XcelEnergysm March 30, 2004 414 Nicollet Mall Minneapolis, Minnesota 55401-1993 Mr. Paul Kim Minnesota Pollution Control Agency Environmental Outcomes Division lntegrated Data Management Unit 520 Lafayette Road N St. Paul, MN 55155 Re:
2003 Air Emission Inventory Reports Enclosed are Northern States Power d/b/a Xcel Energy's 2003 Air Emission Inventory Reports completed and signed for the following facilities owned and operated by.Northern States Power Company d/b/a Xcel Energy:
Facility Name Allenr S. King Alliant Techsystems Black Dog Blue Lake
- General Office Granite. City High Bridge Inver Hills
- Key City Maple Grove Facility ID#
16300005 05300697 03700003 13900010 05300855 00900021 12300012 03700015 01300015 05300898 Facility Name Minnesota Valley Monticello
- Prairie Island
- Red Wing.
Riverside Sherburne County United Healthcare Wescott West Faribault Wilmarth Facility ID #
02300012 17100019 04900030 04900005 05300015 14100004 05300698 03700064 13100003 01300015 Northern States Power d/b/a Xcel Energy also owns and operates three (3) oil-fired generators located at the United Hospital Facility (Permit No. 12300060-002) in St. Paul. These units are included in the facility Emissions Inventory Report which is signed and submitted by United Hospital.
In addition, enclosed are supplemental information sheets for several facilities to assist in the calculations for the Emission Summaries.
If you have any questions, please call me at 612-330-7630.
- Sincerely, Sarah A. Butrymowicz Environmental Analyst IlIl
^ Enclosures
- Page 2 2003 Air Emission Inventory Reports cc:
Environmental Services Record Center Lee Eberley, w/o attachments Rick Rosvold, w/attachments Nancy Stafki, w/attachments John Chelstrom, w/attachments Alma Allen-Webb w/attachments Nancy Stafki - General Office Karen Olson - Maple Grove Mike Miser --Allen S. King Dan Watts - Allen S. King Jim Paris - Black Dog Scott Anton - High Bridge Carl Bayley - Riverside Mary Dieltz - Sherco Gloria Tieszen - Mn Valley Gary Kolle - Prairie Island
- Rick Latsch - Monticello Nathan Svoboda - Wilmarth Arthur Zimmerman - Red Wing Ron Shilts - Wescott Steve Chapman - West Faribault, Blue Lake, Key City, Inver Hills Brian Anderson - United Healthcare, Alliant Techsystems, Granite City
Minnesota Pollution Control Agency Air Pollutant Emission Inventory Report Facility ID: 17100019
. Inventory Year: 2003 Page 1 of 3 Contact Eberdey, Lee W ( 11I )
Facility Name:
Location Street Address:
City/Zp:
County:
NSP dba Xcel Energy Monticello Nuclear 2807 W Highway 75 Monticello 55362 Wright Inventory Contact Eberley, Lee W Job
Title:
Air Quality Manager Mail Address:
414 Nicollet Mall City/St/ZIP:
Minneapolis, MN 55401-i993 Contact Phone:
Contact Fax:
Contact Email:
(612) 330-5596 (612) 330-6357 lee.w.eberdey~xcelenergy.com I certify under penalty of the law that this document and all attachments were prepared under my direction or supervised by qualified personnel. The information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I understand that the data provided in this document will be used by the MPCA to calculate a fee, which my facility will be required to pay under Minnesota Rules, part 7002.0025, based on tons of pollutants emitted by the facility.
"_-ell Signature of and Title of Company Official (please write):
Date:
Z7/f Name and Title of Company Official (please print):
Jack Purkis, Plant Manager Return To: Paul Kim (651) 296-7320 or Michael Smith (651) 282-5849 Minnesota Pollution Control Agency Environmental Outcomes Division Integrated Data Management Unit 520 Lafayette Road N St. Paul, MN 55155-4194
Minnesota Pollution Control Agency Air Pollutant Emissions Inventory Report Facility ID: 17100019 Inventory Year: 2003 Page 2 of 3 Contact Eberley, Lee W( 111)
Monticello Operating Schedule Average Working Schedule
% Annual Throughput Percent Hours Days Hours Dec-Mar-Jun-Sep-Heating Per Per Per Feb May Aug Nov Day Week Year EU 001 Boiler 100 10.4 3.05 3,815 53 28 0
19 EU 002 Diesel Generator 11 0
0.1 0.02 24 24 29 23 24 EU 003 Diesel Generator 12 0
0.1 0.03 36 24 43 16 17 EU 004 Security Diesel Generator 0
0.0 0.01 9
10 31 10 49 EU 005 Fire Pump Diesel Engine 0
0.1 0.03 43 20 31 29 20 EU 006 Diesel Generator 13 0
0.1 0.02 21 19 24 24 33 EU 007 Temporary Engine > 600 Hp N/A N/A N/A N/A.
