MONTHYEARML15120A0812015-04-30030 April 2015 Acceptance Review for TACs MF6094 & MF6095 - Limerick Units 1 and 2 - Submittal of Relief Request to Use Code Case OMN-18 Project stage: Acceptance Review ML15202A3782015-07-21021 July 2015 Draft Request for Additional Information Project stage: Draft RAI 2015-04-30
[Table View] |
|
---|
Category:Acceptance Review Letter
MONTHYEARML23086A0822023-03-27027 March 2023 Acceptance of Requested Licensing Action for Exemption Request to Support Digital Modernization Project Installation ML22339A0642022-12-0909 December 2022 Generation Station, Unit Nos. 1 and 2 Acceptance of Requested Licensing Action Replacement of Existing Safety-Related Analog Control Systems with a Single Digital Plant Protection System ML22320A1132022-11-21021 November 2022 Generation Station, Units 1 and 2 - Supplemental Information Needed for Acceptance of Digital Instrumentation and Controls License Amendment Requests ML22112A2152022-03-28028 March 2022 Limerick_Acceptance Review TS Change to Correct Nonconservative Technical Specification Table 3.3.3-1 ML21140A0842021-05-19019 May 2021 Acceptance of Requested Licensing Action Revision to Appendix C License Conditions in Accordance with the Requirements of 10 CFR 50.69 (E-mail) ML21111A0312021-04-20020 April 2021 Application to Modify 50.69 Categorization to Implement an Alternate Defense-in-Depth Categorization Process, an Alternate Pressure Boundary Categorization Process, and an Alternate Seismic Tier 1 Categorization Process ML21077A1772021-04-0808 April 2021 Withdrawal of Requested Exemption from Certain Requirement in 10 CFR 50.55a (Epids L-2021-LLE-0014, 0015, & 0016) ML20304A1432020-10-30030 October 2020 Acceptance Review: Relocation of Pressure and Temperature Limit Report ML20273A1582020-09-29029 September 2020 Acceptance Review: to Adopt TSTF-582, Reactor Pressure Vessel Water Inventory Control (RPV WIC) Enhancements ML20268B2362020-09-24024 September 2020 Acceptance Review: Relief Requesting Residual Heat Removal Heat Exchanger Category C-A and C-B Examinations ML20092G8352020-04-0101 April 2020 Acceptance Review - TS Change 3.10.8, Inservice Leak - TSTF-484 ML20091N0492020-03-27027 March 2020 Acceptance Review: TS Change for Testing of the SRVs to Retain the Frequency and Associated Relief Requests in the IST Program (EPIDs L-2020-LLA-0052 and L-2020-LLA-0043) ML19357A0892019-12-23023 December 2019 Acceptance Review: Technical Specification 40.5 Requirements to Reflect the Allowance Provided in 10 CFR 50.69(b)(1)(v) to Perform Alternative Treatement of SSC J(Epid: L-209-LLA-263) ML19248B7322019-09-0505 September 2019 Letter to R. Libra Alternative Request Pertaining to Dry Shielded Canisters Equipped with Boral Neutron Absorber Plates - Accepted for Review ML19239A1552019-08-26026 August 2019 Acceptance Review for Limerick - Relocation of Chlorine and Toxic Gas Detection System TSs License Amendment Request ML19030A1472019-01-30030 January 2019 Supplemental Information Needed for Acceptance of Requested Licensing Action to Adopt Risk-Informed Completion Times in Accordance with TSTF-505, Revision 2 ML18295A5312018-10-22022 October 2018 Acceptance Review: Relief Request I4R-08, Revision 1 for the Fourth Inservice Inspection Interval of Limerick Generating Station (LGS) Units 1 and 2 ML18052B0762018-02-21021 February 2018 Acceptance Review: Revise Technical Specifications to Lower the Minimum Standby Liquid Control System Pump Flowrate ML17234A5282017-08-25025 August 2017 Acceptance of Requested Licensing Action Adoption of Title 10 of the Code of Federal Regulations Section 50.69 ML17137A1542017-05-16016 May 2017 Acceptance Review for Relief Request Associated with Reactor Pressure Vessel Nozzle Repairs ML17009A3792017-01-0909 January 2017 Acceptance of Requested Licensing Action Regarding Amendment-Partial Length Fuel Rod Burn-up ML17009A2932017-01-0909 January 2017 Acceptance of Requested Licensing Action Regarding Amendment-Partial Length Fuel Rod Burn-up