Letter Sequence Other |
---|
|
Results
Other: ML15147A056, ML15253A721, RC-13-0031, Integrated Plan with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051), RC-13-0117, 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation, RC-15-0031, Fourth 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation, RC-15-0125, Fifth Six-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049), RC-15-0126, Fifth 6-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051)
|
MONTHYEARRC-13-0031, Integrated Plan with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051)2013-02-28028 February 2013 Integrated Plan with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051) Project stage: Other RC-13-0109, Online Reference Portal for Review of Mitigation Strategies, Submittal in Response to Order EA-12-0492013-07-26026 July 2013 Online Reference Portal for Review of Mitigation Strategies, Submittal in Response to Order EA-12-049 Project stage: Other ML13203A1802013-07-29029 July 2013 Request for Additional Information Regarding Overall Integrated Plan for Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051) Project stage: RAI RC-13-0119, Transmittal of Figures Associated with South Carolina Electric & Gas Company Response to the NRC Request for Additional Information Regarding the VCSNS Overall Integrated Plan (RC-13-0119)2013-08-13013 August 2013 Transmittal of Figures Associated with South Carolina Electric & Gas Company Response to the NRC Request for Additional Information Regarding the VCSNS Overall Integrated Plan (RC-13-0119) Project stage: Request ML13247A3382013-08-28028 August 2013 Response to Request for Additional Information - Overall Integrated Plan to Commission Order Modifying License Requirements for Reliable Spent Fuel Pool Instrumentation (Order No. EA-12-051) Project stage: Response to RAI RC-13-0123, V. C. Summer, Unit 1 - First Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order No. EA-12-049)2013-08-28028 August 2013 V. C. Summer, Unit 1 - First Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order No. EA-12-049) Project stage: Other RC-13-0117, 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation2013-08-28028 August 2013 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation Project stage: Other ML13305A1002013-12-0505 December 2013 Interim Staff Evaluation and Request for Additional Information Regarding the Overall Integrated Plan for Implementation of Order EA-12-051, Reliable Spent Fuel Pool Instrumentation Project stage: RAI ML14034A3392014-02-21021 February 2014 Interim Staff Evaluation Relating to Overall Integrated Plan in Response to Order EA-12-049 (Mitigation Strategies) Project stage: Acceptance Review ML14037A2282014-02-21021 February 2014 Mega-Tech Services, LLC Technical Evaluation Report Regarding the Overall Integrated Plan for Virgil C. Summer Nuclear Station, Unit 1, TAC MF2338 Project stage: Other ML14056A0672014-02-21021 February 2014 Fifth Batch SE Final Revision 3- 1 Site (VC Summer) Project stage: Other RC-14-0030, South Carolina Electric & Gas Company'S Second Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External..2014-02-27027 February 2014 South Carolina Electric & Gas Company'S Second Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External.. Project stage: Other RC-14-0144, Third Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-04)2014-08-28028 August 2014 Third Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-04) Project stage: Other RC-15-0031, Fourth 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation2015-02-27027 February 2015 Fourth 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation Project stage: Other RC-15-0030, Fourth Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events.2015-02-27027 February 2015 Fourth Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events. Project stage: Other ML15147A0562015-06-0202 June 2015 Plan for the Onsite Audit Regarding Implementation of Mitigating Strategies and Reliable Spent Fuel Instrumentation Related to Orders EA-12-049 and EA-12-051 Project stage: Other RC-15-0117, Request for Schedule Relaxation from NRC Order EA-12-049, Issuance of Order to Modify Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events.2015-08-13013 August 2015 Request for Schedule Relaxation from NRC Order EA-12-049, Issuance of Order to Modify Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events. Project stage: Request RC-15-0126, Fifth 6-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051)2015-08-20020 August 2015 Fifth 6-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051) Project