N/A N/A N/A N/A EU 008 Temporary Engine < 600 Hp N/A N/A N/A N/A N/A N/A N/A N/A
Minnesota Pollution Control Agency Monticello Throughput Information Air Pollutant Emissions Inventory Report Facilty ID: 17100019 Inventory Year: 2003 Page 3 of 3 Contact Eberley, Lee W( 110)
Unit Unit Segment Throughput Throughput Sulfur Ash I.
Description Description Units EU 001 EU 002 EU 003
'EU 004 EU 005 EU 006 EU 007 EU 008 Boiler Diesel 235.14 1000 gallons burned.
<0.05 NIA Diesel Generator. 11 Diesel 4.08 1000 gallons burned
<0.05 N/A Diesel Generator 12 Diesel 6.15 1000 gallons burned
<0.05 N/A Security Diesel Generator Diesel 0.12 1000 gallons burned
<0.05 N/A Fire Pump Diesel Engine
_Diesel 0.35 1000 gallons burned
<0.05 A
Diesel Generator 13 Diesel 2.34 1000 gallons burned
<0.5 N/A Temporary Engine > 600 Hp Diesel NIA 1000 gallons burned N/A N/A Temporary~~~~~ ~~
~
~
~ E.ie < 6 0 H i s lN A10 0 g lo s b r e
/
- Temporary Engine < 600 Hp Diesel N/A
.1000 gallons burned N/A N/A
I 6 I
I Unit #
Unit Segment SCC Pollutant Emission Calculation Control Control Capture Comb Emissions Description Description Factor Method Equipment %
(in tons)
EU001 Boiler Fuel Oil NOx Test 3.08 TSP/PM AP-42 0.24 SOx AP-42 3.81
- EU002, Generator Diesel NOx Test 2.71 003, &
TSP/PMIV AP-42 0.06 Sox AP-42 0.25 Note: NOx emissions from generators11, 12 &13 have been combined. See attached letter(s).
4 Air Pollutant Emissions Inventory Report 2003 Operating Schedule
,1;,Bi~iinyS;:IGE 4rM~I i. S
'i tI ~ Mail';
ItJu IQ;~
-ht k8)!iJul~+LAuq :l ff¢..'>Se Vp'si. ~Ot tU~ii4L:Nb v~I."De R 1ti 01l6Iterl,0 742.2 674.2 737.4 288.4
. 39.2 7.3 0.0 8.3 31.9 184.1 490.1 612.0 2.0 1.9 1.7 2.4 2.9 1.6 2.1 1.9 1'.6 2.2 1.9 1.8 D
A 4.6 2.3 2.6 1.8 11.1 1.7 2.5 1.7 1.9 2.5 1.8 1.7 0.2 0.4 0.3 2.6 0.0 0.3 0.3 0.3 0.3 1.9 2.4 0.3 Fle I UW-f Gi 2.30 2.80 2.83 2.89 7.80 6.44 2.84 3.01 2.12 4.44 2.20 3.40 DG(1 3;,
Z5'i 1.0 2.0 2.0 2.0 1.0 2.0 1.0 2.0 2.0 2.0 3.0 1.0 H
Eln j bifWL" 2488.7 1326.4 fi 12.5-11.5 24.1 12.1 ssMGF4i
-3.8
'5.5 RI R7RfMm i!
25.1 18.0 i,04 LI 10.0 11.0 I
irsW~stlz~fi~lfitpllR~f671blThrQS9sfA~I
'4
,r-Xrint *i"Y"1?
rrvfiwiA Ma rceWsiNkW.ibsd;eF4k§W ENinis fliI SRfik KI 6 LNsM Z
oi s-
/
AMn 15 BI R!
10.45 3.05 3815.1 53.2 27.9 0.4 18.5 100.0 i
0.0657 0.0192 24.0 23.8 29.2 23.3 23.8 100.0 0.0991 0.0289 36.2 23.8 42.8 16.3 17.1 100.0
.tr;> 0.0255 0.0074 9.3 9.7 31.2 9.7 49.5 100.0 0166101L~ft 0.1179 0.0344 43.1 19.7 31.41 28.51 20.3 100.0 VOM)4,13-151M.MWENR 0.0575 0.0168 21.0 19.0 23.81 23.8 33.3 100.0
Air Pollutant Emissions Inventory Report 2003 Throughput Information J6;tnm, X
Y-.S.-.,
5, glh i. J,Ja
- 7,1
. u ^-
T OcNv i
>^.ta I 7K 1 T KQ~ti3l r
47
.2 42964.7 35405.3 15030.2 2457.5 442.4 0.0 0.0 2595.6 13340.6 33662.9 41903.0 235.14 1,000 Gallons Burned D 41,.- iS.,'
340.0 323.0 289.0 408.0 493.0 272.0 357.0 323.0 272.0 374.0 323.0 306.0 4.08 1,000 Gallons Burned D04 lC;ii.
