Entergy Pre-Filed Hearing Exhibit ENT000421 - LRA Service Water Unit 3 Diagram (Jan. 2012) Aerial Photo
ML12090A733
Person / Time
Site: Indian Point  
Issue date: 01/09/2012
From:
Entergy Corp, Indian Point
To:
Atomic Safety and Licensing Board Panel
SECY RAS
Shared Package
ML12090A727 List:
References
RAS 22156, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01
Download: ML12090A733 (1)


Text

Turbine Bldg.

Super Heater Bldg.

Unit No 2 Turbine Bldg.

Containment Bldg.

Service Bldg.

Heater Bay U3 Unit No 1 Screenwell House Condensate Polisher Facility Unk. Bldg. - 1 Intake Structure Enclosure Bldg.

Outage Support Bldg.

Security Bldg.

Primary Aux. Bldg.

Tech Support/Service Admin. Bldg.

Service Boiler Bldg.

Diesel Generator Bldg.

Control Bldg. Unit 3 Turbine No. 1 House Service Boiler Bldg.

Fan House Feed Reg Valve Annex U3 Aux. Feedwater Bldg. U3 Overhead Pipe Bridge Smoke Stack 24" Service Water 7 (Line #409) 10" Service Water 3 10" Service Water 4 (Line #1093) 16" Service Water 5 24" Service Water 8

+/-

0 30 60 90 120 15 Feet Heater Bay U3 Unk. Bldg. - 1 24" Service Water 3 (Line No. 408-1) 10" Service Water 8 16" Service Water 5 16" Service Water 3 (Line #1219) 10" Service Water 6 (Line #1221) 16" Service Water 4 (Line #1220) 10"Service Water 7 (Line #1222) 24" Service Water 7 (Line #409)

Turbine Bldg.

24" Service Water 7 (Line #409) 24" Service Water 5 (Line No. 712) 24" Service Water 3 (Line No. 408-1) 24" Service Water 8 LRA Service Water Unit 3 Outage Support Bldg.

Control Bldg. Unit 3 Diesel Generator Bldg.

10" Service Water 10 10" Service Water 4 (Line #1093) 10" Service Water 9 (line 1096 - 1)

System Name EndStatonSource Service Water 10" Service Water 5 (Line #1096) 179 9321-F-22363_U3 Service Water 24" Service Water 7 (Line #409) 664 9321-F-41643_U3 Service Water 24" Service Water 3 (Line No. 408-1) 677 9321-F-41643_U3 Service Water 6" Service Water 6 (Line 1097) 2 9321-F-22573 Service Water 16" Service Water 4 (Line #1220) 13 9321-F-22853_U3 Service Water 24" Service Water 6 (Line No. 405) 169 9321-F-22363_U3 Service Water 8" Service Water 2 (Raw Water Strainer) 77 9321-F-22853_U3 Service Water 10" Service Water 4 (Line #1093) 286 9321-F-22363_U3 Service Water 6" Service Water 5 (Line 1096 2) 5 9321-F-22573 Service Water 24" Service Water 5 (Line No. 712) 68 9321-F-27033 Service Water 10" Service Water 3 161 9321-F-22363_U3 Service Water 10" Service Water 10 125 9321-F-22573 Service Water 24" Service Water 8 23 9321-F-27033 Service Water 6" Service Water 3 (Line 1094) 2 9321-F-22573 Service Water 10" Service Water 8 47 9321-F-20973 Valve Pit Service Water 6" Service Water 7 (Line 1100) 2 9321-F-22573 Service Water 6" Service Water 2 (Line 1099 -1) 20 9321-F-22573 Service Water 6" Service Water 4 (Line 1096 1) 7 9321-F-22573 Service Water 10"Service Water 7 (Line #1222) 15 9321-F-22853_U3 Service Water 16" Service Water 5 50 9321-F-20973 Valve Pit Service Water 3" Service Water 2 101 9321-F-22363_U3 Service Water 6" Service Water 1 (Line 1093 -2) 16 9321-F-22573 Service Water 3" Service Water 3 (Supply) 102 9321-F-22363_U3 Service Water 3" Service Water 1 105 9321-F-22363_U3 Service Water 10" Service Water 9 (line 1096 - 1) 94 9321-F-22573 Service Water 16" Service Water 3 (Line #1219) 25 9321-F-22853_U3 Service Water 10" Service Water 6 (Line #1221) 13 9321-F-22853_U3 No Date Revision DRFTRCHK'D VER ENGR 1 1/9/2012 LRA Reviewed and Validated SB AA SI JP Buried Piping Integrity Management Program Westchester, NY Indian Point Energy Center (303) 792-0077 www.structint.com LRA Service Water Unit 3 ENT000421 Submitted: March 30, 2012