ML12090A752

From kanterella
Jump to navigation Jump to search
Entergy Pre-Filed Hearing Exhibit ENT000417 - LRA Plant Drains Unit 3 Diagram (Jan. 2012) Aerial Photo
ML12090A752
Person / Time
Site: Indian Point  
Issue date: 01/09/2012
From:
Entergy Corp, Indian Point
To:
Atomic Safety and Licensing Board Panel
SECY RAS
Shared Package
ML12090A727 List:
References
RAS 22156, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01
Download: ML12090A752 (1)


Text

Condensate Storage Tank Unit 3 Appendix R Fuel Oil Storage Tank(ARDG-FO-ST)

Fuel Oil Tank Fuel Oil Tank Fuel Oil Tank Drain Collection Tank Floor Drain Blow Down Tank Turbine Bldg.

Containment Bldg.

Primary Aux. Bldg.

Fan House Fuel Storage Bldg.

Diesel Generator Bldg.

Outage Support Bldg.

Aux. Feedwater Bldg. U3 Control Bldg. Unit 3 House Service Boiler Bldg.

Tech Support/Service Admin. Bldg.

Feed Reg Valve Annex U3 Turbine No. 1 Overhead Pipe Bridge Radioactive Machine Shop 4" Floor Drain 15 8" Floor Drain 3 8" Floor Drain 2 4" Floor Drain 9 4" Floor Drain 6 12" Floor Drain 3 4" Floor Drain 11 4" Floor Drain 13

+/-

0 10 20 30 40 5

Feet No Date Revision DRFTRCHK'D VER ENGR 1 1/9/2012 LRA Reviewed and Validated SB AA SI JP Buried Piping Integrity Management Program Westchester, NY Indian Point Energy Center (303) 792-0077 www.structint.com LRA Plant Drains Unit-3 LRA Plant Drains Unit 3 System Name EndStatonSource Plant Drains 4" Floor Drain 16 13 9321-F-22363_U3 Plant Drains 4" Floor Drain 5 5 9321-F-26963 Plan Elev 15 f Plant Drains 3" Floor Drain 1 5 9321-F-26963 Plan Elev 15 f Plant Drains 4" Floor Drain 13 10 9321-F-26963 Plan Elev 15 f Plant Drains 4" Floor Drain 15 137 9321-F-22363_U3 Plant Drains 8" Floor Drain 2 80 9321-F-40463 Plant Drains 12" Floor Drain 3 37 9321-F-41643_U3 Plant Drains 8" Floor Drain 4 7 9321-F-41643_U3 Plant Drains 4" Floor Drain 11 33 9321-F-26963 Plan Elev 15 f Plant Drains 12" Floor Drain 4 11 9321-F-22363_U3 Plant Drains 4" Floor Drain 14 30 9321-F-26963 Plan Elev 15 f Plant Drains 4" Floor Drain 2 5 9321-F-26963 Plan Elev 15 f Plant Drains 8" Floor Drain 3 141 9321-F-40463 Plant Drains 3" Floor Drain 3 5 9321-F-26963 Plan Elev 15 f Plant Drains 4" Floor Drain 8 11 9321-F-26963 Plan Elev 15 f Plant Drains 4" Floor Drain 10 14 9321-F-41643_U3 Plant Drains 4" Floor Drain 6 37 9321-F-26963 Plan Elev 15 f Plant Drains 3" Floor Drain 2 4 9321-F-26963 Plan Elev 15 f Plant Drains 4" Floor Drain 7 27 9321-F-26963 Plan Elev 15 f Plant Drains 4" Floor Drain 17 13 9321-F-22363_U3 Plant Drains 4" Floor Drain 12 30 9321-F-26963 Plan Elev 15 f Plant Drains 8" Floor Drain 1 110 9321-F-40463 Plant Drains 4" Floor Drain 9 42 9321-F-26963 Plan Elev 15 f ENT000417 Submitted: March 30, 2012