2807 West County Road 75 Monticello, MN 55362 (l Xcel Energy RES P 0 N S I B L E B V NAT U R E" 800.895.4999 xcelenergy.com October 20, 2016 L-MT-16-035 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Monticello Nuclear Generating Plant Docket No. 50-263 Renewed Facility Operating License No. DPR-22 Corrections to 2011. 2012. 2013. and 2014 Annual Radiological Environmental Operating Reports This letter submits changes to the 2011, 2012, 2013, and 2014 Annual Radiological Environmental Operating Reports (AREORs). The changes do not impact the conclusions of the reports. Four Enclosures attached to this letter identify the specific corrections, affected pages, and the corrected pages in their entirety.
If you have any questions concerning this information, please contact Mr. Stephen Sollom at (763) 295-1611.
Summary of Commitments This letter makes no new commitments and no revisions to existing commitments.
~~
Peter A. Gardner Site Vice President, Monticello Nuclear Generating Plant Northern States Power Company- Minnesota
L-MT-16-035 Document Control Desk Page 2
Enclosures:
- Corrections to the 2011 AREOR Attachment 1: Replacement pages for 2011 AREOR Attachment 2: Additional pages for the 2011 AREOR : Corrections to the 2012 AREOR Attachment 1: Replacement pages for 2012 AREOR Attachment 2: Additional pages for the 2012 AREOR : Corrections to the 2013 AREOR Attachment 1: Replacement pages for the 2013 AREOR : Correction to the 2014 AREOR Attachment 1: Replacement pages for the 2014 AREOR cc: Administrator, Region III, USNRC Project Manager, Monticello, Resident Inspector, Monticello Minnesota Department of Commerce
ENCLOSURE 1 CORRECTIONS TO THE 2011 AREOR 1 Page to Follow
L-MT-16-035 Page 1 of 1 Broadleaf vegetation samples were not collected since 2011 due to unavailability; these samples were not included as missed samples, because they were considered to be above and beyond required samples. Since they were included in the Offsite Dose Calculation Manual (ODCM) ODCM-07.01 Table 1, they were required samples for Monticello Nuclear Generating Plant and should have been included as missed samples. The affected pages have been included in their entirety (Attachment 1) and should replace existing pages (5 and 17), ML12135A041.
The complete data tables were to be submitted as part of the report; however, this data was not included with the annual reports prior to 2013. Attachment 2 will be added to the back of the annual report as submitted; this will be an addition to the report and will not be replacing any pages in the report.
ENCLOSURE 1 ATTACHMENT 1 REPLACEMENT PAGES FOR THE 2011 AREOR 2 Pages to Follow
3.3 Program Execution The Program was executed as described in the preceding section with the following exceptions:
(1) Air Particulates / Air Iodine:
No air particulate / air iodine sample was available from location M-01 for the week ending June 29, 2011. There was no power, due to an open fuse.
No air particulate/air iodine sample was available from location M-03 for the week ending September 14, 2011. Run-time was significantly lower than expected.
(2) Thermoluminescent Dosimeters:
The TLD for location M-05S was missing in the field for the third quarter, 2011.
The TLD for location M-1B was missing in the field for the fourth quarter, 2011.
(3) Surface Water:
Surface water was not collected at location M-08 during the months of January and February, 2011, due to unsafe ice conditions. The June 14, 2011 sample for composite was damaged in transit.
(4) Well Water:
Well water was not collected at location MW-1 in January, 2011.
The January, 2011 sample collected from MW-12A sample was damaged in transit.
Well water from location MW-13A, October 17, 2011, was damaged in transit.
(5) Milk Milk was not available from locations M-16 and M-17 for January and February, 2011 collections. No milk was available from location M-17 after November 9, 2011.
(6) Invertebrates Bottom organisms were not collected in the Spring of 2011, due to high river levels.
Bottom organisms could not be collected from control location M-8 in the Fall of 2011, due to high river levels.
(7) Broad Leaf Vegetables Broad Leaf Vegetables were not collected in 2011 due to unavailability. The previous Critical Garden ceased to be used and attempts to obtain a sample from the new Critical Garden were unsuccessful.
Deviations from the program are summarized in Table 5.3.
3.4 Laboratory Procedures The iodine-131 analyses in milk and drinking water were made using a sensitive radiochemical procedure which involves separation of the iodine using an ion-exchange method and solvent extraction and subsequent beta counting.
Gamma-spectroscopic analyses are performed using high-purity germanium (HPGe) detectors.
Levels of iodine-131 in cabbage and natural vegetation and concentrations of airborne iodine-131 in charcoal samples were determined by gamma spectroscopy.
5
Table 5.3. MISSED COLLECTIONS AND ANALYSES All required samples were collected and analyzed as scheduled with the following exceptions:
Collection Reason for not Sample Analysis Location Date or conducting REMP Plans for Preventing Type Period as required Recurrence SW Gamma M-08 January Water frozen. None Required SW Gamma M-08 February Water frozen. None Required SW For composite M-08 6/14/2011 Sample damaged in transit. None Required WW Gamma, H-3 MW-1 1/17/2011 Well not sampled, frozen. None Required WW Gamma, H-3 MW-12A 1/17/2011 Container damaged in transit. None Required WW Gamma, H-3 MW-13A 10/17/2011 Container damaged in transit. None Required TLD Gamma M-5S 10/3/2011 TLD missing in field. Replaced, vandalism TLD Gamma M-1B 1/4/2012 TLD missing in field. Replaced, vandalism AP/AI Beta, I-131 M-1 6/29/2011 No power at sampler. Power restored by utility.
AP/AI Beta, I-131 M-3 9/14/2011 Elapsed time low. Replaced with spare, repaired affected pump.
MI Gamma, I-131 M-16, 17 1/31/2011 Milking discontinued until Spring. None Required MI Gamma, I-131 M-17 12/14/2011 Milking discontinued for the year. None Required BO Gamma M-8, M-9 Spring High water prevented sampling. None Required BO Gamma M-8 Fall High water prevented sampling. None Required Highest D/Q Samples became unavailable when Attempted to obtain a VE I-131 Garden and At Harvest previous Critical Garden ceased to be sample from new Control used. Critical Garden 17
ENCLOSURE 1 ATTACHMENT 2 ADDITIONAL PAGES FOR THE 2011 AREOR 40 Pages to Follow
~*' ATI E~vironmental, Inc.
Jl+"( 1"'\1 M1dwest laboratory 700 Landwehr Road
- Notthbrook. IL 60062-2310 phone (847) 564-0700
- fax (847) 564-4517 FINAL REPORT TO XCEL ENERGY CORPORATION RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM (REMP)
MONTICELLO NUCLEAR GENERATING PLANT DOCKET NO. 50-263 LICENSE NO. DPR-22 COMPLETE ANALYSES DATA TABLES January December, 2011 Prepared under contract by ENVIRONMENTAL, INC.
MIDWEST LABORATORY PROJECT NO. 8010 Reviewed and Approved
MNGP TABLE OF CONTENTS Section Page List of Tables.................................................................................................................. iii
1.0 INTRODUCTION
........................................................................................................... . iv 2.0 LISTING OF MISSED SAMPLES .................................................................................. . v 3.0 DATA TABLES ............................................................................................................... vi Appendices A lodine-131 Activity Detected in REMP Air Samples ..................................................... A-1 ii
MNGP LIST OF TABLES Ambient radiation as measured by thermoluminescent dosimeters (TLDs)................................. 1-1 2 Airborne particulates and iodine collected at Location M-1 (C), analysis for gross beta and iodine-131 ............................................................................................................... 2-1 3 Airborne particulates and iodine collected at Location M-2, analysis for gross beta and iodine-131...................................................................................................................... 3-1 4 Airborne particulates and iodine collected at Location M-3, analysis for gross beta and iodine-131 ...................................................................................................................... 4-1 5 Airborne particulates and iodine collected at Location M-4, analysis for gross beta and iodine-131 ...................................................................................................................... 5-1 6 Airborne particulates and iodine collected at Location M-5, analysis for gross beta and iodine-131 ...................................................................................................................... 6-1 7 Airborne particulates, analysis for gross beta, monthly averages................................................ 7-1 8 Airborne particulate samples, quarterly composites from each location, analysis for gamma-emitting 8-1 9 Milk, analysis for iodine-131 and gamma emitting isotopes......................................................... 9-1 9A Pasture Grass, vegetation, analysis for iodine-131 and gamma emitting isotopes...................... 9A-1 10 River water, upstream, M-8 (C) and M-9, analysis of monthly composites for gamma-emitting isotopes............................................................................................................ 10-1 11 Drinking water, City of Minneapolis, M-14, analysis of monthly composites for gross beta, iodine-131 and gamma-emitting isotopes............................................................. 11-1 12 River water and drinking water, analysis of quarterly composites for tritium................................ 12-1 13 Well water, analysis for tritium and gamma-emitting isotopes..................................................... 13-1 14 Fish, analysis of edible portions for gamma-emitting isotopes.................................................... 14-1 15 Algae or aquatic insects, analysis for gamma-emitting isotopes .... .. .... .... .... .. ...... .. .. .... .. .. .. .. .. .. .. . 15-1 16 Broad leaf vegetation, analysis for iodine-131 ............................................................................. 16-1 17 Shoreline sediments, analysis for gamma-emitting isotopes....................................................... 17-1 18 Storm run-off, analysis for tritium and gamma-emitting isotopes................................................. 18-1 iii
1.0 INTRODUCTION
The following constitutes the final 2011 report for the Environmental Radiological Monitoring Program conducted at the Monticello Nuclear Generating Plant in Monticello, Minnesota.
Results of completed analyses are presented in the attached tables.
All concentrations, except gross beta, are decay corrected to the time of collection.
All samples were collected within the scheduled period unless noted otherwise in the Listing of Missed Samples.
iv
2.0. LISTING of MISSED SAMPLES All required samples were collected and analyzed as scheduled with the following exceptions:
Collection Reason for not Sample Analysis Location Date or conducting REMP Plans for Preventing Type Period as required Recurrence SW Gamma M-08 January Water frozen. None Required SW Gamma M-08 February Water frozen. None Required SW For composite M-08 6/14/2011 Sample damaged in transit. None Required WW Gamma, H-3 MW-1 1/17/2011 Well not sampled, frozen. None Required WW Gamma, H-3 MW-12A 1/17/2011 Container damaged in transit. None Required WW Gamma, H-3 MW-13A 10/17/2011 Container damaged in transit. None Required TLD Gamma M-5S 10/3/2011 TLD missing in field. Replaced, vandalism TLD Gamma M-1B 1/4/2012 TLD missing in field. Replaced, vandalism AP/AI Beta, I-131 M-1 6/29/2011 No power at sampler. Power restored by utility.
AP/AI Beta, I-131 M-3 9/14/2011 Elapsed time low. Replaced with spare, repaired affected pump.
MI Gamma, I-131 M-16, 17 1/31/2011 Milking discontinued until Spring. None Required MI Gamma, I-131 M-17 12/14/2011 Milking discontinued for the year. None Required BO Gamma M-8, M-9 Spring High water prevented sampling. None Required BO Gamma M-8 Fall High water prevented sampling. None Required Highest D/Q Samples became unavailable when Attempted to obtain a VE I-131 Garden and At Harvest previous Critical Garden ceased to be sample from new Control used. Critical Garden v
MNGP 3.0 DATA TABLES vi
MONTICELLO Table 1. Ambient gamma radiation as measured by thermoluminescent dosimeters (TLD's).
Previous mRem/91 days Cumulative Annual Location 1st Qtr. 2nd Qtr. 3rd Qtr. 4th Qtr. Average Average Indicators (Inner Ring, General Area of Site Boundary)
M-01A 11.2 +/- 1.0 12.1 +/- 0.9 13.1 +/- 1.0 15.0 +/- 1.1 12.9 12.8 M-02A 13.5 +/- 1.1 13.7 +/- 0.6 15.2 +/- 0.9 17.5 +/- 1.0 15.0 14.7 M-03A 13.7 +/- 1.6 13.5 +/- 1.2 15.5 +/- 1.5 16.4 +/- 1.4 14.8 14.3 M-04A 11.9 +/- 1.0 13.9 +/- 0.9 14.1 +/- 1.1 17.3 +/- 1.0 14.3 14.3 M-05A 11.8 +/- 0.9 14.4 +/- 0.7 14.3 +/- 1.0 17.8 +/- 0.9 14.6 14.6 M-06A 12.7 +/- 0.9 14.7 +/- 0.8 15.6 +/- 0.7 18.0 +/- 0.9 15.3 15.1 M-07A 12.6 +/- 0.7 14.8 +/- 0.7 15.3 +/- 0.9 17.9 +/- 0.9 15.2 14.5 M-08A 14.2 +/- 1.2 14.6 +/- 0.6 14.4 +/- 1.0 16.4 +/- 1.0 14.9 15.0 M-09A 13.1 +/- 1.0 14.7 +/- 0.7 16.2 +/- 1.2 17.3 +/- 0.9 15.3 15.5 M-10A 12.4 +/- 0.9 14.4 +/- 0.8 15.3 +/- 1.1 17.2 +/- 0.9 14.8 15.1 M-11A 14.5 +/- 0.8 15.0 +/- 0.7 17.1 +/- 0.9 18.5 +/- 0.8 16.3 15.9 M-12A 12.8 +/- 0.9 15.2 +/- 0.6 15.5 +/- 0.8 18.4 +/- 0.9 15.5 15.3 M-13A 12.2 +/- 0.8 12.9 +/- 0.8 13.8 +/- 0.8 15.1 +/- 0.9 13.5 13.3 M-14A 12.6 +/- 0.6 13.9 +/- 0.7 15.4 +/- 0.9 16.7 +/- 0.7 14.7 15.0 Mean +/- s.d. 12.8 +/- 0.9 14.1 +/- 0.9 15.1 +/- 1.0 17.1 +/- 1.1 14.8 14.7 Indicators (Outer Ring, 4-5 Miles Distant)
M-01B 12.4 +/- 0.6 12.9 +/- 0.8 13.7 +/- 0.6 NDa 13.0 14.1 M-02B 13.5 +/- 0.7 13.8 +/- 1.1 14.7 +/- 0.9 16.0 +/- 0.7 14.5 14.4 M-03B 11.0 +/- 0.7 11.1 +/- 0.8 11.7 +/- 0.8 13.5 +/- 1.0 11.8 12.1 M-04B 11.6 +/- 0.6 13.3 +/- 0.6 13.5 +/- 0.6 15.5 +/- 0.8 13.5 13.6 M-05B 13.9 +/- 0.6 13.7 +/- 0.9 14.6 +/- 0.6 16.1 +/- 1.2 14.6 14.4 M-06B 12.6 +/- 0.9 14.3 +/- 0.7 14.9 +/- 1.0 17.0 +/- 0.9 14.7 14.6 M-07B 15.1 +/- 1.0 14.5 +/- 0.9 16.4 +/- 1.0 16.9 +/- 1.1 15.7 15.6 M-08B 13.4 +/- 0.9 13.9 +/- 0.7 13.6 +/- 1.4 16.3 +/- 1.0 14.3 13.9 M-09B 12.9 +/- 0.9 16.2 +/- 0.8 15.6 +/- 1.0 18.6 +/- 0.8 15.8 15.3 M-10B 12.9 +/- 0.7 15.1 +/- 0.9 16.5 +/- 0.8 17.3 +/- 1.1 15.5 15.3 M-11B 11.9 +/- 0.9 15.3 +/- 1.0 15.4 +/- 0.8 17.8 +/- 0.9 15.1 15.1 M-12B 12.1 +/- 0.8 15.3 +/- 0.8 14.7 +/- 1.0 17.7 +/- 0.8 15.0 14.5 M-13B 13.0 +/- 0.6 13.9 +/- 0.9 13.7 +/- 0.7 15.5 +/- 0.9 14.0 14.0 M-14B 12.4 +/- 0.9 15.1 +/- 0.7 14.0 +/- 1.2 17.3 +/- 0.8 14.7 14.6 M-15B 11.7 +/- 0.8 14.9 +/- 1.0 13.5 +/- 0.7 15.9 +/- 0.9 14.0 13.6 M-16B 11.7 +/- 0.6 13.0 +/- 1.0 12.3 +/- 0.6 14.5 +/- 1.0 12.9 13.5 Mean +/- s.d. 12.6 +/- 1.0 14.1 +/- 1.2 14.3 +/- 1.3 16.4 +/- 1.3 14.3 14.3 a
ND = No data; see Table 2.0, Listing of Missed Samples.
1-1
MONTICELLO Table 1. Ambient gamma radiation as measured by thermoluminescent dosimeters (TLD's),
(continued).
Previous mRem/91 days Cumulative Annual Location 1st Qtr. 2nd Qtr. 3rd Qtr. 4th Qtr. Average Average Control M-01C 12.6 +/- 0.9 14.1 +/- 1.0 16.5 +/- 1.5 16.0 +/- 1.2 14.8 14.5 M-02C 12.1 +/- 0.9 15.1 +/- 0.7 17.1 +/- 1.0 17.1 +/- 0.9 15.4 15.0 M-03C 13.6 +/- 0.6 15.8 +/- 0.8 18.3 +/- 0.7 18.2 +/- 1.1 16.5 16.1 M-04C 12.6 +/- 0.6 14.2 +/- 0.6 17.9 +/- 0.6 16.2 +/- 0.8 15.2 15.1 Mean +/- s.d. 12.7 +/- 0.6 14.8 +/- 0.8 17.5 +/- 0.8 16.9 +/- 1.0 15.5 15.2 Indicators (Special Interest Areas)
M-01S 10.8 +/- 0.9 13.0 +/- 0.7 11.2 +/- 0.9 15.6 +/- 0.7 12.7 12.2 M-02S 9.8 +/- 0.8 12.5 +/- 0.7 11.3 +/- 0.6 13.9 +/- 0.8 11.9 12.0 M-03S 12.2 +/- 0.9 14.5 +/- 0.9 13.6 +/- 0.9 16.5 +/- 1.2 14.2 14.3 M-04S 13.4 +/- 0.8 14.6 +/- 0.7 14.9 +/- 0.7 15.8 +/- 1.0 14.7 14.9 M-05S 13.1 +/- 0.9 14.3 +/- 0.8 NDa 16.0 +/- 1.1 14.5 14.5 M-06S 15.6 +/- 0.8 15.8 +/- 0.8 18.6 +/- 0.7 17.8 +/- 0.9 17.0 16.4 Mean +/- s.d. 12.5 +/- 2.1 14.1 +/- 1.2 13.9 +/- 3.1 15.9 +/- 1.3 14.1 14.0 Special TLDs M-I-01 62.9 +/- 1.5 46.5 +/- 1.6 88.6 +/- 2.4 72.9 +/- 2.7 67.7 89.1 M-I-02 52.8 +/- 2.2 38.3 +/- 0.8 74.9 +/- 3.4 61.7 +/- 1.1 56.9 73.3 M-I-03 34.9 +/- 0.9 28.2 +/- 1.6 46.5 +/- 1.5 40.0 +/- 1.3 37.4 49.8 M-I-04 29.8 +/- 1.2 25.6 +/- 1.3 39.4 +/- 1.5 35.4 +/- 2.0 32.6 40.1 M-I-05 37.8 +/- 2.4 39.7 +/- 2.0 52.3 +/- 1.9 49.5 +/- 1.8 44.8 53.8 M-I-06 22.6 +/- 1.0 23.7 +/- 0.8 29.5 +/- 1.2 28.5 +/- 1.5 26.1 30.4 M-I-07 27.2 +/- 1.4 26.6 +/- 1.3 32.6 +/- 1.7 33.0 +/- 1.5 29.9 35.6 M-I-08 25.3 +/- 1.5 21.9 +/- 1.5 32.1 +/- 2.0 28.0 +/- 1.2 26.8 33.4 M-I-09 44.9 +/- 1.3 49.0 +/- 2.7 56.4 +/- 2.8 56.2 +/- 3.0 51.6 66.4 M-I-10 41.9 +/- 0.9 29.6 +/- 1.5 55.5 +/- 2.0 41.4 +/- 1.7 42.1 53.5 M-I-11 14.0 +/- 1.0 14.1 +/- 0.6 17.5 +/- 0.7 16.4 +/- 0.7 15.5 16.2 M-I-12 12.0 +/- 0.6 14.4 +/- 0.7 16.5 +/- 0.6 16.9 +/- 0.8 15.0 15.1 M-I-13 13.9 +/- 1.6 14.4 +/- 0.8 18.8 +/- 2.1 16.8 +/- 0.9 16.0 16.2 Mean +/- s.d. 32.3 +/- 15.6 28.6 +/- 11.7 43.1 +/- 22.2 38.2 +/- 17.9 35.6 44.1 a
ND = No data; see Table 2.0, Listing of Missed Samples.
1-2
MONTICELLO Table 2. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 8 .
Location: M-1 (C) 3 Units: pCi/m Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (m") Gross Beta Collected (m") Gross Beta Required LLD 0.010 Required LLD 0.010 01-05-11 328 0.045 +/- 0.004 07-06-11 292 0.017 +/- 0.003 01-12-11 323 0.040 +/- 0.004 07-13-11 384 0.023 +/- 0.003 01-19-11 351 0.033 +/- 0.003 07-20-11 379 0.027 +/- 0.003 01-26-11 324 0.038 +/- 0.004 07-27-11 383 0.020 +/- 0.003 02-02-11 353 0.027 +/- 0.003 08-03-11 387 0.028 +/- 0.003 02-09-11 331 0.024 +/- 0.003 08-10-11 384 0.025 +/- 0.003 02-16-11 344 0.028 +/- 0.003 08-17-11 347 0.029 +/- 0.003 02-23-11 295 0.022 +/- 0.003 08-24-11 354 0.022 +/- 0.003 03-02-11 294 0.039 +/- 0.004 08-31-11 359 0.022 +/- 0.003 03-09-11 292 0.028 +/- 0.004 09-07-11 346 0.027 +/- 0.003 03-16-11 295 0.028 +/- 0.004 09-14-11 358 0.029 +/- 0.003 03-23-11 293 0.019 +/- 0.003 09-21-11 350 0.015 +/- 0.003 03-30-11 294 0.034 +/- 0.004 09-28-11 355 0.021 +/- 0.003 1st Quarter Mean +/- s.d. 0.031 +/- 0.008 3rd Quarter Mean +/- s.d. 0.023 +/- 0.005 04-06-11 294 0.034 +/- 0.004 10-05-11 349 0.026 +/- 0.003 04-13-11 295 0.022 +/- 0.003 10-12-11 354 0.040 +/- 0.004 04-20-11 299 0.033 +/- 0.004 10-19-11 354 0.022 +/- 0.003 04-27-11 293 0.022 +/- 0.003 10-26-11 354 0.023 +/- 0.003 11-02-11 381 0.022 +/- 0.003 05-04-11 292 0.016 +/- 0.003 05-11-11 293 0.017 +/- 0.003 11-09-11 356 0.029 +/- 0.003 05-18-11 352 0.007 +/- 0.002 11-16-11 351 0.037 +/- 0.003 05-25-11 384 0.013 +/- 0.002 11-23-11 356 0.032 +/- 0.003 06-01-11 382 0.016 +/- 0.002 11-30-11 322 0.056 +/- 0.004 06-08-11 383 0.021 +/- 0.003 12-07-11 354 0.036 +/- 0.003 06-14-11 336 0.009 +/- 0.002 12-14-11 355 0.062 +/- 0.004 06-22-11 359 0.018 +/- 0.003 12-21-11 323 0.041 +/- 0.004 06-29-11 NDC 12-28-11 318 0.024 +/- 0.003 2nd Quarter Mean +/- s.d. 0.019 +/- 0.008 4th Quarter Mean +/- s.d. 0.035 +/- 0.013 Cumulative Average 0.027 Previous Annual Average 0.026 a lodine-131 concentrations are< 0.03 pCi/m 3 unless otherwise noted.
b Air iodine activity detected; noted in Appendix A.
c ND = No data; see Table 2.0, Listing of Missed Samples.