ML17003A3292017-01-0303 January 2017 Acceptance Review - Limerick Unit 2 - Safety Limit Minimum Critical Power Ratios ML16319A1262016-11-14014 November 2016 Acceptance Review - Limerick 1 and 2 - Relief Request GVRR-8 ML16237A0362016-08-24024 August 2016 Acceptance Review: Limerick 1 & 2 - TS ISI and IST Program Requirements (CACs MF8193 and MF8194) ML16055A3692016-02-24024 February 2016 Acceptance Review: Limerick 1 & 2 - Reduce Steam Dome Pressure Amendment Request (CACs MF7263 and MF7264) ML15341A0232015-12-0707 December 2015 Acceptance Review for CAC MF7101 - Limerick Unit 1 - Safety Limit Minimum Critical Power Ratio ML15120A0812015-04-30030 April 2015 Acceptance Review for TACs MF6094 & MF6095 - Limerick Units 1 and 2 - Submittal of Relief Request to Use Code Case OMN-18 ML14329B2982014-11-25025 November 2014 Email- Acceptance Review for TACs MF5133 & MF5134 - Limerick Units 1 and 2 - Add New LCOs 3.0.5 and 3.0.6 ML14212A3802014-07-31031 July 2014 Acceptance Review for TACs MF4412 & MF4413 - Limerick Units 1 and 2 - TSTF-523, Generic Letter 2008-01 - Managing Gas Accumulation ML13101A0482013-04-11011 April 2013 Acceptance Review for TACs ME1399 & ME1400 - Limerick Units 1 and 2 - Eliminate Certain TS Reporting Requirements ML12331A0382012-11-26026 November 2012 Acceptance Review for License Amendment Request to Relocate MOV TOL Protection to TRM ML1119403082011-07-13013 July 2011 Acceptance Review of License Amendment Request to Include an Alternate Method of Verifying Drywell Leakage - TAC Nos ME6521 & ME6522 ML1116804112011-06-17017 June 2011 Acceptance Review for Exelon Threshold Determination Request (TAC ME6269 - ME6287) ML1113101262011-05-11011 May 2011 Acceptance Review of Limerick License Amendment Request Regarding TSTF-514, RCS Leakage Detection Instrumentation, TAC Nos. ME5993 & ME5994 ML1021502822010-08-0303 August 2010 Acceptance Review of Limerick LAR Regarding HPCI Dt Isolation Setpoint Change - TACs ME4171/ME4172 ML1008800852010-07-21021 July 2010 Fleet - Acceptance Review Implementation of Emergency Action Level Schemes Developed from NEI 99-01m Rev. 5 ML1005400432010-02-22022 February 2010 Acceptance Review of Limerick Relief Request I3R-13, Pressure Testing of Primary Containment Gas Piping ML0924700432009-09-0303 September 2009 3 Acceptance Review Results Request to Use Specific Provisions from a Later Edition of the ASME Boiler and Pressure Vessel Code 2023-03-27
[Table view] Category:E-Mail
MONTHYEARML24026A2922024-01-26026 January 2024 Request for Additional Information Regarding Limerick Digital Instrumentation and Controls License Amendment Request ML23331A0062023-11-22022 November 2023 (External Sender) Supplement - Limerick Security Rule Exemption Request ISFSI Docket No. Reference ML23311A2412023-11-0707 November 2023 NRR E-mail Capture - NRC Notification to the Commonwealth of Pennsylvania Re. Limerick Generating Station, Units 1 and 2 Amendment - Control Room Ventilation System Technical Specifications ML23304A0192023-10-30030 October 2023 NRR E-mail Capture - Final RCI - Constellation Energy Generation, LLC - Limerick 1 & 2 - Exemption from Security Rule (L-2023-LLE-0026) ML23276B4642023-10-0303 October 2023 NRR E-mail Capture - NRC Request for Additional Information Limerick TSTF-477 LAR ML23255A2872023-09-12012 September 2023 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of Alternative to Use the Successive Inspection Requirements of BWRVIP-75-A ML23248A1282023-09-0101 September 2023 NRR E-mail Capture - Action: Opportunity to Review and Comment on a New NRC Information Collection, 10 CFR Part 50.55a, Codes and Standards (3150-XXXX) ML23237B3972023-08-24024 August 2023 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of Alternative Request to Use Updated BWRVIP Guidelines ML23208A1942023-07-27027 July 2023 NRR E-mail Capture - Limerick Generating Station - Audit Plan for TSTF-477 LAR Review (L-2022-LLA-0174) ML23202A0682023-07-21021 July 2023 NRR E-mail Capture - NRC Request for Additional Information