BSEP 06-0129, Request for License Amendments Regarding Linear Heat Generation Rate and Core Operating Limits Report References for Areva Np Fuel

From kanterella
(Redirected from ML070300570)
Jump to navigation Jump to search

Request for License Amendments Regarding Linear Heat Generation Rate and Core Operating Limits Report References for Areva Np Fuel
ML070300570
Person / Time
Site: Brunswick  Duke Energy icon.png
Issue date: 01/22/2007
From: Scarola J
Progress Energy Carolinas
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
BSEP 06-0129, TSC-2006-06
Download: ML070300570 (119)


Text

James Scarola SProgress Energy Vc rsdn Brunswick Nuclear Plant Progress Energy Carolinas, Inc.

JAN 2 22007 SERIAL: BSEP 06-0 129 10 CER 50.90 TSC-2006-06 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

Subject:

Brunswick Steam Electric Plant, Unit Nos. 1 and 2 Docket Nos. 50-325 and 50-324/License Nos. DPR-71 and DPR-62 Request for License Amendments Regarding Linear Heat Generation Rate and Core Operating Limits Report References for ARE VA NP Fuel Ladies and Gentlemen:

In accordance with the Code of Federal Regulations, Title 10, Part 50.90, Carolina Power & Light Company (CP&L), now doing business as Progress Energy Carolinas, Inc.,

is requesting a revision to the Technical Specifications (TSs) for the Brunswick Steam Electric Plant (BSEP), Unit Nos. 1 and 2. The proposed license amendments revise:

(1) Technical Specification 5.6.5, "Core Operating Limits Report (COLR)," to add references to ARE VA NP analytical methods that will be used to determine core operating limits, and (2) add a new Technical Specification 3.2.3, "Linear Heat Generation Rate (LHGR)," add a new definition to Technical Specification 1. 1 for LHGR, and revise Technical Specifications 3.4.1 and 3.7.6 to incorporate restrictions on LHGR when in single recirculation loop operation or with an inoperable Turbine Bypass System. An evaluation of the proposed license amendments is provided in Enclosure 1.

CP&L has evaluated the proposed change in accordance with 10 CER 50.9 1(a)(1), using the criteria in 10 CER 50.92(c), and determined that this change involves no significant hazards considerations.

CP&L is providing, in accordance with 10 CER 50.9 1(b), a copy of the proposed license amendment to the designated representative for the State of North Carolina.

CP&L requests approval of the proposed amendments by January 30, 2008. Once approved, the Unit 1 amendment shall be implemented prior to start-up from the 2008 Unit 1 refueling outage and the Unit 2 amendment shall be implemented prior to start-up from the 2009 Unit 2 refueling outage.

There are no regulatory commitments associated with this submittal. Please refer any questions regarding this submittal to Mr. Randy C. Ivey, Manager - Support Services, at (910) 457-2447.

P.O. Boo 10429 Southport, NC 28461Cc T> 910.457.3698 F> 910.457.2803

Document Control Desk BSEP 06-0 129 / Page 2 I declare, under penalty of perjury, that the foregoing is true and correct. Executed on January 22, 2007.

Sincerely, 7James Scarola WRM/wrm

Enclosures:

1. Evaluation of Proposed License Amendment Requests

2. ARE VA NP BWR Approved Topical Reports for Brunswick Units 1 and 2 Technfical Specification COLR References
3. GNIF BWR Approved Topical Reports for Brunswick Units 1 and 2 Technical Specification COLRZ References
4. Marked-up Technical Specification Pages - Unit 1
5. Typed Technical Specification Pages - Unit 1
6. Typed Technical Specification Pages - Unit 2
7. Marked-up Technical Specification Bases Pages - Unit 1 (For Information Only)

Docume--it Control Desk BSEP 06-0129 / Page 3 cc (with enclosures):

