Summary of 831220 Meeting W/Util & Impell Corp in Bethesda, MD Re Outstanding Environ Qualification Issues
ML13333B996
Person / Time
Site: San Onofre 
Issue date: 01/17/1984
From: Paulson W
Office of Nuclear Reactor Regulation
To:
Office of Nuclear Reactor Regulation
References
LSO5-84-01-023, LSO5-84-1-23, TAC-42516, NUDOCS 8401180244
Download: ML13333B996 (22)


Text

January 17, 1984 Docket No. 50-206 LSO5-84-01-023 LICENSEE:

SOUTHERN CALIFORNIA EDISON (OMPANY FACILITY:

San Onofre Nuclear GeneratingStation, Unit No. 1

SUBJECT:

SUMMARY

OF DECEMBER 20, 1983 MEETING On December 20, 1983, the NRC staff met with representatives of Southern California Edison Company in Bethesda, Maryland. The purpose of the meeting was to discuss and resolve the outstanding environmental quali fication issues for San Onofre Unit No. 1. A list of attendees is enclosed (Enclosure 1).

The areas discussed were (1) the deficiencies identified in the Franklin Research Center Technical Evaluation Report, (2) the licensee's program for complying with the requirements set forth in 10 CFR 50.49, and (3) the licensee's justification for continued operation as required. is a table showing the status of resolution of environmental equipment qualification prepared by the licensee as the basis for dis cussion.

The licensee indicated subsequent to the meeting that it is their intention to document the results of the meeting by January 31, 1984.

Original signed by Walter A. Paulson, Project Manager Operating Reactors Branch #5 Division of Licensing

Enclosures:

1. List of Attendees
2. Table by licensee cc w/enclosure See next page DISTRIBUTION Docket NRC PDR Local PDR ORB #5 Reading DCrutchfield WPaulson OELD JTaylor EJordan ACRS (10)

NSIC DL 5

D CC list WPaulson:jc D

chfield NRC Participants (l/1 /84 1/f /84 84011E0244 840117 PDR ADOCK 05000206 PDR

Mr. K. Baskin cc Charles R. Kocher, Assistant General Counsel James Beoletto, Esquire Southern California Edison Company Post Office Box 800 Rosemead, California 91770 David R. Pigott Orrick, Herrington & Sutcliffe 600 Montogmery Street San Francisco, California 94111 Harry B. Stoehr San Diego Gas & Electric Company P. 0. Box 1831 San Diego, California 92112 Resident Inspector/San Onofre NPS c/o U.S. NRC P. 0. Box 4329 San Clemente, California 92672 Mayor City of San Clemente San Clemente, California 92672 Chairman Board of Supervisors County of San Diego San Diego, California 92101 California Department of Health ATTN:

Joseph 0. Ward, Chief Radiation Control Unit Radiological Health Section 714 P Street, Room 498 Sacramento, California 95814 U.S. Environmental Protection Agency Region IX Office ATTN:

Regional Radiation Representative 215 Freemont Street San Francisco, California 94111 John B. Martin, Regional Administrator Nuclear Regulatory Commission, Region V 1450 Maria Lane Walnut Creek, California 94596

ATTENDANCE LIST DECEMBER 20, 1983 MEETING NRC STAFF AND SOUTHERN CALIFORNIA EDISON COMPANY Name Affiliation R. L. Phelps SCE Terry Maxey Impell Corporation A. C. Llorens SCE R. W. Krieger SCE A. S. Masciantonis NRC Paul Shemanski NRC Bob LeGrange NRC Tommy Le NRC Jose Calvo NRC J. Burdoin NRC E. McKenna NRC Rudy Karsch NRC W. Paulson NRC

Southern California Edison Environmental Equipment Qualification San Onofre Nuclear Generating Station TER Resolution Status Unit 1 Page 1 Component Type: Motorized Valve Actuators SCE SONGS-1 Equipment NRC/TER Item #

ID Number Description Category Deficiencies Response/Resolution 10(8)

MOV-850A,B,C Limitorque m/n SMA-1-40 IIA Similarity; Aging; Qualifiable based on valve oper w/Reliance m/n 400524-FQ Qualified Life/Replacement ating requirements. Additional Schedule; Aging Program evaluation to address aging, qualified life/replacement schedule will be performed.