Re. TSTF-477 LAR ML23201A1262023-07-18018 July 2023 Additional RAIs for Limerick Generation Station, Units 1 and 2 - LAR and Exemption Request for Digital I&C Installation Support ML23173A0632023-06-20020 June 2023 RAIs for Limerick Generation Station, Units 1 and 2 - LAR and Exemption Request for Digital I&C Installation Support ML23102A1642023-04-12012 April 2023 Generation Station, Unit No. 2 Potential Emergent Relief Request for HPCI IST (EPID L-2023-LLR-0015) - Closure E-mail Dated 4/12/2023 ML23125A0522023-03-31031 March 2023 NRR E-mail Capture - Clean OL Pages for 50.69 LAR ML23089A1602023-03-30030 March 2023 NRR E-mail Capture - NRC Notification to the Commonwealth of Pennsylvania Re. Limerick Generating Station, Units 1 and 2 Amendment - Alternative 10 CFR 50.69 Categorization Approaches ML23086B9282023-03-27027 March 2023 Acceptance of Requested Licensing Action for License Amendment Request to Support Digital Modernization Project Installation ML23086A0822023-03-27027 March 2023 Acceptance of Requested Licensing Action for Exemption Request to Support Digital Modernization Project Installation ML22354A2622022-12-20020 December 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request - Acceptance of Request to Use Certain Provisions of the 2019 Edition of the ASME BPV Code, Section XI ML23060A1662022-12-20020 December 2022 Acceptance Review: Adopt TSTF-477, Revision 3-Acceptance Letter ML22200A0782022-07-19019 July 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Fleet Request to Use Honeywell Mururoa V4F1 R Supplied Air Suits ML22172A0752022-06-17017 June 2022 Response: Review and Feedback on Draft Limerick Digital License Amendment Request (L-2020-LRM-0041) ML22136A0032022-05-13013 May 2022 NRR E-mail Capture - NRC Request for Additional Information - Limerick License Amendment Request (L-2021-LLA-0042) ML22124A2862022-05-0404 May 2022 Information Needed to Provide Substantive Feedback on Human Factors Engineering Supporting the Planned Limerick Digital I&C License Amendment Request ML22089A1172022-03-30030 March 2022 Additional Comments and Questions on Constellation'S March 31st Presentation ML22112A2152022-03-28028 March 2022 Limerick_Acceptance Review TS Change to Correct Nonconservative Technical Specification Table 3.3.3-1 ML22089A1162022-03-28028 March 2022 Comments and Questions on Constellation'S March 31st Presentation ML22041B5362022-02-10010 February 2022 NRR E-mail Capture - Constellation Energy Generation, LLC - Request for Additional Information Regarding Fleet License Amendment Request to Adopt TSTF-541 ML22034A0142022-02-0202 February 2022 NRR E-mail Capture - Audit Plan Supplement for LIM 50.69 LAR (L-2021-LLA-0042) ML22028A1832022-01-24024 January 2022 NRR E-mail Capture - Audit Plan Supplement for LIM 50.69 LAR (L-2021-LLA-0042) ML22020A0642022-01-13013 January 2022 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Proposed Fleet Alternative for Repair of Water Level Instrumentation Partial Penetration Nozzles ML22005A1812022-01-0505 January 2022 NRR E-mail Capture - Staff'S Questions Pertaining to Limerick Generating Station Digital Modernization Project LAR Pre-submittal Meeting Slides December 7, 2021 ML21301A0672021-10-28028 October 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Acceptance of License Amendment Request to Adopt TSTF-541 ML21295A0362021-10-20020 October 2021 NRR E-mail Capture - Supplement to Limerick 50.69 Audit Plan Dated October 1, 2021 (L-2021-LLA-0042) ML21286A0302021-10-13013 October 2021 Staff'S Questions Pertaining to Limerick Generating Station Digital Modernization Project LAR Pre-submittal Meeting Slides October 20, 2021 ML21256A1902021-09-10010 September 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding License Transfer Application ML21252A0482021-09-0707 September 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Fleet Alternative Request for Repair of Water Level Instrumentation Partial Penetration Nozzles ML21215A3502021-08-0303 August 