U. S. Nuclear Regulatory Commission, Region II ATTN: Dr. William D. Travers, Regional Administrator Sam Nunn Atlanta Federal Center 61 Forsyth Street, SW, Suite 23T85 Atlanta, GA 30303-8931 U. S. Nuclear Regulatory Commission ATTN: Mr. Eugene M. DiPaolo, NRC Senior Resident Inspector 8470 River Road Southport, NC 28461-8869 U. S. Nuclear Regulatory Commission (Electronic Copy Only)

ATTN: Mr. Stewart N. Bailey (Mail Stop OWEN 8B1) 11555 Rockville Pike Rockville, MD 20852-2738 Ms. Jo A. Sanford Chair - North Carolina Utilities Commission P.O. Box 29510 Raleigh, NC 27626-05 10 Ms. Beverly 0. Hall, Section Chief Radiation Protection Section, Division of Environmental Health North Carolina Department of Environment and Natural Resources 3825 Bar-rett Drive Raleigh, NC 27609-7221

BSEP 06-0 129 Enclosure I Page 1 of 12 Evaluation of Proposed License Amendment Requests

Subject:

Request for License Amendments Regarding Linear Heat Generation Rate Requirements and Core Operating Limits Report References for ARE VA NP Fuel 1.0 Description This letter is a request by Carolina Power & Light Company (CP&L), now doing business as Progress Energy Carolinas, Inc., to amend the Technical Specifications of Renewed Operating Licenses DPR-71 and DPR-62 for the Brunswick Steam Electric Plant (BSEP),

Unit Nos. 1 and 2.

The proposed license amendments will revise: (1) Technical Specification 5.6.5, "Core Operating Limits Report (COLR)," to add references to ARE VA NP analytical methods that will be used to determine core operating limits, and (2) add a new Technical Specification 3.2.3, "Linear Heat Generation Rate (LHGR)," add a new definition to Technical Specification 1. 1 'for LHGR, and revise Technical Specifications 3.4.1 and 3.7.6 to incorporate restrictions on LHGR when in single recirculation loop operation or with an inoperable Turbine Bypass System.

These proposed Technical Specification changes are needed to support the transition to ARE VA NP fuel, and to ARE VA NP core design and analysis services. CP&L is planning to begin using AREVA NP fuel starting with the BSEP, Unit 1 refueling outage scheduled for March 2008 and the BSEP, Unit 2 refueling outage scheduled for February 2009.

2.0 Proposed Changes Core Operating Limits Report Methodologies Technical Specification 5.6.5, "Core Operating Limits Report (COLR)," item b, is being revised as shown below. The specific changes to Technical Specification 5.6.5, item b, are shown in bold typeface.

b.

The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC, specifically those described in the following documents:

1.

NEDE-2401 1-P-A, General Electric Standard Application for Reactor Fuel.

2.

XN-NF-81 -58(P)(A), RODEX2 Fuel Rod Thermal-Mechanical Response Evaluation Model.

BSEP 06-0129 Page 2 of 12

3.

XN-NF-85-67(P)(A), Generic Mechanical Design for Exxon Nuclear Jet Pump BWR. Reload Fuel.

4.

EMF-85-74(P) Supplement 1(P)(A) and Supplement 2(P)(A),

RODEX2A (BWR) Fuel Rod Thermal-Mechanical Evaluation Model.

5.

ANF-89-98(P)(A), Generic Mechanical Design Criteria for BWR Fuel Designs.

6.

XN-NF-80-19(P)(A) Volume 1, Exxon Nuclear Methodology for Boiling Water Reactors - Neutronic Methods for Design and Analysis.

7.

XN-NF-80-19(P)(A) Volume 4, Exxon Nuclear Methodology for Boiling Water Reactors: Application of the ENC Methodology to BWR Reloads.

8.

EMF-2158(P)(A), Siemens Power Corporation Methodology for Boiling Water Reactors: Evaluation and Validation of CASMO-4/MICROBURN-B2.

9.

XN-NF-80-19(P)(A) Volume 3, Exxon Nuclear Methodology for Boiling Water Reactors, THERMEX: Thermal Limits Methodology Summary Description.

10.

