ML15282A235

From kanterella
Jump to navigation Jump to search

RHR Heat Exchange K-values Utilities in EPU Containment Analyses
ML15282A235
Person / Time
Site: Browns Ferry  
(DPR-033, DPR-052, DPR-068)
Issue date: 09/21/2015
From:
Tennessee Valley Authority
To:
Office of Nuclear Reactor Regulation
Shared Package
ML15282A154 List: ... further results
References
CNL-15-169
Download: ML15282A235 (15)


Text

ATTACHMENT 39 Heat Exchanger K Values Utilized in EPU Containment Analyses

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-1 1.0 Introduction This attachment provides EPU event-specific RHR heat exchanger K-values and heat removal rates for postulated events. The heat exchanger K-value determinations in this attachment confirm that the specific K-value used in each containment analysis is appropriate and suitable for the expected EPU conditions.

The Browns Ferry Nuclear Plant original design value for the RHR heat exchanger effectiveness K-value is 223 BTU/sec-°F.

In Reference 4.3, TVA previously submitted a License Amendment Request (LAR) to transition the licensing basis for the Browns Ferry Nuclear Plant to National Fire Protection Association standard 805 (NFPA 805) which, in (Ref. 4.3) Attachment X and subsequent responses to NRC requests for additional information (RAIs) (Ref. 4.4), included a change to the RHR heat exchanger K-value from 223 BTU/sec-°F to 265 BTU/sec-°F and provided the basis for the change to the K-value. The extended power uprate (EPU) design value used for the containment analyses under the design basis accident (DBA) loss of coolant accident (LOCA),

for containment heat removal is 265 BTU/sec-°F, which is consistent with the NFPA 805 LAR (CLTP) K-value of 265 BTU/sec-°F. However, this EPU LAR attachment also identifies changes to specific values reported in the NFPA 805 LAR. These changes are addressed in the following paragraph.

In the NFPA 805 transition LAR (Ref. 4.3) and associated RAI responses (Ref. 4.4) the RHR heat exchanger overall fouling resistance corresponding to a K-value of 265 BTU/sec-°F and a peak suppression pool temperature of 187.4°F (DBA-LOCA temperature) was reported to be 0.001517 hr-ft2-°F/BTU. This fouling resistance corresponds to a K-value of 284.5 BTU/sec-°F at the CLTP NFPA 805 fire event conditions. However, for conservatism, a K-value of 270 BTU/sec-°F is used in the CLTP NFPA 805 fire event analyses. This attachment provides a re-calculated DBA-LOCA EPU design fouling resistance associated with a K-value of 265 BTU/sec-°F for a peak suppression pool temperature of 179.0°F. This change in the peak suppression pool temperature from 187.4°F to 179.0°F results in a slightly different EPU design fouling resistance, 0.001521 hr-ft2-°F/BTU. The values of DBA-LOCA peak suppression pool temperature and design fouling resistance that were provided in the NFPA 805 LAR (Ref. 4.3) are superseded by the EPU values provided herein, 179.0°F and 0.001521 hr-ft2-°F/BTU, respectively, and reflect updated EPU analyses.

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-2 EPU licensing basis RHR heat exchanger K-values are as follows:

EPU event K-value (BTU/sec-°F)

DBA-LOCA 265 Small Break LOCA 265 Loss of Shutdown Cooling 265 Stuck Open Relief Valve 265 Station Blackout (SBO) 265 ATWS 277 Shutdown of Non-Accident Unit 302 Fire 307*

  • In addition, the fire event was analyzed using the Emergency High Pressure Make-Up (EHPMU) pump and an RHR heat exchanger K-value of 287 BTU/sec-°F. This represents a defense-in-depth demonstration and is not a licensing basis analysis.

The Browns Ferry Nuclear Plant Updated Final Safety Analysis Report (UFSAR) (Ref. 4.5) provides additional descriptive information concerning the Residual Heat Removal (RHR) heat exchangers in UFSAR sections 1.6.2.12 (Residual Heat Removal System (Containment Cooling)), 4.8.6.2 (Containment Cooling), 4.8.6.3 (Low Pressure Coolant Injection), Table 4.8-1 (Residual Heat Removal System Equipment Design Data) and Table 5.2-1 (Principal Design Parameters and Characteristics of Primary Containment).

2.0 Computations and Analysis 2.1 Methodology The methodology utilizes an Excel spreadsheet platform, and standard engineering formulas, to solve for the RHR heat exchanger K-value based on the input parameter values.

The formula for heat exchanger effectiveness is a function of the overall heat transfer coefficient, the effective heat transfer area, and other parameters identified below. The Browns Ferry Nuclear Plant RHR heat exchangers are identical single shell pass, two tube pass Tubular Exchanger Manufacturers Association, Inc. (TEMA) type CES heat exchangers. The effectiveness for this type heat exchanger is:

(

)

(

)

(

)

1 1

1 5.0 5.0 2

5.0 2

2 1

1 1

1 2

+

+

+

+

+

+

=

R R

C NTU C

NTU R

R e

e C

C e

(Equation 1 - Ref. 4.1)

Where:

e

= heat exchanger effectiveness CR

= heat capacity ratio

= Cmin/Cmax

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-3 Cmin = minimum mass flow rate times fluid heat capacity product, BTU/hr-oF Cmax = maximum mass flow rate times fluid heat capacity product, BTU/hr-oF NTU

= number of transfer units

= UA/Cmin U

= overall heat transfer coefficient, BTU/hr-ft2-°F A

= effective heat transfer area, ft2 Equation 1 was used to determine fouling resistance and/or K-values for various state points for the analyzed event sequences.

Tables 1, 2, and 3, below, provide the results from specific evaluations using the overall fouling resistance and the corresponding heat exchanger K-value for each of the fouling resistances in Table 4. The specified fouling resistances cover a wide range from the original supplied RHR heat exchanger design fouling resistance (0.002800 hr-ft2-°F/BTU) to a clean RHR heat exchanger fouling resistance (0.000000 hr-ft2-°F/BTU). Specifically, the EPU design fouling resistance, 0.001521 hr-ft2-°F/BTU; the EPU nominal fouling resistance, 0.001097 hr-ft2-°F/BTU and the fouling resistances determined from six different Browns Ferry Nuclear Plant RHR heat exchanger tests performed to date are some of the more significant fouling resistances.

Table 4 provides a comparison summary of heat exchanger heat transfer rates and corresponding K-values for the different EPU K-values used in the event analyses:

  • 265 BTU/sec-°F (DBA-LOCA, Small Break LOCA, Loss of Shutdown Cooling, Stuck Open Relief Valve and SBO), 302 BTU/sec-°F (Shutdown of Non-Accident Unit), and 287 BTU/sec-°F (fire event defense-in-depth demonstration case) are based on the EPU design fouling resistance, 0.001521 hr-ft2-°F/BTU.
  • 307 BTU/sec-°F (fire event licensing basis) is based on the EPU nominal fouling resistance, 0.001097 hr-ft2-°F/BTU.
  • 277 BTU/sec-°F for the ATWS-MSIVC-EOC event corresponds to a nominal fouling resistance of 0.001220 hr-ft2-°F/BTU.

2.2 Analysis RHR heat exchanger K-values used in the containment analyses are identified for each event within the applicable Browns Ferry Nuclear Plant Power Uprate Safety Analysis Report (PUSAR) section. Unless otherwise noted and discussed below for ATWS and fire events, all events were evaluated at the EPU design fouling resistance (same heat exchanger material condition). For the same EPU design fouling resistance, differences in RHR and Residual Heat Removal Service Water (RHRSW) flow rates from one event to another may result in different RHR heat exchanger K-values (see Table 4).

The DBA LOCA discussion provides the basis for the change in the pre-EPU and the EPU design fouling resistance and the corresponding EPU K-value of 265 BTU/sec-°F. The Shutdown of the Non-Accident Unit analysis K-value is also based on the EPU design fouling resistance, 0.001521 hr-ft2-°F/BTU. The EPU fire event analysis K-value was based on the EPU nominal fouling resistance, 0.001097 hr-ft2-°F/BTU and the ATWS event analyses were based on a nominal fouling resistance or K-value that lies between the EPU design and EPU nominal fouling resistances. Details are provided in the following discussion of the events.

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-4 DBA-LOCA - PUSAR Section 2.6.5.1 The EPU design basis fouling resistance is based on the conditions from the EPU DBA-LOCA. Specifically, the RHR flow rate of 6500 gpm at a peak suppression pool temperature (heat exchanger inlet temperature) of 179.0°F, RHRSW flow rate of 4000 gpm at 95°F RHRSW temperature, with up to 4.57 percent tube plugging, and an RHR heat exchanger K-value of 265 BTU/sec-°F are used to determine the EPU design basis fouling resistance.

