Rev.

00802 OFFSITE DOSE CALCULATION MANUAL Page 201 of 318 SPECIAL EXCEPTIONS AND ASSUMPTIONS FOR CALCULATION OF DOSES AND DOSE RATES 1.

Camp Conoy a)

Location (1)

Camp Conoy is located within the SITE BOUNDARY.

(2)

Camp Conoy is located in the SE sector.

(3)

Camp Conoy is approximately 3000 feet from the plant.

b)

Occupancy (1)

Camp Conoy is frequently visited by MEMBERS OF THE PUBLIC.

(2)

Maximum occupancy for MEMBERS OF THE PUBLIC at Camp Conoy is restricted to approximately 3380 hours0.0391 days <br />0.939 hours <br />0.00559 weeks <br />0.00129 months <br /> per year.

c)

Meteorology (1)

The highest historical. annual average x/Q for Camp Conoy is 2.40E-6 seconds per cubic meter.1 d)

Dose calculation assumptions (1)

Based on sections (b) and (c) above, any actual exposure to a MEMBER OF THE PUBLIC at Camp Conoy will be less than the calculated exposure for a MEMBER OF THE PUBLIC at the SITE BOUNDARY.1 (2)

No special considerations are required for addressing potential exposure at Camp Conoy.

2.

Visitor's Center a)

Location (1)

The Visitor's Center is located within the SITE BOUNDARY.

(2)

The Visitor's Center is located in the WNW sector.

(3)

The Visitor's Center is approximately 1000 feet from the plant.

b)

Occupancy (1)

The Visitor's Center is frequently visited by MEMBERS OF THE PUBLIC.

(2)

Maximum occupancy for MEMBERS OF THE PUBLIC at The Visitor's Center is restricted to daylight hours.

1 See CP-607, Revision 2 page 24.

SDATRev.

00802 OFFSITE DOSE CALCULATION MANUAL Page 202 of 318 C)

Meteorology (1)

The highest historical annual average x/Q for the Visitor's Center is 8.68E-6 seconds per cubic meter.1 (2)

The wind frequency for the WNW sector, based on 1983 meteorological data, is four percent (4%).1 d)

Dose calculation assumptions (1)

"Using a conservative basis of 10% wind frequency, and individual visiting the center for 330 hour0.00382 days <br />0.0917 hours <br />5.456349e-4 weeks <br />1.25565e-4 months <br />s/year during the periods of worst case meteorological conditions would be most highly exposed."1 (2)

The dose calculated for the controlling SITE BOUNDARY is more conservative by a factor of 7.1 (3)

Based on sections (b) and (c) above, any actual exposure to a MEMBER OF THE PUBLIC at The Visitor's Center will be less than the calculated exposure for a MEMBER OF THE PUBLIC at the SITE BOUNDARY.

(4)

No special considerations are required for addressing potential exposure at The Visitor's Center.

1 See CP-607, Revision 2 page 24.

(1St DLAL Rev.

00802 E DOSE CALCULATION ML Page 203 of 318 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM1 1.

Introduction a) 10 CFR 50, Appendix I, Section IV.B.2 requires licensees to establish an environmental surveillance and monitoring program for the purpose of evaluating the relationship between quantities of radioactive material released in effluents and resultant radiation doses to individuals.

b)

Radiological environmental controls have been established to implement the requirements of 10 CFR 50, Appendix I, Section IV.B.2.

c)

These radiological environmental controls are described below.

2.

Controls on the Radiological Environmental Monitoring Program (REMP) a)

The REMP shall consist of environmental sample locations, analysis parameters, analysis frequencies, detection limits, and ACTION levels all of which conform to the requirements of Control 3.12.1. (See Attachment 13, 14, 15, 16, and 17).

b)

The REMP shall maintain a map showing sample locations near the SITE BOUNDARY in accordance with Control 3.12.1. (See Attachment 18).

c)

The REMP shall maintain a map showing sample locations within a 8 km. radius of the plant in accordance with Technical Specification 5.6.2. (See Attachment 19).

3.

Surveillance Requirements a)

Surveillances for direct radiation (1)

Direct radiation dosimetry shall be collected from locations DR1-DR23 listed on Attachment 13.

(2)

In the event any of the monitoring stations, DR1-DR23, described on 3 become unavailable, establish new monitoring stations (with new dosimetry) as described below:

(a)

In lieu of any location DR1-DR9 described on Attachment 13, establish a new monitoring station in the same meteorological sector in the general area of the SITE BOUNDARY.

(b)

In lieu of any location DR10-DR18 described on Attachment 13, establish a new monitoring station in the same meteorological sector in the 6-8 km range from the site.

This portion of the environmental monitoring program is designed to monitor the environment surrounding the CCNPP. A separate environmental monitoring program designed to monitor the environment surrounding the Independent Spent Fuel Storage Installation is described elsewhere in the ODCM.

FF DO'SE I N...

AL Rev.

00802 OFFSITE DOSE CALCULATION MANUAL Page 204 of 318 (c)

In lieu of any location.DR19-DR23 described on Attachment 13, establish a new monitoring station in either a special interest area (e.g., population center, nearby residence, school) or a control station whichever is applicable.

(3)

In the event any dosimetry at an existing monitoring location DR1-DR23 becomes unavailable, place new dosimetry at the monitoring station.

(4)

Analyze the dosimeters at the frequencies and for the parameters identified on Attachment 14.

(5)

The sampling locations(s), excluding the control station location, having, the lowest calculated dose or dose commitment(s), via the same exposure pathway, may be deleted from the RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM after October 31 of the year in which the land use census was conducted in accordance with Control 3.12.2.b.

b)

Surveillances for airborne activity (1)

Radioiodine and particulate samples shall be collected from locations Al-A5 listed on Attachment 13.

(2)

In the event any of the monitoring stations, Al-A5, described on Attachment 13 become unavailable, establish new monitoring station(s) (fitted with new radioiodine and particulate samplers) as described below:

(a)

In lieu of any location A1-A3 described on Attachment 13, establish a new monitoring station in the general area of the SITE BOUNDARY, such that the three monitoring stations are located in the meteorological sectors with the three highest calculated annual average ground level D/Q.

(b)

In lieu location A4.described on Attachment 13, establish a new monitoring station near a community having the highest calculated annual average ground level D/Q.

(c)

In lieu of location A5 described on Attachment 13 establish a new "control" location 15 to 30 kilometers from the plant in the least prevalent wind direction.

SDATRev.

00802 OFFSITE DOSE CALCULATION MANUAL Page 205 of 318 (3)

In the event any radioiodine cartridge or particulate filter becomes unavailable from an existing monitoring location Al-A5 described on Attachment 13, place new radioiodine cartridge or particulate filter in the air sampler at the monitoring station.

(4)

Analyze the samples at the frequencies and for the parameters identified on 5.

(5)

The sampling locations(s), excluding the control station location, having the lowest calculated dose or dose commitment(s), via the same exposure pathway, may be deleted from the RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM after October 31 of the year in which the land use census was conducted in accordance with Control 3 12.2.b.

c)

Surveillances of waterborne activity (1)

Water and sediment samples shall be collected from the locations Wal, Wa2, and Wbl listed on Attachment 13.

(2)

In the event any of the samples at Wal, Wa2, or Wbl are unavailable, collect substitute samples as described below:

(a)

In lieu of a liquid sample at Wal, collect a substitute sample of surface water from the intake area..

(b)

In lieu of a liquid sample at Wa2, collect a substitute sample of surface water from the discharge area.

(c)

In lieu of sample at Wbl, collect a substitute sample of sediment from a downstream shoreline with existing or potential recreational value.

(3)

Analyze the samples at the frequencies and for the parameters identified on 6.

(4)

The sampling locations(s), excluding the control station location, having the lowest calculated dose or dose commitment(s), via the same exposure pathway, may be deleted from the RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM after October 31 of the year in which the land use census was conducted in accordance with Control 3.12.2.b.

d)

Surveillances for ingestible activity (1)

Fish/invertebrate, milk, and food product samples shall be collected from the locations lal thru la6 and IbIl thru Ib9 listed on Attachment 13.

(2)

In the event any of the samples at lal thru la6 or Ibl thru Ib9 are unavailable, collect substitute samples as described below:

(a)

In lieu of samples at lal thru la3, collect substitute three commercially and/or recreationally important species (two fish species and one invertebrate species) from the vicinity of the plant discharge area.

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 206 of 318 (b)

In lieu of samples at la4 thru la6, collect three commercially and/or recreationally important species (two fish species and one invertebrate species) from an area not influenced by plant discharges.

(c)

In lieu of samples at Ibl thru Ib6, collect three kinds of broad leaf vegetation grown near the SITE BOUNDARY at two different locations of highest average ground level D/Q1.

(d)

In lieu of samples at Ib7 thru Ib9, collect one sample each of the similar broad leaf vegetation grown 15-30 km distant in the least prevalent wind direction.

(3)

Analyze the samples at the frequencies and for the parameters identified on 7.

(4)

The sampling locations(s), excluding the control station location, having the lowest calculated dose or dose commitment(s), via the same exposure pathway, may be deleted from the Radiological Environmental Monitoring Program after October 31 of the year in which the land use census was conducted in accordance with Control 3.12.2.b.

4.

Responsible Company Organizations a)

The CHEMISTRY SECTION, CCNPPI is responsible for ensuring performance of the surveillances listed above.

5.

Initiating conditions a)

Collect samples in accordance with the frequencies specified on Attachments 14, 15, 16, and 17.

b)

Analyze samples in accordance with the frequencies specified on Attachments 15, 16, and 17.

c)

Calculate the potential annual doses in accordance with the methodology outlined below if any of the following conditions are true:

(1) any of the above surveillance results reveal levels of environmental activity greater than the ACTION Levels specified on Attachments 15, 16, 17 (per Control Table 3.12-2)

(2) any radionuclides other than those in Attachments 15, 16, and 17 are detected, and the radionuclides are the result of plant effluents.

d)

The REMP Manager is responsible for notifying the General Supervisor--Chemistry, CCNPP, if any of the following conditions are true:

With fresh leafy vegetable samples unavailable from one or more of the sample locations listed on 3, perform corrective actions specified by Control 3.12.1.c.

DRev..

00802 OFFSITE DOSE CALCULATION MANUAL Page 207 of 318 (1) any of the above surveillance results reveal levels of environmental activity greater than the ACTION Levels specified on Attachments 15, 16 17 (per Control Table 3.12-2)

(2) any radionuclides other than thosein Attachments 15, 16, and 17 are detected, and the radionuclides are the result of plant effluents, and the potential annual doses due to the radionuclides are greater than the calendar year limits of Controls 3.11.1.2, 3.11.2.2, and 3.11.2.3.

6.

Calculation methodology a)

If the correct initiating conditions, as described above, are present, calculate potential annual doses for the pathway of interest in accordance with the methodologies contained in ODCM, or b) if methodologies other than those listed in the ODCM are used to calculate potential annual doses, such methodologies shall be documented in the AREOR in accordance with Control 3.12.1.b.

7.

Corrective ACTIONS a)

If a sample is unobtainable due to sampling equipment malfunction, then attempt to restore equipment to operable status before the end of the next sampling period, and document in the AREOR (per Control 4.12.1, Table 3:12-1, notation "a").

b)

If the RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM is not being conducted in accordance with Attachments 13, 14, 15, 16, or 17 document deviations in the AREOR (per Control 3.12.1.a).

c)

With fresh leafy vegetable samples unavailable from one or more of the sample locations listed on Attachment 13, establish a new monitoring location and document applicable information in the AREOR (per Control 3.12.1.c).

d)

When the analysis result for any parameter exceeds the ACTION Level listed on Attachments 15,16, or 17, submit a Special Report to the NRC (per Control 3.12. 1.b).

e)

When radionuclides other than those listed on Attachments 15, 16, and 17 are detected; and if those radionuclides are the result of plant effluents; and if the potential annual doses due'to the radionuclides are greater than the calendar year limits of Controls 3.11.1.2, 3.11.2.2, and 3.11.2.3; submit a Special Report in accordance with Control 3.12.1.b.

OFFSITE DOSE CALCULATION MANUAL Rev 00802 Page 208 of 318 LAND USE-CENSUS

1.

Introduction a) 10 CFR 50, Appendix I, Section IV.B.3 requires licensees to identify changes in the use of UNRESTRICTED AREAS in order to permit modifications in monitoring programs.

b)

Radiological environmental controls have been established to implement the requirements of 10 CFR 50, Appendix I, Section IV.B.3.

c)

These radiological environmental controls are described below.

2.

Controls on the Land Use Census a)

Identify the location of the nearest milk animal, within a distance of 8 km of the plant site, in each of the 9 meteorological sectors (per Control 3.12.2).

b)

Identify the location of the nearest residence, within a distance of 8 km of the plant site, in each of the 9 meteorological sectors (per Control 3.12.2).

c)

Identify the location of the nearest garden, within a distance of 8 km of the plant site, in each of the 9 meteorological sectors; or if the garden census was not conducted, obtain samples of three different kinds of broad leaf vegetation from the SITE BOUNDARY in two different meteorological sectors which have the highest predicted SITE BOUNDARY D/Q (per Control 3.12.2).'

3.

Surveillance Requirement(s) a)

Perform a land use census that will provide the best results. Example methods may include, but are not limited to, the following:

(1) door-to-door surveys (2) aerial views (3) consult local agricultural authorities b)

Document the results of the land use census in the Annual Radiological Environmental Operating Report in accordance with Technical Specification 5.6.2.

c)

Perform an Independent Technical Review of the land use census data.

4.

Responsible Company Organizations a)

The Chemistry Section, CCNPPI, is responsible for ensuring the performance of the surveillances listed above.

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 O T D

E L

A N

N Page 209 of 318

5.

Initiating conditions a)

Conduct the land use census during the growing season, and conduct the land use census at least once per 12 months.

6.

Calculation methodology a)

Calculate doses for the pathways of interest in accordance with the methodologies contained in Regulatory Guide 1.109, or b) if methodologies other than those listed in Regulatory Guide 1.109 are used to calculate doses, such methodologies should be documented in the Annual Radiological Environmental Operating Report.

7.

Corrective actions a)

The results of the land use census shall be used to determine the RADIOLOGICAL ENVIRONMENTAL MONITORING Programs sample locations identified on 3.

b)

If the land use census has identified a location(s) that yields a calculated dose or dose commitment greater than the values currently being calculated in Control 4.11.2.3, perform the following activities.

(1)

Document the new location(s) in the next Annual Radiological Environmental Operating Report in accordance with Technical Specification 5.6.2, and (2) revise the figures and tables in the ODCM to reflect the new location(s).

c)

If the land use census has identified a location(s) that yields a calculated dose or dose commitment (via the same exposure pathway) which is 20% greater than the equivalent location identified on Attachment 13, perform the following activities.

(1)

Add the new location(s) to the RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM within 30 days, (2) document the new location(s) in the next Annual Radiological Environmental Operating Report in accordance with Technical Specification 5.6.2, and (3) revise the figures and tables in the ODCM to reflect the new location(s).

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 210 of 31i8 INTERLABORATORY COMPARISON PROGRAM

1.

Introduction a) 10 CFR 50, Appendix I, Section IV.B.2 requires licensees to establish an environmental surveillance and monitoring program for the purpose of evaluating the relationship between quantities of radioactive material released in effluents and resultant radiation doses to individuals.

b)

Radiological environmental controls have been established to ensure that independent checks on the precision and accuracy of the measurements of radioactive material in environmental sample matrices are performed as part of the quality assurance program for environmental monitoring.

c)

These radiological environmental controls are described below.

2.

Controls on the Interlaboratory Comparison Program a)

Analyze INTERLABORATORY COMPARISON PROGRAM samples supplied by either the Commission or a Commission approved laboratory for all parameters listed on Attachments 15, 16, and/or 17, as applicable 1 (per Control 3.12.3).

3.

Surveillance Requirement(s) a)

A summary of the results obtained as part of the Interlaboratory Comparison Program shall be included in the Annual Radiological Environmental Operating Report pursuant to Technical Specification 5.6.2.

b)

This section of the ODCM shall describe the Interiaboratory Comparison Program.

4.

Responsible Company Organizations a)

The CHEMISTRY SECTION, CCNPPI, is responsible for ensuring performance of the surveillances listed above.

5.

Initiating conditions a)

Analyze INTERLABORATORY COMPARISON PROGRAM samples whenever they are supplied by either the Commission or a Commission approved laboratory.

6.

Calculation methodology a)

Analysis methods and Calculational methodologies used to satisfy the above surveillances shall be documented in approved procedures.

7.

Corrective actions a)

If analyses are not performed as required, document actions taken to prevent reoccurrence in the Annual Radiological Environmental Operating Report (AREOR) pursuant to Technical Specification 5.6.2.

Since no Commission approved laboratory supplies TLDs as part of a comparison program, no TLDs are analyzed as part of the INTERLABORATORY COMPARISON PROGRAM.

DRev.

00802 OFFSITE DOSE CALCULATION MANUAL Page 211 of 318 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT 1.

Introduction a) 10 CFR 50, Appendix I, Section IV.B.2 requires licensees to provide data on measurable levels of radiation and radioactive materials in the environment.

b)

Radiological environmental controls have been established to implement the requirements of 10 CFR 50, Appendix I, Section IV.B.2.

c)

These radiological environmental controls are described below.

2.

Controls on the Annual Radiological Environmental Operating Report (AREOR) a)

The AREOR shall include a summary description, of the radiological environmental monitoring program (REMP).

b)

The AREOR shall include a summary description of the Independent Spent Fuel Storage Installation Monitoring Program (ISFSIMP).

c)

The AREOR shall include a table similar to Attachment 13 which states the distance and direction from the central point between the two containment buildings to each of the REMP sample points.

d)

The AREOR shall include a table similar to Attachment 20 which states the distance and direction from the central point of the ISFSI to each of the ISFSIMP sample points.

e)

The AREOR shall include summaries, interpretations, and an analysis of trends of the results of the radiological environmental surveillance activities for the report period.

f)

The AREOR shall include a comparison between the annual REMP results and the Radiological Environmental Operating Report preoperational studies.

g)

The AREOR shall include a comparison between the annual ISFSIMP results and Radiological Environmental Operating Report pre-fuel-load-studies.

h)

The AREOR shall include a comparison with operational controls as appropriate.

i)

The AREOR shall include a comparison with the previous environmental surveillance reports.

j)

The AREOR shall include an assessment of the observed impacts of plant operation on the environment.

k)

The AREOR shall include an assessment of the observed impacts of ISFSI operation on the environment.

I)

The AREOR shall include the results of the land use censuses required by Control 3.12.2.

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 212 of 318 m)

The AREOR shall include the results of analysis of all radiological environmental samples taken during the period pursuant to the locations specified on Attachments 13 and 20.

n)

The AREOR shall include the results of all environmental radiation measurements taken during the period pursuant to the locations specified on Attachments 13 and 20.

0)

The AREOR shall include summarized and tabulated results--in the format of the table in the Radiological Assessment Branch Technical Position, Revision 1, November 1979--of analysis of all radiological environmental samples taken during the period pursuant to the locations specified on Attachments 13 and 20.

p)

The AREOR shall include summarized and tabulated results--in the format of the table in the Radiological Assessment Branch Technical Position, Revision 1, November 1979-of all environmental radiation measurements taken during the period pursuant to the locations specified on Attachments 13 and 20.

q)

The AREOR shall include an explanation for missing results, if some individual results (as described in the above paragraph) are not available for inclusion with the report.

r)

The AREOR shall include any data which was missing from previous reports.

s)

The AREOR shall include at least two legible mapslcovering all REMP sampling locations keyed to a table giving distances and directions from the central point between the two containment buildings.

t)

The AREOR shall include at least one legible map covering all ISFSIMP sampling locations keyed to a table giving distances and directions from the central point of the ISFSI.

u)

The AREOR shall include results of the licensee participation in the INTERLABORATORY COMPARISON PROGRAM required by Control 3.12.3.

v)

The AREOR shall include a discussion of all deviations from the sampling schedules listed on Attachments 14, 15, 16, and 17, and specify the reason(s) for the deviations, and the plan for preventing recurrence.

w)

The AREOR shall include a discussion of all analyses in which the LLD listed on Attachments 15, 16, and 17 (and required by Control Table 4.12-1) was not achievable.

x)

The AREOR shall include the identification of the cause of unavailability of samples (if any), and describe the locations used for replacement samples.

y)

The AREOR shall include any permanent changes in the sample locations in the monitoring program.

One map shall cover stations near the SITE BOUNDARY; a second shall include the more distant stations.

OFF8lTE DOSE CALCULATION MANUAL

,Rev.

00802 Page 213 of 318 z)

The AREOR shall include revised figure(s) (e.g., like Attachments 18 and 19) and tables (e.g., like Attachment 13) for the ODCM which reflect any new REMP sample location(s).

aa)

I The AREOR shall include revised figure(s) (e.g., like Attachments 21 and 22) and table(s) (e.g., like Attachment 20) for the ODCM which reflect any new ISFSIMP sample location(s).

bb)

The AREOR shall receive an independent review for technical content prior to submittal to the NRC.

cc)

Material provided in the AREOR shall be consistent with the objectives outlined in the ODCM and 10 CFR 50, Appendix I, Section IV.3.2, IV.3.3 and IV.C.

3.

Surveillance Requirement(s) a)

Write the Annual Radiological Environmental Operating Report covering the previous calendar year's operation of the reactor units.

4.

Responsible Company Organizations a)

The Chemistry Section, CCNPPI, is responsible for ensuring the performance of the surveillances listed above!.

5.

Initiating conditions a)

Submit the Routine AREOR (covering operation of the reactor units for the previous calendar year) of each year in accordance with Technical Specification 5.6.2.

6.

Calculation methodology a)

Calculational methodologies used to satisfy the above surveillances should be documented in approved procedures, or should be included in the AREOR.

7.

Corrective actions a)

If analyses are not performed as required, document actions taken to prevent reoccurrence in the AREOR pursuant to Technical Specification 5.6.2.

I A separate company may be contracted to complete the Routine AREOR.

Rev.

00802 OFFSITE DOSE CALCULATION MANUAL Pe 2

o8

  • Page 214 of 318 INDEPENDENT SPENT FUEL STORAGE INSTALLATION MONITORING PROGRAM
1.

Introduction a)

The Technical Specifications for the Independent Spent Fuel Storage Installation' (ISFSI), licensed under 10 CFR 72, require that monitoring for the ISFSI be added to the existing environmental monitoring program for CCNPP.

b)

CCNPP has committed to additional monitoring for the ISFSI.2 c)

Radiological environmental controls have been established to implement the requirements and commitments described above.

d)

These radiological environmental controls are described below.

2.

Controls on the ISFSI Monitoring Program a)

Environmental monitoring sites, as described in Attachment 20, shall be established to monitor the air, vegetation, and soil as well as direct radiation in the ISFSI environs.3 b)

Analysis parameters, analysis frequencies, detection limits, and ACTION levels shall conform to the applicable requirements of Controls 3.12.1. (See attachment 14, 15, 16, and 17) c)

Map(s) shall be maintained and shall show the locations of the environmental monitoring sites with respect to plant facilities. (See attachment 21 and 22).

3.

Surveillance Requirements a)

Surveillances for direct radiation (1)

Direct radiation dosimetry shall be collected from locations SFDR1-SFDR16, DR7, and DR30 listed in Attachment 20.

(2)

In the event any dosimetry at an existing monitoring location SFDR1-SFDR16, DR7, or DR30 becomes unavailable, place new dosimetry at the monitoring station.

(3)

Analyze the dosimeters at the frequencies and for the parameters identified on Attachment 14.

The Technical Specifications For Calvert Cliffs Independent Spent Fuel Storage Installation is Appendix "A' to Materials License SNM-2505.

2 See the letter titled "Response to NRC's Comments to Environmental Issues Regarding BGE's License Application for Calvert Cliffs Independent Spent Fuel Storage Installation (ISFSI)" from Mr. R. E. Denton (BGE) to Director, Office of Nuclear Material Safety and Safeguards (NRC), dated November 1, 1990.

Environmental monitoring sites and monitoring parameters specifically excluded from the ISFSIMP include airborne radioiodines, radioiodines in food products, surface water, and fish and invertebrates. Additionally, soil samples shall be collected in lieu of shoreline sediment. The sampling frequency for vegetation and soil shall be quarterly.

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 215 of 318 b)

Surveillances for airborne particulate activity (1)

Air particulate samples shall be collected from locations Al and SFA1-SFA4 listed.on Attachment 20.

(2)

In the event any particulate filter becomes unavailable from an existing monitoring location Al or SFA1-SFA4 described on Attachment 20, place a new particulate filter in the air sampler at the monitoring station.

(3)

Analyze the samples at the frequencies and for the parameters identified under "Particulate Filters" on Attachment 15.

c)

Surveillances for deposition on vegetation (1)

The vegetation samples SFbl-SFb5 shall be collected from the locations listed on Attachment 20.

(2)

In the event any of the sampling sites SFbl-SFb5 described on Attachment 20 become unavailable, establish new sampling sites as described below:

(a)

In lieu of sample SFbl, collect vegetation grown in the NW sector of the ISFSI.

(b)

In lieu of sample SFb2, collect vegetation grown in the general vicinity of the CCNPP Visitor's Center.

(c)

In lieu of sample SFb3, collect vegetation grown in the North North West sector of the ISFSI.

(d)

In lieu of sample SFb4, collect vegetation grown in the South-Southeast sector of the ISFSI.

(e)

In lieu of sample SFb5, collect vegetation grown in the East-Southeast sector of the ISFSI.

(3)

Analyze the samples quarterly for the non-iodine parameters identified under "Food -Products" on Attachment 17.

Rev.

00802 OFFSITE DOSE CALCULATION MANUAL DOE ANAL Page 216 of 318 d)

Surveillances for soil activity (1)

The soil samples SFS1-SFS5 shall be collected from the locations listed on 0.

(2)

In the event any of the sampling sites SFS1-SFs5 described on Attachment 20 become unavailable, establish new sampling sites as described below:

(a)

In lieu of sample SFS1, collect soil in the NW sector of the ISFSI.

(b)

In lieu of sample SFS2, collect soil in the general vicinity of the CCNPP Visitor's Center.

(c)

In lieu of sample SFS3, collect soil in the North North West sector of the ISFSI.

(d)

In lieu of sample SFS4, collect soil in the South-Southeast sector of the ISFSI.

(e)

In lieu of sample SFS5, collect soil in the East-Southeast sector of the ISFSI.

(3)

Analyze the samples quarterly for the parameters identified under "Shoreline Sediment Sample" on Attachment 16.

4.

Responsible Company Organizations a)

The CHEMISTRY SECTION, CCNPPI, is responsible for ensuring the performance of the surveillances listed above.

5.

Initiating conditions a)

Collect samples in accordance with the frequencies specified on Attachments 14, 15, 16, and 17. Soil and vegetation samples shall be collected quarterly.

b)

Analyze samples in accordance with the frequencies specified on Attachments 14, 15, 16, and 17. Soil and vegetation samples shall be analyzed quarterly.

c)

Calculate the potential annual doses in accordance with the methodology outlined elsewhere in this section if any of the following conditions are true:

(1) any of the above surveillance results reveal levels of environmental activity greater than the ACTION Levels specified on Attachments 14, 15, 16, and 17, as appropriate. (per Control Table 3.12-2), or (2) any radionuclides other than those listed on Attachments 14, 15, 16, and 17 are detected, and the radionuclides are the result of plant effluents or radionuclide deposition from the ISFSI, and the, potential annual doses due to the radionuclides are greater than the limits listed in Control 3.12.1.b.

d)

The Chemistry Section, CCNPPI, is responsible for notifying the General Supervisor-

-Chemistry, CCNPP, if any of the following conditions are true:

OFFSITE DOSE Rev.

00802 OECALCULATION MANUAL Page 217 of 318' (1) any of the above surveillance results reveal levels of environmental activity greater than the ACTION Levels specified on Attachments 14, 15, 16, and 17, as appropriate (per Control Table 3.12-2), or (2) any radionuclides other than those in Attachments 14, 15, 16, and 17 are detected, and the radionuclides are the result of plant effluents or radionuclide deposition from the ISFSI, and the potential annual doses due to the radionuclides are greater than the limits listed in Control 3.12.1.b.

6.

Calculation methodology a)

If any (of the above) surveillance results reveal levels of environmental activity greater than the ACTION Levels specified on Attachments 14, 15, 16, or 17 (per Control Table 3.12-2), calculate potential annual doses for the pathway of interest, in accordance with the methodologies contained in Regulatory Guide 1.109.

b)

If methodologies other than those listed in Regulatory Guide 1.109 are used to calculate potential annual doses, such methodologies shall be documented in accordance with Control 3.12.1.b.

7.

Corrective actions a)

If a sample is unobtainable due to sampling equipment malfunction, then attempt to restore equipment to operable status before the end of the next sampling period, and document in the AREOR.

b)

If the ISFSIMP is not being conducted in accordance with the "Surveillance Requirements" listed elsewhere in this section, document deviations in the AREOR.

c)

When the analysis result for any parameter exceeds the ACTION Level listed on Attachments 15, 16, or 17, as appropriate, submit a Special Report to the NRC (per Control 3.12.1.b).

d)

When radionuclides other than those listed on Attachments 15, 16, and 17 are detected, and when those radionuclides are the result of plant effluents or radionuclide deposition from the ISFSI, submit a, Special Report if required by and in accordance with Control 3.12.1.b.

SDATRev.

00802 OFFSlTE DOSE CALCULATION MANUAL Page 218 of 318 RADIOACTIVE EFFLUENT RELEASE REPORT INTRODUCTION

1.

Technical Specification 5.6.3 requires submittal of a written report to the NRC every 12 months.

2.

The report is described below.

RESPONSIBILITIES

1.

The General Supervisor Chemistry is responsible for the timely and accurate completion of the report.

REPORT CONTENTS

1.

The Radioactive Effluent Release Report (RERR) covering the operation of the unit shall be submitted every 12 months in accordance with 10 CFR 50.36a.

2.

The RERR shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the units. The material provided shall be consistent with the objectives outlined in the ODCM and in conformance to 10CFR50.36a and 10CFR50, Appendix I, section IV.B.1. Principle Gamma Emitters from Batch Waste Releases and Turbine Building Sump shall be analyzed and included in this report pursuant to Table Notation c of Control Table 4.11-1, "Radioactive Liquid Waste Sampling and Analysis Program." In addition, Principal Gamma Emitters from the Waste Gas Storage Tank, Containment Purge and Vent, and the Main Vent shall be analyzed and included in this report pursuant to Table Notation b of Controls Table 4.11-2, "Radioactive Gaseous Waste Sampling and Analysis Program." Additional information which may be required in the report is contained in Controls 3.3.3.9.b, 3.3.3.10.b and Technical Specification 5.6.3.

3.

The RERR shall include an annual summary of hourly meteorological data collected over the previous year. This annual summary may be either in the form of an hour-by-hour listing on magnetic tape of wind speed, wind direction, atmospheric stability, and precipitation (if measured), or in the form of joint frequency distributions of wind speed, wind direction, and atmospheric stability.1 This same report shall include an assessment of the radiation doses due to the radioactive liquid and gaseous effluents released from the unit or station during the previous calendar year. The assessment of radiation doses shall be performed in accordance with the methodology and parameters in the OFFSITE DOSE CALCULATION MANUAL (ODCM).

4.

The RERR shall also include an assessment of radiation doses to the likely most exposed MEMBER OF THE PUBLIC from reactor releases and other nearby uranium fuel cycle sources, including doses from primary effluent pathways and direct radiation, for the previous calendar year to show conformance with 40 CFR Part 190, Environmental Radiation Protection Standards for Nuclear Power Operation. Acceptable methods for calculating the dose contribution from liquid and gaseous effluents are given in Regulatory Guide 1.109, Rev. 1, October 1977, and NUREG-0133, "Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants."

In lieu of submission with the Radioactive Effluent Release Report, this summary of required meteorological data may be retained on site in a file that shall be provided to the NRC upon request.

DRev.

00802 OFFSITE DOSE *CALCULATION MANUAL Page 219 of 318

5.

The RERR shall include the following information for each class of solid waste (as defined by 10 CFR Part 61) shipped offsite during the report period:

a.

Container volume,

b.

Total curiequantity (specify whether determined by measurement or estimate),

c.

Principal. radionuclides (specify whether determined by measurement or estimate),

d.

Source of waste and processing employed (e.g., dewatered spent resin, compacted dry waste, evaporator bottoms),

e.

Solidification agent or absorbent (e.g., cement).

6.

The RERR shall include a list and description of unplanned releases from the site to UNRESTRICTED AREAS of radioactive materials in gaseous and liquid effluents made during the reporting period.

7.

The RERR shall include any changes made during the reporting period to the OFFSITE DOSE CALCULATION MANUAL (ODCM) and a listing of new locations for dose calculations identified by the annual land use census pursuant to Control 3.12.2.

8.

The RERR shall include any changes made during the reporting period to the PROCESS CONTROL PROGRAM (PCP)1 The report shall contain:

a.

A description of the equipment, components and processes involved.

b.

Documentation of the fact that the change, including, the safety analysis, was reviewed and found acceptable by the POSRC.

REPORT SUBMITTAL

1.

Prior to submittal a Independent Technical Review will be performed.

2.

The RERR will be submitted every 12 months in accordance with 10 CFR 50.3,6a and 50.4.

Licensee initiated changes to the PCP shall become effective upon review by the POSRC and approval of the Plant General Manager.

D C

URev.

00802 OFFSlTE DOSE CALCULATION MANUAL Page 220 of 318 ADMINISTRATION OF THE ODCM INTRODUCTION

1.

Procedures covering the ODCM and the implementation of the ODCM shall be implemented.

2.

Administrative controls have been established to implement controls on the ODCM.

3.

These administrative controls are described below.

CONTROLS ON THE ODCM

1.

The format, organization, content, and administration of the ODCM are controlled by CH-1-103.

2.

Methodologies identified in the ODCM are implemented by various CCNNPI organizations in accordance with approved procedures. (See the "RESPONSIBILITIES" section of CH-1-103 for a list of those Sections of CCNNPI responsible for approving and maintaining procedures which implement the requirements of the ODCM.)

3.

The main vent stack flow rates shall be verified in accordance with the surveillances described in the following section, "Surveillance Requirements".

4.

Licensee initiated changes to the ODCM:

a)

Shall be documented and records of reviews performed shall be retained. This documentation shall contain (1)

Sufficient information to support the change(s) together with the appropriate analyses or evaluations justifying the change(s);

(2)

A determination that the change(s) maintain the levels of radioactive effluent control required by 10 CFR 20 (1990), 10 CFR 20.1302, 40 CFR Part 190, 10 CFR 50.36a, and 10 CFR Part 50, Appendix I, and not adversely impact the accuracy or reliability of effluent dose, or setpoint calculations; b)

Shall become effective upon review by the onsite review function and approval of the plant manager; and c)

Shall be submitted to the NRC in the form of a complete, legible copy of the entire ODCM as part of or concurrent with the Radioactive Effluent Release Report for the period of the report in which any change in the ODCM was made. The copy 0

submitted to the NRC shall include markings in the margin of the affected pages, clearly indicating the area of the page that was changed and shall indicate the date (for example, month and year) the change was implemented.

DARev.

00802 OFFSITE DOSE CALCULATION MANUAL Page 221 of 318 Surveillance Requirements

1.

Complete audits and PERIODIC REVIEWS of the ODCM in accordance with CH-1-103.

2.

Determine main vent stack flow rates for both units as described below.

a)

The main vent stack flow rate shall be determined, in accordance with approved procedures, at least once per 6 months L+ 2 5%).

b)

The Electrical and Control Section shall be responsible for performing this test.

c)

The results of the main vent flow rate test shall be evaluated to ensure the main vent flow rates used in the ODCM are an accurate reflection of the true main vent flow rates.

d)

IF the main vent stack flow rate for either unit, as determined in accordance with approved Test and Equipment procedure(s), changes + 10% from the values referenced in Attachment 7 of the ODCM, a technical evaluation shall be initiated to determine if the ODCM should be revised.

RESPONSIBLE COMPANY ORGANIZATIONS

1.

CH-1-103 identifies the responsibilities of various personnel and company organizations which administer and implement the ODCM. This section of the ODCM identifies company organizations which are assigned responsibility for implementing the surveillances described above.

2.

The Electrical and Control Section is responsible for ensuring the main vent stack flow rate test procedure (e.g., STP-M-462-1, STP-M-462-2 or equivalent) is completed in accordance with the surveillances listed above.

3.

The Electrical and Control Section is responsible for forwarding main vent stack flow rate test results to the General Supervisor - Chemistry.

4.

The RETS Program Manager, CCNPPI CHEMISTRY SECTION, is responsible for evaluating main vent flow rate test results (e.g., STP-M-462-1, STP-M-462-2 or equivalent results) and for performing the technical evaluation described in the above surveillances.