XN-NF-84-105(P)(A) Volume 1, XCOBRA-T: A Computer Code for BWR Transient Thermal-Hydraulic Core Analysis.

11.

ANF-524(P)(A), ANF Critical Power Methodology for Boiling Water Reactors.

12.

ANF-913(P)(A) Volume 1, COTRANSA2: A Computer Program for Boiling Water Reactor Transient Analyses.

13.

ANF-1358(P)(A), The Loss of Feedwater Heating Transient in Boiling Water Reactors

14.

EM[F-2209(P)(A), SPCB Critical Power Correlation.

15.

EMF-2245(P)(A), Application of Siemens Power Corporation's Critical Power Correlations to Co-Resident Fuel.

16.

EMF-2361(P)(A), EXEM BWR-2000 ECCS Evaluation Model.

BSEP 06-0129 Page 3 of 12

17.

EMF-2292(P)(A), ATRIUMTM-10: Appendix K Spray Heat Transfer Coefficients.

18.

EMiF-CC-074(P)(A) Volume 4, BWR Stability Analysis:

Assessment of STAIF with Input from MICROBURN-B2.

19.

NEDO-32465-A, Reactor Stability Detect and Suppress Solutions Licensing Basis Methodology for Reload Applications.

Linear Heat Generation Rate First, a new definition for LHGR is being added to Technical Specification 1. 1, "Definitions."

LINEAR HEAT GENERATION RATE (LHGR)

The LHGR shall be the heat generation rate per unit length of fuel rod. It is the integral of the heat flux over the heat transfer area associated with the unit length.

Second, a new Technical Specification 3.2.3, "Linear Heat Generation Rate (LHGR)," is being added, as shown below.

3.2.3 LINEAR BEAT GENERATION RATE (LHGR)

LCO 3.2.3 All LHGRs shall be less than or equal to the limits specified in the COLR.

APPLICABILITY:

THERMAL POWER Ž:23% RTP.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

Any LHGR not within A.1 Restore LHGR(s) to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />

limits, within limits.

B.

Required Action and B. 1 Reduce THERMAL 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> associated Completion POWER to Time not met.

< 23% RTP.

BSEP 06-0 129 Page 4 of 12 SURVEILLANCE REQUIREMENTS__________

SURVEILLANCE FREQUENCY SR 3.2. 1.1 Verify all LHGRs are less than or Once within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after equal to the limits specified in the

>Ž 23% RTP COLR.

AND 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter Third, Technical Specification 3.4.1, "Recirculation Loops Operating," is being revised as shown below. The specific changes to Technical Specification 3.4.1 are shown in bold typeface.

3.4.1 Recirculation Loops Operating LCO 3.4.1 Two recirculation loops with matched recirculation pump speeds shall be in operation, OR One recirculation loop may be in operation provided the following limits are applied when the associated LCO is applicable:

a.

LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)," single loop operation limits specified in the COLR;

b.

LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR),"

single loop operation limits specified in the COLR; and

c.

LCO 3.2.3, "LINEAR HEAT GENERATION RATE (LHGR)," single loop operation limits specified in the COLR; and

d.

LCO 3.3. 1. 1, "Reactor Protection System (RPS) Instrumentation,"

Function 2.b (Average Power Range Monitors Simulated Thermal Power-High), Allowable Value of Table 3.3.1.1-1 is reset for single loop operation.

BSEP 06-0129 Page 5 of 12 Fourth, Technical Specification 3.7.6, "The Main Turbine Bypass System," is being revised as shown below. The specific changes to Technical Specification 3.7.6 are shown in bold typeface.

3.7.6 The Main Turbine Bypass System LCO 3.7.6 The Main Turbine Bypass System shall be OPERABLE.

OR The following limits are made applicable:

a.

LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)," limits for an inoperable Main Turbine Bypass System, as specified in the COLR; and

b.

LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR),"

limits for an inoperable Main Turbine Bypass System, as specified in the COLR; and

c.