stage: Other RC-15-0125, Fifth Six-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049)2015-08-24024 August 2015 Fifth Six-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049) Project stage: Other ML15253A7212015-09-16016 September 2015 Report for the Onsite Audit Regarding Implementation of Mitigating Strategies and Reliable Spent Fuel Instrumentation Related to Orders EA-12-049 and EA-12-051 Project stage: Other ML15243A4502015-10-0404 October 2015 Relaxation of the Schedule Requirements of Order EA-12 049 Issuance of Order T Modify Licenses with Regard to Requirements for Mitigation Strategies for Beyond Design Basis External Events Project stage: Approval RC-16-0001, V.C. Summer, Report of Full Compliance with March 12, 2012, Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051) and Responses to Requests for Additional Information2016-01-22022 January 2016 V.C. Summer, Report of Full Compliance with March 12, 2012, Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051) and Responses to Requests for Additional Information Project stage: Response to RAI RC-16-0028, Notification of an Intended Changed to a Commitment Date for Response to Request for Additional Information Regarding Phase 2 Staffing Submittals Associated with Near-Term Task Force Recommendation 9.3 Related to the Fukushima..2016-02-26026 February 2016 Notification of an Intended Changed to a Commitment Date for Response to Request for Additional Information Regarding Phase 2 Staffing Submittals Associated with Near-Term Task Force Recommendation 9.3 Related to the Fukushima.. Project stage: Response to RAI 2014-08-28
[Table View] |
|
---|
Category:Letter type:RC
MONTHYEARRC-22-0004, (Vcsns), Unit 1 - 2021 Annual Letter of Certification and Testing Results of the Public Alerting System2022-01-14014 January 2022 (Vcsns), Unit 1 - 2021 Annual Letter of Certification and Testing Results of the Public Alerting System RC-18-0157, (Vcsns), Units 1, 2 and 3 Independent Spent Fuel Storage Installation - Order Approving Indirect Transfer of Control of Operating License and Combined Licenses2018-12-28028 December 2018 (Vcsns), Units 1, 2 and 3 Independent Spent Fuel Storage Installation - Order Approving Indirect Transfer of Control of Operating License and Combined Licenses RC-18-0149, ISFSI - Order Approving Indirect Transfer of Control of Operating License and Combined Licenses2018-12-21021 December 2018 ISFSI - Order Approving Indirect Transfer of Control of Operating License and Combined Licenses RC-18-0136, (Vcsns), Unit 1 - Request to Remove the Expired One-Time Extension to Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation and to Remove the Index from Technical Specifications (LAR-18-04683)2018-12-12012 December 2018 (Vcsns), Unit 1 - Request to Remove the Expired One-Time Extension to Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation and to Remove the Index from Technical Specifications (LAR-18-04683) RC-18-0144, (Vcsns), Unit 1 - Core Operating Limits Report (COLR) for Cycle 252018-11-20020 November 2018 (Vcsns), Unit 1 - Core Operating Limits Report (COLR) for Cycle 25 RC-18-0126, (Vcsns), Unit 1 - Notification of an Intended Change a Commitment Date for Open Phase Condition (OPC) Made in RC-17-01692018-11-0909 November 2018 (Vcsns), Unit 1 - Notification of an Intended Change a Commitment Date for Open Phase Condition (OPC) Made in RC-17-0169 RC-18-0070, (Vcsns), Unit 1 - Relief Request RR-4-14, Use of a Performance Based Testing Frequency for Pressure Isolation Valves as an Alternative to the Requirements of the American Society of Mechanical Engineers Code for ...2018-10-0808 October 2018 (Vcsns), Unit 1 - Relief Request RR-4-14, Use of a Performance Based Testing Frequency for Pressure Isolation Valves as an Alternative to the Requirements of the American Society of Mechanical Engineers Code for ... RC-18-0067, (Vcsns), Unit 1 - License Amendment Request - LAR-16-00644 - Revise Reactor Coolant System Operational Leakage Technical Specification Surveillance Requirement 4.4.6.2.22018-10-0808 October 2018 (Vcsns), Unit 1 - License Amendment Request - LAR-16-00644 - Revise Reactor Coolant System Operational Leakage Technical Specification Surveillance Requirement 4.4.6.2.2 RC-18-0123, NRC Request for Information Baseline Radiation Safety Inspection2018-10-0404 October 2018 NRC Request for Information Baseline Radiation Safety Inspection RC-18-0117, (Vcsns), Unit 1 - Fukushima Near-Term Task Force Recommendation 3.1: Seismic Probabilistic Risk Assessment2018-09-28028 September 2018 (Vcsns), Unit 1 - Fukushima Near-Term Task Force Recommendation 3.1: Seismic Probabilistic Risk Assessment RC-18-0112, (Vcsns), Unit 1 - Request for License Amendment to Virgil C. Summer Nuclear Station Technical Specification 3.8.2, D.C. Sources - Operating, Surveillance Requirements 4.8.2.1.B.2 and 4.8.2.1.C.32018-09-27027 September 2018 (Vcsns), Unit 1 - Request for License Amendment to Virgil C. Summer Nuclear Station Technical Specification 3.8.2, D.C. Sources - Operating, Surveillance Requirements 4.8.2.1.B.2 and 4.8.2.1.C.3 RC-18-0119, (Vcsns), Unit 1 - Supplement to License Amendment Request LAR-18-03422, Request for a One-Time Extension to the Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation2018-09-19019 September 2018 (Vcsns), Unit 1 - Supplement to License Amendment Request LAR-18-03422, Request for a One-Time Extension to the Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation RC-18-0118, (Vcsns), Unit 1 - Relief Request RR-4-18, Request for a Temporary Non-Code Repair of a Service Water System Flange2018-09-14014 September 2018 (Vcsns), Unit 1 - Relief Request RR-4-18, Request for a Temporary Non-Code Repair of a Service Water System Flange RC-18-0116, (Vcsns), Unit 1 - Request for a One-Time Extension to the Surveillance Frequency 4.4.4.6 of the Core Exit Temperature Instrumentation - Response to Request for Additional Information2018-09-11011 September 2018 (Vcsns), Unit 1 - Request for a One-Time Extension to the Surveillance Frequency 4.4.4.6 of the Core Exit Temperature Instrumentation - Response to Request for Additional Information RC-18-0113, (Vcsns), Unit 1 - Supplement to License Amendment Request LAR-18-03422 Request for a One-Time Extension to the Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation2018-08-31031 August 2018 (Vcsns), Unit 1 - Supplement to License Amendment Request LAR-18-03422 Request for a One-Time Extension to the Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation RC-18-0091, License Amendment Request - LAR-16-01490 National Fire Protection Association Standard 805 Program Revisions2018-08-29029 August 2018 License Amendment Request - LAR-16-01490 National Fire Protection Association Standard 805 Program Revisions RC-18-0111, License Amendment Request LAR-18-03422 Request for a One-Time Extension to the Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation2018-08-24024 August 2018 License Amendment Request LAR-18-03422 Request for a One-Time Extension to the Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation RC-18-0100, (Vcsns), Unit 1 - Technical Specification Change Request for the Revision of the Surveillance Frequency of the Turbine Trip Functional Unit: Response to Request for Additional Information2018-08-22022 August 2018 (Vcsns), Unit 1 - Technical Specification Change Request for the Revision of the Surveillance Frequency of the Turbine Trip Functional Unit: Response to Request for Additional Information RC-18-0105, (Vcsns), Unit 1 - Relief Request RR-4-17, Request to Utilize Code Case N-513-3 'Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Division 1' for a Service Water ..2018-08-14014 August 2018 (Vcsns), Unit 1 - Relief Request RR-4-17, Request to Utilize Code Case N-513-3 'Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Division 1' for a Service Water .. RC-18-0102, Withdrawal of Request to Revise Technical Specifications to Correct an Administrative Error2018-08-10010 August 2018 Withdrawal of Request to Revise Technical Specifications to Correct an Administrative Error RC-18-0098, (Vcsns), Units 1, 2 and 3 - Modification of Requested Latest Completion Date in Application for Order Approving Indirect Transfer of Control of Operating License and Combined Licenses2018-07-30030 July 2018 (Vcsns), Units 1, 2 and 3 - Modification of Requested Latest Completion Date in Application for Order Approving Indirect Transfer of Control of Operating License and Combined Licenses RC-18-0085, (Vcsns), Unit 1 - Notification of an Intended Change to a Commitment Made in RC-17-01262018-07-23023 July 2018 (Vcsns), Unit 1 - Notification of an Intended Change to a Commitment Made in RC-17-0126 RC-18-0090, (Vcsns), Unit 1 - Relief Request RR-4-16, Request for Alternative to Implement Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Response to Request...2018-07-12012 July 2018 (Vcsns), Unit 1 - Relief Request RR-4-16, Request for Alternative to Implement Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Response to Request... RC-18-0089, (Vcsns), Unit 1 - Relief Request RR-4-16, Request for Alternative to