Equation 1 is used to solve for fouling resistance, based on a given K-value or, to calculate a K-value based on a specified fouling resistance, provided the other state points are known.

The EPU containment response analyses were performed for the long-term DBA-LOCA using a RHR heat exchanger K-value of 265 BTU/sec-°F compared to 223 BTU/sec-°F used in previous analyses. The previous value of 223 BTU/sec-°F was based on the RHR heat exchanger specification sheets, which specified the design fouling resistances. Browns Ferry Nuclear Plant plant-specific RHR heat exchanger testing (Ref. 4.4, including SCVB RAI-5) has shown there is substantial margin between the design and actual (tested) heat exchanger fouling resistances.

Some of this large margin was used to increase RHR heat exchanger heat transfer capability from that specified in the original design to a K-value of 265 BTU/sec-°F. The corresponding EPU design fouling resistance at the DBA-LOCA conditions identified above is 0.001521 hr-ft2-°F/BTU.

Under certain scenarios, higher RHR and/or RHRSW flows may be achieved than those used to establish the EPU design basis fouling resistance. Using minimum flow rates in determining the RHR heat exchanger heat removal capability embeds conservatism into the containment analysis results. A lower containment heat removal rate results in higher suppression pool temperatures; thus, the analysis is conservative with respect to suppression pool temperature.

Other events, including the small break LOCA, loss of RHR shutdown cooling, stuck open relief valve (SORV), and station blackout, were evaluated using an RHR heat exchanger K-value of 265 BTU/sec-°F and are described in PUSAR Section 2.6.5.2.

Shutdown of the Non-Accident Unit - PUSAR Section 2.6.5.1 An RHR heat exchanger K-value of 302 BTU/sec-°F was used in the analysis of the shutdown of the non-accident unit. This value represents the K-value resulting from a design basis fouling resistance, RHR flow of 9700 gpm at the peak suppression pool temperature of 185.1°F, RHRSW flow of 4500 gpm at 95°F, and 4.57 percent tube plugging. These parameters are consistent with the analysis inputs/results described in PUSAR Section 2.6.5.1.

Fire Event - PUSAR Section 2.5.1.4.2 The fire event analysis assumes one RHR heat exchanger available for event mitigation. All other RHR heat exchangers are assumed to be not available which restricts containment heat removal capability. Of all the events analyzed, because of restrictive/conservative assumptions, such as the availability of only one RHR pump and heat exchanger, the fire event results in the highest peak suppression pool temperature. In-situ RHR heat exchanger performance testing (results previously submitted under Browns Ferry Nuclear Plant

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-5 NFPA 805 LAR (Ref. 4.3) Attachment X and associated RAI responses (Ref. 4.4))

demonstrate that the actual heat removal capability of RHR heat exchangers exceeds that assumed in the fire event containment analysis.

An RHRSW flow of 4500 gpm is achievable for the fire event. The combination of increased RHRSW flow and the use of a realistic or nominal heat exchanger fouling resistance, 0.001097 hr-ft2-°F/BTU, corresponds to an increase in the EPU fire event heat exchanger K-value to 307 BTU/sec-°F. As discussed in PUSAR Section 2.5.1.4.2, a fire event containment analysis was performed using the K-value of 307 BTU/sec-°F which resulted in a peak suppression pool temperature of 208.0°F.

SECY-11-0014 (Ref. 4.8) provides guidance on the use of realistic or nominal inputs for special events such as a fire event. For the Browns Ferry Nuclear Plant EPU, when a nominal K-value was selected or established, the heat exchanger test data available for comparison to the selected realistic or nominal value was limited to that reported in the NFPA 805 LAR (Ref. 4.3) Attachment X and associated RAI responses (Ref. 4.4). These reported as tested fouling resistances of 0.0005164 and 0.000674 hr-ft2-°F/BTU, are shown on Figure 1, and resulted in a large difference between the test results and the EPU design (0.001521 hr-ft2-°F/BTU) fouling resistance. To provide confidence in establishing a reasonable realistic or nominal heat exchanger fouling resistance, industry literature was consulted for establishing the realistic or nominal fouling resistance.

EPRI Test Report 107397, Service Water Heat Exchanger Testing Guidelines, (Ref. 4.2) section 3.4.2 provides guidance in establishing an acceptance criterion for test uncertainty to determine whether a given test result is acceptable. The guidance suggests that an initial acceptance criterion can be established in terms of the heat transfer rate, at +/- 25 percent of the difference between the design and clean (zero fouling resistance) heat transfer rates.

This provided a reasonable bound for establishing the expected deviation from a design heat transfer rate to an actual or tested heat transfer rate. The realistic or nominal fouling resistance was determined by taking 25 percent of the difference between the EPU fire event design heat transfer rate and the clean heat transfer rate and adding that to the EPU design heat transfer rate to obtain the heat transfer rate corresponding to the realistic or nominal fouling resistance. The results of this computation are provided in Table 4 where this process was followed to determine the fire event K-value, 308 BTU/sec-°F. The value chosen for the RHR heat exchanger fire event nominal K-value was 307 BTU/sec-°F, which is within the range from 287 BTU/sec-°F (EPU design) to 308 BTU/sec-°F.

The nominal fire event K-value of 307 BTU/sec-°F represents an approximate 7 percent increase from the EPU fire event design K-value of 287 BTU/sec-°F (computed using the EPU design fouling resistance, 0.001521 hr-ft2-°F/BTU, 7500 gpm RHR flow at 208.0°F, 4500 gpm RHRSW flow at 92.0°F and 4.57 percent of the tubes plugged). This approximate 7 percent increase in the EPU fire event design K-value to the EPU fire event nominal K-value compared well with an NRC staff assessment (Ref. 4.6) where conservative and realistic RHR heat exchanger K-values were determined and compared at 147 and 158 BTU/sec-°F, respectively. The increase from 147 BTU/sec-°F to 158 BTU/sec-°F constitutes an approximate 7.5 percent increase in the conservative or design basis K-value, which compares well to the Browns Ferry Nuclear Plant 7 percent increase described above.

Using the nominal fire event K-value of 307 BTU/sec-°F, Equation 1 was used to solve for the resulting EPU nominal fire event fouling resistance, 0.001097 hr-ft2-°F/BTU (see Table 3). This fouling resistance is used for comparison to Browns Ferry Nuclear Plant RHR

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-6 heat exchanger test results graphically presented in Figure 1. Figure 1 provides the results from the tests performed to date.

Comparison of the Browns Ferry Nuclear Plant RHR heat exchanger test results to the EPU design and nominal fouling resistances shown in Figure 1 leads to two clear observations:

(1) the results from the 2A RHR heat exchanger as-found test (two years since last cleaning) closely match the EPU fire event nominal fouling resistance and, (2) the 2A RHR heat exchanger as-left test results (0 years since last cleaning) when compared with the 2A RHR heat exchanger as-found test results and the other three heat exchanger test results show that the 2A RHR heat exchanger performance, when expressed in terms of fouling resistance, is not as good as the other heat exchangers. These (identical in design) heat exchangers when subjected to identical operating conditions would be expected to demonstrate essentially identical performance; however, the as-tested performance of the 2A RHR heat exchanger differs from that of the other heat exchangers. This apparent anomalous performance of the 2A RHR heat exchanger has been entered into the Browns Ferry Nuclear Plant corrective action program to identify the condition and evaluate the issue to resolution.

The difference between the RHR heat exchanger test results (including the 2A RHR heat exchanger) and the EPU design fouling resistance serves to demonstrate the conservatism embedded in the event analyses where the RHR heat exchanger K-value is determined from the EPU design fouling resistance.

The difference between the RHR heat exchanger test results (excluding the 2A RHR heat exchanger) and the EPU fire event nominal fouling resistance serves to demonstrate that the EPU fire event nominal fouling resistance is appropriate for use in fire event analyses.

The fire event sensitivity case with the EHPMU pump reported in PUSAR Section 2.6.5.2, PUSAR Tables 2.6-4 and 2.6-4a did not use a realistic or nominal heat exchanger fouling resistance but instead used a K-value, 287 BTU/sec-°F, corresponding to the EPU design fouling resistance, 0.001521 hr-ft2-°F/BTU. The sensitivity case demonstrates defense-in-depth for a fire event.

The current licensed thermal power (CLTP) analysis in Table 4 summarizes the fire event analysis parameters and the K-value used in the analysis submitted in the NFPA 805 LAR.

