MONTHYEARGNRO-2011/00064, License Amendment Request to Revise Technical Specification 2.1.1.22011-10-28028 October 2011 License Amendment Request to Revise Technical Specification 2.1.1.2 Project stage: Request ML11350A0532012-01-0404 January 2012 Plan for the Scoping and Screening Regulatory Audit Regarding the Grand Gulf Nuclear Station, Unit 1 License Renewal Application Review Project stage: Other ML12009A1052012-01-18018 January 2012 Plan for the Aging Management Program Regulatory Audit Regarding the Grand Gulf Nuclear Station, Unit 1, License Renewal Application Review Project stage: Other ML12067A2352012-04-0303 April 2012 Requests for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application Project stage: RAI ML12068A2332012-04-0404 April 2012 Requests for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application Project stage: RAI ML12080A1912012-04-11011 April 2012 Request for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application Grand Gulf LRA RAI Set 3 Project stage: RAI ML12074A0082012-04-12012 April 2012 Requests for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application Project stage: RAI ML12076A0142012-04-16016 April 2012 Request for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application (TAC No. ME7493) Grand Gulf LRA Draft RAI Set 5 Project stage: Draft RAI ML12076A0092012-04-17017 April 2012 Requests for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal (TAC ME7493) Grand Gulf LRA Draft RAI Set 6 Project stage: Draft RAI GNRO-2012/00024, Supplemental Information Extended Power Uprate2012-04-18018 April 2012 Supplemental Information Extended Power Uprate Project stage: Request ML12087A0012012-04-18018 April 2012 Requests for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application (TAC ME7493)Grand Gulf LRA RAI Set 07 Project stage: RAI ML12094A0092012-04-25025 April 2012 Requests for Additional Information for the Review of the Grand Gulf Nulcear Station Licesne Renewal Application Project stage: RAI ML12101A3602012-04-26026 April 2012 Request for Additional Information for the Review of Th Grand Gulf Nuclear Station License Renewal Application (TAC No. ME7493) Grand Gulf LRA RAI Set 09 Project stage: RAI ML12104A2192012-04-30030 April 2012 Request for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application (TAC No. ME7493)LRA RAI Set 10 Project stage: RAI GNRO-2012/00029, Response to Request for Additional Information (RAI) Regarding the License Renewal Application2012-05-0101 May 2012 Response to Request for Additional Information (RAI) Regarding the License Renewal Application Project stage: Response to RAI ML12109A2132012-05-0303 May 2012 Requests for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application (TAC No. ME7493) Grand Gulf LRA RAI Set 11 Project stage: RAI ML12115A0902012-05-0909 May 2012 Requests for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application Project stage: RAI ML12115A2762012-05-0909 May 2012 Request for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application (TAC No. ME7493)Grand Gulf LRA RAI Set 13 Project stage: RAI GNRO-2012/00036, Response to Request for Additional Information (RAI) Dated April 12, 20122012-05-0909 May 2012 Response to Request for Additional Information (RAI) Dated April 12, 2012 Project stage: Response to RAI ML12117A3832012-05-14014 May 2012 Requests for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application Project stage: RAI ML12118A5392012-05-15015 May 2012 Requests for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application Project stage: RAI ML12125A3732012-05-24024 May 2012 Requests for Additional Information for the Review of the Grant Gulf Nuclear Station License Renewal Application (TAC No. ME7493)Grand Gulf LRA RAI Set 17 Project stage: RAI GNRO-2012/00033, Response to Request for Additional Information (RAI) Dated April 25, 20122012-05-25025 May 2012 Response to Request for Additional Information (RAI) Dated April 25, 2012 Project stage: Response to RAI ML12139A0552012-05-29029 May 2012 LRA RAI Set 19 Project stage: RAI ML12137A2962012-06-0505 June 2012 Request for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application (TAC No. ME7493) Grand Gulf LRA RAI Set 18 Project stage: RAI GNRO-2012/00056, Response to Request for Additional Information (RAI) Set 13 Dated May 9, 20122012-06-0505 June 2012 Response to Request for Additional Information (RAI) Set 13 Dated May 9, 2012 Project stage: Response to RAI ML12137A2902012-06-0808 June 2012 Aging Management Programs Audit Report Regarding the Grand Gulf Nuclear Station, Unit 1 (TAC No. ME7493) Grand Gulf AMP Audit Report Cover Letter Project stage: Other ML12151A2652012-06-15015 June 2012 Request for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application (TAC No. ME7493) Grand Gulf LRA RAI Set 20 Project stage: RAI ML12165A3872012-06-20020 June 2012 Scoping and Screening Methodology Audit Report Regarding the Grand Gulf Nuclear Station, Unit 1, License Renewal Application Project stage: Other ML12151A3682012-06-20020 June 2012 Requests for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application Project stage: RAI ML12152A3452012-06-22022 June 2012 Request for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application (Tac No. ME7493) Project stage: RAI ML12152A3932012-06-22022 June 2012 Request for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application Project stage: RAI 05000416/LER-2012-004, Regarding Weld Defect Indication Found in Residual Heat Removal System to Reactor Pressure Vessel Boundary Nozzle2012-06-27027 June 2012 Regarding Weld Defect Indication Found in Residual Heat Removal System to Reactor Pressure Vessel Boundary Nozzle Project stage: Request ML12164A1742012-06-27027 June 2012 Request for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application (TAC No. ME7493) Grand Gulf LRA RAI Set 26 Project stage: RAI ML12157A0562012-06-27027 June 2012 Request for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application (TAC No. ME7493)Grand Gulf LRA RAI Set 24 Project stage: RAI ML12164A7262012-06-27027 June 2012 RAI for the Review of the Grand Gulf Nuclear Station License Renewal Application Project stage: RAI ML12179A1372012-07-17017 July 2012 Summary of Telephone Conference Call Between NRC and Entergy Operations, Inc., Concerning Requests for Additional Information Pertaining to Grand Gulf License Renewal Application Project stage: RAI ML12180A5412012-07-17017 July 2012 Summary of Telephone Conference Call Held on March 14, 2012, Between NRC and Entergy Operations, Inc., Concerning RAI Pertaining to the Grand Gulf Nuclear Station, LRA Project stage: RAI ML12188A7062012-07-17017 July 2012 Requests for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application Project stage: RAI ML12188A5162012-07-23023 July 2012 Requests for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application Project stage: RAI GNRO-2012/00080, Response to Request for Additional Information (RAI) Set 24 Dated June 27, 20122012-07-25025 July 2012 Response to Request for Additional Information (RAI) Set 24 Dated June 27, 2012 Project stage: Response to RAI ML12200A1382012-07-27027 July 2012 Requests for Additional Information for the Review of the Grand Gulf Nuclear Station License Renewal Application Project stage: RAI ML12201B4762012-07-27027 July 2012 LRA RAI Set 30 Project stage: RAI ML12180A4672012-07-31031 July 2012 LRA RAI Telecon 2012-04-03 Project stage: RAI ML12191A1872012-07-31031 July 2012 LRA RAI Telecon 2012-04-13 Project stage: RAI ML12208A2672012-08-0707 August 2012 RAI for the Review of the Grand Gulf Nuclear Station License Renewal Application Project stage: RAI ML12193A0712012-08-15015 August 2012 Summary of Telephone Conference Call Held on 5/15/12 Between the U.S. Nuclear Regulatory Commission and Entergy Operations, Inc., Concerning Requests for Additional Information Pertaining to the Grand Gulf Nuclear Station, LRA Project stage: RAI GNRO-2012/00092, Response to Requests for Additional Information (RAI) Set 28 Dated July 23, 20122012-08-15015 August 2012 Response to Requests for Additional Information (RAI) Set 28 Dated July 23, 2012 Project stage: Response to RAI ML12201B5042012-08-15015 August 2012 Summary of Telephone Conference Call Held on 5/23/12 Between the U.S. Nuclear Regulatory Commission and Entergy Operations, Inc., Concerning the RAIs Pertaining to the Grand Gulf Nuclear Station License Renewal Application Project stage: RAI ML12202A2142012-08-15015 August 2012 5/30/12 Summary of Telephone Conference Call Held Between the U.S. Nuclear Regulatory Commission and Entergy Operations, Inc., Concerning Requests for Additional Information Pertaining to the Grand Gulf Nuclear Station, LRA Project stage: RAI 2012-05-24
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555*0001 August 7, 2012 Mr. Michael Perito Vice President, Site Entergy Operations, Inc.