INITIATING CONDITIONS

1.

Main vent stack flow rates shall be determined at least once per 6 months (+ 25%), or more often if required by Controls.

2.

Complete PERIODIC REVIEWS of the ODCM as specified in CH-1-103.

SDATRev.

00802 OFFSlTE DOSE CALCULATION MANUAL Page 222 of 318 CALCULATION METHODOLOGIES

1.

Calculational methodologies used to satisfy the above surveillances should be documented in approved procedures.

2.

Documents which serve as a basis for calculation methodologies used in the ODCM should be maintained in an accessible location.

(1)

Supporting documents may be incorporated into the ODCM (e.g., as Attachments).

(2)

Supporting documents may be maintained in a "procedure history file".

(3)

Supporting documents may be identified in the "references" section of the ODCM.

CORRECTIVE ACTIONS

1.

IF main vent stack flow rates, as determined in accordance with appropriate Test Equipment procedure(s), change + 10% from the values referenced in Attachment 7 of the ODCM, a technical evaluation shall be initiated to determine if the ODCM should be revised.

BASES

1.

[B527], NRC Inspection Report INSR 91-30/30

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 223 of 318 Attachment I Final Grading And Drainage Plan A reference diagram which depicts the grading for and the drainage from the Calvert Cliffs Nuclear Power Plant can be found in the following reference:

Final Grading And Drainage Plan Calvert Cliffs Nuclear Power Plant Units 1 and 2, BGE Document ID Number: 61517SH0001 BGE Document ID Number: 61514SH0002 The above referenced grading and drainage plan is intended for reference only. This drawing may not reflect the changes and modifications since March 1975.

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 224 of 318 Sources of Liquid Radioactive Waste Waste Stream Radiation Type of Monitor Release Max. Di FloA gal/min Rx. Coolant Wst. Mon. Tk.

Rx. Coolant Wst. Rec. Tk.

Misc. Wst. Mon. Tk.

Misc. Wst. Rec. Tk.

Aux. Boiler Steam Drum Aux. Blowdown Tk.

Waste Neut. Tk. 11 Waste Neut. Tk. 12 Stm. Gen. Blowdown Tk.

Component Cooling Water4 Condenser Hotwells Salt Water System Condensate Storage Tank Demin. Water Storage Tank Precoat Sump 0-RE-2201 0-RE-2201 0-RE-2201 0-RE-2201 All releases are Unmonitored Unmonitored Unmonitored 1/2-RE-401414 Unmonitored Unmonitored Unmonitored Unmonitored Unmonitored Unmonitored.

Batch 120 Batch 120 Batch 120 Batch 120 via Auxiliary Blowdown Tank Continuous 20012 Batch 10001 Batch 10001 Continuous/

2252 Batch11 Continuous variable 5 Batch10 45007 Continuous 15500 Batch Variable 8 Batch Variable 8 Continuous 50 scharge Rate liters/min 454 454 454 454 757 37901 37901 8522 variable 5

170007 58670 Variable 8

Variable 8

94.6 gal 9000013 9000013 400013 400013 N/A 45988.

47749 23503 440906 1.05E5 N/A 3.5E5 9 -

3.5E5 9 103053 Maximum Volume Notes liters 3.407E5 13 3.407E5 13 1514013 1514013 N/A 1.74E5 1.80E5 88953 1.669E5 3.97E5 N/A 1.3E6 9 1.3E6 9 390043

OFFSITE DOSE CALCULATION MANUAL Rev.

-00802 Page 225 of 318 Sources.of Liquid Radioactive Waste Waste Stream Radiation Type of

'Monitor Release Aux. Building Roof Drains 1 9 Sewage:Treatmbnt Plant Turbine Bldg. Sump No. 11 Turbine Bldg. Sump No. 12 Turbine Bldg. Sump No. 21 Turbine Bldg. Sump No. 22 Diesel Oil Interceptor Sump Yard Oil Interceptor Refueling Water Tank Condensate Storage Tank Service Water System Plant Heating System 1 8 Unmonitored Unmonitored Unmonitored Unmonitored Unmonitored Unmonitored Unmonitored Unmonitored Unmonitored Unmonitored 1/2-RE-1 595 Unmonitored Continuous

.Continuous Continuous Continuous Continuous Continuous Continuous Continuous Batch/Cont. 17 Batch/Cornt.17 Continuous Continuous Max. Discharge Flow Rate Gal/min liters/min Variable Variable 185 700 470-889 470 889 470 889 470 889 100 378.5 variable 15 variable 15 variable 15 variable 15 variable 15 variable1 5 variable 15 variable 15 variable 15 variable 15 gal liters

.Maximum Volume Notes N/A N/A 1950 2415 2490 2182 5790 N/A 4.2E5 3.5E5 16 31418 N/A N/A N/A 7381 9141 9425 8259 21920 N/A 1.6E6 1.3E6 16 1.189E5 N/A

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 226 of 318 Sources of Liquid Radioactive Waste

1.

This flow-rate is only an approximation. The motive force is gravity

2.

This is the maximum flow rate. The actual flow rate will be considerably less.

3.

This is the maximum volume of the tank for a BATCH RELEASE. If the release is a CONTINUOUS RELEASE, the volume discharged would be calculated from the discharge flow rate and duration of the release.

4.

There is no direct path by which radioactive liquid from the CCW System could enter outfall 001. Liquid from the CCW System may leak into either the Salt Water System (which drains to outfall 001) or the Liquid Waste Processing System (via Aux. Bldg. Drains).

5.

Radioactive liquid is not normally released from the CCW system. Flow rate to outfall 001 may occur via Salt Water System. For this pathway, the flow rate will vary (e.g., depending on size of leak). See Safety Analysis No. 2, FCR 82-1053, Supplement 1.

6.

System volume is 5894 cubic feet. Conversion constant is 0.13368 cubic feet per gallon.

7.

The flow rate shown here. is the flow rate for one condensate pump. Verify the number on condensate pumps in service, and modify this flow rate accordingly.

8.

Flow rate should be calculated on a case-by-case basis.

9.

Volume obtained from "Plant Data Book", BGE CCNPP Units 1 and 2, Bechtel Power Corporation, Volume 1, Job 6750.

10.

May be a CONTINUOUS RELEASE if contaminated sealing steam is operated during the release.

11.

Although steam generator releases may be either CONTINUOUS RELEASES or BATCH RELEASES. Verify type of release to be conducted prior todischarge.

12.

This is the maximum rated discharge for two pumps in operation.

13.

The volume specified is the design basis volume from Table 11-1 of the UFSAR.

14.

The steam generator blowdown effluent radiation monitor, 1/2-RE-4095, may be equivalent to the 1/2-RE-4014 (see part 5, Liquid Effluent Radiation Monitor Alarm and Fixed Setpoints, para, 2)

15. Maximum discharge flow rate shall be determined on a case-by-case basis.
16.

Volume obtained from "Plant Data Book", BGE CCNPP-Units 1 and 2, Bechtel Power Corporation; Volume 1, Job 6750.

17.

Releases via this pathway would be considered a BATCH RELEASE if a catastrophic tank failure occurred. In the event of a small leak, the.release may be considered a CONTINUOUS RELEASE. The release mode should be determined on a case-by-case basis.

18.

The plant heating system is a closed system and is not normally released to the environment. In the event of a leak, the effluent may be released to the environment via the turbine building sumps. In some cases, depending on the location of the leak, the effluent would be collected in the auxiliary building sump and subsequently released through the liquid radioactive waste processing system. The effluent pathway should be determined on a case-by-case basis.

19.

Plant drawings indicate that these drains discharge to outfalls 003 and 004.

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 227 of 318 (This page intentionally left blank.)

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 228 of 318 Block Diagram of Liquid Radioactive Waste Systems Reactor Coolant Waste Miscellaneous Waste Turbine Bldg..

Sump Chesapeake Circulating Water Bay

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 229 of 318 Radionuclides in Typical Radwaste Discharges The term fi -- a fraction which represents the relative activity contribution of.nuclide i to the average total effluent activity -- is,used in several equations in the 0DCM (e.g., equations 2G, 5G, 3L, and 4L). This attachment provides guidance for calculating the values of fi.

1.

Select the calendar quarters which contain at least one "typical" liquid (or gas) release (see definition of TYPICAL RADWASTE RELEASE).

2.

For each of the calendar quarters selected above, obtain a listing of the nuclides, nuclide activities, and release (end) dates.

a.

This data may be obtained from the Radioactive Effluent Release Report(s) for the time periods of interest, or

b.

This data may be obtained from a computer-based effluent management system (if available).

c.

The values of nuclide activities and release end times may be close approximations of the true values.

3.

Sum the quarterly activities (curies) for each individual radionuclide.

AIT

=

A-Q Eq. IR

4.

Sum the quarterly activities for all radionuclides, AT

=

-AIT Eq. 2R

5.

Calculate the fraction of the total activity attributable to each radionuclide (i.e., the relative activity of nuclide i).

f

=

AIT AT Eq. 3R

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 230 of 318 Liquid Effluent Dose Factors (mrem/hr per uCi/ml)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gltract H-3 BE-7 C-14 NA-24 P-32 CR-51 MN-54 MN-56 FE-55 FE-59 CO-57 CO-58 CO-60 NI-63 NI-65 CU-64 ZN-65 ZN-69 BR-82 BR-83 BR-84 BR-85 RB-86 RB-88 RB-89 SR-89 SR-90 SR-91 SR-92 Y-90 Y-91 M Y-91 Y-92 Y-93 ZR-95 ZR-97 NB-95 NB-97 O.OOOE+00 2.700E+01 1.450E+04 4.570E-01 4.690E+06 O.OOOE+00 O.OOOE+00 O.OOOE+00 5.11 OE+04 8.060E+04 O.OOOE+00 O.OOOE+00 O.OOOE+O0 4.960E+04 2.020E+02 O.OOOE+O0 1.61 OE+05 3.430E+02 O.OOOE+O0 0.000E+00 O.OOOE+00 O.OOOE+O0 O.OOOE+00 O.OOOE+00 O.OOOE+00 4.990E+03 1.230E+05 9.180E+01 3.480E+01 6.060E+00 5.730E-02 8.880E+01 5.320E-01 1.690E+00 1.590E+01 8.810E-01 4.470E+02 3.750E+00 2.820E-01 1.100E+01 2.900E+03 4.570E-01 2.91 OE+05 O.OOOE+00 7.060E+03 1.780E+02 3.530E+04 1.900E+05 1.420E+02 6.030E+02 1.730E+03 3.440E+03 2.620E+01 2.140E+02 5.130E+05 6.560E+02 O.OOOE+00 O.OOOE+00 O.OOOE+O0 O.OOOE+00 6.240E+02 1.790E+00 1.190E+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+O0 5.11OE+O0 1.780E-01 2.490E+02 9.490E-01 2.820E-01 6.500E+01 2.900E+03 4.570E-o01 1.810E+05 5.580E+00 1.350E+03 3.150E+01 8.230E+03 7.270E+04 2.360E+02 1.350E+03 3.820E+03 1.670E+03 1.200E+01 1.010E+02 2.320E+05 4.560E+01 4.070E+00 7.250E-02 9.390E-02 3.860E-03 2.910E+02 9.490E-01 8.340E-01 1.430E+02 3.010E+04 3.71 OE+00 1.510E+00 1.630E-01 2.220E-03 2.370E+00 1.560E-02 4.660E-02 3.460E+00 8.130E-02 1.340E+02 3.460E-01 2.820E-01 1.300E+00 2.900E+03 4.570E-01 0.OOOE+00 3.340E+00 0.OOOE+00 0.OOOE+O0 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOEI-00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.820E-01 1.600E+01 2.900E+03 4.570E-01 0.OOOE+00 1.230E+00 2.100E+03 2.260E+02 0.OOOE+00 0.OOOE+00 0.OOOE+O0 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.400E+02 3.430E+05 4.260E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 8.020E+00 2.680E-01 2.460E+02

1. 11 OE+00 2.820E-01 3.1 OOE+00 2.900E+03 4.570E-01 0.OOOE+0O 7.400E+00 0.OOOE+00 0.OOOE+00 1.970E+04 5.300E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.820E-01 2.700E+02 2.900E+03 4.570E-01 5.270E+05 1.400E+03 2.160E+04 5.670E+03 2.030E+04 6.320E+05 3.590E+03 1.220E+04 3.250E+04 7.180E+02 6.650E+02 1.830E+04 3.230E+05 9.850E+01 4.670E+00 1.040E-01 7.370E-07 0.OOOE+00 1.230E+02 O.OOOE+O0 0.OOOE+00 8.OOOE+02 3.550E+03 4.370E+02 6.900E+02 6.420E+04 1.680E-01 4.890E+04 9.320E+03 5.350E+04 1.620E+04 5.510E+04 1.510OE+06 3.500E+03

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 231 of 318 r-------- -------------

Liquid Effluent Dose Factors (mrem/hr per uCi/mi)

Nuclide Bone Liver Tbody MO-99 TC-99M TC-101 RU-103 RU-i105 RU-106 RH-103M RH-106 CD-109 AG-110M SN-113 SB-122 SB-124 SB-125 TE-125M TE-127M TE-127 TE-129M TE-129 TE-131M TE-131 TE-132 1-130 1-131 1-132 1-133 1-134 1-135 CS-134 CS-136 CS-137 CS-138 BA-139 BA-140 BA-141 0.OOOE+00 1.280E+02 2.430E+01 1.300E-02 3.660E-02 4.660E-01 1.330E-02 1.920E-02 1.880E-01 1.070E+02 0.OOOE+00.

4.600E+01 8.890E+00 0.OOOEt00 3.510E+00 1.590E+03 0.OOOE+00 2.010E+02-0.OOOE+00 0.OOOE+00 0.000E+00 0'000E+00 0.OOOE+00 0.OOOE+00 2.100E+05 4.OOOE+06 1.600E+06 1.560E+03 1.450E+03 8.600E+02 6.700E+03 1.200E+03 2.100E+04 5.300E+01 5.520E+01 6.690E+02 2.770E+02 5.230E+00 1.100E+02 1.770E+02 1.980E+00 4.210E+01 2.170E+02 7.860E+01 2.910E+01 5.480E+02 1.960E+02 6.680E+01 8.900E+00 3.200E+00 1.930E+00 9.310E+02 3.470E+02 1.470E+02 2.540E+00 9.550E-01 6.190E-01 1.400E+02 6.850E+01 5.710E+01 1.590E+00 6.660E-01 5.030E-01 2.040E+02 1.320E+02 1.240E+02 3.960E+01 1.170E+02 4.610E+01 2.180E+02 3.120E+02 1.790E+02 i.060E+01 2.850E+01 9.960E+00 7.450E+01 1.300E+02 3.950E+01 5.560E+00 1.510E+01 5.400E+00 2.320E+01 6.080E+01 2.240E+01 6.840E+03 1.630E+04 1.330E+04 7.160E+02 2.830E+03 2.040E+03 8.770E+03 1.200E+04 7.850E+03 6.070E+00 1.200E+01 5.940E+00 7.850E+00 5.590E-03 2.300E-01 1.640E+03 2.060E+00 1.080E+02 3.810E+00 2.880E-03 1.290E-01 Thyroid Kidney Lung Gitract 0.OOOE+00 2.890E+02, 0.OOOE+00 2.960E+02 0.OOOE+00 5.560E-01 1.790E-02 2.170E+01 O.OOOE+00 3.460E-01 9.81 OE-03.

0.OOOE+00 0.OOOE+00 4.070E+02 0.OOOE+00 1.250E+04 0.OOOE+00 1.150E+02 o.OOOE+00 5.440E+03 0.OOOE+00 3.060E+03 0.OOOE+00 1.030E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.500E+05 2.200E+07 1.800E+05 2.500E+06 0.OOOE+00 2.850E+03 0.OOOE+00 5.910E+05 6.200E+02 1.600E+03 7.300E+02 2.200E+05 8.780E+00 2.610E+01 1.140E+01 6.580E+03 6.710E-01 0.OOOE+00 2.150E+02 7.860E+03 1.800E-01 0.OOOE+00 1.360E+02 1.950E+03 6.520E+01 8.820E+02 0.OOOE+00 8.660E+02 1.400E+02 2.230E+03 0.OOOE+00 1.840E+03 6.600E+00 3.630E+01 0.OOOE+00 7.030E+02 3.200E+02 3.890E+03 0.OOOE+00 4.690E+03 1.950E+00 1.070E+01 0.OOOE+00 1.920E+00 1.080E+02 6.940E+02 0.OOOE+00 6.800E+03 1.310E+00 6.990E+00 0.OOOE+00 2.260E-01 1.460E+02 1.270E+03 0.OOOE+00 6.240E+03 9.910E+03 1.820E+02 0.OOOE+00 1.010E+02 1 020E+05 5.350E+02 0.OOOE+00 8.230E+01 9.960E+02 4.540E+01 0.OOOE+00 5.350E+00 1.900E+04 2.260E+02 0.OOOE+00 1.160E+02 2.620E+02 2.400E+01 0.OOOE+00 1.320E-02 4.010E+03 9.750E+01 0.OOOE+00 6.870E+01 0.OOOE+00 5.270E+03 1.750E+03 2.850E+02 0.OOOE+00 1.570E+03 2.160E+02 3.21 OE+02 0.OOOE+00 4.070E+03 1.350E+03 2.320E+02 0.OOOE+00 8.810E+00 8.700E-01 5.120E-05 0.OOOE+00 5.230E-03 3.170E-03 1.390E+01 0.OOOE+00 7.020E-01 1.180E+00 3.380E+03 0.OOOE+00 2.680E-03 1.630E-03 1.800E-09

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 232 of 318 mm---

mm----mmm-----m-....mmm-mmmmm-------------------------------------------ml Liquid Effluent Dose Factors (mrem/hr per uCi/ml)

Nuclide Bone Liver Thody Thyroid Kidney Lung Gltract BA-142 LA-140 CE-139 LA-142 CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 EU-1 54 EU-155 W-187 NP-239 HG-203 1.720E+00 1.570E+00 1.000E+02 8.060E-02 3.430E+00 6.040E-01 1.790E+02 5.790E+00 1.900E-02 3.960E+00 3.870E+02 5.420E+01 9.160E+00 3.530E-02 1.400E+05 1.770E-03 7.940E-01 4.800E+01 3.670E-02 2.320E+00 4.460E+02 7.470E+01 2.320E+00 7.870E-03 4.580E+00 4.760E+01 7.68E+00 7.660E+00 3.470E-03 O.OOOE+00 1.080E-01 2.100E-01 3.700E+02

9. 130E-03 2.630E-01 4.940E-02 9.590E+00 2.870E-01 9.640E-04 2.740E-01 3.390E+01 4.960E+00 2.680E+00 1.910E-03 1.600E+05 O.OOOE+00 O.OOOE+00 6.200E-01 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 0.000E+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.500E-03 O.OOOE+O0 3.400E+01 O.OOOE+O0 1.080E+O0 1.970E-01 4.430E+01 1.340E+00 4.440E-03 2.680E+00 2.280E+02 3.550E+01 O.OOOE+O0 1.080E-02 1.600E+06 1.OOOE-03 O.OOOE+00 4.800E+00 O.OOOE+00 O.OOOE+00 O.OOOE+O0 O.OOOE+O0 O.OOOE+O0 O.OOOE+O0 O.OOOE+O0 O.OOOE+O0 O.OOOE+O0 O.OOOE+O0 O.OOOE+O0 1.000E+05 O.OOOE+00 5.830E+04 3.200E+03 2.680E+02 8.860E+03 1.670E+04 6.040E+04 2.540E+04 2.730E-09 2.200E+04 3.450E+04 6.050E+03 2.51 OE+03 7.11OE+02 3.200E+05

OFFSITE DOSE CALCULATION MANUAL Rev.

Page 00802 233 of 318 General Information Waste Stream Radiation Monitor Waste Gas System (WGDT)

Cntmt. Vent (via H2 Purge)

Unit 1 Cntmt. Purge (100%)

Unit 2 Cntmt. Purge (100%)

Unit 1 Main Vent Release Unit 2 Main Vent Release 0-RE-2191' 1/2-RE-541 52 1-RE-541 54 7

2-RE-5415 4

1 -RE-5415 7

2-RE-541 5 Related to Gaseous Releases via the Main Vents Type of Nominal Discharge Maximum Discharge release Flow Rate Flow Rate mr / sec SCFM ms/sec SCFM Batch N/A N/A 2.36E-2 50 Batch3 2.36E-2 50 2.93E-1 620 Continuous5 N/A N/A 22.46 47,3876 5

Continuous N/A N/A 20.98 44,3208 Continuous 56.39 1193399 62.01" 13127310 Continuous 42.7 905009 47.0 9955010 Note Since the WGDT is released to the plant vent stack, 1/2-RE-5415 and 1/2-RE-5416 may also be used to monitor releases from a WGDT.

2 The WRGM, 1/2-RE-5416, may also monitor these releases.

3 A containment vent is considered a "batch" release (even though inleakage of radioactive gases into the containment atmosphere may occur during the time the vent is in progress).

The WRGM, 1-RE-5416, may also monitor these releases.

A purge is considered to be a CONTINUOUS RELEASE due to potential introduction of radioactive gases to the containment atmosphere during containment maintenance activities.

6 This is the purge flow rate as determined by approvedtest procedure (i.e., TE-006) in April 1998.

7 The WRGM, 2-RE-5416, may also monitor these releases.

a Thisis the purge flow rate asdetermined by approved test procedure (i.e., TE-006) in March 2001.

9 This is the mean main vent stack flow rate as determined by approved test procedure (i.e., TE-001 from 8/1990-3/1996 for Unit 1 and TE-001 from 8/1990-3/2000 for Unit 2 or STP-M-462-1 for Unit 1 and.STP-M-462-2 for Unit 2 beginning in May 2002).

This is the maximum vent stack flowrate which is equal to 110% of the Nominal Discharge Flow rate.

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 234 of 318 General Information Related to Gaseous Releases via Pathways Waste Streams Radiation Monitor Type of Release other than the Main Vents Nominal Discharge Notes Flow Rate Aux. Boiler Deaerator Stm. Gen. Atm. Stm. Dumps Plant Nitrogen System Turbine Bldg. Vent. Exh3 Emergency Air Lock Plant Compressed Air Main Steam Line Penetrations Steam Driven Auxiliary Feed Pumps Containment Equipment Hatch Unmonitored Unmonitored Unmonitored Unmonitored Unmonitored Unmonitored Unmonitored Unmonitored Unmonitored See Footnote1 See Footnote1 See Footnote1 See Footnote1 See Footnote1 See Footnote1 See Footnote1 See Footnote1 See Footnote1 See Footnote2 See Footnote 2 See Footnote 2 See Footnote 2 See Footnote2 See Footnote2 See Footnote2 See Footnote2 See Footnote2 1

Since radioactive gaseous waste. is notnormally vented via this pathway, the determination of release type (i.e., continuous or batch) will be evaluated on a case-by-case basis.

2 Since radioactive gaseous waste is not normally vented via this pathway, the determination of discharge flow rate will be evaluated on a case-by-case basis.

Includes sources such as Gland Seal Exhaust.

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 235 of 318 Block Diagram of Gaseous Radioactive Waste Systems Ap

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 236 of 318 NUCLIDE Ar-41 Kr-85 Kr-85m Kr-87 Kr-88 Xe-131m Xe-1 33 Xe-1 33m Xe-1 35 Xe-1 35m Xe-138 GAMMA BODY DOSE K,

(mromlyr)I(pCi/m3) 8.84E+03 1.61 E+01 1.17E+03 5.92E+03 1.47E+04 9.15E+01 2.94E+02 2.51 E+02 1.81E+03 3.12E+03 8.83E+03 0 Noble Gas Dose Factors BETA SKIN DOSE GAMMA AIR DOSE Li M,

(mremlyr)I(pCilm3)

(mradlyr)/(pCI/m3) 2.69E+03 9.30E+03 1.34E+03 1.72E+01 1.46E+03 1.23E+03 9.73E+03 6.17E+03 2.37E+03 1.52E+04 4.76E+02 1.56E+02 3.06E+02 3.53E+02 9.94E+02 3.27E+02 1.86E+03 1.92E+03 7.11E+02 3.36E+03 4.13E+03 9.21E+03 BETA AIR DOSE Nj (mradlyr)I(pCI/m3) 3.28E+03 1.95E+03 1.97E+03 1.03E+04 2.93E+03 1.11 E+03 1.05E+03 1.48E+03 2.46E+03 7.39E+02 4.75E+03

Rev.

00802 OFFSITE DOSE CALCULATION MANUAL Page 237 of 318 1 Empirical Derivation Of Site-Specific Dose Factors The total body dose, the skin dose, and the air doses--resulting from gamma and beta emitting radionuclides in discharges of gaseous radwaste--are normally calculated using nuclide specific dose factors. However, these same doses may be estimated using empirically derived, site specific, dose factors as shown below.

TOTAL-BODY, GAMMA-DOSE FACTOR A site-specific, total-body, gamma-dose factor has been derived from historical data in accordance with the following equation.

Ka

=

( Kl)'(fl)

Eq. IF Kav0

=

the empirically derived, site-specific, total-body, gamma-dose factor due to all noble gases released during a specified time period Values of Kavg have been calculated using gaseous radwaste discharge data collected over several years.

The results of the calculations appear in the Table on page 5 of this attachment.

Ki

=

the total body dose factor due to gamma emissions for each identified noble gas radionuclide, i (mrem/yr per microcurie/cubic meter)

The total-body dose factors for gamma rays from noble gas radionuclides were obtained from Regulatory Guide 1.109, Appendix B, Table B-1.

The total-body dose factors for various noble gas radionuclides are tabulated in Attachment 10.

f

=

a fraction which represents the relative activity contribution of noble gas radionuclide i to the total noble gas activity for TYPICAL GASEOUS EFFLUENTS (unitless)

This value has been calculated for all gaseous radwaste discharges for the years 1986, 1987, and 1988 in accordance with equation 3R on Attachment 5.

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 238 of 318 1 Empirical Derivation of Site-Specific Dose Factors SKIN, BETA-DOSE FACTOR A site-specific, skin, beta-dose factor has been derived from historical data in accordance with the following equation.

Lav9

=

,(

fl) )

Eq. 2F]

Lav9

=

the empirically derived, site-specific, skin, beta-dose factor due to all noble gases released during a specified time period Values of Lavg have been calculated using gaseous radwaste discharge data collected over several years.

The results of the calculations appear in the Table on page 5 of this attachment.

Li

= the skin dose factor due to beta emissions for each identified noble gas radionuclide, i (mrem/yr per microcurie/cubic meter)

The beta skin dose factors have been obtained from Regulatory Guide 1.109, Appendix B, Table B-I.

The beta skin dose factors for various noble gas radionuclides are tabulated in Attachment 10.

f

=

a fraction which represents the relative activity contribution of noble gas radionuclide i to the total noble gas activity for TYPICAL GASEOUS EFFLUENTS (unitless)

This value has been calculated for all gaseous radwaste discharges for the years 1986, 1987, and 1988 in accordance with equation 3R on Attachment 5.

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 239 of 318 1 Empirical Derivation of Site-Specific Dose Factors GAMMA-AIR-DbSE FACTOR A site-specific, gamma-air-dose factor has been derived from historical data in accordance with the following equation.

Mavg

=

(MI)

(f1 )

Eq. 3F Mavg

= the empirically derived, site-specific, gamma-air-dose factor due to all noble gases released during a specified time period Values of Mavg have been calculated using gaseous radwaste discharge data collected over several years.

The results of the calculations appear in the Table on page 5 of this attachment.

Mi

= the air dose factor due to gamma emissions for each identified noble gas radionuclide, i (mrad/yr per microcurie/cubic meter)

The gamma air-dose factors have been obtained from Regulatory Guide 1.109, Appendix B, Table B-1.

The gamma air dose factors for various noble gas radionuclides are tabulated in Attachment 10.

fi

= a fraction which represents the relative activity contribution of noble gas radionuclide i to the total noble gas activity for TYPICAL GASEOUS EFFLUENTS (unitless)

This value has been calculated for all gaseous radwaste discharges for the years 1986, 1987, and 1988 in accordancewith equation 3R on Attachment 5.

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 240 of 318 1 Empirical Derivation of Site-Specific Dose Factors BETA-AIR-DOSE FACTOR A site-specific, beta-air-dose factor has been derived from historical data in accordance with the following equation.

Nayg

=

(N) (f)

Eq. 4FF Navg

= the empirically derived, site-specific, beta-air-dose factor due to all noble gases released during a specified time period Values of Navg have been calculated using gaseous radwaste discharge data collected over several years.

The results of the calculations appear in the Table on page 5 of this attachment.

Ni

=

the air dose factor due to beta emissions for each identified noble gas radionuclide, i (mrad/yr per microcurie/cubic meter)

The beta air dose factors have been obtained from Regulatory Guide 1.109, Appendix B, Table B-1.

The beta air dose factors for various noble gas radionuclides are tabulated in Attachment 10 (Attachment 1 of old ODCM).

f.

=

a fraction which represents the relative activity contribution of noble gas radionuclide i to the total noble gas activity for TYPICAL GASEOUS EFFLUENTS (unitless)

This value has been calculated for all gaseous radwaste discharges for the years 1986, 1987, and 1988 in accordance with equation 3R on Attachment 5.

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 241 of 318 1 Empirical Derivation of Site-Specific Dose Factors SITE-SPECIFIC, AVERAGE DOSE FACTORS Year Kavg Lavg Mavg Navg 1986 330 790 390 1100 1987 340 810 400 1100 1988 390 960 450 1200 Average 350 850 410 1100 Maximum % difference 11%

13%

10%

9%

As can be seen from the above table, the percent difference between the yearly dose factors and the 3-year average dose factors range from 9% to 13%. This variability is minor considering other areas of uncertainty inherent in the environmental dose calculation models.

It should be noted that the empirically-derived, site-specific, average dose factors listed in the above table shall only rarely be used. In those rare instances where empirically-derived, site-specific, average dose factors are used, the results shall be carefully evaluated by qualified members of the facility staff to ensure the estimated doses are only a small fraction of the Control limits. Additionally, the doses shall be recalculated using the RIGOROUS METHODS prior to submitting the Radioactive Effluent Release Report.

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 242 of 318 2 Gaseous Effluent Pathway Dose Factors GRASS-COW-MEAT DOSE FACTORS ADULT (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver Thody Thyroid Kidney Lung Gitract H-3 0.OOOE+00 3.250E+02 3.250E+02 3.250E+02 3.250E+02 3.250E+02 3.250E+02 C-14 3.330E+05 6.660E+04 6.660E+04 6.660E+04 6.660E+04 6.660E+04 6.660E+04 NA-24 1.840E-03 1.840E-03 1.840E-03 1.840E-03 1.840E-03 1.840E-03 1.840E-03 P-32 4.650E+09 2.890E+08 1.800E+08 0.000E+00 0.OOOE+00 0.OOOE+00 5.230E+08 CR-51 0.OOOE+00 0.000E+00 7.070E+03 4.220E+03 1.560E+03 9.380E+03 1.780E+06 MN-54 0.000E+00 9.150E+06 1.750E+06 O.OOOE+00 2.720E+06 0.OOOE+00 2.800E+07 MN-56 O.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0o.000E+00 0.OOOE+00 FE-55 2.930E+08 2.020E+08 4.720E+07 O.OOOE+00 0.OOOE+00 1.130E+08 1.160E+08 FE-59 2.670E+08 6.270E+08 2.400E+08 0.OOOE+00 0.OOOE+00 1.750E+08 2.090E+09 CO-57 0.OOOE+00 5.640E+06 9.370E+06 0.000E+00 0.000E+00 O.OOOE+00 1.430E+08 CO-58 0.OOOE+00 1.830E+07 4.100E+07 0.OOOE+00 O.OOOE+00 0.000E+00 3.700E+08 CO-60 0.OOOE+00 7.520E+07 1.660E+08 0.000E+00 0.OOOE+00 0.OOOE+00 1.41 OE+09 NI-63 1.890E+10 1.310E+09 6.330E+08 0.OOOE+00 O.OOOE+00 O.OOOE+00 2.730E+08 NI-65 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 CU-64 0.OOOE+00 2.950E-07 1.390E-07 O.OOOE+00 7.450E-07 0.OOOE+00 2.520E-05 ZN-65 3.560E+08 1.130E+09 5.120E+08 0.OOOE+00 7.570E+08 0.OOOE+00 7.130E+08 ZN-69 O.OOOE+00 O.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-82 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 BR-83 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 BR-84 0.OOOE+00 0.OOOE+00 0,OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 O.OOOE+00 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 RB-86 0.OOOE+00 4.870E+08 2.270E+08 0.OOOE+00 0.000E+00 0.OOOE+00 9.600E+07 RB-88 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 RB-89 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 SR-89 3.010E+08 0.OOOE+00 8.650E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.840E+07 SR-90 1.240E+10 0.000E+00 3.050E+09 0.000E+00 0.000E+00 0.000E+00 3.590E+08 SR-91 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.380E-09 SR-92 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 Y-90 1.070E+02 0.OOOE+00 2.860E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.130E+06 Y-91 M O.OOOE+00 O.OOOE+00 O.OOOE+00 O.000E+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 Y-91 1.130E+06 O.OOOE+00 3.030E+04 O.OOOE+00 O.OOOE+00 O.OOOE+00 6.240E+08 Y-92 O.OOOE+00 O.OOOE+00 O.O00E+00 O.OOOE+00 O.OOE+00 O.000E+00 O.000E+00 Y-93 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 2.080E-07

OFFSITE DOSE CALCULATION MAINUAL Rev.