LCO 3.2.3, "LINEAR HEAT GENERATION RATE (LHGR)," limits for an inoperable Main Turbine Bypass System, as specified in the COLR.

Fifth, Technical Specification 5.6.5, "Core Operating Limits Report (COLR)," item a, is being revised as shown below. The specific changes to Technical Specification 5.6.5, item a, are shown in bold typeface.

a.

Core operating limits shall be established prior to each reload cycle, or prior to any remaining portion of a reload cycle, and shall be documented in the COLR for the following:

  • 1.

The AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR) for Specification 3.2.1;

2.

The MINIMUM CRITICAL POWER RATIO (MCPR) for Specification 3.2.2;

3.

The LINEAR HEAT GENERATION RATE (LHGR) for Specification 3.2.3;

BSEP 06-0 129 Page 6 of 12

4.

The period based detection algorithm (PBDA) setpoint for Function 2.f, Oscillation Power Range Monitor (OPRM)

Upscale, for Specification 3.3. 1. 1; and

5.

The Allowable Values and power range setpoints for Rod Block Monitor Upscale Functions for Specification 3.3.2. 1. contains a marked-up version of the Unit 1 Technical Specifications showing the proposed changes. Since the affected Technical Specification Sections (i.e., 1. 1, 3.2.3, 3.4. 1, 3.7.6, and 5.6.5 for Unit 1 and Unit 2 are identical, only the mark-up for Unit I is provided.

Enclosures 5 and 6 provide typed versions of the affected Unit 1 and Unit 2 Technical Specification pages, respectively. These typed Technical Specification pages are to be used for issuance of the proposed amendments.

CP&L will make supporting changes to the Technical Specification Bases in accordance with Technical Specification 5.5.10, "Technical Specifications (TS) Bases Control Program." provides a markup of the affected Technical Specification Bases pages for Unit 1. These pages are being submitted for information only and do not require issuance by the NRC.

3.0

Background

On March 10, 2006, CP&L held a public meeting with the NRC to discuss plans to change the Brunswick Unit 1 and 2 reload fuel supplier from Global Nuclear Fuels - Americas (GNF-A) to AREVA NP. A summary of this meeting was issued by the NRC on April 27, 2006 (i.e., Reference 1). As presented during the public meeting, CP&L plans included submittal of at least two separate license amendment applications to request the Technical Specification changes needed to support loading and use of the ATRllJMTM-10 fuel assemblies.

This letter provides the proposed Technical Specification changes necessary to incorporate the AREVA NP analytical methods, previously approved by the NRC, that will be used to establish core operating limits. Under a separate submittal (i.e., Reference 2), CP&L has submitted proposed Technical Specification changes needed to support the receipt and storage of new AREVA NP fuel bundles. If changes to the Minimum Critical Power Ratio (MCPR) Safety Limit (SL) values are required to support operation with the ATRIUMTM_ 10 fuel, CP&L anticipates submittal of those MCPR SL changes in July 2007.

CP&L plans to begin using ARE VA NP fuel beginning with the March 2008 Unit I refueling outage; therefore, CP&L requests that these Technical Specification changes be issued by January 30, 2008. Once approved, the Unit 1 amendment shall be implemented prior to start-up from the 2008 Unit 1 refueling outage and the Unit 2 amendment shall be implemented prior to start-up from the 2009 Unit 2 refueling outage.

BSEP 06-0129 Page 7 of 12 4.0 Technical Analysis Core Operating Limits Report Methodologies Currently, Technical Specification 5.6.5, "Core Operating Limits Report (COLR)," item b, identifies the NRC reviewed and approved analytical methods to be used to determine core operating limits. A revision to Technical Specification 5.6.5.b is needed to reference the ARE VA NP analytical methods that will be used in upcoming fuel cycles to determine core operating limits.

