Letter Sequence Other |
---|
|
Results
Other: ML15147A056, ML15253A721, RC-13-0031, Integrated Plan with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051), RC-13-0117, 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation, RC-15-0031, Fourth 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation, RC-15-0125, Fifth Six-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049), RC-15-0126, Fifth 6-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051)
|
MONTHYEARRC-13-0031, Integrated Plan with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051)2013-02-28028 February 2013 Integrated Plan with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051) Project stage: Other RC-13-0109, Online Reference Portal for Review of Mitigation Strategies, Submittal in Response to Order EA-12-0492013-07-26026 July 2013 Online Reference Portal for Review of Mitigation Strategies, Submittal in Response to Order EA-12-049 Project stage: Other ML13203A1802013-07-29029 July 2013 Request for Additional Information Regarding Overall Integrated Plan for Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051) Project stage: RAI RC-13-0119, Transmittal of Figures Associated with South Carolina Electric & Gas Company Response to the NRC Request for Additional Information Regarding the VCSNS Overall Integrated Plan (RC-13-0119)2013-08-13013 August 2013 Transmittal of Figures Associated with South Carolina Electric & Gas Company Response to the NRC Request for Additional Information Regarding the VCSNS Overall Integrated Plan (RC-13-0119) Project stage: Request ML13247A3382013-08-28028 August 2013 Response to Request for Additional Information - Overall Integrated Plan to Commission Order Modifying License Requirements for Reliable Spent Fuel Pool Instrumentation (Order No. EA-12-051) Project stage: Response to RAI RC-13-0123, V. C. Summer, Unit 1 - First Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order No. EA-12-049)2013-08-28028 August 2013 V. C. Summer, Unit 1 - First Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order No. EA-12-049) Project stage: Other RC-13-0117, 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation2013-08-28028 August 2013 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation Project stage: Other ML13305A1002013-12-0505 December 2013 Interim Staff Evaluation and Request for Additional Information Regarding the Overall Integrated Plan for Implementation of Order EA-12-051, Reliable Spent Fuel Pool Instrumentation Project stage: RAI ML14034A3392014-02-21021 February 2014 Interim Staff Evaluation Relating to Overall Integrated Plan in Response to Order EA-12-049 (Mitigation Strategies) Project stage: Acceptance Review ML14037A2282014-02-21021 February 2014 Mega-Tech Services, LLC Technical Evaluation Report Regarding the Overall Integrated Plan for Virgil C. Summer Nuclear Station, Unit 1, TAC MF2338 Project stage: Other ML14056A0672014-02-21021 February 2014 Fifth Batch SE Final Revision 3- 1 Site (VC Summer) Project stage: Other RC-14-0030, South Carolina Electric & Gas Company'S Second Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External..2014-02-27027 February 2014 South Carolina Electric & Gas Company'S Second Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External.. Project stage: Other RC-14-0144, Third Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-04)2014-08-28028 August 2014 Third Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-04) Project stage: Other RC-15-0031, Fourth 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation2015-02-27027 February 2015 Fourth 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation Project stage: Other RC-15-0030, Fourth Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events.2015-02-27027 February 2015 Fourth Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events. Project stage: Other ML15147A0562015-06-0202 June 2015 Plan for the Onsite Audit Regarding Implementation of Mitigating Strategies and Reliable Spent Fuel Instrumentation Related to Orders EA-12-049 and EA-12-051 Project stage: Other RC-15-0117, Request for Schedule Relaxation from NRC Order EA-12-049, Issuance of Order to Modify Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events.2015-08-13013 August 2015 Request for Schedule Relaxation from NRC Order EA-12-049, Issuance of Order to Modify Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events. Project stage: Request RC-15-0126, Fifth 6-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051)2015-08-20020 August 2015 Fifth 6-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051) Project stage: Other RC-15-0125, Fifth Six-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049)2015-08-24024 August 2015 Fifth Six-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049) Project stage: Other ML15253A7212015-09-16016 September 2015 Report for the Onsite Audit Regarding Implementation of Mitigating Strategies and Reliable Spent Fuel Instrumentation Related to Orders EA-12-049 and EA-12-051 Project stage: Other ML15243A4502015-10-0404 October 2015 Relaxation of the Schedule Requirements of Order EA-12 049 Issuance of Order T Modify Licenses with Regard to Requirements for Mitigation Strategies for Beyond Design Basis External Events Project stage: Approval RC-16-0001, V.C. Summer, Report of Full Compliance with March 12, 2012, Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051) and Responses to Requests for Additional Information2016-01-22022 January 2016 V.C. Summer, Report of Full Compliance with March 12, 2012, Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051) and Responses to Requests for Additional Information Project stage: Response to RAI RC-16-0028, Notification of an Intended Changed to a Commitment Date for Response to Request for Additional Information Regarding Phase 2 Staffing Submittals Associated with Near-Term Task Force Recommendation 9.3 Related to the Fukushima..2016-02-26026 February 2016 Notification of an Intended Changed to a Commitment Date for Response to Request for Additional Information Regarding Phase 2 Staffing Submittals Associated with Near-Term Task Force Recommendation 9.3 Related to the Fukushima.. Project stage: Response to RAI 2014-08-28
[Table View] |
|
---|
Category:Letter type:RC