P.O. Box 756 Port Gibson, MS 39150
SUBJECT:
REQUESTS FOR ADDITIONAL INFORMATION FOR THE REVIEW OF THE GRAND GULF NUCLEAR STATION LICENSE RENEWAL APPLICATION (TAC NO. ME7493)
Dear Mr. Perito:
By letter dated October 28, 2011, Entergy Operations, Inc., submitted an application pursuant to Title 10 of the Code of Federal Regulations Part 54, to renew the operating license for Grand Gulf Nuclear Station, Unit 1 (GGNS) for review by the U.S. Nuclear Regulatory Commission (NRC or the staff). The staff is reviewing the information contained in the license renewal application and has identified, in the enclosure, areas where additional information is needed to complete the review.
These requests for additional information were discussed with Jeff Seiter, and a mutually agreeable date for the response is within 30 days from the date of this letter. If you have any questions, please contact me at 301-415-1045 or bye-mail at nathaniel.ferrer@nrc.gov.
Jx
.N{ }rr Nathaniel rrer, Pr 'ect Ma M-Projects Branch 1 Division of License R new Office of Nuclear Rea Docket No. 50-416
Enclosure:
As stated cc w/encl: Listserv*
GRAND GULF NUCLEAR STATION LICENSE RENEWAL APPLICATION REQUESTS FOR ADDITIONAL INFORMATION SET 31 RAI4.3-5a Background. In the response to request for additional information (RAI) 4.3-5 dated June 21, 2012, the applicant stated that the design speCifications of expansion joints identified a conservative number of cycles at a given amount of expansion so that simplified analyses could be performed. The applicant also stated that the typical analysis shows the expansion joint is qualified for many more cycles than was specified with these simplified bounding assumptions and Entergy Nuclear, Inc. (Entergy) completed a review of these analyses to verify the expansion joints are adequate for 60 years. The applicant also explained seismically qualified expansion joints have cycle specifications for seismic events and expansion joints inside primary containment include cycles due safety relief valve (SRV) lifts.
The staff noted the concerns identified in RAI4.3-5 were related to license renewal application (LRA) Section 4.3.2.2, which discusses metal fatigue of non-Class 1 non-piping components. The applicant did not provide the number of cycles that the design specifications identified for non-Class 1 expansion joints. The applicant also did not provide the number of cycles for earthquakes and SRV actuations that are assumed in the design of its non-Class 1 expansion joints. Therefore, the staff cannot verify the adequacy of the disposition of the time limited aging analysis (TLAA) in accordance with Title 10 of the Code of Federal Regulations (10 CFR) 54.21 (c)(1)(i).
Reguest.
- a. Identify all the transients and associated number of cycles that were considered as an input to the fatigue analyses of the non-Class 1 expansion joints discussed in LRA Section 4.3.2.2. In addition, identify all the non-Class 1 expansion joints that are inside primary containment.
- b. Describe the details of the review that was completed for these expansion joint fatigue analyses in order to verify the components are adequate for 60-years of operation.
Justify that this review and evaluation demonstrates that the number of cycles originally analyzed as part of the expansion joint design will not be exceeded after 60-years of operation, in accordance with 10 CFR 54.21(c)(1)(i).