00802 I

Page 243 of 318 ient Gaseous Effluent Pathway Dose Factors GRASS-COW-MEAT DOSE FACTORS ADULT (m2*mrem/yr per-uCi/sec)

Nuclide Bone Liver Tbody "Thyroid Kidney Lung Gitract ZR-95 1.880E+06 6.040E+05 4.090E+05

. 0.000E+00 9.480E+05 0.OOOE+00 1.910E+09 ZR-97 1.830E-05 3.690E-06 1.690E-06 0.OOOE+00 5.580E-06 0.000E+00 1.140E+00 NB-95 2.290E+06 1.280E+06 6.860E+05 0.OOOE+00 1.260E+06 0.000E+00 7.750E+09 NB-97 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 MO-99 0.OOOE+00 1.090E+05 2.070E+04 0.000E+00 2.460E+05 0.OOOE+00 2.520E+05 TC-99M 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 TC-101 0.000E+00 0.000E+00 0.000E+00 0.O0OE+00 0.000E+00 O.OOOE+00 0.OOOE+00 RU-103 1.060E+08 0.OOOE+00 4.550E+07 0.OOOE+00 4.030E+08 O.000E+00 1.230E+10 RU-105 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 RU-106 2.800E+09 0.000E+00 3.540E+08 0.000E+00 5.400E+09 0.000E+00 1.810E+11 RH-103M 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 RH-106 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 AG-11OM 6.690E+06 6.190E+06 3.670E+06 0.000E+00 1.220E+07 0.000E+00 2.520E+09 SB-122 5.580E+03 5.820E+03 7.050E+04

. 9.250E+02 2.750E+03 1.200E+03 6.930E+05 SB-124 1.980E+09 3.740E+07 7.850E+08 4.800E+06 0.OOOE+00 1.540E+09 5.620E+10 SB-125 1.910E+09 2.130E+07 4.540E+08 1.940E+06 0.000E+00 1.470E+09 2.100E+10 TE-125M 3.590E+08 1.300E+08 4.810E+07 1.080E+08 1.460E+09 0.000E+00 1.430E+09 TE-127M 1.120E+09 3.990E+08 1.360E+08 2.850E+08 4.530E+09 0.000E+00 3.740E+09 TE-127 0.000E+00 0.000E+00 0.000E+00 0.000E+00 1.090E-09 0.000E+00 2.100E-08 TE-129M 1.140E+09 4.270E+08 1.810E+08 3.930E+08 4.770E+09 0.000E+00 5.760E+09 TE-129 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 TE-131M 4.510E+02 2.210E+02 1.840E+02 3.500E+02 2.240E+03 0.000E+00 2.190E+04 TE-131 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 TE-132 1.400E+06 9.070E+05 8.510E+05 1.000E+06 8.730E+06 0.000E+00 4.290E+07 1-130 2.350E-06 6.940E-06 2.740E-06 5.880E-04 1.080E-05 0.000E+00 5.980E-06 1-131 1.080E+07 1.540E+07 8.830E+06 5.050E+09 2.640E+07 0.000E+00 4.070E+06 1-132 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 1-133 4.300E-01 7.470E-01 2.280E-01 1.100E+02 1.300E+00 0.000E+00 6.720E-01 1-134 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 1-135 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 CS-134 6.570E+08 1.560E+09 1.280E+09 0.000E+00 5.060E+08 1.680E+08 2.740E+07 CS-136 1.180E+07 4.670E+07 3.360E+07 0.000E+00 2.600E+07 3.560E+06 5.300E+06 CS-137 8.720E+08 1.190E+09 7.810E+08 0.000E+00 4.050E+08 1.350E+08 2.310E+07 CS-138 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 244 of 318 2 Gaseous Effluent Pathway Dose Factors GRASS-COW-MEAT DOSE FACTORS ADULT (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract BA-139 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 BA-140 2.880E+07 3.610E+04 1.890E+06 O.OOOE+00 1.230E+04 2.070E+04 BA-141 O.OOOE+00 0.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 BA-142 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 LA-140 3.600E-02 1.810E-02 4.790E-03 O.OOOE+00 O.OOOE+00 O.OOOE+00 LA-142 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 CE-141 1.400E+04 9.480E+03 1.080E+03 O.OOOE+00 4.400E+03 O.OOOE+00 CE-143 2.090E-02 1.550E+01 1.710E-03 0.OOOE+00 6.800E-03 O.OOOE+00 CE-144 1.460E+06 6.090E+05 7.830E+04 O.OOOE+00 3.610E+05 O.OOOE+00 PR-143 2.130E+04 8.540E+03 1.060E+03 O.OOOE+00 4.930E+03 O.OOOE+00 PR-144 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 ND-147 7.080E+03 8.180E+03 4.900E+02 O.OOOE+00 4.780E+03 O.OOOE+00 EU-1 54 8.030E+06 9.870E+08 7.020E+05 O.OOOE+00 4.720E+06 O.OOOE+00 EU-155 1.110E+06 1.580E+05 1.020E+05 O.OOOE+00 7.300E+05 O.OOOE+00 W-187 2.160E-02 1.810E-02 6.320E-03 O.OOOE+00 O.OOOE+oo O.OOOE+00 NP-239 2.560E-01 2.510E-02 1.390E-02 O.OOOE+00 7.840E-02 O.OOOE+00 O.OOOE+00 5.920E+07 O.OOOE+00 O.OOOE+00 1.330E+03 0.000E+00 3.620E+07 5.780E+02 4.930E+08 9.330E+07 O.OOOE+00 3.930E+07 7.150E+08 1.240E+08 5.920E+00 5.150E+03

SOFFSITE DOSE CAL CULATION MANUAL

`Rev. 00802 C

MPage 245 of 318 2 Gaseous Effluent Pathway Dose Factors GRASS-COW-MEAT DOSE FACTORS TEEN (m2*mrem/yr per uCi/sec)

Nuclide H-3 C-14 NA-24 P-32 CR-51 MN-54 MN-56 FE-55 FE-59 CO-57 CO-58 CO-60 NI-63 N!-65 CU-64 ZN-65 ZN-69 BR-82 BR-83 BR-84 BR-85 RB-86 RB-88 RB-89 SR-89 SR-90 SR-91 SR-92 Y-90 Y-91 M Y-91 Y-92 Y-93 Bone Liver Tbody Thyroid 0.OOOE+00 1.940E+02 1.940E+02 1.940E+02 2.810E+05 5.620E+04 5.620E+04 5.620E+04 1.470E-03 11.470E-03 1.470E-03 1.470E-03 3.930E+09 2.440E+08 1.520E+08 0.000E+00 0.OOOE+00 0.OOOE+00 5.650E+03 3.140E+03 0.OOOE+00 6.980E+06 1.380E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.380E+08 1.690E+08 3.930E+07 0.OOOE+00 2.130E+08 4.980E+08 1.920E+08 0.OOOE+00 0.OOOE+00-4.530E+06 7.590E+06 0.OOOE+00 0.OOOE+00 1.41 OE+07 3.250E+07 0.OOOE+00 0.OOOE+00 5.830E+07 1.310E+08 0.000E+00 1.520E+10 1.070E+09 5.150E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 2.41 OE-07 1.1 30E-07 0.OOOE+00 2.500E+08 8.690E+08 4.050E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000Et00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.oo0E+00 0.OOOE+00 4.060E+08 1.910E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.540E+08 0.OOOE+00 7.290E+06 0.OOOE+00 8.050E+09 0.OOOE+00 1.990E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 8.980E+01 0.OOOE+00 2.420E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00, 9.560E+05 0.OOOE+00 2.560E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00

  • Kidney Lung 1.940E+02 1.940E+02 5.620E+04 5.620E+04 1.470E-03 1.470E-03 0.OOOE+00 0.OOOE+00

.1,240E+03 8.070E+03 2.080E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.070E+08 0.OOOE+00 1.570E+08 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.100E-07 0.OOOE+00 5.560E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00

.OMOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 Gitract 1.940E+02 5.620E+04 1.470E-03 3.300E+08 9.500E+05 1.430E+07 0.OOOE+00 7.300E+07 1.180E+09 8.450E+07 1.940E+08 7.600E+08 1.710E+08 0.OOOE+00 1.870E-05 3.680E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.01 OE+07 0.OOOE+00 0.OOOE+00 3.030E+07 2.260E+08 1.100E-09 0.OOOE+00 7.400E+05 0.OOOE+00 3.920E+08 0.OOOE+OG 1.690E-07

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 246 of 318 Gaseous Effluent Pathway Dose Factors GRASS-COW-MEAT DOSE FACTORS TEEN (m2*mrem/yr per uCi/sec)

Thody Thyroid Nuclide Bone Liver Kidney Lung Gltract ZR-95 ZR-97 NB-95 NB-97 MO-99 TC-99M TC-101 RU-103 RU-105 RU-106 RH-103M RH-106 AG-I10M SB-122 SB-124 SB-125 TE-125M TE-127M TE-127 TE-129M TE-129 TE-131M TE-131 TE-132 1-130 1-131 1-132 1-133 1-134 1-135 CS-1 34 CS-136 CS-137 CS-138 1.510E+06 4.760E+05 1.530E-05 3.020E-06 1.790E+06 9.940E+05 0.OOOE+00 0.OOOE+00 0.000E+00 8.980E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 8.600E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.360E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.060E+06 4.790E+06 3.300E+03 3.440E+03 1.620E+09 2.980E+07 1.560E+09 1.710E+07 3.030E+08 1.090E+08 9.41 OE+08 3.340E+08 O.OOOE+00 O.OOOE+00 9.580E+08 3.560E+08 0.OOOE+00 0.OOOE+00 3.760E+02 1.800E+02 0.OOOE+00 0.OOOE+00 1.1 50E+06 7.260E+05 1.890E-06 5.480E-06 8.950E+06 1.250E+07 0.000E+00 0.OOOE+00 3.590E-01 6.100E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 5.230E+08 1.230E+09 9.220E+06 3.630E+07 7.240E+08 9.630E+08 0.OOOE+00 0.OOOE+00 3.270E+05 0.OOOE+00 6.990E+05 0.OOOE+00 1.100E+09 1.390E-06 0.OOOE+00 4.580E-06 0.000E+00 8.180E-01 5.470E+05 0.OOOE+00 9.640E+05 0.000E+00 4.250E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.710E+04 0.OOOE+00 2.060E+05 0.OOOE+00 1.610E+05 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.680E+07 0.OOOE+00 3.030E+08 0.OOOE+00 7.180E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 2,970E+08 0.OOOE+00 4.550E+09 0.000E+00 1.130E+11 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.910E+06 0.OOOE+00 9.140E+06 0.OOOE+00 1.350E+09 4.170E+04 5.460E+02 1.620E+03 7.080E+02 4.1OOE+05 6.310E+08 3.670E+06 0.OOOE+00 1.410E+09 3.260E+10 3.660E+08 1.490E+06 O.OOOE+00 1.370E+09 1.220E+10 4.050E+07 8.470E+07 O.OOOE+00 O.OOOE+00 8.940E+08 1.120E+08 2.240E+08 3.820E+09 O.000E+00 2.350E+09 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.750E-08 1.520E+08 3.090E+08 4.010E+09 O.000E+00 3.600E+09 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.000E+00 O.OOOE+00 1.500E+02 2.71 OE+02 1.880E+03 O.OOOE+00 1.450E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.840E+05 7.660E+05 6.970E+06 0.OOOE+00 2.300E+07 2.190E-06 4.470E-04 8.440E-06 0.OOOE+00 4.21 OE-06 6.730E+06 3.660E+09 2.160E+07 0.OOOE+00 2.480E+06 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.860E-01 8.510E+01 1.070E+00 0.OOOE+00 4.610E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 O.OOOE+O0 O.OOOE+00 O.OOOE+00 O.OOOE+00 5.71 OE+08 O.OOOE+00 3.91 OE+08 1.490E+08 1.530E+07 2.440E+07 0.O00E+00 1.970E+07 3.110E+06 2.920E+06 3.360E+08 O.OOOE+00 3.280E+08 1.270E+08 1.370E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00

OFFSITIE DOSE, CALCULATION MANUAL Rev.

00802 DO CI MPage 247 of 318 2 Gaseous Effluent Pathway Dose Factors GRASS-COW-MEAT DOSE FACTORS TEEN (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract' BA-139 BA-140 BA-141 BA-142 LA-140 LA-142 CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 EU-154 EU-155 W-187 NP-239 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 2.380E+07 2.910E+04 1.530E+06 0.OOOE+00 9,880E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 2.960E-02 1.450E-02 3.870E-03 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.180E+04 7.860E+03 9.030E+02 0.OOOE+00 3.700E+03 1.760E-02 1.280E+01 1.430E-03 0.OOOE+00 5.740E-03 1.230E+06 5.080E+05 6.600E+04 0.OOOE+00 3.040E+05 1.790E+04 7.150E+03 8.920E+02 0.OOOE+00 4.160E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.240E+03 6.790E+03 4.060E+02 0.OOOE+00 3.980E+03 6.090E+06 7.870E+05 5.540E+05 0.OOOE+00 3.520E+06 1.330E+06 1.290E+05 7.970E+04 0.OOOE+00 5:030E+05 1.810E-02 1.480E-02 5.170E-03 0.000E+00 0.OOOE+00 2.230E-01 2.11OE-02

.1.170E-02 O.OOOE+00 6.610E-02 0.OOOE+00 0.OOOE+00 1.960E+04 3.670E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 01.OOOE+00.

8.350E+02 0.OOOE+00 0.OOOE+00 0.00OE+00 2.250E+07 0.OOOE+00 3.850E+02 0.OOOE+00 3.090E+08 0.OOOE+00 5.900E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.450E+07 0.OOOE+00 4.160E+08 0.OOOE+00 7.380E+08 0.OOOE+00 3.990E+00 O.OOOE+00 3.390E+'03

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 248 of 318 Gaseous Effluent Pathway Dose Factors GRASS-COW-MEAT DOSE FACTORS CHILD (m2*mrem/yr per uCi/sec) r Thody Thyroid Kid Nuclide Bone Live ney Lung Gitract H-3 C-14 NA-24 P-32 CR-51 MN-54 MN-56 FE-55 FE-59 CO-57 CO-58 CO-60 NI-63 NI-65 CU-64 ZN-65 ZN-69 BR-82 BR-83 BR-84 BR-85 RB-86 RB-88 RB-89 SR-89 SR-90 SR-91 SR-92 Y-90 Y-91 M Y-91 Y-92 Y-93 O.OOOE+00 5.290E+05 2.340E-03 7.410E+09 O.OOOE+00 0.OOOE+00 0.OOOE+00 4.570E+08 3.780E+08 O.OOOE+00 O.000E+00 O.O00E+00 2.910E+10 O.OOOE+00 0.000E+00 3.750E+08 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 4.820E+08 1.040E+10 0.000E+00 0.000E+00 1.700E+02 0.OOOE+00 1.810E+06 O.OOOE+00 0.OOOE+00 2.340E+02 2.340E+02 2.340E+02 2.340E+02 1.060E+05 1.060E+05 1.060E+05 1.060E+05 2.340E-03 2.340E-03 2.340E-03 2.340E-03 3.470E+08 2.860E+08 0.000E+00 0.000E+00 0.OOOE+00 8.810E+03 4.890E+03 1.340E+03 7.990E+06 2,130E+06 0.OOOE+00 2.240E+06 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 2.420E+08 7.510E+07 0.OOOE+00 0.000E+00 6.120E+08 3.050E+08 0.000E+00 0.000E+00 5.920E+06 1.200E+07 0.000E+00 0.OOOE+00 1.650E+07 5.040E+07 0.OOOE+00 0.000E+00 6.930E+07 2.040E+08 0.000E+00 0.OOOE+00 1.560E+09 9.910E+08 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 3.240E-07 1.960E-07 0.OOOE+00 7.820E-07 1.OOOE+09 6.220E+08 0.OOOE+00 6.300E+08 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 O.000E+00 O.000E+00 O.OOOE+00 O.002E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 5.760E+08 3.540E+08 0.OOOE+00 0.OOOE+00 O.002E+00 O.002E+00 O.OOOE+00 O.000E+00 O.O00E+00 O.OOOE+00 O.OOOE+00 O.O00E+00 O.OOOE+00 1.380E+07 O.O00E+00 O.000E+00 O.OOOE+00 2.640E+09 O.O00E+00 O.O00E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.550E+00 0.OOOE+00 0.OOOE+00 0.O00E+00 O.OOOE+00 O.OOOE+00 O.O00E+00 O.000E+00 4.830E+04 O.O00E+00 O.000E+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 2.340E+02 2.340E+02 1.060E+05 1.060E+05 2.340E-03 2.340E-03 0.000E+00 2.050E+08 8.930E+03 4.670E+05 0.OOOE+00 6.700E+06 0.000E+00 0.OOOE+00 1.370E+08 4.490E+07 1.770E+08 6.370E+08 0.000E+00 4.850E+07 0.000E+00 9.600E+07 0.OOOE+00 3.840E+08 0.OOOE+00 1.050E+08 O.OOOE+00 O.002E+00 O.OOOE+00 1.520E-05 0.000E+00 1.760E+08 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 O.OOOE+00 O.000E+00 0.000E+00 0.000E+00 0.OOOE+00 3.71 OE+07 0.000E+00 0.OOOE+00 O.OOOE+O0 O.000E+00 0.OOOE+00 1.860E+07 0.000E+00 1.400E+08 0.000E+00 1.010E-09 0.000E+00 0.000E+00 0.000E+00 4.840E+05 0.000E+00 0.000E+00 0.000E+00 2.410E+08 0.000E+00 0.000E+00 0.000E+00 1.550E-07

Rev.

00802 OFFSITE DOSE CALCULATION MANUAL PagRe 2

.Page 249 of 318 knt 12 Gaseous Effluent Pathway Dose Factors GRASS-COW-MEAT DOSE FACTORS Nuclide ZR-95 ZR-97 NB-95 NB-97 MO-99 TC-99M TC-101 RU-103 RU-105 RU-106 RH-103M RH- 06 AG-1 10M SB-122 SB-124 SB-125 TE-125M TE-127M TE-127 TE-129M TE-129 TE-131M TE-131 TE-132 1-130 1-131 1-132 I-133 1-134 I-135 CS-134 CS-1 36 CS-1 37 CS-138 Bone Liver 2.680E+06 5.890E+05 2.840E-05 4.100E-06 3.090E+06 1.200E+06 0.000E+00 0.OOOE+00 0.000E+00 1.250E+05 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 1.560E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.440E+09 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 8.400E+06 5.670E+06 2.080E+03 2.170E+03 2.930E+09 3.800E+07 2.850E+09 2.190E+07 5.690E+08 1.540E+08 1.770E+09 4.780E+08 0.OOOE+00

'0.000E+00 1.810E+09 5.040E+08 0.OOOE+00 O.OOOE+00 7.000E+02 2.420E+02 0.OOOE+00 0.0OOE+00 2.090E+06 9.270E+05 3.390E-06 6.850E-06 1.660E+07 1.670E+07 0.OOOE+00 0.OOOE+00 6.680E-01 8.260E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 9.220E+08 1.510E+09 1.590E+07 4.370E+07 1.330E+09 1.280E+09 0.OOOE+00 0.OOOE+00 CHILD (m2*mrem/yr per uCi/sec)

Tbody Thyroid Kidney 5.240E+05 0.OOOE+00 8.430E+05 2420E-06 0.OOOE+00 5.890E-06 8.61OE+05 0.OOOE+00 1.130E+06 0.OOOE+00 0.000E+00 0.OOOE+00 3.090E+04 0.OOOE+00 2.670E+05 0.OOOE+00 0:OOOE+00 0.OOOE+00 6.006E+00 0.000E+00 0.OOOE+00 5.980E+07 0.OOOE+00 3.920E+08 0.OOOE+00 0.000E+00 0.OOOE+00 5.540E+08 0.OOOE+00 5.990E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.530E+06 0.000E+00 1.060E+07 2.630E+04 3.450E+02 1.020E+03 1.030E+09 6.460E+06 0.OOOE+00 5.960E+08 2.640E+06 0.OOOE+00 7.590E+07 1.600E+08 0.OOOE+00 2.110E+08 4.240E+08 5.060E+09 0.OOOE+00 0.000E+00 1.210E-09 2.800E+08 5.820E+08 5.300E+09 0.OOOE+00 0.000E+00 0.OOOE+00 2.580E+02 4.980E+02 2.340E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.120E+06 1.350E+06 8.600E+06 3.530E-06 7.540E-04 1.020E-05 9.490E+06 5.520E+09 2.740E+07 0.OOOE+00 0.000E+00 0.OOOE+00 3.120E-01 1.530E+02 1.380E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.190E+08 0.OOOE+00 4.690E+08 2.830E+07 0.OOOE+00 2.330E+07 1.880E+08 0.OOOE+00 4.160E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 Lung GItract 0.OOOE+00 6.140E+08 0.OOOE+00 6.210E-01 0.OOOE+00 2.230E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.030E+05 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 4.020E+09 0.000E+00 0.OOOE+00 O.OOOE+00 6.900E+10 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.750E+08 4.460E+02 2.580E+05 1.620E+09 1.830E+10 1.590E+09 6.800E+09 0.000E+00 5.490E+08 0.OOOE+00 1.440E+09 0.OOOE+00 1.660E-08 0.OOOE+00 2.200E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.820E+03 0.OOOE+00 0.000E+00 0.OOOE+00 9.330E+06 0.OOOE+00 3.200E-06 0.OOOE+00 1.490E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.330E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.680E+08 8.150E+06 3.470E+06 1.540E+06 1.500E+08 7.990E+06 0.OOOE+00 0.OOOE+00

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 250 of 318

  • nt Gaseous Effluent Pathway Dose Factors GRASS-COW-MEAT DOSE FACTORS CHILD (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver Thody Thyroid Kidney Lung Gitract BA-139 BA-140 BA-141 BA-142 LA-140 LA-142 CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 EU-154 EU-155 W-187 NP-239 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 4.390E+07 3.850E+04 2.560E+06 O.OOOE+00 1.250E+04 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+O0 O.OOOE+O0 O.OOOE+O0 O.OOOE+O0 O.OOOE+O0 5.410E-02 1.890E-02 6.380E-03 O.OOOE+O0 O.OOOE+O0 O.OOOE+O0 O.OOOE+O0 O.OOOE+O0 O.OOOE+O0 O.OOOE+O0 2.220E+04 1.11OE+04 1.640E+03 O.OOOE+O0 4.840E+03 3.300E-02 1.790E+01 2.590E-03 O.OOOE+00 7.51 OE-03 2.320E+06 7.260E+05 1.240E+05 O.OOOE+00 4.020E+05 3.390E+04 1.020E+04 1.680E+03 O.OOOE+00 5.51 OE+03 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00

1. 170E+04 9.480E+03 7.340E+02 O.OOOE+00 5.200E+03 1.120E+07 1.010E+06 9.190E+05 O.OOOE+00 4.420E+06 2.330E+06 1.680E+05 1.310E+05 O.OOOE+00 6.280E+05 3.360E-02 1.990E-02 8.920E-03 O.OOOE+00 O.OOOE+00 4.200E-01 3.020E-02 2.120E-02 O.OOOE+00 8.730E-02 O.OOOE+00 O.OOOE+00 2.290E+04 2.220E+07 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 5.270E+02 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.380E+07 O.OOOE+00 2.620E+02 O.OOOE+00 1.890E+08 O.OOOE+00 3.660E+07 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.500E+07 O.OOOE+00 2.340E+08 O.OOOE+00 4.200E+08 O.OOOE+00 2.790E+00 O.OOOE+00 2.230E+03 It

S OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 251 of 318 2 7

Gaseous Effluent Pathway Dose Factors GRASS-COW-MEAT DOSE FACTORS INFANT (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract THIS PATHWAY IS NOT APPLICABLE TABLE INTENTIONALLY LEFT BLANK

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 252 of 318 I

Gaseous Effluent Pathway Dose Factors VEGETATION DOSE FACTORS ADULT (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver Thody Thyroid Kidney Lung Gitract H-3 0.OOOE+00 2.260E+03 2.260E+03 2.260E+03 2.260E+03 2.260E+03 2.260E+03 C-14 8.970E+05 1.790E+05 1.790E+05 1.790E+05 1.790E+05 1.790E+05 1.790E+05 NA-24 2.760E+05 2.760E+05 2.760E+05 2.760E+05 2.760E+05 2.760E+05 2.760E+05 P-32 1.400E+09 8.730E+07 5.420E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.580E+08 CR-51 0.OOOE+00 0.OOOE+00 4.660E+04 2.790E+04 1.030E+04 6.190E+04 1.170E+07 MN-54 0.OOOE+00 3.110E+08 5.940E+07 0.OOOE+00 9.270E+07 O.OOOE+00 9.540E+08 MN-56 0.OOOE+00 1.610E+01 2.850E+00 0.OOOE+00 2.040E+01 0.OOOE+00 5.130E+02 FE-55 2.090E+08 1.450E+08 3.370E+07 0.OOOE+00 0.OOOE+00 8.060E+07 8.290E+07 FE-59 1.270E+08 2.990E+08 1.140E+08 0.OOOE+00 0.OOOE+00 8.350E+07 9.960E+08 CO-57 0.OOOE+00 1.170E+07 1.950E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.970E+08 CO-58 0.OOOE+00 3.090E+07 6.920E+07 0.OOOE+00 O.OOOE+00 0.OOOE+00 6.260E+08 CO-60 O.OOOE+00 1.670E+08 3.690E+08 0.OOOE+00 O.OOOE+00 0.OOOE+00 3.140E+09 NI-63 1.040E+10 7.210E+08 3.490E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.500E+08 NI-65 6.150E+01 7.990E+00 3.650E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.030E+02 CU-64 0.OOOE+00 9.270E+03 4.350E+03 0.OOOE+00 2.340E+04 0.OOOE+00 7.900E+05 ZN-65 3.170E+08 1.010E+09 4.560E+08 0.OOOE+00 6.750E+08 0.OOOE+00 6.360E+08 ZN-69 8.750E-06 1.670E-05 1.160E-06 0.OOOE+00 1.090E-05 0.OOOE+00 2.510E-06 BR-82 0.OOOE+00 0.OOOE+00 1.510E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.730E+06 BR-83 0.OOOE+00 0.OOOE+00 3.210E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.630E+00 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 RB-86 0.OOOE+00 2.190E+08 1.020E+08 0.OOOE+00 O.OOOE+00 0.OOOE+00 4.320E+07 RB-88 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 RB-89 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 SR-89 9.960E+09 0.OOOE+00 2.860E+08 0.OOOE+00 O.OOOE+00 0.OOOE+00 1.600E+09 SR-90 6.050E+11 0.OOOE+00 1.480E+11 0.OOOE+00 O.OOOE+00 0.OOOE+00 1.750E+10 SR-91 3.200E+05 0.OOOE+00 1.290E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.520E+06 SR-92 4.270E+02 0.OOOE+00 1.850E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 8.460E+03 Y-90 1.330E+04 0.OOOE+00 3.560E+02 0.OOOE+00 O.OOOE+00 0.OOOE+00 1.410E+08 Y-91M 5.830E-09 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.710E-08 Y-91 5.130E+06 O.OOOE+00 1.370E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.820E+09 Y-92 9.010E-01 O.OOOE+00 2.630E-02 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.580E+04 Y-93 1.740E+02 O.OOOE+00 4.800E+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 5.520E+06 I

c

.* Rev.

00802 OFFSITE DOSE CALCULATION MANUAL

-Page 253 of 318 2 Gaseous Effluent Pathway Dose Factors VEGETATION DOSE FACTORS ADULT Nuclide ZR-95 ZR-97 NB-95 NB-97 MO-99 TC-99M TC-101 RU-103 RU-105 RU-106 RH-103M RH-106 AG-110M SB-122 SB-124 SB-125 TE-125M TE-127M TE-127 TE-129M TE-129 TE-131M TE-131 TE-132 I-130 1-131 1-132 1-133 1-134 I-135 CS-134 CS-136 CS-137 CS-1 38 Bone Liver 1.190E+06 3.810E+05 3.330E+02 6.730E+01 1.420E+05 7.910E+04 2.900E-06 7.340E-07 0.OOOE+00 6.250E+06 3.060E+00 8.660E+00 0.OOOE+00 0.OOOE+00 4.800E+06 0.OOOE+00 5.390E+01 0.OOOE+00 1.930E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 1.060E+07 9.760E+06 7.500E+05 7.820E+05 1.040E+08 1.960E+06 1.360E+08 1.520E+06 9.660E+07 3.500E+07 3.490E+08 1.250E+08 5.760E+03 2.070E+03 2.550E+08 9.500E+07 6.650E-04 2.500E-04 9.120E+05 4.460E+05 0.OOOE+00 0.000E+00 4.290E+06 2.770E+06 3.960E+05 1.170E+06 8.090E+07 1.160E+08

,5.740E+01 1.540E+02 2.120E+06 3.690E+06 1.060E-04 2.880E-04 4.080E+04 1.070E+05 4.660E+09 1.110E+10 4.200E+07 1.660E+08 6.360E+09 8.700E+09 0.OOOE+00 0.OOOE+00 (m2*mrem/yr per uCi/sec)

Tbody Thyroid Kidney 2.580E+05 0.OOOE+00 5.970E+05 3.080E+01 0.OOOE+00 1.020E+02 4.250E+04 0.OOOE+00 7.81OE+04 2:680E-07 0.OOOE+00 8.560E-07

,1.190E+06 0.OOOE+00 1.410E+07 1.100E+02 0.OOOE+00 1.320E+02 0.OOOE+00 0.000E+00 0.OOOE+00 2.070E+06 0.OOOE+00 1.830E+07 2.130E+01 0.OOOE+00 6.960E+02 2.440E+07 0.OOOE+00 3.720E+08 0.OOOE+00 0.OOOE+00 0.0OOE+00 0.O0E+00 0.OOOE+00 0.000E+00 5.800E+06 0.OOOE+00 1 920E+07 9.470E+06 1.240E+05 3.690E+05 4.11OE+07 2.520E+05 0.000E+00 3.250E+07 i1.390E+05 0.OOOE+00 1.290E+07 2.900E+07 3.930E+08 4.260E+07 8.920E+07 1.420E+09 1.250E+03 4.270E+03 2.350E+04 4.030E+07 8.750E+07 1.060E+09 1.620E-04 5.100E-04 2.790E-03 3.720E+05 7.060E+05 4.520E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.600E+06 3.060E+06 2.670E+07 4.610E+05 9.900E+07 1.820E+06 6.630E+07 3.790E+10 1.980E+08 5.380E+01 5.380E+03 2.450E+02 1.120E+06 5.420E+08 6.440E+06 1.030E-04 5.OOOE-03 4.590E-04 3.940E+04 7.040E+06 1.710E+05

.9.070E+09 0.OOOE+00 3.590E+09 1.190E+08 0.000E+00 9.240E+07 5.700E+09 0.OOOE+00 2.950E+09 0.000E+00 0.OOOE+00 0.OOOE+00 Lung Gitract 0.OOOE+00 1.21 OE+09 0.OOOE+00 2.080E+07 0.OOOE+00 4.800E+08 0.OOOE+00 2.710E-03 0.OOOE+00 1.450E+07 4.240E+00 5.120E+03 0.OOOE+00 0.OOOE+00 0.000E+00 5.61 OE+08 O.OOOE+00 3.300E+04 O.OOOE+00 1.250E+10 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 3.980E+09 1.610E+05 9.320E+07 8.080E+07 2.950E+09 1.050E+08 1.500E+09 0.000E+00 3.860E+08 0.OOOE+00 1.170E+09 0.OOOE+00 4.540E+05 0.OOOE+00 1.280E+09 0.OOOE+00 5.020E-04 0.OOOE+00 4.430E+07 0.OOOE+00 0,000E+00 0.OOOE+00 1.310E+08 0.OOOE+00 1.010E+06 O.OOOE+00 3.050E+07 0.OOOE+00 2.890E+01 0.OOOE+00 3.31 OE+06 0.OOOE+00 2.51 0E-07 0.OOOE+00 1.21 OE+05 1.190E+09 1.940E+08 1 i.270E+07 1.890E+07 9.810E+08 1.680E+08 0.OOOE+00 0.OOOE+00

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 254 of 318 2 Gaseous Effluent Pathway Dose Factors VEGETATION DOSE FACTORS ADULT (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver Thody Thyroid Kidney Lung Gitract BA-139 2.950E-02 2.1OOE-05 8.640E-04 0.OOOE+00 1.960E-05 1.190E-05 5.230E-02 BA-140 1.290E+08 1.620E+05 8.430E+06 0.OOOE+00 5.490E+04 9.250E+04 2.650E+08 BA-141 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 0.OOOE+00 BA-142 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 0.OOOE+00 LA-140 1.970E+03 9.920E+02 2.620E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.280E+07 LA-142 1.400E-04 6.350E-05 1.580E-05 0.OOOE+00 O.OOOE+00 0.OOOE+00 4.640E-01 CE-141 1.960E+05 1.330E+05 1.510E+04 O.OOOE+00 6.170E+04 0.OOOE+00 5.080E+08 CE-143 1.000E+03 7.420E+05 8.210E+01 0.OOOE+00 3.260E+02 0.OOOE+00 2.770E+07 CE-144 3.290E+07 1.380E+07 1.770E+06 0.OOOE+00 8.160E+06 0.OOOE+00 1.110E+10 PR-143 6.340E+04 2.540E+04 3.140E+03 0.OOOE+00 1.470E+04 0.OOOE+00 2.780E+08 PR-144 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 ND-147 3.340E+04 3.860E+04 2.310E+03 0.OOOE+00 2.250E+04 0.OOOE+00 1.850E+08 EU-154 4.850E+07 5.970E+06 4.250E+06 0.000E+00 2.860E+07 0.OOOE+00 4.320E+09 EU-155 6.710E+06 9.510E+05 6.140E+05 0.OOOE+00 4,390E+06 0.OOOE+00 7.490E+08 W-187 3.820E+04 3.190E+04 1.120E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.050E+07 NP-239 1.420E+03 1.400E+02 7.720E+01 0.OOOE+00 4.370E+02 0.OOOE+00 2.870E+07

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 255 of 318, iment Gaseous Effluent Pathway Dose Factors VEGETATION DOSE FACTORS TEEN (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver I.

I Tbody Thyroid Kidney Lung Gitract H-3 C-14 NA-24 P-32 CR-51 MN-54 MN-56 FE-55 FE-59 CO-57 CO-58 CO-60 NI-63 NI-65 CU-64 ZN-65 ZN-69 BR-82 BR-83 BR-84 BR-85 RB-86 RB-88 RB-89 SR-89 SR-90 SR-91 SR-92 Y-90 Y-91M Y-91 Y-92 Y-93, 0.060E+00 2.590E+03 2.590E+03 1.450E+06 2.910E+05

,2.910E+05 2.450E+b5 2.450E+05 2.450E+05 1.610E+09 9.960E+07 6.230E+07 0.OOOE+00 0.OOOE+00

.6.200E+04 0.OOOE+00 4.520E+08 8.970E+07 0.OOOE+00 1.450E+01 2.580E+00 3.250E+08 2.31 OE+08 5.380E+07 1.810OE+08 4.220E+08 1.630E+08 0.OOOE+00 1.790E+07 3.OOOE+07 0.OOOE+00 4.380E+07 1.010E+08 0.OOOE+00 2.490E+08 5;600E+08 1.610E+10 1.130E+09 5.450E+08 5.730E+01 7.320E+00 3.330E+00 0.OOOE+00 8.400E+03 3.950E+03 4.240E+08 1.470E+09 6.860E+08 8.190E-06 1.560Eý-05 1.090E-06 0.OOOE+00 0.OOOE+00 1.330E+06 0.OOOE+00 0.OOOE+00 3.010E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.730E+08 1.280E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.510E+10 0.OOOE+00 4.330E+08 7.51 0E+1 1 0.OOOE+00 1.850E+1 1 2.990E+05 0.OOOE+00 1.190E+04 3.970E+02 0.OOOE+00 1.690E+01 1.240E+04 0.OOOE+00 3.340E+02 5.430E-09 0.OOOE+00 0.OOOE+00 7.870E+06 0.OOOE+00 2.11 OE+05 8.470E-01 0.OOOE+00 2.450E-02 1.630E+02 0.OOOE+00 4.470E+00 2.590E+03 2.590E+03 2.91 OE+05 2.91 OE+05 2.450E+05 2.450E+05 0.OOOE+00 0.OOOE+00 3.440E+04

.1.360E+04 0.OOOE+00 1.350E+08 0.OOOE+00 1.830E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.120E+04 c3.OOOE+00 9.41 OE+08 0.OOOE+00 1.020E-05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00.