MONTHYEARRC-22-0004, (Vcsns), Unit 1 - 2021 Annual Letter of Certification and Testing Results of the Public Alerting System2022-01-14014 January 2022 (Vcsns), Unit 1 - 2021 Annual Letter of Certification and Testing Results of the Public Alerting System RC-18-0157, (Vcsns), Units 1, 2 and 3 Independent Spent Fuel Storage Installation - Order Approving Indirect Transfer of Control of Operating License and Combined Licenses2018-12-28028 December 2018 (Vcsns), Units 1, 2 and 3 Independent Spent Fuel Storage Installation - Order Approving Indirect Transfer of Control of Operating License and Combined Licenses RC-18-0149, ISFSI - Order Approving Indirect Transfer of Control of Operating License and Combined Licenses2018-12-21021 December 2018 ISFSI - Order Approving Indirect Transfer of Control of Operating License and Combined Licenses RC-18-0136, (Vcsns), Unit 1 - Request to Remove the Expired One-Time Extension to Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation and to Remove the Index from Technical Specifications (LAR-18-04683)2018-12-12012 December 2018 (Vcsns), Unit 1 - Request to Remove the Expired One-Time Extension to Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation and to Remove the Index from Technical Specifications (LAR-18-04683) RC-18-0144, (Vcsns), Unit 1 - Core Operating Limits Report (COLR) for Cycle 252018-11-20020 November 2018 (Vcsns), Unit 1 - Core Operating Limits Report (COLR) for Cycle 25 RC-18-0126, (Vcsns), Unit 1 - Notification of an Intended Change a Commitment Date for Open Phase Condition (OPC) Made in RC-17-01692018-11-0909 November 2018 (Vcsns), Unit 1 - Notification of an Intended Change a Commitment Date for Open Phase Condition (OPC) Made in RC-17-0169 RC-18-0070, (Vcsns), Unit 1 - Relief Request RR-4-14, Use of a Performance Based Testing Frequency for Pressure Isolation Valves as an Alternative to the Requirements of the American Society of Mechanical Engineers Code for ...2018-10-0808 October 2018 (Vcsns), Unit 1 - Relief Request RR-4-14, Use of a Performance Based Testing Frequency for Pressure Isolation Valves as an Alternative to the Requirements of the American Society of Mechanical Engineers Code for ... RC-18-0067, (Vcsns), Unit 1 - License Amendment Request - LAR-16-00644 - Revise Reactor Coolant System Operational Leakage Technical Specification Surveillance Requirement 4.4.6.2.22018-10-0808 October 2018 (Vcsns), Unit 1 - License Amendment Request - LAR-16-00644 - Revise Reactor Coolant System Operational Leakage Technical Specification Surveillance Requirement 4.4.6.2.2 RC-18-0123, NRC Request for Information Baseline Radiation Safety Inspection2018-10-0404 October 2018 NRC Request for Information Baseline Radiation Safety Inspection RC-18-0117, (Vcsns), Unit 1 - Fukushima Near-Term Task Force Recommendation 3.1: Seismic Probabilistic Risk Assessment2018-09-28028 September 2018 (Vcsns), Unit 1 - Fukushima Near-Term Task Force Recommendation 3.1: Seismic Probabilistic Risk Assessment RC-18-0112, (Vcsns), Unit 1 - Request for License Amendment to Virgil C. Summer Nuclear Station Technical Specification 3.8.2, D.C. Sources - Operating, Surveillance Requirements 4.8.2.1.B.2 and 4.8.2.1.C.32018-09-27027 September 2018 (Vcsns), Unit 1 - Request for License Amendment to Virgil C. Summer Nuclear Station Technical Specification 3.8.2, D.C. Sources - Operating, Surveillance Requirements 4.8.2.1.B.2 and 4.8.2.1.C.3 RC-18-0119, (Vcsns), Unit 1 - Supplement to License Amendment Request LAR-18-03422, Request for a One-Time Extension to the Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation2018-09-19019 September 2018 (Vcsns), Unit 1 - Supplement to License Amendment Request LAR-18-03422, Request for a One-Time Extension to the Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation RC-18-0118, (Vcsns), Unit 1 - Relief Request RR-4-18, Request for a Temporary Non-Code Repair of a Service Water System Flange2018-09-14014 September 2018 (Vcsns), Unit 1 - Relief Request RR-4-18, Request for a Temporary Non-Code Repair of a Service Water System Flange RC-18-0116, (Vcsns), Unit 1 - Request for a One-Time Extension to the Surveillance Frequency 4.4.4.6 of the Core Exit Temperature Instrumentation - Response to Request for Additional Information2018-09-11011 September 2018 (Vcsns), Unit 1 - Request for a One-Time Extension to the Surveillance Frequency 4.4.4.6 of the Core Exit Temperature Instrumentation - Response to Request for Additional Information RC-18-0113, (Vcsns), Unit 1 - Supplement to License Amendment Request LAR-18-03422 Request for a One-Time Extension to the Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation2018-08-31031 August 2018 (Vcsns), Unit 1 - Supplement to License Amendment Request LAR-18-03422 Request for a One-Time Extension to the Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation RC-18-0091, License Amendment Request - LAR-16-01490 National Fire Protection Association Standard 805 Program Revisions2018-08-29029 August 2018 License Amendment Request - LAR-16-01490 National Fire Protection Association Standard 805 Program Revisions RC-18-0111, License Amendment Request LAR-18-03422 Request for a One-Time Extension to the Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation2018-08-24024 August 2018 License Amendment Request LAR-18-03422 Request for a One-Time Extension to the Surveillance Frequency 4.3.3.6 of the Core Exit Temperature Instrumentation RC-18-0100, (Vcsns), Unit 1 - Technical Specification Change Request for the Revision of the Surveillance Frequency of the Turbine Trip Functional Unit: Response to Request for Additional Information2018-08-22022 August 2018 (Vcsns), Unit 1 - Technical Specification Change Request for the Revision of the Surveillance Frequency of the Turbine Trip Functional Unit: Response to Request for Additional Information RC-18-0105, (Vcsns), Unit 1 - Relief Request RR-4-17, Request to Utilize Code Case N-513-3 'Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Division 1' for a Service Water ..2018-08-14014 August 2018 (Vcsns), Unit 1 - Relief Request RR-4-17, Request to Utilize Code Case N-513-3 'Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Section XI, Division 1' for a Service Water .. RC-18-0102, Withdrawal of Request to Revise Technical Specifications to Correct an Administrative Error2018-08-10010 August 2018 Withdrawal of Request to Revise Technical Specifications to Correct an Administrative Error RC-18-0098, (Vcsns), Units 1, 2 and 3 - Modification