- c. Justify the statement, in response to RAI 4.3-5, that the allowable numbers of cycles for the other transients (Le., transients used in fatigue analyses other than SRV and seismic) are well beyond reasonably postulated numbers of the transients, making it unnecessary to monitor these transients.
- d. Justify the statement, in response to RAI 4.3-5, that the typical analysis shows the expansion joint is qualified for many more cycles than was specified with the simplified bounding assumptions as it relates to transients used in the fatigue analyses, except for SRV and seismic transients.
ENCLOSURE
- 2 RAI4.3-9a Background. In the response to RAI 4.3-9 dated June 21, 2012, revised LRA Section A.2.2.3 states that industry-accepted techniques will be used for consideration of the effects on fatigue of the reactor water environment (environmentally assisted fatigue - EAF), including techniques for incorporating the impact of dissolved oxygen concentration into the calculation of fatigue environmental correction factors.
Issue. The staff noted that it is possible these industry-accepted techniques may not or will not be approved for use by the staff. Furthermore, the staff noted that the concern identified in RAI 4.3-9 specifically addressed the use of a time-weight percentage for hydrogen water chemistry/normal water chemistry (HWC/NWC) in the formulation of Fen values would underestimate the environmentally-adjusted cumulative usage factors (CUFs). This underestimate in the CUFen may potentially be non-conservative for carbon steel/low alloy steel components. The applicant has not explained how the use of unspecified industry-accepted techniques will resolve this potential non-conservatism.
Request.
- a. Revise LRA Section A.2.2.3 to indicate that future calculation of Fen values will incorporate available transient cycle occurrence data during operating times in NWC and HWC instead of using a time-weight percentage for NWC and HWC operation.
- b. In lieu of revising LRA Section A.2.2.3, justify the appropriateness of relying upon the use of industry-accepted techniques that are not clearly specified and have not been approved by the staff for incorporating the impact of dissolved oxygen concentration into the calculation of fatigue environmental correction factors.
RAI 8.1.34-2a Background. LRA Section B.1.34 states that the applicant has not experienced cracking in its ASME Code Class 1 small bore piping. However, no specific information was provided regarding the search and the source of its operating experience. The staff issued RAI B.1.34-2 in a letter dated April18, 2012. The RAI requested that the applicant to identify the specific sources of information reviewed and describe the process or methodology used to find potential instances of cracking in Class 1 small-bore piping.
The applicant provided its response to RAI B.1.34-2 in a letter dated May 18, 2012. In its response, the applicant stated that the specific sources of information reviewed were the paperless condition reporting system (PCRS), the NRC Licensee Event Reports (LER) database submitted from Entergy nuclear facilities and interviews with its plant staff. It further stated that its PCRS search, "included a review of ten years of operating experience contained in the PCRS."
Issue. The staff noted that although the plant has been in operation for approximately 27 years, the applicant's search of its plant-specific operating experience using its database, PCRS, was limited to 10 years. In addition, supplementing the PCRS database review with information obtained from the NRC LER database the information may not be sufficient or complete, since the NRC LER database, which only includes events that meet reporting criteria outlined in 10 CFR 50.72 and 50.73, may not be all inclusive. The staff also determined that interviews of
- 3 plant personnel, while potentially providing additional context for previously documented information, does not constitute an established repository of operating experience information.
Request. The staff requests that the applicant provide a technical basis for limiting the review of plant-specific operating experience contained in the PCRS, or other plant databases, to the previous 10 years of operation for the One-Time Inspection - Small-Bore Piping Program.
ENCLOSURE
'.. ML12208A267 OFFICE LA:RPB1 :DLR PM:RPB1 :DLR BC:RPB1 :DLR PM: RPB1 :DLR NAME IKing NFerrer DMorey NFerrer DATE 8/2/12 8/3/12 8/7/12 8/7/12