0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+0O 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+O0 O.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 2.590E+03 2.590E+03 2.91 OE+05 2.91 OE+05 2.450E+05 2.450E+05 0.OOOE+00 1.350E+08 8.850E+04 1.040E+07 0.OOOE+O0 9.270E+08 0.OOOE+00 9;540E+02 1.460E+08 9.980E+07 1.330E+08 9M98E+08 0.OOOE+00 3.340E+08 0.OOOE+00 6.040E+08 0.OOOE+00 3.240E+09 0.OOOE+00 1.81 OE+08 0.OOOE+00

.3.970E+02 0.OOOE+00 6.510E+05 0.OOOE+00 6.230E+08 0.OOOE+/-00 2.880E-05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.050E+07 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.800E+09 0.OOOE+00 2.110E+10 0.OOOE+00 1.360E+06 0.OOOE+00 1.010OE+04 0.OOOE+00 1.020E+08 0.OOOE+00 2.560E-07 0.OOOE+00 3.230E+09 0.OOOE+00 2.320E+04 0.OOOE+00 4.980E+06

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 256 of 318 Gaseous Effluent Pathway Dose Factors VEGETATION DOSE FACTORS TEEN (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver Thody Thyroid Kidney Lung Gltract ZR-95 1.740E+06 5.490E+05 3.780E+05 0.000E+00 8.070E+05 0.000E+00 1.270E+09 ZR-97 3.090E+02 6.110E+01 2.810E+01 O.000E+00 9.260E+01 0.000E+00 1.650E+07 NB-95 1.920E+05 1.060E+05 5.860E+04 0.000E+00 1.030E+05 0.000E+00 4.550E+08 NB-97 2.690E-06 6.670E-07 2.440E-07 0.000E+00 7.800E-07 0.000E+00 1.590E-02 MO-99 0.000E+00 5.740E+06 1.090E+06 0.000E+00 1.310E+07 0.000E+00 1.030E+07 TC-99M 2.700E+00 7.540E+00 9.770E+01 0.OOOE+00 1.120E+02 4.190E+00 4.950E+03 TC-101 0.000E+00 O.000E+00 0.000E+00 0.000E+00 O.000E+00 O.000E+00 0.000E+00 RU-103 6.870E+06 0.OOOE+00 2.940E+06 0.000E+00 2.420E+07 0.000E+00 5.740E+08 RU-105 5.OOOE+01 0.OOOE+00 1.940E+01 0.000E+00 6.310E+02 0.OOOE+00 4.040E+04 RU-106 3.090E+08 0.000E+00 3.900E+07 0.000E+00 5.970E+08 0.000E+00 1.480E+10 RH-103M 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 RH-106 0.OOOE+00 0.000E+00 0.000E+00 0OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 AG-110M 1.520E+07 1.440E+07 8.740E+06 0.000E+00 2.740E+07 0.000E+00 4.040E+09 SB-122 4.920E+05 5.130E+05 6.220E+06 8.150E+04 2.420E+05 1.060E+05 6.120E+07 SB-124 1.550E+08 2.850E+06 6.030E+07 3.51OE+05 0.OOOE+00 1.350E+08 3.110E+09 SB-125 2.140E+08 2.340E+06 5.OOOE+07 2.040E+05 0.000E+00 1.880E+08 1.660E+09 TE-125M 1.480E+08 5.340E+07 1.980E+07 4.140E+07 0.OOOE+00 0.000E+00 4.370E+08 TE-127M 5.510E+08 1.960E+08 6.560E+07 1.310E+08 2.240E+09 0.000E+00 1.370E+09 TE-127 5.430E+03 1.920E+03 1.170E+03 3.740E+03 2.200E+04 0.OOOE+00 4.190E+05 TE-129M 3.670E+08 1.360E+08 5.810E+07 1li80E+08 1.540E+09 0.OOOE+00 1.380E+09 TE-129 6.220E-04 2.320E-04 1.510E-04 4.450E-04 2.61 OE-03 0,OOOE+00 3.400E-03 TE-131M 8.440E+05 4.050E+05 3.380E+05 6.090E+05 4.220E+06 0.OOOE+00 3.250E+07 TE-131 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 TE-132 3.900E+06 2.470E+06 2.320E+06 2.600E+06 2.370E+07 0.OOOE+00 7.820E+07 1-130 3.540E+05 1.020E+06 4.090E+05 8.350E+07 1.580E+06 0.OOOE+00 7.870E+05 1-131 7.700E+07 1.080E+08 5.790E+07 3.140E+10 1,850E+08 0.OOOE+00 2.130E+07 1-132 5.180E+01 1.360E+02 4.870E+01 4.570E+03 2.140E+02 0.OOOE+00 5.910E+01 1-133 1.970E+06 3.340E+06 1.020E+06 4.660E+08 5.860E+06 0.OOOE+00 2.530E+06 1-134 9.590E-05 2.540E-04 9.130E-05 4.240E-03 4.010E-04 0.000E+00 3.350E-06 1-135 3.680E+04 9.480E+04 3.520E+04 6.1OOE+06 1.500E+05 0.000E+00 1.050E+05 CS-1 34 7.090E+09 1.670E+10 7.740E+09 0.000E+00 5.300E+09 2.020E+09 2.080E+08 CS-136 4.290E+07 1.690E+08 1.130E+08 0.OOOE+00 9.190E+07 1.450E+07 1.360E+07 CS-137 1.010E+10 1.350E+10 4.690E+09 0.OOOE+00 4,590E+09 1.780E+09 1.920E+08 CS-138 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 257 of 318 Gaseous Effluent Pathway Dose Factors VEGETATION DOSE FACTORS TEEN (m2*mrem/yr per uCi/sec)

Tbody Thyroid Nuclide Bone Liver Kidney BA-139 BA-140 BA-141 BA-142 LA-140 LA-142 CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 EU-1 54 EU-1 55 W-187 NP-239 2.770E-02 1.950E-05 8.080E-04 0.OOOE+00 1.840E-05 1.380E+08 1.690E+05 8.910E+06 0.OOOE+00 5.750E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.800E+03 8.840E+02 2.350E+02 O.OOOE+00 0.OOOE+00 1.280E-04 5.690E-05 1.420E-05 0.OOOE+00 0.000E+00 2.820E+05 1.880E+05 2.160E+04 0.OOOE+00 8.860E+04 9.370E+02 6.820E+05 7.620E+01 0.OOOE+00 3.060E+02 5.270E+07 2.180E+07 2.830E+06 0.OOOE+00 1.300E+07 7.120E+04 2.840E+04 3.550E+03 0.OOOE+00 1.650E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.630E+04 3.940E+04 2.360E+03 0.OOOE+00 2.320E+04 7.060E+07 9.120E+06 6.430E+06 0.OOOE+00 4.080E+07 1.540E+07 1.480E+06 9.190E+05 0.OOOE+00 5.800E+06 3.550E+04 2.900E+04 1.020E+04 0.OOOE+00 0.OOOE+00 1.380E+03 1.300E+02 7.240E+01 0.OOOE+00 4.090E+02 Lung Gitract 1.340E-05 2.470E-01 1.140E+05 2.130E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.080E+07 0.OOOE+00 1.730E+00 0.OOOE+00 5.380E+08 0.OOOE+00 2.050E+07 0.OOOE+00 1.330E+10 0.OOOE+00 2.340E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.420E+08 0.OOOE+00 4.820E+09 0.OOOE+00 8.51 OE+09 0.OOOE+00 7.840E+06 0.OOOE+0o 2.1OOE+07

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 258 of 318 2 Gaseous Effluent Pathway Dose Factors VEGETATION DOSE FACTORS CHILD (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver Thody Thyroid Kidney Lung Gitract H-3 0.OOOE+00 4.010E+03 4.010E+03 4.010E+03 4.010E+03 4.o010E+03 4.010E+03 C-14 3.500E+06 7.010E+05 7.010E+05 7.010E+05 7.010E+05 7.010E+05 7.010E+05 NA-24 3.830E+05 3.830E+05 3.830E+05 3.830E+05 3.830E+05 3.830E+05 3.830E+05 P-32 3.370E+09 1.580E+08 1.300E+08 O.OOOE+00 O.OOOE+00 O.OOOE+00 9.300E+07 CR-51 O.OOOE+00 O.OOOE+00 1.180E+05 6.540E+04 1.790E+04 1.190E+05 6.250E+06 MN-54 O.OOOE+00 6.61 OE+08 1.760E+08 O.OOOE+00 1.850E+08 O.OOOE+00 5.550E+08 MN-56 O.OOOE+00 1.900E+01 4.280E+00 O.OOOE+00 2.290E+01 O.OOOE+00 2.750E+03 FE-55 8.OOOE+08 4.240E+08 1.310E+08 O.OOOE+00 O.OOOE+00 2.400E+08 7.860E+07 FE-59 4.010E+08 6.490E+08 3.230E+08 O.OOOE+00 O.OOOE+00 1.880E+08 6.760E+08 CO-57 O.OOOE+00 2.990E+07 6.040E+07 O.OOOE+00 O.OOOE+OG O.OOOE+00 2.450E+08 CO-58 O.OOOE+00 6.470E+07 1.980E+08 O.OOOE+00 0.OOOE+00 O.OOOE+00 3.770E+08 CO-60 0.OOOE+00 3.780E+08 1.120E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.100E+09 NI-63 3.950E+10 2.11OE+09 1.340E+09 O.OOOE+00 0.OOOE+00 0.OOOE+00 1.420E+08 NI-65 1.050E+02 9.890E+00 5.770E+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 1.210E+03 CU-64 0.OOOE+00 1.11OE+04 6.690E+03 0.OOOE+00 2.680E+04 0.OOOE+00 5.200E+05 ZN-65 8.120E+08 2.160E+09 1.350E+09 0.OOOE+00 1.360E+09 0.OOOE+00 3.800E+08 ZN-69 1.510E-05 2.180E-05 2.020E-06 0.OOOE+00 1.320E-05 0.OOOE+00 1.380E-03 BR-82 0.OOOE+00 0.OOOE+00 2.040E+06 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 BR-83 0.OOOE+00 0.OOOE+00 5.550E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-84 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0o000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-86 0.OOOE+00 4.520E+08 2.780E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.910E+07 RB-88 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-89 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 SR-89 3.590E+10 O.OOOE+00 1.030E+09 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.390E+09 SR-90 1.240E+12 O.OOOE+00 3.150E+11 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.670E+10 SR-91 5.500E+05 O.OOOE+00 2.080E+04 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.210E+06 SR-92 7.280E+02 O.OOOE+00 2.920E+01 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.380E+04 Y-90 2.300E+04 O.OOOE+00 6.170E+02 O.OOOE+00 O.OOOE+00 O.OOOE+00 6.560E+07 Y-91 M 9.940E-09 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.950E-05 Y-91 1.870E+07 O.OOOE+00 5.01 OE+05 O.OOOE+00 O.OOOE+00 O.OOOE+00 2.490E+09 Y-92 1.560E+00 O.OOOE+00 4.460E-02 O.OOOE+00 O.OOOE+00 O.OOOE+00 4.510E+04 Y-93 3.01 OE+02 O.OOOE+00 8.250E+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 4.480E+06

Rev.

00802 OFFSITE DOSE CALCULATION MANUAL Page 259 of318 2 Gaseous Effluent Pathway Dose Factors VEGETATION DOSE FACTORS CHILD (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract ZR 3.900E+06 8.580E+05 7.640E+05 0.OOOE-00 1.230E+06 0.OOOE+00 8.950E+08 ZR-97 5.640E+02 8.150E+01 4.81OE+01 0.OOOE+00 1.170E+02 0.OOOE+00 1.230E+07 NB-95 4.100E+05 1.590E+05 1.140E+05 0.OOOE+00 1.500E+05 0.OOOE+00 2.950E+08 NB-97 4.900E-06 8.850E-07 4.130E-07 0.OOOE+00 9.820E-07 0.OOOE+00 2.730E-01 MO-99 0.OOOE+00 7.830E+06 1.940E+06 0.OOOE+00 1.670E+07 0.OOOE+00 6.480E+06 TC-99M 4.650E+00' 9.120E+00 1.510E+02 0.OOOE+00 1.330E+02 4.630E+00 5.190E+03 TC-101 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RU-103 1.550E+07 0.OOOE+00 5.940E+06 0.OOOE+00 3.890E+07 0.OOOE+00 3.990E+08 RU-105 9.170E+01 0.OOOE+00 3.330E+01 0.OOOE+00 8.060E+02 0.OOOE+00 5.980E+04 RU-106 7.450E+08 0.OOOE+00 9.300E+07 0.OOOE+00 1.010E+09 0.OOOE+00 1.160E+10 RH-103M 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RH-106 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 AG-110M 3,220E+07 2.170E+07 1.740E+07 0.OOOE+00 4.050E+07 0.000E+00 2.580E+09 SB-122 3.050E+05 3.180E+05 3.850E+06 5.050E+04 1.500E+05 6.540E+04 3.790E+07 SB-124 3.520E+08 4.570E+06 1.230E+08 7.780E+05 0.OOOE+00 1.960E+08 2,200E+09 SB-125 4.990E+08 3.850E+06 1.050E+08 4.620E+05 0.000E+00 2.780E+08 1.190E+09 TE-125M 3.510E+08 9.500E+07 4.670E+07 9.840E+07 0.OOOE+00 0.OOOE+00 3.380E+08 TE-127M' 1.320E+09 3.560E+08 1.570E+08 3.160E+08 3.770E+09 0.OOOE+00

'1.070E+09 TE-127 1.OOOE+04 2.700E+03 2.150E+03 6.930E+03 2.850E+04 0.OOOE+00, 3.910E+05 TE-129M 8.540E+08 2.390E+08 1.330E+08 2.750E+08 2.510E+09 0.OOOE+00 1.040E+09 TE-129 1.150E-03 3.220E-04 2.740E-04 8.220E-04 3.370E-03 0.OOOE+00 7.170E-02 TE-131M 1.540E+06 5.330E+05 5.680E+05 1.100E+06 5.160E+06 0.OOOE+00 2.160E+07 TE-1 31 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 TE-132 6.980E+06 3.090E+06 3.730E+06 4.500E+06 2.870E+07 0.OOOE+00 3.11OE+07 1-130 6.210E+05 1.260E+06 6.470E+05 1.380E+08 1.880E+06 0.OOOE+00 5.870E+05 1-131 1.430E+08 1.440E+08 8.180E+07 4.760E+10 2.360E+08 0.OOOE+00 1.280E+07 1-132 9.200E+01 1.690E+02 7.770E+01 7.840E+03 2.590E+02 0.OOOE+00 1.990E+02 1-133 3.590E+06 4.440E+06 1.680E+06 8.250E+08 7.400E+06 0.OOOE+00 1.790E+06 1-134 1.700E-04 3.160E-04 11.460E-04 7.280E-03 4.840E-04 0.OOOE+00 2.100E-04 1-135 6.540E+04 1.180E+05 5.570E+04 1.040E+07 1.810E+05 0.OOOE+00 8.980E+04 CS-134 1.600E+10 2.630E+10 5.540E+09 0.OOOE+00 8.140E+09 2.920E+09 1.420E+08 CS-136 8.060E+07 2.220E+08 1.430E+08 0.OOOE+00 1.180E+08 1.760E+07 7.790E+06 CS-137 2.390E+10 2.290E+10 3.380E+09 O.OOOE+00 7.460E+09 2.680E+09 1.430E+08 CS-1 38 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00

OFFSlTE DOSE CALCULATION MANUAL Rev.

00802 Page 260 of 318 int Gaseous Effluent Pathway Dose Factors VEGETATION DOSE FACTORS CHILD (m2*mrem/yr per uCi/sec)

Thody Thyroid Nuclide Bone Liver Kidney Lung Gitract BA-139 BA-140 BA-141 BA-142 LA-140 LA-142 CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 EU-154 EU-1 55 W-187 NP-239 5.11 OE-02 2.770E+08 0.OOOE+00 0.OOOE+00 3.230E+03 2.320E-04 6.350E+05 1.730E+03 1.270E+08 1.480E+05 0.000E+00 7.160E+04 1.660E+08 3.440E+07 6.470E+04 2.550E+03 2.730E-05 1.480E-03 2.430E+05 1.620E+07 O.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 1.1 30E+03 3.810E+02 7.400E-05 2.320E-05 3.260E+05 4.840E+04 9.360E+05 1.360E+02 3.980E+07 6.780E+06 4.460E+04 7.370E+03 0.000E+00 0.OOOE+00 5.800E+04 4.490E+03 1.500E+07 1.370E+07 2.480E+06 1.940E+06 3.830E+04 1.720E+04 1.830E+02 1.290E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.000E+00 0.000E+00 0.000E+00 2.380E-05 1.61 OE-05 7.900E+04 1.450E+05 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 1.430E+05 0.000E+00 3.930E+02 0.000E+00 2.210E+07 0.000E+00 2.410E+04 0.000E+00 0.000E+00 0.OOOE+00 3.180E+04 0.000E+00 6.570E+07 0.000E+00 9.280E+06 0.000E+00 0.000E+00 0.000E+00 5.300E+02 0.000E+00 2.950E+00 1.400E+08 0.000E+00 0.000E+00 3.150E+07 1470E+01 4.070E+08 1.370E+07 1.040E+10 1.600E+08 0.000E+00 9.180E+07 3.480E+09 6.200E+09 5.380E+06 1.360E+07

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 261 Of 318 2 Gaseous Effluent Pathway Dose Factors VEGETATION DOSE FACTORS INFANT (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung GItract THIS PATHWAY IS NOT APPLICABLE TABLE INTENTIONALLY LEFT BLANK

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 262 of 318 Gaseous Effluent Pathway Dose Factors GROUND PLANE DOSE FACTORS ADULT (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver Thody Thyroid Kidney Lung Gitract THIS PATHWAY IS NOT APPLICABLE TABLE INTENTIONALLY LEFT BLANK

Rev.

00802 OFFSITE DOSE CALCULATION MANUAL Page 263 of 318 ient Gaseous Effluent Pathway Dose Factors GROUND PLANE DOSE FACTORS TEEN (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver

ýTbody Thyroid Kidney Lung Gitract H-3 0.000E006 O.000E.+60 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 C-14 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+0 0.OOOE+00 0.OOOE+00 0.OOOE+00 NA-24 1.210E+07 1.210E+07 1.210E+07 1.210E+07 1.210E+07 1.210E+07 1.210E+07 P-32 0.OOOE+/-00 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 CR-51 4.680E+06 4.680E+06 4.680E+06 4.680E+06 4.680E+06 4.680E+06 4.680E+06 MN-54 1.340E+09 1.340E+09 1.340E+09 1.340E+09 1.340E+09 1.340E+09 1.340E+09 MN-56 9.050E+05 9.050E+05 9.050E+05 9.050E+05 9.050E+05 9.050E+05 9.050E+05 FE-55 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 FE-59 2.750E+08 2.750E+08 2.750E+08 2.750E+08 2.750E+08 2.750E+08 2.750E+08 CO-58 3.820E+08 3.820E+08 3.820E+08 3.820E+08 3.820E+08 3.820E+08 3.820E+08 CO-60 2.160E+10 2.160E+10 2.160E+10 2.160E+10 2.160E+10 2.160E+10 2.160E+10 NI-63 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 NI-65 2.970E+05 2.970E+05 2.970E+05 2.970E+05 2.970E+05 2.970E+05 2.970E+05 CU-64 6.090E+05 6.090E+05 6.090E+05 6.090E+05 6.090E+05 6.090E+05 6.090E+05 ZN-65 7.450E+08 7.450E+08 7.450E+08 7.450E+08 7.450E+08 7.450E+08 7.450E+08 ZN-69 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-83 4.890E+03 4.890E+03 4.890E+03 4.890E+03 4.890E+03 4.890E+03 4.890E+03 BR-84 2.030E+05 2.030E+05 2.030E+05 2.030E+05 2.030E+05 2.030E+05 2.030E+05 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 RB-86 8.980E+06 8.980E+06 8.980E+06 8.980E+06 8.980E+06 8.980E+06 8.980E+06 RB-88 3.290E+04 3.290E+04 3.290E+04 3.290E+04 3.290E+04 3.290E+04 3.290E+04 RB-89 1.210E+05 1.210E+05 1.210E+05 1.210E+05 1.210E+05 1.210E+05 1.210E+05 SR-89 2.160E+04 2.160E+04 2.160E+04 2.160E+04 2.160E+04 2.160E+04 2.160E+04 SR-90 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+/-00 0.OOOE+00 0.000E+00 0.OOOE+00 SR-91 2.190E+06 2.190E+06 2.190E+06 2.190E+06 2.190E+06 2.190E+06 2.190E+06 SR-92 7.770E+05 7.770E+05 7.770E+05 7.770E+05 7.770E+05 7.770E+05 7.770E+05 Y-90 4.480E+03 4.480E+03 4.480E+03 4.480E+03 4.480E+03 4.480E+03 4.480E+03 Y-91M 1.010E+05 1.010E+05 1.010E+05 1.010E+05 1.010E+05 1.010E+05 1.010E+05 Y-91 1.080E+06 1.080E+06 1.080E+06 1.080E+06 1.080E+06 1.080E+06 1.080E+06 Y-92 1.800E+05 1.800E+05 1.800E+05 1.800E+05 1.800E+05 1.800E+05 1.800E+05 Y-93 1.850E+05 1.850E+05 1.850E+05 1.850E+05 1.850E+05 1.850E+05 1.850E+05 ZR-95 2.480E+08 2.480E+08 2.480E+08 2.480E+08 2.480E+08 2.480E+08 2.480E+08 ZR-97 2.940E+06 2.940E+06 2.940E+06 2.940E+06 2.940E+06 2.940E+06 2.940E+06 NB-95 1.360E+08 1.360E+08 1.360E+08 1.360E+08 1.360E+08 1.360E+08 1.360E+08

OFF~lE..

Rev.

00802 OFFSITE DOSE CALCULATION MANUAL Page 008 (A~~Page 264of 318-


....-----------...---...... 2 Gaseous Effluent Pathway Dose Factors GROUND PLANE DOSE FACTORS TEEN (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract MO-99 TC-99M TC-l101 RU-103 RU-105 RU-106 RH-103M RH-106 AG-110M SB-122 TE-125M TE-127M TE-127 TE-129M TE-129 TE-131M TE-131 TE-132 I-130 1-131 1-132 1-133 1-134 1-135 CS-134 CS-136 CS-137 CS-138 BA-139 BA-140 BA-141 BA-142 4.050E+06 1.830E+05 2.040E+04 1.090E+08 6.360E+05 4.21 OE+08 0.OOOE+00 0.OOOE+00 3.470E+09 1.070E+07 1.550E+06 9.170E+04 3.000E+03 2.OOOE+07 2.600E+04 8.030E+06 2.930E+04 4.220E+06 5.530E+06 1.720E+07 1.240E+06 2.470E+06 4.490E+05 2.560E+06 6.750E+09 1.490E+08 1.040E+10 3.590E+05 1.060E+05 2.050E+07 4.180E+04 4.490E+04 4.050E+06 1.830E+05 2.040E+04 1.090E+08 6.360E+05 4.21 OE+08 0.000E+00 0.OOOE+00 3.470E+09 1.070E+07 1.550E+06 9.170E+04 3.OOOE+03 2.000E+07 2.600E+04 8.030E+06 2.930E+04 4.220E+06 5.530E+06 1.720E+07 1.240E+06 2.470E+06 4.490E+05 2.560E+06 6.750E+09 1.490E+08 1.040E+10 3.590E+05.

1.060E+05 2.050E+07 4.180E+04 4.490E+04 4.050E+06 1.830E+05 2.040E+04 1.090E+08 6.360E+05 4.210E+08 0.0.OE+00 0.OOOE+00 3.470E+09 1.070E+07 1.550E+06 9.170E+04 3.000E+03 2.OOOE+07 2.600E+04 8.030E+06 2.930E+04 4.220E+06 5.530E+06 1.720E+07 1.240E+06 2.470E+06 4.490E+05 2.560E+06 6.750E+09 1.490E+08 1.040E+10 3.590E+05 1.060E+05 2.050E+07 4.180E+04 4.490E+04 4.050E+06 1.830E+05 2.040E+04 1.090E+08 6.360E+05 4.21 OE+08 0.OOOE+00 0.OOOE+00 3.470E+09 1.070E+07 1.550E+06 9.170E+04 3.OOOE+03 2.OOOE+07 2.600E+04 8.030E+06 2.930E+04 4.220E+06 5.530E+06 1.720E+07 1.240E+06 2.470E+06 4.490E+05 2.560E+06 6.750E+09 1.490E+08 1i040E+10 3.590E+05 1.060E+05 2.050E+07 4.180E+04 4.490E+04 4.050E+06 1.830E+05 2.040E+04 1.090E+08 6.360E+05 4.21 OE+08 0.OOOE+00 0.00mE+00 3.470E+09 1.070E+07 1.550E+06 9.170E+04 3.000E+03 2.OOOE+07 2.600E+04 8.030E+06 2.930E+04 4.220E+06 5.530E+06 1.720E+07 1.240E+06 2.470E+06 4.490E+05 2.560E+06 6.750E+09 1.490E+08 i.040E+ 10 3.590E+05 1.060E+05 2.050E+07 4.180E+04 4.490E+04 4.050E+06 1.830E+05 2.040E+04 1.090E+08 6.360E+05 4.21 OE+08 0.OOOE+00 0.OOOE+00 3.470E+09 1.070E+07 1.550E+06 9.170E+04 3.OOOE+03 2.OOOE+07 2.600E+04 8.030E+06 2.930E+04 4.220E+06 5.530E+06 1.720E+07 1.240E+06 2.470E+06 4.490E+05 2.560E+06 6.750E+09 1.490E+08 1.040E+10 3.590E+05 1.060E+05 2.050E+07 4.1 80E+04 4.490E+04 4.050E+06 1.830E+05 2.040E+04 1.090E+08 6.360E+05 4.2i10E+08 0.OOOE+00 0.OOOE+00 3.470E+09 1.070E+07 1.550E+06 9.1 70E+04 3.O00E+03 2.OOOE+07 2.600E+04 8.030E+06 2.930E+04 4.220E+06 5.530E+06 1.720E+07 1.240E+06 2.470E+06 4.490E+05 2.560E+66 6.750E+09 1.490E+08 1.040E+10 3.590E+05 1.060E+05 2.050E+07 4.180E+04 4.490E+04

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 265 of 318 2 Gaseous Effluent Pathway Dose Factors GROUND PLANE DOSE FACTORS TEEN (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract LA-140 LA-142 CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 EU-154 EU-1 55 W-187 NP-239 1.910E+07 7.360E+05 1.360E+07 2.320E+06 6.950E+07 0.OOOE+00 1.830E+03 8.400E+06 2.700E+10 9.570E+08 2.360E+06 1.710E+06

.1.910E+07 7.360E+05 1.360E+07 2.320E+06 6.950E+07 O.OOOE+00 1.830E+03 8.400E+06 2.700E+10 9.570E+08 2.360E+06 1.71 OE+06 1.910E+07 7.360E+05 1.360E+07 2.320E+06 6.950E+07 0.OOOE+00 1.830E+03 8.400E+06 2.700E+10 9.570E+08 2.360E+06 1.710E+06 1.910E+07 7.360E+05 1.360E+07 2.320E+06 6.950E+07 0.000E+00 1.830E+03 8.400E+06 2.700E+10 9.570E+08 2.360E+06 1.71 OE+06 1.91 OE+07 7.360E+05 1.360E+07 2.320E+06 6.950E+07 0.OOOE+00 1.830E+03 8.400E+06 2.700E+10 9.570E+08 2.360E+06 1.710E+06 1.910E+07 7.360E+05 1.360E+07 2.320E+06 6.950E+07 0.000E+00 1.830E+03 8.400E+06 2.700E+10 9.570E+08 2.360E+06 1.71 OE+06 1.91 0E+07 7.360E+05 1.360E+07 2.320E+06 6.950E+07 0.OOOE+00 1.830Et03 8.400E+06 2.700E+10 9.570E+08 2.360E+06 1.71oE+06

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 O

l O

C L

O NPage 266 of 318 2 Gaseous Effluent Pathway Dose Factors GROUND PLANE DOSE FACTORS CHILD (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver Thody Thyroid Kidney Lung Gitract H-3 C-14 NA-24 P-32 CR-51 MN-54 MN-56 FE-55 FE-59 CO-58 CO-60 NI-63 NI-65 CU-64 ZN-65 ZN-69 BR-83 BR-84 BR-85 RB-86 RB-88 RB-89 SR-89 SR-90 SR-91 SR-92 Y-90 Y-91 M Y-91 Y-92 Y-93 ZR-95 ZR-97 NB-95 0.OOOE+00 0.OOOE+00 1.210E+07 0.000E+00 4.680E+06 1.340E+09 9.050E+05 0.000E+00 2.750E+08 3.820E+08 2.160E+10 0.000E+00 2.970E+05 6.090E+05 7.450E+08 0.000E+00 4.890E+03 2.030E+05 0.000E+00 8.980E+06 3.290E+04 1.210E+05 2.160E+04 0.000E+00 2.190E+06 7.770E+05 4.480E+03 1.010E+05 1.080E+06 1.800E+05 1.850E+05 2.480E+08 2.940E+06 1.360E+08 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 1.210E+07 1.210E+07 0.OOOE+00 0.000E+00 4.680E+06 4.680E+06 1.340E+09 1.340E+09 9.050E+05 9.050E+05 0.OOOE+00 0.000E+00 2.750E+08 2.750E+08 3.820E+08 3.820E+08 2.160E+10 2.160E+10 0.000E+00 0.000E+00 2.970E+05 2.970E+05 6.090E+05 6.090E+05 7.450E+08 7.450E+08 0.OOOE+00 0.000E+00 4.890E+03 4.890E+03 2.030E+05 2.030E+05 0.OOOE+00 0.OOOE+00 8.980E+06 8.980E+06 3.290E+04 3.290E+04 1.210E+05 1.210E+05 2.160E+04 2160E+04 0.000E+00 0.OOOE+00 2.190E+06 2.190E+06 7.770E+05 7.770E+05 4.480E+03 4.480E+03 1.010E+05 1.010E+05 1.080E+06 1.080E+06 1.800E+05 1.800E+05 1.850E+05 1.850E+05 2.480E+08 2.480E+08 2.940E+06 2.940E+06 1.360E+08 1.360E+08 O.O00E+00 O.000E+00 1.210E+07 O.O00E+00 4.680E+06 1.340E+09 9.050E+05 O.O00E+00 2.750E+08 3.820E+08 2.160E+10 O.O00E+00 2.970E+05 6.090E+05 7.450E+08 O.O00E+00 4.890E+03 2.030E+05 O.O00E+00 8.980E+06 3.290E+04 1.210E+05 2.160E+04 O.O00E+00 2.190E+06 7.770E+05 4.480E+03 1.010E+05 1.080E+06 1.800E+05 1.850E+05 2.480E+08 2.940E+06 1.360E+08 0.000E+00 0.000E+00 0.000E+00 0.000E+00 1.210E+07 1.210E+07 0.000E+00 0.000E+00 4.680E+06 4.680E+06 1.340E+09 1.340E+09 9.050E+05 9.050E+05 O.O00E+00 OO.00E+00 2.750E+08 2.750E+08 3.820E+08 3.820E+08 2.160E+10 2.160E+10 O.O00E+00 O.O00E+00 2.970E+05 2.970E+05 6.090E+05 6.090E+05 7.450E+08 7.450E+08 O.O00E+00 O.O00E+00 4.890E+03 4.890E+03 2.030E+05 2.030E+05 O.O00E+00 0.0002+00 8.980E+06 8.980E+06 3.290E+04 3.290E+04 1.210E+05 1.210E+05 2.160E+04 2.160E+04 0.000E+00 0.000E+00 2.190E+06 2.190E+06 7.770E+05 7.770E+05 4.480E+03 4.480E+03 1.010E+05 1.010E+05 1.080E+06 1.080E+06 1.800E+05 1.800E+05 1.850E+05 1.850E+05 2.480E+08 2.480E+08 2.940E+06 2.940E+06 1.360E+08 1.360E+08 O.002E+00 O.002E+00 1.210E+07 O.000E+00 4.680E+06 1.340E+09 9.050E+05 O.000E+00 2.750E+08 3.820E+08 2.160E+10 OO.00E+00 2.970E+05 6.090E+05 7.450E+08 O.000E+00 4.890E+03 2.030E+05 0.000E+00 8.980E+06 3.290E+04 1.210E+05 2.160E+04 0.000E+00 2.190E+06 7.770E+05 4.480E+03 1.010E+05 1.080E+06 1.800E+05 1.850E+05 2.480E+08 2.940E+06 1.360E+08

OFFSITE DOSE CALCULATION MANUAL Pagev 267of 318 2 Gaseous Effluent Pathway Dose Factors GROUND PLANEDOSE FACTORS CHILD (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract MO-99 4.050E+06 4.050E+06 4.050E+06 4:050E+06 4.050E+06 4.050E+06 4.050E+06 TC-99M 1.I 830E+05 1.830E+05 1.830E+05 1.830E+05 1.830E+05 1.830E+05 1.830E+05 TC-101 2.040E+04 2.040Et04 2.040E+04 2.040E+04 2.040E+04 2.040E+04 2.040E+04 RU-103 1.090E+08 1.090E+08 1.090E+08 1.090E+08 1.090E+08 1.090E+08 1.090E+08 RU-105 6.360E+05 6.360E+05 6.360E+05 6.360E+05 6.360E+05 6.360E+05 6.360E+05 RU-106 4.210E+08 4.210E+08 4.210E+08 4.210E+08 4.210E+08 4.21OE+08 4.210E+08 RH-103M 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RH-106 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 AG-110M 3.470E+09 3.470E+09 3.470E+09 3.470E+09 3.470E+09 3.470E+09 3.470E+09 SB-122 1.070E+07 1.070E+07 1.070E+07 1.070E+07 1.070E+07 1.070E+07 1.070E+07 TE-125M 1.550E+06 1.550E+06 1.550E+06 1.550E+06 1.550E+06 1.550E+06 1.550E+06 TE-127M 9170E+04 9.170E+04 9.170E+04 9.170E+04 9.170E+04 9.170E+04 9.170E+04 TE-127 3.OOOE+03 3.OOOE+03 3.OOOE+03 3.OOOE+03 3.OOOE+03 3.OOOE+03 3.000E+03 TE-129M 2.OOOE+07 2.00OE+07 2.OOOE+07 2.OOOE+07 2.000E+07 2.OOOE+07 2.OOOE+07 TE-129 2.600E+04 2.600E+04 2.600E+04 2.600E+04 2.600E+04 2.600E+04 2.600E+04 TE-131M 8.030E+06 8.030E+06 8.030E+06 8.030E+06 8.030E+06 8.030E+06 8.030E+06 TE-131 2.930E+04 2.930E+04 2.930E+04 2.930t+04 2.930E+04 2.930E+04 2.930E+04 TE-132 4.220E+06 4.220E+06 4.220E+06 4.220E+06 4.220E+06 4.220E+06 4.220E+06 1-130 5.530E+06, 5.530E+06 5.530E+06 5.530E+06 5.530E+06 5.530E+06 5.530E+06 1-131 1.720E+07 1.720E+07 1.720E+07 1.720E+07 1.720E+07 1.720E+07 1.720E+07 1-132 1.240E+06 1.240E+06 1.240E+06 1.240E+06 1.240E+06 1.240E+06 1.240E+06 1-133 2.470E+06 2.470E+06 2.470E+06 2.470E+06 2.470E+06 2.470E+06 2.470E+06 1-134 4.490E+05 4.490E+05 4.490E+05 4.490E+05 4.490E+05 4.490E+05 4.490E+05 1-135 2.560E+06 2.560E+06 2.560E+06 2.560E+06 2.560E+06 2.560E+06 2.560E+06 CS-134 6.750E+09 6.750E+09 6.750E+09 6.750E+09 6.750E+09 6.750E+09 6.750E+09 CS-1 36 1.490E+08 1.490E+08 1.490E+08 1.490E+08 1.490E+08 1.490E+08 1.490E+08 CS-137 1.040E+10 1.040E+10 1.040E+10 1.040E+10 1.040E+10 1.040E+10 1.040E+10 CS-1 38 3.590E+05 3.590E+05 3.590E+05 3.590E+05 3.590E+05 3.590E+05 3.590E+05 BA-139 1.060E+05 1.060E+05 1.060E+05 1.060E+05 1.060E+05 1.060E+05 1.060E+05 BA-140 2.050E+07 2.050E+07 2.050E+07 2.050E+07 2.050E+07 2.050E+07 2.050E+07 BA-141 4.180E+04 4.180E+04 4.180E+04 4.180E+04 4.180E+04 4.180E+04 4.180E+04 BA-142 4.490E+04 4.490E+04 4.490E+04 4.490E+04 4.490E+04 4.490E+04 4.490E+04 LA-140 1.910E+07 1.910E+07 1.91OE+07 1.910E+07 1.910E+07 1.910E+07 1.910E+07 LA-142 7.360E+05 7.360E+05 7.360E+05 7.360E+05 7.360E+05 7.360E+05 7.360E+05

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 268 of 318 2 Gaseous Effluent Pathway Dose Factors GROUND PLANE DOSE FACTORS CHILD (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver

Tbody, Thyroid Kidney Lung Gitract CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 EU-154 EU-155 W-187 NP-239 1.360E+07 2.320E+06 6.950E+07 O.OOOE+00 1.830E+03 8.400E+06 2.700E+10 9.570E+08 2.360E+06 1.71 OE+06 1.360E+07 1.360E+07 1.360E+07 1.360E+07 2.320E+06 2.320E+06 2.320E+06 2.320E+06 6.950E+07 6.950E+07 6.950E+07 6.950E+07 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 1.830E+03 1.830E+03 1.830E+03 1.830E+03 8.400E+06 8.400E+06 8.400E+06 8.400E+06 2.700E+10 2.700E+10 2.700E+10 2.700E+10 9.570E+08 9.570E+08 9.570E+08 9.570E+08 2.360E+06 2.360E+06 2.360E+06 2.360E+06 1.710E+06 1.710E+06 1.710E+06 1.710E+06 1.360E+07 1.360E+07 2.320E+06 2.320E+06 6.950E+07 6.950E+07 0.OOOE+00 0.OOOE+00 1.830E+03 1.830E+03 8.400E+06 8.400E+06 2.700E+10 2.700E+10 9.570E+08 9.570E+08 2.360E+06 2.360E+06 1.710E+06 1.710E+06

.Rev.

00802 OFFSITE DOSE CALCULATION MANUAL RPage 269of318 2, Gaseous Effluent Pathway Dose: Factors GROUND PLANE DOSE FACTORS INFANT (rm2*mrem/yr peruCi/sec),

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract H-3 C-14 NA-24 P-32 CR-51 MN-54 MN-56 FE-55 FE-59 CO-58

.CO-60 NI-63 NI-65 CU-64 ZN-65 ZN-69 BR-83 BR-84 BR-85 RB-86 RB-88 RB-89 SR-89 SR-90 SR-91 SR-92 Y-90 Y-91M Y-91 Y-92 Y-93 ZR-95 0.OOOE+00.

0.OOOE+00 0.OOOE+00 0.0 OOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OO!Em+oo 1.210E+07 1.210E+07 1.21 OE+07 O.OOOE+00 0.0OOE+60 0.OOOE+00 4.680E+06 4.680E+06 4.680E+06 1.340E+09' 1.340E+09 1.340E+09 9.050E+05 9.050E+05

.9.050E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.750E+08 2.750E+08 2.750E+08 3.820E+08 3.820E+08 3.820E+08r 2.160E+10 2.160E+10 2.160E+10 0.OOOE+00 0.OOOE+00-0.OOOE+00 2.970E+05 2.970E+05 2.970E+05 6.090E+05 6.090E+05 6.090E+05 7.450E+08 7.450E+08 7.450E+08 0.OOOE+00' 0.OOOE+00 0.OOOE+O0 4.890E+03 4.890E+03 4.890E+03 2.030E+05 2.030E+05 2.030E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 8.986E+06 8.980E+06 8.980E+06 3.290E+04 3.290E+04 3.290E+04 1.210E+05 1.21 OE+05 1.21 OE+05 2.160E+04 2.160E+04 2.160E+04 0.OOOE+010 0.OOOE+00 0.OOOE+00 2.190E+06 2.190E+06 2.190E+06 7.770E+05 7.770E+-05 7.770E+ý05 4.480E+03 4.480E+/-03 4.480E+03 1.0IOE+05 1.010E+05 1.010E+/-05 1.080E+06 1.080E+06 1.080E+06 1.800E+05' 1.800E+05 1.800E+06 1.'850E+05 1.850E+05 1.850E-'05 2.480E+08 2.460E+08 2.480E+08 1.210E+07 0.OOOE+00, 4.680E+06 1.340E+Q09 9.050E+05 0.OOOE+0.0 2.750E+08 3.820E+08 2.160E+10 0.OOOE+00 2.970E+05 6.090E+05*

7.450E+08 0O.OOOE+00 4.890E+03 2.030E+05 0.OOOE+00 8.980E+06 3.290E+04 1.210E+05 2.1 60E+04 0.OOOE+00 2.19 90E+06.