of Requested Latest Completion Date in Application for Order Approving Indirect Transfer of Control of Operating License and Combined Licenses2018-07-30030 July 2018 (Vcsns), Units 1, 2 and 3 - Modification of Requested Latest Completion Date in Application for Order Approving Indirect Transfer of Control of Operating License and Combined Licenses RC-18-0085, (Vcsns), Unit 1 - Notification of an Intended Change to a Commitment Made in RC-17-01262018-07-23023 July 2018 (Vcsns), Unit 1 - Notification of an Intended Change to a Commitment Made in RC-17-0126 RC-18-0090, (Vcsns), Unit 1 - Relief Request RR-4-16, Request for Alternative to Implement Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Response to Request...2018-07-12012 July 2018 (Vcsns), Unit 1 - Relief Request RR-4-16, Request for Alternative to Implement Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping Response to Request... RC-18-0089, (Vcsns), Unit 1 - Relief Request RR-4-16, Request for Alternative to Implement Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping2018-07-11011 July 2018 (Vcsns), Unit 1 - Relief Request RR-4-16, Request for Alternative to Implement Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping RC-18-0084, Virgil C Summer Nuclear Station (Vcsns), Unit 1 - Relief Request RR-4-15, Request for Alternative to Implement Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Laws in Moderate Energy Class 2 or 3 Piping Response to Requ2018-07-0303 July 2018 Virgil C Summer Nuclear Station (Vcsns), Unit 1 - Relief Request RR-4-15, Request for Alternative to Implement Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Laws in Moderate Energy Class 2 or 3 Piping Response to Reques RC-18-0082, Relief Request RR-4-15, Request for Alternative to Implement Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping2018-07-0303 July 2018 Relief Request RR-4-15, Request for Alternative to Implement Code Case N-513-4, Evaluation Criteria for Temporary Acceptance of Flaws in Moderate Energy Class 2 or 3 Piping RC-18-0079, Vigil C. Summer Nuclear Station (Vcsns), Unit 1 - Request to Revise Technical Specifications to Correct an Administrative Error2018-06-29029 June 2018 Vigil C. Summer Nuclear Station (Vcsns), Unit 1 - Request to Revise Technical Specifications to Correct an Administrative Error RC-18-0074, Change of the Commitment Date of DRIB/105A&B Door Submittal2018-06-18018 June 2018 Change of the Commitment Date of DRIB/105A&B Door Submittal RC-18-0060, (VCSNS) - Request to Revise Technical Specifications to Correct Administrative Error2018-05-30030 May 2018 (VCSNS) - Request to Revise Technical Specifications to Correct Administrative Error RC-18-0064, (Vcsns), Unit 1 - Annual Commitment Change Summary Report2018-05-18018 May 2018 (Vcsns), Unit 1 - Annual Commitment Change Summary Report RC-18-0063, Submittal of 10 CFR 72.48 Biennial Report for the Independent Spent Fuel Storage Installation2018-05-0202 May 2018 Submittal of 10 CFR 72.48 Biennial Report for the Independent Spent Fuel Storage Installation RC-18-0056, (Vcsns), Unit 1 - Licensee Event Reports (2016-001-02, 2016-002-01, 2016-003-02) - Revision to Correct Typographical Errors2018-04-25025 April 2018 (Vcsns), Unit 1 - Licensee Event Reports (2016-001-02, 2016-002-01, 2016-003-02) - Revision to Correct Typographical Errors RC-18-0059, Annual Radioactive Effluent Release Report2018-04-25025 April 2018 Annual Radioactive Effluent Release Report RC-18-0046, License Amendment Request LAR-14-01541 Integrated Leak Rate Test Peak Calculated Containment Internal Pressure Change Request for Additional Information2018-04-19019 April 2018 License Amendment Request LAR-14-01541 Integrated Leak Rate Test Peak Calculated Containment Internal Pressure Change Request for Additional Information RC-18-0036, (Vcsns), Unit 1 - Relief Request RR-4-13, Use of a Risk-Informed Process as an Alternative for the Selection of Class 1 and Class 2 Piping Welds - Response to Request for Additional Information2018-04-0202 April 2018 (Vcsns), Unit 1 - Relief Request RR-4-13, Use of a Risk-Informed Process as an Alternative for the Selection of Class 1 and Class 2 Piping Welds - Response to Request for Additional Information RC-18-0041, Report of Status of Decommissioning Funding2018-03-28028 March 2018 Report of Status of Decommissioning Funding RC-17-0175, Correction to Amendment No. 170 Request to Revise Technical Specifications to Correct Administrative Error2018-01-31031 January 2018 Correction to Amendment No. 170 Request to Revise Technical Specifications to Correct Administrative Error RC-18-0006, Independent Spent Fuel Storage Installation Re Application for Order Approving Indirect Transfer of Control of Operating License and Combined Licenses2018-01-25025 January 2018 Independent Spent Fuel Storage Installation Re Application for Order Approving Indirect Transfer of Control of Operating License and Combined Licenses RC-17-0169, Notification of an Intended Change of a Commitment Date for Open Phase Condition Made in RC-14-00192017-12-11011 December 2017 Notification of an Intended Change of a Commitment Date for Open Phase Condition Made in RC-14-0019 RC-17-0182, (VCSNS) - Anchor Darling Double Disc Gate Valve Information and Status2017-12-11011 December 2017 (VCSNS) - Anchor Darling Double Disc Gate Valve Information and Status RC-17-0172, Notification of Personnel Changes2017-11-30030 November 2017 Notification of Personnel Changes RC-17-0161, Submittal of Change of the Commitment Date of DRIB/105A&B Door2017-11-28028 November 2017 Submittal of Change of the Commitment Date of DRIB/105A&B Door RC-17-0135, Annual Commitment Change Summary Report2017-11-0303 November 2017 Annual Commitment Change Summary Report RC-17-0123, Relief Request RR-4-13, Use of a Risk-Informed Process as an Alternative for the Selection of Class 1 and Class 2 Piping Welds2017-10-30030 October 2017 Relief Request RR-4-13, Use of a Risk-Informed Process as an Alternative for the Selection of Class 1 and Class 2 Piping Welds RC-17-0140, Transmittal of 10 CFR 50.59 Biennial Report2017-10-23023 October 2017 Transmittal of 10 CFR 50.59 Biennial Report RC-17-0107, (Vcsns), Unit 1 - Integrated Leak Rate Test Peak Calculated Containment Internal Pressure Change2017-10-0606 October 2017 (Vcsns), Unit 1 - Integrated Leak Rate Test Peak Calculated Containment Internal Pressure Change