2-1
MONTICELLO Table 3. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.
Location: M-2 3
Units: pCi/m Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (mj) Gross Beta Collected (mj) Gross Beta Required LLD 0.010 0.010 01-05-11 332 0.052 +/- 0.004 07-06-11 416 0.021 +/- 0.003 01-12-11 319 0.039 +/- 0.004 07-13-11 376 0.024 +/- 0.003 01-19-11 353 0.031 +/- 0.003 07-20-11 380 0.028 +/- 0.003 01-26-11 323 0.046 +/- 0.004 07-27-11 384 0.020 +/- 0.003 02-02-11 352 0.025 +/- 0.003 08-03-11 415 0.025 +/- 0.003 02-09-11 300 0.029 +/- 0.003 08-10-11 414 0.022 +/- 0.003 02-16-11 344 0.028 +/- 0.003 08-17-11 346 0.027 +/- 0.003 02-23-11 295 0.030 +/- 0.003 08-24-11 353 0.023 +/- 0.003 03-02-11 294 0.042 +/- 0.004 08-31-11 361 0.022 +/- 0.003 03-09-11 291 0.028 +/- 0.004 09-07-11 344 0.027 +/- 0.003 03-16-11 295 0.029 +/- 0.004 09-14-11 389 0.027 +/- 0.003 03-23-11 294 0.023 +/- 0.003 09-21-11 351 0.015 +/- 0.003 03-30-11 293 0.037 +/- 0.004 09-28-11 353 0.020 +/- 0.003 1st Quarter Mean +/- s.d. 0.034 +/- 0.009 3rd Quarter Mean +/- s.d. 0.023 +/- 0.004 04-06-11 294 0.035 +/- 0.004 10-05-11 349 0.028 +/- 0.003 04-13-11 295 0.028 +/- 0.003 10-12-11 354 0.045 +/- 0.004 04-20-11 299 0.036 +/- 0.004 10-19-11 353 0.019 +/- 0.003 04-27-11 293 0.021 +/- 0.003 10-26-11 355 0.025 +/- 0.003 11-02-11 381 0.027 +/- 0.003 05-04-11 292 0.018 +/- 0.003 05-11-11 293 0.020 +/- 0.003 11-09-11 355 0.028 +/- 0.003 05-18-11 295 0.013 +/- 0.003 11-16-11 351 0.037 +/- 0.003 05-25-11 383 0.012 +/- 0.002 11-23-11 356 0.030 +/- 0.003 06-01-11 381 0.018 +/- 0.003 11-30-11 323 0.053 +/- 0.004 06-08-11 384 0.024 +/- 0.003 12-07-11 353 0.033 +/- 0.003 06-14-11 336 0.012 +/- 0.002 12-14-11 356 0.066 +/- 0.004 06-22-11 437 0.017 +/-0.002 12-21-11 293 0.045 +/- 0.004 06-29-11 407 0.014 +/- 0.002 12-28-11 318 0.026 +/- 0.003 2nd Quarter Mean +/- s.d. 0.021 +/- 0.008 4th Quarter Mean +/- s.d. 0.035 +/- 0.013 Cumulative Average 0.028 Previous Annual Average 0.026 3
a lodine-131 concentrations are< 0.03 pCi/m unless otherwise noted.
b Air iodine activity detected; noted in Appendix A.
3-1
MONTICELLO Table 4. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 a Location: M-3 3
Units: pCi/m Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (m") Gross Beta Collected (m") Gross Beta Required LLD 0.010 0.010 01-05-11 332 0.049 +/- 0.004 07-06-11 357 0.024 +/- 0.003 01-12-11 319 0.042 +/- 0.004 07-13-11 347 0.025 +/- 0.003 01-19-11 353 0.038 +/- 0.003 07-20-11 350 0.028 +/- 0.003 01-26-11 323 0.045 +/- 0.004 07-27-11 355 0.019 +/- 0.003 02-02-11 352 0.027 +/- 0.003 08-03-11 355 0.029 +/- 0.003 02-09-11 300 0.033 +/- 0.004 08-10-11 355 0.023 +/- 0.003 02-16-11 344 0.031 +/- 0.003 08-17-11 347 0.025 +/- 0.003 02-23-11 295 0.025 +/- 0.003 08-24-11 353 0.023 +/- 0.003 03-02-11 294 0.039 +/- 0.004 08-31-11 331 0.024 +/- 0.003 03-09-11 291 0.028 +/- 0.003 09-07-11 344 0.027 +/- 0.003 03-16-11 295 0.033 +/- 0.004 09-14-11 NDC 03-23-11 294 0.023 +/- 0.003 09-21-11 321 0.017 +/- 0.003 03-30-11 293 0.039 +/- 0.004 09-28-11 323 0.022 +/- 0.003 1st Quarter Mean +/- s.d. 0.035 +/- 0.008 3rd Quarter Mean +/- s.d. 0.024 +/- 0.004 04-06-11 294 0.052 +/- 0.004 10-05-11 349 0.028 +/- 0.003 04-13-11 295 0.024 +/- 0.003 10-12-11 354 0.039 +/- 0.004 04-20-11 299 0.046 +/- 0.004 10-19-11 353 0.020 +/- 0.003 04-27-11 293 0.021 +/- 0.003 10-26-11 355 0.024 +/- 0.003 11-02-11 351 0.028 +/- 0.003 05-04-11 292 0.016 +/- 0.003 05-11-11 293 0.020 +/- 0.003 11-09-11 326 0.033 +/- 0.004 05-18-11 296 0.012 +/- 0.003 11-16-11 351 0.035 +/- 0.003 05-25-11 352 0.014 +/- 0.003 11-23-11 326 0.033 +/- 0.003 06-01-11 381 0.013 +/- 0.002 11-30-11 323 0.050 +/- 0.004 06-08-11 354 0.021 +/- 0.003 12-07-11 353 0.034 +/- 0.003 06-14-11 310 0.011 +/- 0.003 12-14-11 327 0.067 +/- 0.005 06-22-11 403 0.013 +/- 0.002 12-21-11 293 0.053 +/- 0.004 06-29-11 349 0.014 +/- 0.003 12-28-11 289 0.027 +/- 0.004 2nd Quarter Mean +/- s.d. 0.021 +/- 0.013 4th Quarter Mean +/- s.d. 0.036 +/- 0.013 Cumulative Average 0.029 Previous Annual Average 0.026 3
a lodine-131 concentrations are < 0.03 pCi/m unless otherwise noted.
b Air iodine activity detected; noted in Appendix A c ND =No data; see Table 2.0, Listing of Missed Samples.
4-1
MONTICELLO 8
Table 5. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131
- Location: M-4 3
Units: pCi/m Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (m3) Gross Beta Collected (m3) Gross Beta Required LLD 0.010 0.010 01-05-11 318 0.048 +/- 0.004 07-06-11 413 0.020 +/- 0.003 01-12-11 312 0.040 +/- 0.004 07-13-11 378 0.022 +/- 0.003 01-19-11 351 0.036 +/- 0.003 07-20-11 380 0.027 +/- 0.003 01-26-11 274 0.053 +/- 0.005 07-27-11 384 0.017 +/- 0.002 02-02-11 312 0.027 +/- 0.003 08-03-11 385 0.026 +/- 0.003 02-09-11 240 0.043 +/- 0.005 08-10-11 416 0.022 +/- 0.003 02-16-11 286 0.027 +/- 0.004 08-17-11 346 0.026 +/- 0.003 02-23-11 196 0.034 +/- 0.005 08-24-11 353 0.022 +/- 0.003 03-02-11 196 0.053 +/- 0.006 08-31-11 332 0.023 +/- 0.003 03-09-11 194 0.039 +/- 0.005 09-07-11 318 0.029 +/- 0.003 03-16-11 196 0.034 +/- 0.005 09-14-11 331 0.039 +/- 0.004 03-23-11 196 0.027 +/- 0.005 09-21-11 323 0.017 +/- 0.003 03-30-11 195 0.044 +/- 0.006 09-28-11 326 0.021 +/- 0.003 1st Quarter Mean +/- s.d. 0.039 +/- 0.009 3rd Quarter Mean +/- s.d. 0.024 +/- 0.006 04-06-11 195 0.047 +/- 0.005 10-05-11 349 0.028 +/- 0.003 04-13-11 196 0.029 +/- 0.005 10-12-11 354 0.041 +/- 0.004 04-20-11 199 0.041 +/- 0.005 10-19-11 353 0.021 +/- 0.003 04-27-11 195 0.024 +/- 0.004 10-26-11 354 0.025 +/- 0.003 11-02-11 351 0.028 +/- 0.003 05-04-11 194 0.020 +/- 0.004 05-11-11 195 0.018 +/- 0.004 11-09-11 328 0.030 +/- 0.003 05-18-11 275 0.010 +/- 0.003 11-16-11 351 0.036 +/- 0.003 05-25-11 382 0.010 +/- 0.002 11-23-11 328 0.031 +/- 0.003 06-01-11 382 0.013 +/- 0.002 11-30-11 325 0.051 +/- 0.004 06-08-11 384 0.022 +/- 0.003 12-07-11 353 0.036 +/- 0.003 06-14-11 362 0.011 +/- 0.002 12-14-11 328 0.070 +/- 0.005 06-22-11 437 0.011 +/- 0.002 12-21-11 297 0.043 +/- 0.004 06-29-11 378 0.015 +/- 0.002 12-28-11 294 0.025 +/- 0.003 2nd Quarter Mean +/- s.d. 0.021 +/- 0.012 4th Quarter Mean +/- s.d. 0.036 +/- 0.013 Cumulative Average 0.030 Previous Annual Average 0.027 3
a lodine-131 concentrations are< 0.03 pCi/m unless otherwise noted.
b Air iodine activity detected; noted in Appendix A.
5-1
MONTICELLO Table 6. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 a.
Location: M-5 3
Units: pCi/m Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (m") Gross Beta Collected (m") Gross Beta Required LLD 0.010 0.010 01-05-11 329 0.045 +/- 0.004 07-06-11 381 0.020 +/- 0.003 01-12-11 323 0.043 +/- 0.004 07-13-11 349 0.024 +/- 0.003 01-19-11 352 0.034 +/- 0.003 07-20-11 350 0.028 +/- 0.003 01-26-11 324 0.041 +/- 0.004 07-27-11 354 0.019 +/- 0.003 02-02-11 352 0.027 +/- 0.003 08-03-11 356 0.025 +/- 0.003 02-09-11 300 0.031 +/- 0.004 08-10-11 354 0.023 +/- 0.003 02-16-11 344 0.025 +/- 0.003 08-17-11 372 0.025 +/- 0.003 02-23-11 295 0.027 +/- 0.003 08-24-11 380 0.020 +/- 0.003 03-02-11 294 0.038 +/- 0.004 08-31-11 388 0.021 +/- 0.003 03-09-11 291 0.028 +/- 0.003 09-07-11 371 0.026 +/- 0.003 03-16-11 295 0.032 +/- 0.004 09-14-11 387 0.033 +/- 0.003 b
03-23-11 293 0.023 +/- 0.003 09-21-11 350 0.016 +/- 0.003 03-30-11 293 0.041 +/- 0.004 09-28-11 354 0.017 +/- 0.003 1st Quarter Mean +/- s.d. 0.033 +/- 0.007 3rd Quarter Mean +/- s.d. 0.023 +/- 0.005 04-06-11 294 0.036 +/- 0.004 10-05-11 376 0.026 +/- 0.003 04-13-11 295 0.024 +/- 0.003 10-12-11 354 0.039 +/- 0.004 04-20-11 299 0.035 +/- 0.004 10-19-11 353 0.018 +/- 0.003 04-27-11 293 0.019 +/- 0.003 10-26-11 354 0.025 +/- 0.003 11-02-11 378 0.027 +/- 0.003 05-04-11 292 0.017 +/- 0.003 05-11-11 293 0.019 +/- 0.003 11-09-11 383 0.028 +/- 0.003 05-18-11 353 0.010 +/- 0.002 11-16-11 351 0.032 +/- 0.003 05-25-11 382 0.012 +/- 0.002 11-23-11 356 0.027 +/- 0.003 06-01-11 382 0.015 +/- 0.002 11-30-11 352 0.046 +/- 0.004 06-08-11 354 0.026 +/- 0.003 12-07-11 354 0.037 +/- 0.004 06-14-11 322 0.011 +/- 0.002 12-14-11 296 0.068 +/- 0.005 06-22-11 402 0.015 +/- 0.002 12-21-11 293 0.048 +/- 0.004 06-29-11 349 0.012 +/- 0.002 12-28-11 289 0.022 +/- 0.003 2nd Quarter Mean +/- s.d. 0.019 +/- 0.009 4th Quarter Mean +/- s.d. 0.034 +/- 0.014 Cumulative Average 0.027 Previous Annual Average 0.025 3
a lodine-131 concentrations are< 0.03 pCi/m unless otherwise noted.
b Air iodine activity detected; noted in Appendix A.
6-1
MONTICELLO Table 7. Airborne particulate data, gross beta analyses, monthly averages, minima and maxima.
January April Location Average Minima Maxima Location Average Minima Maxima Control 0.037 0.027 0.045 Control 0.028 0.022 0.034 M-1 0.037 0.027 0.045 M-1 0.028 0.022 0.034 Indicators 0.040 0.025 0.053 Indicators 0.032 0.019 0.052 M-2 0.039 0.025 0.052 M-2 0.030 0.021 0.036 M-3 0.040 0.027 0.049 M-3 0.036 0.021 0.052 M-4 0.041 0.027 0.053 M-4 0.035 0.024 0.047 M-5 0.038 0.027 0.045 M-5 0.028 0.019 0.036 February May Location Average Minima Maxima Location Average Minima Maxima Control 0.028 0.022 0.039 Control 0.014 0.007 0.017 M-1 0.028 0.022 0.039 M-1 0.014 0.007 0.017 Indicators 0.033 0.025 0.053 Indicators 0.015 0.010 0.020 M-2 0.032 0.028 0.042 M-2 0.016 0.012 0.020 M-3 0.032 0.025 0.039 M-3 0.015 0.012 0.020 M-4 0.039 0.027 0.053 M-4 0.015 0.010 0.020 M-5 0.030 0.025 0.038 M-5 0.015 0.010 0.019 March June Location Average Minima Maxima Location Average Minima Maxima Control 0.027 0.019 0.034 Control 0.016 0.009 0.021 M-1 0.027 0.019 0.034 M-1 0.016 0.009 0.021 Indicators 0.032 0.023 0.044 Indicators 0.016 0.011 0.026 M-2 0.029 0.023 0.037 M-2 0.017 0.012 0.024 M-3 0.031 0.023 0.039 M-3 0.015 0.011 0.021 M-4 0.036 0.027 0.044 M-4 0.015 0.011 0.022 M-5 0.031 0.023 0.041 M-5 0.016 0.011 0.026 Note: unless otherwise specified, samples collected on the first, second or third day of the month are grouped with data of the previous month.
7-1
MONTICELLO Table 7. Airborne particulate data, gross beta analyses, monthly averages, minima and maxima.
July October Location Average Minima Maxima Location Average Minima Maxima Control 0.023 0.017 0.028 Control 0.028 0.022 0.040 M-1 0.023 0.017 0.028 M-1 0.028 0.022 0.040 Indicators 0.024 0.017 0.029 Indicators 0.028 0.018 0.045 M-2 0.024 0.020 0.028 M-2 0.029 0.019 0.045 M-3 0.025 0.019 0.029 M-3 0.028 0.020 0.039 M-4 0.022 0.017 0.027 M-4 0.029 0.021 0.041 M-5 0.023 0.019 0.028 M-5 0.027 0.018 0.039 August November Location Average Minima Maxima Location Average Minima Maxima Control Control 0.033 0.029 0.037 M-1 0.025 0.022 0.029 M-1 0.033 0.029 0.037 Indicators 0.023 0.020 0.027 Indicators 0.032 0.027 0.037 M-2 0.024 0.022 0.027 M-2 0.032 0.028 0.037 M-3 0.024 0.023 0.025 M-3 0.034 0.033 0.035 M-4 0.023 0.022 0.026 M-4 0.032 0.030 0.036 M-5 0.022 0.020 0.025 M-5 0.029 0.027 0.032 September December Location Average Minima Maxima Location Average Minima Maxima Control Control 0.041 0.024 0.062 M-1 0.023 0.015 0.029 M-1 0.041 0.024 0.062 Indicators 0.023 0.015 0.039 Indicators 0.044 0.022 0.070 M-2 0.022 0.015 0.027 M-2 0.043 0.026 0.066 M-3 0.022 0.017 0.027 M-3 0.045 0.027 0.067 M-4 0.027 0.017 0.039 M-4 0.044 0.025 0.070 M-5 0.023 0.016 0.033 M-5 0.044 0.022 0.068 Note: unless otherwise specified, samples collected on the first, second or third day of the month are grouped with data of the previous month.
7-2
MONTICELLO Table 8. Airborne particulates, quarterly composites from each location, analysis for gamma-emitting isotopes.
3 Activity (pCi/m )
Cumulative Previous 1st Qtr. 2nd Qtr. 3rd Otr. 4th Otr. Average Average M-1 (C)
Lab Code MAP- 2234 MAP- 4840 MAP- 7040 MAP- 9202 3
Volume(m ) 4116 3963 4677 4526 Be-7 0.065 +/- 0.016 0.078 +/- 0.014 0.074 +/- 0.012 0.056 +/- 0.009 0.065 0.077 Mn-54 < 0.0006 < 0.0005 < 0.0007 < 0.0003 <0.0007 <0.0006 Co-58 < 0.0003 < 0.0005 < 0.0008 < 0.0005 <0.0008 <0.0008 Co-60 < 0.0008 < 0.0006 < 0.0007 < 0.0003 <0.0008 <0.0006 Zn-65 < 0.0018 < 0.0007 < 0.0004 < 0.0004 <0.0018 <0.0008 Zr-Nb-95 < 0.0011 < 0.0007 < 0.0010 < 0.0004 <0.0011 <0.0006 Ru-103 < 0.0006 < 0.0007 < 0.0008 < 0.0007 <0.0008 <0.0007 Ru-106 < 0.0049 < 0.0050 < 0.0070 < 0.0049 <0.0070 <0.0049 Cs-134 < 0.0006 < 0.0008 < 0.0008 < 0.0004 <0.0008 <0.0005 Cs-137 < 0.0005 < 0.0008 < 0.0007 < 0.0002 <0.0008 <0.0004 Ba-La-140 < 0.0024 < 0.0021 < 0.0018 < 0.0013 <0.0024 <0.0017 Ce-141 < 0.0019 < 0.0015 < 0.0013 < 0.0008 <0.0019 <0.0013 Ce-144 < 0.0050 < 0.0039 < 0.0042 < 0.0022 <0.0050 <0.0035 M-2 Lab Code MAP- 2235 MAP- 4841 MAP- 7041 MAP- 9203 3
Volurne(m ) 4086 4388 4880 4497 Be-7 0.067 +/- 0.015 0.085 +/- 0.014 0.070 +/- 0.012 0.053 +/- 0.016 0.063 0.073 Mn-54 < 0.0009 < 0.0007 < 0.0005 < 0.0005 <0.0009 <0.0005 Co-58 < 0.0007 < 0.0005 < 0.0005 < 0.0006 <0.0007 <0.0005 Co-60 < 0.0007 < 0.0005 < 0.0004 < 0.0008 <0.0007 <0.0006 Zn-65 < 0.0007 < 0.0006 < 0.0005 < 0.0006 <0.0007 <0.0006 Zr-Nb-95 < 0.0008 < 0.0008 < 0.0005 < 0.0010 <0.0008 <0.0006 Ru-103 < 0.0011 < 0.0011 < 0.0006 < 0.0008 <0.0011 <0.0007 Ru-106 < 0.0043 < 0.0035 < 0.0026 < 0.0064 <0.0043 <0.0040 Cs-134 < 0.0005 < 0.0007 < 0.0006 < 0.0003 <0.0007 <0.0005 Cs-137 < 0.0003 < 0.0007 < 0.0004 < 0.0005 <0.0007 <0.0005 Ba-La-140 < 0.0028 < 0.0020 < 0.0015 < 0.0026 <0.0028 <0.0016 Ce-141 < 0.0008 < 0.0018 < 0.0009 < 0.0015 <0.0018 <0.0013 Ce-144 < 0.0038 < 0.0039 < 0.0021 < 0.0024 <0.0039 <0.0034 8-1
MONTICELLO Table 8. Airborne particulates, quarterly composites from each location, analysis for gamma-emitting isotopes.