7.770E+065 4.480E+03 1.010OE+05 1.080E+06 1.800E+05 1.850E+05 2.480E+08 0.OOOE+00 0.OOOE+00 1.210OE+07, 0.OOOE+00 4.680E+06 1.340E+09 9.050E+05 0.OOOE+00 3.820E+08 2.160E+10 0.OOOE+00 2.970E+05 6.090E+05 7.450E+08 b.OOOE+00 4.890E+03 2.030E+05, 0.OOOE+00 8.980E+06 3.290E+04 1.210OE+05 2.1 60E+04 0.OOOE+00 2.1 90E+06 7.770E+05 4.480E+03 1.010E+05 1.080E+06 1.800E+05 1.850E+05 2.480E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.210E+07 1.210E+07 0.000E+00 0.OOOE+00*

4.680E+06 4.680E+06 1.340E+09 1.340E+09 9.050E+05 9.050E+05 U0.

E+00 0.000E+00 2.750E+08 2.750E+08 3.820E+08 3.820E+08 2.160E+10 2.160E+10 0.OOOE+00 0.000E+00 2.970E+05 2.970E+05 6.090E+05 6.090E+05 7.450E+08 7.450E+08 0.OOOE+00 0.OOOE+00 4.890E+03 4.890E+03 2.030E+05 2.030E+05 0.OOOE+00 0.OOOE+QO 8.980E+06, 8.980E+06 3.290E+04

3. 290E+04 1.210E+05 1.210E+05 2.160E+04 2.160E+04 0.OOOE+00 0.OOOE+00 2.190E+06 2.190E+06 7.770E+05 7.770E+05 4.480E+03 4.480E+03 1.010E+/-05 1.010E+05 1.080E+06 1.080E+06 1.800E+05 1.800E+05 1.850E+05 1.850E+05 2.480E+08 2.480E+08 ZR-97 2.940E+06 2.940E+06 2.940E+06 294E0 290+0 294E6 294+6 2.940E+06 2.940E+06 2.940E+06 2.940E+06

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 270 of 318 2 Gaseous Effluent Pathway Dose Factors GROUND PLANE DOSE FACTORS INFANT (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract NB-95 MO-99 TC-99M TC-101 RU-103 RU-105 RU-106 RH-103M RH-1 06 AG-110M SB-122 TE-125M TE-127M TE-127 TE-129M TE-129 TE-131M TE-131 TE-132 I-130 1-131 1-132 I-133 1-134 1-135 CS-1 34 CS-136 CS-137 CS-138 BA-139 BA-140 BA-141 BA-1 42 1.360E+08 4.050E+06 i1.830E+05 2.040E+04 i1.090E+08 6.360E+05 4.21iOE+08 0.OOOE+00 0.OOOE+00 3.470E+09 1.070E+07 i1.550E+06 9.170E+04 3.OOOE+03 2.OOOE+07 2.600E+04 8.030E+06 2.930E+04 4.220E+06 5.530E+06 1.720E+07 1.240E+06 2.470E+06 4.490E+05 2.560E+06 6.750E+09 1.490E+08 1.040E+10 3.590E+05 I1.060E+05 2.050E+07

4. 180E+04 4.490E+04 1.360E4-08 4.050E+06 i1.830E+05 2.040E+04 1.090E+08 6.360E+05 4.21 OE+08 0.OOOE+00 0.OOOE+00 3.470E+09 1.070E+07 i1.550E+06 9.170E+04 3.OOOE+03 2.OOOE+07 2.600E+04 8.030E+06 2.930E+04 4.220E+06 5.530E+06 1.720E+07 1.240E+06 2.470E+06 4.490E+05 2.560E+06 6.750E+09 1.490E+08 1.040E+10 3.590E+05 1.060E+05 2.050E+07 4.180E+04 4.490E+04 1.360E+08 4.050E+06 1.830E+05 2.040E+04 1.090E+08 6.360E+05 4.21 OE+08 0.OOOE+00 0.OOOE+00 3.470E+09 1.070E+07 1.550E+06 9.170E+04 3.OOOE+03 2.OOOE+07 2.600E+04 8.030E+06 2.930E+04 4.220E+06 5.530E+06 1.720E+07 1.240E+06 2.470E+06 4.490E+05 2.560E+I06 6.750E+09 1.490E+08 1.040E+10 3.590E+05 1.060E+05 2.050E+07 4.180E+04 4.490E+04 1.360E+08 1.360E+08 4.050E+06 4.050E+06 1.830E+05 1.830E+05 2.040E+04 2.040E+04 1.090E+08 1.090E+08 6.360E+05 6.360E+05 4.21OE+08 4.21OE+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.470E+09 3.470E+09 1.070E+07 1.070E+07 1.550E+06 1.550E+06 9.170E+04 9.170E+04 3.OOOE+03 3.OOOE+03 2.OOOE+07 2.OOOE+07 2.600E+04 2.600E+04 8.030E+06 8.030E+06 2.930E+04 2.930E+04 4.220E+06 4.220E+06 5.530E+06 5.530E+06 1.720E+07 1.720E+07 1.240E+06 1.240E+06 2.470E+06 2.470E+06 4.490E+05 4.490E+05 2.560E+06 2.560E+06 6.750E+09 6.750E+09 1.490E+08 1.490E+08 1.040E+10 1.040E+10 3.590E+05 3.590E+05 1.060E+05 1.060E+05 2.050E+07 2.050E+07 4.180E+04 4.180E+04 4.490E+04 4.490E+04 1.360E+08 1.360E+08 4.050E+06 4.050E+06 1.830E+05 1.830E+05 2.040E+04 2.040E+04 1.090E+08 1.090E+08 6.360E+05 6.360E+05 4.210E+08 4.210E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.470E+09 3.470E+09 1.070E+07 1.070E+07 1.550E+06 1.550E+06 9.170E+04 9.170E+04 3.OOOE+03 3.OOOE+03 2.OOOE+07 2.OOOE+07 2.600E+04 2.600E+04 8.030E+06 8.030E+06 2.930E+04 2.930E+04 4.220E+06 4.220E+06 5.530E+06 5.530E+06 1.720E+07 1.720E+07 1.240E+06 1.240E+06 2.470E+06 2.470E+06 4.490E+05 4.490E+05 2.560E+06 2.560E+06 6.750E+09 6.750E+09 1.490E+08 1.490E+08 1.040E+10 1.040E+10 3.590E+05 3.590E+05 1.060E+05 1.060E+05 2.050E+07 2.050E+07 4.180E+04 4.180E+04 4.490E+04 4.490E+04 I

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 271 of 318 2 Gaseous Effluent Pathway Dose Factors GROUND PLANE DOSE FACTORS INFANT (m2*mrem/yr per uCi/sec)

Nuclide Bone Liver Thody Thyroid Kidney Lung Gitract LA-140 LA-142 CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 EU-1 54 EU-155 W-187 NP-239 1.910E+07 7.360E+05 1.360E+07 2.320E+06 6.950E+07 O.OOOE+00 1.830E+03 8.400E+06 2.700E+10 9.570E+08 2.360E+06 1.710E+06 1.910E+07 7.360E+05 1.360E+07 2.320E+06 6.950E+07 0.OOOE+00 1.830E+03 8.400E+06 2.700E+10 9.570E+08 2.360E+06 1.710E+06 1.910E+07 7.360E+05 1.360E+07 2.320E+06 6.950E+07 0.OOOE+00 1.830E+03 8.400E+06 2.700E+10 9.570E+08 2.360E+06 1.710E+06 1.910E+07 7.360E+05 1.360E+07 2.320E+06 6.950E+07 0.OOOE+00 1.830E+03 8.400E+06 2.700E+10 9.570E+08 2.360E+06 1.710E+06 1.910E+07 7.360E+05 1.360E+07 2.320E+06 6.950E+07 0.OOOE+00 1.830E+03 8.400E+06 2.700E+10 9.570E+08 2.360E+06 1.710E+06 1.910E+07 7.360E+05 1.360E+07 2.320E+06 6.950E+07 0.OOOE+00 1,830E+03 8.400E+06 2.700E+10 9.570E+08 2.360E+06 1.710E+06 1.910E+07 7.360E+05 1.360E+07 2.320E+06 6.950E+07 0.000E+00 1.830E+03 8.400E+06 2.700E+10 9.570E+08 2.360E+06 1.71 0E+06

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 272 of 318 2 Gaseous Effluent Pathway Dose Factors INHALATION DOSE FACTORS ADULT (mrem/yr per uCi/m 3)

Nuclide Bone Liver Thody Thyroid Kidney Lung Gitract H-3 0.OOOE+00 1.260E+03 1.260E+03 1.260E+03 1.260E+03 1.260E+03 1.260E+03 C-14 1.820E+04 3.410E+03 3.410E+03 3.410E+03 3.410E+03 3.410E+03 3.410E+03 NA-24 1.020E+04 1.020E+04 1.020E+04 1.020E+04 1.020E+04 1.020E+04 1.020E+04 P-32 1.320E+06 7.710E+04 5.010E+04 O.OOOE+00 O.OOOE+00 0.OOOE+00 8.640E+04 CR-51 0.OOOE+00 O.OOOE+00 1.OOOE+02 5.950E+01 2.280E+01 1.440E+04 3.320E+03 MN-54 0.OOOE+00 3.960E+04 6.300E+03 0.OOOE+00 9.840E+03 1.400E+06 7.740E+04 MN-56 0.OOOE+00 1.240E+00 1.830E-01 O.OOOE+00 1.300E+00 9.440E+03 2.020E+04 FE-55 2.460E+04 1.700E+04 3.940E+03 0.OOOE+00 0.OOOE+00 7.210E+04 6.030E+03 FE-59 1.180E+04 2.780E+04 1.060E+04 0.OOOE+00 0.OOOE+00 1.020E+06 1.880E+05 CO-57 0.OOOE+00 6.920E+02 6.71 OE+02 O.OOOE+00 0.OOOE+00 3.700E+05 3.140E+04 CO-58 0.OOOE+00 1.580E+03 2.070E+03 0.OOOE+00 0.OOOE+00 9.280E+05 1.060E+05 CO-60 0.OOOE+00 1.150E+04 1.480E+04 0.OOOE+00 0.OOOE+00 5.970E+06 2.850E+05 NI-63 4.320E+05 3.140E+04 1.450E+04 0.000E+00 0.000E+00 1.780E+05 1.340E+04 NI-65 1.540E+00 2.100E-01 9.120E-02 0.OOOE+00 0.OOOE+00 5.600E+03 1.230E+04 CU-64 0.OOOE+00 1.460E+00 6.150E-01 0.OOOE+00 4.620E+00 6.780E+03 4.900E+04 ZN-65 3.240E+04 1.030E+05 4.660E+04 0.OOOE+00 6.900E+04 8.640E+05 5.340E+04 ZN-69 3.380E-02 6.51 OE-02 4.520E-03 0.OOOE+00 4.220E-02 9.200E+02 1.630E+01 BR-82 0.OOOE+00 0.OOOE+00 1,350E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.040E+04 BR-83 0.OOOE+00 0.OOOE+00 2.41 OE+02 0.000E+00 0.OOOE+00 0.OOOE+00 2.320E+02 BR-84 0.OOOE+00 0.OOOE+00 3.130E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.640E-03 BR-85 0.000E+00 0.OOOE+00 1.280E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-86 0.OOOE+00 1.350E+05 5.900E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.660E+04 RB-88 0.000E+00 3.870E+02 1.930E+02 0.OOOE+00 0.OOOE+00 0.000E+00 3.340E-09 RB-89 0.000E+00 2.560E+02 1.700E+02 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 SR-89 3.040E+05 0.OOOE+00 8.720E+03 0.OOOE+00 0.OOOE+00 1.400E+06 3.500E+05 SR-90 9.920E+07 0.OOOE+00 6.100E+06 0.OOOE+00 0.OOOE+00 9.600E+06 7.220E+05 SR-91 6.190E+01 0.000E+00 2.500E+00 0.OOOE+00 0.OOOE+00 3.650E+04 1.910E+05 SR-92 6.740E+00 0.OOOE+00 2.910E-01 0.OOOE+00 0.000E+00 1.650E+04 4.300E+04 Y-90 2.090E+03 0.OOOE+00 5.610E+01 0.OOOE+00 0.000E+00 1.700E+05 5.060E+05 Y-91M 2.610E-01 0.OOOE+00 1.020E-02 0.OOOE+00 0.000E+00 1.920E+03 1.330E+00 Y-91 4.620E+05 0.OOOE+00 1.240E+04 0.OOOE+00 0.OOOE+00 1.700E+06 3.850E+05 Y-92 1.030E+01 0.000E+00 3.020E-01 0.OOOE+00 0.OOOE+00 1.570E+04 7.350E+04 Y-93 9.440E+01 0.OOOE+00 2.610E+00 0.OOOE+00 0.OOOE+00 4.850E+04 4.220E+05

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 273 of 318 2 Gaseous Effluent Pathway Dose Factors INHALATION DOSE FACTORS ADULT (mrem/yr per uCi/m 3 )

Nuclide Bone Liver Thody Thyroid Kidney Lung Gitract ZR-95 1.070E+05 3.440E+04 2.330E+04 0.OOOE+00 5.420E+04 1.770E+06 1.500E+05 ZR-97 9.680E+01 1.960E+01 9.040E+00 0.OOOE+00 2.970E+01 7.870E+04 5.230E+05 NB-95 1.410E+04 7.820E+03 4.210E+03 0.OOOE+00 7.740E+03 5.050E+05 1.040E+05 NB-97 2.220E-01 5.620E-02 2.050E-02 0.OOOE+00 6.540E-02 2.400E+03 2.420E+02 MO-99 0.OOOE+00 1.210E+02 2.300E+01 0.OOOE+00 2.910E+02 9.120E+04 2.480E+05 TC-99M 1.030E-03 2.91 OE-03 3.700E-02 0.OOOE+00 4.420E-02 7.640E+02 4.160E+03 TC-101 4.180E-05 6.020E-05 5.900E-04 0.OOOE+00 1.080E-03 3.990E+02 0.OOOE+00 RU-103 1.530E+03 O.OOOE+00 6.580E+02 0.OOOE+00 5.830E+03 5.050E+05 1.100E+05 RU-105 7.900E-01 0.OOOE+00 3.11OE-01 0.OOOE+00 1.020E+00 1.1OOE+04 4.820E+04 RU-106 6.910E+04 0.OOOE+00 8.720E+03 0.OOOE+O0 1.340E+05 9.360E+06 9.120E+05 RH-103M 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RH-106 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 AG-110M 1.080E+04 1.OOOE+04 5.940E+03 O.OOOE+00 1.970E+04 4.630E+06 3.020E+05 SB-122 3.1OOE+03 4.110E+03 4.11OE+04 1.070E+03 1.550E+03 1.670E+05 2.020E+05 SB-124 3.120E+04 5.890E+02 1.240E+04 7.550E+01 O.OOOE+00 2.480E+06 4.060E+05 SB-125 5.340E+04 5.950E+02 1.260E+04 5.400E+01 O.OOOE+00 1.740E+06 1.010E+05 TE-125M 3.420E+03 1.580E+03 4.670E+02 1.050E+03 1.240E+04 3.140E+05 7.060E+04 TE-127M 1.260E+04 5.770E+03 1.570E+03 3.290E+03 4.580E+04 9.600E+05 1.500E+05 TE-127 1.400E+00 6.420E-01 3.100E-01 1.060E+00 5.100E+00 6.510E+03 5.740E+04 TE-129M 9.760E+03 4.670E+03 1.580E+03 3.440E+03 3.660E+04 1.160E+06 3.830E+05 TE-129 4.980E-02 2.390E-02 1.240E-02 3.900E-02 1.870E-01 1.940E+03 1.570E+02 TE-131M 6.990E+01 4.360E+01 2.900E+01 5.500E+01 3.090E+02 1.460E+05 5.560E+05 TE-131 1.11OE-02 5.950E-03 3.590E-03 9.360E-03 4.370E-02 1.390E+03 1.840E+01 TE-132 2.600E+02 2.150E+02 1.620E+02 1.900E+02 1.460E+03 2.880E+05 5.100E+05 1-130 4.580E+03 1.340E+04 5.280E+03 1.140E+06 2.090E+04 7.690E+03 O.OOOE+00 1-131 2.520E+04 3.580E+04 2.050E+04 1.190E+07 6.130E+04 O.OOOE+00 6.280E+03 1-132 1.160E+03 3.260E+03 1.160E+03 1.140E+05 5.180E+03 O.OOOE+00 4.060E+02 1-133 8.640E+03 1.480E+04 4.520E+03 2.150E+06 2.580E+04 O.OOOE+00 8.880E+03 1-134 6.440E+02 1.730E+03 6.150E+02 2.980E+04 2.750E+03 O.OOOE+00 1.010E+00 1-135 2.680E+03 6.980E+03 2.570E+03 4.480E+05 1 11 OE+04 O.OOOE+00 5.250E+03 CS-1 34 3.730E+05 8.480E+05 7.280E+05 O.OOOE+00 2.870E+05 9.760E+04 1.040E+04 CS-1 36 3.900E+04 1.460E+05 1.100E+05 O.OOOE+00 8.560E+04 1.200E+04 1.170E+04 CS-137 4.780E+05 6.210E+05 4.280E+05 O.OOOE+00 2.220E+05 7.520E+04 8.400E+03 CS-138 3.310E+02 6.210E+02 3.240E+02 O.OOOE+00 4.800E+02 4.860E+01 1.860E-03

Rev.

00802 OFFSITE DOSE CALCULATION MANUAL Page 274 of 318 Gaseous Effluent Pathway Dose Factors INHALATION DOSE FACTORS ADULT (mrem/yr per uCi/m3)

Nuclide Bone Liver Thody Thyroid Kidney Lung Gitract BA-139 9.360E-01 6.660E-04 2.740E-02 O.OOOE+00 6.220E-04 3.760E+03 8.960E+02 BA-140 3.900E+04 4.900E+01 2.570E+03 0.000E+00 1.670E+01 1.270E+06 2.180E+05 BA-141 1.OOOE-01 7.530E-05 3.360E-03 O.OOOE+00 7.OOOE-05 1.940E+03 1.160E-07 BA-142 2.630E-02 2.700E-05 1.660E-03 O.OOOE+00 2.290E-05 1.190E+03 O.OOOE+00 LA-140 3.440E+02 1.740E+02 4.580E+01 O.OOOE+00 O.OOOE+00 1.360E+05 4.580E+05 LA-142 6.830E-01 3.100E-01 7.720E-02 O.OOOE+00 O.OOOE+00 6.330E+03 2.11OE+03 CE-141 1.990E+04 1.350E+04 1.530E+03 O.OOOE+00 6.260E+03 3.620E+05 1.200E+05 CE-143 1.860E+02 1.380E+02 1.530E+01 O.OOOE+00 6.080E+01 7.980E+04 2.260E+05 CE-144 3.430E+06 1.430E+06 1.840E+05 O.OOOE+00 8.480E+05 7.780E+06 8.160E+05 PR-143 9.360E+03 3.750E+03 4.640E+02 O.OOOE+00 2.160E+03 2.810E+05 2.OOOE+05 PR-144 3.010E-02 1.250E-02 1.530E-03 O.OOOE+00 7.050E-03 1.020E+03 2.150E-08 ND-147 5.270E+03 6.100E+03 3.650E+02 O.OOOE+00 3.560E+03 2.210E+05 1.730E+05 EU-154 5.920E+06 7.280E+05 5.180E+05 O.OOOE+00 3.490E+06 4.670E+06 2.720E+05 EU-155 8.080E+05 1.140E+05 7.370E+04 O.OOOE+00 5.270E+05 7.570E+05 4.760E+04 W-187 8.480E+00 7.080E+00 2.480E+00 O.OOOE+00 O.OOOE+00 2.900E+04 1.550E+05 NP-239 2.300E+02 2.260E+01 1.240E+01 O.OOOE+00 7.OOOE+01 3.760E+04

1. 190E+05

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 275 of 318 Gaseous Effluent Pathway Dose Factors INHALATION DOSE FACTORS TEEN (mrem/yr,per uCi/m 3)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract H-3 0.OOOE+00 1.270E+03 1.270E+03 1.270E+03 1.270E+03 1.270E+03-1.270E+03 C-14 2.600E+04 4.870E+03 4.870E+03 4.870E+03 4.870E+03 4.870E+03 4.870E+03 NA-24 1.380E+04 1.380E+04 1.380E+04 1.380E+04 1.380E+04 1.380E+04 1.380E+04 P-32 1.890E+06 1.100E+05.

7.160E+04 O.OOOE+00 0.OOOE+00 0.OOOE+00 9.280E+04 CR-51 0.OOOE+00 0.OOOE+00 1,350E+02 7.500E+01 3.070E+01 2.100E+04 3.OOOE+03 MN,54 0.OOOE+00 5.110E+04 8.400E+03 0.OOOE+00 1.270E+04 1.980E+06 6.680E+04 MN-56 O.OOOE+00 1.700E+00 2.520E-01 0.OOOE+00 1.790E+00 1.520E+04 5.740E+04 FE-55 3.340E+04 2.380E+04 5.540E+03 0.OOOE+00 0.OOOE+00 1.240E+05 6.390E+03 FE-59 1.590E+04 3.700E+04 1.430E+04 0.OOOE+00 0.000E+00 1.530E+06 1.780E+05 CO-57 0.OOOE+00 6.920E+02 9.200E+02 0.OOOE+00 0.OOOE+00 5.860E+05 3.140E+04 CO-58 0.OOOE+00 2.070E+03 2.780E+03 0.OOOE+00 0.OOOE+00 1.340E+06 9.520E+04 0O-60 0.OOOE+00 1.510E+04 1.980E+04 0.OOOE+00 0.OOOE+00 8.720E+06 2.590E+05 NI-63 5.800E+05 4.340E+04 1.980E+04 0.OOOE+00 O.OOOE+00 3.070E+05 1.420E+04 NI-65 2.180E+00 2.930E-01 1.270E-01 0.OOOE+00 0.OOOE+00 9.360E+03 3.670E+04 CU-64 0.OOOE+00 2.030E+00 8.480E-01 0.OOOE+00 6.410E+00 1.110E+04 6.140E+04 ZN-65 3.860E+04 1.340E+05 6.240E+04 0.OOOE+00 8,640E+04 1.240E+06 4.660E+04 ZN-69 4.830E-02.

9.200E-02 6.460E-03 0.00OE+00 6.020E-02 1.580E+03 2.850E+02 BR-82 0.OOOE+00 0.OOOE+00 1.820E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-83 0.OOOE+00 0.OOOE+00 3.440E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-84 0.OOOE+00 0.OOOE+00 4.330E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-85 0.OOOE+00 0.OOOE+00 1.830E+01 0.OOOE+00 0,OOOE+00 0.OOOE+00, O.OOOE+00 RB-86 0.OOOE+00 1.900E+05 8.400E+04 O.OOOE+00 0.OOOE+00 0.OOOE+00 1.770E+04 RB-88 0.OOOE+00 5.460E+02 2.720E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.920E-05 RB-89 0.OOOE+00 3.520E+02 2.330E+02 0.OOOE+00 0.OOOE+00 O.OOOE+00 3.380E-07 SR-89 4.340E+05-0.OOOE+00 1.250E+/-04 0.OOOE+00 0.OOOE+00 2.420E+06 3.710E+05 SR-90 1.080E+08 0.OOOE+00 6.680E+06 0.OOOE+00 0.OOOE+00 1.650E+07 7.650E+05 SR-91 8.800E+01 0.OOOE+00 3.510E+00 0.OOOE+00 0.OOOE+00 6.070E+04 2.590E+05 SR-92 9.520E+00 0.OOOE+00 4.060E-01 0.OOOE+00 0.OOOE+00 2.740E+04 1.190E+05 Y-90 2.980E+03 0.OOOE+00 8.OOOE+01 0.OOOE+00 0.OOOE+00 2.930E+05 5.590E+05 Y-91M 3.700E-01 0.OOOE+00 1.420E-02 0.OOOE+00 0.OOOE+00 3.200E+03 3.020E+01 Y-91 6.610E+05 0.000E+00 1.770E+04 0.OOOE+00 0.OOOE+00 2.940E+06 4.090E+05 Y-92 1.470E+01 0.OOOE+00 4.290E-01 0.OOOE+00 0.OOOE+00 2.680E+04 1.650E+05 Y-93 1.350E+02 0.OOOE+00 3.720E+00 0.OOOE+00 0.OOOE+00 8.320E+04 5.790E+05

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 276 of 318 2 Gaseous Effluent Pathway Dose Factors INHALATION DOSE FACTORS TEEN Nuclide ZR-95 ZR-97 NB-95 NB-97 MO-99 TC-99M TC-101 RU-103 RU-105 RU-106 RH-103M RH-106 AG-110M SB-122 SB-124 SB-125 TE-125M TE-127M TE-127 TE-129M TE-129 TE-131M TE-131 TE-132 1-130 1-131 1-132 I-133 1-134 1-135 CS-134 CS-136 CS-137 CS-138 Bone 1.460E+05 1.380E+02 1.860E+04 3.140E-01 0.OOOE+00 1.380E-03 5.920E-05 2.100E+03 1.120E+00 9.840E+04 0.000E+00 0.000E+00 1.380E+04 3.100E+03 4.300E+04 7.380E+04 4.880E+03 1.800E+04 2.01 0E+00 1.390E+04 7.1 00E-02 9.840E+01 1.580E-02 3.600E+02 6.240E+03 3.540E+04 1.590E+03 1.220E+04 8.880E+02 3.700E+03 5.020E+05 5.150E+04 6.700E+05 4.660E+02 Liver 4.580E+04 2.720E+01 1.030E+04 7.780E-02 1.690E+02 3.860E-03 8.400E-05 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 1.310E+04 4.11 OE+03 7.940E+02 8.080E+02 2.240E+03 8.160E+03 9.120E-01 6.580E+03 3.380E-02 6.010E+01 8.320E-03 2.900E+02 1.790E+04 4.91 OE+04 4.380E+03 2.050E+04 2.320E+03 9.440E+03 1.130E+06 1.940E+05 8.480E+05 8.560E+02 (mrem/yr per uCi/m 3)

Tbody Thyroid 3.150E+04 0.000E+00 1.260E+01 0.OOOE+00 5.660E+03 0.000E+00 2.840E-02 0.OOOE+00 3.220E+01 0.OOOE+00 4.990E-02 8.240E-04 8.960E+02 4.340E-01 1.240E+04 0.000E+00 0.000E+00 7.990E+03 4.11 OE+04 1.680E+04 1.720E+04 6.670E+02 2.180E+03 4.420E-01 2.250E+03 1.760E-02 4.020E+01 5.040E-03 2.190E+02 7.170E+03 2.640E+04 1.580E+03 6.220E+03 8.400E+02 3.490E+03 5.490E+05 1.370E+05 3.110E+05 4.460E+02 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 0.060E+00 0.OOOE+00 1.070E+03 9.760E+01 7.040E+01 1.400E+03 4.380E+03 1.420E+00 4.580E+03 5.180E-02 7.250E+01 1.240E-02 2.460E+02 1.490E+06 1.460E+07 1.510E+05 2.920E+06 3.950E+04 6.21 0E+05 0.OOE+00 0.OOOE+00 Kidney Lung Gitract 6.740E+04 2.690E+06 1.490E+05 4.120E+01 1.300E+05 6.300E+05 1.000E+04 7.510E+05 9.680E+04 9.120E-02 3.930E+03 2.170E+03 4.110E+02 1.540E+05 2.690E+05 5.760E-02 1.150E+03 6.130E+03 1.520E-03 6.670E+02 8.720E-07 7.430E+03 7.830E+05 1.090E+05 1.410E+00 1.820E+04 9.040E+04 1.900E+05 1.61OE+07 9.600E+05 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 2.500E+04 6.750E+06 2.730E+05 1.550E+03 1.670E+05 2.020E+05 0.000E+00 3.850E+06 3.980E+05 0.000E+00 2.740E+06 9.920E+04 0.000E+00 5.360E+05 7.500E+04 6.540E+04 1.660E+06 1.590E+05 7.280E+00 1.120E+04 8.080E+04 5.190E+04 1.980E+06 4.050E+05 2.660E-01 3.300E+03 1.620E+03 4.390E+02 2.380E+05 6.210E+05 6.180E-02 2.340E+03 1.510E+01 1.950E+03 4.490E+05 4.630E+05 2.750E+04 0.000E+00 9.120E+03 8.400E+04 0.000E+00 6.490E+03 6.920E+03 0.000E+00 1.270E+03 3.590E+04 0.OOOE+00 1.030E+04 3.660E+03 0.OOOE+00 2.040E+01 1.490E+04 0.OOOE+0O 6.950E+03 3.750E+05 1.460E+05 9.760E+03 1.100E+05 1.780E+04 1.090E+04 0.0001H+00

'3.040E+05 0.OOOE+00 6.620E+02 1.21 OE+05 8.480E+03 7.870E+01 2.700E-01

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 277 of 318 2 Gaseous Effluent Pathway Dose Factors Nuclide BA-139 BA-140 BA-141 BA-142 LA-140 LA-142 CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 EU-154 EU-155 W-187 NP-239 Bone i1.340E+00 5.470E+04 i1.420E-01 3.700E-02 4.790E+02 9.600E-01, 2.840E+04 2.660E+02 4.890E+06 1.340E+04 4.300E-02 7.860E+03 7.540E+06 i1.600E+06 i1.200E+01 3.380E+02 Liver' 9.440E-04 6.700E+01 1.060E-04 3.700E-05 2.360E+02 4.250E-01 1.900E+04 1.940E+02 2.020E+06 5.31 OE+03 1.760E-02 8.560E+03 9.840E+05 1.570E+05 9.760E+00 3.190E+01 INHALATION DOSE FACTORS TEEN (mrem/yr per uCi/m 3)

Thody Thyroid 3.900E-02 0.OOOE+00 8.1 3.520E+03 0.OOOE+00 2.

4.740E-03 0.OOOE+00 9.1 2.270E-03 0.OOOE+00 3.

6.260E+01 0.OOOE+00 0.,

1.060E-01 0.OOOE+00 0.(

2.170E+03 0.OOOE+00 8.1 2.160E+01 0.OOOE+00 8.,

2.620E+05 0.OOOE+00 1.

6.620E+02 0.OOOE+00 3.(

2.180E-03 0.OOOE+00 1.(

5.130E+02 0.OOOE+00 5.1 6.880E+05 0.000E+00 4.:

9.680E+04 0.OOOE+00 6.

3.430E+00 0.OOOE+00 0.1 1.770E+01 0.OOOE+00 1.

Kidney Lung GItract 880E-04 6.460E+03 6.450E+03 280E+01 2.030E+06 2.290E+05 84OEr05 3.290E+03 7.460E-04 140E-05 1.910E+03 0.OOOE+00 600E+00 2.140E+05 4.870E+05 OOE+00 1.020E+04 1.200E+04 880E+03 6.140E+05 1,260E+05 640E+01 1.300E+05 2.550E+05 21OE+06 1.340E+07 8.640E+05 090E+03 4.830E+05 2.140E+05 O1OE-02 1.750E+03 2.350E-04 020E+03 3.720E+05 1.820E+05 350E+06 7.300E+06 2.670E+05 120E+05 1.210E+07 4.780E+05 OO0E+00 4.740E+04 1.770E+05 006E+02 6.490E+04 1.320E+05

Rev.

