ML12090A747

From kanterella
Jump to navigation Jump to search
Entergy Pre-Filed Hearing Exhibit ENT000420 - LRA Service Water Unit 2 Diagram (Feb. 2012) Aerial Photo
ML12090A747
Person / Time
Site: Indian Point  
Issue date: 02/29/2012
From:
Entergy Corp, Indian Point
To:
Atomic Safety and Licensing Board Panel
SECY RAS
Shared Package
ML12090A727 List:
References
RAS 22156, 50-247-LR, 50-286-LR, ASLBP 07-858-03-LR-BD01
Download: ML12090A747 (1)


Text

Unit No 2 Turbine Bldg.

Super Heater Bldg.

Heater Bay Service Bldg.

Containment Bldg. Unit No 2 Fan House Primary Aux. Bldg.

Unit No 1 Screenwell House Nuclear Service Bldg.

Fuel Storage Bldg.

Unit No 2 Screenwell Structure Service Boiler Bldg.

Maintenance Storage Bldg.

Aux. Feedwater Bldg. U2 Feed Reg Valve Annex U2 Diesel Generator Bldg.

Overhead Pipe Bridge Smoke Stack Maintenance & Outage Bldg.

Containment Bldg. Unit No. 1 24" Service Water 2 (Line No. 408-2) 24" Service Water 4 (Line No. 409) 8" Service Water 1 16" Service Water 1 24" Service Water 1 16" Service Water 2 10" Service Water 1 10" Service Water 2 20" Service Water 1 18" Service Water 1 (Pipe Sleeve)

+/-

0 20 40 60 80 10 Feet No Date Revision DRFTRCHK'D VER ENGR 1 1/9/2012 LRA Reviewed and Validated SB AA SI JP Buried Piping Integrity Management Program Westchester, NY Indian Point Energy Center (303) 792-0077 www.structint.com LRA Service Water Unit 2 16" Service Water 1 16" Service Water 2 10" Service Water 1 24" Service Water 4 (Line No. 409) 10" Service Water 2 24" Service Water 2 (Line No. 408-2)

Fan House 24" Service Water 1 20" Service Water 1 8" Service Water 1 24" Service Water 2 (Line No. 408-2)

LRA Service Water Unit 2 System Name EndStatonSource Service Water 16" Service Water 1 50 9321-2700_U2 Service Water 20" Service Water 1 45 9321-2700_U2 Service Water 8" Service Water 1 146 9321-2236_U2 Service Water 24" Service Water 2 (Line No. 408-2) 676 9321-4005_U2 Enlarged, 9321-2700_U2 Service Water 24" Service Water 4 (Line No. 409) 651 9321-4005_U2 Enlarged, 9321-2700_U2 Service Water 18" Service Water 1 (Pipe Sleeve) 62 9321-2259 Service Water 10" Service Water 1 45 9321-2700_U2 Service Water 24" Service Water 1 175 9321-4005_U2 Enlarged, 9321-2700_U2 Service Water 10" Service Water 2 42 9321-2700_U2 Service Water 16" Service Water 2 46 9321-2700_U2 ENT000420 Submitted: March 30, 2012