

Appendix H2: Soil Analysis

.sample *No Depth Parameter

  • Lab Result

'Uncertainty' 1 Sigma

"*Wi WiXi

.'MDL Units 3.1.1.E.l 0-15 Cesium-137 1.23 0.144 0.072 192.9012 237.2685 0.0838 PCl/G 3.1.2.E.1 0-15 Cesium-137 1.29 0.178 0.089 126.2467 162.8582 0.140 PCl/G 3.1.3.E.l 0-15 Cesium-137 1.24 0.122 0.061 268.7450 333.2438 0.0719 PCl/G 3.1.4.R.1 0-15 Cesium-137 0.762 0.0927 0.04635 465.4795 354.6953 0.0697 PCl/G 3.1.5.R.l 0-15 Cesium-137 1.11 0.124 0.062 260.1457 288.7617 0.0731 PCl/G 3.1.6.R.1 0-15 Cesium-137 1.04 0.092 0.046 472.5898 491.4934 0.0633 PCl/G 3.1.7.R.1 0-15 Cesium-137 1.17 0.175 0.0875 130.6122 152.8163 0.103 PCl/G 3.1.8.R.1 0-15 Cesium-137 0.952 0.13?

0.0685 213.1174 202.8877 0.105 PCl/G 3.1.9.E.1 0-15 Cesium-137 1.36 0.157 0.0785 162.2784 220.6986 0.105 PCl/G 3.1.10.E.1 0-15 Cesium-137 1.16 0.156 0.078 164.3655 190.6640 0.0979 PCl/G 3.1.11.E.1 d-15

  • Cesium-137 0.984 0.0988 0.0494 409.7756 403.2192 0.0738 PCl/G 3.1.12.E.1 0-15 Cesium-137 1.05 0.12 0.06 277.7778 291.6667 0.0736 PCl/G 3.1.13.R.1 0-15 Cesium-137 0.966 0.126 0.063 251.9526 243.3862 0.107 PCl/G 3.1.14.R.l 0-15 Cesium-137 1.36 0.128 0.064 244.1406 332.0313 0.085 PCl/G 3.1.15.R.1 0-15 Cesium-137 1.28 0.158 0.079 160.2307 205.0953 0.0961 PCl/G 3.1.16.R.l 0-15 Cesium-137 1.75 0.161 0.0805 154.3150 270.0513 0.0756 PCl/G 3.1.17.R.1 0-15 Cesium-137 0.935 0.133 0.0665 226.1292 211.4308 0.0906 PCl/G 3.1.18.R.1 0-15 Cesium-137 1.12 0.127 0.0635 248.0005 277.7606 0.0633 PCl/G 3.1.19.R.1 0-15 Cesium-137 1.07 0.109 0.0545 336.6720 360.2390 0.0739 PCl/G 3.1.20.R.l 0-15 Cesium-137 0.414 0.089 0.0445

. 504.9867 209.0645 0.0777 PCl/G 3.1.21.R.1 0-15 Cesium-137 0.824 0.112 0.056 318.8776 262.7551 0.086 PCl/G 3.1.22.R.1 0-15 Cesium-137 1.15 0.121 0.0605 273.2054 314.1862 0.0595 PCl/G 3.1.23.R.1 0-15 Cesium-137 1.39 0.155 0.0775 166.4932 231.4256 0.116 PCl/G 3.1.24.R.1 0-15 Cesium-137 1.65 0.12 0.06 277.7778 458.3333 0.0529 PCl/G Average:

1.06 1 Sigma:

0.013 Page 13of16

Appendix H2: Soil Analysis Sample No Depth Pa'rameter.,.

Lab Result. Uncertainty. 1 Sigma

.W.i.