15(1)

MOV/LCV 1OOBC Limitorque m/n SMB-00-10 IIA Similarity; Aging; Additional evaluation to addr w/Reliance m/n 400524-FQ Qualified Life/Replacement deficiencies based on vendor type Schedule testing is being performed.

Also evaluating qualifiability based on valve operating requirements.

15(2)

MOV/LCV 11000 Limitorque m/n SMB-00-10 IIA Similarity; Aging; Additional evaluation to address w/Peerless m/n KS45153 Qualified Life/Replacement deficiencies based on vendor type Schedule testing is being performed.

Also evaluating qualifiability based on valve operating requirements.

18(5)

MOV-18,19 Limitorque m/n SMB-00 IIA Similarity; Aging; Additional evaluation to address w/Peerless Qualified Life/Rep'lacement deficiencies based on vendor type Schedule; Aging Program testing is being performed.

Also evaluating qualifiability based on valve operating requiremen 59(7)

MOV-720A,B Limitorque m/n SMB-00 IIA Similarity; Aging; Additional evaluation to address Qualified Life/Replacement deficiencies based on vendor type Schedule; Aging Program testing is being performed.

Evaluation will address radiation only environments.

12(6)

MOV-866A,B Limitorque m/n SMB-00 IIA Similarity; Aging; Additional evaluation to address w/Peerless m/n P11766 Qualified.Life/Replacement deficiencies based on vendor type Schedule; Aging Program testing is being performed.

0755g / 12-09-83

Southern California Edison Environmental Equipment Qualification San Onofre Nuclear Generating Station TER Resolution Status Unit I Page 2 Component Type: Motorized Valve Actuators (Cont'd.)

SCE SONGS-1 Equipment NRC/TER Item # ID Number Description Category Deficiencies Response/Resolution 20(3)

MOV-356,357,358 Limitorque m/n SMB-00-25 IIA Similarity; Aging; Additional evaluation to address w/Reliance m/n 709571-JY Qualified Life/Replacement deficiencies based on vendor type Schedule; Aging Program testing is being performed.

23(4)

MOV-880 Limitorque m/n SMB-00

.IIA NA Exempt from qualification. Valve w/Peerless not required to operate.

0 0755g / 12-09-83

Southern California Edison Environmental Equipment QualIfication San Onofre Nuclear Generating Station TER Resolution Status Unit 1 Page 3 Component Type: Solenoid Valves SCE SONGS-1 Equipment NRC/TER Item //

ID Number Description Category Deficiencies Response/ResoluLion 19(12)

FCV-1115D,E,F ASCO m/n B8300 B56R1 IV Documentation not provided Valve internals rebuilt [see SCE letters 4/4/81 and 4/18/81].

Maintenance to-be performed at 5-year intervals.

26(60)

CV-82(SV-128)

ASCO m/n WPLB8300 B61RV IIA Documentation not adequate Evaluating similarity of valve to other tested valves.

Qualli fication evaluation will also consider valve operating requirements.

(62).

CV-114(SV-118)

ASCO m/n U8302 C26R IIA Documentation not adequate Evaluating similarity of valves to other tested valves.

Quali fication evaluaLion will also consider valve operating requirements.

28(13)

CV-102,104,106 ASCO m/n WPLB8300 B61R IIA Documentation not adequate Evaluating similarity of valves (SV-108,110,112) to other tested valves. Quali fication evaluation will also consider valve operating requirements.

29(67)

CV-103,105,107 ASCO m/n 8300 B61 IIA Documentation not adequate Evaluating similarity of valve (SV-109,111,113) to other tested valves.

Quali-O fication evaluation will also consider valve operating requirements.

30(68)

CV-146,147 ASCO m/n WPLB8300 B59 IIA Documentation not adequate Evaluating similarity of valves (SV-1212-6, to other tested valves.

Quall 1212-7) fication evaluation will also consider valve operating requirements.

0755g / 12-09-83

Southern California Edison Environmental Equipment Qualification San Onofre Nuclear Generating Station TER Resolution Status Unit 1 Page 4 Component Type: Solenoid Valves (Cont'd.)