RC-17-0134, Response to Request for Supplemental Information, License Amendment Request - LAR-15-01424; Implementation of WCAP-15376-P-A, Revision 12017-09-27027 September 2017 Response to Request for Supplemental Information, License Amendment Request - LAR-15-01424; Implementation of WCAP-15376-P-A, Revision 1 RC-17-0126, Reply to a Notice of Violation, Per Inspection Report 05000395/20170022017-09-0606 September 2017 Reply to a Notice of Violation, Per Inspection Report 05000395/2017002 RC-17-0112, Special Report (Spr) 2017-007 Regarding Waste Gas Holdup System Explosive Gas Monitoring System Being Inoperable for Greater than Thirty Days2017-09-0101 September 2017 Special Report (Spr) 2017-007 Regarding Waste Gas Holdup System Explosive Gas Monitoring System Being Inoperable for Greater than Thirty Days RC-17-0069, (Vcsns), Unit 1 - Quality Assurance Approval Certificate No. 0479, Transmittal of the Quality Assurance Program Description2017-08-30030 August 2017 (Vcsns), Unit 1 - Quality Assurance Approval Certificate No. 0479, Transmittal of the Quality Assurance Program Description 2022-01-14
[Table view] Category:Status Report
MONTHYEARIR 05000395/20230062024-02-28028 February 2024 Annual Assessment Letter for Virgil C. Summer Nuclear Station - Report 05000395/2023006 ML23089A3892023-03-30030 March 2023 (Vcsns), Unit 1 - Decommissioning Funding Status Report ML21099A1072021-03-30030 March 2021 Report of Status of Decommissioning Funding ML21085A6252021-03-25025 March 2021 (VCSNS) Unit 1 - Decommissioning Funding Status Report RC-19-0012, NPDES Permit No. SC0030856 Renewal Application, Operational Status2019-01-31031 January 2019 NPDES Permit No. SC0030856 Renewal Application, Operational Status ML18213A1552018-07-23023 July 2018 Status Report on South Carolina Public Service Authority'S Position on the Termination of the COL for VCSNS Units 2 & 3 ML18206A2302018-07-23023 July 2018 Santee Cooper Letter to NRC Regarding the V.C. Summer, Units 2 & 3, Position on the Termination of the COL for VCSNS ND-18-0002, Submittal of Six (6) Month Status Report Regarding Implementation of the Overall Integrated Plan for Mitigation Strategies for Beyond Design Basis External Events2018-02-15015 February 2018 Submittal of Six (6) Month Status Report Regarding Implementation of the Overall Integrated Plan for Mitigation Strategies for Beyond Design Basis External Events ML17090A1122017-03-30030 March 2017 Report of Status of Decommissioning Funding RC-17-0037, Report of Status of Decommissioning Funding2017-03-28028 March 2017 Report of Status of Decommissioning Funding ML16243A4642016-08-29029 August 2016 Seventh Six-Month Status Report in Response to 03/12/2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-049) RC-15-0125, Fifth Six-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049)2015-08-24024 August 2015 Fifth Six-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049) RC-15-0126, Fifth 6-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051)2015-08-20020 August 2015 Fifth 6-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051) RC-15-0055, V.C. Summer, Report of Status of Decommissioning Funding2015-03-30030 March 2015 V.C. Summer, Report of Status of Decommissioning Funding ML15090A1972015-03-27027 March 2015 Report of Status of Decommissioning Funding RC-15-0031, Fourth 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation2015-02-27027 February 2015 Fourth 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation RC-14-0144, Third Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-04)2014-08-28028 August 2014 Third Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-04) RC-14-0141, Third 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation2014-08-28028 August 2014 Third 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation RC-14-0031, Second 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation2014-02-27027 February 2014 Second 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation RC-14-0030, South Carolina Electric & Gas Company'S Second Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External..2014-02-27027 February 2014 South Carolina Electric & Gas Company'S Second Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External.. RC-13-0117, 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation2013-08-28028 August 2013 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation RC-13-0123, V. C. Summer, Unit 1 - First Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order No. EA-12-049)2013-08-28028 August 2013 V. C. Summer, Unit 1 - First Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order No. EA-12-049) ML13091A0742013-03-28028 March 2013 Report of Status of Decommissioning Funding RC-13-0051, Report of Status of Decommissioning Funding2013-03-27027 March 2013 Report of Status of Decommissioning Funding ML1214500142012-05-23023 May 2012 NFPA 805 LAR Status Matrix - May 2012 ML0909103522009-03-30030 March 2009 Report of Status of Decommissioning Funding RC-09-0032, Report of Status of Decommissioning Funding2009-03-30030 March 2009 Report of Status of Decommissioning Funding ML0309805402003-03-31031 March 2003 Report of Status of Decommissioning Funding ML0224007812002-01-18018 January 2002 E-mail from Jacob Zimmerman, Bulletin 2001-01 Status Report 2024-02-28
[Table view] |
Text
Thomas D. Gatlin Vice President,Nuclear Operations (803) 345-4342 February 27, 2015 RC-15-0031 A SCANA COMPANY U. S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001
Dear Sir / Madam:
Subject:
VIRGIL C. SUMMER NUCLEAR STATION (VCSNS) UNIT 1 DOCKET NO. 50-395 OPERATING LICENSE NO. NPF-12 SOUTH CAROLINA ELECTRIC & GAS COMPANY (SCE&G) FOURTH 6-MONTH STATUS REPORT OF ORDER EA-12-051, ORDER MODIFYING LICENSES WITH REGARD TO REQUIREMENTS FOR RELIABLE SPENT FUEL POOL INSTRUMENTATION
References:
- 1. NRC Order Number EA-12-051, "Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation," dated March 12, 2012
[ML12054A682]
- 2. SCE&G's.Overall Integrated Plan in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051)," dated February 28, 2013 RC-13-0031 [ML13063A099]
On March 12, 2012, the Nuclear Regulatory Commission issued an order (Reference 1) to South Carolina Electric & Gas Company (SCE&G). Reference 1 was immediately effective and directs SCE&G to have a reliable indication of the water level in associated spent fuel storage pools.
