Summary of 841026 Meeting W/Util in Bethesda,Md Re Environ Qualification of Electrical Equipment Audit Held on 841002-04.List of Attendees Encl
ML13324A486
Person / Time
Site: San Onofre 
Issue date: 11/08/1984
From: Mckenna E
Office of Nuclear Reactor Regulation
To:
Office of Nuclear Reactor Regulation
References
LSO5-84-11-006, LSO5-84-11-6, TAC-42516, NUDOCS 8411120242
Download: ML13324A486 (3)


Text

o UNITED STATES j ~NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 November 8, 1984 Docket No. 50-206 LSO5-84-11-006 LICENSEE:

SOUTHERN CALIFORNIA EDISON COMPANY FACILITY:

SAN ONOFRE NUCLEAR GENERATING STATION, UNIT NO. 1

SUBJECT:

OCTOBER 26, 1984 MEETING ON ENVIRONMENTAL QUALIFICATION OF ELECTRICAL EQUIPMENT On October 26, 1984, members of the NRC staff and consultants met with representatives of Southern California Edison Company, licensee-for San Onofre Unit 1, in Bethesda, Maryland. A list of attendees is enclosed.

The meeting was a followup to the electrical equipment qualification audit held on October 2 through 4, 1984; the results of this audit were trans mitted by separate correspondence.

As a result of the audit, the staff identified actions for the licensee to undertake regarding the need for the licensee to provide justifications for continued operation (JCOs) for equipment which will not be fully qualified prior to plant return to service.

Specifically, the staff requested during the audit that the JCOs be updated to specifically address the provisions of 10 CFR 50.49(i).

At the meeting, the licensee presented revised JCOs which factored in the staff audit findings.

In particular, the two major concerns identified in the audit, Viking penetrations and cables listed as "various", were discussed.

The licensee has prepared revised JCOs for the Viking penetration which consider the functions served by the penetrations, test reports from similar penetrations and the time period in which affected circuits are required to act.

Since the audit, the licensee has completed docufnentation searches to match cable manufacturers to cabling used in safety-related applications. Therefore, the category previously listed as "various" has-been eliminated. JCOs are in place for each of the cable types. Based on the information discussed at the meeting, the staff is satisfied that the problems identified during the audit are being resolved. The licensee has agreed to submit revised JCOs in the near future.

Eileen -1cKenna, Project Manager Operating Reactors Branch #5 Division of Licensing

cc Charles R. Kocher, Assistant Mr. Kenneth P. Baskin, Vice President General Counsel Nuclear Engineering James Deoletto, Esquire Licensing and Safety Department Southern California Edison Company Southern California Edison Company Post Office Box 800 2244 Walnut Grove Avenue Rosemead, California 91770 Post Office Box 800 Rosemead, California 91770 David R. Pigott Orrick, Herrington & Sutcliffe 600 Montogmery Street San Francisco, California 94111 Dr. Lou Bernath San Diego Gas & Electric Company P. 0. Box 1831 San Diego, California 92112 Resident Inspector/San Onofre NPS c/o U.S. NRC P. 0. Box 4329 San Clemente, California 92672 Mayor City of San Clemente San Clemente, California 92672 Chairman Board of Supervisors County of San Diego San Diego, California 92101 Director Energy Facilities Siting Division Energy Resources Conservation &

Development Commission 1516 -

9th Street Sacramento, CA 95814 U.S. Environmental Protection Agency Region IX Office ATTN:

Regional Radiation Representative 215 Freemont Street San Francisco, California 94105 John B. Martin, Regional Administrator Nuclear Reculatory Commission, Region V 1450 Maria Lane Walnut Creek, California 94596

NRC/SCE MEETING OCTOBER 26, 1984 Name Affil itiation Eileen McKenna NRC/DL Paul Shemanski N RC/DE Max Yost INEL Richard Borgen INEL Jack Rainsberry SCE Tony Llorens SCE Bernie Carlisle SCE Vince Franceschi IMPELL