"WiXi

. MDL Units 3.1.1.E.2 15-30 Cesium-137 1.94 0.184 0.092 118.1474 229.2060 0.0985 PCl/G 3.1.2.E.2 15-30 Cesium-137 2.83 0.202 0.101 98.0296 277.4238 0.0876 PCl/G 3.1.3.E.2 15-30 Cesium-137 1.54 0.159 0.0795 158.2216 243.6612 0.121 PCl/G 3.1.4.R.2 15-30 Cesium-137 1.13 0.12 0.06 277.7778 313.8889 0.0632 PCl/G 3.1.5.R.2 15-30 Cesium-137 0.94' 0.14 0.07 204.0816 191.8367 0.0887' PCl/G 3.1.6.R.2 15-30 Cesium-137 2.52 0.19 0.095 110.8033 279.2244 0.0834 PCl/G 3.1.7.R.2 15-30 Cesium-137 0.869 0.142 0.071 198.3733 172.3864 0.0946 PCl/G 3.1.8.R.2 15-30 Cesium-137 0.972 0.117 0.0585 292.2054 284.0237 0.0796 PCl/G 3.1.9.E.2 15-30 Cesium-137 1.85 0.178 0.089 126.2467 233.5564 0.113 PCl/G 3.1.10.E.2 15-30 Cesium-137 1.45 0.167 0.0835 143.4257 207.9673 0.0872 PCl/G 3.1.11.E.2 15-30 Cesium-137 1.35 0.136 0.068 216.2630 291.9550 0.0821 PCl/G 3.1.12.E.2 15-30 Cesium-137 1.43 0.117 0.0585 292.2054 417.8538 0.0674 PCl/G 3.1.13.R.2 15-30 Cesium-137 0.991 0.123 0.0615 264.3929 262.0134 0.0733 PCl/G 3.1.14.R.2 15-30 Cesium-137 1.27 0.0964 0.0482 430.4334 546.6504 0.0564 PCl/G 3.1.15.R.2 15-30 Cesium-137 1.72 0.14 0.07 204.0816 351.0204 0.090 PCl/G 3.1.16.R.2 15-30 Cesium-137 2.48 0.176 0.088 129.1322 320.2479 0.074 PCl/G 3.1.17.R.2 15-30 Cesium-137 0.742 0.107 0.0535 349.3755 259.2366 0.0879 PCl/G 3.1.18.R.2 15-30 Cesium-137 1.83 0.16 0.08 156.2500 285.9375 0.0837 PCl/G 3.1.19.R.2 15-30 Cesium-137 1.46 0.152 0.076 173.1302 252.7701 0.0917 PCl/G 3.1.21.R.2 15-30 Cesium-137 1.24 0.122 0.061 268.7450 333.2438 0.0765 PCl/G 3.1.22.R.2 15-30 Cesium-137 1.37 0.178 0.089 126.2467 172.9580 0.111 PCl/G 3.1.23.R.2 15-30 Cesium-137 1.64 0.161 0.0805 154.3150 253.0767 0.0903 PCl/G 3.1.24.R.2 15-30 Cesium-137 1.56 0.17 0.085 138.4083 215.9170 0.096 PCl/G Average:

1.38 1 Sigma:

0.015

. Satnple_No

  • Depth Pa.rameter Lab Result Uncertainty 1 sigma

'Wi

'WiXi MDL Units 3.1.1.E.3 30-60 Cesium-137 2.18 0.173 0.0865 133.6496 291.3562 0.0805 PCl/G Average:

2.18 1 Sigma:

0.087

  • Sample No
  • Uncertainty.* i Sigma....... 'Wf...

WiXi

. ' iVfDL *:

units Defpth

. -Parameter,

~ab Result *

~

3.1.1.E.4 60-100 Cesium-137 0.315 0.0979 0.04895 417.3444 131.4635 0.0869 PCl/G 3.1.2.E.4 60-100 Cesium-137 0

0.0628 0.0314 1014.2399 0.0000 0.134 PCl/G 3.1.3.E.4 60-100 Cesium-137 0.178 0.091 0.0455 483.0335 85.9800 0.0874 PCl/G 3.1.4.R.4 60-100 Cesium-137 0.821 0.0951 0.04755 442.2817 363.1133 0.064 PCl/G Average:

0.246 1 Sigma:

0.021 Sub-Area 3.2:

Sample No ciepth Pa.rameter Lab Res.ult uncertainty

!sigma Wi WiXi.

MDL.

Units 3.2.1.R.1 0-15 ALPHA 14.7 4.11 2.055 0.2368 3.4809 3.45 PCl/G 3.2.2.R.1 0-15 ALPHA 12.6 3.79 1.895 0.2785 3.5087 3.83 PCl/G 3.2.3.R.1 0-15 ALPHA 15.1 4.45 2.225 0.2020 3.0501 3.90 PCl/G 3.2.4.R.1 0-15 ALPHA 10.3 3.6 1.8 0.3086 3.1790 3.90 PCl/G Average:

12.89 1 Sigma:

0.987

. Page 14 of 16

Appendix H2: Soil Analysis

. Sample.:_No. * " Depth Pa_rameter,

  • Lab_Result Uncertainty l'Sigma Wi*

WiXi MDL Units 3.2.4.R.3 30-60 ALPHA 11.5 3.65 1.825 0.3002 3.4528 3.82 PCl/G Average:

11.5 1 Sigma:

1.825

  • sarriple_:_No Depth

'Parameter Lab_Result Uncertainty i Sigma Wi Units 3.2.4.R.4 60-100 ALPHA 7.79 3.14 1.57 0.4057 PCl/G Average:

7.79 1 Sigma:

1.570

  • Sample_Nci *' 'Dep~h Parameter Lab Result Uncertainty 1 Sigma, WiXi.

MDL.

Units Wi 3.2.1.R.l 0-15 BETA 22.9 3.59 1.795 0.3104 7.1073 3.73 PCl/G 3.2.2.R.1 0-15 BETA 18.5 2.88 1.44 0.4823 8.9217 2.64 PCl/G 3.2.3.R.1 0-15 BETA 15 3.82 1.91 0.2741 4.1117 4.91 PCl/G 3.2.4.R.1 0-15 BETA 19.1 3.1 1.55 0.4162 7.9501 2.93 PCl/G Average:

18.94 1 Sigma:

0.821 sample~No Depth Parameter Lab_Resulf Uncertainty 1 Sigma Wi WiXi MDL Units 3.2.4.R.3 30-60 BETA 19.4 3.13 1.565 0.4083 7.9209 3.13 PCl/G Average:

19.4 1 Sigma:

1.565 Sample_No DeP,th,

.Par(lmeter Lali_Result Uncertainty 1 Sigma

.,MDL

, Units 3.2:4.R.4 60-100 BETA 22.1 3.13 1.565 3.06 PCl/G Average:

22.1 1 Sigma:

1.565 Sa"r:nple' No Depth "

  • Paranieter Lab Result.