Reference 1 requires submission of a 6-month status report following the submittal of the Overall Integrated Plan (Reference 2). The purpose of this letter is to provide the fourth 6-month status report pursuant to Section IV, Condition C.2, of Reference 1. SCE&G developed an Overall Integrated Plan (Reference 2), documenting the requirements to install reliable spent fuel pool level instrumentation, in response to Reference 1. Attachment I provides the fourth 6-month status report of milestone accomplishments since the submittal of the Overall Integrated Plan. This update includes any changes to the compliance method, schedule, or need for relief/relaxation and the basis.
This letter contains no new regulatory commitments. If you have any questions regarding this report, please contact Bruce L. Thompson at (803) 931-5042.
A DD SCEG I Virgil C.Summer Nuclear Station - P.0.Box 88 -Jenkinsville, South Carolina 29065
- T1803) 345.5209 - www.scana.com
Document Control Desk CR-12-01070 RC-15-0031 Page 2 of 2 I certify under penalty of perjury that the foregoing is true and correct.
Executed on Thomas D. Gatlin TS/TDG/rp
Attachment:
South Carolina Electric & Gas (SCE&G) Company Fourth 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation c: K. B. Marsh S. A. Byrne J. B. Archie N. S. Carns J. H. Hamilton J. W. Williams W. M. Cherry W. M. Dean V. M. McCree (w/attachment)
S. A. Williams (w/attachment)
M. A. Brown (w/attachment)
NRC Resident Inspector K. M. Sutton NSRC RTS (CR-12-01070)
File (815.07)
PRSF (RC-15-0031)
i Document Control Desk CR-12-01070 RC-15-0031 Attachment Page 1 of 10 VIRGIL C. SUMMER NUCLEAR STATION (VCSNS) UNIT I ATTACHMENT SOUTH CAROLINA ELECTRIC & GAS COMPANY (SCE&G) FOURTH 6-MONTH STATUS REPORT OF ORDER EA-1 2-051, ORDER MODIFYING LICENSES WITH REGARD TO REQUIREMENTS FOR RELIABLE SPENT FUEL POOL INSTRUMENTATION
- 1. Introduction SCE&G developed an Overall Integrated Plan (Reference 2) and first six-month status report (Reference 4), documenting the requirements to install reliable spent fuel pool level instrumentation (SFPLI), in response to Reference 1. This attachment provides an update of milestone accomplishments since submittal of the Overall Integrated Plan, including any changes to the compliance method, schedule, or need for relief/relaxation and the basis.
- 2. Milestone Accomplishments The following milestone(s) in section 3 have been completed since the development of the Overall Integrated Plan (Reference 2), and are current as of February 18, 2015.
VCSNS submitted a modification development, and an Engineering Change Request was completed in December 2014.
- 3. Milestone Schedule Status The following provides an update to the milestone schedule to support the Overall Integrated Plan. This section provides the activity status of each item and the expected completion date.
The target completion dates are planning dates subject to change as design and implementation details are developed.
The revised milestone target completion dates do not impact the order implementation date.
Target Revised Milestone Completion Activity Target Date Status Completion Date Submit 60 Day Status Report Oct 2012 Complete Submit Overall Integrated Plan Feb 2013 Complete Submit Response to RAIs on Overall Aug 2013 Complete Integrated Plan
Document Control Desk CR-12-01070 RC-15-0031 Attachment Page 2 of 10 Target Revised Completion Activity Target Milestone Date Status Completion Date Submit Response to RAIs on Overall Oct 2014 Complete Integrated Plan Submit 6 Month Updates:
Update 1 Aug 2013 Complete Update 2 Feb 2014 Complete Update 3 Aug 2014 Complete Update 4 Feb 2015 Complete Update 5 Aug 2015 Not Started Update 6 Feb 2016 Not Started Modifications:
Modification Development Jan 2014 Complete January 2015 Complete Procurement of Jun 2013 Completed Instrumentation Package Complete Engineering and Design Jul 2014 Complete January 2015 Commence Implementation Oct 2014 In Progress April 2015 Unit 1 Implementation Outage Oct 2015 Not Started Procedures:
Complete Procedures Development Feb 2015 In Progress May 2015 Training:
Develop Training Plan Feb 2015 In Progress June 2015 Training Complete Aug 2015 Not Started
- 4. Changes to Compliance Method As noted in previous updates (References 4, 5, and 12), there was one change to the compliance method as documented in the Overall Integrated Plan (Reference 2). The backup
I Document Control Desk CR-12-01070 RC-15-0031 Attachment Page 3 of 10 channel of the spent fuel pool level monitoring system will be a permanently installed channel instead of the portable channel described in Reference 2. The details of this change were provided in the station response to the Request for Additional Information (References 3 and 6).