00802 OFFSITE DOSE CALCULATION MANUAL PagRe 27 Pae278 of 318 Gaseous Effluent Pathway Dose Factors INHALATION DOSE FACTORS CHILD (mrem/yr per uCi/m 3)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract H-3 0.OOOE+00 1.120E+03 1.120E+03 1.120E+03 1.120E+03 1.120E+03 1.120E+03 C-14 3.590E+04 6.730E+03 6.730E+03 6.730E+03 6.730E+03 6.730E+03 6.730E+03 NA-24 1.610E+04 1.610E+04 1.610E+04 1.610E+04 1.610E+04 1.610E+04 1.610E+04 P-32 2.600E+06 1.140E+05 9.880E+04 0,000E+00 0.000E+00 0.OOOE+00 4.220E+04 CR-51 0.000E+00 0.OOOE+00 1.540E+02 8.550E+01 2.430E+01 1.700E+04 1.080E+03 MN-54 O.000E+00 4.290E+04 9.510E+03 0.OOOE+00 1.000E+04 1.580E+06 2.290E+04 MN-56 0.000E+00 1.660E+00 3.120E-01 0.000E+00 1.670E+00 1.310E+04 1.230E+05 FE-55 4.740E+04 2.520E+04 7.770E+03 0.000E+00 0.000E+00 1.110E+05 2.870E+03 FE-59 2.070E+04 3.340E+04 1.670E+04 0.000E+00 0.000E+00 1.270E+06 7.070E+04 CO-57 0.000E+00 9.030E+02 1.070E+03 0.OOOE+00 0.OOOE+00 5.070E+05 1.320E+04 CO-58 0.000E+00 1.770E+03 3.160E+03 0.OOOE+00 0.000E+00 1.110E+06 3.440E+04 M0-60 0.000E+00 1.310E+04 2.260E+04 0.000E+00 0.000E+00 7.070E+06 9.620E+04 NI-63 8.21 OE+05 4.630E+04 2.800E+04 0.000E+00 0.000E+00 2.750E+05 6.330E+03 NI-65 2.990E+00 2.960E-01 1.640E-01 0.000E+00 0.000E+00 8.180E+03 8.400E+04 CU-64 0.000E+00 1.990E+00 1.070E+00 0.000E+00 6.030E+00 9.580E+03 3.670E+04 ZN-65 4.260E+04 1.1 30E+05 7.030E+04 0.OOOE+00 7.140E+04 9.950E+05 1.630E+04 ZN-69 6.700E-02 9.660E-02 8.920E-03 0.000E+00 5.850E-02 1.420E+03 9.51 OE+03 BR-82 0.000E+00 0.OOOE+00 2.090E+04 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 BR-83 0.000E+00 0.000E+00 4.740E+02 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 BR-84 0.000E+00 0.000E+00 5.480E+02 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 BR-85 0.OOOE+00 0.000E+00 2.530E+01 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 RB-86 0.OOOE+00 1.980E+05 1.140E+05 0.000E+00 0.000E+00 0.000E+00 7.990E+03 RB-88 0.OOOE+00 5.620E+02 3.660E+02 0.000E+00 0.000E+00 0.000E+00 1.720E+01 RB-89 0.000E+00 3.450E+02 2.900E+02 0.OOOE+00 0.000E+00 0.000E+00 1.890E+00 SR-89 5.990E+05 0.000E+00 1.720E+04 0.000E+00 0.000E+00 2.160E+06 1.670E+05 SR-90 1.010E+08 0.OOOE+00 6.440E+06 0.000E+00 0.OOOE+00 1.480E+07 3.430E+05 SR-91 1.210E+02 0.OOOE+00 4.590E+00 0.OOOE+00 0.000E+00 5.330E+04 1.740E+05 SR-92 1.310E+01 0.OOOE+00 5.250E-01 0.000E+00 0.000E+00 2.400E+04 2.420E+05 Y-90 4.11 OE+03 0.000E+00 1.110E+02 0.OOOE+00 0.OOOE+00 2.620E+05 2.680E+05 Y-91M 5.0702-01 0.OOOE+00 1.840E-02 0.000E+00 0.OOOE+00 2.810E+03 1.720E+03 Y-91 9.140E+05 0.000E+00 2.440E+04 0.000E+00 0.000E+00 2.630E+06 1.840E+05 Y-92 2.040E+01 0.OOOE+00 5.810E-01 0.OOOE+00 0.OOOE+00 2.390E+04 2.390E+05 Y-93 1.860E+02 0.OOOE+00 5.11 OE+00 0.OOOE+00 0.OOOE+00 7.440E+04 3.890E+05 ZR-95 1.900E+05 4.180E+04 3.700E+04 0.000E+00 5.960E+04 2.230E+06 6.11 OE+04 I

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 O T D

E CO MPage 279 of 318 2 Gaseous Effluent Pathway Dose Factors INHALATION DOSE FACTORS CHILD Nuclide ZR-97 NB-95 NB-97 MO-99 TC-99M TC-101 RU-103 RU-105 RU-106 RH-103M RH-106 AG-110M SB-122 SB-124 SB-125 TE-125M TE-127M TE-127 TE-129M TE-129 TE-131M TE-131 TE-132 1-130 1-131 1-132 1-133 1-134 1-135 CS-134 CS-136 CS-137 CS-138 Bone 1.880E+02 2.350E+04 4.290E-01 O.OOOE+00 1.780E-03 8.100E-05 2.790E+03 1.530E+00 1.360E+05 0.OOOE+00 0.OOOE+00 1.690E+04 1440E+03 5.740E+04 9.840E+04 6.730E+03 2.490E+04 2.770E+00 1.920E+04 9.770E-02 1.340E+02 2.170E-02 4.810E+02 8.180E+03 4.810E+04 2.120E+03 1.660E+04 1.170E+03 4.920E+03 6.510E+05 6.510E+04 9.070E+05 6.330E+02 Liver 2.720E+01 9.180E+03 7.700E-02 1,720E+02 3.480E-03, 8.51OE-05 0.000E+00 O.O00E+00 0.000E+00 0.OOOE+00 0.000E+00 1.140E+04 1.980E+03 7.400E+02 7.590E+02 2.330E+03 8.550E+03 9.51 E-0-1 6.850E+03 3.500E-02 5.920E+01 8.440E-03 2.720E+02 1.640E+04 4.81 0E+04 4.070E+03 2.030E+04 2.160E+03 8.730E+03 1.010E+06 1.710E+05 8.250E+05 8.400E+02 (mrem/yr per uCi/m 3)

Tbody Thyroid Kidney 1.600E+01 0.000E+00 3.890E+01 6.550E+03 0.000E+00 8.620E+03 3.600E-02 0.000E+00 8.550E-02 4.260E+01 0.000E+00 3.920E+02 5.770E-02 0.000E+00 5.070E-02 1.080E-03 0.000E+00 1.450E-03 1.070E+03 0.000E+00 7.030E+03 5.550E-01 0.000E+00 1.340E+00 1.690E+04 0.000E+00 1.840E+05 O.O00E+00 O.O00E+00 O.O000E+0 O.O00E+00 O.O00E+00 O.O00E+00 9.140E+03 O.O00E+00 2.120E+04 1.900E+04 4.960E+02 7.180E+02 2.000E+04 1.260E+02 O.000E+00 2.070E+04 9.100E+01 O.000E+00 9.140E+02 1.920E+03 0.000E+00 3.020E+03 6.070E+03 6.360E+04 6.110E-01 1.960E+00 7.070E+00 3.040E+03 6.330E+03 5.030E+04 2.380E-02 7.140E-02 2.570E-01 5.070E+01 9.770E+01 4.000E+02 6.590E-03 1.700E-02 5.880E-02 2.630E+02 3.170E+02 1.840E+03 8.440E+03 1.850E+06 2.450E+04 2.730E+04 1.620E+07 7.880E+04 1.880E+03 1.940E+05 6.250E+03 7.700E+03 3.850E+06 3.380E+04 9.950E+02 5.070E+04 3.300E+03 4.140E+03 7.920F+05 1.340E+04 2.250E+05 O.O00E+00 3.300E+05 1.160E+05 O.O00E+00 9.550E+04 1.280E+05 0.000E+00 2.820E+05 5.550E+02 0.000E+00 6.220E+02 Lung Gitract 1.130E+05 3.510E+05 6.140E+05 3.700E+04 3.420E+03 2.780E+04 1.350E+05 1.270E+05 9.51 0E+02 4.81 0E+03 5.850E+02 1.630E+01 6.620E+05 4.480E+04 1.590E+04 9.950E+04 1.430E+07 4.290E+05 0.000E+00 0.000E+00 0.000E+00 0.000E+00 5.480E+06 1.000E+05 7.730E+04 9.360E+04 3.240E+06 1.640E+05 2.320E+06 4.030E+04 4.770E+05 3.380E+04 1.480E+06 7.140E+04 1.000E+04 5.620E+04 1.760E+06 1.820E+05 2.930E+03 2.550E+04

.2.060E+05 3.080E+05 2.050E+03 1.330E+03 3.770E+05 1.380E+05 O.000E+00 5.110E+03 O.O00E+00 2.840E+03 O.000E+00 3.200E+03 O.O00E+00 5.480E+03 O.000E+00 9.550E+02 O.O00E+00 4.440E+03 1.210E+05 3.850E+03 1.450E+04 4.180E+03 1.040E+05 3.620E+03 6.810E+01 2.700E+02

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 280 of 318 2 Gaseous Effluent Pathway Dose Factors INHALATION DOSE FACTORS CHILD (mrem/yr per uCi/m3)

Nuclide Bone Liver Thody Thyroid Kidney Lung Gltract BA-139 BA-140 BA-141 BA-142 LA-140 LA-142 CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 EU-154 EU-155 W-187 NP-239 1.840E+00 9.840E-04 5.370E-02 7.400E+04 6.480E+01 4.330E+03 1.960E-01 1.090E-04 6.360E-03 5.OOOE-02 3.600E-05 2.790E-03 6.440E+02 2.250E+02 7.550E+01 1.300E+00 4.I11OE-01 1.290E-01 3.920E+04 1.950E+04 2.900E+03 3.660E+02 1.990E+02 2.870E+01 6.770E+06 2.120E+06 3.610E+05 1.850E+04 5.550E+03 9.140E+02 5.960E-02 1.850E-02 3.OOOE-03 1.080E+04 8.730E+03 6.810OE+02 1.O10E+07 9.210E+05 8.400E+05 2.070E+06 I1.500E+05 I1.180E+05 1.630Ei-01 9.660E+00 4.330E+00 4.700E+02 3.340E+01 2.350E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 8.620E-04 5.770E+03 2.110E+01 1.740E+06 9.470E-05 2.920E+03 2.910E-05 1.640E+03 0.OOOE+00 1.830E+05 0.OOOE+00 8.700E+03 8.550E+03 5.440E+05 8.360E+01 1.150E+05

1. 170E+06 1.200E+07 3.OOOE+03 4.330E+05 9.770E-03 1.570E+03 4.810E+03 3.280E+05 4.030E+06 6.140E+06 5.590E+05 1.030E+06 0.OOOE+00 4.11 OE+04 9.730E+01 5.810E+04 5.770E+04 1.020E+05 2.750E+02 2.740E+00 2.260E+05 7.590E+04

&.660E+04 1.270E+05 3.890E+05 9.730E+04 I1.970E+02 8.210E+04 1.100E+05 1.990E+05

9. 1 OOE+04 6.400E+04

Rev.

00802 OFFSITE DOSE CALCULATION MANUAL Page 281 of 318 Gaseous Effluent Pathway Dose Factors INHALATION DOSE FACTORS INFANT (rnrem/yr per uCi/m 3)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract H-3 0.OOOE+00 6.470E+02 6.470E+02 6.470E+02 6.470E+02 6.470E+02 6.470E+02 C-14 2.650E+04 5.310E+03 5.310E+03 5.310E+03 5.310E+03 5.310E+03 5.310E+03 NA-24 1.060E+04 1.060E+04 1.060E+04 1.060E+04 1.060E+04 1.060E+04 1.060E+04 P-32 2.030E+06 1.120E+05 7.740E+04 0.OOOE+00 0.OOE+00 0.OOOE+00 1.610E+04 CR-51 0.OOOE+00 0.OOOE+00 8.950E+01 5.750E+01 1.320E+01 1.280E+04 3.570E+02 MN-54 0.OOOE÷00 2.530E+04 4.980E+03 0.000E+00 4.980E+03 1.OOOE+06 7.060E+03 MN-56 0.OOOE+00 l.540E+00 2.210E-01 0.OOOE+00 1.100E+00 1.250E+04 7.170E+04 FE-55 1.970E+04 1.170E+04 3.330E+03 0.000E+00 0.OOOE+00 8.690E+04 1.090E+03 FE-59 1.360E+04 2.350E+04 9.480E+03 0.OOOE+00 0.OOOE+00 1.020E+06 2.480E+04 CO-57 0.OOOE+00 6.510E+02 6.410E+02 0.OOOE+00 0.OOOE+00 3.790E+05 4.860E+03 CO-58 0.OOOE+00 1.220E+03 1.820E+03 0.OOOE+00 0.OOOE+00 7.770E+05 1.110E+04 CO-60 0.OOOE+00 8.020E+03 1.180E+04 0.000E+00 0.OOOE+00 4.510E+06 3.190E+04 NI-63 3.390E+05 2.040E+04 1.160E+04 0.OOOE+00 0.OOOE+00 2.090E+05 2.420E+03 NI-65 2.390E+00 2.840E-01 1.230E-01 0.OOOE+00 0.OOOE+00 8.120E+03 5.01OE+04 CU-64 O.OOOE+00 1.880E+00 7.740E-01 0.OOOE+00 3.980E+00 9.300E+03 1.500E+04 ZN-65 1.930E+04 6.260E+04 3.110E+04 0.OOOE+00 3.250E+04 6.470E+05 5.140E+04 ZN-69 5.390E-02 9.670E-02 7.180E-03 0.OOOE+00 4.020E-02 1.470E+03 1.320E+04 BR-82 O.OOOE+00 0.OOOE+00 1.330E+04 o.oooE+oo 0.OOOE+00 O.OOOE+00 0.OOOE+00 BR-83 0.OOOE+00 0.OOOE+00 3.81 OE+02 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-84 0.OOOE+00 0.OOOE+00 4.OOOE+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-85 0.OOOE+00 0.000E+00 2.040E+01 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 RB-86 0.OOOE+00 1.900E+05 8.820E+04 0.OOOE+00 0.OOOE+00 O.OOOE+00 3.040E+03 RB-88 0.OOOE+00 5.570E+02 2.870E+02 0.OOOE+00 0.OOOE+00 O.OOOE+00 3.390E+02 RB-89 0.OOOE+00 3.21 OE+02 2.060E+02.

0.OOOE+00 0.OOOE+00 0.000E+00 6.820E+01 SR-89 3.980E+05 O.OOOE+00 1.140E+04 0.00OE+00 0.OOOE+00 2.030E+06 6.400E+04 SR-90 4.090E+07 0.OOOE+00 2.590E+06 0.OOOE+00 0.OOOE+00 1.120E+07 1.310E+05 SR-91 9.560E+01 0.OOOE+00 3.460E+00 0.OOOE+00 0.OOOE+00 5.260E+04 7.340E+04 SR-92 1.050E+01 O.OOOE+00 3.910E-01 0.OOOE+00 0.OOOE+00 2.380E+04 1.400E+05 Y-90 3.290E+03 0.OOOE+00 8.820E+01 0.000E+00 0.OOOE+00 2.690E+05 1.040E+05 Y-91M 4.070E-01 o.o60E+00 1.390E-02 0.OOOE+00 0.OOOE+00 2.790E+03 2.350E+03 Y-91 5.880E+05 0.0OE+00 1.570E+04 0.OOOE+00 0.OOOE+00 2.450E+06 7.030E+04 Y-92 1.640E+01 0.OOOE+00 4.610E-01 0.OOOE+00 0.OOOE+00 2.450E+04 1.270E+05 Y-93 1.500E+02 0.OOOE+00 4.070E+00 0.OOOE+00 0.OOOE+00 7.640E+04 1.670E+05

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 282 of 318 2 Gaseous Effluent Pathway Dose Factors INHALATION DOSE FACTORS INFANT (mrem/yr per uCi/m 3)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract ZR-95 1.150E+05 2.790E+04 2.030E+04 0.OOOE+00 3.11OE+04 1.750E+06 2.170E+04 ZR-97 1.500E+02 2.560E+01 1.170E+01 0.OOOE+00 2.590E+01 1.100E+05 1.400E+05 NB-95 1.570E+04 6.430E+03 3.780E+03 0.OOOE+00 4.720E+03 4.790E+05 1.270E+04 NB-97 3.420E-01 7.290E-02 2.630E-02 0.OOOE+00 5.700E-02 3.320E+03 2.690E+04 MO-99 0.OOOE+00 1.650E+02 3.230E+01 0.OOOE+00 2.650E+02 1.350E+05 4.870E+04 TC-99M 1.400E-03 2.880E-03 3.720E-02 0.OOOE+00 3.11 OE-02 8.11OE+02 2.030E+03 TC-101 6.510E-05 8.230E-05 8.120E-04 0.OOOE+00 9.790E-04 5.840E+02 8.440E+02 RU-103 2.020E+03 0.OOOE+00 6.790E+02 0.OOOE+00 4.240E+03 5.520E+05 1.610E+04 RU-105 1.220E+00 O.OOOE+00 4.100E-01 O.OOOE+00 8.990E-01 1.570E+04 4.840E+04 RU-106 8.680E+04 0.OOOE+00 1.090E+04 O.OOOE+00 1.070E+05 1.160E+07 1.640E+05 RH-103M O.OOOE+00 O.OOOE+00 O.OOOE+00 O.000E+00 0.OOOE+00 O.OOOE+00 O.OOOE+00 RH-106 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.000E+00 0.OOOE+00 AG-110M 9.980E+03 7.220E+03 5.OOOE+03 0.OOOE+00 1.090E+04 3.670E+06 3.300E+04 SB-122 5.430E+02 7.200E+02 7.200E+03 1.880E+02 2.720E+02 2.930E+04 3.540E+04 SB-124 3.790E+04 5.560E+02 1.200E+04 1010E+02 0.OOOE+00 2.650E+06 5.91OE+04 SB-125 5.170E+04 4.770E+02 1.090E+04 6.230E+01 0.OOOE+00 1.640E+06 1.470E+04 TE-125M 4.760E+03 1.990E+03 6.580E+02 1.620E+03 O.OOOE+00 4.470E+05 1.290E+04 TE-127M 1.670E+04 6.900E+03 2.070E+03 4.870E+03 3.750E+04 1.310E+06 2.730E+04 TE-127 2.230E+00 9.530E-01 4.890E-01 1.850E+00 4.860E+00 1.030E+04 2.440E+04 TE-129M 1.410E+04 6.090E+03 2.230E+03 5.470E+03 3.180E+04 1.680E+06 6.900E+04 TE-129 7.880E-02 3.470E-02 1.880E-02 6.750E-02 1.750E-01 3.OOOE+03 2.630E+04 TE-131M 1.070E+02 5.500E+01 3.630E+01 8.930E+01 2.650E+02 1.990E+05 1.190E+05 TE-1 31 1.740E-02 8.220E-03 5.OOOE-03 1.580E-02 3.990E-02 2.060E+03 8.220E+03 TE-1 32 3.720E+02 2.370E+02 1.760E+02 2.790E+02 1.030E+03 3.400E+05 4.41 OE+04 1-130 6.360E+03 1.390E+04 5.570E+03 1.600E+06 1.530E+04 0.OOOE+00 1.990E+03 1-131 3.790E+04 4.440E+04 1.960E+04 1.480E+07 5.180E+04 0.OOOE+00 1.060E+03 I-132 1.690E+03 3.540E+03 1.260E+03 1.690E+05 3.950E+03 0.OOOE+00 1.900E+03 1-133 1.320E+04 1.920E+04 5.600E+03 3.560E+06 2.240E+04 0.OOOE+00 2.160E+03 I-134 9.210E+02 1.880E+03 6.650E+02 4.450E+04 2.090E+03 0.OOOE+00 1.290E+03 1-135 3.860E+03 7.600E+03 2.770E+03 6.960E+05 8.470E+03 0.OOOE+00 1.830E+03 CS-134 3.960E+05 7.030E+05 7.450E+04 0.000E+00 1.900E+05 7.970E+04 1.330E+03 CS-136 4.830E+04 1.350E+05 5.290E+04 0.OOOE+00 5.640E+04 1.180E+04 1.430E+03 CS-137 5.490E+05 6.120E+05 4.550E+04 0.OOOE+00 1.720E+05 7.130E+04 1.330E+03 CS-138 5.050E+02 7.81 OE+02 3.980E+02 0.OOOE+00 4.1 OOE+02 6.540E+01 8.760E+02

D SIRev.

00802 O

E DOSE CALCULATION MANUAL Page 283 of 318 2 Gaseous Effluent Pathway Dose Factors INHALATION DOSE FACTORS INFANT (mrem/yr per uCi/m 3)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract BA-139 1.480E+00 9.840E-04 4.300E-02 O.OOOE+00 5.920E-04 5.950E+03 5.100E+04 BA-140 5.600E+04 5.600E+01 2.900E+03 O.OOOE+00 1.340E+/-01 1.600E+06 3.840E+04 BA-141 1.570E-01 1.080E-04 4.970E-03 O.OOOE+OO 6.500E-05 2.970E+03 4.750E+03 BA-142 3.980E-02 3.300E-05 1.960E-03 O.OOOE+00 1.900E-05 1.550E+03 6.930E+02 LA-140 5.050E+02 2.OOOE+02 5.150E+01 O.OOOE+00 O.OOOE+00 1.680E+05 8.480E+04 LA-142 1.030E+00 3.770E-01 9.040E-02 O.OOOE+00 O.OOOE+00 8.220E+03 5.950E+04 CE-141 2.770E+04 1.670E+04 1.990E+03 O.OOOE+00 5.250E+03 5.170E+05 2.160E+04 CE-143 2.930E+02 1.930E+02 2.210E+01 O.OOOE+00 5.640E+01 1.160E+05 4.970E+04 CE-144 3.190E+06 1.210E+06 1.760E+05 O.OOOE+00 5.380E+05 9.840E+06 1.480E+05 PR-143 1.400E+04 5.240E+03 6.990E+02 O.OOOE+00 1.970E+03 4.330E+05 3.720E+04 PR-144 4.790E-02 1.850E-02 2.410E-03 O.OOOE+00 6.720E-03 1.610E+03 4.280E+03 ND-147 7.940E+03 8.130E+03 5.000E+02 O.OOOE+00 3.150E+03 3.220E+05 3.120E+04 EU-154 4.140E+06 4.840E+05 3.430E+05 O.OOOE+00 1.540E+06 4.270E+06 3.980E+04 EU-155 8.360E+05 8.010E+04 4.840E+04 O.OOOE+00 2.210E+05 7.280E+05 7.270E+04

  • W-187 1.300E+01 9.020E+00 3.120E+00 O.OOOE+00 O.OOOE+00 3.960E+04 3.560E+04 NP-239 3.710E+02 3.320E+01 1.880E+01 O.OOOE+00 6.620E+01 5.950E+04 2.490E+04

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 284 of 318 2 Gaseous Effluent Pathway Dose Factors GRASS-COW-MILK DOSE FACTORS ADULT (i 2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract H-3 C-14 NA-24 P-32 CR-51 MN-54 MN-56 FE-55 FE-59 CO-57 CO-58 CO-60 NI-63 NI-65 CU-64 ZN-65 ZN-69 BR-82 BR-83 BR-84 BR-85 RB-86 RB-88 RB-89 SR-89 SR-90 SR-91 SR-92 O.OOOE+00 3.630E+05 2.540E+06 1.710E+10 O.OOOE+O0 O.OOOE+oo O.OOOE+O0 2.51 OE+07 2.980E+07 O.OOOE+00 O.OOOE+00 O.OOOE+00 6.730E+09 3.700E-01 O.OOOE+00 1.370E+09 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.450E+09 4.680E+10 3.130E+04 4.890E-01 7.630E+02 7.260E+04 2.540E+06 1.060E+09 O.OOOE+00 8.400E+06 4.230E-03 1.730E+07 7.OOOE+07 1.280E+06 4.720E+06 1.640E+07 4.660E+08 4.810E-02 2.410E+04 4.360E+09 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 2.590E+09 O.OOOE+00 O.OOOE+00 0.000E+06 O.OOOE+00 O.OOOE+00 O.OOOE+00 7.630E+02 7.630E+02 7.630E+02 7.260E+04 7.260E+04 7.260E+04 2.540E+06 2.540E+06 2.540E+06 6.600E+08 O.OOOE+00 O.OOOE+00 2.860E+04 1.710E+04 6.300E+03 1.600E+06 O.OOOE+00 2.500E+06 7.510E-04 0.OOOE+00 5.380E-03 4.040E+06 O.OOOE+00 0.00mE+00 2.680E+07 O.OOOE+00 O.OOOE+00 2.130E+06 O.OOOE+00 O.OOOE+00 1.060E+07 O.OOOE+00 O.OOOE+00 3.620E+07 O.OOOE+00 O.OOOE+00 2.260E+08 0.OOOE+00 0.OOOE+00 2.190E-02 O.OOOE+00 O.OOOE+00 1.130E+04 O.OOOE+00 6.080E+04 1.970E+09 O.OOOE+00 2.920E+09 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.210E+09 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 0.000E+00 O.OOOE+00 6.000E+00 0.000E+00 4.160E+07 O.OOOE+00 O.OOOE+00 1.150E+10 O.OOOE+00 O.OOOE+00 1.270E+03 O.OOOE+00 O.OOOE-+00 2.11OE-02 O.OOOE+00 O.OOOE+00 7.630E+02 7.260E+04 2.540E+06 O:OOOE+OO 3.800E+04 O.OOOE+OO O.OOOE+OO 9.670E+06 1.950E+07 O.OOOE+OO O.OOOE+OO O.OOOE+OO 0.OOOE+0O O.OOOE+0O O.OOOE+00 O.OOOE+00 O.OOOE+OO O.OOOE+OO O.OOOE+OO O.OOOE+OO O.OOOE+OO O.OOOE+O0 O.OOOE+0O O.OOOE+OO O.OOOE+OO 0.OOOE+00 O.OOOE+00 0.OOOE+00 7.630E+02 7.260E+04 2.540E+06 1.920E+09 7.200E+06 2.570E+07 1.350E-01 9.950E+06 2.330E+08 3.250E+07 9.570E+07 3.080E+08 9.730E+07 1.220E+00 2.050E+06 2.750E+09 O.OOOE+OO O.OOOE+00 O.OOOE+O0 O.OOOE+00 O.OOOE+OO 5.11 OE+08 O.OOOE+0O O.OOOE+0O 2.330 E+08 1.350E+69 1.490E+05 9.680E+00

Rev.

00802 OFFSITE DOSE CALCULATION MANUAL Page 285 of 318 Gaseous Effluent Pathway Dose Factors GRASS-COW-MILK DOSE FACTORS ADULT (M 2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract Y-90 7.070E+01 0.OOOE+00 1.900E+00 0.OOOE+00 0:OOOE+00 0.OOOE+00 7.500E+05 Y-91M 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 Y-91 8.600Et03 0.000E+00 2.300E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.730E+06 Y-92 5.420E-05 0.OOOE+00 1.580E-06 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.490E-01 Y-93 2.330E-01 0.OOOE+00 6.430E-03 O.OOOE+00 0.OOOE+00 0.060E+00 7.390E+03 ZR-95 9.460E+02 3.030E+02 2.050E+02 0.OOOE+00 4.760E+02 0.OOOE+00 9.620E+05 ZR-97 4.260E-01 8.590E702 3.930E-02 0.OOOE+00 1.300E-01 0.OOOE+00 2.660E+04 NB-95 8.250E+04 4.590E+04 2.470E+04 0.OOOE+00 4.540E+04 0.OOOE+00 2.790E+08 NB-97 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.470E-09 MO-99 0.OOOE+00 2.520E+07 4.800E+06 0.OOOE+00 5.720E+07 0.OOOE+00 5.850E+07 TC-99M 3.250E+00 9.190E+00 1.170E+02 0.OOOE+00 1.400E+02 4.500E+00 5.440E+03 TC-101 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RU-103 1.020E+03 0.OOOE+00 4.390E+02 0.OOOE+00 3.890E+03 0.OOOE+00 1.190E+05 RU-105 8.570E-04 O.OOOE+00 3.380E-04 0.OOOE+00 1.11OE-02 0.OOOE+00 5.240E-01 RU-106 2.040E+04 0.OOOE+00 2.580E+03 0.OOOE+00 3.940E+04 0.OOOE+00 1.320E+06 RH-103M 0.OOOE+00 0.006E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RH-106 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 AG-110M 5.830E+07 5.390E+07 3.200E+07 0.OOOE+00 1.060E+08 0.OOOE+00 2.200E+10 SB-122 6.010E+05 6.270E+05 7.590E+06 9.960E+04.

2.960E+05.

1.290E+05 7.470E+07 SB-124 8.580E+08 1.620E+07 3.400E+08 2.080E+/-06 0.OOOE+00 6.680E+08 2.440E+10 SB-125 6.810E+08 7.610E+06 1.620E+08 6.930E+05 0.OOOE+00 5.250E+08 7.500E+09 TE-125M 1.630E+07 5.900E+06 2.180E+06 4.900E+06 6.630E+07 0.OOOE+00 6.500E+07 TE-127M 4.580E+07 1.640E+07 5.580E+06 1.170E+07 1.860E+08 0.OOOE+00 1.540E+08 TE-127 6.720E+02 2.410E+02 1.450E+02 4.980E+02 2.740E+03 0.OOOE+00

-5.300E+04 TE-129M 6.040E+07 2.250E+07 9.570E+06 2.080E+07 2.520E+08 0.OOOE+00 3.040E+08 TE-129 0.000E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 TE-131M 3.610E+05 1.770E+05 1.470E+05 2.800E+05 1.790E+06 0.OOOE+00 1.750E+07 TE-131 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 TE-132 2.390E+06 1.550E+06 1.450E+06 1.710E+06 1.490E+07 0.OOOE+00 7.320E+07 1-130 4.260E+05 1.260E+06 4.960E+05 1.070E+08 1.960E+06 0.OOOE+00 1.080E+06 1-131 2.960E+08 4.240E+08 2.430E+08 1.390E+11 7.270E+08 0.006E+00 1.120E+08 1-132 1.640E-01 4.370E-01 1.530E-01 1.530E+01 6.970E-01 0.OOOE+00 8.220E-02 1-133 3.970E+06 6.900E+06 2.100E+06 1.010E+09 1.200E+07 0.OOOE+00 6.200E+06

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 286 of 318 Gaseous Effluent Pathway Dose Factors GRASS-COW-MILK DOSE FACTORS ADULT (M2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Thody Thyroid Kidney Lung Gitract 1-134 1-135 CS-1 34 CS-136 CS-137 CS-138 BA-139 BA-140 BA-141 BA-142 LA-140 LA-142 CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 EU-154 EU-155 W-187 NP-239 O.OOOE+00 1.390E+04 5.650E+09 2.610E+08 7.380E+09 0.OOOE+00 4.700E-08 2.690E+07 O.OOOE+00 O.OOOE+00 4.490E+00 0.OOOE+00 4.840E+03 4.190E+01 3.580E+05 1.590E+02 0.OOOE+00 9.420E+01 2.370Ei-04 3.300E+03 6.560E+03 3.660E+00 0.OOOE+O0 0.OOOE+00 3.630E+04 1.340E+04 1.340E+10 1.100E+10 1.030E+09 7.420E+08 1.010E+10 6.610E+09 0.OOOE+00 0.OOOE+00 0.OOOE+0O 1.380E-09 3.380E+04 I1.760E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.260E+00 5.970E-01 O.OOOE+00 0.OOOE+00 3.270E+03 3.710OE+02 3.090E+04 3.420E+00 1.500E+05 I1.920E+04 6.370E+01 7.880E+00 0.OOOE+00 0.OOOE+O0 1.090E+02 6.520E+00 2.910OE+03 2.070E+03 4.680E+02 3.020E+02 5.480E+03 1.920E+03 3.600E-01 1.980E-01 0.OOOE+00 2.400E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.830E+04 0.OOOE+00 4.350E+09 I1.440E+09 5.740E+08 7.870E+07 3.430E+09

1. 140E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00
1. 1 50E+04 I1.930E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.520E+03 0.OOOE+00 I1.360E+01 0.OOOE+00 8.870E+04 0.OOOE+00 3.680E+01 0.OOOE+00 0.OOOE+0O 0.OOOE+00 6.370E+01 O.OOOE+00 1.390E+04 0.OOOE+O0 2.160E+03 0.OOOE+00 O.OOOE+00 0.OOOE+00 1.120E+00 0.OOOE+00 0.OOOE+00 4.1 OOE+04 2.350E+08 1.170E+08 1.950E+08 0.OOOE+00 8.340E-08 5.540E+07 0.OOOE+00 0.OOOE+00 1.660E+05 3.030E-08 1.250E+07
1. 160E+06 1.21 OE+08 6.960E+05 0.OOOE+00 5.230E+05 2.11 OE+06 3.680E+05 1.800E+06 7.390E+04

DRev.

00802 OFFSITE DOSE CALCULATION MANUAL Page 287 of 318 2 Gaseous Effluent Pathway Dose Factors GRASS-COW-MILK DOSE FACTORS TEEN (M 2 *mrem/yr per uCi/sec)

Nuclide Bone H-3 C-14 NA-24 P-32 CR-51 MN-54 MN-56 FE-55 FE-59 CO-57 CO-58 CO-60 NI-63 NI-65 CU-64 ZN-65 ZN-69"

,BR-82 BR-83 BR-84 BR-85 RB-86 RB-88 RB-89 SR-89 SR-90 SR-91 SR-92 Y-90 Y-91M Y-91 Y-92 Y-93 0.OOOE+00 6.700E+05 4.440E+06 3.150E+10 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.450E+07 5.200E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.180E+10 6.780E-01 0.OOOE+00 2.11 OE+09 0.OOOE+00 0.OOOE+O0 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.670E+09 6.610OE+10 5.750E+04 8.950E-01 1.300E+02 0.OOOE+00 1.580E+04 1.000Eý04 4.300E-01 Liver Tbody 9.940E+02 9.940E+02 1.340E+05 1.340E+05 4.440E+06 4.440E+06 1.950E+09 1.220E+09 0.OOOE+00 5.OOOE+04 1.400E+07 2.780E+06 7.510E-03 1.330E-03 3.160E+07 7.360E+06 1.210E+08 4.680E+07 2.250E+06 3.760E+06 7.950E+06 1.830E+07 2.780E+07 6.260E+07 8.350E+08 4.01 OE+08 8.660E-02 3.940E-02 4.290E+04 2.020E+04 7.31 OE+09 3.41 OE+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0O0O0E+00 0.O00E+00 O:OOOE+00 4.730E+09 2.220E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.660E+07 0.OOOE+00 1.630E+10 0.OOOE+00 2.290E+03 0.OOOE+00 3.810E-02 0.OOOE+00 3.500E+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 4.240E+02 0.OOOE+00 2.900E-06 0.OOOE+00 1.180E-02 Thyroid Kidney 9.940E+02 1.340E+05 4.440E+06 0.OOOE+00 2.780E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.940E+02 1.340E+05 4.440E+06 0.OOOE+00 1.100E+04 4.170E+06 9.500E-03 0.OOOE+00 0.OOOE+O0 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 1.090E+05 4.680E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+/-00 0.OOOE+00 0-0O0E+00 0.OOOE+00 0.OOOE+00 Lung 9.940E+02 1.340E+05 4.440E+06 0.OOOE+00

.7.130E+04 0.OOOE+00 0.000E+00 2.OOOE+07 3.820E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00

  • .OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 Gitract 9.940E+02 1.340E+05 4.440E+06 2.650E+09 8.400E+06 2.870E+07 4.940E-01 1.370E+07 2.870E+08 4.190E+07 1.100E+08 3.620E+08 1.330E+08 4.700E+00 3.330E+06 3.1 OOE+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000t+00 7.OOOE+08 0.OOOE+00 0.OOOE+00 3.180E+08 1.860E+09 2.610OE+05 2.280E+01 1.070E+06 0.OOOE+00 6.480E+06 2.750E+00 1.310OE+04

Rev.

00802 OFFSITE DOSE CALCULATION MANUAL Page2.

o38 Pae288 of 318 Gaseous Effluent Pathway Dose Factors GRASS-COW-MILK DOSE FACTORS TEEN (M2 *mrem/yr per uCi/sec)

Thody Thyroid Nucilde Bone Liver Kidney Lung Gitract ZR-95 ZR-97 NB-95 NB-97 MO-99 TC-99M TC-101 RU-103 RU-1 05 RU-1 06 RH-103M RH-106 AG-110M SB-122 SB-124 SB-125 TE-125M TE-127M TE-127 TE-129M TE-129 TE-131M TE-131 TE-132 1-130 1-131 1-132 1-133 1-134 1-135 CS-134 CS-136 CS-137 CS-1 38 1.650E+03 7.750E-01 1.41 OE+05 O.OOOE+00 O.OOOE+00 5.640E+00 0.OOOE+00 1.81 OE+03 1.570E-03 3.750E+04 0.OOOE+00 0.000E+00 9.630E+07 7.760E+05 1.530E+09 1.220E+09 3.OOOE+07 8.440E+07 1.240E+03 1.11OE+08 0.OOOE+00 6.570E+05 0.OOOE+00 4.280E+06 7.490E+05 5.380E+08 2.900E-01 7.240E+06 0.OOOE+00 2.470E+04 9.810E+09 4.450E+08 1.340E+10 0.OOOE+00 5.220E+02 1.530E-01 7.800E+04 0.OOOE+00 4.560E+07 1.570E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.000E+00 0.OOOE+00 9.11 OE+07 8.090E+05 2.820E+07 1.330E+07 1.080E+07 2.990E+07 4.41 OE+02 4.100E+07 0.OOOE+00 3.150E+05 0.OOOE+00 2.71 0E+06 2.170E+06 7.530E+08 7.590E-01 1.230E+07 0.OOOE+00 6.350E+04 2.310E+10 1.750E+09 1.780E+10 0.000E+00 3.590E+02 O.OOOE+00 7.670E+02 7.060E-02 O.O00E+00 2.320E-01 4.300E+04 0.O00E+00 7.570E+04 0.000E+00 0.000E+00 0.OOOE+00 8.690E+06 0.000E+00 1.040E+08 2.040E+02 0.000E+00 2.340E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.750E+02 0.OOOE+00 6.400E+03 6.080E-04 0.OOOE+00 1.970E-02 4.730E+03 0.000E+00 7.230E+04 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 5.540E+07 0.OOOE+00 1.740E+08 9.800E+06 1.290E+05 3.820E+05 5.970E+08 3.470E+06 0.OOOE+00 2.850E+08 1.160E+06 0.000E+00 4.020E+06 8.390E+06 0.000E+00 1.000E+07 2.010E+07 3.420E+08 2.680E+02 8.590E+02 5.040E+03 1.750E+07 3.570E+07 4.620E+08 0.OOOE+00 0.OOOE+00 1.670E-09 2.630E+05 4.740E+05 3.290E+06 OO00E+00 O.OOOE+00 O.OOOE+00 2.550E+06 2.860E+06 2.600E+07 8.660E+05 1.770E+08 3.340E+06 4.040E+08 2.200E+l 1 1.300E+09 2.720E-01 2.560E+01 1.200E+00 3.750E+06 1.720E+09 2.150E+07 O.OOOE+00 O.O00E+00 0.O00E+00 2.350E+04 4.080E+06 1.000E+05 1.070E+10 O.OOOE+00 7.340E+09 1.180E+09 O.OOOE+00 9.530E+08 6.200E+09 O.000E+00 6.060E+09 0.000E+00 0.000E+00 0.000E+00 O.000E+00 1.200E+06 O.OOOE+00 4.150E+04 O.OOOE+00 3.340E+08 O.OOOE+00 6.340E-08 O.OOOE+00 8.160E+07 8.730E+00 1.030E+04 0.OOOE+00 0.OOOE+00 0.000E+00 1.520E+05 O.OOOE+00 1.260E+00 O.OOOE+O0 1.800E+06 0.OOOE+00 0.OOOE+00 OO.00E+00 O.000E+00 O.000E+00 2.560E+10 1.660E+05 9.640E+07 1.340E+09 3.080E+10 1.070E+09 9.480E+09 O.OOOE+00 8.860E+07 O.OOOE+00 2.1 OOE+08 0.OOOE+00 9.610E+04 O.OOOE+00 4.150E+08 O.OOOE+00 2.180E-09 O.000E+00 2.530E+07 0.OOOE+00 0.OOOE+00 0.000E+00 8.580E+07 OO00E+00 1.670E+06 O.000E+00 1.490E+08 O.OOOE+00 3.310E-01 O.OOOE+00 9.300E+06 O.000E+00 O.OOOE+00 O.OOOE+00 7.030E+04 2.800E+09 2.870E+08 1.500E+08 1.41 OE+08 2.350E+09 2.530E+08 O.OOOE+00 O.O00E+00

OFFSITE DOSE CALCULATION MANUAL, Rev.