SCE SONGS-1 Equipment NRC/TER Item #

ID Number Description Category Deficiencies Response/Resolution 31(66)

SV-1212-8, ASCO m/n HTX821027 IIA Documentation not adequate Replaced with qualified Target 1212-9 Rock valves.

32(71)

CV-117,118,119 ASCO m/n WP831735 IIA Documentation not adequate Replaced with qualified Target (SV-119,120,121)

Rock valves.

33(71)

CV-120,121,122 ASCO m/n WP831735 IIA Documentation not adequate Replaced with qualified Target (SV-122,123,124)

Rock valves.

.34(67)

CV-123 ASCO m/n WPB300 B61R IIA Documentation not adequate Replaced with qualified Target (SV-125)

Rock valves.

35(10)

CV-537 ASCO m/n WP HTX832093 IIA Documentation not adequate Evaluating similarity of valves to other tested valves. Quali fication evaluation will also consider valve operating requirements.

36(61)

CV-115 ASCO m/n WPLB8300 B64RU IIA Documentation not adequate Evaluating similarity of valves (SV-126) to other tested valves.

Quali fication evaluation will also consider valve operating requirements.

39(63)

POV-9,10 ASCO m/n 8345C11 HA Documentation not adequate Evaluating similarity of valves (SV-29,30) to other tested valves.

Quali fication evaluation will also consider valve operating requirements.

40(64)

CV-400116 ASCO m/n WPLB8300 B59RF IIA Documentation not adequate Evaluating similarity of valves (SV-19,127) to other tested valves. Quali fication evaluation will also consider valve operating requirements.

n7;;n / 19_0Q0Ai

Southern California Edison Environmental Equipment Qualification San Onofre Nuclear Generating Station TER Resolution Status Unit 1 Page 5 Component Type:

Solenoid Valves (Cont'd.)

SCE SONGS-1 Equipment NRC/TER Item _

ID Number Description Category Deficiencies Response/Resolution 41(70)

CV-10 (SV-28)

ASCO m/n WPLB8300 B59 IIA Documentation not adequate Evaluating similarity of valves to other tested valves.

Quali fication evaluation will also consider valve operating requirements.

42(10)

CV-533,536 ASCO m/n WPHTX832093 IIA.

Documentation not adequate Evaluating similarity of valves to other tested valves. Quali fication evaluation will also consider valve operating requirements.

43(11)

CV-534,535 ASCO m/n WPHT832093 IIA Documentation not adequate Evaluating similarity of valves to other tested valves.

Quali fication evaluation will also consider valve operating requirements.

46(69)

CV-287 ASCO IIA Documentation not adequate Evaluating similarity of valves to other tested valves.

Quali-fication evaluation will also consider valve operating requirements.

47(68)

CV-202,203,204 ASCO m/n WPLB8300 B59 IIA Documentation not adequate Evaluating similarity of valves (SV-126) to other tested valves. Quali fication evaluation will also consider valve operating requirements.

0755g / 12-09-83

Southern California Edison Environmental Equipment Qualification San Onofre Nuclear Generating Station TER Resolution Status Unit 1 Page 6 Component Type:

Solenoid Valves (Cont'd.)

SCE SONGS-1 Equipment NRC/TER Item #

ID Number Description Category Deficiencies Response/Resolution 48(11)

CV-532 ASCO m/n WPHTX832093 IIA Documentation not adequate Evaluating similarity of valves to other tested valves.

Quali fication evaluation will also consider valve operating requirements.

76(65)

CV-530,531 ASCO 8316 IIA Documentation not adequate Evaluating similarity of valve*

to other tested valves. Quali fication evaluation will also consider valve operating requirements.

77(65)

CV-545,546 ASCO 8316 IIA Documentation not adequate Evaluating similarity of valves to other tested valves. Quali fication evaluation will also consider valve operating requirements.

44(17)

CV-525,527 Atkomatic m/n 3101 IIA Documentation not adequate Will be replaced as part of Efcomatic valve modification.

45(19)

CV-526,528 Atkomatic m/n 3101 IIA Documentation not adequate Will be replaced as part of Efcomatic valve modification.

49(16)

CV-515,516 Atkomatic m/n 3101 IIA Documentation not adequate Will be replaced as part of Efcomatic valve modification.