782.0 391.0 442.0 306.0 1887.0 289.0 425.0 289.0 323.0 425.0 306.0 289.0 6.15 1,000 Gallons Burned Sir tlQPE 2.6 5.1 3.8 33.3 0.0 3.81 3.8 3.8 3.8 24.3 30.7 3.8 0.12 1,000 Gallons Burned F0iunGi' 18.6 22.7 22.9 23.4 63.2 52.2 23.0 24.4 17.2 36.0 17.8 27.5 0
.35 1,000 Gallons Burned DG,13J1/24',
111.2 222.4 222.4 222.4 111.2 222.4 111.2 222.4 222.4 222.4 333.6 111.2 2.341,000 Gallons Burned HtIWMM l frf 143.64 9`1.50 235.14 1,000 Gallons Burned 2.13 1.96 4.08 1,000 Gallons Burned 4.10 2.06 6.15 1,000 Gallons Burned O
ft 0.05 0.07 0.12 1,000 Gallons Burned EirilBum QGl 0.20 0.15 0.35 1,000 Gallons Burned 1.11 1.22 2.34 1,000 Gallons Burned
Monticello Nuclear Generating Plant Fuel Usage Report Period Covered:
January 1 - June 30, 2003 MPCA Emission Unit No.
Fuel Hours Consumption Onerated Rate (gal/hr)
Fuel Amount Used (Lal)
NOx Emission Rate 2,3,4,6 (lb/gal)
NOx Emissions (tons)
S02 Emission Rate 4,5,6 (IOb/al)
S02 Emissions (tons)
PM Emission Rate 4,6 (lh/eaI)
PM Emissions (tons)
Unit
-r
- \\es Boiler I EU0OI 208.6 143,638 Dl l
EU002 12.5 170 2,125 D12 EU003 24.1 170 4,097 Security EU004 3.8 12.8 49 Fire Pump EU005 25.1 8.1 203 D13 EU006 10.0 111.2 1,112 (7
I I -
0.0262 1.88 0.00720 0.52 0.0020 0.14 0.4480 0.48 0.00707 0.01 0.0098 0.01 0.4480 0.92 0.00707 0.01 0.0098 0.02 0.6174 0.02 0.00406 0.00 0.0434 0.00 0.6174 0.06 0.00406, 0.00 0.0434 0.00 0.3602 0.20 0.070701 0.04 0.0098
. 0.01 Totals 151,224 3.55 0.58 0.18
- 1. Fuel consumption rates (maxiumum capacity) taken from Title V application.
- 2. BoilerNOx emission rate from 1/1/1996 stack test.
- 3. D13 NOx emission rate from 10/18 2000 stack test.
- 4. Boiler emission rates from MPCA Table EC-02.1; Engine emission rates from MPCA Table EC-03.1 (lb/mmBTU rates converted to lbs/gal)
S. Assumes 0.5% S in fuel for D13 and 0.05% S for all other units.
- 6. Assumes fuel heat value of 140,000 Btu/gal shaded area represents manually entered data.
Monticello Nuclear Generating Plant Fuel Usage Report Period Covered:
July 1 - December 31, 2003 MPCA Emission Unit Unit No.
Fuel Hours Consumption Operated Rate (gal/hr) 1 Fuel Amount Used (gal)
NOx Emission Rate 2,3,4,6 (lb/gal)
NOx Emissions (tons)
S02 Emission Rate 4,5,6 (lb/gal)
S02 Emissions (tons)
PM Emission Rate 4,6 (lb/eahl PM Emissions (tons)
Boiler I EUOO1 208.6 91,510 DII EU002 11.5 170 1,955 D12 EU003 12.1 170 2,057 Security EU004 5.5 12.8 70 Fire Pump EU005618.0 8.11 146 D13 JEU006 I
11.01 111.21 1,223 I
\\ -
I A_/-1 n-/------
0.0262 1.20 0.0720 3.29 0.0020 0.09 0.4480 0.44 -
0.0707 0.07 0.0098 0.01 0.4480 0.46 0.0707 0.07 0.0098 0.01 0.6174 0.02 0.0406 0.00 0.0434 0.00 0.6174 0.05 0.0406 t 0.00 0.0434 0.00 0.36021 0.22 0.0707 l'
0.04 0.0098 0.01 Totals 96,962 2.38 3.48 0.12
- 1. Fuel consumption rates (maxiumum capacity) taken from Title V application.
- 2. Boiler NOx emission rate from 1/1/1996 stack test.
- 3. D13 NOx emission rate from 10/18 2000 stack test.
- 4. Boiler emission rates from MPCA Table EC-02.1; Engine emission rates from MPCA Table EC-03.1 (lb/mmBTU rates converted to lbs/gal)
- 5. Assumes 0.5% S in fuel.
- 6. Assumes fuel heat value of 140,000 Btu/gal shaded area represents manually entered data.