Implement Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping2018-07-11011 July 2018 (Vcsns), Unit 1 - Relief Request RR-4-16, Request for Alternative to Implement Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping RC-18-0084, Virgil C Summer Nuclear Station (Vcsns), Unit 1 - Relief Request RR-4-15, Request for Alternative to Implement Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Laws in Moderate Energy Class 2 or 3 Piping Response to Requ2018-07-0303 July 2018 Virgil C Summer Nuclear Station (Vcsns), Unit 1 - Relief Request RR-4-15, Request for Alternative to Implement Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Laws in Moderate Energy Class 2 or 3 Piping Response to Reques RC-18-0082, Relief Request RR-4-15, Request for Alternative to Implement Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping2018-07-0303 July 2018 Relief Request RR-4-15, Request for Alternative to Implement Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping RC-18-0079, Vigil C. Summer Nuclear Station (Vcsns), Unit 1 - Request to Revise Technical Specifications to Correct an Administrative Error2018-06-29029 June 2018 Vigil C. Summer Nuclear Station (Vcsns), Unit 1 - Request to Revise Technical Specifications to Correct an Administrative Error RC-18-0074, Change of the Commitment Date of DRIB/105A&B Door Submittal2018-06-18018 June 2018 Change of the Commitment Date of DRIB/105A&B Door Submittal RC-18-0060, (VCSNS) - Request to Revise Technical Specifications to Correct Administrative Error2018-05-30030 May 2018 (VCSNS) - Request to Revise Technical Specifications to Correct Administrative Error RC-18-0064, (Vcsns), Unit 1 - Annual Commitment Change Summary Report2018-05-18018 May 2018 (Vcsns), Unit 1 - Annual Commitment Change Summary Report RC-18-0063, Submittal of 10 CFR 72.48 Biennial Report for the Independent Spent Fuel Storage Installation2018-05-0202 May 2018 Submittal of 10 CFR 72.48 Biennial Report for the Independent Spent Fuel Storage Installation RC-18-0056, (Vcsns), Unit 1 - Licensee Event Reports (2016-001-02, 2016-002-01, 2016-003-02) - Revision to Correct Typographical Errors2018-04-25025 April 2018 (Vcsns), Unit 1 - Licensee Event Reports (2016-001-02, 2016-002-01, 2016-003-02) - Revision to Correct Typographical Errors RC-18-0059, Annual Radioactive Effluent Release Report2018-04-25025 April 2018 Annual Radioactive Effluent Release Report RC-18-0046, License Amendment Request LAR-14-01541 Integrated Leak Rate Test Peak Calculated Containment Internal Pressure Change Request for Additional Information2018-04-19019 April 2018 License Amendment Request LAR-14-01541 Integrated Leak Rate Test Peak Calculated Containment Internal Pressure Change Request for Additional Information RC-18-0036, (Vcsns), Unit 1 - Relief Request RR-4-13, Use of a Risk-Informed Process as an Alternative for the Selection of Class 1 and Class 2 Piping Welds - Response to Request for Additional Information2018-04-0202 April 2018 (Vcsns), Unit 1 - Relief Request RR-4-13, Use of a Risk-Informed Process as an Alternative for the Selection of Class 1 and Class 2 Piping Welds - Response to Request for Additional Information RC-18-0041, Report of Status of Decommissioning Funding2018-03-28028 March 2018 Report of Status of Decommissioning Funding RC-17-0175, Correction to Amendment No. 170 Request to Revise Technical Specifications to Correct Administrative Error2018-01-31031 January 2018 Correction to Amendment No. 170 Request to Revise Technical Specifications to Correct Administrative Error RC-18-0006, Independent Spent Fuel Storage Installation Re Application for Order Approving Indirect Transfer of Control of Operating License and Combined Licenses2018-01-25025 January 2018 Independent Spent Fuel Storage Installation Re Application for Order Approving Indirect Transfer of Control of Operating License and Combined Licenses RC-17-0169, Notification of an Intended Change of a Commitment Date for Open Phase Condition Made in RC-14-00192017-12-11011 December 2017 Notification of an Intended Change of a Commitment Date for Open Phase Condition Made in RC-14-0019 RC-17-0182, (VCSNS) - Anchor Darling Double Disc Gate Valve Information and Status2017-12-11011 December 2017 (VCSNS) - Anchor Darling Double Disc Gate Valve Information and Status RC-17-0172, Notification of Personnel Changes2017-11-30030 November 2017 Notification of Personnel Changes RC-17-0161, Submittal of Change of the Commitment Date of DRIB/105A&B Door2017-11-28028 November 2017 Submittal of Change of the Commitment Date of DRIB/105A&B Door RC-17-0135, Annual Commitment Change Summary