37(14)

SV-702B,D Morotta m/n MV583H-4A IIA Documentation not adequate Exempt from qualification.

38(15)

SV-702A,C Morotta m/n MV583H-4A IIA Documentation not adequate Exempt from qualification.

57(9)

CV-76,77,78,79 Valvair m/n 5682-2 IIA Documentation not adequate Additional evaluation to address (SV-85,86,87,88) radiation-only environment is being performed.

nA7Tr r I 1I n00 n0'

Southern California Edison Environmental Equipment Qualification San Onofre Nuclear Generating Station TER Resolution Status Unit 1 Page 7 Component Type: Transmitters:

Flow/Level/Pressure/Temperature SCE SONGS-1 Equipment NRC/TER Item #

ID Number Description Category Deficiencies Response/Resolution 63(21)

FT-2002-A,B,C Controlatron m/n 240N3CS40 IIA Documentation not adequate Replaced with fully qualified equipment (N-El0 series). Docu mentation is being prepared as part of TMI modification program.

3(30)

PT-430,431 Foxboro m/n N-EllGM IIA Documentation not adequate; Qualified based on type testing Similarity; Aging; Qualified completed in May 1983.

Life/Replacement Schedule; Aging Program; Duration; Profile Envelope; Test Sequence 50(34)

PT-1120A,B,C Foxboro m/n N-ElGM HA Documentation not adequate; Qualified based on type testing PT-1121A,B,C Similarity; Aging; Qualified completed in May 1983.

Life/Replacement Schedule; Aging Program 64(28)

LT-450X,451X, Foxboro m/n N-El3DM IIA Documentation not adequate; Qualified based on type testing 452X Similarity; Aging; Qualified completed in May 1983.

Life/Replacement Schedule; Aging Program; Duration; Profile Envelope; Test Sequence 4(29)

LT-430,431,432 Foxboro m/n E13DH IIA Documentation not adequate; Qualifiable. Documentation based Similarity; Aging; Qualified on vendor type testing will be Life/Replacement Schedule; performed.

Aging Program; Duration; Profile Envelope; Test Sequence 2(18)

FT-456,457,458 Foxboro m/n 613DM IIA Documentation not adequate; Replaced with fully qualified Aging; Qualified Life/

equipment (N-E1 series).

Replacement Schedule; Aging Program 9(22)

FT-912,913,914 Foxboro m/n 630-2AS IIA Documentation not adequate To be replaced with qualified transmitters.

0755g / 12-09-83

Southern California Edison Environmental Equipment Qualification San Onofre Nuclear Generating Station TER Resolution Stat us Unit 1 Page 8 Component Type:

Transmitters:

Flow/Level/Pressure/Teniperature (Cont'd.)

SCE SONGS-1 Equipment N.RC/IER Item #

ID Number Description Category Deficiencies Response/Resolution 3(30)

PT-432 Foxboro m/n E11GM IlA Documentation not adequate; Qualifiable for all parameters Similarity; Aging; Qualified except radiation.

Radiation Life/Replacement Schedule; qualification is being evaluated.

Aging Program; Duration Prof le Envelope; Test equence 1(25)

FT-460,461,462 Foxboro m/n E11DM H1A Documentation not adequate; Additional evaluation to addr Similarity; Aging Qualified deficiencies based on vendor Life/Replacement schedule; testing is being performed.

Aging Program; Duration Prof le Envelope; Test equence 13(23)

FT-500,501 Foxboro m/n E13DM IIA Documentation not adequate; Additional evaluation to address Similarity; Aging; Qualified deficiencies based on vendor type Life/Replacement Schedule; testing is being performed.

Aging Program; Duration; Profile Envelope; Test Sequence 25(20)

FT-504 Foxboro m/n E13DM HA Documentation not adequate; Additional evaluation to address Similarity; Aging; Qualified deficiencies based on vendor type Life/Replacement Schedule; testi.ng is being performed.

Aging Program 27(33)

PT-501,502,503 Foxboro m/n E11GM IIA Documentation not adequate; Additional evaluation to address Similarity; Aging; Qualified deficiencies based on vendor type Life/Replacement Schedule; testing is being performed.