Activity (pCi/m 3 )
Cumulative Previous 1st Otr. 2nd Otr. 3rd Otr. 4th Qtr. Average Average M-3 Lab Code MAP- 2236 MAP- 4842 MAP- 7042 MAP- 9204 3
Volume(m ) 4086 4211 4137 4349 Be-7 0.068 +/- 0.014 0.093 +/- 0.014 0.081 +/- 0.014 0.061 +/- 0.015 0.070 0.075 Mn-54 < 0.0008 < 0.0006 < 0.0003 < 0.0007 <0.0008 <0.0006 Co-58 < 0.0004 < 0.0004 < 0.0006 < 0.0009 <0.0006 <0.0007 Co-60 < 0.0005 < 0.0004 < 0.0006 < 0.0007 <0.0006 <0.0009 Zn-65 < 0.0007 < 0.0014 < 0.0008 < 0.0008 <0.0014 <0.0008 Zr-Nb-95 < 0.0008 < 0.0011 < 0.0008 < 0.0010 <0.0011 <0.001 0 Ru-103 < 0.0010 < 0.0008 < 0.0007 < 0.0009 <0.001 0 <0.0014 Ru-106 < 0.0033 < 0.0064 < 0.0075 < 0.0074 <0.0075 <0.0058 a
Cs-134 < 0.0005 0.0013 +/- 0.0005 < 0.0006 < 0.0006 0.0013 <0.0008 a
Cs-137 < 0.0005 0.0014 +/- 0.0008 < 0.0005 < 0.0007 0.0014 <0.0009 Ba-La-140 < 0.0028 < 0.0015 < 0.0020 < 0.0024 <0.0028 <0.0016 Ce-141 < 0.0011 < 0.0010 < 0.0014 < 0.0020 <0.0014 <0.0019 Ce-144 < 0.0050 < 0.0041 < 0.0029 < 0.0037 <0.0050 <0.0054 M-4 Lab Code MAP- 2237 MAP- 4843 MAP- 7043 MAP- 9205 3
Volume(m ) 3264 3774 4684 4365 Be-7 0.076 +/- 0.016 0.080 +/- 0.015 0.074 +/- 0.011 0.057 +/- 0.015 0.069 0.084 Mn-54 < 0.0007 < 0.0010 < 0.0006 < 0.0004 <0.0010 <0.0006 Co-58 < 0.0010 < 0.0012 < 0.0005 < 0.0006 <0.0012 <0.0007 Co-60 < 0.0010 < 0.0006 < 0.0002 < 0.0006 <0.0010 <0.0009 Zn-65 < 0.0013 < 0.0017 < 0.0004 < 0.0006 <0.0017 <0.0011 Zr-Nb-95 < 0.0009 < 0.0012 < 0.0008 < 0.0006 <0.0012 <0.0012 Ru-103 < 0.0013 < 0.0011 < 0.0007 < 0.0008 <0.0013 <0.0009 Ru-106 < 0.0089 < 0.0098 < 0.0050 < 0.0055 <0.0098 <0.0065 Cs-134 < 0.0011 < 0.0008 < 0.0005 < 0.0006 <0.0011 <0.0006 Cs-137 < 0.0008 < 0.0010 < 0.0004 < 0.0004 <0.0010 <0.001 0 Ba-La-140 < 0.0022 < 0.0035 < 0.0010 < 0.0025 <0.0035 <0.0025 Ce-141 < 0.0023 < 0.0015 < 0.0009 < 0.0012 <0.0023 <0.0020 Ce-144 < 0.0063 < 0.0049 < 0.0021 < 0.0024 <0.0063 <0.0056 a Low levels of Cs-134 and 137 found in air particulates throughout the U.S. due to the Fukushima Daiichi event.
8-2
MONTICELLO Table 8. Airborne particulates, quarterly composites from each location, analysis for gamma-emitting isotopes.
Activity (pCi/m 3 )
Cumulative Previous 1st Qtr. 2nd Otr. 3rd Qtr. 4th Qtr. Average Average M-5 Lab Code MAP- 2238 MAP- 4844 MAP- 7044 MAP- 9206 3
Volume(m ) 4085 4311 4744 4488 Be-7 0.064 +/- 0.012 0.078 +/- 0.015 0.067 +/- 0.012 0.061 +/- 0.013 0.064 0.070 Mn-54 < 0.0009 < 0.0004 < 0.0006 < 0.0006 <0.0009 <0.0006 Co-58 < 0.0006 < 0.0009 < 0.0007 < 0.0006 <0.0009 <0.0008 Co-60 < 0.0007 < 0.0008 < 0.0006 < 0.0005 <0.0008 <0.0007 Zn-65 < 0.0010 < 0.0006 < 0.0007 < 0.0005 <0.001 0 <0.0009 Zr-Nb-95 < 0.0010 < 0.0014 < 0.0008 < 0.0010 <0.0014 <0.0010 Ru-103 < 0.0007 < 0.0009 < 0.0011 < 0.0008 <0.0011 <0.0008 Ru-106 < 0.0079 < 0.0043 < 0.0058 < 0.0052 <0.0079 <0.0072 Cs-134 < 0.0004 < 0.0008 < 0.0005 < 0.0004 <0.0008 <0.0005 Cs-137 < 0.0007 < 0.0006 < 0.0009 < 0.0005 <0.0009 <0.0007 Ba-La-140 < 0.0034 < 0.0021 < 0.0019 < 0.0027 <0.0034 <0.0019 Ce-141 < 0.0014 < 0.0017 < 0.0014 < 0.0015 <0.0017 <0.0013 Ce-144 < 0.0050 < 0.0026 < 0.0033 < 0.0035 <0.0050 <0.0045 8-3
MONTICELLO Table 9. Milk, analysis for iodine-131 and gamma-emitting isotopes.
Collection: Monthly - November through April.
Biweekly- May through October.
Date Lab Concentration (pCi/L)
Location Collected Code 1-131 K-40 Cs-134 Cs-137 Ba-La-140 8
Kitzman 01-31-11 NS 0
M-16 03-30-11 MMI -1538 1.5+/-0.2 1655 +/- 123 <5 <5 <5 b
04-27-11 MMI -2523 1.3 +/- 0.2 1792 +/- 126 <5 <5 <5 0
05-11-11 MMI -2824 1.1+/-0.2 1868 +/- 126 <5 <5 <5 05-25-11 MMI -3214 < 0.5 1826 +/- 127 <5 <5 <5 06-08-11 MMI -3660 < 0.5 1837 +/- 99 <5 <5 <5 06-22-11 MMI -3921 < 0.5 1717 +/- 127 <5 <5 <5 07-06-11 MMI -4307 < 0.5 1754 +/- 119 <5 <5 <5 07-20-11 MMI -4710 < 0.5 1889 +/- 129 <5 <5 <5 08-03-11 MMI -5282 < 0.5 1869 +/- 112 <5 <5 <5 08-17-11 MMI -5605 < 0.5 1790 +/- 126 <5 <5 <5 08-31-11 MMI -5898 < 0.5 1869 +/- 103 <5 <5 <5 09-14-11 MMI -6242 < 0.5 1856 +/- 125 <5 <5 <5 09-28-11 MMI -6471 < 0.5 1835 +/- 119 <5 <5 <5 10-12-11 MMI -6891 < 0.5 1867 +/- 99 <5 <5 <5 10-26-11 MMI -7455 < 0.5 1922 +/- 117 <5 <5 <5 11-09-11 MMI -7865 < 0.5 1743 +/- 99 <5 <5 <5 12-14-11 MMI -8668 < 0.5 1815 +/- 125 <5 <5 <5 Cumulative Average 1.4 1818 <5 <5 <5 Previous Annual Average < 0.5 1762 <5 <5 <5 8
Greniger (C) 01-31-11 NS b
M-17C 03-30-11 MMI -1539 1.5+/-0.2 1756 +/- 131 <5 <5 <5 04-27-11 MMI -2524 < 0.5 1629 +/- 115 <5 <5 <5 05-13-11 MMI -3011 < 0.5 1777 +/- 120 <5 <5 <5 05-25-11 MMI -3215 < 0.5 1717 +/- 129 <5 <5 <5 06-10-11 MMI -3728 < 0.5 1920 +/- 107 <5 <5 <5 06-22-11 MMI -3922 < 0.5 1878 +/- 129 <5 <5 <5 07-06-11 MMI -4308 < 0.5 1805 +/- 122 <5 <5 <5 07-20-11 MMI -4711 < 0.5 1906 +/- 130 <5 <5 <5 08-03-11 MMI -5283 < 0.5 1794 +/- 114 <5 <5 <5 08-17-11 MMI -5606 < 0.5 1793 +/- 137 <5 <5 <5 08-31-11 MMI -5899 < 0.5 1781 +/- 104 <5 <5 <5 09-14-11 MMI -6243 < 0.5 1725+/-121 <5 <5 <5 09-28-11 MMI -6472 < 0.5 1994 +/- 121 <5 <5 <5 10-12-11 MMI -6892 < 0.5 1847 +/- 88 <5 <5 <5 10-26-11 MMI -7456 < 0.5 1920 +/- 121 <5 <5 <5 11-09-11 MMI -7866 < 0.5 1896 +/- 103 <5 <5 <5 8
12-14-11 NS Cumulative Average 1.5 1821 <5 <5 <5 Previous Annual Average < 0.5 1788 <5 <5 <5 a NS =No sample; see Table 2.0, Listing of Missed Samples.
b The low levels of 1-131 detected are attributed to the Fukushima Daiichi event.
9-1
Table 9A. Pasture grass, vegetation, analysis for gamma-emitting isotopes.
Collection: 3x per year Previous Sample Description and Concentration (pCi/g wet) Annual Annual Average Average Location: M-41 (Training Center)
Date Collected 08-31-11 09-21-11 Lab Code MVE- 5900 MVE- 6427 Mn-54 < 0.007 < 0.008 < 0.008 < 0.015 Fe-59 < 0.026 < 0.013 < 0.026 < 0.040 Co-58 < 0.012 < 0.008 < 0.012 < 0.013 Co-60 < 0.006 < 0.008 < 0.008 < 0.013 Zn-65 < 0.024 < 0.012 < 0.024 < 0.036 Nb-95 < 0.013 < 0.005 < 0.013 < 0.018 1-131 < 0.020 < 0.012 < 0.020 < 0.018 Cs-134 < 0.009 < 0.007 < 0.009 < 0.014 Cs-137 < 0.012 < 0.010 < 0.012 < 0.017 Location: M-42 (Biology Station Road)
Date Collected 08-31-11 09-21-11 Lab Code MVE- 5901 MVE- 6428 Mn-54 < 0.007 < 0.010 < 0.010 < 0.017 Fe-59 < 0.027 < 0.015 < 0.027 < 0.038 Co-58 < 0.006 < 0.010 < 0.010 < 0.015 Co-60 < 0.008 < 0.009 < 0.009 < 0.019 Zn-65 < 0.016 < 0.035 < 0.035 < 0.026 Nb-95 < 0.012 < 0.010 < 0.012 < 0.015 1-131 < 0.020 < 0.017 < 0.020 < 0.022 Cs-134 < 0.007 < 0.013 < 0.013 < 0.014 Cs-137 < 0.007 < 0.014 < 0.014 < 0.020 Location: M-43 (lmholte Farm, Control)
Date Collected 08-31-11 09-21-11 Lab Code MVE- 5902 MVE- 6429 Mn-54 < 0.011 < 0.010 < 0.011 < 0.016 Fe-59 < 0.022 < 0.027 < 0.027 < 0.038 Co-58 < 0.009 < 0.009 < 0.009 < 0.012 Co-60 < 0.006 < 0.009 < 0.009 < 0.011 Zn-65 < 0.017 < 0.017 < 0.017 < 0.020 Nb-95 < 0.007 < 0.011 < 0.011 < 0.017 1-131 < 0.020 < 0.021 < 0.021 < 0.027 Cs-134 < 0.010 < 0.007 < 0.010 < 0.013 Cs-137 < 0.009 < 0.012 < 0.012 < 0.013 9A-1
MONTICELLO Table 10. River water, analysis of monthly composites for gamma-emitting isotopes.
Location: M-8 (C)
Collection: Weekly Sample Description and Concentration (pCi/L)
Period Collected January February March April May 8 8 Lab Code NS NS MSW-2118 MSW-3004 MSW-3675 Mn-54 < 10 < 10 < 10 Fe-59 < 30 < 30 < 30 Co-58 < 10 < 10 < 10 Co-60 < 10 < 10 < 10 Zn-65 < 30 < 30 < 30 Zr-Nb-95 < 15 < 15 < 15 Cs-134 < 10 < 10 < 10 Cs-137 < 10 < 10 < 10 Ba-La-140 < 15 < 15 < 15 Ce-144 < 15 < 15 < 20 Period Collected June July August September October Lab Code MSW-4721b MSW-5357 MSW-6273 MSW-6830 MSW-8088 Mn-54 < 10 < 10 < 10 < 10 < 10 Fe-59 < 30 < 30 < 30 < 30 < 30 Co-58 < 10 < 10 < 10 < 10 < 10 Co-60 < 10 < 10 < 10 < 10 < 10 Zn-65 < 30 < 30 < 30 < 30 < 30 Zr-Nb-95 < 15 < 15 < 15 < 15 < 15 Cs-134 < 10 <10 < 10 < 10 < 10 Cs-137 < 10 < 10 < 10 < 10 < 10 Ba-La-140 < 15 < 15 < 15 < 15 < 15 Ce-144 < 14 < 15 <16 < 16 < 15 Previous Period Collected November December Cumulative Annual Lab Code MSW-8649 MSW-9238 Average Average Mn-54 < 10 < 10 < 10 < 10 Fe-59 < 30 < 30 < 30 < 30 Co-58 < 10 < 10 < 10 < 10 Co-60 < 10 < 10 < 10 < 10 Zn-65 < 30 < 30 < 30 < 30 Zr-Nb-95 < 15 < 15 < 15 < 15 Cs-134 < 10 < 10 < 10 < 10 Cs-137 < 10 < 10 < 10 < 10 Ba-La-140 < 15 < 15 < 15 < 15 Ce-144 < 21 < 26 < 26 < 28 aND= No data; see Table 2.0, Listing of Missed Samples.
b Composite of three samples for month; see Table 2.0, Listing of Missed Samples.
10-1
MONTICELLO Table 10. River water, analysis of monthly composites for gamma-emitting isotopes.
Location: M-9 Collection: Weekly Sample Description and Concentration (pCi/L)
Period Collected January February March April May Lab Code MSW-528 MSW-1009 MSW-2119 MSW-3005 MSW-3676 Mn-54 < 10 < 10 < 10 < 10 < 10 Fe-59 < 30 < 30 < 30 < 30 < 30 Co-58 < 10 < 10 < 10 < 10 < 10 Co-60 < 10 < 10 < 10 < 10 < 10 Zn-65 < 30 < 30 < 30 < 30 < 30 Zr-Nb-95 < 15 < 15 < 15 < 15 < 15 Cs-134 < 10 < 10 < 10 < 10 < 10 Cs-137 < 10 < 10 < 10 < 10 < 10 Ba-La-140 < 15 < 15 < 15 < 15 < 15 Ce-144 < 25 < 17 <16 < 11 < 17 Period Collected June July August September October Lab Code MSW-4722 MSW-5358 MSW-6274 MSW-6831 MSW-8089 Mn-54 < 10 < 10 < 10 < 10 < 10 Fe-59 < 30 < 30 < 30 < 30 < 30 Co-58 < 10 < 10 < 10 < 10 < 10 Co-60 < 10 < 10 < 10 < 10 < 10 Zn-65 < 30 < 30 < 30 < 30 < 30 Zr-Nb-95 < 15 < 15 < 15 < 15 < 15 Cs-134 < 10 < 10 < 10 < 10 < 10 Cs-137 < 10 < 10 < 10 < 10 < 10 Ba-La-140 < 15 < 15 < 15 < 15 < 15 Ce-144 < 16 < 20 < 16 < 22 < 34 Previous Period Collected November December Cumulative Annual Lab Code MSW-8650 MSW-9240 Average Average Mn-54 < 10 < 10 < 10 < 10 Fe-59 < 30 < 30 < 30 < 30 Co-58 < 10 < 10 < 10 < 10 Co-60 < 10 < 10 < 10 < 10 Zn-65 < 30 < 30 < 30 < 30 Zr-Nb-95 < 15 < 15 < 15 < 15 Cs-134 < 10 < 10 < 10 < 10 Cs-137 < 10 < 10 < 10 < 10 Ba-La-140 < 15 < 15 < 15 < 15 Ce-144 < 43 < 22 < 43 < 40 10-2
MONTICELLO Table11. Drinking water, City of Minneapolis, M-14, analysis of monthly composites for gross beta, iodine-131, and gamma-emitting isotopes.
Collection: Weekly Sample Description and Concentration (pCi/L)
Period Collected January February March April May Lab Code MDW-497 MDW-951 MDW-1597 MDW-2624 MDW-3587 Gross beta 1.7+/-0.4 2.6 +/- 0.8 2.7 +/-1.3 3.0 +/- 1.6 2.4 +/- 1.0 1-131 < 1.0 < 1.0 < 1.0 < 1.0 < 1.0 Mn-54 < 10 < 10 < 10 < 10 < 10 Fe-59 < 30 < 30 < 30 < 30 < 30 Co-58 < 10 < 10 < 10 < 10 < 10 Co-60 < 10 < 10 < 10 < 10 < 10 Zn-65 < 30 < 30 < 30 < 30 < 30 Zr-Nb-95 < 15 < 15 < 15 < 15 < 15 Cs-134 < 10 < 10 < 10 < 10 < 10 Cs-137 < 10 < 10 < 10 < 10 < 10 Ba-La-140 < 15 < 15 < 15 < 15 < 15 Ce-144 < 19 < 19 < 26 < 18 <19 Period Collected June July August September October Lab Code MDW-4270 MDW-5240 MDW-5943 MDW-6606 MDW-7781 Gross beta 2.2 +/- 0.7 1.7 +/-0.9 2.2 +/- 1.0 1.4 +/-0.6 2.7 +/- 1.3 1-131 < 1.0 < 1.0 < 1.0 < 1.0 < 1.0 Mn-54 < 10 < 10 < 10 < 10 < 10 Fe-59 < 30 < 30 < 30 < 30 < 30 Co-58 < 10 < 10 <10 < 10 < 10 Co-60 < 10 < 10 <10 < 10 < 10 Zn-65 < 30 < 30 < 30 < 30 < 30 Zr-Nb-95 < 15 < 15 < 15 < 15 < 15 Cs-134 < 10 < 10 < 10 < 10 < 10 Cs-137 < 10 < 10 < 10 < 10 < 10 Ba-La-140 < 15 < 15 < 15 < 15 < 15 Ce-144 < 21 < 21 < 22 < 19 < 23 Period Collected November December Cumulative Previous Lab Code MDW-8464 MDW-9116 Average Average Gross beta 3.0 +/- 1.1 1.0 +/- 0.5 2.2 2.9 1-131 < 1.0 < 1.0 < 1.0 < 1.0 Mn-54 < 10 < 10 < 10 < 10 Fe-59 < 30 < 30 < 30 < 30 Co-58 < 10 < 10 < 10 < 10 Co-60 < 10 < 10 < 10 < 10 Zn-65 < 30 < 30 < 30 < 30 Zr-Nb-95 < 15 < 15 < 15 < 15 Cs-134 < 10 < 10 < 10 < 10 Cs-137 < 10 < 10 < 10 < 10 Ba-La-140 < 15 < 15 < 15 < 15 Ce-144 < 27 < 25 < 27 < 38 11-1
MONTICELLO Table 12. River water and drinking water, analysis of quarterly composites for tritium.
Collection: Quarterly composites of weekly collections.
Sample Type, Location and Concentration (pCi/L)
Collection Period Lab Code H-3 River Water Upstream, M-8 (C) 8 1st Quarter MSW- 2120 < 500 < 142 2nd Quarter MSW- 4727 < 500 < 152 3rd Quarter MSW 6835 < 500 < 144 4th Quarter MSW- 9235 < 500 < 143 Cumulative Average < 500 < 145 Previous Annual Average < 500 < 160 River Water Downstream, M-9 1st Quarter MSW- 2121 < 500 < 142 2nd Quarter MSW- 4728 < 500 < 152 3rd Quarter MSW- 6836 < 500 < 144 4th Quarter MSW- 9236 < 500 < 143 Cumulative Average < 500 < 145 Previous Annual Average < 500 < 159 Drinking Water Minneapolis, M-14 1st Quarter MDW 2122,3 < 500 < 142 2nd Quarter MDW 4728 < 500 < 152 3rd Quarter MDW- 6837 < 500 < 145 4th Quarter MDW- 9237 < 500 < 143 Cumulative Average < 500 < 146 Previous Annual Average < 500 < 153 a Composite consists of samples from 03-16, 03-23 and 03-30-11; water frozen remainder of quarter.
12-1
MONTICELLO Table 13. Well water, analysis for tritium and gamma-emitting isotopes.
Sample Description and Concentration (pCi/L)
Date H-3 Ol co 0 l{) (")
l{) l{) (!) (!) ~
Collected Lab Code (< 500 pCi/L) cb LL 0 6
0 6
N c 0 Ul Monticello (M-11) 1/26/2011 MWW-435 < 154 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 46 4/20/2011 MWW-2423 < 153 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 30 7/27/2011 MWW-5142 < 171 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 21 10/19/2011 MWW-7387 < 145 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 36 Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 46 Plant Well No.1 (M-12) 1/26/2011 MWW-436 < 154 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 33 4/20/2011 MWW-2424 < 153 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 41 7/27/2011 MWW 5143 < 171 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 22 10/19/2011 MWW-7388 < 145 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 20 Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 41 Wise (M-27) 1/26/2011 MWW-437 < 154 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 27 4/20/2011 MWW-2425 < 153 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 35 7/27/2011 MWW 5144 < 171 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 21 10/19/2011 MWW-7389 < 145 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 25 Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 35 lmholte (M-43) Control 1/26/2011 MWW-438 < 154 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 29 4/20/2011 MWW-2426 < 153 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 33 7/27/2011 MWW 5145 < 171 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 20 10/19/2011 MWW-7390 < 145 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 22 Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 33 13-1
MONTICELLO Table 13. Well water, analysis for tritium and gamma-emitting isotopes (continued).
Sample Description and Concentration (pCi/L) l()
Q)
'<t !'--
Date H-3 '<t Q) co 0 l() .0 I
(") (")
l()
c I
l() l()
6
<0 6
<0 I z .,-
1 1
cb c
~
Ul Ul Collected Lab Code (< 500 pCi/L) ::;:;: LL. u u N u u Monitoring Well #1 (M-33) 8 01-17-11 ND 02-25-11 MWW- 806 249 +/- 92 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 30 03-30-11 MWW- 1548 294 +/- 120 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 13 04-25-11 MWW- 2565 422 +/- 108 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 52 05-16-11 MWW- 3086 341 +/- 86 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 44 06-20-11 MWW- 3958 193 +/- 82 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 25 07-27-11 MWW- 5198 299 +/- 90 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 25 08-16-11 MWW- 5648 244 +/- 95 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 32 09-22-11 MWW- 6448 < 150 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 31 10-17-11 MWW- 7421 < 148 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 25 11-29-11 MWW- 8494 < 147 NDb 12-18-11 MWW- 8888 < 153 NDb Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 52 Monitoring Well #2 (M-34) 01-17-11 MWW- 310 213 +/- 79 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 39 02-25-11 MWW- 807 329 +/- 96 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 21 03-30-11 MWW- 1549 315 +/- 120 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 15 04-25-11 MWW- 2566 303 +/- 104 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 26 05-16-11 MWW- 3088 303 +/- 84 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 06-20-11 MWW- 3959 351 +/- 90 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 24 07-27-11 MWW- 5199 217 +/- 87 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 08-17-11 MWW- 5650 230 +/- 95 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 25 09-22-11 MWW- 6449 225 +/- 100 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 46 10-17-11 MWW-7422 226 +/- 85 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 20 11-29-11 MWW- 8495 350 +/- 94 NDb 12-18-11 MWW- 8889 181 +/- 89 NDb Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 46 a ND =No data; see Table 2.0, Listing of Missed Samples.
b ND No data; gamma isotopic analysis not required.