Report2017-11-0303 November 2017 Annual Commitment Change Summary Report RC-17-0123, Relief Request RR-4-13, Use of a Risk-Informed Process as an Alternative for the Selection of Class 1 and Class 2 Piping Welds2017-10-30030 October 2017 Relief Request RR-4-13, Use of a Risk-Informed Process as an Alternative for the Selection of Class 1 and Class 2 Piping Welds RC-17-0140, Transmittal of 10 CFR 50.59 Biennial Report2017-10-23023 October 2017 Transmittal of 10 CFR 50.59 Biennial Report RC-17-0107, (Vcsns), Unit 1 - Integrated Leak Rate Test Peak Calculated Containment Internal Pressure Change2017-10-0606 October 2017 (Vcsns), Unit 1 - Integrated Leak Rate Test Peak Calculated Containment Internal Pressure Change RC-17-0134, Response to Request for Supplemental Information, License Amendment Request - LAR-15-01424; Implementation of WCAP-15376-P-A, Revision 12017-09-27027 September 2017 Response to Request for Supplemental Information, License Amendment Request - LAR-15-01424; Implementation of WCAP-15376-P-A, Revision 1 RC-17-0126, Reply to a Notice of Violation, Per Inspection Report 05000395/20170022017-09-0606 September 2017 Reply to a Notice of Violation, Per Inspection Report 05000395/2017002 RC-17-0112, Special Report (Spr) 2017-007 Regarding Waste Gas Holdup System Explosive Gas Monitoring System Being Inoperable for Greater than Thirty Days2017-09-0101 September 2017 Special Report (Spr) 2017-007 Regarding Waste Gas Holdup System Explosive Gas Monitoring System Being Inoperable for Greater than Thirty Days RC-17-0069, (Vcsns), Unit 1 - Quality Assurance Approval Certificate No. 0479, Transmittal of the Quality Assurance Program Description2017-08-30030 August 2017 (Vcsns), Unit 1 - Quality Assurance Approval Certificate No. 0479, Transmittal of the Quality Assurance Program Description 2022-01-14
[Table view] Category:Status Report
MONTHYEARML23089A3892023-03-30030 March 2023 (Vcsns), Unit 1 - Decommissioning Funding Status Report ML21099A1072021-03-30030 March 2021 Report of Status of Decommissioning Funding ML21085A6252021-03-25025 March 2021 (VCSNS) Unit 1 - Decommissioning Funding Status Report RC-19-0012, NPDES Permit No. SC0030856 Renewal Application, Operational Status2019-01-31031 January 2019 NPDES Permit No. SC0030856 Renewal Application, Operational Status ML18213A1552018-07-23023 July 2018 Status Report on South Carolina Public Service Authority'S Position on the Termination of the COL for VCSNS Units 2 & 3 ML18206A2302018-07-23023 July 2018 Santee Cooper Letter to NRC Regarding the V.C. Summer, Units 2 & 3, Position on the Termination of the COL for VCSNS ND-18-0002, Submittal of Six (6) Month Status Report Regarding Implementation of the Overall Integrated Plan for Mitigation Strategies for Beyond Design Basis External Events2018-02-15015 February 2018 Submittal of Six (6) Month Status Report Regarding Implementation of the Overall Integrated Plan for Mitigation Strategies for Beyond Design Basis External Events ML17090A1122017-03-30030 March 2017 Report of Status of Decommissioning Funding RC-17-0037, Report of Status of Decommissioning Funding2017-03-28028 March 2017 Report of Status of Decommissioning Funding ML16243A4642016-08-29029 August 2016 Seventh Six-Month Status Report in Response to 03/12/2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-049) RC-15-0125, Fifth Six-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049)2015-08-24024 August 2015 Fifth Six-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049) RC-15-0126, Fifth 6-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051)2015-08-20020 August 2015 Fifth 6-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051) RC-15-0055, V.C. Summer, Report of Status of Decommissioning Funding2015-03-30030 March 2015 V.C. Summer, Report of Status of Decommissioning Funding ML15090A1972015-03-27027 March 2015 Report of Status of Decommissioning Funding RC-15-0031, Fourth 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation2015-02-27027 February 2015 Fourth 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation RC-14-0141, Third 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation2014-08-28028 August 2014 Third 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation RC-14-0144, Third Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-04)2014-08-28028 August 2014 Third Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-04) RC-14-0031, Second 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation2014-02-27027 February 2014 Second 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation RC-14-0030, South