Each methodology reference being added is being cited consistent with the format established in TSTF-363, Revise Topical Report References in ITS 5.6.5, COLR, which was approved by the NRC on April 13, 2000. TSTF-363 has subsequently been incorporated into the latest NRC-approved version of the Standard Technical Specifications for BWRI4 plants (i.e., Revision 3.1 of NUREG-1433). NUREG-1433, Revision 3.1, states that: (1) Technical Specification 5.6.5.b should identify the topical report(s) by number and title or identify the staff Safety Evaluation Report for a plant-specific methodology by NRC letter and date, and (2) the COLR will contain the complete identification for each Technical Specification referenced topical report(s) used to prepare the COLR (i.e., report number, title, revision, date, and any supplements).

Brunswick Technical Specification 5.6.5.b contains an existing reference to the GNF-A topical report NEDE-2401 11-P-A, General Electric Standard Application for Reactor Fuel.

This analytical methodology reference is being retained because some GNEF-A-derived core operating limits will continue to be applicable to the co-resident GNF-A fuel. However, to maintain consistency with the form-at established in Revision 3 of NJIREG-1433, the existing phrase "(latest approved version)" is being removed from the Technical Specification 5.6.5.b reference to NEDE-24011I-P-A.

Brunswick Technical Specification 5.6.5.b also contains an existing reference to the GNF-A topical report NEDE-32906P-A, TRACG Application for Anticipated Abnormal Operational Occurrences (A 00) Transient Analyses. The TRACG analytical methodology was added to the Brunswick Technical Specifications through Amendments 231 (i.e., Reference 3) and 262 (i.e., Reference 4) for Units 1 and 2, respectively. At the time the TRACG analytical methodology was added to the Brunswick Technical Specifications, the TRACG method had not yet been incorporated into the GNF-A topical report NEDE-2401 I-P-A. The TRACG analytical methodology has subsequently been added to GNTF-A topical report NEDE-2401 I-P-A; therefore, the separate Technical Specification 5.6.5.b reference to GNIF topical report NEDE-32906P-A is no longer necessary and is being removed.

Finally, a reference to the GNF-A topical report NEDO-32465-A, Reactor Stability Detect and Suppress Solutions Licensing Basis Methodology for Reload Applications, is being added to Technical Specification 5.6.5.b. Although NEDO-32465-A has been incorporated into the

BSEP 06-0 129 Page 8 of 12 compendium of methods contained in GNF-A topical report NIEDE-2401 I1-P-A, the NEDO-32465-A topical report will be used by AREVA NP as part of their detection and suppression analyses. provides a list of the NRC-approved ARE VA NP topical report references being added to Technical Specification 5.6.5.b and the associated Technical Specification Limiting Condition for Operations for the core limits or setpoints for which the methodology is used. provides a list showing the applicability of the retained GNF-A topical report NEDE-24011-P-A reference to Technical Specification 5.6.5.a core operating limits. Details regarding the GNE-A methodologies for calculating core limits are available in NEDE-2401 I1-P-A-15.

Linear Heat Generation Rate The Brunswick Technical Specifications currently do not include LHGR as a required power distribution limit. The LHGR is a measure of the heat generation rate of a fuel rod in a fuel assembly at any axial location and is an important fuel design parameter. Limits are calculated for LHGR to ensure that the cladding circumferential plastic strain will not exceed one percent and that the fuel centerline will not melt. Thus, limits on the LHGR in the COLR are specified to ensure the fuel design limits are not exceeded anywhere in the core during normal operation, including anticipated operational occurrences.

For GNF-A fuel, the average planar linear heat generation rate (APLHGR) limits, in addition to protecting against excess peak clad temperature, include the exposure dependent thermal-mechanical limits for the fuel rods and thereby ensure that the LHGR limits are not exceeded.

During the upcoming BSEP mixed core cycles, the APLHGR limits that were developed by GNE-A for their fuel types will continue to be the applicable limits and will ensure that the LHGR limits for GNF-A fuel are not exceeded.

To support the use of ARE VA NP fuel, a new Technical Specification 3.2.3 is being proposed to add the LHGR limit as a separate limit. For ARE VA NP fuel, both the APLHGR and the LHGR limits will be specified in the COLR.

Currently, Technical Specification 3.4.1, Recirculation Loop Operating, and Technical Specification 3.7.6, Main Turbine Bypass System, contain equipment out-of-service provisions for adjusting APLHGR and MCPR limits to ensure thermal margins are maintained if certain equipment is not in service. The specific adjusted APLHGR and MCPR limits for these conditions are currently documented in the COLR. As part of the proposed amendments, a similar provision is being added to Technical Specification 3.4.1 and Technical Specification 3.7.6 to apply an adjustment to the LHGR limit when a single reactor recirculation loop or the main turbine bypass system is inoperable. The specific adjusted LHGR limits for these conditions will also be documented in the COLR.

BSEP 06-0 129 Page 9 of 12 5.0 Regulatory Safety Analysis 5.1 No Significant Hazards Consideration Carolina Power & Light Company (CP&L), now doing business as Progress Energy Carolinas, Inc., is submitting proposed amendments to support transition to AREVA NP fuel and core design and analysis services for the Brunswick Steam Electric Plant (BSEP),

Units I and 2. The proposed amendments: (1) revise Technical Specification 5.6.5, "Core Operating Limits Report (COLR)," to add references to AREVA NP analytical methods that will be used to determine core operating limits, and (2) add a new Technical Specification 3.2.3, 'Linear Heat Generation Rate (LHGR)," add a new definition to Technical Specification 1. 1 for LHGR, and revise Technical Specifications 3.4.1 and 3.7.6 to incorporate restrictions on LHGR when in single recirculation loop operation or with an inoperable Turbine Bypass System. CP&L has evaluated whether or not a significant hazards consideration is involved with the proposed amendments by focusing on the three standards set forth in 10 CER 50.92, "Issuance of amendment," as discussed below:

1.

Does the proposed change involve a significant increase in the probability or consequences of an accident previously evaluated?

Response: No The proposed amendments revise the list of NRC-approved analytical methods used to establish core operating limits. Core operating limits are established to ensure that fuel design limits are not exceeded during operating transients or accidents. The analytical methods used to determine core operating limits are those methods that have previously been found acceptable by the NRC and are required to be listed in the Technical Specification section governing the Core Operating Limits Report. The application of these NRC-approved analytical methods will continue to ensure that acceptable operating limits are established and applied to operation of the reactor core.

The proposed amendments will add a new Technical Specification 3.2.3, "Linear Heat Generation Rate (LHGR)," for fuel bundles, add a new definition to Technical Specification 1. 1 for LHGR, and revise Technical Specifications 3.4.1 and 3.7.6 to incorporate restrictions on LHGR when in single recirculation loop operation or with an inoperable Turbine Bypass System. These LHGR limits will be established using NRC-approved analytical methods to ensure that fuel performance during normal, transient, and accident conditions is acceptable.

Based on the above, the proposed amendments do not involve an increase in the probability or consequences of an accident previously evaluated.

BSEP 06-0129 Page 10 of 12

2.

Does the proposed change create the possibility of a new or different kind of accident from any accident previously evaluated?

Response: No As previously stated, the proposed amendments support transition from Global Nuclear Fuels - Americas (GNF-A) fuel and core design and analysis services to ARE VA NP fuel and core design and analysis services. The AREVA NP fuel assemblies which will be used in the BSEP Unit 1 and 2 cores will be similar in design to the GNF-A fuel that will be co-resident in the cores. The BSEP, Unit 1 and 2 cores in which this fuel will operate will be designed to meet all applicable design and licensing criteria.

Adherence to these design and licensing criteria will not introduce any new modes of operation or introduce any new accident precursors, and thus will preclude the introduction of a new or different kind of accident from any accident previously evaluated.

3.

Does the proposed change involve a significant reduction in a margin of safety?