As indicated in Table 4, the CLTP NFPA 805 analysis was performed assuming 4400 gpm RHRSW flow and an RHR heat exchanger K-value of 270 BTU/sec-°F. For EPU the RHRSW flow rate is 4500 gpm and the RHR heat exchanger K-value is 307 BTU/sec-°F, as discussed above. No modifications are required to effect the change in the RHRSW flow rate from 4400 gpm to 4500 gpm as the CLTP analysis was performed using a conservatively low flow rate compared to the actual RHRSW flow capability during a fire.

Anticipated Transient Without Scram (ATWS) - PUSAR Sections 2.6.5.2 and 2.8.5.7 The limiting ATWS event with respect to peak suppression pool temperature is the ATWS loss-of-offsite power (LOOP) event (two RHR pumps and two RHR heat exchangers credited) which resulted in a peak suppression pool temperature of 173.3°F. The most limiting non-LOOP (four RHR pumps and four RHR heat exchangers credited) ATWS event is the Main Steam Isolation Valve Closure-End of Cycle (MSIVC-EOC) event which experiences a peak suppression pool temperature of approximately 171.7°F. When the combined transient effects of pool temperature, pool level and pump suction losses are

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-7 considered, the limiting ATWS event from a net positive suction head (NPSH) perspective is a non-LOOP event (MSIVC-EOC). For Browns Ferry Nuclear Plant EPU ECCS pump NPSH, MSIVC-EOC remains the most limiting ATWS event.

An RHR heat exchanger K-value of 277 BTU/sec-°F was used in each ATWS analysis. The K-value corresponds to an RHRSW temperature of 95°F, 4500 gpm RHRSW flow, RHR (heat exchanger shell inlet) temperature of 173.3°F (peak suppression pool temperature for ATWS-LOOP event as discussed in PUSAR Sections 2.6.5.2 and 2.8.5.7.2),

6500 gpm RHR flow and 4.57 percent tube plugging, at the EPU design fouling resistance, 0.001521 hr-ft2-°F/BTU, is 277.8 BTU/sec-°F. These conditions are applicable for the ATWS-LOOP event where only two heat exchangers in the ATWS unit are credited with mitigating the event.

Where four RHR heat exchangers in the same unit are credited with mitigating the ATWS event, system hydraulic resistances in common RHRSW piping on the discharge side of the RHR heat exchangers and in the discharge piping where the two loops combine into common piping, results in the RHRSW flow being restricted such that only 4000 gpm is passed through each of the four heat exchangers. This explains the reduction in the RHRSW flow rate per heat exchanger from 4500 gpm per heat exchanger in the two heat exchanger alignment described above, to 4000 gpm per heat exchanger in the four heat exchanger alignment. The effect of this condition on the EPU ATWS analyses is described below.

The analyses K-value of 277 BTU/sec-°F used in the non-LOOP ATWS events, corresponds to a fouling resistance of 0.001220 hr-ft2-°F/BTU. This was determined using Equation 1 with RHRSW temperature at 95°F, 4000 gpm RHRSW flow, RHR (heat exchanger shell inlet) temperature of 171.7°F, 6500 gpm RHR flow, and 4.57 percent tube plugging. This reduced fouling resistance of 0.001220 hr-ft2-°F/BTU is justified because it is conservative relative to the EPU nominal fouling resistance of 0.001097 hr-ft2-°F/BTU (see Figure 1). In addition, the difference between the RHR heat exchanger test results (including the 2A RHR heat exchanger) and this reduced fouling resistance value serves to demonstrate that this fouling resistance value is appropriate for use in ATWS event analyses.

2.3 RHR Heat Exchanger Performance Monitoring In Attachment X,Section X.4 of Reference 4.3, TVA stated that the Browns Ferry Nuclear Plant RHR heat exchangers would be subject to a performance monitoring program to provide assurance that heat exchanger fouling that could affect the required heat transfer rate is detected and corrected in a timely manner. Reference 4.7 also included a commitment (i.e., Commitment 2) to implement a heat exchanger monitoring program to provide assurance that the RHR heat exchanger performance is maintained for consistency with analytical assumptions associated with the adoption of the NFPA 805 standard.

Because the revised performance monitoring program has not been developed at this time, the commitment specifies implementation within six months following NRC issuance of the license amendment approving adoption of the NFPA 805 standard for the Browns Ferry Nuclear Plant. In addition, TVA will revise the program that monitors Browns Ferry Nuclear Plant RHR heat exchanger performance for consistency with the assumptions used in analyses supporting EPU prior to EPU license amendment implementation. TVA intends to include, as requirements in the program, periodic heat exchanger inspections and heat exchanger performance testing requirements to ensure fouling factor assumptions and tube plugging assumptions in the EPU containment analyses remain valid.

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-8 3.0 Summary and Conclusion Based on the analyses described above, the RHR heat exchanger fouling resistances and K-values used in the EPU event analyses are appropriate:

  • The EPU design fouling resistance is 0.001521 hr-ft2-°F/BTU. This was determined using a heat exchanger K-value of 265 BTU/sec-°F with an RHR flow rate of 6500 gpm at RHR (heat exchanger shell side inlet) temperature of 179.0°F, RHRSW flow rate of 4000 gpm at RHRSW inlet temperature of 95°F with 4.57 percent tubes plugged;
  • The EPU nominal fouling resistance is 0.001097 hr-ft2-°F/BTU; and
  • RHR heat exchanger as-found test results demonstrate the EPU design and nominal fouling resistance values are appropriate for use in the associated event analyses.

In addition, periodic RHR heat exchanger performance testing will be used to demonstrate that actual heat exchanger performance exceeds the performance credited in the analyses.

4.0 References 4.1 Fundamentals of Heat and Mass Transfer by Frank P. Incropera and David P. Dewitt, John Wiley & Sons, 3rd Edition, 1990 4.2 EPRI Test Report 107397, Service Water Heat Exchanger Testing Guidelines, Electric Power Research Institute, March 1998 4.3 TVA Letter to NRC, License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants (2001 Edition) (Technical Specification Change TS-480), March 27, 2013 (ADAMS Accession Number ML13092A392) 4.4 TVA Letter to NRC, Response to NRC Request for Additional Information Regarding the License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants for the Browns Ferry Nuclear Plant, Units 1, 2, and 3 (TAC Nos. MF1185, MF1186, and MF1187) -

Attachment X and Fire Modeling, June 13, 2014 (ADAMS Accession Number ML14167A175) 4.5 Browns Ferry Nuclear Plant Updated Safety Analysis Report, Sections 1.6.2.12, 4.8.6.2, 4.8.6.3, Table 4.8-1, and Table 5.2-1 4.6 NRC Memorandum to ACRS Members, Certification of the Meeting Minutes from the Advisory Committee on Reactor Safeguards 572nd Full Committee Meeting Held on May 6-8 2010 in Rockville, Maryland, August 16, 2010 (ADAMS Accession Number ML101830190) 4.7 TVA Letter to NRC, Response to NRC Request to Supplement License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants for the Browns Ferry Nuclear Plant, Units 1, 2, and 3 (TAC Nos. MF1185, MFl186, and MF1187), May 16, 2013 (ADAMS Accession Number ML13141A291)

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-9 4.8 SECY-11-0014 - Use of Containment Accident Pressure in Analyzing Emergency Core Cooling System and Containment Heat Removal System Pump Performance in Postulated Accidents, U.S. Nuclear Regulatory Commission, January 31, 2011, (ADAMS Accession No. ML102590196)

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-10 Table 1 Overall Fouling Resistances and K-values for Events with RHR Flow Rate 6500 gpm Event Trhr2 Tsw3 RHRSW Flow Overall Fouling Resistance K

Tube Plugging5 F

F gpm hr-ft2-°F/Btu Btu/sec-°F percent DBA-LOCA (RSLB1) 179.0 95 4000 0.000000 333.7 4.57 DBA-LOCA (RSLB) 179.0 95 4000 0.000461 310.7 4.57 DBA-LOCA (RSLB) 179.0 95 4000 0.0005164 308.1 4.57 DBA-LOCA (RSLB) 179.0 95 4000 0.000674 300.7 4.57 DBA-LOCA (RSLB) 179.0 95 4000 0.000820 294.0 4.57 DBA-LOCA (RSLB) 179.0 95 4000 0.000930 289.1 4.57 DBA-LOCA (RSLB) 179.0 95 4000 0.001107 281.6 4.57 DBA-LOCA (RSLB) 179.0 95 4000 0.001097 282.0 4.57 DBA-LOCA (RSLB) 179.0 95 4000 0.001521 265.0 4.57 DBA-LOCA (RSLB) 179.0 95 4000 0.0028004 223.1 4.57 ATWS-LOOP 173.3 95 4500 0.000000 355.6 4.57 ATWS-LOOP 173.3 95 4500 0.000461 329.2 4.57 ATWS-LOOP 173.3 95 4500 0.0005164 326.2 4.57 ATWS-LOOP 173.3 95 4500 0.000674 317.8 4.57 ATWS-LOOP 173.3 95 4500 0.000820 310.3 4.57 ATWS-LOOP 173.3 95 4500 0.000930 304.8 4.57 ATWS-LOOP 173.3 95 4500 0.001107 296.3 4.57 ATWS-LOOP 173.3 95 4500 0.001097 296.8 4.57 ATWS-LOOP 173.3 95 4500 0.001521 277.8 4.57 ATWS-LOOP 173.3 95 4500 0.0028004 231.9 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.000000 333.9 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.000461 310.9 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.0005164 308.2 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.000674 300.8 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.000820 294.2 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.000930 289.3 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.001107 281.7 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.001097 282.1 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.001220 277.0 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.001521 265.1 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.0028004 223.2 4.57 Notes

1.

RSLB = recirculation suction line break

2.

Trhr = temperature - residual heat removal

3.

Tsw = temperature - service water

4.

Heat exchanger original design fouling resistance

5. The current condition (number of tubes plugged) of each RHR heat exchanger is bounded by the design value of 4.57 percent tubes plugged. Work processes prohibit returning an RHR heat exchanger (HX) to service following maintenance with more than 4.57 percent tubes plugged without proper design and licensing basis review/evaluation being performed.

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-11 Table 2 Overall Fouling Resistances and K-values for Events with RHR Flow Rate 9700 gpm Event Trhr1 Tsw2 RHRSW Flow Overall Fouling Resistance K

Tube Plugging4 F

F gpm hr-ft2-°F/Btu Btu/sec-°F percent Shutdown of Non-Accident Unit 185.1 95 4500 0.000000 398.3 4.57 Shutdown of Non-Accident Unit 185.1 95 4500 0.000461 365.0 4.57 Shutdown of Non-Accident Unit 185.1 95 4500 0.0005164 361.3 4.57 Shutdown of Non-Accident Unit 185.1 95 4500 0.000674 350.9 4.57 Shutdown of Non-Accident Unit 185.1 95 4500 0.000820 341.7 4.57 Shutdown of Non-Accident Unit 185.1 95 4500 0.000930 335.0 4.57 Shutdown of Non-Accident Unit 185.1 95 4500 0.001107 324.6 4.57 Shutdown of Non-Accident Unit 185.1 95 4500 0.001097 325.2 4.57 Shutdown of Non-Accident Unit 185.1 95 4500 0.001521 302.4 4.57 Shutdown of Non-Accident Unit 185.1 95 4500 0.0028003 248.4 4.57 Notes

1.

Trhr = temperature - residual heat removal

2.

Tsw = temperature - service water

3.

Heat exchanger original design fouling resistance

4. The current condition (number of tubes plugged) of each RHR heat exchanger is bounded by the design value of 4.57 percent tubes plugged. Work processes prohibit returning an RHR HX to service following maintenance with more than 4.57 percent tubes plugged without proper design and licensing basis review/evaluation being performed.

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-12 Table 3 Overall Fouling Resistance and K-values for Events with RHR Flow Rate 7500 gpm Event Trhr1 Tsw2 RHRSW Flow Overall Fouling Resistance K

Tube Plugging4 F

F gpm hr-ft2-°F/Btu Btu/sec-°F percent FIRE - CLTP 205.7 92 4400 0.000000 366.4 4.57 FIRE - CLTP 205.7 92 4400 0.000461 338.3 4.57 FIRE - CLTP 205.7 92 4400 0.0005164 335.1 4.57 FIRE - CLTP 205.7 92 4400 0.000674 326.3 4.57 FIRE - CLTP 205.7 92 4400 0.000820 318.3 4.57 FIRE - CLTP 205.7 92 4400 0.000930 312.5 4.57 FIRE - CLTP 205.7 92 4400 0.001107 303.6 4.57 FIRE - CLTP 205.7 92 4400 0.001097 304.1 4.57 FIRE - CLTP 205.7 92 4400 0.001521 284.2 4.57 FIRE - CLTP 205.7 92 4400 0.001856 270.0 4.57 FIRE - CLTP 205.7 92 4400 0.0028003 236.2 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.000000 370.8 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.000461 342.0 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.0005164 338.8 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.000674 329.7 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.000820 321.5 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.000930 315.6 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.001107 306.5 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.001097 307.0 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.001521 286.7 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.0028003 237.9 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.000000 370.8 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.000461 342.1 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.0005164 338.8 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.000674 329.7 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.000820 321.6 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.000930 315.7 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.001107 306.5 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.001097 307.0 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.001521 286.7 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.0028003 237.9 4.57 Notes

1.

Trhr = temperature - residual heat removal

2.

Tsw = temperature - service water

3.

Heat exchanger original design fouling resistance

4.

The current condition (number of tubes plugged) of each RHR heat exchanger is bounded by the design value of 4.57 percent tubes plugged. Work processes prohibit returning an RHR HX to service following maintenance with more than 4.57 percent tubes plugged without proper design and licensing basis review/evaluation being performed.

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-13 Table 4 Overall Fouling Resistance, K-value and Heat Transfer Rate Summary for Comparison to Heat Exchanger Test Results

SUMMARY

RHR (HX shell side) flow rate (gpm)

RHRSW (HX tube side) flow rate (gpm)

RHR (HX shell side) inlet temperature

(°F)

RHRSW (HX tube side) inlet temperature

(°F)

Assumed Percentage of Tubes Plugged

(%)

Number of RHR HXs in Service (each)

Fouling Resistance Q

per HX K

per HX Q

per HX K

per HX Q

per HX K

per HX Q

per HX K

per HX Q

per HX K

per HX Q

per HX K

per HX (hr-ft2-°F/Btu)

(Btu/hr)

(Btu/sec-°F)

(Btu/hr)

(Btu/sec-°F)

(Btu/hr)

(Btu/sec-°F)

(Btu/hr)

(Btu/sec-°F)

(Btu/hr)

(Btu/sec-°F)

(Btu/hr)

(Btu/sec-°F)

Clean (zero fouling resistance) Heat Transfer Capability 0.000000 100,910,880 334 129,192,588 398 92,196,468 334 149,974,848 366 148,438,656 371 154,846,080 371 RHR HX Demonstrated (Tested) Heat Transfer Capability1 2C (0 years since last cleaning) 0.0004610 93,955,680 311 118,391,400 365 85,845,708 311 138,472,956 338 136,909,440 342 142,860,960 342 3A (2 years since last cleaning) 0.0005164 93,169,440 308 117,191,268 361 85,100,184 308 137,163,132 335 135,628,416 339 141,482,880 339 3C (4 years since last cleaning) 0.000674 90,931,680 301 113,817,924 351 83,056,896 301 133,561,116 326 131,985,504 330 137,682,720 330 2C (4 years since last cleaning) 0.000820 88,905,600 294 110,833,812 342 81,234,504 294 130,286,556 318 128,702,880 322 134,300,160 322 2A (0 years since last cleaning) 0.000930 87,423,840 289 108,660,600 335 79,881,516 289 127,912,500 313 126,340,992 316 131,836,320 316 2A (2 years since last cleaning) 0.001107 85,155,840 282 105,287,256 325 77,783,004 282 124,269,552 304 122,698,080 307 127,994,400 307 EPU Nominal

[Qnominal = QEPUdesign + (Qclean - QEPUdesign)*0.25] then solving for K 128,505,960 308 0.001097 85,276,800 282 105,481,872 325 77,893,452 282 124,474,212 304 122,898,240 307 128,203,200 307 0.001220 76,485,240 277 EPU Design (assuming DBA-LOCA long-term peak suppression pool temperature = 179.0) Heat Transfer Capability 0.001521 80,136,000 265 98,086,464 302 73,199,412 265 116,328,744 284 114,771,744 287 119,725,920 287 0.001856 110,516,400 270 Original Design Heat Transfer Capability 0.002800 67,465,440 223 80,571,024 248 61,629,984 223 96,681,384 236 95,236,128 238 99,347,040 238 1 After accounting for test and measurement uncertainties 7500 7500 DBA-LOCA (RSLB)

Shutdown of Non-Acc Unit ATWS-MSIVC-EOC Fire Event EPU EPU EPU CLTP EPU - with EHPMU Pump EPU - No EHPMU Pump 7500 6500 9700 6500 4500 179.0 185.1 171.7 205.7 206.2 208.0 4000 4500 4000 4400 4500 92.0 4.57 4.57 4.57 4.57 4.57 4.57 95.0 95.0 95.0 92.0 95.0 1

2 1

4 1

1

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-14 Figure 1 RHR Heat Exchanger Fouling Resistances

ATTACHMENT 39 Heat Exchanger K Values Utilized in EPU Containment Analyses

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-1 1.0 Introduction This attachment provides EPU event-specific RHR heat exchanger K-values and heat removal rates for postulated events. The heat exchanger K-value determinations in this attachment confirm that the specific K-value used in each containment analysis is appropriate and suitable for the expected EPU conditions.

The Browns Ferry Nuclear Plant original design value for the RHR heat exchanger effectiveness K-value is 223 BTU/sec-°F.

In Reference 4.3, TVA previously submitted a License Amendment Request (LAR) to transition the licensing basis for the Browns Ferry Nuclear Plant to National Fire Protection Association standard 805 (NFPA 805) which, in (Ref. 4.3) Attachment X and subsequent responses to NRC requests for additional information (RAIs) (Ref. 4.4), included a change to the RHR heat exchanger K-value from 223 BTU/sec-°F to 265 BTU/sec-°F and provided the basis for the change to the K-value. The extended power uprate (EPU) design value used for the containment analyses under the design basis accident (DBA) loss of coolant accident (LOCA),

for containment heat removal is 265 BTU/sec-°F, which is consistent with the NFPA 805 LAR (CLTP) K-value of 265 BTU/sec-°F. However, this EPU LAR attachment also identifies changes to specific values reported in the NFPA 805 LAR. These changes are addressed in the following paragraph.

In the NFPA 805 transition LAR (Ref. 4.3) and associated RAI responses (Ref. 4.4) the RHR heat exchanger overall fouling resistance corresponding to a K-value of 265 BTU/sec-°F and a peak suppression pool temperature of 187.4°F (DBA-LOCA temperature) was reported to be 0.001517 hr-ft2-°F/BTU. This fouling resistance corresponds to a K-value of 284.5 BTU/sec-°F at the CLTP NFPA 805 fire event conditions. However, for conservatism, a K-value of 270 BTU/sec-°F is used in the CLTP NFPA 805 fire event analyses. This attachment provides a re-calculated DBA-LOCA EPU design fouling resistance associated with a K-value of 265 BTU/sec-°F for a peak suppression pool temperature of 179.0°F. This change in the peak suppression pool temperature from 187.4°F to 179.0°F results in a slightly different EPU design fouling resistance, 0.001521 hr-ft2-°F/BTU. The values of DBA-LOCA peak suppression pool temperature and design fouling resistance that were provided in the NFPA 805 LAR (Ref. 4.3) are superseded by the EPU values provided herein, 179.0°F and 0.001521 hr-ft2-°F/BTU, respectively, and reflect updated EPU analyses.

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-2 EPU licensing basis RHR heat exchanger K-values are as follows:

EPU event K-value (BTU/sec-°F)

DBA-LOCA 265 Small Break LOCA 265 Loss of Shutdown Cooling 265 Stuck Open Relief Valve 265 Station Blackout (SBO) 265 ATWS 277 Shutdown of Non-Accident Unit 302 Fire 307*

  • In addition, the fire event was analyzed using the Emergency High Pressure Make-Up (EHPMU) pump and an RHR heat exchanger K-value of 287 BTU/sec-°F. This represents a defense-in-depth demonstration and is not a licensing basis analysis.

The Browns Ferry Nuclear Plant Updated Final Safety Analysis Report (UFSAR) (Ref. 4.5) provides additional descriptive information concerning the Residual Heat Removal (RHR) heat exchangers in UFSAR sections 1.6.2.12 (Residual Heat Removal System (Containment Cooling)), 4.8.6.2 (Containment Cooling), 4.8.6.3 (Low Pressure Coolant Injection), Table 4.8-1 (Residual Heat Removal System Equipment Design Data) and Table 5.2-1 (Principal Design Parameters and Characteristics of Primary Containment).

2.0 Computations and Analysis 2.1 Methodology The methodology utilizes an Excel spreadsheet platform, and standard engineering formulas, to solve for the RHR heat exchanger K-value based on the input parameter values.

The formula for heat exchanger effectiveness is a function of the overall heat transfer coefficient, the effective heat transfer area, and other parameters identified below. The Browns Ferry Nuclear Plant RHR heat exchangers are identical single shell pass, two tube pass Tubular Exchanger Manufacturers Association, Inc. (TEMA) type CES heat exchangers. The effectiveness for this type heat exchanger is:

(

)

(

)

(

)

1 1

1 5.0 5.0 2

5.0 2

2 1

1 1

1 2

+

+

+

+

+

+

=

R R

C NTU C

NTU R

R e

e C

C e

(Equation 1 - Ref. 4.1)

Where:

e

= heat exchanger effectiveness CR

= heat capacity ratio

= Cmin/Cmax

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-3 Cmin = minimum mass flow rate times fluid heat capacity product, BTU/hr-oF Cmax = maximum mass flow rate times fluid heat capacity product, BTU/hr-oF NTU

= number of transfer units

= UA/Cmin U

= overall heat transfer coefficient, BTU/hr-ft2-°F A

= effective heat transfer area, ft2 Equation 1 was used to determine fouling resistance and/or K-values for various state points for the analyzed event sequences.

Tables 1, 2, and 3, below, provide the results from specific evaluations using the overall fouling resistance and the corresponding heat exchanger K-value for each of the fouling resistances in Table 4. The specified fouling resistances cover a wide range from the original supplied RHR heat exchanger design fouling resistance (0.002800 hr-ft2-°F/BTU) to a clean RHR heat exchanger fouling resistance (0.000000 hr-ft2-°F/BTU). Specifically, the EPU design fouling resistance, 0.001521 hr-ft2-°F/BTU; the EPU nominal fouling resistance, 0.001097 hr-ft2-°F/BTU and the fouling resistances determined from six different Browns Ferry Nuclear Plant RHR heat exchanger tests performed to date are some of the more significant fouling resistances.

Table 4 provides a comparison summary of heat exchanger heat transfer rates and corresponding K-values for the different EPU K-values used in the event analyses:

  • 265 BTU/sec-°F (DBA-LOCA, Small Break LOCA, Loss of Shutdown Cooling, Stuck Open Relief Valve and SBO), 302 BTU/sec-°F (Shutdown of Non-Accident Unit), and 287 BTU/sec-°F (fire event defense-in-depth demonstration case) are based on the EPU design fouling resistance, 0.001521 hr-ft2-°F/BTU.
  • 307 BTU/sec-°F (fire event licensing basis) is based on the EPU nominal fouling resistance, 0.001097 hr-ft2-°F/BTU.
  • 277 BTU/sec-°F for the ATWS-MSIVC-EOC event corresponds to a nominal fouling resistance of 0.001220 hr-ft2-°F/BTU.

2.2 Analysis RHR heat exchanger K-values used in the containment analyses are identified for each event within the applicable Browns Ferry Nuclear Plant Power Uprate Safety Analysis Report (PUSAR) section. Unless otherwise noted and discussed below for ATWS and fire events, all events were evaluated at the EPU design fouling resistance (same heat exchanger material condition). For the same EPU design fouling resistance, differences in RHR and Residual Heat Removal Service Water (RHRSW) flow rates from one event to another may result in different RHR heat exchanger K-values (see Table 4).

The DBA LOCA discussion provides the basis for the change in the pre-EPU and the EPU design fouling resistance and the corresponding EPU K-value of 265 BTU/sec-°F. The Shutdown of the Non-Accident Unit analysis K-value is also based on the EPU design fouling resistance, 0.001521 hr-ft2-°F/BTU. The EPU fire event analysis K-value was based on the EPU nominal fouling resistance, 0.001097 hr-ft2-°F/BTU and the ATWS event analyses were based on a nominal fouling resistance or K-value that lies between the EPU design and EPU nominal fouling resistances. Details are provided in the following discussion of the events.

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-4 DBA-LOCA - PUSAR Section 2.6.5.1 The EPU design basis fouling resistance is based on the conditions from the EPU DBA-LOCA. Specifically, the RHR flow rate of 6500 gpm at a peak suppression pool temperature (heat exchanger inlet temperature) of 179.0°F, RHRSW flow rate of 4000 gpm at 95°F RHRSW temperature, with up to 4.57 percent tube plugging, and an RHR heat exchanger K-value of 265 BTU/sec-°F are used to determine the EPU design basis fouling resistance.

Equation 1 is used to solve for fouling resistance, based on a given K-value or, to calculate a K-value based on a specified fouling resistance, provided the other state points are known.

The EPU containment response analyses were performed for the long-term DBA-LOCA using a RHR heat exchanger K-value of 265 BTU/sec-°F compared to 223 BTU/sec-°F used in previous analyses. The previous value of 223 BTU/sec-°F was based on the RHR heat exchanger specification sheets, which specified the design fouling resistances. Browns Ferry Nuclear Plant plant-specific RHR heat exchanger testing (Ref. 4.4, including SCVB RAI-5) has shown there is substantial margin between the design and actual (tested) heat exchanger fouling resistances.

Some of this large margin was used to increase RHR heat exchanger heat transfer capability from that specified in the original design to a K-value of 265 BTU/sec-°F. The corresponding EPU design fouling resistance at the DBA-LOCA conditions identified above is 0.001521 hr-ft2-°F/BTU.

Under certain scenarios, higher RHR and/or RHRSW flows may be achieved than those used to establish the EPU design basis fouling resistance. Using minimum flow rates in determining the RHR heat exchanger heat removal capability embeds conservatism into the containment analysis results. A lower containment heat removal rate results in higher suppression pool temperatures; thus, the analysis is conservative with respect to suppression pool temperature.

Other events, including the small break LOCA, loss of RHR shutdown cooling, stuck open relief valve (SORV), and station blackout, were evaluated using an RHR heat exchanger K-value of 265 BTU/sec-°F and are described in PUSAR Section 2.6.5.2.

Shutdown of the Non-Accident Unit - PUSAR Section 2.6.5.1 An RHR heat exchanger K-value of 302 BTU/sec-°F was used in the analysis of the shutdown of the non-accident unit. This value represents the K-value resulting from a design basis fouling resistance, RHR flow of 9700 gpm at the peak suppression pool temperature of 185.1°F, RHRSW flow of 4500 gpm at 95°F, and 4.57 percent tube plugging. These parameters are consistent with the analysis inputs/results described in PUSAR Section 2.6.5.1.

Fire Event - PUSAR Section 2.5.1.4.2 The fire event analysis assumes one RHR heat exchanger available for event mitigation. All other RHR heat exchangers are assumed to be not available which restricts containment heat removal capability. Of all the events analyzed, because of restrictive/conservative assumptions, such as the availability of only one RHR pump and heat exchanger, the fire event results in the highest peak suppression pool temperature. In-situ RHR heat exchanger performance testing (results previously submitted under Browns Ferry Nuclear Plant

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-5 NFPA 805 LAR (Ref. 4.3) Attachment X and associated RAI responses (Ref. 4.4))

demonstrate that the actual heat removal capability of RHR heat exchangers exceeds that assumed in the fire event containment analysis.

An RHRSW flow of 4500 gpm is achievable for the fire event. The combination of increased RHRSW flow and the use of a realistic or nominal heat exchanger fouling resistance, 0.001097 hr-ft2-°F/BTU, corresponds to an increase in the EPU fire event heat exchanger K-value to 307 BTU/sec-°F. As discussed in PUSAR Section 2.5.1.4.2, a fire event containment analysis was performed using the K-value of 307 BTU/sec-°F which resulted in a peak suppression pool temperature of 208.0°F.

SECY-11-0014 (Ref. 4.8) provides guidance on the use of realistic or nominal inputs for special events such as a fire event. For the Browns Ferry Nuclear Plant EPU, when a nominal K-value was selected or established, the heat exchanger test data available for comparison to the selected realistic or nominal value was limited to that reported in the NFPA 805 LAR (Ref. 4.3) Attachment X and associated RAI responses (Ref. 4.4). These reported as tested fouling resistances of 0.0005164 and 0.000674 hr-ft2-°F/BTU, are shown on Figure 1, and resulted in a large difference between the test results and the EPU design (0.001521 hr-ft2-°F/BTU) fouling resistance. To provide confidence in establishing a reasonable realistic or nominal heat exchanger fouling resistance, industry literature was consulted for establishing the realistic or nominal fouling resistance.

EPRI Test Report 107397, Service Water Heat Exchanger Testing Guidelines, (Ref. 4.2) section 3.4.2 provides guidance in establishing an acceptance criterion for test uncertainty to determine whether a given test result is acceptable. The guidance suggests that an initial acceptance criterion can be established in terms of the heat transfer rate, at +/- 25 percent of the difference between the design and clean (zero fouling resistance) heat transfer rates.

This provided a reasonable bound for establishing the expected deviation from a design heat transfer rate to an actual or tested heat transfer rate. The realistic or nominal fouling resistance was determined by taking 25 percent of the difference between the EPU fire event design heat transfer rate and the clean heat transfer rate and adding that to the EPU design heat transfer rate to obtain the heat transfer rate corresponding to the realistic or nominal fouling resistance. The results of this computation are provided in Table 4 where this process was followed to determine the fire event K-value, 308 BTU/sec-°F. The value chosen for the RHR heat exchanger fire event nominal K-value was 307 BTU/sec-°F, which is within the range from 287 BTU/sec-°F (EPU design) to 308 BTU/sec-°F.

The nominal fire event K-value of 307 BTU/sec-°F represents an approximate 7 percent increase from the EPU fire event design K-value of 287 BTU/sec-°F (computed using the EPU design fouling resistance, 0.001521 hr-ft2-°F/BTU, 7500 gpm RHR flow at 208.0°F, 4500 gpm RHRSW flow at 92.0°F and 4.57 percent of the tubes plugged). This approximate 7 percent increase in the EPU fire event design K-value to the EPU fire event nominal K-value compared well with an NRC staff assessment (Ref. 4.6) where conservative and realistic RHR heat exchanger K-values were determined and compared at 147 and 158 BTU/sec-°F, respectively. The increase from 147 BTU/sec-°F to 158 BTU/sec-°F constitutes an approximate 7.5 percent increase in the conservative or design basis K-value, which compares well to the Browns Ferry Nuclear Plant 7 percent increase described above.

Using the nominal fire event K-value of 307 BTU/sec-°F, Equation 1 was used to solve for the resulting EPU nominal fire event fouling resistance, 0.001097 hr-ft2-°F/BTU (see Table 3). This fouling resistance is used for comparison to Browns Ferry Nuclear Plant RHR

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-6 heat exchanger test results graphically presented in Figure 1. Figure 1 provides the results from the tests performed to date.

Comparison of the Browns Ferry Nuclear Plant RHR heat exchanger test results to the EPU design and nominal fouling resistances shown in Figure 1 leads to two clear observations:

(1) the results from the 2A RHR heat exchanger as-found test (two years since last cleaning) closely match the EPU fire event nominal fouling resistance and, (2) the 2A RHR heat exchanger as-left test results (0 years since last cleaning) when compared with the 2A RHR heat exchanger as-found test results and the other three heat exchanger test results show that the 2A RHR heat exchanger performance, when expressed in terms of fouling resistance, is not as good as the other heat exchangers. These (identical in design) heat exchangers when subjected to identical operating conditions would be expected to demonstrate essentially identical performance; however, the as-tested performance of the 2A RHR heat exchanger differs from that of the other heat exchangers. This apparent anomalous performance of the 2A RHR heat exchanger has been entered into the Browns Ferry Nuclear Plant corrective action program to identify the condition and evaluate the issue to resolution.

The difference between the RHR heat exchanger test results (including the 2A RHR heat exchanger) and the EPU design fouling resistance serves to demonstrate the conservatism embedded in the event analyses where the RHR heat exchanger K-value is determined from the EPU design fouling resistance.

The difference between the RHR heat exchanger test results (excluding the 2A RHR heat exchanger) and the EPU fire event nominal fouling resistance serves to demonstrate that the EPU fire event nominal fouling resistance is appropriate for use in fire event analyses.

The fire event sensitivity case with the EHPMU pump reported in PUSAR Section 2.6.5.2, PUSAR Tables 2.6-4 and 2.6-4a did not use a realistic or nominal heat exchanger fouling resistance but instead used a K-value, 287 BTU/sec-°F, corresponding to the EPU design fouling resistance, 0.001521 hr-ft2-°F/BTU. The sensitivity case demonstrates defense-in-depth for a fire event.

The current licensed thermal power (CLTP) analysis in Table 4 summarizes the fire event analysis parameters and the K-value used in the analysis submitted in the NFPA 805 LAR.

As indicated in Table 4, the CLTP NFPA 805 analysis was performed assuming 4400 gpm RHRSW flow and an RHR heat exchanger K-value of 270 BTU/sec-°F. For EPU the RHRSW flow rate is 4500 gpm and the RHR heat exchanger K-value is 307 BTU/sec-°F, as discussed above. No modifications are required to effect the change in the RHRSW flow rate from 4400 gpm to 4500 gpm as the CLTP analysis was performed using a conservatively low flow rate compared to the actual RHRSW flow capability during a fire.