00802 C

MPage 289 of 318 2 Gaseous Effluent Pathway Dose Factors GRASS-COW-MILK DOSE FACTORS TEEN (M2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid

'Kidney Lung Gitract BA-139 BA-140 BA-141 BA-142 LA-140 LA-142 CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 EU-154 EU-155 W-187 NP-239 8.690E&08 4.850E+07 O.OOOE+00 O.OOOE+00 8.060E+OO O.OOOE+00 8.870E+03 7.690E+01 6.580E+05 2.920E+02 O.OOOE+00 1.81 OE+02 3.920E+04 8.600E+03 1.200E+04 6.990E+00 O.OOOE+00 2.530E-09 5.950E+04 3.130E+06 0.000E+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 3.960E+00 1.050E+00 O.OOOE+00 O.OOOE+00 5.920E+03 6.810E+02 5.600E+04 6.250E+00 2.720E+05 3.540E+04 1.170E+02 1.450E+01 O.OOOE+00 O.OOOE+00 1.970E+02 1.180E+01 5.060E+03 3.570E+03 8.310E+02 5.140E+02 9.780E+03 3.430E+03 6.590E-01 3.660E-01 O.OOOE+00 O.OOOE+00 0.OOOE+00 2.020E+04 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 2.790E+03 O.OOOE+00 2.510E+01 O.OOOE+00 1.630E+05 O.OOOE+00 6.770E+01 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.160E+02 O.OOOE+00 2.260E+04 O.OOOE+00 3.250E+03 O.OOOE+00 O.OOOE+00 O.OOOE+00 2.070E+00 O.OOOE+00 4.OOOE+04 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 7.750E-07 7.490E+07 O.OOOE+00 O.OOOE+00 2.270E+05 2.230E-07 1.690E+07 1.680E+06 1.660E+08 9.61 OE+05 O.OOOE+00 7.11 OE+05 2.670E+06 4.760E+06 2.650E+06 1.060E+05

SDATRev.

00802 EDOSE CALCULATION MANUAL Page 290 of 318 2 Gaseous Effluent Pathway Dose Factors GRASS-COW-MILK DOSE FACTORS CHILD (M2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract H-3 0.000E+00 1.570E+03 1.570E+03 1.570E+03 1.570E+03 1.570E+03 1.570E+03 C-14 1.650E+06 3.290E+05 3.290E+05 3.290E+05 3.290E+05 3.290E+05 3.290E+05 NA-24 9.230E+06 9.230E+06 9.230E+06 9.230E+06 9.230E+06 9.230E+06 9.230E+06 P-32 7.770E+10 3.640E+09 3.000E+09 0.000E+00 0.000E+00 0.OOOE+00 2.150E+09 CR-51 0.OOOE+00 0.OOOE+00 1.020E+05 5.660E+04 1.550E+04 1.030E+05 5.41 OE+06 MN-54 0.OOOE+00 2.090E+07 5.580E+06 0.000E+00 5.870E+06 0.000E+00 1.760E+07 MN-56 0.OOOE+00 1.310E-02 2.950E-03 0.000E+00 1.580E-02 0.OOOE+00 1.900E+00 FE-55 1.120E+08 5.930E+07 1.840E+07 0.000E+00 0.OOOE+00 3.350E+07 1.100E+07 FE-59 1.200E+08 1.950E+08 9.710E+07 0.000E+00 0.000E+00 5.650E+07 2.030E+08 CO-57 0.OOOE+00 3.840E+06 7.770E+06 0.000E+00 0.000E+00 0.OOOE+00 3.140E+07 CO-58 0.OOOE+00 1.210E+07 3.720E+07 0.000E+00 0.000E+00 0.000E+00 7.080E+07 00-60 0.000E+00 4.320E+07 1.270E+08 0.000E+00 0.OOOE+00 0.000E+00 2.390E+08 NI-63 2.960E+10 1.590E+09 1.010E+09 0.000E+00 0.000E+00 0.OOOE+00 1.070E+08 NI-65 1.660E+00 1.560E-01 9.110E-02 0.OOOE+00 0.000E+00 0.000E+00 1.910E+01 CU-64 0.000E+00 7.550E+04 4.560E+04 0.OOOE+00 1.820E+05 0.OOOE+00 3.540E+06 ZN-65 4.130E+09 1.100E+10 6.850E+09 0.OOOE+00 6.940E+09 0.000E+00 1.930E+09 ZN-69 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 2.140E-09 BR-82 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 BR-83 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 BR-84 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 BR-85 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 RB-86 0.OOOE+00 8.770E+09 5.390E+09 0.000E+00 0.000E+00 0.OOOE+00 5.640E+08 RB-88 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 RB-89 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 SR-89 6.620E+09 0.OOOE+00 1.890E+08 0.OOOE+00 0.OOOE+00 0.000E+00 2.560E+08 SR-90 1.120E+11 0.000E+00 2.830E+10 0.000E+00 0.OOOE+00 0.OOOE+00 1.510E+09 SR-91 1.41 OE+05 0.OOOE+00 5.330E+03 0.000E+00 0.OOOE+00 0.000E+00 3.120E+05 SR-92 2.190E+00 0.000E+00 8.760E-02 0.000E+00 0.OOOE+00 0.000E+00 4.140E+01 Y-90 3.220E+02 0.000E+00 8.610E+00 0.000E+00 0.000E+00 0.000E+00 9.150E+05 Y-91M 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 Y-91 3.910E+04 0.000E+00 1.040E+03 0.000E+00 0.000E+00 0.000E+00 5.210E+06 Y-92 2.460E-04 0.000E+00 7.030E-06 0.000E+00 0.000E+00 0.000E+00 7.100E+00 Y-93 1.060E+00 0.000E+00 2.900E-02 0.000E+00 0.000E+00 0,000E+00 1.570E+04

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 291 of 318 2 Gaseous Effluent Pathway Dose Factors GRASS-COW-MILK DOSE FACTORS CHILD (M 2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gltract ZR-95 3.840E+03 8.450E+02 7.520E+02 0.OOOE+00 1.210E+03 0.OOOE+00 8.81 OE+05 ZR-97 1.890E+00 2.720E-01 1.610E-01 0.OOOE+00 3.910E-01 0.OOOE+00 4.130E+04 NB-95 3.180E+05 1.240E+05 8.840E+04 0.OOOE+00 1.160E+05 0.OOOE+00 2.290E+08 NB-97 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.450E-06 MO-99 0.OOOE+00 8.290E+07 2.050E+07 0.OOOE+00 1.770E+08 0.OOOE+00 6.860E+07 TC-99M 1.290E+01 2.540E+01 4.200E+02 0.OOOE+00 3.680E+02 1,290E+01 1.440E+04 TC-101 0.OOOE+00 0.O00E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RU-103 4.290E+03 0.OOOE+00 1.650E+03 0.OOOE+00 1.080E+04 0.OOOE+00 1.11OE+05 RU-105 3.820E-03 O.OOOE+00 1.390E-03 O.OOOE+00 3.360E-02 O.OOOE+00 2.490E+00 RU-106 9.240E+04 O.OOOE+00 1.150E+04 O.OOOE+00 1.250E+05 O.OOOE+00 1.440E+06 RH-1 03M OOOOE+00 O.OOOE+00 O.OOOE+00 OOOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 RH-106 0,000E+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 0.OOOE+00 O.OOOE+00 O.OOOE+00 AG-110M 2.090E+08 1.410E+08 1.130E+08 O.OOOE+00 2.630E+08 0.OOOE+00 1.680E+10 SB-122 4.140E+06 4.320E+06 5.230E+07 6.870E+05 2.040E+06 8.890E+05 5.150E+08 SB-124 3.620E+09 4.700E+07 1.270E+09 7.990E+06 O.OOOE+00 2.010E+09 2.260E+10 SB-125 2.900E+09 2.240E+07 6.080E+08 2.690E+06 O.OOOE+00 1.620E+09 6.930E+09 TE-125M 7.380E+07 2.OOOE+07 9.840E+06 2.070E+07 O.OOOE+00 O.OOOE+00 7.120E+07 TE-127M 2.080E+08 5.600E+07 2.470E+07 4.970E+07 5.930E+08 O.OOOE+00 1.680E+08 TE-127 3.060E+03 8.250E+02 6.560E+02 2.120E+03 8.71OE+03 0.OOOE+00 1.200E+05 TE-129M 2.720E+08 7.610E+07 4.230E+07 8.780E+07 8.OOOE+08 0.OOOE+00 3.320E+08 TE-129 O.OOOE+00 0.OOOE+00 0.OOOE+00 O.OO0E+00 2.870E-09 0.OOOE+00 6.120E-08 TE-131M 1.600E+06 5.530E+05 5.890E+05 1.140E+06 5.350E+06 0.OOOE+00 2.240E+07 TE-131 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 TE-132 1.020E+07 4.520E+06 5.460E+06 6.580E+06 4.200E+07 0.OOOE+00 4.550E+07 1-130 1.750E+06 3.540E+06 1.820E+06 3.900E+08 5.290E+06 0.OOOE+00 1.660E+06 1-131 1.300E+09 1.310E+09 7.460E+08 4.340E+1i 2.150E+09 0.OOOE+00 1.170E+08 I-132 6.860E-01 1.260E+00 5.800E-01 5.850E+01 1.930E+00 0.OOOE+00 1.480E+00 1-133 1.760E+07 2.180E+07 8.230E+06 4.040E+09 3.630E+07 O.OOOE+00 8.770E+06 I-134 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 1-135 5.840E+04 1.050E+05 4.970E+04 9.300E+06 1.610E+05 0.OOOE+00 8.OOOE+04 CS-134 2.260E+10 3.710E+10 7.830E+09 0.OOOE+00 1.150E+10 4.130E+09 2.OOOE+08 CS-136 1.OOOE+09 2.760E+09 1.790E+09 0.OOOE+00 1.470E+09 2.190E+08 9.700E+07 CS-137 3.220E+i0 3.090E+10 4.550E+09 0.OOOE+00 1.010E+10 3,620E+09 1.930E+08 CS-138 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00

Rev.

00802 OFFSITE DOSE CALCULATION MANUAL Page 292 of 318

.nt Gaseous Effluent Pathway Dose Factors GRASS-COW-MILK DOSE FACTORS

ýCHILD (M2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract BA-139 2.140E-07 O.OOOE+00 6.190Eý09 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.230E-05 BA-140 1.170E+08 1.030E+05 6.840E+06 O.OOOE+00 3.340E+04 6.120E+04 5.940E+07 BA-141 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 BA-142 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 LA-140 1.930E+01 6.740E+00 2.270E+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.880E+05 LA-142 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 2.510E-06 CE-141 2.190E+64 1.090E+04 1.620E+03 O.OOOE+00 4.780E+03 0.000E+60 1.360E+07 CE-143 1.890E+02 1.020E+05 1.480E+01 O.OOOE+00 4.290E+01 O.OOOE+00 1.500E+06 CE-144 1.620E+06 5.090E+05 8.660E+04 O.OOOE+00 2.820E+05 O.OOOE+00 1.330E+08 PR-143 7.230E+02 2.170E+02 3.590E+01 O.OOOE+00 1.170E--02 O.OOOE+00 7.800E+05 PR-144 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+O0 O.OOOE+00 O.OOOE+00 O.OOOE+00 ND-147 4.450E+02 3.600E+02 2.790E+01 O.OOOE+00 1.980E+02 0.000E+0O 5.710E+05 EU-154 9.420E+04 8.470E+03 7.740E+03 O.OOOE+00 3.720E+04 O.OOOE+00 1.970E+06 EU-155 1.970E+04 1.420E+03 1.110E+03 O.OOOE+00 5.300E+03 O.OOOE+00 3.540E+06 W-187 2.910E+04 1.720E+04 7.730E+03 O.OOOE+OO O.OOOE+00 O.OOOE+00 2.420E+06 NP-239 1.720E+01 1.230E+00 8.680E-01 O.OOOE+00 3.570E+00 O.OOOE+00 9.140E+04

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 293 of 318 Attachment Gaseous Effluent Pathway Dose Factors GRASS-COW-MILK DOSE FACTORS INFANT (M 2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Thody Thyroid Kidney Lung Gitract H-3 0.OOOE+00 2.380E+03 2.380E+03 2.380E+03 2.380E+03 2.380E+03 2.380E+03 C-14 3.230E+06 6.890E+05 6.890E+05 6.890E+05 6.890E+05 6.890E+05 6.890E+05 NA-24 1.610E+07 1.610E+07 1.610E+07 1.610E+07 1.610E+07 1.610E+07 1.610E+07 P-32 1.600E+11 9.420E+09 6.210E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.170E+09 CR-51 0.OOOE+00 0.OOOE+00 1.610E+05 1.050E+05 2.300E+04 2.050E+05 4.710E+06 MN-54 0.OOOE+00 3.890E+07 8.830E+06 0.OOOE+00 8.630E+06 0.OOOE+00 1.430E+07 MN-56 0.OOOE+00 3.210E-02 5.530E-03 0.OOOE+00 2.760E-02 0.OOOE+00 2.910E+00 FE-55 1.350E+08 8.720E+07 2.330E+07 0.OOOE+00 0.OOOE+00 4.270E+07 1.11OE+07 FE-59 2.250E+08 3.930E+08 1.550E+08 0.OOOE+00 0.OOOE+00 1.160E+08 1.880E+08 CO-57 0.OOOE+00 8.950E+06 1.460E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.050E+07 CO-58 0.OOOE+00 2.430E+07 6.060E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.050E+07 CO-60 0.OOOE+00 8.81 OE+07 2.080E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.100E+08 NI-63 3.490E+10 2.160E+09 1.210E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.070E+08 NI-65 3.510E+00 3.970E-01 1.810E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.020E+01 CU-64 0.OOOE+00 1.880E+05 8.690E+04 0.OOOE+00 3.170E+05 0.OOOE+00 3.850E+06 ZN-65 5.550E+09 1.900E+10 8.780E+09 0.OOOE+00 9.230E+09 0.OOOE+00 1.610E+10 ZN-69 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.360E-09 BR-82 0.OOOE+00

.OOOE+00

.OOOE+00 0,000E+00

.OOOE+00 0.OOOE+00 0.OOOE+00 BR-83 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-84 0.000E+00 0.OOOE+00 O.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-86 0.OOOE+00 2.220E+10 1.100E+10 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.690E+08 RB-88 O.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 RB-89 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 SR-89 1.260E+10 0.OOOE+00 3.610E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.590E+08 SR-90 1.220E+11 0.OOOE+00 3.100E+10 O.OOOE+00 0.OOOE+00 0.OOOE+00 1.520E+09 SR-91 2.940E+05 O.OOOE+00 1.060E+04 O.OOOE+00 0.OOOE+00 0.OOOE+00 3.480E+05 SR-92 4.650E+00 0.OOOE+00 1.730E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.010E+01 Y-90 6.800E+02 0.OOOE+00 1.820E+01 0.000E+00 0.OOOE+00 0.OOOE+00 9.390E+05 Y-91M 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 Y-91 7.330E+04 0.OOOE+00 1.950E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.260E+06 Y-92 5.220E-04 0.OOOE+00 1.470E-05 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.970E+00 Y-93 2.250E+00 0.OOOE+00 6.130E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.780E+04

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 294 of 318 Gaseous Effluent Pathway Dose Factors GRASS-COW-MILK DOSE FACTORS INFANT (M2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Thody Thyroid Kidney Lung Giltract ZR-95 6.830E+03 1.660E+03 1.180E+03 0.000E+00 1.790E+03 0.000E+00 8.280E+05 ZR-97 3.990E+00 6.850E-01 3.130E-01 0.000E+00 6.910E-01 0.OOOE+00 4.370E+04 NB-95 5.930E+05 2.440E+05 1.41 OE+05 0.000E+00 1.750E+05 0.000E+00 2.060E+08 NB-97 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 3.700E-06 MO-99 0.OOOE+00 2.120E+08 4.130E+07 0.OOOE+00 3.170E+08 0.OOOE+00 6.980E+07 TC-99M 2.690E+01 5.550E+01 7.150E+02 0.OOOE+00 5.970E+02 2.900E+01 1.610E+04 TC-101 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 RU-103 8.690E+03 0.000E+00 2.910E+03 0.OOOE+00 1.810E+04 0.000E+00 1.060E+05 RU-105 8.060E-03 0.000E+00 2.710E-03 0.OOOE+00 5.920E-02 0.OOOE+00 3.210E+00 RU-1 06 1.900E+05 0.OOOE+00 2.380E+04 0.000E+00 2.250E+05 0.000E+00 1.440E+06 RH-103M 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 O.OOOE+00 RH-106 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 AG-110M 3.860E+08 2.820E+08 1.860E+08 0.000E+00 4.030E+08 0.000E+00 1.460E+10 SB-122 6.400E+05 6.670E+05 8.080E+06 1.060E+05 3.150E+05 1.370E+05 7.950E+07 SB-124 6.980E+09 1.030E+08 2.160E+09 1.850E+07 0.000E+00 4.370E+09 2.150E+10 SB-125 4.980E+09 4.820E+07 1.020E+09 6.240E+06 0.000E+00 3.130E+09 6.640E+09 TE-125M 1.510E+08 5.040E+07 2.040E+07 5.070E+07 0.000E+00 0.000E+00 7.180E+07 TE-127M 4.210E+08 1.400E+08 5.100E+07 1.220E+08 1.040E+09 0.000E+00 1.700E+08 TE-127 6.500E+03 2.180E+03 1.400E+03 5.290E+03 1.590E+04 0.000E+00 1.360E+05 TE-129M 5.590E+08 1.920E+08 8.620E+07 2.150E+08 1.400E+09 0.000E+00 3.340E+08 TE-129 2.080E-09 0.000E+00 0,0002+00 1.750E-09 5.180E-09 0.000E+00 1.660E-07 TE-131M 3.380E+06 1.360E+06 1.120E+06 2.760E+06 9.350E+06 0.000E+00 2.290E+07 TE-131 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 TE-132 2.100E+07 1.040E+07 9.720E+06 1.540E+07 6.510E+07 0.000E+00 3.850E+07 1-130 3.600E+06 7.920E+06 3.180E+06 8.880E+08 8.700E+06 0.000E+00 1.700E+06 1-131 2.720E+09 3.210E+09 1.410E+09 1.050E+12 3.750E+09 0.000E+00 1.150E+08 1-132 1.420E+00 2.890E+00 1.030E+00 1.350E+02 3.220E+00 0.000E+00 2.340E+00 1-133 3.720E+07 5.410E+07 1.580E+07 9.840E+09 6.360E+07 0.000E+00 9.160E+06 1-134 0.000E+00 0.000E+00 0.000E+00 1.010E-09 0.000E+00 0.000E+00 0.000E+00 1-135 1.210E+05 2.410E+05 8.800E+04 2.160E+07 2.690E+05 0.000E+00 8.740E+04 CS-134 3.650E+10 6.800E+10 6.870E+09 0.000E+00 1.750E+10 7.180E+09 1.850E+08 CS-136 1.960E+09 5.770E+09 2.150E+09 0.000E+00 2.300E+09 4.700E+08 8.760E+07 CS-137 5.150E+10 6.020E+10 4.270E+09 0.000E+00 1.620E+10 6.550E+09 1.880E+08 CS-138 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000E+00

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 295 of 318 Gaseous Effluent Pathway Dose Factors GRASS-COW-MILK DOSE FACTORS INFANT (M2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract BA-139 4.550E-07 O.OOOE+00 1.320E-08 O.OOOE+00 O.OOOE+00 O.OOOE+00 2.880E-05 BA-140 2.410E+08 2.410E+05 1.240E+07 O.OOOE+00 5.730E+04 1.480E+05 5.920E+07 BA-141 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 BA-142 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 LA-140 4.030E+01 1.590E+01 4.090E+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.870E+05 LA-142 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 0.000E+00 O.OOOE+00 5.21 OE-06 CE-141 4.330E+04 2.640E+04 3.11OE+03 O.OOOE+00 8.150E+03 O.OOOE+00 1.370E+07 CE-143 4.OOOE+02 2.650E+05 3.020E+01 O.OOOE+00 7.720E+01 O.OOOE+00 1.550E+06 CE-144 2.330E+06 9.520E+05 1.300E+05 O.OOOE+00 3.850E+05 O.OOOE+00 1.330E+08 PR-143 1.490E+03 5.590E+02 7.410E+01 O.OOOE+00 2.080E+02 O.OOOE+00 7.890E+05 PR-144 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 ND-147 8.820E+02 9.060E+02 5.550E+01 O.OOOE+00 3.490E+02 O.OOOE+00 5.740E+05 EU-154 1.080E+05 1.500E+04 9.010E+03 O.OOOE+00 4.070E+04 O.OOOE+00 1.880E+06 EU-155 2.210E+04 2.550E+03 1.320E+03 O.OOOE+00 5.710E+03 O.OOOE+00 3.410E+06 W-187 6.120E+04 4.260E+04 1.470E+04 O.OOOE+00 O.OOOE+00 O.OOOE+00 2.500E+06 NP-239 3.640E+01 3.250E+00 1.840E+00 O.OOOE+00 6.490E+00 O.OOOE+00 9.400E+04

OFFSlTE DOSE CALCULATION MANUAL Rev..

00802 Page 296 of 318 2 Gaseous Effluent Pathway Dose Factors GRASS-GOAT-MILK DOSE FACTORS ADULT (M 2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract H-3 C-14 NA-24 P-32 CR-51 MN-54 MN-56 FE-55 FE-59 CO-57 CO-58 CO-60 NI-63 NI-65 CU-64 ZN-65 ZN-69 BR-82 BR-83 BR-84 BR-85 RB-86 RB-88 RB-89 SR-89 SR-90 SR-91 SR-92 Y-90 Y-91 M Y-91 Y-92 Y-93 ZR-95 O.OOOE+00 3.630E+05 3.050E+05 2.050E+10 O.OOOE+00 O.OOOE+00 O.OOOE+00 3.260E+05 3.870E+05 O.OOOE+00 O.OOOE+00 O.OOOE+00 8.070E+08 4.440E-02 O.OOOE+00 1.650E+08 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 3.050E+09 9.830E+10 6.580E+04 1.030E+00 8.480E+00 O.OOOE+00 1.030E+03 6.510E-06 2.800E-02 1.140E+02 1.560E+03 7.260E+04 3.050E+05

  • 1.270E+09 O.OOOE+00
  • 1.010E+06 5.080E-04 2.250E+05 9.090E+05 1.540E+05 5.660E+05 1.970E+06 5.600E+07 6.770E-03 2.690E+03 5.240E+08 O.OOOE+OO O.OOOE+OO O.OOOE+OO O.OOOE+OO 0.OOOE+OO 3.11 OE+08 0.OOOE+00 O.OOOE+0O O.OOOE+OO O.OOOE+00 O.OOOE+OO 0.OOOE+O0 0.OOOE+OO O.OOOE+OO O.OOOE+00

.OOOE+00 O.OOOE+0O 3.640E+01 1.560E+03 7.260E+04 3.050E+05 7.930E+08 3.430E+03 1.920E+05 9.010E-05 5.260E+04 3.490E+05 2.550E+05 1.270E+06 4.340E+06 2.71 OE+07 2.630E 1.260E+03 2.370E+08 O.OOOE+00 3.900E+06 1.240E-02 O.OOOE+00 O.OOOE+00 1.450E+08 O.OOOE+00 0.OOOE+00 8.740E+07 2.410E+10 2.660E+03 4.440E-02 2.280E-01 O.OOOE+00 2.760E+61 1.900E-07 7.720E-04 2.470E+01 1.560E+03 7.260E+04 3.050E+05 O.OOOE+00 2.050E+03 O.OOOE+O0 O.OOOE+00 O.OOOE+00 O.OOOE+OO O.OOOE+00 O.OOOE+oo O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 0.00mE+00 O.OOOE+00 0.000E+00 0.600E+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.000E+00 O.OOOE+00 O.OOOE+00 1.560E+03 7.260E+04 3.050E+05 O.OOOE+OO 7.560E+02 3.OOOE+05 6.450E-04 0.000t+00 O.OOOE+OO O.OOOE-'-O O.OOOE+OO O.OOOE+OO O.OOOE+OO O.OOOE+OO 6.770E+03 3.500E+08 O.OOOE+OO O.OOOE+OO0 O.OOOE+OO O.OOOE+OO 0.00mE+00 O.OOOE+OO 0.000t+00 O.OOOE+OO O.OOOE+OO O.OOOE+OO O.OOOE+OO0 0.060E+00 O.OOOE+OO 0.0OOOE+OO 0.000L+00 O.OOOE+OO O.OOOE+OO 5.710E+01 1.560E+03 7.260E+04 3.050E+05 O.OOOE+00 4.560E+03 O.OOOE+00 O.OOOE+00 1.260E+05 2.540E+05 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+O0 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+O0 O.OOOE+00 O.OOOE+00 1.560E+03 7.260E+04 3.050E+05 2.310E+09 8.640E+05 3.090E+06 1.620E-02 1.290E+05 3.030E+06 3.900E+06 1.150E+07 3.700E+07 1.170E+07 1.460E-01 2.290E+05 3.300E+08 O.OOOE+00 4.470E+06 1.790E-02 O.OOOE+00 O.OOOE+00 6.140E+07 O.OOOE+00 O.OOOE+O0 4.890E+08 2.840E+09 3.130E+05 2.030E+01 8.990E+04 O.OOOE+00 5.680E+05 1.140E-01 8.870E+02 1.150E+05

OFFSITE DOSE CALCULATION MANUAL PRge 20 o2318 2 Gaseous Effluent Pathway Dose Factors GRASS-GOAT-MILK DOSE FACTORS ADULT (M 2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract ZR-97 5.11OE-02 1.030E-02 4.7102-03 0.000E+00 1.560E-02 0.OOOE+00 3.190E+03 NB-95 9.900E+03 5.510E+03 2.960E+03 0.000E+00 5.440E+03 0.OOOE+00 3.340E+07 NB-97 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00

.0.OOOE+00 MO-99 0.000E+00 3.030E+06 5.760E+05 0.OOOE+00 6.860E+06 0.000E+00 7.020E+06 TC-99M 3.900E-01 1.100E+00 1.400E+01 0.OOOE+00 1.670E+01 5.400E-01 6.520E+02 TC-101 0.000E+00 0.OOOE+00.

0.000E+00 0.OOOE+00 0.000E+00 0.000E+00

.0.000E+00 RU-103 1.220E+02 0.OOOE+00 5.270E+01 0.000E+00 4.670E+02 0.000E+00 1.430E+04 RU-105 1.030E-04 0.000E+00 4.060E-05 0.OOOE+00 1.330E-03 0.000E+00 6.290E-02 RU-106 2.450E+03 0.000E+00 3.100E+02 0.OOOE+00 4.730E+03 0.000E+00 1.580E+05 RH-103M 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 RH-106 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 AG-110M 6.990E+06 6.470E+06 3.840E+06 0.000E+00 1.270E+07 0.000E+00 2.640E+09 SB-122 7.210E+04 7.520E+04 9.11OE+05 1.200E+04 3.550E+04 1.550E+04 8.960E+06 SB-124 3.090E+06 5.840E+04 1.220E+06 7.490E+03 0.000E+00 2.410E+06 8.770E+07 SB-125 2.450E+06 2.740E+04 5.840E+05 2.490E+03 0.000E+00 1.890E+06 2.700E+07 TE-125M 1.950E+06 7.080E+05 2.620E+05 5.880E+05 7.950E+06 0.000E+00 7.810E+06 TE-127M 5.490E+06 1.960E+06 6.690E+05 1.400E+06 2.230E+07 0.OOOE+00 1.840E+07 TE-127 8.060E+01 2.890E+01 1.740E+01 5.970E+01 3.280E+02 0.OOOE+00 6.360E+03 TE-129M 7.250E+06 2.710E+06 1.150E+06 2.490E+06 3.030E+07 0.000E+00 3.650E+07 TE-129.

0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 TE-131M 4.330E+04 2.120E+04 1.770E+04 3.360E+04 2.150E+05 0.OOOE+00 2.100E+06 TE-131 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 TE-132 2.870E+05 1.860E+05 1.740E+05 2.050E+05 1.790E+06 0.OOOE+00 8.790E+06 1-130 5.110E+05 1.510E+06 5.950E+05 1.280E+08 2.350E+06 0.000E+00 1.300E+06 1-131 3.560E+08 5.090E+08 2.920E+08 1.6702+11 8.720E+08 0.OOOE+00 1.340E+08 1-132 1.960E-01 5.250E-01 1.840E-01 1.840E+01 8.360E-01 0.000E+00 9.860E-02 1-133 4.760E+06 8.280E+06 2.520E+06 1.220E+09 1.440E+07 0.OOOE+00 7.440E+06 1-134 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 1-135 1.670E+04 4.360E+04 1.610E+04 2.880E+06 6.990E+04 0.000E+00 4.920E+04 CS-134 1.700E+10 4.030E+10 3.300E+10 0.000E+00 1.310E+10 4.330E+09 7.060E+08 CS-136 7.840E+08 3.090E+09 2.230E+09 0.000E+00 1.720E+09 2.360E+08 3.520E+08 CS-137 2.210E+10 3.030E+10 1.980E+10 0.000E+00 1.030E+10 3.420E+09 5.860E+08 CS-138 0.000E+00 0.000E+00 0.000E+00 0.000E+00 0.000+E00 0.000E+00 0.000E+00

Rev.

00802 OFFSITE DOSE CALCULATION MANUAL PagRev 29f Pae298 of 318 Gaseous Effluent Pathway Dose Factors GRASS-GOAT-MILK DOSE FACTORS ADULT (M2 *mrem/yr per uCi/sec)

Thody Thyroid Kic Nuclide Bone Liver iney Lung Gitract BA-139 BA-140 BA-141 BA-142 LA-140 LA-142 CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 EU-154 EU-155 W-187 NP-239 5.640E-09 3.230E+06 O.OOOE+00 O.OOOE+00 5.380E-01 O.OOOE+00 5.810E+02 5.020E+00 4.290E+04 1.910E+01 O.OOOE+00 1.130E+01 2.840E+03 3.950E+02 7.870E+02 4.390E-01 O.OOOE+00 4.050E+03 O.OOOE+00 O.OOOE+00 2.710E-01 OOOOE+00 3.930E+02 3.71OE+03 1.790E+04 7.650E+00 O.OOOE+00 1.310E+01 3.490E+02 5.610E+01 6.580E+02 4.320E-02 O.OOOE+00 O.OOOE+00 2.11 OE+05 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.990E+04 O.OOOE+00 O.OOOE+00 O.OOOE+00 4.450E+01 O.OOOE+00 4.11 OE-01 O.OOOE+00 2.300E+03 O.OOOE+00 9.450E-01 O.OOOE+00 O.OOOE+00 O.OOOE+00 7.820E-01 O.OOOE+00 2.480E+02 O.OOOE+00 3.620E+01 O.OOOE+00 2.300E+02 O.OOOE+00 2.380E-02 O.OOOE+00 O.OOOE+00 1.380E+03 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.820E+02 1.630E+00 1.060E+04 4.410E+00 O.OOOE+O0 7.640E+00 1.670E+03 2.590E+02 0,000E+00 1.350E-01 O.OOOE+00 1.OOOE-08 2.320E+03 6.650E+06 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 1.990E+04 O.OOOE+00 3.640E-09 O.OOOE+00 1.500E+06 O.OOOE+00 1.390E+05 O.OOOE+00 1.450E+07 O.OOOE+00 8,350E+04 O.OOOE+00 O.OOOE+00 O.OOOE+00 6.270E+04 O.OOOE+00 2.530E+05 O.OOOE+00 4.41 OE+04 O.OOOE+00 2.160E+05 O.OOOE+00 8.860E+03

Rev.

00802 OFFSITE DOSE CALCULATION MANUAL Page 299 of 318 knt Gaseous Effluent Pathway Dose Factors GRASS-GOAT-MILK DOSE FACTORS TEEN (M2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract H-3 0.OOOE+00 2.030E+03 2.030E+03 2.030E+03 2.030E+03 2.030E+03 2.030E+03 C-14 6.700E+05

!.340E+05 1.340E+05 1.340E+05 1.340E+05 1.340E+05 1.340E+05 NA-24 5.330E+05 5.330E+05 5.330E+05 5.330E+05 5.330E+05 5.330E+05 5.330E+05 P-32 3.780E+10 2.340E+09 1.470E+09 0.OOOE+00 0.OOOE+00 o.oooE+o0 3.180E+09 CR-51 0.OOOE+00 0.OOOE+00 6.OOOE+03 3.330E+03 1.310E+03 8.560E+03 1.010E+06 MN-54 0.OOOE+00 1.680E+06 3.330E+05 0.OOOE+00 5.010E+05 0.OOOE+00 3.440E+06 MN-56 0.OOOE+00 9.010E-04 1.600E-04 0.OOOE+00 1.140E-03 0.OOOE+00 5.930E-02 FE-55 5.790E+05 4.100E+05 9.570E+04 0.OOOE+00 0.OOOE+00 2.600E+05 1.780E+05 FE-59 6.750E+05 1.580E+06 6.090E+05 0.OOOE+00 0.OOOE+00 4.970E+05 3.730E+06 CO-57 0.OOOE+00 2.690E+05 4.520E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.030E+06 CO-58 0.OOOE+00 9.540E+05 2.200E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.310E+07 CO-60 0.OOOE+00 3.340E+06 7.510E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.350E+07 NI-63 1.420E+09 1.OOOE+08 4.810E+07 0.OOOE+00 O.OOE+00 0.OOOE+00 1.590E+07 NI-65 8.130E-02 1.040E-02 4.730E-03 0.OOE+00 0.OOOE+00 0,000E+00 5.640E-01 CU-64 0.OOOE+00 4.790E+/-03 2.250E+03 0.OOOE+00 1.210E+04 0.OOOE+00 3.710E+05 ZN-65 2.530E+08 8.780E+08 4.090E+08 0.OOOE+00 5.620E+08 0.OOOE+00 3.720E+08 ZN-69 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-82 0.OOOE+00 0.OOOE+00 6.670E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-83 0.OOOE+00 0.OOOE+00 2.290E-02 O.OOOE+00 0.OOOE+00' 0.OOOE+00 0.OOOE+00 BR-84 0.OOOE+00 O.OOOE+00 O.OOOE+00 0.OOOE+Q0 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-85 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-86 0.OOOE+00 5.670E+08 2.670E+08 0.OOOE+00 0.OOOE+00 6.000E+00 8.400E+07 RB-88 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-89 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+/-00 0.OOOE+00 0.OOOE+O0 0.OOOE+00 SR-89 5.620E+09 0.OOOE+00 1.160E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.690E+08 SR-90 1.390E+1 1 0.OOOE+00 3.430E+1 1 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.900E+09 SR-91 1.210E+05 0.OOOE+00 4.810E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 5.480E+05 SR-92 1.880E+00 0.OOOE+00 8.010E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.790E+01 Y-90 1.560E+01 0.OOOE+00 4.200E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.290Et05 Y-91M 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 Y-91 1.900E+03 0.OOOE+00 5.090E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.780E+05 Y-92 1.200E-05 0.OOOE+00 3.480E-07 0.OOOE+00 0.OOOE+00 0000E+00 3.300E-01 Y-93 Y-3 5.160E-02 0.OOOE+00 1.410E-03 O.OOOE+00 0.OOOE+00 0.OOOE+00 1.580E+03

FSIT DRev.