There are no other changes to the compliance method to report in this update.
- 5. Need for Relief/Relaxation and Basis for the Relief/Relaxation SCE&G expects to comply with the order implementation date and no relief/relaxation is required at this time.
- 6. Open Items from Overall Integrated Plan and Draft Safety Evaluation Public meetings were held on November 26, 2013 and February 6, 2014 to discuss reliable spent fuel pool level instrumentation RAls based on binning (References 8, 9, and 10). The two bins are: generic RAIs to be answered by the vendor and plant specific.
VCSNS provided a response to all RAIs October 29, 2014 (Reference 13). Below is an update on plant specific RAIs 2, 5, 7, 13a, and 14 (as indicated by revision marks) which are listed in Reference 7. VCSNS will provide follow-up information for RAI 17 as it becomes available in a 6-month status update.
RAI #2 Please provide the following:
a) The design criteria to be used to estimate the total loading on the mounting device(s), including static weight loads and dynamic loads. Describe the methodology to be used to estimate the total loading, inclusive of design basis maximum seismic loads and the hydrodynamic loads that could result from pool sloshing or other effects that could accompany such seismic forces.
b) A description of the manner in which the level sensor (and stilling well, if appropriate) will be attached to the refueling floor and/or other support structures for each planned point of attachment of the sensing/waveguide assembly.
Indicate in a schematic the portions of the level sensor/waveguide that will serve as points of attachment for mechanical/mounting or electrical connections.
c) A description of the manner by which the mechanical connections will attach the level instrument to permanent SFP wall or floor structures so as to support the waveguide/level sensor assembly.
RAI #2 Response a) The potential spent fuel pool sloshing effects due to a postulated seismic event is being evaluated by VCS for the primary and backup channels. Applicable hydrodynamic wave impact forces will be included in the radar horn/pipe qualification and mounting load combinations.
Document Control Desk CR-12-01070 RC-15-0031 Attachment Page 4 of 10 The primary and backup channels consisting of the remote transmitter, horn, and waveguide piping will be mounted seismically. The mounting designs for the remote transmitter support and horn support were qualified considering the total weight of the waveguide piping and its components and the seismic accelerations for the building structure. To meet the design criteria for a Beyond Design Basis (BDB) event, the loading for the mounting supports will be generated considering Safe Shutdown Earthquake seismic accelerations.
The remote transmitter mounting support is qualified by a generic calculation using a simple C-channel steel section that is welded centrally on a steel base plate mounted on the outside west wall of the Fuel Handling Building (primary) and the east wall of the north Auxiliary Building stairwell (backup). The generic sensor mounting support was designed for generic enveloping seismic accelerations of 1 Og (horizontal) and 6.67g (vertical), which envelope the site seismic response spectra. The calculation further assumed an enveloping sensor cantilevered length.
VCS has decided to treat the waveguide pipe as Quality Related (QR) piping. This means the piping will meet ASME Sec III Class 2, but using non-code material, making it Seismic Category 1. The seismic spectra used were taken from both the Operating Basis Earthquake and Safe Shutdown Earthquake specific for VCS Unit 1 at the spent fuel pool and adjacent building (composite spectra). Differential building movement was taken into account (SAM - seismic anchor movement), along with the pool sloshing loads. The reactions at the support locations (from the analysis above) were reviewed to ensure they were bounded by the loads used in the vendor supplied calculations.
The horn mounting support will be qualified similarly to the remote transmitter support. It will be qualified by a generic calculation which has been verified to bound site specific geometry and seismic loadings. The generic design of the horn mounting support conservatively uses generic seismic accelerations of 10g (horizontal) and 6.67g (vertical). A visual representation of the pool edge mounting configuration for the radar horn is shown in the attached, Figure 1 and Figure 2. It also provides the mounting configuration.
All of the mounting supports for the waveguide piping are attached to either the outside west wall of the Fuel Handling Building, the 463 foot elevation of the Fuel Handling Building floor, or the east wall of the north Auxiliary Building stairwell.
The mounting design for the power control panels and auxiliary battery panels are qualified considering the total weight of the panel and its associated components and the seismic accelerations for the building structure. To meet this design criterion for a BDB event, the loading for the panels will be generated considering beyond design basis seismic accelerations.
b) & c) The waveguide piping assembly, horn, and remote transmitter are designed to attach to the spent fuel pool concrete floor, outside west wall of the Fuel Handling Building, and east wall of the north Auxiliary Building stairwell by means of mounting supports. These mounting supports consist of sensor support and horn support. Spacing of the mounting
Document Control Desk CR-12-01070 RC-1 5-0031 Attachment Page 5 of 10 supports complies with site specific specifications and standards and qualification restrictions for the waveguide pipe assembly. Figures 1 and 2 show the designed attachment points for the waveguide piping and horn assembly.
The remote transmitter mounting support is designed using a simple C-channel steel section that is welded centrally on a steel base plate on the east wall of the north Auxiliary Building stairwell (primary) and outside west wall of the Fuel Handling Building (backup). The base plate will be anchored to the wall with four (4) hilti bolts.
The horn mounting support is designed using a simple C-channel steel section that is welded on a base plate and anchored to the Fuel Handling Building concrete floor. The base plate will be anchored to the floor with four (4) hilti bolts.