Anticipated Transient Without Scram (ATWS) - PUSAR Sections 2.6.5.2 and 2.8.5.7 The limiting ATWS event with respect to peak suppression pool temperature is the ATWS loss-of-offsite power (LOOP) event (two RHR pumps and two RHR heat exchangers credited) which resulted in a peak suppression pool temperature of 173.3°F. The most limiting non-LOOP (four RHR pumps and four RHR heat exchangers credited) ATWS event is the Main Steam Isolation Valve Closure-End of Cycle (MSIVC-EOC) event which experiences a peak suppression pool temperature of approximately 171.7°F. When the combined transient effects of pool temperature, pool level and pump suction losses are

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-7 considered, the limiting ATWS event from a net positive suction head (NPSH) perspective is a non-LOOP event (MSIVC-EOC). For Browns Ferry Nuclear Plant EPU ECCS pump NPSH, MSIVC-EOC remains the most limiting ATWS event.

An RHR heat exchanger K-value of 277 BTU/sec-°F was used in each ATWS analysis. The K-value corresponds to an RHRSW temperature of 95°F, 4500 gpm RHRSW flow, RHR (heat exchanger shell inlet) temperature of 173.3°F (peak suppression pool temperature for ATWS-LOOP event as discussed in PUSAR Sections 2.6.5.2 and 2.8.5.7.2),

6500 gpm RHR flow and 4.57 percent tube plugging, at the EPU design fouling resistance, 0.001521 hr-ft2-°F/BTU, is 277.8 BTU/sec-°F. These conditions are applicable for the ATWS-LOOP event where only two heat exchangers in the ATWS unit are credited with mitigating the event.

Where four RHR heat exchangers in the same unit are credited with mitigating the ATWS event, system hydraulic resistances in common RHRSW piping on the discharge side of the RHR heat exchangers and in the discharge piping where the two loops combine into common piping, results in the RHRSW flow being restricted such that only 4000 gpm is passed through each of the four heat exchangers. This explains the reduction in the RHRSW flow rate per heat exchanger from 4500 gpm per heat exchanger in the two heat exchanger alignment described above, to 4000 gpm per heat exchanger in the four heat exchanger alignment. The effect of this condition on the EPU ATWS analyses is described below.

The analyses K-value of 277 BTU/sec-°F used in the non-LOOP ATWS events, corresponds to a fouling resistance of 0.001220 hr-ft2-°F/BTU. This was determined using Equation 1 with RHRSW temperature at 95°F, 4000 gpm RHRSW flow, RHR (heat exchanger shell inlet) temperature of 171.7°F, 6500 gpm RHR flow, and 4.57 percent tube plugging. This reduced fouling resistance of 0.001220 hr-ft2-°F/BTU is justified because it is conservative relative to the EPU nominal fouling resistance of 0.001097 hr-ft2-°F/BTU (see Figure 1). In addition, the difference between the RHR heat exchanger test results (including the 2A RHR heat exchanger) and this reduced fouling resistance value serves to demonstrate that this fouling resistance value is appropriate for use in ATWS event analyses.

2.3 RHR Heat Exchanger Performance Monitoring In Attachment X,Section X.4 of Reference 4.3, TVA stated that the Browns Ferry Nuclear Plant RHR heat exchangers would be subject to a performance monitoring program to provide assurance that heat exchanger fouling that could affect the required heat transfer rate is detected and corrected in a timely manner. Reference 4.7 also included a commitment (i.e., Commitment 2) to implement a heat exchanger monitoring program to provide assurance that the RHR heat exchanger performance is maintained for consistency with analytical assumptions associated with the adoption of the NFPA 805 standard.

Because the revised performance monitoring program has not been developed at this time, the commitment specifies implementation within six months following NRC issuance of the license amendment approving adoption of the NFPA 805 standard for the Browns Ferry Nuclear Plant. In addition, TVA will revise the program that monitors Browns Ferry Nuclear Plant RHR heat exchanger performance for consistency with the assumptions used in analyses supporting EPU prior to EPU license amendment implementation. TVA intends to include, as requirements in the program, periodic heat exchanger inspections and heat exchanger performance testing requirements to ensure fouling factor assumptions and tube plugging assumptions in the EPU containment analyses remain valid.

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-8 3.0 Summary and Conclusion Based on the analyses described above, the RHR heat exchanger fouling resistances and K-values used in the EPU event analyses are appropriate:

  • The EPU design fouling resistance is 0.001521 hr-ft2-°F/BTU. This was determined using a heat exchanger K-value of 265 BTU/sec-°F with an RHR flow rate of 6500 gpm at RHR (heat exchanger shell side inlet) temperature of 179.0°F, RHRSW flow rate of 4000 gpm at RHRSW inlet temperature of 95°F with 4.57 percent tubes plugged;
  • The EPU nominal fouling resistance is 0.001097 hr-ft2-°F/BTU; and
  • RHR heat exchanger as-found test results demonstrate the EPU design and nominal fouling resistance values are appropriate for use in the associated event analyses.

In addition, periodic RHR heat exchanger performance testing will be used to demonstrate that actual heat exchanger performance exceeds the performance credited in the analyses.

4.0 References 4.1 Fundamentals of Heat and Mass Transfer by Frank P. Incropera and David P. Dewitt, John Wiley & Sons, 3rd Edition, 1990 4.2 EPRI Test Report 107397, Service Water Heat Exchanger Testing Guidelines, Electric Power Research Institute, March 1998 4.3 TVA Letter to NRC, License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants (2001 Edition) (Technical Specification Change TS-480), March 27, 2013 (ADAMS Accession Number ML13092A392) 4.4 TVA Letter to NRC, Response to NRC Request for Additional Information Regarding the License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants for the Browns Ferry Nuclear Plant, Units 1, 2, and 3 (TAC Nos. MF1185, MF1186, and MF1187) -

Attachment X and Fire Modeling, June 13, 2014 (ADAMS Accession Number ML14167A175) 4.5 Browns Ferry Nuclear Plant Updated Safety Analysis Report, Sections 1.6.2.12, 4.8.6.2, 4.8.6.3, Table 4.8-1, and Table 5.2-1 4.6 NRC Memorandum to ACRS Members, Certification of the Meeting Minutes from the Advisory Committee on Reactor Safeguards 572nd Full Committee Meeting Held on May 6-8 2010 in Rockville, Maryland, August 16, 2010 (ADAMS Accession Number ML101830190) 4.7 TVA Letter to NRC, Response to NRC Request to Supplement License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants for the Browns Ferry Nuclear Plant, Units 1, 2, and 3 (TAC Nos. MF1185, MFl186, and MF1187), May 16, 2013 (ADAMS Accession Number ML13141A291)

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-9 4.8 SECY-11-0014 - Use of Containment Accident Pressure in Analyzing Emergency Core Cooling System and Containment Heat Removal System Pump Performance in Postulated Accidents, U.S. Nuclear Regulatory Commission, January 31, 2011, (ADAMS Accession No. ML102590196)

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-10 Table 1 Overall Fouling Resistances and K-values for Events with RHR Flow Rate 6500 gpm Event Trhr2 Tsw3 RHRSW Flow Overall Fouling Resistance K

Tube Plugging5 F

F gpm hr-ft2-°F/Btu Btu/sec-°F percent DBA-LOCA (RSLB1) 179.0 95 4000 0.000000 333.7 4.57 DBA-LOCA (RSLB) 179.0 95 4000 0.000461 310.7 4.57 DBA-LOCA (RSLB) 179.0 95 4000 0.0005164 308.1 4.57 DBA-LOCA (RSLB) 179.0 95 4000 0.000674 300.7 4.57 DBA-LOCA (RSLB) 179.0 95 4000 0.000820 294.0 4.57 DBA-LOCA (RSLB) 179.0 95 4000 0.000930 289.1 4.57 DBA-LOCA (RSLB) 179.0 95 4000 0.001107 281.6 4.57 DBA-LOCA (RSLB) 179.0 95 4000 0.001097 282.0 4.57 DBA-LOCA (RSLB) 179.0 95 4000 0.001521 265.0 4.57 DBA-LOCA (RSLB) 179.0 95 4000 0.0028004 223.1 4.57 ATWS-LOOP 173.3 95 4500 0.000000 355.6 4.57 ATWS-LOOP 173.3 95 4500 0.000461 329.2 4.57 ATWS-LOOP 173.3 95 4500 0.0005164 326.2 4.57 ATWS-LOOP 173.3 95 4500 0.000674 317.8 4.57 ATWS-LOOP 173.3 95 4500 0.000820 310.3 4.57 ATWS-LOOP 173.3 95 4500 0.000930 304.8 4.57 ATWS-LOOP 173.3 95 4500 0.001107 296.3 4.57 ATWS-LOOP 173.3 95 4500 0.001097 296.8 4.57 ATWS-LOOP 173.3 95 4500 0.001521 277.8 4.57 ATWS-LOOP 173.3 95 4500 0.0028004 231.9 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.000000 333.9 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.000461 310.9 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.0005164 308.2 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.000674 300.8 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.000820 294.2 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.000930 289.3 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.001107 281.7 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.001097 282.1 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.001220 277.0 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.001521 265.1 4.57 ATWS-MSIVC EOC 171.7 95 4000 0.0028004 223.2 4.57 Notes

1.