Carolina Electric & Gas Company'S Second Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External..2014-02-27027 February 2014 South Carolina Electric & Gas Company'S Second Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External.. RC-13-0117, 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation2013-08-28028 August 2013 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation RC-13-0123, V. C. Summer, Unit 1 - First Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order No. EA-12-049)2013-08-28028 August 2013 V. C. Summer, Unit 1 - First Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order No. EA-12-049) ML13091A0742013-03-28028 March 2013 Report of Status of Decommissioning Funding RC-13-0051, Report of Status of Decommissioning Funding2013-03-27027 March 2013 Report of Status of Decommissioning Funding ML1214500142012-05-23023 May 2012 NFPA 805 LAR Status Matrix - May 2012 RC-09-0032, Report of Status of Decommissioning Funding2009-03-30030 March 2009 Report of Status of Decommissioning Funding ML0909103522009-03-30030 March 2009 Report of Status of Decommissioning Funding ML0309805402003-03-31031 March 2003 Report of Status of Decommissioning Funding ML0224007812002-01-18018 January 2002 E-mail from Jacob Zimmerman, Bulletin 2001-01 Status Report 2023-03-30
[Table view] |
Text
4 Thomas D. Gatlin Vice President, Nuclear Operations (803) 345-4342 S GAugust CE & 20, 2015 RC-1 5-0126 A SCANA COMPANY U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001
Dear Sir!/ Madam:
Subject:
VIRGIL C. SUMMER NUCLEAR STATION (VCSNS), UNIT 1 DOCKET NO. 50-395 OPERATING LICENSE NO. NPF-12 FIFTH 6-MONTH STATUS REPORT IN RESPONSE TO MARCH 12, 2012, COMMISSION ORDER MODIFYING LICENSES WITH REGARD TO RELIABLE SPENT FUEL POOL INSTRUMENTATION (ORDER EA-12-051)
References:
- 1. Nuclear Regulatory Commission Order Number EA-12-051, Issuance of Order to Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation, dated March 12, 2012, Agencywide Documents Access and Management System (ADAMS) Accession Number ML12054A679
- 2. SCE&G Letter, Virgil C. Summer Nuclear Station (VCSNS) Unit 1- Integrated Plan with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051), dated February 28, 2013, ADAMS Accession No. ML13063A099 On March 12, 2012, the Nuclear Regulatory Commission issued Order EA-12-051 (i.e.,
Reference 1) to South Carolina Electric & Gas Company (SCE&G). Reference 1 was immediately effective and directs SCE&G to have a reliable indication of the water level in associated spent fuel storage pools. Specific requirements are outlined in Attachment 2 of Reference 1.
In response to Reference 1, SCE&G developed an Overall Integrated Plan (i.e., Reference 2) for Virgil C. Summer Nuclear Station, Unit 1, documenting the requirements to install reliable spent fuel pool level instrumentation. Reference 1 requires submission of status reports at 6-month intervals following submittal of the Overall Integrated Plan. The purpose of this letter is to provide the fifth 6-month status report pursuant to Section IV, Condition C.2, of Reference 1, that delineates the progress made in implementing the requirements. The attached report provides an update on milestone accomplishments since the last status report and identifies changes to the compliance method, schedule, or need for relief/relaxation, if any.
This letter contains no new regulatory commitments. If you have any questions regarding this report, please contact Bruce L. Thompson at (803) 931-5042.
Box 88. Jenkinsville, Sc. 29065.* F(803) 941-9776 V.C.Summer Nuclear Station.* P.O0. / - O
Document Control Desk CR-12-01 070 RC-1 5-0126 Page 2 of 2 I certify under penalty of perjury that the foregoing is true and correct.
E*, te on Thomas D. Gatlin PF/TDG/ts
Enclosure:
Virgil C. Summer Nuclear Station (VCSNS) Unit 1- Fifth 6-Month Status Report in Response to NRC Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051 )
c: K. B. Marsh S. A. Byrne J. B. Archie N. S. Camns J. H. Hamilton J. W. Williams W. M. Cherry W. M. Dean V. M. McCree (w/attachment)
S. A. Williams (w/attachment)
M. A. Brown (w/attachment)
NRC Resident Inspector K. M. Sutton NSRC RTS (CR-12-01070)
File (815.07)
PRSF (RC-15-0126)
Document Control Desk CR-i12-01070 RC-l15-0126 Enclosure Page 1 of 5 VIRGIL C. SUMMER NUCLEAR STATION (VCSNS) UNIT 1 ENCLOSURE FIFTH 6-MONTH STATUS REPORT IN RESPONSE TO NRC ORDER MODIFYING LICENSES WITH REGARD TO RELIABLE SPENT FUEL POOL INSTRUMENTATION (ORDER EA-12-051)
- 1. Introduction SCE&G developed an Overall Integrated Plan (i.e., Reference 2 in Section 8) for Virgil C.