The power control panel is designed to attach to a column in the Auxiliary Building (primary) and the outside west wall of the Fuel Handling Building (backup). The mounting of the power control panel consist of bolting the power control panel to two (2) sections of unistrut. The unistrut will be anchored to the column and wall using hilti bolts.
RAI #5 Please provide analysis of the maximum expected radiological conditions (dose rate and total integrated dose) to which the equipment located within the FH building exterior wall and the auxiliary building stairwell will be exposed. Also, provide documentation indicating how it was determined the electronics for this equipment is capable of 3
withstanding a total integrated dose of IXIO Rads. Discuss the time period over which the analyzed total integrated dose was applied.
RAI #5 Response The area above and around the pool will be subject to radiation dose in the event that the fuel becomes uncovered. The only parts of the instrument channels in the pool radiation environment are the metallic waveguide, horn, and fused silica glass horn cover which are not susceptible to the expected levels of radiation, and silicone elastomer moisture seal for the horn cover, which has associated radiation test data from the manufacture (see Areva Document No.
51-9202556-004, "Qualification Analysis of VEGAPULS 62 ER Through Air Radar"). The silicon elastomer seal has been tested for up to 7x1 08 rad, although above 1.6x1 08 rad the elastic modulus began to increase substantially. Nevertheless, even considering the conservative scenario above, the silicon elastomer test data demonstrates that the silicon is acceptable for the expected radiation dose for this application.
The electronics will be located in an area that is shielded from the direct shine from the fuel, and bounce and scatter effects above the pool. VCS is currently in the process of developing Dose Calculations for the areas in which the electronics of the systems will be located (Auxiliary Building 463 feet north stairwell, AB 463 feet General Area south of the equipment hatch, and at the Auxiliary Building Column). This calculation will contain does rate and total integrated dose
Document Control Desk CR-12-01070 RC-1 5-0031 Attachment Page 6 of 10 for each area. It is expected that this calculation will show that the dose in these areas is marginal enough for the electronics to withstand. VCS Calculation DC00030-057 is being revised to address radiological conditions in these areas. When this calculation is completed and this information becomes available, it will be provided in a 6-month status update.
RAI #7 Please provide information indicating the maximum expected relative humidity in the rooms in which the system electronics will be located under BDB conditions, with no AC power available to run HVAC systems, and whether the sensor electronics are capable of continuously performing required functions under this expected humidity condition.
RAI #7 Response The maximum humidity postulated for the spent fuel pool area is 100 percent relative humidity, saturated steam. The radar sensor electronics will be located outside of the spent fuel pool room in an area away from the steam atmosphere. The waveguide pipe can tolerate condensation formation on the inner wall surface, provided condensate pooling does not occur within the waveguide pipe. Condensate pooling is prevented by installing a weep hole(s) at the low point(s) in the waveguide pipe. VCSNS is still determining BDB conditions for the Fuel Handling Building exterior wall and the Auxiliary Building stairwell. The system electronics for the system are contained in the Power Control Panel. Since the power control panel is a NEMA 4X enclosure, it is designed for indoor or outdoor use to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water). Since the Power Control Panel will be able to withstand direct ingress of water, it is logical to assume that it would be able to withstand an environment of 0 to 100 percent humidity.
RAI #13 Please provide the following:
a) A description of how the spare battery will be maintained to ensure that it will be readily available.
b) The results of the calculation depicting the battery backup duty cycle requirements demonstrating that battery capacity is sufficient to maintain the level Indication function.
RAI #13 Response a) New Preventative Maintenance (PM) activities for the SFPLI system spare batteries were submitted to the VCS PM review group for approval after the vendor manual was received from the vendor and processed in accordance with VCSNS Procedures SAP-1280 and ES-507. The new PM task was generated in accordance with VCSNS
Document Control Desk CR-12-01070 RC-1 5-0031 Attachment Page 7 of 10 Procedure SAP-0143 Preventative Maintenance Program, input from AREVA, VCS Maintenance Department, EPRI templates, and industry OE.
The requested PM activities will verify spent fuel pool level indication function, Verify battery capability, and replace Lithium C-cell batteries periodically per the vendor manual. Upon approval, the following PM guidance will be implemented to ensure continued proper functioning of the VEGAPULS 62 ER Through Air Radar spent fuel pool level instrument:
- 1. Periodic checks should be made to compare the level indication and measurements certainty of the signal to the baseline values for the same water surface conditions, including distance from horn and water stillness. Verifying correct function of the sensor will involve the following three steps:
- a. Verify that the indication and current output (if used) is within the expected calibration tolerance for the loop, including the readout device, as compared
- b. The measurement reliability of the target echo is not less than 6 decibels (dB) below the baseline measurement reliability. The measurement reliability is accessed in the Diagnostics/Meas. reliability menu of the PLICSCOM.
Alternatively, using PACTware, the target echo amplitude is not more than 6 dB below the baseline.
- c. Place a target at a different distance than the water level and verify the indication changes in the correct direction.
- 2. Periodic checks should be made to verify proper operation of the battery backup capability. The backup power supply batteries should be replaced every surveillance period to ensure full battery capacity.
- 3. There are four (4) battery holders in the power control panel each holding two (2)
Lithium C-cell batteries. When replacing batteries, it is recommended to apply a piece of electrical tape along the side of the batteries to connect the two cells together to simplify subsequent removal of the rearmost cell.
b) The Power Control Panel and Auxiliary Battery Panel contain eight (8) Tadiran Model TL-5920 C-cell lithium batteries each that provide power. The battery storage life is reported by the manufacturer to be up to 20 years; however, the replacement interval recommended by AREVA is coincident with mandated surveillance of the level instrument. The battery life for worst case condition of 20 mA discharge rate is derived from the manufacturer technical data sheet in Areva Document 51-9202556-004 "Qualification Analysis of VEGAPULS 62 ER Through Air Radar".