RSLB = recirculation suction line break

2.

Trhr = temperature - residual heat removal

3.

Tsw = temperature - service water

4.

Heat exchanger original design fouling resistance

5. The current condition (number of tubes plugged) of each RHR heat exchanger is bounded by the design value of 4.57 percent tubes plugged. Work processes prohibit returning an RHR heat exchanger (HX) to service following maintenance with more than 4.57 percent tubes plugged without proper design and licensing basis review/evaluation being performed.

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-11 Table 2 Overall Fouling Resistances and K-values for Events with RHR Flow Rate 9700 gpm Event Trhr1 Tsw2 RHRSW Flow Overall Fouling Resistance K

Tube Plugging4 F

F gpm hr-ft2-°F/Btu Btu/sec-°F percent Shutdown of Non-Accident Unit 185.1 95 4500 0.000000 398.3 4.57 Shutdown of Non-Accident Unit 185.1 95 4500 0.000461 365.0 4.57 Shutdown of Non-Accident Unit 185.1 95 4500 0.0005164 361.3 4.57 Shutdown of Non-Accident Unit 185.1 95 4500 0.000674 350.9 4.57 Shutdown of Non-Accident Unit 185.1 95 4500 0.000820 341.7 4.57 Shutdown of Non-Accident Unit 185.1 95 4500 0.000930 335.0 4.57 Shutdown of Non-Accident Unit 185.1 95 4500 0.001107 324.6 4.57 Shutdown of Non-Accident Unit 185.1 95 4500 0.001097 325.2 4.57 Shutdown of Non-Accident Unit 185.1 95 4500 0.001521 302.4 4.57 Shutdown of Non-Accident Unit 185.1 95 4500 0.0028003 248.4 4.57 Notes

1.

Trhr = temperature - residual heat removal

2.

Tsw = temperature - service water

3.

Heat exchanger original design fouling resistance

4. The current condition (number of tubes plugged) of each RHR heat exchanger is bounded by the design value of 4.57 percent tubes plugged. Work processes prohibit returning an RHR HX to service following maintenance with more than 4.57 percent tubes plugged without proper design and licensing basis review/evaluation being performed.

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-12 Table 3 Overall Fouling Resistance and K-values for Events with RHR Flow Rate 7500 gpm Event Trhr1 Tsw2 RHRSW Flow Overall Fouling Resistance K

Tube Plugging4 F

F gpm hr-ft2-°F/Btu Btu/sec-°F percent FIRE - CLTP 205.7 92 4400 0.000000 366.4 4.57 FIRE - CLTP 205.7 92 4400 0.000461 338.3 4.57 FIRE - CLTP 205.7 92 4400 0.0005164 335.1 4.57 FIRE - CLTP 205.7 92 4400 0.000674 326.3 4.57 FIRE - CLTP 205.7 92 4400 0.000820 318.3 4.57 FIRE - CLTP 205.7 92 4400 0.000930 312.5 4.57 FIRE - CLTP 205.7 92 4400 0.001107 303.6 4.57 FIRE - CLTP 205.7 92 4400 0.001097 304.1 4.57 FIRE - CLTP 205.7 92 4400 0.001521 284.2 4.57 FIRE - CLTP 205.7 92 4400 0.001856 270.0 4.57 FIRE - CLTP 205.7 92 4400 0.0028003 236.2 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.000000 370.8 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.000461 342.0 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.0005164 338.8 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.000674 329.7 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.000820 321.5 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.000930 315.6 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.001107 306.5 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.001097 307.0 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.001521 286.7 4.57 FIRE - EPU with EHPMU pump 206.2 95 4500 0.0028003 237.9 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.000000 370.8 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.000461 342.1 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.0005164 338.8 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.000674 329.7 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.000820 321.6 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.000930 315.7 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.001107 306.5 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.001097 307.0 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.001521 286.7 4.57 FIRE - EPU - No EHPMU pump 208.0 92 4500 0.0028003 237.9 4.57 Notes

1.

Trhr = temperature - residual heat removal

2.

Tsw = temperature - service water

3.

Heat exchanger original design fouling resistance

4.

The current condition (number of tubes plugged) of each RHR heat exchanger is bounded by the design value of 4.57 percent tubes plugged. Work processes prohibit returning an RHR HX to service following maintenance with more than 4.57 percent tubes plugged without proper design and licensing basis review/evaluation being performed.

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-13 Table 4 Overall Fouling Resistance, K-value and Heat Transfer Rate Summary for Comparison to Heat Exchanger Test Results

SUMMARY

RHR (HX shell side) flow rate (gpm)

RHRSW (HX tube side) flow rate (gpm)

RHR (HX shell side) inlet temperature

(°F)

RHRSW (HX tube side) inlet temperature

(°F)

Assumed Percentage of Tubes Plugged

(%)

Number of RHR HXs in Service (each)

Fouling Resistance Q

per HX K

per HX Q

per HX K

per HX Q

per HX K

per HX Q

per HX K

per HX Q

per HX K

per HX Q

per HX K

per HX (hr-ft2-°F/Btu)

(Btu/hr)

(Btu/sec-°F)

(Btu/hr)

(Btu/sec-°F)

(Btu/hr)

(Btu/sec-°F)

(Btu/hr)

(Btu/sec-°F)

(Btu/hr)

(Btu/sec-°F)

(Btu/hr)

(Btu/sec-°F)

Clean (zero fouling resistance) Heat Transfer Capability 0.000000 100,910,880 334 129,192,588 398 92,196,468 334 149,974,848 366 148,438,656 371 154,846,080 371 RHR HX Demonstrated (Tested) Heat Transfer Capability1 2C (0 years since last cleaning) 0.0004610 93,955,680 311 118,391,400 365 85,845,708 311 138,472,956 338 136,909,440 342 142,860,960 342 3A (2 years since last cleaning) 0.0005164 93,169,440 308 117,191,268 361 85,100,184 308 137,163,132 335 135,628,416 339 141,482,880 339 3C (4 years since last cleaning) 0.000674 90,931,680 301 113,817,924 351 83,056,896 301 133,561,116 326 131,985,504 330 137,682,720 330 2C (4 years since last cleaning) 0.000820 88,905,600 294 110,833,812 342 81,234,504 294 130,286,556 318 128,702,880 322 134,300,160 322 2A (0 years since last cleaning) 0.000930 87,423,840 289 108,660,600 335 79,881,516 289 127,912,500 313 126,340,992 316 131,836,320 316 2A (2 years since last cleaning) 0.001107 85,155,840 282 105,287,256 325 77,783,004 282 124,269,552 304 122,698,080 307 127,994,400 307 EPU Nominal

[Qnominal = QEPUdesign + (Qclean - QEPUdesign)*0.25] then solving for K 128,505,960 308 0.001097 85,276,800 282 105,481,872 325 77,893,452 282 124,474,212 304 122,898,240 307 128,203,200 307 0.001220 76,485,240 277 EPU Design (assuming DBA-LOCA long-term peak suppression pool temperature = 179.0) Heat Transfer Capability 0.001521 80,136,000 265 98,086,464 302 73,199,412 265 116,328,744 284 114,771,744 287 119,725,920 287 0.001856 110,516,400 270 Original Design Heat Transfer Capability 0.002800 67,465,440 223 80,571,024 248 61,629,984 223 96,681,384 236 95,236,128 238 99,347,040 238 1 After accounting for test and measurement uncertainties 7500 7500 DBA-LOCA (RSLB)

Shutdown of Non-Acc Unit ATWS-MSIVC-EOC Fire Event EPU EPU EPU CLTP EPU - with EHPMU Pump EPU - No EHPMU Pump 7500 6500 9700 6500 4500 179.0 185.1 171.7 205.7 206.2 208.0 4000 4500 4000 4400 4500 92.0 4.57 4.57 4.57 4.57 4.57 4.57 95.0 95.0 95.0 92.0 95.0 1

2 1

4 1

1

BFN EPU LAR Attachment 39 RHR Heat Exchanger K-values Utilized in EPU Containment Analyses Att 39-14 Figure 1 RHR Heat Exchanger Fouling Resistances