13-2
MONTICELLO Table 13. Well water, analysis for tritium and gamma-emitting isotopes (continued).
Sample Description and Concentration (pCi/L) 0 l{) '<t 0)
'<t r-- ~
'<t Date H-3 '<t l{)
- 0) co 0 l{) .6 (") (") ro '<t c l{) l{) CD <!( z ~ ~ ....J ~
cb 6 6 c '
(f) ' ro cb rS (f)
Collected Lab Code (< 500 pCi!L) :2: u.. 0 0 N 0 0 Ill 0 Monitoring Well #3 {M-35) 01-17-11 MWW- 311 427 +/- 88 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 30 02-25-11 MWW- 808 329 +/- 96 < 10 < 30 < 10 < 10 < 30 <15 < 10 < 10 < 15 < 28 03-30-11 MWW- 1550 318 +/- 120 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 29 04-25-11 MWW- 2567 240 +/-101 < 10 < 30 < 10 < 10 < 30 <15 < 10 <10 < 15 < 43 05-16-11 MWW- 3089 < 134 <10 < 30 < 10 < 10 < 30 < 15 < 10 <10 < 15 < 10 06-20-11 MWW- 3960 285 +/- 87 <10 < 30 < 10 < 10 < 30 <15 < 10 < 10 < 15 < 43 07-27-11 MWW- 5200 215 +/- 87 <10 < 30 <10 < 10 < 30 <15 < 10 < 10 <15 < 18 08-17-11 MWW- 5651 < 152 <10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 31 09-22-11 MWW- 6450 313 +/- 104 <10 < 30 <10 < 10 < 30 < 15 < 10 < 10 < 15 < 35 10-17-11 MWW-7423 256 +/- 86 <10 < 30 <10 < 10 < 30 < 15 < 10 < 10 <15 < 22 11-29-11 MWW- 8496 < 157 NOb 12-18-12 MWW- 8890 < 153 NOb Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 <15 < 10 < 10 < 15 < 43 Monitoring Well #4 (M-36) 01-18-11 MWW- 312 224 +/- 79 < 10 < 30 < 10 <10 < 30 < 15 < 10 <10 <15 < 27 02-25-11 MWW- 809 172 +/- 89 <10 < 30 < 10 < 10 < 30 <15 < 10 < 10 < 15 < 24 04-25-11 MWW- 2568 185 +/- 98 <10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 43 07-27-11 MWW- 5201 184 +/- 85 <10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 35 10-17-11 MWW-7424 < 148 <10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 <15 <17 Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 <15 < 10 < 10 < 15 < 43 b NO No data; gamma isotopic analysis not required.
13-3
MONTICELLO Table 13. Well water, analysis for tritium and gamma-emitting isotopes (continued).
Sample Description and Concentration (pCi/L) l!)
Cll r--
'<t Cll CX) 0 l!) _6 C')
Date H-3 l!)
I l!) l!) <D <D z ~ ~
c cb 6 6 t: ~
I
(/)
I
(/)
Collected Lab Code (< 500 pCi/L) ::2! lL () () N N () ()
Monitoring Well #5 (M-37) 01-18-11 MWW- 313 < 138 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 54 02-24-11 MWW- 810 < 160 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 20 04-25-11 MWW- 2569 < 148 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 29 07-27-11 MWW- 5202 < 144 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 28 1 0-16-11 MWW-7425 < 148 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 22 Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 54 Monitoring Well #6 (M-38) 01-17-11 MWW- 314 < 138 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 18 02-24-11 MWW- 811 < 160 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 24 04-25-11 MWW- 2570 < 148 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 41 07-27-11 MWW- 5203 < 144 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 18 10-16-11 MWW-7426 < 148 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 36 Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 41 Monitoring Well #7 (M-39) 01-17-11 MWW- 315 < 138 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 46 02-24-11 MWW- 812 < 160 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 22 04-25-11 MWW- 2571 < 148 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 07-27-11 MWW-5204 < 144 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 28 10-16-11 MWW-7428 < 148 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 19 Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 46 Monitoring Well #8 (M-40) 01-17-11 MWW- 316 < 138 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 42 02-24-11 MWW- 813 < 160 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 27 04-25-11 MWW-2572 < 148 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 18 07-27-11 MWW- 5205 < 144 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 10-16-11 MWW-7429 < 148 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 42 13-4
MONTICELLO Table 13. Well water, analysis for tritium and gamma-emitting isotopes (continued).
Sample Description and Concentration (pCi/L)
Ol co 0 l[)
Date H-3 l[) l[) co co Collected Lab Code (< 500 pCi/L) cb 6 6
()
t:
LL () N Monitoring Well #9A (M-44) 01-18-11 MWW- 288 2317 +/- 159 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 24 02-23-11 MWW- 905 820 +/- 126 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 28 03-30-11 MWW- 1551 246 +/- 118 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 29 04-25-11 MWW- 2573 231 +/- 100 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 27 05-17-11 MWW- 3126 1197 +/- 116 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 14 06-20-11 MWW- 4006 499 +/- 97 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 17 07-19-11 MWW- 4916 312 +/- 100 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 08-16-11 MWW- 5815 262 +/- 90 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 15 09-22-11 MWW- 6451 192 +/- 99 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 48 10-16-11 MWW- 7430 216 +/- 85 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 11-29-11 MWW- 8497 < 147 NDa 12-18-11 MWW- 8984 < 150 NDa Cumulative Averages 629 (10/10) < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 48 Monitoring Well #9B (M-51) 01-18-11 MWW- 289 181 +/- 90 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 34 02-23-11 MWW- 905 < 177 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 27 03-30-11 MWW- 1552 < 178 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 20 04-25-11 MWW- 2575 < 137 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 34 05-17-11 MWW- 3127 < 134 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 06-20-11 MWW- 4007 < 145 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 18 07-19-11 MWW- 4917 < 163 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 08-16-11 MWW- 5816 < 146 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 25 09-22-11 MWW- 6452 < 150 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 26 10-16-11 MWW- 7431 < 141 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 24 3
11-29-11 MWW- 8498 < 147 ND 12-18-11 MWW- 8985 < 150 NDa Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 34 Monitoring Well #10 (M-45) 01-18-11 MWW- 317 711 +/- 99 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 31 02-25-11 MWW- 814 769 +/- 115 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 03-30-11 MWW- 1553 685 +/- 133 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 29 04-25-11 MWW- 2576 694 +/- 104 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 05-16-11 MWW- 3090 552 +/- 94 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 17 06-20-11 MWW- 3961 570 +/- 100 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 30 07-27-11 MWW- 5206 615 +/- 104 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 17 08-16-11 MWW- 5652 540 +/- 107 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 25 09-23-11 MWW- 6453 585 +/- 114 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 36 10-17-11 MWW- 7432 482 +/- 97 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 18 11-29-11 MWW- 8499 601 +/-104 ND 3 12-18-11 MWW- 8891 395 +/- 98 NDa Cumulative Averages 619 (11/11) < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 36 a ND =No data; gamma isotopic analysis not required.
13-5
MONTICELLO Table 13. Well water, analysis for tritium and gamma-emitting isotopes (continued).
Sample Description and Concentration (pCi/L) 1'-
m co 0 L{) (Y)
Date H-3 L{) L{) <0 <0 ~
Collected Lab Code (< 500 pCi/L) 0 LL 0 6
0 6
N c 0 Ul Monitoring Well #11 (M-46) 01-18-11 MWW- 318 < 138 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 34 02-25-11 MWW- 815 258 +/- 93 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 21 03-30-11 MWW- 1554 239 +/- 118 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 22 04-25-11 MWW- 2577 277 +/- 86 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 43 05-16-11 MWW- 3091 183 +/- 79 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 27 06-20-11 MWW- 3962 < 145 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 29 07-27-11 MWW- 5207 212 +/- 86 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 08-16-11 MWW- 5653 < 152 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 13 09-23-11 MWW- 6454 < 149 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 36 10-17-11 MWW- 7433 < 148 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 26 11-29-11 MWW- 8500 < 147 NOb 12-18-11 MWW- 8892 < 153 NOb Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 43 Monitoring Well #12A (M-47) 3 01-17-11 ND 02-25-11 MWW- 816 < 160 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 28 03-30-11 MWW- 1555 < 156 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 27 04-25-11 MWW- 2578 < 137 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 50 05-16-11 MWW- 3092 < 134 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 27 06-20-11 MWW- 3963 272 +/- 86 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 21 07-24-11 MWW- 5208 < 144 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 12 08-17-11 MWW- 5654 < 139 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 21 09-23-11 MWW- 6455 < 149 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 56 10-17-11 MWW- 7434 < 148 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 14 11-30-11 MWW- 8501 < 147 NOb 12-18-11 MWW- 8893 < 153 NOb Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 56 Monitoring Well #12B (M-48) 01-18-11 MWW- 319 < 11 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 22 02-25-11 MWW- 817 < 113 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 22 03-30-11 MWW- 1556 < 156 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 21 04-25-11 MWW- 2579 < 139 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 19 05-16-11 MWW- 3093 < 134 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 36 06-20-11 MWW- 3964 < 145 <10 <30 <10 <10 <30 <15 <10 <10 <15 <25 07-24-11 MWW- 5209 < 144 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 10 08-17-11 MWW- 5655 < 139 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 34 09-23-11 MWW- 6457 < 149 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 24 10-17-11 MWW- 7435 < 148 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 25 11-30-11 MWW- 8502 < 147 NOb 12-18-11 MWW- 8894 < 153 NOb Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 36 aND= No data; See Table 2.0, Listing of Missed Samples.
c ND = No data; gamma isotopic analysis not required.
13-6
MONTICELLO Table 13. Well water, analysis for tritium and gamma-emitting isotopes (continued).
Sample Description and Concentration (pCi/L) 1.{)
Q)
Q) co 0 1.{) 1:,
Date H-3 1.{) 1.{) <0 <0 z Collected Lab Code (< 500 pCi/L) cb LL u 6
u 6
N c ~
Monitoring Well #13A (M-49) 01-18-11 MWW- 320 154 +/- 76 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 29 02-25-11 MWW- 818 201 +/-201 <10 <30 <10 <10 <30 <15 <10 <10 <15 <25 03-30-11 MWW- 1557 194 +/- 194 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 19 04-25-11 MWW- 2580 180 +/- 180 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 19 05-16-11 MWW- 3094 < 134 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 27 06-20-11 MWW- 3965 < 145 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 28 07-24-11 MWW- 5210 188 +/- 85 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 18 08-17-11 MWW- 5656 < 152 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 38 09-23-11 MWW- 6458 < 149 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 10-17-11 NDa 11-30-11 MWW- 8503 < 147 NOd 12-18-11 MWW- 8895 < 153 NOd Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 38 Monitoring Well #13B (M-50) 01-18-11 MWW- 321 150 +/- 76 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 42 02-25-11 MWW- 819 < 160 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 03-30-11 MWW- 1558 < 159 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 28 04-25-11 MWW- 2581 192 +/- 192 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 26 05-16-11 MWW- 3095 180 +/- 79 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 06-20-11 MWW- 3966 160 +/- 81 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 31 07-24-11 MWW- 5211 164 +/-59 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 30 08-17-11 MWW- 5657 < 152 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 36 09-23-11 MWW- 6459 < 149 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 17 10-17-11 MWW- 7436 < 148 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 20 11-30-11 MWW- 8504 178 +/- 86 NOd 12-18-11 MWW- 8896 < 153 NOd Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 42 Monitoring Well #14 01-17-11 MWW- 322 < 138 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 42 02-24-11 MWW- 820 < 160 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 03-30-11 b MWW- 1559 176 +/- 176 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 33 04-25-11 MWW- 2587 231 +/- 84 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 18 05-16-11 MWW- 3096 < 134 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 06-20-11 c MWW- 3967 189 +/- 82 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 24 07-19-11 MWW- 4715 < 152 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 25 08-16-11 MWW- 5658 < 152 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 30 09-23-11 MWW- 6460 < 150 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 10-16-11 MWW- 7437 < 148 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 23 11-29-11 MWW- 8505 < 147 NOd 12-18-11 MWW- 8897 < 153 NOd Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 42 aND= No data; See Table 2.0, Listing of Missed Samples.
b Recounted, result of recount: <162 pCi/L.
c Recounted, result of recount: <167 pCi/L.
d "ND" =No data; gamma isotopic analysis not required.
13-7
MONTICELLO Table 14. Fish, analysis of edible portions for gamma-emitting isotopes.
Collection: Semiannually Sample Description and Concentration (pCi!g wet) Cumulative Previous Average Average Upstream 1000' M-8 (C)
Date Collected 05-31-11 05-31-11 05-31-11 Lab Code MF- 3378 MF- 3380 MF- 3382 Sample Type Smallmouth Buffalo White Sucker Red horse K-40 3.21 +/- 0.39 2.74 +/- 0.36 2.86 +/- 0.38 2.98 3.09 Mn-54 < 0.014 < 0.013 < 0.015 < 0.014 < 0.010 Fe-59 < 0.021 < 0.017 < 0.023 < 0.021 < 0.029 Co-58 < 0.010 < 0.007 < 0.008 < 0.010 < 0.013 Co-60 < 0.010 < 0.013 < 0.008 < 0.013 < 0.012 Zn-65 < 0.012 < 0.010 < 0.012 < 0.012 < 0.032 Nb-95 < 0.013 < 0.010 < 0.010 < 0.013 < 0.016 Zr-95 < 0.018 < 0.019 < 0.025 < 0.019 < 0.027 Cs-134 < 0.011 < 0.011 < 0.013 < 0.011 < 0.015 Cs-137 < 0.014 < 0.013 < 0.010 < 0.014 < 0.014 Ba-La-140 < 0.018 < 0.015 < 0.019 < 0.018 < 0.058 Ce-144 < 0.075 < 0.092 < 0.074 < 0.092 < 0.072 Downstream 1000' M-9 Date Collected 05-31-11 05-31-11 05-31-11 Lab Code MF- 3379 MF- 3381 MF- 3383 Sample Type Smallmouth Buffalo White Sucker Red horse K-40 3.58 +/- 0.40 2.55 +/- 0.35 3.29 +/- 0.39 3.06 2.67 Mn-54 < 0.012 < 0.017 < 0.016 < 0.017 < 0.007 Fe-59 < 0.019 < 0.033 < 0.032 < 0.033 < 0.030 Co-58 < 0.009 < 0.011 < 0.010 < 0.011 < 0.017 Co-60 < 0.010 < 0.009 < 0.009 < 0.010 < 0.012 Zn-65 < 0.023 < 0.015 < 0.008 < 0.023 < 0.023 Nb-95 < 0.009 < 0.009 < 0.011 < 0.009 < 0.017 Zr-95 < 0.026 < 0.024 < 0.018 < 0.026 < 0.027 Cs-134 < 0.013 < 0.010 < 0.012 < 0.013 < 0.010 Cs-137 < 0.015 0.024 +/- 0.012 < 0.011 0.024 < 0.016 Ba-La-140 < 0.017 < 0.021 < 0.020 < 0.021 < 0.044 Ce-144 < 0.073 < 0.082 < 0.070 < 0.082 < 0.090 14-1
MONTICELLO Table 14. Fish, analysis of edible portions for gamma-emitting isotopes.
Collection: Semiannually Sample Description and Concentration (pCi!g wet) Cumulative Previous Average Average Upstream 1000' M-8 (C)
Date Collected 10-26-11 10-26-11 Lab Code MF- 7457 MF- 7458 Sample Type Short heads Smallmouth Bass K-40 2.75 +/- 0.45 3.05 +/- 0.40 2.90 3.09 Mn-54 < 0.021 < 0.015 < 0.021 < 0.010 Fe-59 < 0.044 < 0.030 < 0.044 < 0.029 Co-58 < 0.016 < 0.009 < 0.016 < 0.013 Co-60 < 0.016 < 0.017 < 0.017 < 0.012 Zn-65 < 0.032 < 0.020 < 0.032 < 0.032 Nb-95 < 0.018 < 0.017 < 0.018 < 0.016 Zr-95 < 0.024 < 0.030 < 0.030 < 0.027 Cs-134 < 0.020 < 0.010 < 0.020 < 0.015 Cs-137 < 0.023 < 0.015 < 0.023 < 0.014 Ba-La-140 < 0.048 < 0.047 < 0.048 < 0.058 Ce-144 < 0.158 < 0.095 < 0.158 < 0.072 Downstream 1000' M-9 Date Collected 10-26-11 10-26-11 Lab Code MF- 7459 MF- 7460 Sample Type Short heads Smallmouth Bass K-40 3.34 +/- 0.52 2.84 +/- 0.57 3.09 2.67 Mn-54 < 0.017 < 0.015 < 0.017 < 0.007 Fe-59 < 0.030 < 0.062 < 0.062 < 0.030 Co-58 < 0.022 < 0.028 < 0.028 < 0.017 Co-60 < 0.025 < 0.019 < 0.025 < 0.012 Zn-65 < 0.024 < 0.033 < 0.033 < 0.023 Nb-95 < 0.027 < 0.029 < 0.029 < 0.017 Zr-95 < 0.031 < 0.044 < 0.044 < 0.027 Cs-134 < 0.024 < 0.017 < 0.024 < 0.010 Cs-137 < 0.028 < 0.026 < 0.028 < 0.016 Ba-La-140 < 0.067 < 0.053 < 0.067 < 0.044 Ce-144 < 0.103 < 0.130 < 0.130 < 0.090 14-2
MONTICELLO Table 15. Algae or aquatic insects, analysis for gamma-emitting isotopes.
Collection: Semiannually Sample Description and Concentration (pCi/g wet) Cumulative Previous Average Average Upstream 1000' M-8 (C) 8 Date Collected Lab Code Be-7 < 0.64 K-40 < 1.35 Mn-54 < 0.07 Fe-59 < 0.09 Co-58 < 0.06 Co-60 < 0.03 Zn-65 < 0.13 Zr-Nb-95 < 0.08 Ru-103 < 0.06 Ru-106 < 0.45 Cs-134 < 0.05 Cs-137 < 0.05 Ba-La-140 < 0.17 Ce-144 < 0.24 Downstream 1000' M-9 Date Collected 09-29-11 Lab Code MBO- 6608 Be-7 < 0.33 < 0.33 < 0.60 K-40 < 0.65 < 0.65 < 1.89 Mn-54 < 0.02 < 0.02 < 0.07 Fe-59 < 0.07 < 0.07 < 0.07 Co-58 < 0.04 < 0.04 < 0.07 Co-60 < 0.02 < 0.02 < 0.07 Zn-65 < 0.06 < 0.06 < 0.14 Zr-Nb-95 < 0.04 < 0.04 < 0.09 Ru-103 < 0.05 < 0.05 < 0.06 Ru-106 < 0.31 < 0.31 < 0.42 Cs-134 < 0.04 < 0.04 < 0.06 Cs-137 < 0.04 < 0.04 < 0.07 Ba-La-140 < 0.07 < 0.07 < 0.15 Ce-144 < 0.12 < 0.12 < 0.37 aND = No data; see Table 2.0, Listing of Missed Samples.
15-1
MONTICELLO Table 16. Edible cultivated (irrigated) crops, analysis for iodine-131 and gamma-emitting isotopes.
Collection: Annually Sample Description and Concentration (pCi/g wet)
Location: Control (Cabbage)
Date Collected Lab Code NDa Mn-54 -
Fe-59 -
Co-58 -
Co-60 -
Zn-65 -
Nb-95 -
I-131 -
Cs-134 -
Cs-137 -
Location: M-27 (Cabbage)
Date Collected Lab Code NDa Mn-54 -
Fe-59 -
Co-58 -
Co-60 -
Zn-65 -
Nb-95 -
I-131 -
Cs-134 -
Cs-137 -
a ND = No data; sample not collected.
16-1
MONTICELLO Table 17. Shoreline (SS) sediments, analysis for gamma-emitting isotopes.
Collection: Semiannually Sample Description and Concentration (pCi/g dry) Cumulative Previous Average Average Upstream 1000' M-8 (C)
Date Collected 07-13-11 10-26-11 Lab Code MSS- 4607 MSS- 7494 Be-7 < 0.20 < 0.073 < 0.20 < 0.21 K-40 11.48 +/- 0.63 9.51 +/- 0.53 10.50 10.03 Mn-54 < 0.012 < 0.014 < 0.014 < 0.026 Fe-59 < 0.040 < 0.027 < 0.040 < 0.053 Co-58 < 0.018 < 0.017 < 0.018 < 0.029 Co-60 < 0.011 < 0.006 < 0.011 < 0.024 Zn-65 < 0.032 < 0.034 < 0.034 < 0.073 Nb-95 < 0.026 < 0.021 < 0.026 < 0.023 Zr-95 < 0.038 < 0.020 < 0.038 < 0.041 Ru-103 < 0.022 < 0.016 < 0.022 < 0.027 Ru-106 < 0.16 < 0.093 < 0.16 < 0.14 Cs-134 < 0.013 < 0.012 < 0.013 < 0.023 Cs-137 < 0.013 < 0.014 < 0.014 < 0.031 Ba-La-140 < 0.064 < 0.043 < 0.064 < 0.025 Ce-144 < 0.11 < 0.098 < 0.11 < 0.13 Downstream 1000' M-9 Date Collected 07-13-11 10-26-11 Lab Code MSS- 4608 MSS- 7495 Be-7 < 0.27 < 0.18 < 0.27 0.20 K-40 11.35+/-0.71 10.16 +/- 0.55 10.75 10.55 Mn-54 < 0.022 < 0.020 < 0.022 < 0.025 Fe-59 < 0.068 < 0.033 < 0.068 < 0.051 Co-58 < 0.021 < 0.018 < 0.021 < 0.029 Co-60 < 0.018 < 0.010 < 0.018 < 0.018 Zn-65 < 0.040 < 0.039 < 0.040 < 0.068 Nb-95 < 0.034 < 0.022 < 0.034 < 0.037 Zr-95 < 0.048 < 0.019 < 0.048 < 0.049 Ru-103 < 0.027 < 0.022 < 0.027 < 0.012 Ru-106 < 0.16 < 0.13 < 0.16 < 0.17 Cs-134 < 0.015 < 0.016 < 0.016 < 0.020 Cs-137 0.091 +/- 0.027 0.040 +/- 0.023 0.065 0.082 Ba-La-140 < 0.055 < 0.046 < 0.055 < 0.025 Ce-144 < 0.14 < 0.090 < 0.14 < 0.139 17-1
MONTICELLO Table 17. Shoreline (SS) sediments, analysis for gamma-emitting isotopes (continued).