Uncertainty, 1 Sigma

  • Wi' WiXi.

'MDL Units*

3.2.1.R.1 0-15 Cesium-137 0.468 0.126 0.063 251.9526 117.9138 0.0895 PCl/G 3.2.2.R.1 0-15 Cesium-137 0.597 0.0934 0.0467 458.5284 273.7415 0.0888 PCl/G 3.2.3.R.1 0-15 Cesium-137 0.527 0.0938 0.0469 454.6260 239.5879 0.0788 PCl/G 3.2.4.R.1 0-15 Cesium-137 0.556 0.0885 0.04425 510.7089 283.9542 0.0692 PCl/G Average:

0.546 1 Sigma:

0.024

Sample.::_No

.Depth :*

'Parameter:

Lab - Result**

Uncertainty' 1 Sigma

  • Wi
  • 'WiXL" MbL',

Units 3.2.4.R.3 30-60 Cesium-137 0.129 0.0839 0.04195 568.2456 73.3037 0.105 PCl/G Average:

0.129 1 Sigma:

0.042 Sample_NO., Depth Parameter Lab_Resuit Uncertainty 1 Sigma wi WiXi MDL U_nits 3.2.4.R.4 60-100 Cesium-137 0.0806 0.0521 0.02605 1473.6167 118.7735 0.0878 PCl/G Average:

0.0806 1 Sigma:

0.026 Page 15of16

Appendix H2: Soil Analysis Area 4:

All assessments associated with soil sampling are pending based upon a need to more fully characterize the current and future uses of these areas including cultural specific aspects.

Area 5:

All assessments associated with soil sampling are pending based upon a need to more fully characterize the current and future uses of these areas including cultural specific aspects.

Confirmatory Area 5arnple:...N9 Parameter Unc~rtainty Depth:

Lab.:_Result 1 Sigma.:

Wi WiXi MDL Units C.1.Cl 0-5 ALPHA 9.44 3.16 1.58 0.40 3.78 3.84 PCl/G C.2.Cl 0-5 ALPHA 8.06 3.09 1.545 0.42 3.38 3.37 PCl/G C.3.Cl 0-5 ALPHA 10.1 3.43 1.715 0.34 3.43 3.84 PCl/G C.4.Cl 0-5 ALPHA 22.3 5.12 2.56 0.15 3.40 3.98 PCl/G Average:

10.67 1 Sigma:

0.87 sample_fio Depth.

Parameter La:b _.:.Resu It

  • Umcertainty 1Sigma
  • .Wi WiXb'

. MD.L'.

.-:units C.2.C4 30-100 ALPHA 13.1 3.94 1.97 0.26 3.38 3.96 PCl/G Average:

13.10 1 Sigma:

1.97 Sample No

  • Depth Paran;ieter Lab Result.* Uncertainty. 1 Sigma IJJi WiXi*
'MDL Units C.1.Cl 0-5 BETA 29 2.82 1.41 0.50 14.59 2.22 PCl/G C.2.Cl 0-5 BETA 20.4 3.4 1.7 0.35 7.06 3.92 PCl/G C.3.Cl 0-5 BETA 8.69 2.27 1.135 0.78 6.75.

2.71 PCl/G C.4.Cl 0-5 BETA 40.2 4.42 2.21 0.20 8.23 3.15 PCl/G Average:

20.01 15igma:

0.74 5ampl(}io Depth Pa.rarneter Lab_Result

, Uncertainty 1 Sigma Wi..

WiXi MDL Units C.2.C4 30-100 BETA 46.8 4.09 2.045 0.24 11.19 2.63 PCl/G Average:

46.80 1 Sigma:

2.05 Sample No Deptb P.arameter Lab Result U rice rta i nty.1 Sigma Wi WiXi MD[

Units C.1.Cl 0-5 Cesium-137 1.24 0.141 0.0705 201.20 249.48 0.0961 PCl/G C.2.Cl 0-5 Cesium-137 8.68 0.236 0.118 71.82 623.38 0.0642 PCl/G C.3.Cl 0-5 Cesium-137 0.935 0.214 0.107 87.34 81.67 0.133 PCl/G C.4.Cl 0-5 Cesium-137 1.41 0.172 0.086 135.21 190.64 0.13 PCl/G Average:

2.31 1 Sigma:

0.04

.Sample_:No Depth parameter..

  • Lab_Result Uncertainty 1 Sigma Wi Wi:Xi MDL
  • .Units C.2.C4 30-100 Cesium-137 30.2 0.572 0.286 12.23 369.21 0.0999 PCl/G Average:

30.20 1 Sigma:

0.29 Page 16of16