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Acceptance of License Amendment Request to Adopt TSTF-554 ML21154A0132021-05-28028 May 2021 NRR E-mail Capture - Extension of Comment Period for the Exelon Generation Company, LLC License Transfer Application ML21154A0142021-05-28028 May 2021 NRR E-mail Capture - Extension of Comment Period for the Exelon Generation Company, LLC License Transfer Application ML21154A0112021-05-28028 May 2021 NRR E-mail Capture - Extension of Comment Period for the Exelon Generation Company, LLC License Transfer Application ML21144A2132021-05-24024 May 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding License Transfer Application ML21140A0842021-05-19019 May 2021 Acceptance of Requested Licensing Action Revision to Appendix C License Conditions in Accordance with the Requirements of 10 CFR 50.69 (E-mail) ML21117A0442021-04-26026 April 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Proposed Fleet Alternative to Documentation Requirements for Pressure Retaining Bolting ML21111A0312021-04-20020 April 2021 Application to Modify 50.69 Categorization to Implement an Alternate Defense-in-Depth Categorization Process, an Alternate Pressure Boundary Categorization Process, and an Alternate Seismic Tier 1 Categorization Process ML21084A2532021-03-24024 March 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Acceptance of License Transfer Application ML21070A0062021-03-10010 March 2021 Acceptance Review to Adopt TSTF-205-A Revision of Calibration, Channel Functional Test, and Related Definitions ML21062A0652021-03-0101 March 2021 NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Proposed Fleet Alternative to Documentation Requirements for Pressure Retaining Bolting ML21049A2572021-02-18018 February 2021 Request for Additional Information Byron/Dresden Proposed Changes to Site Emergency Plans to Support Post-Shutdown and Permanently Defueled Conditions (EPID-2020-LLA-0240 & EPID-2020-LLA-0237) 2024-01-26
[Table view] |
Text
From: Ennis, Rick Sent: Thursday, April 30, 2015 9:36 AM To: Tom Loomis Cc: Glenn Stewart (glenn.stewart@exeloncorp.com); David Helker
Subject:
Acceptance Review for TACs MF6094 & MF6095 - Limerick Units 1 and 2 -
Submittal of Relief Request to Use Code Case OMN-18
- Tom, By letter dated April 13, 2015 (ADAMS Accession No. ML15104A531), Exelon Generation Company, LLC submitted a relief request for Limerick Generating Station (LGS), Units 1 and 2.
The proposed relief request concerns the use American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (Code) Case OMN-18, Alternate Testing Requirements for Pumps Tested Quarterly Within +/-20% of Design Flow.
The purpose of this e-mail is to provide the results of the NRC staffs acceptance review of this relief request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review.
The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.
Pursuant to Sections 50.55a(z)(1) and 50.55a(z)(2) of Title 10 of the Code of Federal Regulations (10 CFR), the applicant shall demonstrate that the proposed alternatives would provide an acceptable level of quality and safety, or that compliance with the specified requirements of Section 50.55a would result in hardship or unusual difficulty without a compensating increase in the level of quality or safety.
The NRC staff has reviewed your application and concluded that it does provide technical information in sufficient detail to enable the staff to proceed with its detailed technical review and make an independent assessment regarding the acceptability of the proposed relief request in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the NRC staffs ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. You will be advised of any further information needed to support the NRC staffs detailed technical review by separate correspondence.
If you have any questions, please contact me at (301) 415-1420.
Richard B. Ennis, Senior Project Manager Plant Licensing Branch I-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation