IR 05000184/2008201

From kanterella
(Redirected from ML081190339)
Jump to navigation Jump to search
IR 05000184-08-201, on 04/15-18/2008, National Institute of Standards and Technology (NIST) Center for Neutron Research
ML081190339
Person / Time
Site: National Bureau of Standards Reactor
Issue date: 04/29/2008
From: Johnny Eads
NRC/NRR/ADRA/DPR/PRTB
To: Gallagher P
US Dept of Commerce, National Institute of Standards & Technology (NIST)
Voth M, NRR/ADRA/DPR/PRT, 415-1210
References
IR-08-201
Download: ML081190339 (16)


Text

ril 29, 2008

SUBJECT:

NRC INSPECTION REPORT NO. 50-184/2008-201

Dear Dr. Gallagher:

This letter refers to the inspection conducted on April 15 to 18, 2008, at your Research Reactor Facility. The inspection included a review of activities authorized for your facility. The enclosed report presents the results of that inspection.

Areas examined during the inspection are identified in the report. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations of activities in progress. Based on the results of this inspection, no safety concern or noncompliance of Nuclear Regulatory Commission (NRC)

requirements was identified. No response to this letter is required.

In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC=s Agencywide Document Access Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Should you have any questions concerning this inspection, please contact Marcus Voth at 301-415-1210.

Sincerely,

/RA/

Johnny H. Eads, Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-184 License No. TR-5 Enclosure: NRC Inspection Report No. 50-184/2008-201 cc w/ enclosure:

See next page

National Institute of Standards and Technology Docket No. 50-184 cc:

Environmental Program Manager III Radiological Health Program Air & Radiation Management Adm.

Maryland Dept of the Environment 1800 Washington Blvd, Suite 750 Baltimore, MD 21230-1724 Director, Department of State Planning 301 West Preston Street Baltimore, MD 21201 Director, Air & Radiation Management Adm.

Maryland Dept of the Environment 1800 Washington Blvd., Suite 710 Baltimore, MD 21230 Director, Department of Natural Resources Power Plant Siting Program Energy and Coastal Zone Administration Tawes State Office Building Annapolis, MD 21401 President Montgomery County Council 100 Maryland Avenue Rockville, MD 20850 Dr. Wade Richards, Manager of Operations and Engineering NIST Center for Neutron Research National Institute of Standards and Technology U.S. Department of Commerce 100 Bureau Drive, Mail Stop 8561 Gaithersburg, MD 20899-8561 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611

April 29, 2008 Dr. Patrick