Sample Description and Concentration (pCi/g dry) Cumulative Previous Average Average Montissippi Park M-15 Date Collected 07-13-11 10-26-11 Lab Code MSS- 4609 MSS- 7497 Be-7 < 0.18 < 0.18 < 0.18 0.17 K-40 9.92 +/- 0.55 9.78 +/- 0.53 9.85 11.04 Mn-54 < 0.015 < 0.014 <0.015 <0.015 Fe-59 < 0.046 < 0.042 <0.046 <0.051 Co-58 < 0.012 < 0.015 <0.015 <0.020 Co-60 < 0.009 < 0.013 <0.013 <0.011 Zn-65 < 0.042 < 0.042 <0.042 <0.059 Nb-95 < 0.021 < 0.038 <0.038 <0.016 Zr-95 < 0.039 < 0.020 <0.039 <0.022 Ru-103 < 0.018 < 0.018 <0.018 <0.021 Ru-106 < 0.067 < 0.12 <0.117 < 0.130 Cs-134 < 0.013 < 0.010 <0.013 <0.013 Cs-137 < 0.015 0.028 +/- 0.016 0.028 0.060 Ba-La-140 < 0.039 < 0.034 <0.039 <0.025 Ce-144 < 0.084 < 0.092 < 0.092 < 0.108 17-2
MONTICELLO Table 18. Storm run-off, analysis for tritium and gamma-emitting isotopes.
Sewer llift station, analysis for tritium.
Sample Description and Concentration (pCi/L)
Date Collected 02-22-11 04-26-11 05-31-11 06-15-11 Lab Code MXW- 657 MXW- 2525 MXW- 3401 MXW- 3869 H-3 a 772 +/- 125 585 +/- 108 <144 < 146 Mn-54 < 2.6 < 6.6 < 3.4 < 4.3 Fe-59 < 3.5 < 7.9 < 5.9 < 5.7 Co-58 < 1.9 < 4.0 < 3.1 < 3.8 Co-60 < 3.3 < 4.3 < 3.2 < 4.4 Zn-65 < 4.0 < 8.4 < 7.8 < 5.5 Zr-Nb-95 < 2.2 < 7.1 < 3.4 < 4.7 1-131 < 5.3 < 11.5 < 4.3 < 8.3 Cs-134 < 2.6 < 6.7 < 4.0 < 2.7 Cs-137 < 3.1 < 4.6 < 4.1 < 4.7 La-140 < 3.2 < 9.8 < 6.4 < 6.4 Ce-144 < 26.3 < 45.3 < 27.1 < 29.7 Date Collected 07-15-11 10-12-11 11-29-11 Lab Code MXW- 5213 MXW- 7391 MXW- 8446 H-3 a < 144 < 145 < 147 Mn-54 < 0.8 < 2.1 < 4.1 Fe-59 < 2.0 < 5.7 < 7.1 Co-58 < 0.7 < 2.6 < 5.5 Co-60 < 1.1 < 2.1 < 2.5 Zn-65 < 2.5 < 4.7 < 7.6 Zr-Nb-95 < 1.9 < 3.3 < 3.6 1-131 < 6.4 < 10.8 < 9.3 Cs-134 < 0.9 < 2.2 < 5.1 Cs-137 < 1.0 < 2.5 < 4.7 La-140 < 4.6 < 4.3 < 2.7 Ce-144 < 9.6 < 27.5 < 33.5 a Required LLD, < 500 pCi/L.
18-1
APPENDIX A IODINE-131 ACTIVITY DETECTED IN REMP AIR SAMPLES A-1
A-1. lodine-131 Activity Detected in REMP Air Samples 3 3 Location Coil. Date Lab Code Vol (m ) 1-131 (pCi/m )
M-01 03/23/11 MCH- 1671 294.5 0.059 +/- 0.026 M-02 03/23/11 MCH- 1672 295.0 0.076 +/- 0.018 M-03 03/23/11 MCH- 1673 295.1 0.071 +/- 0.020 M-04 03/23/11 MCH- 1674 195.6 0.098 +/- 0.021 M-05 03/23/11 MCH- 1675 294.5 0.077 +/- 0.022 M-01 03/30/11 MCH- 1861 293.6 0.066 +/- 0.027 M-02 03/30/11 MCH- 1862 292.8 0.055 +/- 0.027 M-03 03/30/11 MCH- 1863 292.7 0.050 +/- 0.026 M-04 03/30/11 MCH- 1864 194.7 0.061 +/- 0.027 M-05 03/30/11 MCH- 1865 293.2 0.047 +/- 0.026 M-01 04/06/11 MCH- 1961 294.0 0.112 +/- 0.025 M-02 04/06/11 MCH- 1962 293.7 0.089 +/- 0.022 M-03 04/06/11 MCH- 1963 293.7 0.098 +/- 0.019 M-04 04/06/11 MCH- 1964 195.3 0.134 +/- 0.031 M-05 04/06/11 MCH- 1965 294.0 0.113 +/- 0.031 M-01 04/13/11 MCH- 2091 295.2 0.031 +/- 0.017 M-02 04/13/11 MCH- 2092 295.0 0.036 +/- 0.018 A-2
ENCLOSURE 2 CORRECTIONS TO THE 2012 AREOR 1 page to Follow
L-MT-16-035 Page 1 of 1 Broadleaf vegetation samples were not collected since 2011 due to unavailability; these samples were not included as missed samples, because they were considered to be above and beyond required samples. Since they were included in the Offsite Dose Calculation Manual (ODCM) ODCM-07.01 Table 1, they were required samples for Monticello Nuclear Generating Plant and should have been included as missed samples. The affected pages have been included in their entirety (Attachment 1) and should replace existing pages (5 and 17), ML13135A006.
The complete data tables were to be submitted as part of the report; however, this data was not included with the annual reports prior to 2013. Attachment 2 will be added to the back of the annual report as submitted; this this will be an addition to the report and will not be replacing any pages in the report.
ENCLOSURE 2 ATTACHMENT 1 REPLACEMENT PAGES FOR THE 2012 AREOR 2 Pages to Follow
3.3 Program Execution The Program was executed as described in the preceding section with the following exceptions:
(1) Air Particulates / Air Iodine:
M-02. Volume for the week ending January 4, 2012 was lower than expected. A short power outage is suspected.
No air particulate sample was collected for the week ending June 27, 2012, the filter was misaligned in the holder.
M-03. No air particulate / air iodine sample was available for the week ending May 9, 2012, the timer reading was low due to power interruption.
No air particulate sample was collected for the week ending June 27, 2012, the filter was misaligned in the holder.
No air particulate / air iodine sample was available for the week ending July 18, 2012, low volume due to power interruption.
M-04. No air particulate / air iodine sample was available for the week ending May 30, 2012, the timer reading was low due to power interruption.
M-05. No air particulate / air iodine sample was available for the week ending May 30, 2012, the volume was low due to power interruption.
(2) Thermoluminescent Dosimeters:
The TLD for location M-01B was missing in the field for the first quarter, 2012.
The TLD for location M-08A was missing in the field for the first quarter, 2012.
The TLD for location M-11A was missing in the field for the fourth quarter, 2012.
(3) Surface Water:
Surface water was not collected at location M-08 for the weeks ending January 25 through February 15, 2012. The water was not collected due to unsafe ice conditions.
Both the January and February monthly composite samples were made up from available collections.
(4) Well Water:
Well water was not collected at location MW-27 in January, 2012. The outside well was locked and the residence was vacant.
(5) Milk Milk was not available from locations M-16 and M-17 for the January through March, 2012 collections. No milk was available after November 7, 2012.
(6) Invertebrates Bottom organisms were not collected in the Spring of 2012, due to high river levels.
(7) Shoreline Sediments Shoreline sediment was not collected in the Spring of 2012, due to high river levels.
(8) Broad Leaf Vegetable Broad Leaf Vegetables were not collected in 2012 due to unavailability. The previous Critical Garden ceased to be used and attempts to obtain a sample from the new Critical Garden were unsuccessful.
Deviations from the program are summarized in Table 5.3.
5
Table 5.3. MISSED COLLECTIONS AND ANALYSES All required samples were collected and analyzed as scheduled with the following exceptions:
Collection Reason for not Sample Analysis Location (s) Date or conducting REMP Plans for Preventing Type Period as required Recurrence AP/AI Beta, I-131 M-2 1/4/2012 Low sample volume. Short power Power restored.
outage suspected.
AP/AI Beta, I-131 M-3 5/9/2012 Low timer reading, possible power Power restored.
failure.
AP/AI Beta, I-131 M-3, M-4, M-5 5/30/2012 Low timer reading, power interruption. Power restored.
AP Beta, I-131 M-2, M-3 6/27/2012 Filters misaligned in holder, Technician training no particulate accumulation. reviewed SW For composite M-08 1/25/2012 Water frozen. None Required SW For composite M-08 2/1, 2/8, Water frozen. None Required 2/15, 2012 SW For composite M-08 12/15/2012 Water frozen. None Required WW Gamma, H-3 M-27 1/18/2012 Outside well locked; residence vacant. None Required WW Gamma, H-3 MW-14 10/17/2012 Well not collected. Well contents frozen.
MI Gamma, I-131 M-16, 17 1/31/2012 Milking discontinued until Spring. None Required MI Gamma, I-131 M-16, 17 12/31/2012 Milking discontinued for the year. None Required TLD Gamma M-1B, M-8A 1st Qtr. 2012 TLD missing in field. Replaced, vandalism TLD Gamma M-11A 4th Qtr. 2012 TLD missing in field. Replaced, vandalism BO Gamma M-8, M-9 Spring High water prevented sampling. None Required SS Gamma M-8, M-9 Spring High water prevented sampling. None Required Highest D/Q Samples became unavailable when Attempted to obtain a VE I-131 Garden and At Harvest previous critical garden ceased to be sample from new Control used. Critical Garden 17
ENCLOSURE 2 ATTACHMENT 2 ADDITIONAL PAGES FOR THE 2012 AREOR 30 Pages to Follow
ATI Environmental, Inc.
1"\1 Midwest laboratory 700 Landwehr Road
- Northbrook /L 60062-2310 phone (847) 564-0700
- fax (847) 564-4517 FINAL REPORT TO XCEL ENERGY CORPORATION RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM (REMP)
MONTICELLO NUCLEAR GENERATING PLANT DOCKET NO. 50-263 LICENSE NO. DPR-22 COMPLETE ANALYSES DATA TABLES January- December, 2012 Prepared under contract by ENVIRONMENTAL, INC.
MIDWEST LABORATORY PROJECT NO. 8010 Reviewed and Approved
MNGP TABLE OF CONTENTS Section Page List of Tables.................................................................................................................. iii
1.0 INTRODUCTION
........................................................................................................... . iv 2.0 LISTING OF MISSED SAMPLES .................................................................................. . v 3.0 DATA TABLES ............................................................................................................... vi ii
MNGP LIST OF TABLES Ambient radiation as measured by thermoluminescent dosimeters (TLDs)................................. 1-1 2 Airborne particulates and iodine collected at Location M-1 (C), analysis for gross beta and iodine-131 ............................................................................................................... 2-1 3 Airborne particulates and iodine collected at Location M-2, analysis for gross beta and iodine-131 ...................................................................................................................... 3-1 4 Airborne particulates and iodine collected at Location M-3, analysis for gross beta and iodine-131 ...................................................................................................................... 4-1 5 Airborne particulates and iodine collected at Location M-4, analysis for gross beta and iodine-131 ...................................................................................................................... 5-1 6 Airborne particulates and iodine collected at Location M-5, analysis for gross beta and iodine-131 ...................................................................................................................... 6-1 7 Airborne particulates, analysis for gross beta, monthly averages................................................ 7-1 8 Airborne particulate samples, quarterly composites from each location, analysis for gamma-emitting 8-1 9 Milk, analysis for iodine-131 and gamma emitting isotopes......................................................... 9-1 9A Pasture Grass, vegetation, analysis for iodine-131 and gamma emitting isotopes...................... 9A-1 10 River water, upstream, M-8 (C) and M-9, analysis of monthly composites for gamma-emitting isotopes............................................................................................................ 10-1 11 Drinking water, City of Minneapolis, M-14, analysis of monthly composites for gross beta, iodine-131 and gamma-emitting isotopes............................................................. 11-1 12 River water and drinking water, analysis of quarterly composites for tritium................................ 12-1 13 Well water, analysis for tritium and gamma-emitting isotopes..................................................... 13-1 14 Fish, analysis of edible portions for gamma-emitting isotopes .................................................... 14-1 15 Algae or aquatic insects, analysis for gamma-emitting isotopes .. ........ .................. ..................... 15-1 16 Edible cultivated (irrigated) crops, analysis for iodine-131 and gamma-emitting isotopes. .. .. .. . .. .. . .. .... . ... .. .. .. ... ..... .. ... .. .. .. .. .. .. .. ... .. . .. .. .. .. .... ... ....... .... .. .... .. .. ... .... ................ 16-1 17 Shoreline sediments, analysis for gamma-emitting isotopes....................................................... 17-1 iii
1.0 INTRODUCTION
The following constitutes the final 2012 report for the Environmental Radiological Monitoring Program conducted at the Monticello Nuclear Generating Plant in Monticello, Minnesota.
Results of completed analyses are presented in the attached tables.
All concentrations, except gross beta, are decay corrected to the time of collection.
All samples were collected within the scheduled period unless noted otherwise in the of Missed Samples.
iv
2.0. LISTING of MISSED SAMPLES All required samples were collected and analyzed as scheduled with the following exceptions:
Collection Reason for not Sample Analysis Location (s) Date or conducting REMP Plans for Preventing Type Period as required Recurrence AP/AI Beta, I-131 M-2 1/4/2012 Low sample volume. Short power Power restored.
outage suspected.
AP/AI Beta, I-131 M-3 5/9/2012 Low timer reading, possible power Power restored.
failure.
AP/AI Beta, I-131 M-3, M-4, M-5 5/30/2012 Low timer reading, power interruption. Power restored.
AP Beta, I-131 M-2, M-3 6/27/2012 Filters misaligned in holder, Technician training no particulate accumulation. reviewed SW For composite M-08 1/25/2012 Water frozen. None Required SW For composite M-08 2/1, 2/8, Water frozen. None Required 2/15, 2012 SW For composite M-08 12/15/2012 Water frozen. None Required WW Gamma, H-3 M-27 1/18/2012 Outside well locked; residence vacant. None Required WW Gamma, H-3 MW-14 10/17/2012 Well not collected. Well contents frozen.
MI Gamma, I-131 M-16, 17 1/31/2012 Milking discontinued until Spring. None Required MI Gamma, I-131 M-16, 17 12/31/2012 Milking discontinued for the year. None Required TLD Gamma M-1B, M-8A 1st Qtr. 2012 TLD missing in field. Replaced, vandalism TLD Gamma M-11A 4th Qtr. 2012 TLD missing in field. Replaced, vandalism BO Gamma M-8, M-9 Spring High water prevented sampling. None Required SS Gamma M-8, M-9 Spring High water prevented sampling. None Required Highest D/Q Samples became unavailable when Attempted to obtain a VE I-131 Garden and At Harvest previous critical garden ceased to be sample from new Control used. Critical Garden v
MNGP 3.0 DATA TABLES vi
MONTICELLO Table 1. Ambient gamma radiation as measured by thermoluminescent dosimeters (TLD's).
Previous mRem/91 days Cumulative Annual Location 1st Qtr. 2nd Qtr. 3rd Qtr. 4th Qtr. Average Average Indicators (Inner Ring, General Area of Site Boundary)
M-01A 12.7 +/- 1.2 14.2+/-1.2 13.1 +/- 1.4 16.0+/-1.3 14.0 12.9 M-02A 14.9 +/- 0.8 15.8 +/-0.8 15.5 +/- 1.1 18.5 +/- 0.7 16.2 15.0 M-03A 15.2 +/- 1.3 15.7+/-1.2 15.8+/-1.2 17.0 +/- 1.1 15.9 14.8 M-04A 14.1 +/- 0.9 16.0 +/- 0.8 14.6+/-1.0 18.0 +/-0.7 15.7 14.3 M-05A 14.6 +/- 0.9 16.9 +/- 1.0 14.6+/-1.0 18.4 +/-0.9 16.1 14.6 M-06A 15.4 +/- 0.8 16.8 +/- 0.8 16.0 +/- 1.1 18.8 +/- 0.8 16.8 15.3 M-07A 15.7 +/- 0.8 17.3 +/- 0.8 15.7 +/- 1.0 17.8 +/- 0.6 16.6 15.2 M-08A ND a 16.0+/-1.0 17.4+/-0.8 18.8 +/- 0.7 M-09A 16.2 +/- 1.0 16.6 +/- 0.9 15.8+/-1.7 17.9 +/- 0.8 16.6 15.3 M-10A 15.5+/-1.0 17.7+/-1.0 15.1 +/- 1.0 18.7 +/- 1.0 16.8 14.8 M-11A 18.0 +/- 0.7 18.3 +/- 0.8 17.0 +/- 1.2 ND a 17.8 16.3 M-12A 15.7 +/- 0.9 18.3 +/- 0.8 15.4+/-1.0 19.1+/-0.7 17.1 15.5 M-13A 14.1+/-0.8 14.3 +/- 0.9 14.2 +/- 1.1 15.4 +/- 0.7 14.5 13.5 M-14A 15.5 +/- 0.6 16.5 +/- 0.9 15.6 +/- 0.9 17.3 +/- 0.8 14.7 Mean+/- s.d. 15.2+/-1.2 16.5+/-1.3 15.4 +/- 1.1 17.8 +/- 1.1 16.2 14.8 Indicators (Outer Ring, 4-5 Miles Distant)
M-01B ND 8 15.5 +/- 1.5 15.2+/-1.4 16.3+/-1.2 M-02B 14.9 +/- 0.8 15.8+/-1.2 14.7 +/- 1.1 15.9 +/- 0.6 15.3 14.5 M-038 12.2 +/- 0.7 12.5 +/- 0.9 12.6+/-1.5 14.0 +/- 0.7 12.8 12.4 M-048 13.4 +/- 0.4 15.2 +/- 0.9 13.5 +/- 0.8 15.8 +/-0.7 14.5 13.6 M-05B 15.3 +/-0.6 15.6 +/- 1.2 14.8 +/-0.9 17.1 +/- 1.5 15.7 14.8 M-068 15.3 +/- 0.8 16.6+/-1.0 14.6 +/- 0.8 16.8 +/- 0.7 15.8 14.8 M-078 17.1 +/- 1.1 16.9+/-1.6 16.7 +/- 1.1 17.0 +/- 1.1 16.9 15.8 M-08B 14.4 +/-0.6 15.9 +/- 1.0 13.4 +/- 0.7 16.3 +/- 0.7 15.0 14.5 M-09B 16.2 +/- 0.9 18.3 +/- 0.9 15.9+/-1.0 18.2 +/- 0.9 17.2 15.5 M-10B 16.8 +/- 0.9 16.9 +/- 1.1 16.6 +/- 1.1 17.2+/-1.0 16.9 15.3 M-11B 15.8 +/- 0.9 17.7+/-1.0 15.6+/-1.2 17.6 +/- 1.1 16.7 15.0 M-12B 15.2+/-1.0 17.4+/-1.0 15.0 +/- 0.9 17.3 +/- 0.7 16.2 14.9 M-13B 14.2 +/- 0.5 15.6 +/- 0.9 14.0 +/- 0.9 15.4 +/- 0.8 14.8 13.8 M-14B 16.4 +/- 1.4 17.2 +/-0.9 15.3 +/- 1.3 17.2 +/- 0.7 16.5 14.4 M-15B 15.0 +/- 0.7 15.9 +/- 1.1 14.0 +/- 1.1 15.8 +/- 0.8 15.2 14.0 M-16B 13.2 +/- 0.7 14.3 + 1.1 12.1 + 0.8 14.1 + 1.1 13.4 13.2 Mean+/- s.d. 15.0+/-1.4 16.1 +/- 1.4 14.6+/-1.3 16.4 +/- 1.2 15.5 14.3 aND= No Data; see Table 2.0, Listing of Missed Samples.
1-1
MONTICELLO Table 1. Ambient gamma radiation as measured by thermoluminescent dosimeters (TLD's),
(continued).
Previous mRem/91 days Cumulative Annual Location 1st Qtr. 2nd Qtr. 3rd Qtr. 4th Qtr. Average Average Control M-01C 16.0 +/- 0.8 16.0+/-1.1 16.3 +/- 1.1 15.5 +/- 0.8 16.0 14.8 M-02C 16.7 +/- 1.2 17.3 +/- 0.9 17.4+/-1.5 16.7 +/- 0.8 17.0 15.4 M-03C 18.3 +/- 0.5 18.7 +/- 0.9 18.3 +/- 0.7 17.3 +/- 0.7 18.2 16.5 M-04C 17.0 +/-0.6 16.9+/-1.4 16.4 +/- 0.8 16.0 +/- 0.5 16.6 15.2 Mean+/- s.d. 17.0+/-1.0 17.2 +/- 1.1 17.1 +/- 0.9 16.4 +/-0.8 16.9 15.5 Indicators (Special Interest Areas)
M-018 13.0+/-1.1 14.9 +/- 0.8 12.0+/-1.2 15.3 +/- 0.5 13.8 12.7 M-028 12.4 +/- 0.9 13.7 +/- 0.8 12.0 +/- 0.8 13.5 +/- 0.7 12.9 11.9 M-03S 5.2 +/- 1.0 6.1 +/-1.0 14.4 +/- .1 15.7 +/- 1.0 15.4 14.2 M-048 16.1 +/- 0.9 15.8 +/- 1.2 15.4 +/- 1.1 15.5 +/- 0.7 15.7 14.7 M-058 11.9+/-0.6 17.0 +/- 1.2 12.6 +/-0.8 16.1 +/- 1.0 14.4 14.5 M-068 17.9 +/- 0.8 17.9 +/- 0.9 17.3+/-1.2 17.2 +/-0.8 17.6 17.0 Mean+/- s.d. 14.4 +/-2.4 15.9+/-1.5 14.0 +/- 2.1 15.6+/-1.2 15.0 14.1 Special TLDs M-1-01 94.7 +/- 2.6 108.3 +/- 3.5 83.4 +/- 4.7 115.4 +/- 5.5 100.5 67.7 M-1-02 80.4 +/- 2.8 89.0+/-1.2 70.9 +/- 3.4 93.7 +/- 1.1 83.5 56.9 M-1-03 50.6 +/- 2.7 64.9 +/- 1.9 53.1+/-3.8 60.1+/-2.1 57.2 37.4 M-1-04 41.4 +/- 1.8 42.8 +/- 1.9 36.5 +/- 1.6 40.7 +/- 2.0 40.4 32.6 M-1-05 52.2 +/- 2.8 57.0 +/- 2.1 48.6 +/- 3.1 54.0 +/- 1.9 53.0 44.8 M-1-06 30.9 +/- 1.5 33.9+/-1.1 29.2+/-1.7 32.4+/-1.0 31.6 26.1 M-1-07 35.1 +/- 1.0 40.4+/-1.3 32.8 +/- 1.7 37.7+/-1.9 36.5 29.9 M-1-08 34.0 +/- 2.0 36.1 +/- 2.8 32.1+/-2.1 32.6 +/- 1.6 33.7 26.8 M-1-09 63.3 +/- 1.8 70.3 +/- 4.2 56.9 +/- 2.9 63.4 +/- 3.5 63.5 51.6 M-1-10 54.4 +/- 2.1 57.7 +/- 2.3 50.3 +/- 2.1 53.4 +/- 2.8 54.0 42.1 M-1-11 17.9 +/- 1.2 16.7 +/- 0.7 17.9+/-1.4 16.4 +/- 0.6 17.2 15.5 M-1-12 16.5 +/- 0.5 17.7 +/- 0.9 16.4 +/- 0.7 17.3 +/- 0.6 17.0 15.0 M-1-13 18.8 +/- 1.9 18.0 +/- 1.2 18.5+/-1.9 17.4 +/- 1.1 18.2 16.0 Mean+/- s.d. 45.4 +/- 24.0 50.2 +/- 28.0 42.0 +/- 20.8 48.8 +/- 29.7 46.6 35.6 1-2
MONTICELLO 8
Table 2. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 .
Location: M-1 (C) 3 Units: pCi/m Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (m3) Gross Beta Collected (m3) Gross Beta Required LLD 0.010 Required LLD 0.010 01-04-12 328 0.035 +/- 0.004 07-11-12 475 0.021 +/- 0.003 01-11-12 324 0.028 +/- 0.003 07-18-12 409 0.036 +/- 0.003 01-18-12 323 0.036 +/- 0.004 07-25-12 414 0.026 +/- 0.003 01-25-12 353 0.044 +/- 0.004 08-01-12 413 0.020 +/- 0.003 02-01-12 324 0.036 +/- 0.004 08-07-12 323 0.026 +/- 0.003 02-08-12 351 0.025 +/- 0.003 08-14-12 414 0.018 +/- 0.003 02-15-12 327 0.035 +/- 0.004 08-21-12 382 0.019 +/- 0.003 02-22-12 322 0.033 +/- 0.004 08-28-12 355 0.038 +/- 0.004 02-29-12 300 0.036 +/- 0.004 09-05-12 401 0.037 +/- 0.003 03-07-12 314 0.033 +/- 0.004 09-11-12 303 0.018 +/- 0.003 03-15-12 369 0.033 +/- 0.003 09-19-12 405 0.025 +/- 0.003 03-21-12 303 0.021 +/- 0.003 09-26-12 323 0.016 +/- 0.003 03-28-12 321 0.016 +/- 0.003 10-03-12 353 0.037 +/- 0.004 1st Quarter Mean +/- s.d. 0.032 +/- 0.007 3rd Quarter Mean +/- s.d. 0.026 +/- 0.008 04-04-12 325 0.015 +/-0.003 10-10-12 351 0.016 +/- 0.003 04-11-12 325 0.017 +/- 0.003 10-17-12 326 0.036 +/- 0.004 04-18-12 355 0.020 +/- 0.003 10-24-12 352 0.027 +/- 0.003 04-25-12 323 0.022 +/- 0.003 10-31-12 383 0.031 +/- 0.003 05-02-12 353 0.022 +/- 0.003 11-07-12 354 0.031 +/- 0.003 05-09-12 381 0.014 +/- 0.003 11-14-12 366 0.036 +/- 0.004 05-16-12 349 0.018 +/- 0.003 11-21-12 355 0.084 +/- 0.005 05-23-12 370 0.026 +/- 0.003 11-28-12 351 0.036 +/- 0.004 05-30-12 349 0.011 +/- 0.003 12-05-12 353 0.081 +/- 0.005 06-06-12 366 0.020 +/- 0.003 12-12-12 325 0.054 +/- 0.004 06-13-12 380 0.022 +/- 0.003 12-19-12 351 0.061 +/- 0.004 06-20-12 384 0.018 +/- 0.003 12-27-12 403 0.050 +/- 0.004 06-27-12 382 0.020 +/- 0.003 01-02-13 279 0.097 +/- 0.006 07-03-12 302 0.034 +/- 0.004 2nd Quarter Mean +/- s.d. 0.020 +/- 0.006 4th Quarter Mean +/- s.d. 0.049 +/- 0.025 Cumulative Average 0.031 Previous Annual Average 0.027 3
a lodine-131 concentrations are< 0.03 pCi/m unless otherwise noted.
2-1
MONTICELLO Table 3. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 8 .
Location: M-2 3
Units: pCi/m Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (m:;) Gross Beta Collected (m:;) Gross Beta Reguired LLD 0.010 0.010 01-04-12 300 0.033 +/- 0.004 07-11-12 406 0.023 +/- 0.003 01-11-12 324 0.026 +/- 0.003 07-18-12 348 0.034 +/- 0.004 01-18-12 298 0.035 +/- 0.004 07-25-12 353 0.028 +/- 0.003 01-25-12 349 0.044 +/- 0.004 08-01-12 349 0.023 +/- 0.003 02-01-12 326 0.031 +/- 0.003 08-07-12 325 0.020 +/- 0.003 02-08-12 350 0.029 +/- 0.003 08-14-12 358 0.015 +/- 0.003 02-15-12 357 0.029 +/- 0.003 08-21-12 349 0.020 +/- 0.003 02-22-12 324 0.033 +/- 0.004 08-28-12 353 0.039 +/- 0.004 02-29-12 331 0.033 +/- 0.004 09-05-12 401 0.036 +/- 0.003 03-07-12 319 0.034 +/- 0.004 09-11-12 303 0.019 +/- 0.003 03-15-12 371 0.029 +/- 0.003 09-19-12 376 0.026 0.003 03-21-12 303 0.022 +/- 0.003 09-26-12 325 0.016 +/- 0.003 03-28-12 322 0.018 +/- 0.003 10-03-12 326 0.036 +/- 0.004 1st Quarter Mean +/- s.d. 0.031 +/- 0.006 3rd Quarter Mean +/- s.d. 0.026 +/- 0.008 04-04-12 326 0.013 +/- 0.003 10-10-12 350 0.020 +/- 0.003 04-11-12 329 0.019 +/- 0.003 10-17-12 305 0.042 +/- 0.004 04-18-12 353 0.017 +/-0.003 10-24-12 328 0.031 +/- 0.004 04-25-12 326 0.020 +/- 0.003 10-31-12 377 0.028 +/- 0.003 05-02-12 329 0.024 +/- 0.004 11-07-12 382 0.030 +/- 0.003 05-09-12 375 0.015 +/- 0.003 11-14-12 378 0.039 +/- 0.004 05-16-12 375 0.018 +/- 0.003 11-21-12 385 0.083 +/- 0.005 05-23-12 411 0.024 +/- 0.003 11-28-12 348 0.037 +/- 0.004 05-30-12 381 0.013 +/- 0.003 12-05-12 353 0.084 +/- 0.005 06-06-12 378 0.019 +/- 0.003 12-12-12 327 0.047 +/- 0.004 06-13-12 404 0.018 +/- 0.003 12-19-12 350 0.058 +/- 0.004 06-20-12 405 0.020 +/- 0.003 12-27-12 403 0.045 +/- 0.004 06-27-12 358 NOb 01-02-13 281 0.083 +/- 0.006 07-03-12 301 0.028 +/- 0.004 2nd Quarter Mean +/- s.d. 0.019 +/- 0.004 4th Quarter Mean+/- s.d. 0.048 +/- 0.022 Cumulative Average 0.031 Previous Annual Avera~e 0.028 3
a lodine-131 concentrations are< 0.03 pCi!m unless otherwise noted.
b NO= No Data; see Table 2.0, Listing of Missed Samples.
3-1
MONTICELLO Table 4. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 a Location: M-3 3
Units: pCi/m Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected {m") Gross Beta Collected {m") Gross Beta Required LLD 0.010 0.010 01-04-12 328 0.033 +/- 0.003 07-11-12 441 0.019 +/- 0.003 01-11-12 324 0.028 +/- 0.003 07-18-12 NOb 01-18-12 294 0.042 +/- 0.004 07-25-12 353 0.030 +/- 0.003 01-25-12 324 0.046 +/- 0.004 08-01-12 349 0.022 +/- 0.003 02-01-12 324 0.033 +/- 0.003 08-07-12 328 0.020 +/- 0.003 02-08-12 351 0.027 +/- 0.003 08-14-12 359 0.014 +/- 0.003 02-15-12 327 0.032 +/- 0.003 08-21-12 350 0.018 +/- 0.003 02-22-12 293 0.038 +/- 0.004 08-28-12 354 0.028 +/- 0.003 02-29-12 298 0.037 +/- 0.004 09-05-12 402 0.034 +/- 0.003 03-07-12 266 0.038 +/- 0.004 09-11-12 278 0.020 +/- 0.004 368 +/- 09-19-12 374 0.023 +/- 0.003 03-21-12 277 0.021 +/- 0.004 09-26-12 324 0.017 +/- 0.003 03-28-12 320 0.015 +/- 0.003 10-03-12 235 0.046 +/- 0.005 1st Quarter Mean +/- s.d. 0.032 +/- 0.008 3rd Quarter Mean +/- s.d. 0.024 +/- 0.009 04-04-12 324 0.014 +/- 0.003 10-10-12 351 0.023 +/- 0.003 04-11-12 328 0.017 +/- 0.003 10-17-12 298 0.040 +/- 0.004 04-18-12 324 0.017 +/- 0.003 10-24-12 359 0.026 +/- 0.003 04-25-12 324 0.018 +/- 0.003 10-31-12 350 0.029 +/- 0.003 05-02-12 357 0.021 +/- 0.003 11-07-12 355 0.031 +/- 0.003 05-09-12 NOb 11-14-12 351 0.039 +/- 0.004 05-16-12 378 0.019 +/- 0.003 11-21-12 357 0.075 +/- 0.005 05-23-12 371 0.023 +/- 0.003 11-28-12 348 0.037 +/- 0.004 05-30-12 354 0.011 +/- 0.003 12-05-12 353 0.081 +/- 0.005 06-06-12 439 0.014 +/- 0.002 12-12-12 327 0.049 +/- 0.004 06-13-12 379 0.023 +/- 0.003 12-19-12 350 0.062 +/- 0.004 06-20-12 385 0.021 +/- 0.003 12-27-12 372 0.055 +/- 0.004 06-27-12 354 NOb 01-02-13 281 0.082 +/- 0.006 07-03-12 300 0.029 +/- 0.004 2nd Quarter Mean +/- s.d. 0.019 +/- 0.005 4th Quarter Mean +/- s.d. 0.048 +/- 0.021 Cumulative Average 0.031 Previous Annual Average 0.029 3
a lodine-131 concentrations are< 0.03 pCi/m unless otherwise noted.
b NO= No Data; see Table 2.0, Listing of Missed Samples.
4-1
MONTICELLO Table 5. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 a.
Location: M-4 3
Units: pCi/m Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (m3) Gross Beta Collected (m3) Gross Beta Required LLD 0.010 0.010 01-04-12 303 0.037 +/- 0.004 07-11-12 406 0.021 +/- 0.003 01-11-12 325 0.026 +/- 0.003 07-18-12 320 0.044 +/- 0.004 01-18-12 272 0.041 +/- 0.004 07-25-12 354 0.025 +/- 0.003 01-25-12 326 0.049 +/- 0.004 08-01-12 350 0.022 +/- 0.003 02-01-12 298 0.035 +/- 0.004 08-07-12 327 0.024 +/- 0.003 02-08-12 323 0.029 +/- 0.003 08-14-12 358 0.016 +/- 0.003 02-15-12 302 0.034 +/- 0.004 08-21-12 320 0.020 +/- 0.003 02-22-12 297 0.041 +/- 0.004 08-28-12 354 0.036 +/- 0.004 02-29-12 304 0.037 +/- 0.004 09-05-12 400 0.040 +/- 0.004 03-07-12 292 0.036 +/- 0.004 09-11-12 303 0.023 +/- 0.003 03-15-12 340 0.034 +/- 0.004 09-19-12 405 0.027 +/- 0.003 03-21-12 280 0.021 +/- 0.004 09-26-12 352 0.013 +/- 0.003 03-28-12 295 0.017 +/- 0.003 10-03-12 352 0.037 +/- 0.004 1st Quarter Mean +/- s.d. 0.034 +/- 0.009 3rd Quarter Mean +/- s.d. 0.027 +/- 0.010 04-04-12 326 0.014 +/- 0.003 10-10-12 352 0.016 +/- 0.003 04-11-12 302 0.018 +/- 0.003 10-17-12 329 0.040 +/- 0.004 04-18-12 326 0.020 +/- 0.003 10-24-12 355 0.032 +/- 0.004 04-25-12 298 0.017 +/- 0.003 10-31-12 350 0.030 +/- 0.003 05-02-12 328 0.024 +/- 0.004 11-07-12 355 0.031 +/- 0.003 05-09-12 320 0.016 +/- 0.003 11-14-12 351 0.041 +/- 0.004 05-16-12 319 0.020 +/- 0.003 11-21-12 342 0.082 +/- 0.005 05-23-12 297 0.031 +/- 0.004 11-28-12 349 0.038 +/- 0.004 05-30-12 NOb 12-05-12 353 0.084 +/- 0.005 06-06-12 352 0.019 +/- 0.003 12-12-12 327 0.051 +/- 0.004 06-13-12 379 0.019 +/- 0.003 12-19-12 350 0.063 +/- 0.004 06-20-12 386 0.018 +/- 0.003 12-27-12 403 0.053 +/- 0.004 06-27-12 381 0.018 +/- 0.003 01-02-13 281 0.087 +/- 0.006 07-03-12 303 0.026 +/- 0.004 2nd Quarter Mean +/- s.d. 0.020 +/- 0.005 4th Quarter Mean +/- s.d. 0.050 +/- 0.023 Cumulative Average 0.033 Previous Annual Average 0.030 a lodine-131 concentrations are< 0.03 pCi/m 3 unless otherwise noted.
b ND = No Data; see Table 2.0, Listing of Missed Samples.
5-1
MONTICELLO Table 6. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a Location: M-5 Units: pCi/m 3 Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (mo) Gross Beta Collected (m") Gross Beta Required LLD 0.010 0.010 01-04-12 298 0.032 +/- 0.004 07-11-12 406 0.032 +/- 0.003 01-11-12 323 0.026 +/- 0.003 07-18-12 NDb 01-18-12 296 0.036 +/- 0.004 07-25-12 354 0.032 +/- 0.003 01-25-12 294 0.050 +/- 0.004 08-01-12 351 0.022 +/- 0.003 02-01-12 293 0.033 +/- 0.004 08-07-12 326 0.023 +/- 0.003 02-08-12 322 0.030 +/- 0.003 08-14-12 358 0.019 +/- 0.003 02-15-12 327 0.033 +/- 0.004 08-21-12 350 0.017 +/- 0.003 02-22-12 322 0.035 +/- 0.004 08-28-12 355 0.038 +/- 0.004 02-29-12 300 0.038 +/- 0.004 09-05-12 367 0.037 +/- 0.004 03-07-12 317 0.036 +/- 0.004 09-11-12 278 0.020 +/- 0.004 0.033 +/- 09-1 2 405 0.023 +/- 0.003 03-21-12 279 0.022 +/- 0.004 09-26-12 323 0.017 +/- 0.003 03-28-12 320 0.018 +/- 0.003 10-03-12 353 0.036 +/- 0.003 1st Quarter Mean +/- s.d. 0.033 +/- 0.008 3rd Quarter Mean+/- s.d. 0.026 +/- 0.008 04-04-12 324 0.013 +/- 0.003 10-10-12 352 0.017 +/- 0.003 04-11-12 327 0.021 +/- 0.003 10-17-12 297 0.046 +/- 0.004 04-18-12 353 0.021 +/- 0.003 10-24-12 349 0.028 +/- 0.003 04-25-12 324 0.021 +/- 0.003 10-31-12 357 0.029 +/- 0.003 05-02-12 355 0.024 +/- 0.003 11-07-12 355 0.031 +/- 0.003 05-09-12 408 0.014 +/- 0.002 11-14-12 366 0.038 +/- 0.004 05-16-12 434 0.018 +/- 0.003 11-21-12 326 0.077 +/- 0.005 05-23-12 445 0.026 +/- 0.003 11-28-12 350 0.040 +/- 0.004 05-30-12 442 0.016 +/- 0.003 12-05-12 353 0.071 +/- 0.005 06-06-12 499 0.021 +/- 0.002 12-12-12 325 0.051 +/- 0.004 06-13-12 496 0.022 +/- 0.002 12-19-12 349 0.061 +/- 0.004 06-20-12 477 0.021 +/- 0.002 12-27-12 370 0.056 +/- 0.004 06-27-12 498 0.020 +/- 0.002 01-02-13 279 0.087 +/- 0.006 07-03-12 454 0.027 +/- 0.003 2nd Quarter Mean +/- s.d. 0.020 +/- 0.004 4th Quarter Mean +/- s.d. 0.049 +/- 0.021 Cumulative Average 0.032 Previous Annual Average 0.027 3
a lodine-131 concentrations are< 0.03 pCi/m unless otherwise noted.
b ND =No Data; see Table 2.0, Listing of Missed Samples.
6-1
MONTICELLO Table 7. Airborne particulate data, gross beta analyses, monthly averages, minima and maxima.
January April Location Average Minima Maxima Location Average Minima Maxima Control 0.036 0.028 0.044 Control 0.019 0.015 0.022 M-1 0.036 0.028 0.044 M-1 0.019 0.015 0.022 Indicators 0.036 0.026 0.050 Indicators 0.019 0.013 0.024 M-2 0.034 0.026 0.044 M-2 0.019 0.013 0.024 M-3 0.036 0.028 0.046 M-3 0.017 0.014 0.021 M-4 0.038 0.026 0.049 M-4 0.019 0.014 0.024 M-5 0.035 0.026 0.050 M-5 0.020 0.013 0.024 February Location Minima Maxima Location Minima Maxima Control 0.032 0.025 0.036 Control 0.017 0.011 0.026 M-1 0.032 0.025 0.036 M-1 0.017 0.011 0.026 Indicators 0.034 0.027 0.041 Indicators 0.019 0.011 0.031 M-2 0.031 0.029 0.033 M-2 0.017 0.013 0.024 M-3 0.034 0.027 0.038 M-3 0.018 0.011 0.023 M-4 0.035 0.029 0.041 M-4 0.022 0.016 0.031 M-5 0.034 0.030 0.038 M-5 0.018 0.014 0.026 March June Location Average Minima Maxima Location Average Minima Maxima Control 0.026 0.016 0.033 Control 0.020 0.018 0.022 M-1 0.026 0.016 0.033 M-1 0.020 0.018 0.022 Indicators 0.027 0.015 0.038 Indicators 0.021 0.014 0.029 M-2 0.026 0.018 0.034 M-2 0.021 0.018 0.028 M-3 0.026 0.015 0.038 M-3 0.022 0.014 0.029 M-4 0.027 0.017 0.036 M-4 0.020 0.018 0.026 M-5 0.027 0.018 0.036 M-5 0.022 0.020 0.027 Note: unless otherwise specified, samples collected on the first, second or third day of the month are grouped with data of the previous month.
7-1
MONTICELLO Table 7. Airborne particulate data, gross beta analyses, monthly averages, minima and maxima.
July October Location Average Minima Maxima Location Average Minima Maxima Control 0.026 0.020 0.036 Control 0.027 0.016 0.036 M-1 0.026 0.020 0.036 M-1 0.027 0.016 0.036 Indicators 0.027 0.019 0.044 Indicators 0.030 0.016 0.046 M-2 0.027 0.023 0.034 M-2 0.030 0.020 0.042 M-3 0.024 0.019 0.030 M-3 0.029 0.023 0.040 M-4 0.028 0.021 0.044 M-4 0.030 0.016 0.040 M-5 0.029 0.022 0.032 M-5 0.030 0.017 0.046 November Location Maxima Location Minima Control Control 0.047 0.031 0.084 M-1 0.025 0.018 0.038 0.047 0.031 0.084 Indicators 0.023 0.014 0.039 Indicators 0.048 0.030 0.083 M-2 0.025 0.015 0.039 M-2 0.051 0.030 0.083 M-3 0.020 0.014 0.028 M-3 0.046 0.031 0.075 M-4 0.024 0.016 0.036 M-4 0.048 0.031 0.082 M-5 0.025 0.017 0.038 M-5 0.047 0.031 0.077 September December Location Average Minima Maxima Location Average Minima Maxima Control Control 0.068 0.050 0.097 M-1 0.027 0.016 0.037 M-1 0.068 0.050 0.097 Indicators 0.027 0.013 0.046 Indicators 0.064 0.045 0.087 M-2 0.027 0.016 0.036 M-2 0.058 0.045 0.084 M-3 0.028 0.017 0.046 M-3 0.066 0.049 0.082 M-4 0.028 0.013 0.040 M-4 0.067 0.051 0.087 M-5 0.027 0.017 0.037 M-5 0.065 0.051 0.087 Note: unless otherwise specified, samples collected on the first, second or third day of the month are grouped with data of the previous month.
7-2
MONTICELLO Table 8. Airborne particulates, quarterly composites from each location, analysis for gamma-emitting isotopes.