Vendor analyses supports the battery capacity (at 20mA continuous discharge) can support approximately 130 hours0.0015 days <br />0.0361 hours <br />2.149471e-4 weeks <br />4.9465e-5 months <br /> and approximately 230 hours0.00266 days <br />0.0639 hours <br />3.80291e-4 weeks <br />8.7515e-5 months <br /> at negative 22 degrees Fahrenheit and 32 degrees Fahrenheit, respectively. The lifetime increases significantly at lower discharge rates or at higher temperatures. Lifetimes at the temperatures from
Document Control Desk CR-12-01070 RC-15-0031 Attachment Page 8 of 10 the Areva Document 51-9202556-004 "Qualification Analysis of VEGAPULS 62 ER Through Air Radar" for a 20 mA discharge rate are summarized in the table below.
Table 2-1: Backup Battery Lifetimes vs. Temperature Temperature Ampere-Hours to 2.0 Lifetime to 2.0 volts @ Lifetime at full voltage volts 20 mA (hours) @ 20mA (hours)
-30°C (-22°F) 2.7 135 131 00C (32-F) 4.8 240 233 25-C (77°F) 6.8 340 330 55°C (131 °F) 7.2 360 349 750C (167 0 F) 4.3 215 209 These calculated battery backup times demonstrate that the backup battery has sufficient capacity to support reliable instrument channel operation until off-site resources can be deployed by the mitigating strategies in response to Order EA-12-049.
The required battery backup capacity duration will further be demonstrated during post-modification testing.
RAI #14 Please provide analysis verifying the proposed instrument performance is consistent with these estimated accuracy normal and BDB values. Demonstrate the channels will retain these accuracy performance values following a loss of power and subsequent restoration of power.
RAI #14 Response The sensor, PLICSCOM display, power control panel, horn end of the waveguide, standard pool end and sensor end mounting brackets, and waveguide piping were successfully seismically tested in accordance with the requirements of the IEEE Standard 344-2004. The system was monitored for operability before and after the resonance search and seismic tests.
The factory acceptance testing demonstrated acceptable accuracy and performance capability.
The factory acceptance testing was performed utilizing a reflective target for the following conditions:
- normal operating conditions,
- simulated loss of normal AC power and automatic transfer to battery backup power,
- simulated BDB conditions with steam injection into the radar horn,
- simulated BDB conditions water introduction into the radar horn and waveguided pipe.
Document Control Desk CR-12-01070 RC-15-0031 Attachment Page 9 of 10 The requested analysis for verification of instrument performance is still in progress. Post modification testing will be performed to validate the accuracies tested during the factory acceptance testing. When this information becomes available it will be provided in a 6-month status update.
- 7. Potential Draft Safety Evaluation Impacts There are no potential impacts to the Draft Safety Evaluation identified at this time.
- 8. References The following references support the updates to the Overall Integrated Plan described in this attachment.
- 1. NRC Order Number EA-12-051, " Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation, "dated March 12, 2012
- 2. SCE&G's Overall Integrated Plan in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051)," dated February 28, 2013 (RC-13-0031) 3.' Robert E. Martin to Thomas D. Gatlin Letter: Virgil C. Summer Nuclear Station, Unit 1-Request for Additional Information Regarding Overall Integrated Plan for Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051) (TAC NO. MF1 173) dated July 29, 2013
- 4. SCE&G's 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation, dated August 28, 2013 (RC-13-0117)
- 5. SCE&G's Second 6-Month Status Report of Order EA-1 2-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation, dated February 27, 2014 (RC-14-0031)
- 6. Virgil C. Summer Nuclear Station, Unit 1 Response to Request for Additional Information Regarding Overall Integrated Plan for Reliable Spent Fuel Pool Instrumentation (Order Number EA-12-051) (TAC NO. MF1 173), dated August 28, 2013 (RC-13-0119)
- 7. Shawn Williams to Thomas D. Gatlin Letter: Virgil C. Summer Nuclear Station, Unit 1-Interim Staff Evaluation and Request for Additional Information Regarding the Overall Integrated Plan for Implementation of Order EA-12-051, Reliable Spent Fuel Pool Instrumentation (TAC NO. MF1 173), dated December 5, 2013
- 8. NRC (Nuclear Regulatory Commission 2013) Public Meeting on Reliable Spent Fuel Pool Instrumentation-StaffEvaluations of Licensee Plans for Addressing Order EA- 12-051, November 26, 2013 Rockville, MD: NRC
- 9. NEI (Nuclear Energy Institute 2013) Spent Fuel Pool Instrumentation Order (EA-12-051)
RAIs Binning Nov. 26, 2013 Washington, DC: NEI
Document Control Desk CR-1 2-01070 RC-1 5-0031 Attachment Page 10 of 10
- 10. NRC (Nuclear Regulatory Commission 2013) Public Meeting on Reliable Spent Fuel Pool Instrumentation-StaffEvaluations of Licensee Plans for Addressing Order EA- 12-051, February6, 2014 Rockville, MD: NRC
- 11. SCE&G's Virgil C. Summer Nuclear Station (VCSNS) Unit 1 Specification for Fukushima (FLEX) SFP Level Instrumentation System SP-1 000, Revision 1, dated February 4, 2014
- 12. SCE&G's Third 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation, dated August 28, 2014 (RC-14-0141)
- 13. SCE&G's Response to Request for Additional Information - Overall Integrated Plan in Response to Commission Order Modifying License Requirements for Reliable Spent Fuel Pool Instrumentation (Order No. EA-12-051), dated October 29, 2014 (RC-14-0173)