Summer Nuclear Station (VCSNS), Unit 1, documenting the requirements to install reliable spent fuel pool level instrumentation (SFPLI), in response to NRC Order EA-12-051 (i.e.,
Reference 1 in Section 8). Subsequently, SCE&G provided the first, second, third, and fourth 6-month status reports (i.e., References 4, 5, 8, and 10 in Section 8, respectively) to the NRC.
This report provides an update of milestone accomplishments since submittal of the last status report, including any changes to the compliance method, schedule, or need for relief/relaxation and the basis, if any, that occurred during the period from February 19, 2015, to August 10, 2015 (hereafter referred to as the update period).
- 2. Milestone Accomplishments The following milestone(s) in Section 3 have been completed during this update period.
- 3. Milestone Schedule Status The following provides an update to the milestone schedule to support the Overall integrated Plan. This section provides the activity status of each item and the expected completion date.
The target completion dates are planning dates subject to change as design and implementation details are developed.
The revised milestone target completion dates do not impact the order implementation date.
Document Control Desk CR-12-01 070 RC-1 5-01 26 Enclosure Page 2 of 5 Target Revised Milestone Completion Activity Target DaeStatus Completion Date Date Submit 60 Day Status Report Oct 2012 Complete Submit Overall Integrated Plan Feb 2013 Complete Submit Response to RAls on OverallAu203Cmlt Integrated PlanAu213Cmet Submit Response to RAls on OverallOc204Cmlt Integrated PlanOc204Cmlt Submit 6 Month Updates:
Update 1 Aug 2013 Complete Update 2 Feb 2014 Complete Update 3 Aug 2014 Complete Update 4 Feb 2015 Complete Update 5 Aug 2015 Complete Update 6 Feb 2016 Not Started Modifications:
Modification Development Jan 2014 Complete January 2015 Complete Procurement ofJu203Cmlt Instrumentation Package Complete Engineering and Design Jul 2014 Complete January 2015 Commence Implementation Oct 2014 Complete April 2015 Unit 1 Implementation Outage Oct 2015 Not Started Procedures:
Complete Procedures Development Feb 2015 In Progress October 2015
_________ I
___ I___ I___
Document Control Desk CR-I12-01070 RC-1 5-0126 Enclosure Page 3 of 5 Target Revised Miesoe omltin Activity Target DattoeCopeto Status Completion Date Date Training:
Develop Training Plan Feb 2015 Complete June 2015 Training Complete Aug 2015 In Progress
- 4. Changes to Compliance Method VCSNS has elected to use an alternate compliance method regarding the design of the backup SFPLI channel. Part of the backup channel is located on the exterior of the Spent Fuel Pool, just outside the Auxiliary Building. The backup channel waveguide pipe exits the Fuel Handling Building at the west wall and is routed to a transmitter located outside. The remote transmitter, display, panels, and associated conduit for the backup channel are mounted on the outside of the Fuel Handing Building. These components are protected from all hazards except for the high winds hazard. This design differs from the guidelines in Section 3, Instrumentation Design Features, of Nuclear Energy Institute (NEI) 12-02.
Justification for use of an alternate method includes the following:
- The primary SFPLI channel display is located in the Auxiliary Building, a structure which is protected from all applicable external hazards. The primary channel display can be accessed from the Control Room via a path through safety related structures.
- NEI guidance specifies that the primary or backup SFPLI channel can be out of service for up to 90 days provided the other channel is functional. The allowable outage time for VCSNS's primary SFPLI channel will be reduced from 90 days to 45 days.
- The backup SFPLI channel is seismically qualified and located on a seismically qualified wall of the Fuel Handling Building. The panel and display locations are elevated above the maximum water level of 18 inches, so the channel is protected from the flooding hazard.
- Although the backup SFPLI channel is not protected from tornados, and may undergo damage as a result of high winds and/or missiles, the number of potential missiles is minimized by VCSNS's Station Housekeeping Program, SAP-I142, and the Natural Emergency Procedure, EPP-015.
- VCSNS has two narrow range SFPLI channels with indication in the Control Room.
These channels should remain available following a tornado. The level in the Spent Fuel Pool is kept within the range of these narrow range instruments through use of the FLEX procedure for providing SFP makeup, Alternate SFP Makeup and Cooling, FSP 11.0.
- The backup SFPLI channel display is located near the staging area of FLEX pumps which will be used to deliver makeup to the Spent Fuel Pool.