Aging Program 80(32)

PT-425 Foxboro m/n E13GM IIA Documentation not adequate; Additional evaluation to address Similarity; Aging; Qualified deficiencies based on vendor type Life/Replacement Schedule; testing is being performed.

Aging Program; Duration; Profile Envelope; Test Sequence 91(24)

FT-602 Foxboro m/n E130M IIIB NA Not in Scope (cold shutdown equipment).

0755g / 12-09-83

Southern California Edison Environmental Equipment Qualification San Onofre Nuclear Generating Station TER Resolution Status Unit 1 Page 9 Component Type:

Transmitters:

Flow/Level/Pressure/Temperature (Cont'd.)

SCE SONGS-1 Equipment NRC/TER Item #

ID Number Description Category Deficiencies Response/Resolution 14(27)

LC-951 Gems Corp. m/n LS800 IB Qualification Pending New sump level monitoring equip Modification ment has been istalled. Documen tation is being prepared as part of TMI modification program.

fl7rrn i

nn o,)

Southern California Edison Environmental Equipment Qualification San Onofre Nuclear Generating Station TER Resolution Status Unit 1 Page 2 Component Type:

Level Switches SCE SONGS-1 Equipment NRC/TER Item #

ID Number Description Category Deficiencies Response/Resolution 17(26)

LS-73 Magnetrol IB Qualification Pending New sump level monitoring equip m/n A153FVPKTDM Modification ment has been installed. Documen tation is being prepared as part of TMI modification program.

0755g / 12-09-83

Southern California Edison Environmental Equipment Qualification San Onofre Nuclear Generating Station TER Resolution Status Unit I Page 11 Component Type:

Electrical Penetrations SCE SONGS-1 Equipment NRC/TER Item _

ID Number Description Category Deficiencies Response/Resolution 72(44)

Penetrations Amphenol IIA Documentation not adequate; Qualifiable. Documentation based Aging; Qualified Life/

on vendor type testing will be Replacement Schedule; performed.

Profile Envelope; Spray p

71(45)

Penetrations Conax IA NA Qualified.

70(43)

Penetrations Viking IIA Documentation not adequate; Additional evaluation to assess Profile Envelope; Steam; material capability and circuit Spray; Radiation applications will be performed.

0755g / 12-09-83

Southern California Edison Environmental Equipment Qualification San Onofre Nuclear Generating Station TER Resolution Status Unit I Page 12 Component Type:

Electric Motors SCE SONGS-1 Equipment NRC/TER Item #

ID Number Description Category Deficiencies Response/Resolution 44(52)

CV-525,527 Boston Gear m/n ADR IA Documentation not adequate Will be replaced as part of Efcomatic valve modification.

45(51)

CV-526,528 Boston Gear m/n ADR IIA Documentation not adequate Will be replaced as part of 49(51)

CV-515,516 Efcomatic valve modification.

11(47)

G-45A,B Chempump IIA Documentation not adequate Qualified by analysis for int n

m/n GPS-60L-46H-3T operation. Additional evaluatle to assess long-term qualification will be performed.

21(48)

G-27A,B Westinghouse m/n AALG IIC Aging; Qualified Life/

Qualified.

Documentation is in Replacement Schedule; progress.

Aging Program 5(49)

G-3A,B Westinghouse Type CS IIA Documentation not adequate Preliminary evaluation indicates steam is the only outstanding item. Additional evaluation to resolve this concern will be performed.

16(46)

G-8A,B Westinghouse CSP motor IV Documentation not provided Preliminary evaluation indicates m/n 65F15619 steam is the only outstanding item. Additional evaluation to resolve this concern will be performed.

62(50)

G-10 Westinghouse IIA Documentation not adequate Preliminary evaluation indicates steam is the onl outstanding item. Additional evaluation to resolve this concern will be performed.

0755g / 12-09-83

Southern California Edison Environmental Equipment Qualification San Onofre Nuclear Generating Station TER Resolution Status Unit 1 Page 1 Component Type:

Electrical Cables/Splices SCE SONGS-1 Equipment NRC/TER Item #

ID Number Description Category Deficiencies Response/Resolution 65(59)

Cable General Electric IIA Documentation not adequate; Qualifiable. Documentation based m/n Vulkene Similarity Qualified Life/

on vendor type testing is being Replacemeni Schedule performed.