Activit Cumulative Previous 1st Otr. 2nd Otr. 3rd Otr. 4th Otr. Average Average M-1 c Lab Code MAP- 2044 MAP- 4364 MAP- 6452 MAP- 8453 3
Volume(m ) 4258 4944 4968 4550 Be-7 0.064 +/- 0.014 0.094 +/- 0.012 0.086 +/- 0.012 0.041 +/- 0.012 0.064 0.065 Mn-54 < 0.0006 < 0.0007 < 0.0003 < 0.0003 < 0.0007 < 0.0009 Co-58 < 0.0003 < 0.0007 < 0.0004 < 0.0004 < 0.0007 < 0.0009 Co-60 < 0.0004 < 0.0003 < 0.0009 < 0.0007 < 0.0009 < 0.0008 Zn-65 < 0.0005 < 0.0009 < 0.0005 < 0.0006 < 0.0009 < 0.0010 Zr-Nb-95 < 0.0006 < 0.0011 < 0.0007 < 0.0005 < 0.0011 < 0.0014 Ru-103 < 0.0007 < 0.0010 < 0.0007 < 0.0008 < 0.0010 < 0.0011 Ru-106 < 0.0056 < 0.0048 < 0.0028 < 0.0043 < 0.0056 < 0.0079 Cs-134 < 0.0005 < 0.0006 < 0.0004 < 0.0008 < 0.0006 < 0.0008 Cs-137 < 0.0004 < 0.0008 < 0.0004 < 0.0005 < 0.0008 < 0.0009 Ba-La-140 < 0.0011 < 0.0010 < 0.0010 < 0.0015 < 0.0011 < 0.0034 Ce-141 0.0008 < 0.0009 < 0.0014 < 0.0009 < 0.0014 < 0.0017 Ce-144 < 0.0026 < 0.0037 < 0.0032 < 0.0032 < 0.0037 < 0.0050 M-2 Lab Code MAP- 2045 MAP- 4365 MAP- 6453 MAP- 8454 3
Volume(m ) 4275 5050 4573 4567 Be-7 0.060 +/- 0.009 0.076 +/- 0.012 0.080 +/- 0.010 0.053 +/- 0.010 0.064 0.063 Mn-54 < 0.0004 < 0.0004 < 0.0006 < 0.0003 < 0.0006 < 0.0009 Co-58 < 0.0006 < 0.0003 < 0.0004 < 0.0007 < 0.0006 < 0.0009 Co-60 < 0.0003 < 0.0003 < 0.0005 < 0.0006 < 0.0005 < 0.0008 Zn-65 < 0.0008 < 0.0005 < 0.0007 < 0.0008 < 0.0008 < 0.0010 Zr-Nb-95 < 0.0005 < 0.0004 < 0.0007 < 0.0007 < 0.0007 < 0.0014 Ru-103 < 0.0009 < 0.0005 < 0.0007 < 0.0007 < 0.0009 < 0.0011 Ru-106 < 0.0056 < 0.0050 < 0.0029 < 0.0070 < 0.0056 < 0.0079 Cs-134 < 0.0004 < 0.0005 < 0.0007 < 0.0004 < 0.0007 < 0.0008 Cs-137 < 0.0006 < 0.0005 < 0.0005 < 0.0004 < 0.0006 < 0.0009 Ba-La-140 < 0.0009 < 0.0012 < 0.0007 < 0.0015 < 0.0012 < 0.0034 Ce-141 < 0.0012 < 0.0011 < 0.0011 < 0.0013 < 0.0012 < 0.0017 Ce-144 < 0.0019 < 0.0037 < 0.0040 < 0.0031 < 0.0040 < 0.0050 8-1
MONTICELLO Table 8. Airborne particulates, quarterly composites from each location, analysis for gamma-emitting isotopes.
Cumulative Previous 1st Qtr. 2nd Qtr. 3rd Qtr. 4th Qtr. Average Average M-3 Lab Code MAP- 2046 MAP- 4366 MAP- 6454 MAP- 8456 3
Volume(m ) 4094 4617 4240 4451 Be-7 0.064 +/- 0.012 0.076 +/- 0.013 0.089 +/- 0.011 0.042 +/- 0.010 0.065 0.070 Mn-54 < 0.0005 < 0.0007 < 0.0004 < 0.0004 < 0.0007 < 0.0009 Co-58 < 0.0004 < 0.0005 < 0.0006 < 0.0003 < 0.0006 < 0.0009 Co-60 < 0.0003 < 0.0007 < 0.0002 < 0.0005 < 0.0007 < 0.0008 Zn-65 < 0.0006 < 0.0010 < 0.0004 < 0.0006 < 0.0010 < 0.0010 Zr-Nb-95 < 0.0008 < 0.0006 < 0.0004 < 0.0008 < 0.0008 < 0.0014 Ru-103 < 0.0006 0.0009 0.0006 0.001 0.0009 Ru-106 < 0.0057 < 0.0057 < 0.0037 < 0.0030 < 0.0057 < 0.0079 Cs-134 < 0.0005 < 0.0008 < 0.0004 < 0.0006 < 0.0008 < 0.0008 Cs-137 < 0.0006 < 0.0006 < 0.0006 < 0.0007 < 0.0006 < 0.0009 Ba-La-140 < 0.0009 < 0.0018 < 0.0008 < 0.0017 < 0.0018 < 0.0034 Ce-141 < 0.0010 < 0.0013 < 0.0008 < 0.0010 < 0.0013 < 0.0017 Ce-144 < 0.0036 < 0.0034 < 0.0031 < 0.0044 < 0.0036 < 0.0050 M-4 Lab Code MAP- 2047 MAP- 4367 MAP- 6455 MAP- 8457 3
Volume(m ) 3958 4580 4600 4496 Be-7 0.068 +/- 0.012 0.091 +/- 0.013 0.090 +/- 0.013 0.046 +/- 0.009 0.068 0.069 Mn-54 < 0.0006 < 0.0007 < 0.0005 < 0.0005 < 0.0007 < 0.0009 Co-58 < 0.0005 < 0.0005 < 0.0005 < 0.0004 < 0.0005 < 0.0009 Co-60 < 0.0004 < 0.0004 < 0.0006 < 0.0003 < 0.0006 < 0.0008 Zn-65 < 0.0008 < 0.0010 < 0.0006 < 0.0005 < 0.0010 < 0.0010 Zr-Nb-95 < 0.0008 < 0.0010 < 0.0006 < 0.0006 < 0.0010 < 0.0014 Ru-103 < 0.0006 < 0.0011 < 0.0006 < 0.0007 < 0.0011 < 0.0011 Ru-106 < 0.0047 < 0.0067 < 0.0038 < 0.0037 < 0.0067 < 0.0079 Cs-134 < 0.0008 < 0.0006 < 0.0005 < 0.0004 < 0.0008 < 0.0008 Cs-137 < 0.0008 < 0.0006 < 0.0007 < 0.0007 < 0.0008 < 0.0009 Ba-La-140 < 0.0016 < 0.0022 < 0.0010 < 0.0012 < 0.0022 < 0.0034 Ce-141 < 0.0009 < 0.0012 < 0.0009 < 0.0011 < 0.0012 < 0.0017 Ce-144 < 0.0022 < 0.0039 < 0.0045 < 0.0039 < 0.0045 < 0.0050 8-2
MONTICELLO Table 8. Airborne particulates, quarterly composites from each location, analysis for gamma-emitting isotopes.
Cumulative Previous 1st Qtr. 2nd Qtr. 3rd Qtr. 4th Qtr. Average Average M-5 Lab Code MAP- 2048 MAP- 4368 MAP- 6456 MAP- 8458 3
Volume(m ) 4060 5836 4309 4427 Be-7 0.068 +/- 0.012 0.100 +/- 0.014 0.093 +/- 0.012 0.042 +/- 0.012 0.068 0.064 Mn-54 < 0.0007 < 0.0007 < 0.0009 < 0.0008 < 0.0009 < 0.0009 Co-58 < 0.0007 < 0.0005 < 0.0006 < 0.0006 < 0.0007 < 0.0009 Co-60 < 0.0007 < 0.0004 < 0.0007 < 0.0005 < 0.0007 < 0.0008 Zn-65 < 0.0013 < 0.0007 < 0.0015 < 0.0023 < 0.0015 < 0.0010 Zr-Nb-95 < 0.0013 < 0.0008 < 0.0011 < 0.0020 < 0.0013 < 0.0014 Ru-103 < 0.0009 < 0.0007 < 0.0008 < 0.0012 < 0.0009 < 0.0011 Ru-106 < 0.0068 < 0.0043 < 0.0058 < 0.0077 < 0.0068 < 0.0079 Cs-134 < 0.0005 < 0.0004 < 0.0007 < 0.0008 < 0.0007 < 0.0008 Cs-137 < 0.0006 < 0.0006 < 0.0007 < 0.0006 < 0.0007 < 0.0009 Ba-La-140 < 0.0013 < 0.0013 < 0.0012 < 0.0016 < 0.0013 < 0.0034 Ce-141 < 0.0012 < 0.0013 < 0.0013 < 0.0014 < 0.0013 < 0.0017 Ce-144 < 0.0030 < 0.0025 < 0.0038 < 0.0041 < 0.0038 < 0.0050 8-3
MONTICELLO Table 9. Milk, analysis for iodine-131 and gamma-emitting isotopes.
Collection: Monthly- November through April.
Biweekly- May through October.
Date Lab Concentration (pCi/L}
Location Collected Code 1-131 K-40 Cs-134 Cs-137 Ba-La-140 8
Kitzman 01-31-12 NS M-16 04-11-12 MMI -2011 < 0.5 1436 +/- 110 <5 <5 <5 05-09-12 MMI -2723 < 0.5 1579 +/- 127 <5 <5 <5 05-22-12 MMI -3088 < 0.5 1898 +/- 114 <5 <5 <5 06-06-12 MMI -3481 < 0.5 1899 +/- 115 <5 <5 <5 06-20-12 MMI -3727 < 0.5 1982 +/- 127 <5 <5 <5 07-03-12 MMI -3960 < 0.5 1963 +/- 82 <5 <5 <5 07-16-12 MMI -4266 < 0.5 1881 +/- 138 <5 <5 <5 08-01-12 MMI -4785 < 0.5 1854 +/- 106 <5 <5 <5 08-15-12 MMI -5094 < 0.5 1818 +/- 127 <5 <5 <5 08-29-12 MMI -5428 < 0.5 1798 +/- 123 <5 <5 <5 09-12-12 MMI -5724 < 0.5 1874 +/- 110 <5 <5 <5 09-27-12 MMI -6051 < 0.5 1944 +/- 118 <5 <5 <5 10-10-12 MMI -6329 < 0.5 1854 +/- 97 <5 <5 <5 10-24-12 MMI -6908 < 0.5 1765 +/- 127 <5 <5 <5 11-07-12 MMI -7168 < 0.5 1697 +/- 100 <5 <5 <5 2-31 2 NS Cumulative Average < 0.5 1816 <5 <5 <5 Previous Annual Average < 0.5 1818 <5 <5 <5 8
Greniger (C) 01-31-12 NS M-17C 04-11-12 MMI -2012 < 0.5 1929 +/- 127 <5 <5 <5 05-09-12 MMI -2724 < 0.5 2082 +/- 136 <5 <5 <5 05-23-12 MMI -3089 < 0.5 1768+/-110 <5 <5 <5 06-06-12 MMI -3482 < 0.5 1945 +/- 145 <5 <5 <5 06-20-12 MMI -3728 < 0.5 1736 +/- 92 <5 <5 <5 07-03-12 MMI -3961 < 0.5 1553 +/- 113 <5 <5 <5 07-16-12 MMI -4267 < 0.5 1692 +/- 77 <5 <5 <5 08-02-12 MMI -4836 < 0.5 1687 +/- 121 <5 <5 <5 08-14-12 MMI -5057 < 0.5 1619 +/- 128 <5 <5 <5 08-29-12 MMI -5429 < 0.5 1909 +/- 112 <5 <5 <5 09-12-12 MMI -5725 < 0.5 1866 +/- 106 <5 <5 <5 09-27-12 MMI -6052 < 0.5 1820 +/- 116 <5 <5 <5 10-10-12 MMI -6330 < 0.5 1750 +/- 122 <5 <5 <5 10-24-12 MMI -6909 < 0.5 1512 +/- 88 <5 <5 <5 11-07-12 MMI -7169 < 0.5 1704 +/- 99 <5 <5 <5 8
12-31-12 NS Cumulative Average < 0.5 1771 <5 <5 <5 Previous Annual Average 1.5 1821 <5 <5 <5 a NS =No Sample; see Table 2.0, Listing of Missed Samples.
9-1
Table 9A. Pasture grass, vegetation, analysis for gamma-emitting isotopes.
Collection: 3x per year Previous Sample Description and Concentration (pCi/g wet) Annual Annual Location: M-41 (Training Center)
Date Collected 07-16-12 08-14-12 09-19-12 Lab Code MVE- 4268 MVE- 5091 MVE- 5925 Mn-54 < 0.005 < 0.009 < 0.005 < 0.009 <0.015 Fe-59 < 0.027 < 0.016 < O.Q18 < 0.027 < 0.040 Co-58 < 0.006 < 0.008 < 0.006 < 0.008 < 0.013 Co-60 < 0.010 < 0.009 < 0.011 < 0.011 < 0.013 Zn-65 < 0.021 < 0.020 < 0.025 < 0.025 < 0.036 Nb-95 < 0.014 < 0.012 < 0.010 < 0.014 < 0.018 1-131 < 0.025 < 0.023 < 0.044 < 0.044 < 0.018 Cs-134 < 0.010 < 0.008 < 0.009 < 0.010 < 0.014 Cs-137 < 0.007 < 0.010 < 0.009 < 0.010 < 0.017 Location:
9-12 Lab Code MVE- 4269 MVE- 5092 MVE- 5926 Mn-54 < 0.009 < 0.011 < 0.011 < 0.011 < 0.017 Fe-59 < 0.022 < 0.023 < 0.022 < 0.023 < 0.038 Co-58 < 0.009 < 0.010 < 0.007 < 0.010 < 0.015 Co-60 < 0.010 < 0.008 < 0.005 < 0.010 < 0.019 Zn-65 < 0.022 < 0.013 < O.Q18 < 0.022 < 0.026 Nb-95 < 0.010 < 0.011 < 0.009 < 0.011 < 0.015 1-131 < 0.025 < 0.021 < 0.034 < 0.034 < 0.022 Cs-134 < 0.008 < 0.008 < 0.009 < 0.009 < 0.014 Cs-137 < 0.012 < 0.007 < 0.014 < 0.014 < 0.020 Location: M-43 (lmholte Farm, Control)
Date Collected 07-16-12 08-14-12 09-19-12 Lab Code MVE- 4270 MVE- 5093 MVE- 5927 Mn-54 < 0.007 < 0.010 < 0.009 <0.010 <0.016 Fe-59 < 0.031 < 0.012 < 0.016 < 0.031 < 0.038 Co-58 < 0.007 < 0.008 < 0.008 < 0.008 < 0.012 Co-60 < 0.011 < 0.004 < 0.012 < 0.012 < 0.011 Zn-65 < 0.030 < 0.018 < 0.015 < 0.030 < 0.020 Nb-95 < 0.011 < 0.011 < 0.011 < 0.011 < 0.017 1-131 < 0.021 < 0.017 < 0.031 < 0.031 < 0.027 Cs-134 < 0.009 < 0.008 < 0.006 < 0.009 <0.013 Cs-137 < 0.010 < 0.009 < 0.013 < 0.013 < 0.013 9A-1
MONTICELLO Table 10. River water, analysis of monthly composites for gamma-emitting isotopes.
Location: M-8 (C)
Collection: Weekly Sample Description and Concentration (pCi/L)
Period Collected January February March April May Lab Code MSW-716 MSW-1444 MSW-1950 MSW-2708 MSW-3535 Mn-54 < 10 < 10 < 10 < 10 < 10 Fe-59 < 30 < 30 < 30 < 30 < 30 Co-58 < 10 < 10 < 10 < 10 < 10 Co-60 < 10 < 10 < 10 < 10 < 10 Zn-65 < 30 < 30 < 30 < 30 < 30 Zr-Nb-95 < 15 < 15 < 15 < 15 < 15 Cs-134 < 10 < 10 < 10 < 10 < 10 Cs-137 < 10 < 10 < 10 < 10 < 10 Ba-La-140 < 15 < 15 < 15 < 15 < 15 Ce-144 < 10 < 15 < 13 < 11 < 19 Period Collected June July August September October Mn-54 < 10 <10 < 10 < 10 < 10 Fe-59 < 30 < 30 < 30 < 30 < 30 Co-58 < 10 < 10 < 10 < 10 < 10 Co-60 < 10 < 10 < 10 < 10 < 10 Zn-65 < 30 < 30 < 30 < 30 < 30 Zr-Nb-95 < 15 < 15 < 15 < 15 < 15 Cs-134 < 10 < 10 < 10 < 10 < 10 Cs-137 < 10 < 10 < 10 < 10 < 10 Ba-La-140 < 15 < 15 < 15 < 15 < 15 Ce-144 < 10 <18 < 16 < 21 < 23 Previous Period Collected November December Cumulative Annual Lab Code MSW-8012 MSW-8368 Average Average Mn-54 < 10 < 10 < 10 < 10 Fe-59 < 30 < 30 < 30 < 30 Co-58 < 10 < 10 < 10 < 10 Co-60 < 10 < 10 < 10 < 10 Zn-65 < 30 < 30 < 30 < 30 Zr-Nb-95 < 15 < 15 < 15 < 15 Cs-134 < 10 < 10 < 10 < 10 Cs-137 < 10 < 10 < 10 < 10 Ba-La-140 < 15 < 15 < 15 < 15 Ce-144 < 24 < 13 < 24 < 26 a Composite of three samples for month; see Table 2.0, Listing of Missed Samples.
b Composite of two samples for month; see Table 2.0, Listing of Missed Samples.
c Only one sample for December collected 12-05-12; water frozen remainder of month.
10-1
MONTICELLO Table 10. River water, analysis of monthly composites for gamma-emitting isotopes.
Location: M-9 Collection: Weekly Sample Description and Concentration (pCi/L)
Period Collected January February March April May Lab Code MSW-717 MSW-1445 MSW-1951 MSW-2709 MSW-3536 Mn-54 < 10 < 10 < 10 < 10 < 10 Fe-59 < 30 < 30 < 30 < 30 < 30 Co-58 < 10 < 10 < 10 < 10 < 10 Co-60 < 10 < 10 < 10 < 10 < 10 Zn-65 < 30 < 30 < 30 < 30 < 30 Zr-Nb-95 < 15 < 15 < 15 < 15 < 15 Cs-134 < 10 < 10 < 10 < 10 < 10 Cs-137 < 10 < 10 < 10 < 10 < 10 Ba-La-140 < 15 < 15 < 15 < 15 < 15 Ce-144 < 20 < 14 < 17 < 15 < 21 Period Collected June July August September October Lab Code MSW-4388 MSW-4885 MSW-5869 MSW-6738 MSW-7480 Mn-54 < 10 < 10 < 10 < 10 < 10 Fe-59 < 30 < 30 < 30 < 30 < 30 Co-58 < 10 < 10 <10 < 10 < 10 Co-60 < 10 < 10 < 10 < 10 < 10 Zn-65 < 30 < 30 < 30 < 30 < 30 Zr-Nb-95 < 15 < 15 < 15 < 15 < 15 Cs-134 < 10 < 10 < 10 < 10 < 10 Cs-137 < 10 < 10 < 10 < 10 < 10 Ba-La-140 < 15 < 15 < 15 < 15 < 15 Ce-144 < 12 <9 < 30 < 31 < 25 Previous Period Collected November December Cumulative Annual Lab Code MSW-8014 MSW-8369 Average Average Mn-54 < 10 < 10 < 10 < 10 Fe-59 < 30 < 30 < 30 < 30 Co-58 < 10 < 10 < 10 < 10 Co-60 < 10 < 10 < 10 < 10 Zn-65 < 30 < 30 < 30 < 30 Zr-Nb-95 < 15 < 15 < 15 < 15 Cs-134 < 10 < 10 < 10 < 10 Cs-137 < 10 < 10 < 10 < 10 Ba-La-140 < 15 < 15 < 15 < 15 Ce-144 < 25 < 16 < 31 < 43 10-2
MONTICELLO Table 11. Drinking water, City of Minneapolis, M-14, analysis of monthly composites for gross beta, iodine-131, and gamma-emitting isotopes.
Collection: Weeki~
Sample Description and Concentration (pCi/L)
Period Collected January February March April May Lab Code MDW-616 MDW-1134 MDW-1664 MDW-2639 MDW-3444 Gross beta 3.1+/-0.7 2.2 +/- 0.7 2.0 +/- 0.6 2.2 +/- 1.0 2.7 +/- 0.8 1-131 < 1.0 < 1.0 < 1.0 < 1.0 < 1.0 Mn-54 < 10 < 10 < 10 < 10 < 10 Fe-59 < 30 < 30 < 30 < 30 < 30 Co-58 < 10 < 10 < 10 < 10 < 10 Co-60 < 10 < 10 < 10 < 10 < 10 Zn-65 < 30 < 30 < 30 < 30 < 30 Zr-Nb-95 < 15 < 15 < 15 < 15 < 15 Cs-134 < 10 < 10 < 10 < 10 < 10 Cs-137 < 10 < 10 < 10 < 10 < 10 Ba-La-140 < 15 < 15 < 15 < 15 < 15 Ce-144 < 17 < 22 < 26 < 18 < 22 Period Collected June July August September October Lab Code MDW-4120 MDW-5038 MDW-5661 MDW-6130 MDW-7229 Gross beta 2.0 +/- 0.8 2.5 +/- 1.0 3.1 +/- 1.8 2.1 +/- 1.0 < 0.9 1-131 < 1.0 < 1.0 < 1.0 < 1.0 < 1.0 Mn-54 < 10 < 10 < 10 < 10 < 10 Fe-59 < 30 < 30 < 30 < 30 < 30 Co-58 < 10 < 10 < 10 < 10 < 10 Co-60 < 10 < 10 < 10 < 10 < 10 Zn-65 < 30 < 30 < 30 < 30 < 30 Zr-Nb-95 < 15 < 15 < 15 < 15 < 15 Cs-134 < 10 < 10 < 10 < 10 < 10 Cs-137 < 10 < 10 < 10 < 10 < 10 Ba-La-140 < 15 < 15 < 15 < 15 < 15 Ce-144 < 15 < 26 < 21 < 36 < 22 Period Collected November December Cumulative Previous Lab Code MDW-7897 MDW-8367 Average Average Gross beta 2.8 +/- 1.0 2.2 +/- 0.8 2.4 2.2 1-131 < 1.0 < 1.0 < 1.0 < 1.0 Mn-54 < 10 < 10 < 10 < 10 Fe-59 < 30 < 30 < 30 < 30 Co-58 < 10 < 10 < 10 < 10 Co-60 < 10 < 10 < 10 < 10 Zn-65 < 30 < 30 < 30 < 30 Zr-Nb-95 < 15 < 15 < 15 < 15 Cs-134 < 10 < 10 < 10 < 10 Cs-137 < 10 < 10 < 10 < 10 Ba-La-140 < 15 < 15 < 15 < 15 Ce-144 < 22 < 18 < 36 < 27 11-1
MONTICELLO Table 12. River water and drinking water, analysis of quarterly composites for tritium.
Collection: Quarterly composites of weekly collections.
