ML13238A234

From kanterella
Jump to navigation Jump to search

Requests for Additional Information for the Review of the Grand Gulf Nuclear Station, License Renewal Application (TAC No. ME7493) - Set 49
ML13238A234
Person / Time
Site: Grand Gulf 
Issue date: 09/12/2013
From: Daily J
License Renewal Projects Branch 1
To: Kevin Mulligan
Entergy Operations
Daily J 415-3873
References
TAC ME7493
Download: ML13238A234 (5)


Text

Mr. Kevin Mulligan Vice President, Site Entergy Operations, Inc.

P.O. Box 756 Port Gibson, MS 39150 UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 September 12, 2013

SUBJECT:

REQUESTS FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE GRAND GULF NUCLEAR STATION, LICENSE RENEWAL APPLICATION (TAC NO. ME7493)- SET 49.

Dear Mr. Mulligan:

By letter dated October 28, 2011, Entergy Operations, Inc., submitted an application pursuant to Title 10 of the Code of Federal Regulations (CFR) Part 54, to renew the operating license, NPF-29, for Grand Gulf Nuclear Station, Unit 1, for review by the U.S. Nuclear Regulatory Commission (NRC) staff. The staff is reviewing the information contained in the license renewal application and has identified, in the enclosure, areas where additional information is needed to complete the review.

These requests for additional information (RAis), outlined in the Enclosure, were discussed with Ted Ivy, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me at 301-415-3873 or by e-mail at john.daily@nrc.gov.

Docket Nos. 50-416

Enclosure:

Requests for Additional Information cc w/encl: Listserv Sincerely, Je~

John Daily, Senior Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation

ML13238A234 OFFICE LA:RPB1 :DLR PM:RPB1 :DLR BC:RPB1 :DLR PM: RPB1 :DLR NAME YEdmonds JDaily Y Diaz-Sanabria J Daily DATE 8/27/2013 9/9/2013 9/10/2013 9/12/2013

RAI 3.0.5-1 c

Background

GRAND GULF NUCLEAR STATION LICENSE RENEWAL APPLICATION REQUESTS FOR ADDITIONAL INFORMATION In response to RAI 3.0.5-1 b, the applicant stated that its programmatic activities for identifying and reporting age-related operating experience are consistent with the guidance in License Renewal Interim Staff Guidance, LR-ISG-2011-05, "Ongoing Review of Operating Experience."

(a)

The applicant stated that it will use the corrective action program (CAP) codes "CA" and "EO" to identify operating experience concerning age-related degradation applicable to the plant. LR-ISG-2011-05 states that code(s) should be used specifically for the identification of age-related items. However, per the definitions provided in response to RAI 3.0.5-1 a, the codes "CA" and "EO" are used to identify trends and equipment problems involving aging or "other issues." The intended application of these codes is unclear because they may be used to identify non-age-related items along with age-related items.

(b)

The applicant stated that it reports its own age-related operating experience to the industry based on the guidelines in INPO 12-009 "INPO Consolidated Event System."

LR-ISG-2011-05 states that specific guidelines should be established for reporting plant-specific operating experience on age-related degradation and aging management.

However, the operating experience reporting criteria listed in IN PO 12-009, Chapter 2, either are not specific to aging or only cover limited situations involving aging. As such, these criteria are not comprehensive and do not cover all age-related operating experience that may warrant reporting.

Request Address these items for demonstrating consistency with the guidance in LR-ISG-2011-05:

(a) Provide revised definitions for codes "CA" and "EO" to clarify that their intended application is for the identification of age-related items, or describe other code(s) that will be used specifically for this purpose.

(b) Describe specific guidelines for identifying circumstances in which plant-specific operating experience involving age-related degradation and aging management will be reported to the industry.

Alternatively, justify why the operating experience review activities provide for the adequate consideration of operating experience involving age-related degradation and aging management to maintain the effectiveness of the aging management programs (AMPs) and activities.

ENCLOSURE

Identify any necessary enhancements to existing activities based on the response to this request. Provide the schedule for implementing these enhancements and a justification if implementation is later than the date when the renewed operating license is scheduled to be issued, if approved.

RAI 3.0.5-1 d

Background

LRA Section A.0.1, as amended most recently by letter dated April 15, 2013, provides the UFSAR supplement summary description of the ongoing operating experience review activities.

The applicant's response to RAI 3.0.5-1 a (in a letter dated November 29, 2012), states that the operating experience review activities include:

review of revisions to NUREG-1801, "Generic Aging Lessons Learned (GALL) Report,"

as a source of industry operating experience; and evaluation of age-related operating experience items based on consideration of affected plant systems, structures, and components; materials; environments; aging effects, aging mechanisms; AMPs; and the activities, criteria, and evaluations integral to the elements of the AMPs.

The summary description in LRA Section A.0.1 does not address these activities.

Request Revise LRA Section A.0.1 to include a description of the activities identified above. Otherwise, provide a justification for not including such a description in the UFSAR supplement.

SUBJECT:

REQUESTS FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE GRAND GULF NUCLEAR STATION, LICENSE RENEWAL APPLICATION (TAC NO. ME7493)

-SET 49.

DISTRIBUTION:

HARD COPY:

DLRRF E-MAIL:

PUBLIC RidsNrrDir Resource RidsNrrDirRpb1 Resource RidsNrrDirRpb2 Resource RidsNrrDirRerb Resource RidsNrrDirRarb Resource RidsNrrDirRasb Resource RidsNrrDirRapb Resource RidsNrrDirRpob Resource john.daily@nrc.gov emmanuel.sayoc@nrc.gov david.drucker@nrc.gov david.wrona@nrc.gov melanie. wong@nrc.gov yoira.diaz-sanabria@nrc.gov dennis.morey@nrc.gov rich.smith@nrc.gov, blake. rice@nrc.gov greg.pick@nrc.gov david.mcintyre@nrc.gov