66(53)

Cable Gene1 Eletric IIA Douention ota e

  • ualif able. Do um tat on based mnn I-E Neoprene arv A 17id n ven or ype es ng s be ng u

Aiem c e

  • ge per ormed.

gng Program; mergench 67(54)

Cable Rvehemr l

IA NA Qualified.

68(56)

Cable Rockbestos IA NA Qualified.

m/n Firewall III & SIS 69(55)

Cable Various IV Documentation not-provided Previous qualification evaluation is being reviewed against new environmental profi es.

Cables previously qua ified for contain ment use are still qualified. For other cables, the materials of construction and circuit require ments are being evaluated to establish qual1fication.

73(39)

Cable Splices Raychem m/n Thermofit IA NA Qualified.

0755g / 12-09-83

out er Calif rnia Ediso

.nvi onmn t ment Qua1i1fi.ation Ut yo re Nuc ear Generating Station

.e.sot on utat Component Type:

Position Switch 44(35)

N I iUer g'P Ion a___ry Deficiencies Response/Resolution 44(35)

CV-525,527 n

NA 702E1 IA Documentation not adequate ye mi t n.

nm tt A 702E1 1A.

Documentation not adequate m i c

edma1 ttn.

0755g / 12-09-83

Southern California Edison Environmental Equipment Qualification San Onofre Nuclear Generating Station TER Resolution Status Unit 1 Page 3 Component Type:

Limit Switches SCE SONGS-1 Equipment NRC/TER Item ID Number Description Category Deficiencies Response/Resolution 78(37)

PORV & Block NAMCo IIC Qualified Life/Replacement Qualified. Additional evaluation Valve m/n EA180-11302 & -12302 Schedule of qualified life/replacement schedule will be performed.

0 0755g / 12-09-83

Southern California Edison Environmental Equipment Qualifilatior San Onofre Nuclear Generating Station TER Resolution Status Unit 1 Page 4 Component Type:

Terminal Blocks SCE SONGS-1 Equipment NRC/TER Item #

ID Number Description Category Deficiencies Response/Resolution 75(40)

Terminal Block Various IA NA Replaced with qualified Raychem Thermofit Splices [see SCE let ters dated 4/28/81 and 5/18/81].

0 07550j / 12-09-83

Southern California Edison Environmental Equipment QualificNtion San Onofre Nuclear Generating Station TER Resolution StaLus Unit 1 Page 5 Component Type:

RTD SCE SONGS-1 Equipment NRC/TER Item #

ID Number Description Category Deficiencies Response/Resolution 61(38)

TE-606 Foxboro m/n DB-13V-26W IIA Documentation not adequate Evaluating modification of lead wires to establish qualification.

Also evaluating safety function of this component to see if required.

79(41)

TE 400thru Weed m/n 2004 IB Qualfication pending ReD1aced withnw wqualifidWe

-2 AB,C 0oifcation RTs Documna lni en oared as par o T l modi icat program.

0755g / 12-09-83

Southern California Edison Environmental Eauipment Qualif Xation San Onofre Nuclear Generating Station TER Resolution Status Unit 1 Page 6 Component Type:

Radiation Detector SCE SONGS-1 Equipment NRC/TER Item #[ ID Number Description

£jmgory Deficiencies Response(Resolutlion 87(42)

R-1232 TracerLab m/n AX-22 I

Qualification Pending Qualified General ALomic radia-Modification tion monitors have been installed.

Documentation is being prepared as part of TMI modification program.

0 0755g / 12-09-83

Southern California Edison Environmental Equipment Qualific tion San Onofre Nuclear Generating Station TER Resolution Status Unit 1 Page 19 Component Type:

Valve Positioner SCE SONGS-1 Equipment NRC/TER Item ID Number Description Category Deficiencies Response/Resolution 19(57)

FCV-11150,E,F Honeywell m/n IS HE-1 IB.

Qualification pending Replaced with qualified equip modification ment. Documentation and develop.

ment of maintenance intervals has been prepared.

6(58)

HV-851 thru Teledyne IV Documentation not provided Previous qualification is being

-854 A,B m/n 02112-002-5210 and reviewed to incorporate new

-003-5210 environmental profiles.

0755g / 12-09-83