Document Control Desk CR-1 2-01070 RC- 15-0126 Enclosure Page 4 of 5
- 5. Need for Relief/Relaxation and Basis for the Relief/Relaxation SCE&G expects to comply with the order implementation date and no relief/relaxation is required at this time.
- 6. Open Items from Overall Integrated Plan and Draft Safety Evaluation There are no open items documented in the CIP or in the Interim Staff Evaluation (ISE). The ISE (Reference 7 in Section 8) included a Request for Additional Information (RAl). Reference 11 in Section 8 instructs that responses to the RAI do not need to be formally submitted on the docket but instead to place the response in the e-Portal. An updated response to the PAl has been placed on the VCSNS e-Portal. This response reflects the information provided to the NRC during the on-site audit which was conducted the week of July 1 3 th, 2015.
One RAI remained open following the NRC Audit. This item is listed below.
SFPI PAl-1 Please provide additional information describing how the design of shielding for the SEP level instrumentation meets the requirement of the Order to arrange the instruments in a manner that provides reasonable protection of the level indication function against missiles that may result from damage to the structure over the SFP. Also, describe plans for protecting any equipment mounted outside the buildings from the effects of tornado-driven missiles, freezing, elevated temperature, humidity, flooding, and other Beyond Design Basis conditions.
- 7. Potential Draft Safety Evaluation Impacts No potential impacts to the Draft Safety Evaluation have been identified.
- 8. References The following references support the information contained within this enclosure.
- 1. NRC Order Number EA-1 2-051, Issuance of Orderto Modify Licenses with Regard to Reliable Spent Fuel Pool Instrumentation, dated March 12, 2012, ADAMS Accession No. ML12054A679
- 2. SCE&G Letter, Virgil C. Summer Nuclear Station (VCSNS) Unit 1- Integrated Plan with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation (OrderNumber EA-12-051), dated February 28, 2013, ADAMS Accession No. ML13063A099
- 3. NRC Letter, Virgil C. Summer Nuclear Station, Unit 1- Request for Additional Information Regarding Overall Integrated Plan for Reliable Spent Fuel Pool Instrumentation (Order Number EA-1 2-051) (TAC NO. MF1173), dated July 29, 2013, ADAMS Accession No. ML13203A180
- 4. SCE&G Letter, Virgil C. Summer Nuclear Station (VCSNS) Unit 1- 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable
Document Control Desk CR-12-01 070 RC-1 5-0126 Enclosure Page 5 of 5 Spent Fuel Pool Instrumentation, dated August 28, 2013, ADAMS Accession No. ML13242A272
- 5. SCE&G Letter, Virgil C. Summer Nuclear Station (VCSNS) Unit 1- Second 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation, dated February 27, 2014, ADAMS Accession No. ML14063A201
- 6. SCE&G Letter, Virgil C. Summer Nuclear Station (VCSNS) Unit 1- Response to Request for Additional Information - Overall Integrated Plan in Response to Commission Order Modifying License Requirements for Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051), dated August 28, 2013, ADAMS Accession No. ML13247A338
- 7. NRC Letter, Virgil C. Summer Nuclear Station, Unit 1- Interim Staff Evaluation and Request for Additional Information Regarding the Overall Integrated Plan for Implementation of Order EA-12-051, Reliable Spent Fuel Pool Instrumentation (TAC NO.
MF1173), dated December 5, 2013, ADAMS Accession No. ML13305A100
- 8. SCE&G Letter, Virgil C. Summer Nuclear Station (VCSNS) Unit 1- Third 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation, dated August 28, 2014, ADAMS Accession No. ML14245A404
- 9. SCE&G Letter, Virgil C. Summer Nuclear Station (VCSNS) Unit 1- Response to Request for Additional Information - Overall IntegratedPlan in Response to Commission Order Modifying License Requirements for Reliable Spent Fuel Pool Instrumentation (Order No.
EA-12-05 1), dated October 29, 2014, ADAMS Accession No. ML14304A538
- 10. SCE&G Letter, Virgil C. Summer Nuclear Station (VCSNS) Unit 1- Fourth 6-Month Status Report of Order EA-12-051, OrderModifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation, dated February 27, 2015, ADAMS Accession No. ML15062A008
- 11. NRC Letter, Nuclear Regulatory Commission Audits of Licensee Responses to Reliable Spent Fuel Pool Instrumentation Order EA-12-051, Dated March 26, 2014, ADAMS Accession No. ML14083A620