Sample Type, Location and Concentration (pCi/L)
Collection Period Lab Code H-3 River Water Upstream, M-8 (C) 1st Quarter MSW - 1952 < 500 < 143 2nd Quarter MSW- 4381 < 500 < 152 3rd Quarter MSW- 6732 < 500 < 152 4th Quarter MSW- 8375 < 500 < 141 Cumulative Average < 500 < 147 Previous Annual Average < 500 < 145 River Water Downstream, M-9 1st Quarter MSW-1953 < 500 < 143 2nd Quarter MSW- 4382 < 500 < 152 3rd Quarter MSW- 6734 < 500 < 152 4th Quarter MSW- 8376 < 500 < 141 Cumulative Average < 500 < 147 Previous Annual Average < 500 < 145 Drinking Water Minneapolis, M-14 1st Quarter MOW- 1954 < 500 < 143 2nd Quarter MOW- 4379 < 500 < 152 3rd Quarter MOW- 6729 < 500 < 152 4th Quarter MOW- 8366 < 500 < 140 Cumulative Average < 500 < 147 Previous Annual Average < 500 < 146 12-1
MONTICELLO Table 13. Well water, analysis for tritium and gamma-emitting isotopes.
Sample Description and Concentration (pCi!L)
L{)
(J)
Date H-3 (J) co 0 L{) .6
'? L{)
6
<0 6 '9 z c
~
(!)
Collected Lab Code (< 500 pCi!L) 1.1... 0 0 N Monticello (M-11) 1/18/2012 MWW-290 < 145 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 21 4/19/2012 MWW-2243 < 150 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 35 7/25/2012 MWW-4601 < 164 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 29 10/17/2012 MWW-6816 < 177 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 46 Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 46 1/18/2012 MWW-291 < 145 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 28 4/18/2012 MWW-2244 < 150 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 15 7/25/2012 MWW-4603 < 164 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 45 10/17/2012 MWW-6818 < 177 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 17 Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 45 Wise (M-27) 1/18/2012 NSa 4/18/2012 MWW-2245 < 150 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 26 7/25/2012 MWW-4604 < 164 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 40 10/17/2012 MWW-6819 < 177 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 40 Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 40 lmholte (M-43) Control 1/18/2012 MWW-292 < 145 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 33 4/18/2012 MWW-2246 < 150 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 29 7/25/2012 MWW-4605 < 164 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 39 10/17/2012 MWW-6820 < 177 <10 <30 <10 <10 <30 <15 <10 <10 <15 <41 Cumulative Averages < 500 < 10 < 30 < 10 < 10 < 30 < 15 < 10 < 10 < 15 < 41 a NS = No Sample, see Table 2.0, Listing of Missed Samples.
13-1
MONTICELLO Table 14. Fish, analysis of edible portions for gamma-emitting isotopes.
Collection: Semiannually Sample Description and Concentration (pCi/g wet) Cumulative Previous Average Average Upstream 1000' M-8 (C)
Date Collected 05-31-12 05-31-12 10-25-12 Lab Code MF- 3258 MF- 3259 MF- 7009 Sample Type Smallmouth Bass Silver Redhorse Mixed composite K-40 3.51 +/- 0.47 3.33 +/- 0.39 3.24 +/- 0.47 3.36 2.98 Mn-54 < 0.018 < 0.009 < 0.011 < 0.018 < 0.014 Fe-59 < 0.055 < 0.031 < 0.045 < 0.055 < 0.021 Co-58 < 0.023 < 0.016 < 0.023 < 0.023 < 0.010 Co-60 < 0.008 < 0.013 < 0.022 < 0.022 < 0.013 Zn-65 < 0.037 < 0.016 < 0.035 < 0.037 < 0.012 Nb-95 < 0.023 < 0.027 < 0.019 < 0.027 < 0.013 Zr-95 < 0.028 < 0.027 < 0.035 < 0.035 < 0.019 Cs-1 0.018 0.012 < O.Q17 < 0.018 < 0.01 Cs-137 < 0.015 < 0.014 < 0.020 < 0.020 < 0.014 Ba-La-140 < 0.034 < 0.020 < 0.067 < 0.067 <0.018 Ce-144 < 0.107 < 0.065 < 0.107 < 0.107 < 0.092 Downstream 1000' M-9 Date Collected 05-31-12 05-31-12 10-25-12 Lab Code MF- 3260 MF- 3261 MF- 7010 Sample Type Smallmouth Bass Silver Redhorse Mixed composite K-40 3.58 +/- 0.41 3.43 +/- 0.41 3.02 +/- 0.34 3.34 3.06 Mn-54 < 0.017 < 0.012 < 0.015 <0.017 <0.017 Fe-59 < 0.037 < 0.034 < 0.052 < 0.052 < 0.033 Co-58 < 0.017 < 0.009 < 0.023 < 0.023 < 0.011 Co-60 < 0.010 < 0.005 < 0.013 < 0.013 < 0.010 Zn-65 < 0.020 < 0.019 < 0.030 < 0.030 < 0.023 Nb-95 < 0.021 < 0.021 < 0.021 < 0.021 < 0.009 Zr-95 < 0.022 < 0.039 < 0.034 < 0.039 < 0.026 Cs-134 < 0.014 < 0.012 < 0.013 < 0.014 < 0.013 Cs-137 < 0.014 < 0.011 < 0.017 < 0.017 < 0.024 Ba-La-140 < 0.043 < 0.025 < 0.032 < 0.043 < 0.021 Ce-144 < 0.081 < 0.084 < 0.100 < 0.100 < 0.082 14-1
MONTICELLO Table 15. Algae or aquatic insects, analysis for gamma-emitting isotopes.
Collection: Semiannually Sample Description and Concentration (pCi/g wet) Cumulative Previous Average Average Upstream 1000' M-8 (C)
Date Collected 09-05-12 Lab Code MBO- 5551 Be-7 < 0.58 < 0.58 < 0.64 K-40 < 1.08 < 1.08 < 1.35 Mn-54 < 0.048 < 0.048 < 0.069 Fe-59 < 0.12 < 0.12 < 0.089 Co-58 < 0.068 < 0.068 < 0.056 Co-60 < 0.052 < 0.052 < 0.034 Zn-65 < 0.097 < 0.097 < 0.13 Zr-Nb-95 < 0.12 < 0.12 < 0.076 Ru-103 < 0.091 < 0.091 < 0.065 06 0.34 < 0.34 < 0.45 Cs-134 < 0.045 < 0.045 < 0.050 Cs-137 < 0.042 < 0.042 < 0.053 Ba-La-140 < 0.39 < 0.39 < 0.17 Ce-144 < 0.30 < 0.30 < 0.24 Downstream 1000' M-9 Date Collected 09-05-12 Lab Code MBO- 5552 Be-7 < 0.48 < 0.48 < 0.33 K-40 < 0.97 < 0.97 < 0.65 Mn-54 < 0.051 < 0.051 < 0.024 Fe-59 < 0.17 < 0.17 < 0.075 Co-58 < 0.072 < 0.072 < 0.036 Co-60 < 0.022 < 0.022 < 0.024 Zn-65 < 0.094 < 0.094 < 0.057 Zr-Nb-95 < 0.086 < 0.086 < 0.044 Ru-103 < 0.053 < 0.053 < 0.051 Ru-106 < 0.39 < 0.39 < 0.31 Cs-134 < 0.046 < 0.046 < 0.036 Cs-137 < 0.055 < 0.055 < 0.040 Ba-La-140 < 0.25 < 0.25 < 0.072 Ce-144 < 0.25 < 0.25 < 0.12 15-1
MONTICELLO Table 16. Edible cultivated (irrigated) crops, analysis for iodine-131 and gamma-emitting isotopes.
Collection: Annually Sample Description and Concentration (pCi/g wet)
Location: Control (Cabbage)
Date Collected Lab Code NDa Mn-54 -
Fe-59 -
Co-58 -
Co-60 -
Zn-65 -
Nb-95 -
I-131 -
Cs-134 -
Cs-137 -
Location: M-27 (Cabbage)
Date Collected Lab Code NDa Mn-54 -
Fe-59 -
Co-58 -
Co-60 -
Zn-65 -
Nb-95 -
I-131 -
Cs-134 -
Cs-137 -
a ND = No data; sample not collected.
16-1
MONTICELLO Table 17. Shoreline (SS) sediments, analysis for gamma-emitting isotopes.
Collection: Semiannually Sample Description and Concentration (pCilg dry) Cumulative Previous Average Average Upstream 1000' M-8 (C)
Date Collected 09-05-12 Lab Code MSS- 5553 Be-7 < 0.18 < 0.18 < 0.20 K-40 10.02 +/- 0.52 10.02 10.50 Mn-54 < 0.013 < 0.013 < 0.014 Fe-59 < 0.031 < 0.031 < 0.040 Co-58 < 0.016 < 0.016 < 0.018 Co-60 < 0.015 < 0.015 < 0.011 Zn-65 < 0.025 < 0.025 < 0.034 Nb-95 < 0.028 < 0.028 < 0.026 Zr-95 < 0.023 < 0.023 < 0.038 Ru-103 < 0.013 < 0.013 < 0.022 Ru-106 < 0.056 < 0.056 < 0.16 Cs-134 < 0.010 < 0.010 < 0.013 Cs-137 < 0.014 < 0.014 < 0.014 Ba-La-140 < 0.044 < 0.044 < 0.064 Ce-144 < 0.10 < 0.10 < 0.11 Downstream 1000' M-9 Date Collected 09-05-12 Lab Code MSS- 5554 Be-7 0.33 +/- 0.19 0.33 < 0.27 K-40 8.85 +/- 0.49 8.85 10.75 Mn-54 < 0.017 < 0.017 < 0.022 Fe-59 < 0.042 < 0.042 < 0.068 Co-58 < 0.019 < 0.019 < 0.021 Co-60 < 0.013 < 0.013 < 0.018 Zn-65 < 0.030 < 0.030 < 0.040 Nb-95 < 0.032 < 0.032 < 0.034 Zr-95 < 0.014 < 0.014 < 0.048 Ru-103 < 0.017 < 0.017 < 0.027 Ru-106 < 0.062 < 0.062 < 0.16 Cs-134 < 0.011 < 0.011 < 0.016 Cs-137 < 0.013 < 0.013 0.065 Ba-La-140 < 0.043 < 0.043 < 0.055 Ce-144 < 0.081 < 0.081 < 0.14 17-1
MONTICELLO Table 17. Shoreline (SS) sediments, analysis for gamma-emitting isotopes (continued}.
Sample Description and Concentration (pCi!g dry) Cumulative Previous Average Average Montissippi Park M-15 Date Collected 09-05-12 Lab Code MSS- 5555 Be-7 1.09 +/- 0.33 1.09 < 0.18 K-40 10.82 +/- 0.63 10.82 9.85 Mn-54 < 0.020 < 0.020 < 0.015 Fe-59 < 0.030 < 0.030 < 0.046 Co-58 < 0.026 < 0.026 < 0.015 Co-60 < 0.016 < 0.016 < 0.013 Zn-65 < 0.035 < 0.035 < 0.042 Nb-95 < 0.026 < 0.026 < 0.038 Zr-95 < 0.020 < 0.020 < 0.039 Ru-103 < 0.027 < 0.027 < 0.018 Ru-106 < 0.14 < 0.14 < 0.117 Cs-134 < 0.014 < 0.014 < 0.013 Cs-137 0.081 +/- 0.022 0.081 0.028 Ba-La-140 < 0.059 < 0.059 < 0.039 Ce-144 < 0.12 < 0.124 < 0.092 17-2
ENCLOSURE 3 CORRECTIONS TO THE 2013 AREOR 1 Page to Follow
L-MT-16-035 Page 1 of 1 Broadleaf vegetation samples were not collected since 2011 due to unavailability; these samples were not included as missed samples, because they were considered to be above and beyond required samples. Since they were included in the Offsite Dose Calculation Manual (ODCM) ODCM-07.01 Table 1, they were required samples for Monticello Nuclear Generating Plant and should have been included as missed samples. The affected pages have been included in their entirety and should replace existing pages (5 and 17 of the main report, and V of the Completed Data Tables), ML14139A025.
ENCLOSURE 3 ATTACHMENT 1 REPLACEMENT PAGES FOR THE 2013 AREOR 3 Pages to Follow
3.3 Program Execution The Program was executed as described in the preceding section with the following exceptions:
(1) Air Particulates / Air Iodine:
M-01, No air particulate / air iodine sample was available from for the week ending January 16, 2013, the sampler failed down due to a faulty toggle switch.
M-01, A partial air particulate / air iodine sample (54 m3) was collected for the week ending May 1, 2013, due to sampler failure. No air particulate / air iodine sample was available for the week ending May 8, 2013, due to sampler failure. The vacuum pump was replaced.
M-02, No air particulate sample was collected for the week ending November 27, 2013, the filter was misaligned in the holder.
(2) Surface Water:
Surface water was not collected at location M-08 for the months of January, February, March and December, 2013, due to unsafe ice conditions.
(3) Well Water:
Well water was not collected at location MW-27 in January, 2013. No water was available from the outside tap.
(4) Drinking Water (M-14):
No sample was available for the January 13, 2013 collection. The sample was damaged in shipment. The drinking water sample for May 17, 2013 was lost during shipping.
No drinking water sample was available November 27, 2013. The sample was missed.
(5) Milk There was no goat milk available from locations M-16 and M-17 in 2013. Goats are no longer milked at location M-16, the herd has been sold.
(6) Broad Leaf Vegetables Broad Leaf Vegetables were not collected in 2013 due to unavailability. The previous Critical Garden ceased to be used and attempts to obtain a sample from the new Critical Garden were unsuccessful.
Deviations from the program are summarized in Table 5.3.
3.4 Program Modifications Milk sampling was dropped from the REMP in 2013. The indicator location M-16, discontinued dairy operations.
Modifications to the Groundwater monitoring program are detailed in Appendix E.
5
Table 5.3. MISSED COLLECTIONS AND ANALYSES All required samples were collected and analyzed as scheduled with the following exceptions:
Collection Reason for not Sample Analysis Location Date or conducting REMP Plans for Preventing Type Period as required Recurrence WW Gamma, H-3 M-014 1/13/2013 Sample damaged in shipment. None required.
AP/AI Beta, I-131 M-01 1/16/2013 Pump found off. Sampler restarted.
SW Gamma M-008 Jan. 2013 Water frozen entire month; None required.
no composite.
WW Gamma, H-3 M-027 1/23/2013 Residence vacant, None required.
water turned off.
SW Gamma M-008 Feb. 2013 Water frozen entire month; None required.
no composite.
SW Gamma M-008 Mar. 2013 Water frozen entire month; None required.
no composite.
SW H-3 M-008 1st Qtr '13 Water frozen entire quarter; None required.
no composite.
AP/AI Beta, I-131 M-01 5/1/2013 Pump found off. Sampler pump replaced.
WW Gamma, H-3 M-014 5/7/2013 Sample damaged in shipment. None required.
AP/AI Beta, I-131 M-01 5/8/2013 Pump failure. Sampler pump replaced.
AP/AI Beta, I-131 M-02 11/27/2013 Filter misaligned in holder; Technician coached on light particulate collected. verification practices.
WW Gamma, H-3 M-014 11/27/2013 No sample taken. Technician coached on proper turnover.
SW Gamma M-008 Dec. 2013 Water frozen entire month; None required.
no composite.
Highest D/Q Samples became unavailable when Attempted to obtain a VE I-131 Garden and At Harvest previous Critical Garden ceased to be sample from new Control used. Critical Garden 17
2.0. LISTING of MISSED SAMPLES All required samples were collected and analyzed as scheduled with the following exceptions:
Collection Reason for not Sample Analysis Location Date or conducting REMP Plans for Preventing Type Period as required Recurrence WW Gamma, H-3 M-014 1/13/2013 Sample damaged in shipment. None required.
AP/AI Beta, I-131 M-01 1/16/2013 Pump found off. Sampler restarted.
SW Gamma M-008 Jan. 2013 Water frozen entire month; None required.
no composite.
WW Gamma, H-3 M-027 1/23/2013 Residence vacant, None required.
water turned off.
SW Gamma M-008 Feb. 2013 Water frozen entire month; None required.
no composite.
SW Gamma M-008 Mar. 2013 Water frozen entire month; None required.
no composite.
SW H-3 M-008 1st Qtr '13 Water frozen entire quarter; None required.
no composite.
AP/AI Beta, I-131 M-01 5/1/2013 Pump found off. Sampler pump replaced.
WW Gamma, H-3 M-014 5/7/2013 Sample damaged in shipment. None required.
AP/AI Beta, I-131 M-01 5/8/2013 Pump failure. Sampler pump replaced.
AP/AI Beta, I-131 M-02 11/27/2013 Filter misaligned in holder; Technician coached on light particulate collected. verification practices.
WW Gamma, H-3 M-014 11/27/2013 No sample taken. Technician coached on proper turnover.
SW Gamma M-008 Dec. 2013 Water frozen entire month; None required.
no composite.
Highest D/Q Samples became unavailable when Attempted to obtain a VE I-131 Garden and At Harvest previous Critical Garden ceased to be sample from new Control used. Critical Garden v
ENCLOSURE 4 CORRECTIONS TO THE 2014 AREOR 1 Page to Follow
L-MT-16-035 Page 1 of 1 Inaccuracies were discovered in the 2014 Annual Radiological Environmental Operating Report, Groundwater Monitoring section (Appendix E). The inaccuracies are being corrected in the attached pages. The affected pages have been included in their entirety and should replace the existing pages, ML15132A628.
ENCLOSURE 4 ATTACHMENT 1 REPLACEMENT PAGES FOR THE 2014 AREOR 6 Pages to Follow
1.0 INTRODUCTION
This appendix to the Radiological Environmental Monitoring Program Annual Report to the United States Nuclear Regulatory Commission summarizes and interprets results of the Ground Water Monitoring Program samples taken at the Monticello Nuclear Plant, Monticello, Minnesota, during the period January - December 2014. This sampling program was established in October of 2006 following the industry initiative on ground water monitoring.
E-2
2.0
SUMMARY
The Ground Water Sampling Program was established following industry events where tritium was discovered in ground water surrounding commercial nuclear facilities. This program is described and the results for 2014 are summarized and discussed.
Program findings for 2014 detected low levels of tritium in monitoring wells located on the plant property. With the exception of monitoring wells MW-9A and MW-13A, tritium measured at or near expected natural background levels. Tritium was detected at a concentration greater than 500 pCi/l in one of four storm water runoff samples collected from storm water outfall sample point SD-006. Tritium was not detected in either of two samples collected from the sewer lift station. The 2014 sample results (excluding MW-9A and MW-13A and one storm water runoff sample) all measured below the required limit of 500 pCi/L. Measurements for 2014 were below the Environmental Protection Agencys drinking water standard of 20,000 pCi/L and present no harm to members of the public.
None of the samples monitored for gamma-emitting isotopes showed activity greater than the LLD.
A summary of the analytical data for ground water monitoring wells and storm water runoff samples is provided in Table E-3. Complete data tables for each period and location are provided in Table E-4.
E-3
3.0 Ground Water Sampling Program 3.1 Program Design and Data Interpretation The purpose of this sampling program is to assess the impact of any tritium leaching into the environment (ground water system) from MNGP. For this purpose, water samples are collected and analyzed for tritium content.
3.2 Program Description The sampling and analysis schedule for the Ground Water Monitoring Program is summarized in Table E-1 and briefly reviewed below. Table E-2 defines the additional sample locations and codes for the Ground Water Sampling Program.
Sampling from the groundwater monitoring wells was conducted monthly for seven locations, quarterly for eight locations, and annually for four locations.
3.3 Program Execution The Program was executed as described with the following exceptions:
Two monitoring well samples for MW-14 were missed in 2014:
- In June 2014, river water levels (912.3 ft) were above the height of the monitoring well riser (911.3 ft).
- In November 2014, the sample was unobtainable due to the well casing being encased in ice.
Additional analyses for gamma emitting isotopes were performed on samples from each of the nineteen monitoring wells. The results are summarized in Table E-3. Results of individual analyses are reported in Table E-4.
3.4 Program Modifications There were no additional on-site monitoring wells added to the ground water program in 2014.
E-4
3.5 Results and Discussions Sampling points in North America have shown tritium concentrations in precipitation may range from 5 pCi/L to 157 pCi/L (Environmental Isotope Data No. 10; World Survey of Isotope Concentration in Precipitation (1988-1991). Results obtained show tritium in ground water samples at or near expected natural background levels, with the exception of monitoring wells, MW-9A and MW-13A.
Excluding the data from wells MW-9A and MW-13A and SD-006, 2014 sample results all measured below an LLD level of 500 pCi/L, and were similar to averages measured in 2013.
The average for 2014 at location MW-9A was 3296 pCi/L which is a decline from the 2013 average of 5457 pCi/L. The highest level that was observed in 2014 was 5911 pCi/L for the November 2014 sample. Three of the monthly samples were below the LLD of 500 pCi/L.
The tritium levels observed at location MW-13A for 2014 ranged from a high of 935 pCi/L in January, fell to 715 pCi/L in February, then stayed below 600 pCi/L for the remainder of the first half of the year and then below the LLD of 500 pCi/L for the remainder of the year.
None of the groundwater samples analyzed for gamma-emitting isotopes showed activity greater than LLD.
E-5
Table E-1. Sample Collection and Analysis Program, Ground Water.
Medium Number Sample Codes Collection type Analysis Type Ground Water 32 MW-1, MW-2, MW-3, MW-4, Grab H-3 Quarterly MW-9B, MW-11, MW-12A, MW-12B, Ground Water 82 MW-9A, MW-10, MW-13A, Grab H-3 Monthly MW-13B, MW-14, MW-15A MW-15B, Ground Water 4 MW-5, MW-6, MW-7, MW-8 Grab H-3 Annual Table E-2. Sampling locations for Ground Water Monitoring Wells.
Sample Type Vendor Well Distance from Compass Sector Code Number Stack (miles) Heading from Stack Ground Water M-33 MW-1 0.11 299 WNW Ground Water M-34 MW-2 0.14 301 WNW Ground Water M-35 MW-3 0.15 305 NW Ground Water M-36 MW-4 0.1 25 NNE Ground Water M-37 MW-5 0.1 253 WSW Ground Water M-38 MW-6 229 Feet 228 SW Ground Water M-39 MW-7 0.2 66 ENE Ground Water M-40 MW-8 0.3 150 SSE Ground Water M-44 MW-9A 0.1 310 NW Ground Water M-51 MW-9B 0.1 310 NW Ground Water M-45 MW-10 0.1 292 WNW Ground Water M-46 MW-11 0.1 283 WNW Ground Water M-47 MW-12A 0.1 330 NW Ground Water M-48 MW-12B 0.1 326 NW Ground Water M-49 MW-13A 0.12 316 NW Ground Water M-50 MW-13B 0.12 316 NW Ground Water M-52 MW-14 0.17 306 NW Ground Water M-53 MW-15A 0.14 14 NNE Ground Water M-54 MW-15B 0.14 14 NNE E-6