00802 O FFTE DOSE CALCULATION MANUAL Page 300 of 318 2

Gaseous Effluent Pathway Dose Factors GRASS-GOAT-MILK DOSE FACTORS TEEN (M2 *mrem/yr per uCi/sec)

Thody Thyroid Nuclide Bone Liver Kidney Lung Gitract ZR-95 ZR-97 NB-95 NB-97 MO-99 TC-99M TC-101 RU-103 RU-105 RU-106 RH-103M RH-106 AG-110M SB-122 SB-124 SB-125 TE-125M TE-127M TE-127 TE-1 29M TE-129 TE-131M TE-131 TE-132 1-130 1-131 1-132 1-133 1-134 1-135 CS-134 CS-136 CS-1 37 CS-138 1.990E+02 9.300E-02 1.690E+04 0.OOOE+00 0.000E+00 6.770E-01 0.OOOE+00 2.180E+02 1.880E-04 4.500E+03 0.OOOE+00 0.OOOE+00 1.160E+07 9.310E+04 5.51 OE+06 4.380E+06 3.600E+06 1.010E+07 1.490E+02 1.330E+07 0.OOOE+00 7.890E+04 0.000E+00 5.1 30E+05 8.990E+05 6.450E+08 3.480E-01 8.690E+06 0.OOOE+00 2.960E+04 2.940E+10 1.330E+09 4.020E+10 0.OOOE+00 6.260E+01 I1.840E-02 9.370E+03 0.000E+00 5.470E+06 I1.890E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.090E+07 9.71 OE+04 I1.020E+05 4.790E+04 1.300E+06 3.590E+06 5.290E+01 4.920E+06 0.OOOE+00 3.780E+04 0.OOOE+00 3.250E+05 2.600E+06 9.030E+08 9.1 10E-01 1.470E+07 0.OOOE+00 7.620E+04 6.930E+1 0 5.250E+09 5.340E+10 0.OOOE+00 4.310E+01 0.OOOE+00 9.200E+01 8.480E-03 0.OOOE+00 2.790E-02 5.160E+03 0.OOOE+00 9.080E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.040E+06 0.OOOE+00 1.250E+07 2.450E+01 0.OOOE+00 2.810E+01 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.310E+01 0.OOOE+00 7.670E+02 7.290E-05 0.OOOE+00 2.370E-03 5.670E+02 0.OOOE+00 8.680E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 6.650E+06 0.000E+00 2.090E+07 1.180E+06 1.540E+04 4.580E+04 2.150E+06 1.250E+04 0.OOOE+00 1.030E+06 4.190E+03 0.000E+00 4.820E+05 1.010E+06 0.OOOE+00 1.200E+06 2.41 OE+06 4.100E+07 3.210E+01 1.030E+02 6.050E+02 2.100E+06 4.280E+06 5.550E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.150E+04 5.690E+04 3.940E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.060E+05 3.430E+05 3.120E+06 1.040E+06 2.120E+08 4.010E+06 4.850E+08 2.640E+1 1 1.560E+09 3.270E-01 3.070E+01 1.430E+00 4.500E+06 2.060E+09 2.590E+07 O.OOOE+00 O.OOOE+00 O.000E+00 2.820E+04 4.900E+06 1.200E+05 3.210E+10 O.OOOE+00 2.200E+10 3.530E+09 O.OOOE+00 2.860E+09 1.860E+10 O.OOOE+00 1.820E+10 O.OOOE+00 O.OOOE+00 O.OOOE+00 0.OOOE+00 1.450E+05 0.OOOE+00 4.980E+03 0.OOOE+00 4.010E+07 0.OOOE+00 7.61 OE-09 0.OOOE+00 9.800E+06 1.050E+00 1.240E+03 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.820E+04 0.OOOE+00 1.520E-01 0.OOOE+00 2.160E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.070E+09 2.OOOE+04 1.160E+07 4.810E+06 1.11OE+08 3.850E+06 3.410E+07 0.OOOE+00 1.060E+07 0.OOOE+00 2.520E+07 O.OOOE+00 1.150E+04 O.OOOE+00 4.980E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.030E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.030E+07 0.000E+00 2.000E+06 0.OOOE+00 1.790E+08 0.OOOE+00 3.970E-01 0.OOOE+00 1.120E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 8.440E+04 8.41 OE+09 8.620E+08 4.51 OE+08 4.230E+08 7.060E+09 7.600E+08 0.OOOE+00 0.OOOE+00

OFFSlTE DOSE CALCULATION MANUAL Rev.

00802 Page 301 of 318 Gaseous Effluent Pathway Dose Factors GRASS-GOAT-MILK DOSE FACTORS TEEN (M2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract BA-1 39 1.040E-08 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 9.31 OE-08 BA-140 5.830E+06 7.140E+03 3.750E+05 0.OOOE+00 2.420E+03 4.800E+03 8.980E+06 BA-141 0.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.000E+00 0.000E+00 0.OOOE+00 BA-142 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 LA-140 9.760E-01 4.750E-01 1.260E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.730E+04 LA-142 1.980E-12 8.780E-13 2.190E-13 0.000E+00 0.OOOE+00 0.000E+00 2.670E-08 CE-141 1.060E+03 7.11OE+02 8.170E+01 0.OOOE+00 3.350E+02 0.OOOE+00 2.030E+06 CE-143 9.230E+00 6.720E+03 7.500E-01 0.OOOE+00 3.010E+00 0.000E+00 2.020E+05 CE-144 7.900E+04 3.270E+04 4.240E+03 0.OOOE+00 1.950E+04 0.OOOE+00 1.990E+07 PR-143 3.500E+01 1.400E+01 1.740E+00 0.OOOE+00 8.130E+00 0.OOOE+00 1.150E+05 PR-144 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 ND-147 2.180E+01 2.370E+01 1.420E+00 0.OOOE+00 1.390E+01 0.OOOE+00 8.530E+04 EU-154 4.700E+03 6.070E+02 4.280E+02 0.OOOE+00 2.720E+03 0.OOOE+00 3.21 OE+05 EU-155 1.030E+03 9.970E+01 6.170E+01 0.OOOE+00 3.900E+02 0.000E+00 5.71OE+05 W-187 1.440E+03 1.170E+03 4.11OE+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.180E+05 NP-239 8.390E-01 7.910E-02 4.390E-02 0.OOOE+00 2.480E-01 0.OOOE+00 1.270E+04

Rev.

00802 OFFSlTE DOSE CALCULATION MANUAL Page 302 of 318 Gaseous Effluent Pathway Dose Factors GRASS-GOAT-MILK DOSE FACTORS CHILD (M2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Thody Thyroid Kidney Lung Gitract H-3 0.OOOE+00 3.200E+03 3.200E+03 3.200E+03 3.200E+03 3.200E+03 3.200E+03 C-14 1.650E+06 3.290E+05 3.290E+05 3.290E+05 3.290E+05 3.290E+05 3.290E+05 NA-24 1.11OE+06 1.11OE+06 1.110E+06 1.110E+06 1.110E+06 1.110E+06 1.110E+06 P-32 9.330E+10 4.370E+09 3.600E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.580E+09 CR-51 O.OOOE+00 0.OOOE+00 1.220E+04 6.790E+03 1.860E+03 1.240E+04 6.490E+05 MN-54 0.000E+00 2.510E+06 6.690E+05 O.OOOE+00 7.050E+05 O.OOOE+00 2.11OE+06 MN-56 O.OOOE+00 1.570E-03 3.550E-04 O.OOOE+00 1.900E-03 0.OOOE+00 2.280E-01 FE-55 1.450E+06 7.700E+05 2.390E+05 O.OOOE+00 0.OOOE+00 4.360E+05 1.430E+05 FE-59 1.570E+06 2.530E+06 1.260E+06 0.OOOE+00 0.OOOE+00 7.350E+05 2.640E+06 CO-57 0.OOOE+00 4.600E+05 9.320E+05 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.770E+06 CO-58 0.OOOE+00 1.460E+06 4.460E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 8.500E+06 CO-60 0.OOOE+00 5.180E+06 1.530E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.870E+07 NI-63 3.560E+09 1.900E+08 1.210E+08 0.OOOE+00 O.OOOE+00 0.OOOE+00 1.280E+07 NI-65 1.990E-01 1.870E-02 1.090E-02 0.OOOE+00 O.OOOE+00 0.OOOE+00 2.290E+00 CU-64 O.OOOE+00 8.410E+03 5.080E+03 0.OOOE+00 2.030E+04 O.OOOE+00 3.950E+05 ZN-65 4.960E+08 1.320E+09 8.220E+08 0.OOOE+00 8.330E+08 0.OOOE+00 2.320E+08 ZN-69 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 BR-82 0.OOOE+00 0.OOOE+00 1.390E+07 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 BR-83 0.OOOE+00 0.OOOE+00 5.620E-02 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-84 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 BR-85 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 RB-86 0.OOOE+00 1.050E+09 6.470E+08 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.770E+07 RB-88 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RB-89 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 SR-89 1.390E+10 0.OOOE+00 3.970E+08 0.OOOE+00 0.000E+00 0.000E+00 5.380E+08 SR-90 2.350E+11 0.OOOE+00 5.950E+10 O.OOOE+00 0.OOOE+00 0.OOOE+00 3.190E+09 SR-91 2.970E+05 0.OOOE+00 1.120E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.550E+05 SR-92 4.590E+10 0.OOOE+00 1.840E-01 0.OOOE+00 0.OOOE+00 0.OOOE+00 8.690E+01 Y-90 3.860E+01 0.OOOE+00 1.030E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.100E+05 Y-91M 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 Y-91 4.690E+03 0.OOOE+00 1.250E+02 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.250E+05 Y-92 2.950E-05 0.OOOE+00 8.440E-07 0.OOOE+00 0.OOOE+00 0.000E+00 8.520E-01 Y-93 1.270E-01 0.OOOE+00 3.480E-03 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.890E+03 ZR-95 4.610E+02 1.010E+02 9.030E+01 0.OOOE+00 1.450E+02 0.OOOE+00 1.060E+05

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 DOS CPage 303 of 318 2 Gaseous Effluent Pathway Dose Factors GRASS-GOAT-MILK DOSE FACTORS CHILD (M2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract ZR-97 2.260E-01 3.270E-02 1.930E-02 0.OOOE+00 4.690E-02 0.OOOE+00 4.950E+03 NB-95 3.810E+04 1.480E+04 1.060E+04 0.OOOE+00 1.390E+04 0.OOOE+00 2.750E+07 NB-97 0.OOOE+/-+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.740E-07 MO-99 0.OOOE+00 9.950E+06 2.460E+06 0.OOOE+00 2.120E+07 0.OOOE+00 8.230E+06 TC-99M 1.550E+00 3.040E+00 5.040E+01 0.OOOE+00 4.420E+01 1.550E+00 1.730E+03 TC-101 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RU-103 5.150E+02 0,000E+00 1.980E+02 0.OOOE+00 1.300E+03 0,OOOE+00 1.330E+04 RU-105 4.590E-04 O.OOOE+00 1.660E-04 0.OOOE+00 4.030E-03 0.OOOE+00 2.990E-01 RU-106 1.110E+04 0.OOOE+00 1.380E+03 0.OOOE+00 1.500E+04 0.OOOE+00 1.720E+05 RH-103M 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 RH-106 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.OOOE+00 AG-110M 2.510E+07 1.690E+07 1.350E+07 0.OOOE+00 3.150E+07 0.OOOE+00 2.010E+09 SB-122 7.680E+04 8.010E+04 9.700E+05 1.270E+04 3.780E+04 1.650E+04 9.540E+06 SB-124 1.300E+07 1.690E+05 4.570E+06 2.880E+04 0.OOOE+00 7.240E+06 8.150E+07 SB-125 1.040E+07 8.050E+04 2.190E+06 9.670E+03 0.OOOE+00 5.820E+06 2.490E+07 TE-125M 8.850E+06 2.400E+06 1.180E+06 2.480E+06 0.OOOE+00 0.OOOE+00 8.540E+06 TE-127M 2.500E+07 6.720E4-06 2.960E+06 5.970E+06 7.120E+07 0.OOOE+00 2.020E+07 TE-127 3.670E&02 9.910E+01 7.880E+01 2.540E+02 1.050E+03 0.OOOE+00 1.440E+04

  • TE-129M 3.270E+07 9.130E+06 5.080E+06 1.050E+07 9.600E+07 0.OOOE+00 3.990E+07 TE-129 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 7.340E-09 TE-1 31 M 1.920E+05 6.640E+04 7.070E+04 1.370E+05 6.430E+05 0.OOOE+00 2.690E+06 TE-131 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 TE-132 1.230E+06 5.420E+05 6.550E+05 7.900E+05 5.040E+06 0.OOOE+00 5.460E+06 1-130 2.100E+06 4.250E+06 2.190E+06 4.680E+08 6.350E+06 0.OOOE+00 1.990E+06 1-131 1.570E+09 1.570E+09 8.950E+08 5.210E+11 2.580E+09 0.OOOE+00 1.400E+08 1-132 8.230E-01 1.510E+00 6.960E-01 7.020E+01 2.320E+00 0.OOOE+00 1.780E+00 1-133 2.11OE+07 2.610E+07 9.880E+06 4.850E+09 4.350E+07 0.000E+00 1.050E+07 1-134 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 1-135 7.OOOE+04 1.260E+05 5.960E+04 1.120E+07 1.930E+05 0.OOOE+00 9.600E+04 CS-134 6.790E+10 1.110E+11 2.350E+10 0.OOOE+00 3.450E+10 1.240E+10 6.010E+08 CS-136 3.010E+09 8.280E+09 5.360E+09 O.OOOE+00 4.410E+09 6.580E+08 2.910E+08 CS-137 9.670E+10 9.260E+10 1.370E+10 0.OOOE+00 3.020E+10 1.090E+10 5.800E+08 CS-1 38 0.000E+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 304 of 318 iment Gaseous Effluent Pathway Dose Factors Nuclide BA-1 39 BA-140 BA-141 BA-142 LA-140 LA-142 CE-141 CE-143 CE-144 PR-143 PR-144 ND-147 EU-154 EU-155 W-187 NP-239 Bone 2.560E-08 1.41 0E+07 0.000E+00 0.000E+00 2.31 0E+00 4.770E-12 2.620E+03 2.270E+01 1.950E+05 8.670E+01 O.000E+00 5.340E+01 1.130E+04 2.360E+03 3.490E+03 2.060E+00 Livel 0.000D~

1.230D~

Q.OOQE 0.000&~

8.090E-1.520E-i.3i0E&

i1.230D~

6.1 OOE+

2.600E+

0.000&~

4.320&~

i1.020E+

i1.700E+

2.070E+

1.480E-GRASS-GOAT-MILK DOSE FACT(

CHILD (M2 *mrem/yr per uCi/sec) r Tbody Thyroid

+00 0.OOOE+00 0.OOOE+00

+04 8.21OE+05 O.OOOE+00

-00 0.000E+00 0.OOOE+00

+00 0.OOOE+00 0.OOOE+00 01 2.730E-01 0.000E+00

-12 4.770E-13 0.OOOE+00

+03 1.940E+02 0.000E+00

+04 1.780E+00 0.000E+00

+04 1.040E+04 0.OOOE+00

+01 4.300E+00 0.000E+00

+00 0.000E+00 0.000E+00

+01 3.350E+00 0.OOOE+00

+03 9.290E+02 0.000E+00

-02 1.330E+02 0.OOOE+00

-03 9.270E+02 O.O00E+00 01 1.040E-01 0.000E+00 Kidney Lung Gitract 0.000E+00 0.000E+00 1.480E-06 4.010E+03 7.340E+03 7.120E+06 0.000E+00 0.000E+00 0.000E+00 O.000E+00 O.O00E+00 O.000E+00 O.000E+00 O.OOOE+00 2.260E+04 0.OOOE+00 0.000E+00 3.020E-07 5.730E+02 0.000E+00 1.630E+06 5.150E+00 0.OOOE+00 1.800E+05 3.380E+04 0.000E+00 1.590E+07 1.410E+01 0.OOOE+00 9.350E+04 0.000E+00 0.OOOE+00 0.000E+00 2.370E+01 0.000E+00 6.850E+04 4.470E+03 0.OOOE+00 2.360E+05 6.630E+02 0.OOOE+00 4.250E+05 0.OOOE+00 0.OOOE+00 2.900E+05 4.280E-01 0.000E+00 1.100E+04

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 DPage 305 of 318 2 Gaseous Effluent Pathway Dose Factors GRASS-GOAT-MILK DOSE FACTORS INFANT (i 2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract H-3 C-14 NA-24 P-32 CR-51 MN-54 MN-56 FE-55 FE-59 CO-57 CO-58 CO-60 NI-63 NI-65 CU-64 ZN-65 ZN-69 BR-82 BR-83 BR-84 BR-85 RB-86 RB-88 RB-89 SR-89 SR-90 SR-91 SR-92 Y-90 Y-91 M Y-91 Y-92 Y-93 ZR-95 0.OOOE+00 3.230E+06 1.930E+06 1.920E+1 1 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.760E+06 2.920E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.190E+09 4.210GE-01 0.OOOE+00 6.660E+08 0.OOOE+O0 0.000E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+0O 2.640E+1 0 2.550E+1 1 6.1 80E+05 9.760E+00 8.160E+01 0.OOOE+00 8.800E+03 6.270E-05 2.700E-01 8.190E+02 4.860E+03 6.890E+05 1.930E+06 1.130E+10 0.OOOE+00 4.670E+06 3.850E-03

1..130E+06 5.11 OE+06 1.070E+06 2.910E+06.

1.060E+07 2.590E+08 4.770E-02 2.090E+04 2.280E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.670E+09 0.OOOE+00 0.00O11+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+ý00 0.OOOEt00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.000E+02 4.860E+03 6.890E+05 1.930E+06 7.450E+09 1.940E+04 1.060E+06 6.630E-04 3.030E+05 2.010E+06 1.750E+06 7.270E+06 2.500E+07 1.450E+08 2.170E-02 9.680E+03 1.050E+09 0.OOOE+00 2.330E+07 1.190E-01 0.OOOE+00 0.OOOE+00 1.320E+09 0.OOOE+00 0.OOOE+00 7.580E+08 6.500E+10 2.240E+04 3.620E-01 2.190E+00 0.OOOE+00 2.340E+02 1.760E-06 7.350E-03 1.420E+02 4.860E+03 6.890E+05 1.930E+06 0.OOOE+00 1.260E+04 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.060E+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 o.6OOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 4.860E+03 4.860E+03 6.890E+05 6.890E+05 1.930E+06 1.930E+06.

0.OOOE+00 0.OOOE+00 2.760E+03 2.460E+04 1.040E+06 0.OOOE+00 3.31 OE-03 0.OOOE+00 0.OOOE+00 5.540E+05 0.OOOE+00 1.510E+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+O0 0.OOOE+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 3.540E+04 0.OOOE+00 1.110E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+06 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00

  • .OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.150E+02 0.OOOE+00 4.860E+03 6.890E+05 1.930E+06 2.600E+09 5.650E+05 1.720E+06 3.490E-01 1.440E+05 2.440E+06 3.660E+06 7.260E+06 2.520E+07 1.290E+07 3.630E+00 4.290E+05 1.930E+09 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 6.830E+07 0.OOOE+00 0.OOOE+00 5.430E+08 3.1 90E+09 7.310OE+05 1.050E+02 1.130E+05 0.OOOE+00 6.31 OE+05 1.200E+10 2.1 30E+03 9.940E+00

Rev.

00802 OFFSITE DOSE CALCULATION MANUAL Re 802 Page 306 of 318 2 Gaseous Effluent Pathway Dose Factors GRASS-GOAT-MILK DOSE FACTORS INFANT (M 2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract ZR-97 4.790E-01 8.220E-02 3.760E-02 0.OOOE+00 8.290E-02 0.600E+00 5.240E+03 NB-95 7.120E+04 2.930E+04 1.690E+04 0.OOOE+00 2.100E+04 0.OOOE+00 2.470E+07 NB-97 6.590E-12 1.410E-12 5.070E-13 0.OOOE+00 1.100E-12 0.OOOE+00 4.440E-07 MO-99 0.OOOE+00 2.540E+07 4.960E+06 0.OOOE+00 3.800E+07 0.OOOE+00 8.830E+06 TC-99M 3.230E+00 6.660E+00 8.570E+01 0.OOOE+00 7.160E+01 3.480E+00 1.930E+03 TC-101 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 RU-103 1.040E+03 0.OOOE+00 3.490E+02 0.OOOE+00 2.170E+03 0.000E+60 1.270E+04 RU-105 9.670E-04 0.OOOE+00 3.260E-04 0.OOOE+00 7.11OE-03 0.OOOE+00 3.850E-01 RU-106 2.280E+04 0.OOOE+00 2.850E+03 0.OOOE+00 2.700E+04 0.OOOE+00 1.730E+05 RH-103M 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0,000E+00 RH-106 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00

.0.OOOE+00 0.OOOE+00 0.OOOE+00 AG-110M 4.630E+07 3,380E+07 2.240E+07 0.OOOE+00 4.840E+07 0.OOOE+00 1.750E+09 SB-122 7.680E+04 8.010E+04 9.700E+05 1.270E+04 3.780E+04 1.650E+04 9.540E+06 SB-124 2.510E+07 3.700E+05 7.790E+06 6.670E+04 0.OOOE+00 1.570E+07 7.750E+07 SB-125 1.790E+07 1.740E+05 3.690E+06 2.250E+04 0.OOOE+00 1.130E+07 2.390E+07 TE-125M 1.810E+07 6.050E+06 2.450E+06 6.090E+06 0.OOOE+00 0.OOOE+00 8.620E+06 TE-127M 5,050E+07 1.680E+07 6.120E+06 1.460E+07 1.240E+08 0.OOOE+00 2.040E+07 TE-127 7.800E+02 2.610E+02 1.680E+02 6.350E+02 1.900E+03 0.OOOE+00 1.640E+04 TE-129M 6.710E+07 2.300E+07 1.030E+07 2.580E+07 1.680E+08 0.OOOE+60 4.010E+07 TE-129 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 2.OOOE-08 TE-131M 4.050E+05 1.630E+05 1.350E+05 3.310E+00 1.120E+06 0.OOOE+00 2.750E+06 TE-131 O.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 TE-132 2.520E+06 1.250E+06 1.170E+06 1.840E+06 7.820E+06 0.OOOE+00 4.620E+06 1-130 4.320E+06 9.510E+06 3.820E+06 1.070E+09 1.040E+07 0.OOOE+00 2.040E+06 1-131 3.270E+09 3.850E+09 1.690E+09 1.270E+12 4.500E+09 0.OOOE+00 1.370E'+08 1-132 1.710E+00 3.470E+00 1.230E+00 1.630E+02 3.870E+00 0.OOOE+00 2.810E+00 1-133 4.460E+07 6.490E+07 1.900E+07 1.180E+10 7.630E+07 0.OOOE+00 1.100E+07 1-134 0.OOOE+00 0.OOOE+00 0.OOOE+00 1.210E-09 0.OOOE+00 0.OOOE+00 0.OOOE+00 1-135 1.460E+05 2.900E+05 1.060E+05 2.600E+07 3.230E+05 0.OOOE+00 1.050E+05 CS-134 1.090E+11 2.040E+11 2.060E+10 0.OOOE+00 5.250E+10 2.150E+10 5.540E+08 CS-136 5.880E+09 1.730E+10 6.460E+09 0.OOOE+00 6.900E+09 1.410E+09 2.630E+08 CS-137 1.540E+11 1.810E+11 1.280E+10 0.000E+00 4.850E+10 1.960E+10 5.650E+08 CS-1 38 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00

oFFSITE DOSE CALCULATION MANUAL.

Rev.

00802 Page 307 of 318 Attachmel Gaseous Effluent Pathway Dose Factors GRASS-GOAT-MILK DOSE FACTORS INFANT (i

2 *mrem/yr per uCi/sec)

Nuclide Bone Liver Tbody Thyroid Kidney Lung Gitract BA-139 5.450E-08 0.000E+00 1.580E-09 O.OOOE+00 O.OOOE+00 O.OOOE+00 3.450E-06 BA-140 2.890E+07 2.890E+04 1.490E+06 O.OOOE+00 6.870E+03 1.780E+04 7.11OE+06 BA-141 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 0.OOOE+00 O.OOOE+00 O.OOOE+00 BA-142 O.OOOE+00 O.OOOE+00 O.OOOE+00 0.000E+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 LA-140 4.840E+00 1.910E+00 4.900E-01 O.OOOE+00 O.OOOE+00 O.OOOE+00 2.240E+04 LA-142 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 CE-141 5.200E+03 3.170E+03 3.730E+02 O.OOOE+00 9.780E+02 O.OOOE+00 1.640E+06 CE-143 4.800E+01 3.180E+04 3.630E+00 O.OOOE+00 9.270E+00 OOOOE+00 1.860E+05 CE-144 2.790E+05 1.140E+05 1.560E+04 O.OOOE+00 4.620E+04 O.OOOE+00 1.600E+07 PR-143 1.790E+02 6.710E+01 8.890E+00 O.OOOE+00 2.490E+01 O.OOOE+00 9.470E+04 PR-144 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 ND-147 1.060E+02 1.090E+02 6.660E+00 O.OOOE+00 4.190E+01 O.OOOE+00 6.890E+04 EU-154 14300E+04 1.800E+03 1.080E+03 O.OOOE+00 4.890E+03 O.OOOE+00 2.250E+05 EU-155 2.650E+03 3.060E+02 1.580E+02 O.000E+00 6.850E+02 O.000E+00 4.100E+05 W-187 7.350E+03 5.110E+03 1.770E+03 O.OOOE+00 O.OOOE+00 O.OOOE+00 3.OOOE+05 NP-239 4.360E+00 3.900E-01 2.210E-01 O.OOOE+00 7.780E-01 O.OOOE+00 1.130E+04

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 308 of 318 3 Environmental Monitoring Sites for REMP SAMPLE SITE DR1 DR2 DR3 DR4 NWý Wý SECTOR E

W VNW

)ISTANCE' km mi DESCRIPTION DR5 DR6, A4 DR7, Al, Ib4, Ib5, Ib6 DR8, A2 DR9, A3 DR10 DR11 DR12 DR1 3 DR14 DR1 5 DR16 DR1 7 DR1 8 DR1 9 DR20 DR21, A5, Ib7, Ib8, Ib9 DR22 DR23 Wal Wa2, lal, la2 Wbl Ibl, Ib2, Ib3, la4, la5 la3 1a6 WSW SW SSW S

SSE SE NW WNW W

WSW SW SSW S

SSE 0.6 0.4 Onsite, Along Cliffs 2.7 1.7 Rt. 765, Auto Dump 2.3 1.4 Rt. 765, Giovanni's Tavern (Knotty Pine) 2.0 1.2 Rt. 765, Across from White Sand Drive 2.4 1.5 Rt. 765 at Johns Creek 2.9 1.8 Rt. 765 at Lusby, Frank's Garage 0.7 0.5 Onsite, before entrance to Camp Conoy 2.5 1.5 Camp Conoy Road at Emergency Siren 2.6 1.6 Bay Breeze Road 6.4 4.0 Calvert Beach Rd & Decatur St 6.6 4.1 Dirt Road off Mackall Rd & Parran Rd 6.7 4.2 Bowen Rd & Mackall Rd 6.1 3.8 Mackall Rd near Waliville 6.4 4.0 Rodney Point 6.2 3.9 Mill Bridge Rd & Turner Rd 6.5 4.1 Across from Appeal School 5.9 3.7 Cove Point Rd & Little Cove Point Rd

.7.1 4.5 Cove Point 4.4 2.8 Long Beach 0.4 0.3 Onsite, near shore 19.3 12.1 Emergency Operations Facility 12.5 7.8 Solomons Island 12.4 7.7 Taylors Island, Anderson's Property 0.2 0.1 Intake Area 0.3 0.2 Discharge Area 0.6 0.4 Shoreline at Barge Road 2.6 1.6 Garden Plot off Bay Breeze Rd ed bv Plant Patuxent River SE NW NNW WNW S

ENE NNE N

ESE SSE (Area not influenc Discharge)

E NNW 0

0.9 10.7 0.6 Camp Conoy 6.7 Kenwood Beach 1

Distance and direction from the central point of the two containment buildings.

OFFSITE DOSE CALCULATION MANUAL Rev.

Page 00802 309 of 318 4 Radiological Environmental Monitoring Program Surveillances for Direct Radiation (1)

(2)

Each sample point shall be monitored using two or more dosimeters OR one instrument for measuring and recording dose rate continuously.

LLD for TLDs used for environmental measurements shall be in accordance with the recommendations of Regulatory Guide 4.13.

OFFSITE DOSE CALCULATION MANUAL Rev.

Page 00802 310 of 318 5 Radiological Environmental. Monitoring Program Surveillances for Airborne Activity RADIOIODINE CANNISTER PARTICULATE FILTER (1)

PARAMETER UNITS FREQUENCY LLD ACTION LEVEL (5)

Gross Beta Activity pCi/m 3 at least weekly (2) 0.01 N/A (3)

Cs-134 pCi/m 3 at least quarterly (4) 0.05 10.0 Cs-1 37 pCi/m 3 at least quarterly (4) 0.06 20.0 (1)

All samples consist of continuous sampler operation with sample collection weekly, or more frequently if required by dust loading.

(2)

Analyze for gross beta activity 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or more after sampling to allow for radon and thoron daughter decay.

(3)

Although there is not an ACTION Level for gross beta activity, if this parameter is greater than ten times the yearly mean of the control sample, perform GAMMA ISOTOPIC ANALYSIS on the individual sample.

(4)

Perform a GAMMA ISOTOPIC ANALYSIS of a quarterly COMPOSITE SAMPLE. A separate COMPOSITE SAMPLE shall be prepared for each sample location, Al thru A5. Each COMPOSITE SAMPLE shall be a prepared from individual particulate filter samples collected during the applicable calendar quarter and from a single location.

(5)

If an ACTION Level is exceeded, check the initiating conditions listed in Radiological Environmental Monitoring Program section 5.c and Radiological Environmental Monitoring Program section 5.d, and perform the corrective actions specified in Radiological Environmental Monitoring Program section 7.d and/or Radiological Environmental Monitoring Program section 7.e.

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 311 of 318 6 Radiological Environmental Monitoring Program Surveillances for Waterborne Activity SURFACE WATER SAMPLE (1)

PARAMETER UNITS FREQUENCY LLD ACTION LEVEL (2)

H-3 pCi/I at least quarterly 2000(3.)

20,000(')

Mn-54 pCi/I at least monthly 15 1000 Fe-59 pCi/I at least monthly 30 400 Co-58 pCi/I at least monthly 15 1000 Co-60 pCi/I at least monthly 15 300 Zn-65 pCi/I at least monthly 30 300 Zr-95 I Nb-95 pCi/I at least monthly 15 400 1-131 pCi/I at least monthly 1( 5) 2 Cs-1 34 pCi/I at least monthly 15 30 Cs-137 pCi/I at least monthly 18 50 Ba-140 / La-140 pCi/I at least monthly 15 200 SHORELINE SEDIMENT SAMPLE PARAMETER UNITS FREQUENCY LLD ACTION LEVEL (2)

Cs-1 34 pCi/kg, dry at least semiannually 150 N/A Cs-1 37 pCi/kg, dry at least semiannually 180 N/A (1)

(2)

(3)

(4)

(5)

The water sample shall be a composite of individual samples collected over a 1 month period.

If an ACTION Level is exceeded, check the initiating conditions listed in sections REMP SECTION 5.c and REMP SECTION 5.d, and perform the corrective actions specified in section REMP SECTION 7.d and/or REMP SECTION 7.e.

If a drinking water pathway does not exist, a value of 3000 pCi/I may be used.

If a drinking water pathway does not exist, a value of 30,000 pCi/I may be used.

LLD for drinking water samples. If no drinking water pathway exists, the LLD of thegamma isotopic analysis may be used.

S OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 312 of 318 7 Radiological Environmental Monitoring Program Surveillances for Ingestible Activity FISH AND INVERTEBRATES (1)

MILK FOOD P PARAMETER UNITS FREQUENCY LLD ACTION LEVEL (5)

Mn-54 pCi/kg, wet (2) 130 30,000 Fe-59 pCi/kg, wet (2) 260 10,000 Co-58 pCi/kg, wet (2) 130 30,000 Co-60 pCi/kg, wet (2) 130 10,000 Zn-65 pCi/kg, wet (2) 260 20,000 Cs-1 34 pCi/kg, wet (2) 130 1000 Cs-1 37 pCi/kg, wet (2) 150 2000 PARAMETER UNITS FREQUENCY LLD ACTION LEVEL (5) 1-131 pCi/I, wet atfleast monthly (4) 1 3

Cs-134 pCi/I, wet at least monthly (4) 15 60 Cs-i 37 pCi/I, wet at least monthly (4) 18 70, Ba-140 / La-140 pCi/I, wet at least monthly (4) 15 300

'RODUCTS PARAMETER UNITS FREQUENCY LLD ACTION LEVEL (5) 1-131 pCi/kg, wet at least monthly(3) 60 100 Cs-1 34 pCi/kg, wet

. at least monthly(3) 60 1000 Cs-1 37 pCi/kg, wet at least monthly(3) 80 2000 (1)

(2)

(3)

(4)

(5)

Edible portions of the fish and invertebrates shall be used for analysis.

The fish and invertebrates shall be sampled at 'least once per year in season, or semiannually if they are not seasonal.

The food products shall be sampled during the growing season.

The milk samples need be collected and analyzed only if the milk is commercially available in quantities greater than 310 liters per year (see NUREG-0133, 5.3.1.1).

If an ACTION Level is exceeded, check the initiating conditions listed in Radiological Environmental Monitoring Program section 5.c and Radiological Environmental Monitoring Program section 5.d, and perform the corrective actions specified in Radiological Environmental Monitoring Program section 7.d and/or Radiological Environmental Monitoring Program section 7.e..

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 313 of 318 Sites for REMP (5 Km Radius)

Rev.

00802 OFFSITE DOSE CALCULATION MANUAL Page 314 of 318 9 Map of Environmental Monitoring Sites for REMP (10 Mile Radius)

.L

.........~

tt T

F",.<-.

"La

" *i.-

[

,, am

Rev.

00802 OFFSITE DOSE CALCULATIONMANUAL Page 315 of 318 0 Environmental Monitoring Sites for ISFSI DESCRIPTION DISTANCE1 DIRECTION 1 (Kilometers)

(Sector)

AIR SAMPLERS AlT

  • SFA1 SFA2 SFA3 SFA4 TLD LOCATIONS SFDR1 SFDR2 SFDR3 SFDR4 SFDR5 SFDR6 SFDR7 SFDR8 SFDR9 SFDR10 SFDR11 SFDR12
SFDR13, SFDR14 SFDR15 SFDR16 DR7 2

DR30 SFDR17 SFDR18 VEGETATION SFbl SFb2 SFb3 SFb4 SFb5 SOIL SFS1 SFS2 SFS3 SFS4 SFS5 On Site Before Entrance'to Camp Conoy Meteorological Station CCNPP Visitor's Center North Northwest of ISFSI SSE of ISFSI Southwest of ISFSI North of ISFSI North of ISFSI Northeast of ISFSI East of ISFSI East Southeast of ISFSI CCNPP Visitors Center North Northwest of ISFSI SSE of ISFSI Northwest of ISFSI West Northwest of ISFSI WSW of ISFSI South of ISFSI Southeast of ISFSI East Northeast of ISFSI Southwest of ISFSI On Site Before Entrance to Camp Conoy Meteorological Station NNE OF ISFSI West OF ISFSI Meteorological Station CCNPP Visitor's.Center North Northwest of ISFSI SSEof ISFSI On Site Before Entrance to Camp Conoy Meteorological Station CCNPP Visitor's Center North Northwest of ISFSI SSE of ISFSI.

On Site Before Entrance to Camp Conoy 0.3 0.3 0.8 0.1 0.1 0.2 0.2

.0.1

<0.1

<0.1 0.1 0.8 0.1 0.1 0.1 0.1

<0.1

<0.1 0.1

<0.1

<0.1 0.3 0.3 0.1 0.04 0.3.

0.8 0.1 0.1 0.3 0.3 0.8 0.1 0.1 0.3 ESE NW N

NNW SSE SW N

N NE E

ESE N

NNW SSE NW WNW WSW S

SE ENE SW ESE NW NNE W

NW N

NNW SSE ESE NW N

NNW SSE ESE I

Distance and direction from the Central Point of the ISFSI.

2 Common to both the REMP and the ISFSIMP..

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 316 of 318 Map of Environmental Monitoring Sites for ISFSI

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page 317 of 318 2 Map of Environmental Monitoring Sites for ISFSI (ENLARGED)

A = Air Sampler (Plant)

DR = Direct Radiation (Plant)

SFDR = Direct Radiation (Spent Fuel)

SFA " Air Sampler (Spent Fuel)

PIC = Pressurized Ion Chamber SFS = Soil (Spent Fuel)

SFb = Vegetation (Spent Fuel)

OFFSITE DOSE CALCULATION MANUAL Rev.

00802 Page-318 of 318 3 Effluent Radiation Monitors Description Radiation Radiation Element Indicator Liquid Waste Discharge Radiation Monitor O-RE-2201 0-RI-2201 Steam Generator Blowdown Effluent Radiation Monitor 1-RE-4095 1-RI-4095 Steam Generator Blowdown Effluent Radiation Monitor 2-RE-4095 2-RI-4095 Steam Generator Blowdown Tank Radiation Monitor 1-RE-4014 1-RI-4014 Steam Generator Blowdown Tank Radiation Monitor 2-RE-4014 2-RI-4014 Wide Range Gas Monitor, Low Range 1-RE-5416 1-RIC-5415 Wide Range Gas Monitor, Low Range 2-RE-5416 2-RIC-5415 Westinghouse Plant Vent Stack Monitor 1-RE-5415 1-RI-5415 Westinghouse Plant Vent Stack Monitor 2-RE-5415 2-RI-5415 GASEOUS RADWASTE PROCESSING SYSTEM Radiation 0-RE-2191 0-RE-2191 Monitor Accident Monitors Not Addressed By The ODCM Wide Range Gas Monitor, Mid Range 1-RE-5417 Wide Range Gas Monitor, High Range 1-RE-5418 Wide Range Gas Monitor, Mid Range 2-RE-5417 Wide Range Gas Monitor, High Range 2-RE-5418