Response: No The proposed amendments will continue to require that core operating limits be determined using NRC-approved analytical methods. Acceptable fuel performance is obtained by ensuring that the peak cladding temperature (PCT) during a postulated design basis loss-of-coolant accident (LOCA) is maintained less than the limits specified in 10 CER 50.46, and that the core remains in a coolable geometry following a postulated design basis LOCA. The proposed amendments ensure that adequate margin will continue to be maintained to the 2200 degree PCT limit of 10 CFR 50.46, and the use of NRC-approved analytical methods will continue to ensure acceptable fuel performance during normal operations, as well as during transient and accident conditions. Therefore, the proposed amendments do not involve a significant reduction in a margin of safety.

Based on the above, CP&L concludes that the proposed amendments present no significant hazards consideration under the standards set forth in 10 CFR 50.92(c), and, accordingly, a finding of "no significant hazards consideration" is justified.

5.2 Applicable Regulatory Reg uirements/Criteri a 10 CER 50.36, "Technical Specifications," provides the regulatory requirements for the content required in a licensee's Technical Specifications. Criterion 2 of 10 CFR 50.36(c)(2)(ii) requires a limiting condition for operation to be established for a process variable, design feature, or operating restriction that is an initial condition of a design

BSEP 06-0 129 Page 11 of 12 basis accident or transient analysis that either assumes the failure of or presents a challenge to the integrity of a fission product barrier.

10 CFR 50.46, "Acceptance criteria for emergency core cooling systems for light-water power reactors," establishes the acceptance criteria for the design basis LOCA.

Paragraph (b)(1) requires the calculated maximum fuel element cladding temperature (i.e.,

PCT) to not exceed 22000 FE The use of NRC-approved analytical methods to determine core operating limits will continue to ensure that fuel performance during normal, transient, and accident conditions complies with these requirements. Specific APLHGR limits will be determined and documented in the COLR to ensure compliance with 10 CER 50.46(b)(1).

LHGR is being added to the Technical Specifications to support Criterion 2 of 10 CFR 50.36(c)(2)(ii).

6.0 Environmental Considerations A review has determined that the proposed amendments would change a requirement with respect to installation or use of a facility component located within the restricted area, as defined in 10 CFR 20, or would change an inspection or surveillance requirement. However, the proposed amendments do not involve: (i) a significant hazards consideration, (ii) a significant change in the types or significant increase in the amounts of any effluent that may be released offsite, or (iii) a significant increase in individual or cumulative occupational radiation exposure. Accordingly, the proposed amendments meet the eligibility criterion for categorical exclusion set forth in 10 CFR 51.22(c)(9). Therefore, pursuant to 10 CER 51.22(b), no environmental impact statement or environmental assessment need be prepared in connection with the proposed amendments.

7.0 References

1. "Summary of March 10, 2006, Meeting with Carolina Power & Light Company (CP&L),

Regarding the Fuel Transition Process and Licensing Submittals for Brunswick Steam Electric Plant, Units 1 and 2," dated April 27, 2006, ADAMS Accession Number MLO6 1000574.

2. Letter from Mr. James Scarola (CP&L) to the Document Control Desk (NRC), "Request for License Amendments Regarding Fuel Design and Storage Requirements for AREVA NP Fuel," dated January 22, 2007.
3. Letter from Ms. Brenda L. Mozafari (NRC) to Mr. C. J. Gannon (CP&L), "Issuance of Amendment Re: Minimum Critical Power Ratio Safety Limit (TAC No. MC 1249),"

dated March 26, 2004, ADAMS Accession Number ML040900042.

BSEP 06-0129 Page 12 of 12

4. Letter from Ms. Brenda L. Mozafari (NRC) to Mr. C. J. Gannon (CP&L), "Issuance of Amendment on Addition of TRACG Methodology for Determining Core Operating Limits (TAC No. MC4385)," dated March 4, 2005, ADAMS Accession Number ML050470131.

BSEP 06-0 129 Page 1 of 4 AREVA NP BWR Approved Topical Reports for Brunswick Units 1 and 2 Technical Specification COLR References Report Applicable LCO Justification XN-NF-81-58(P)(A) Revision 2 and 3.2.1 /ATRllJMTM-10 Provides an analytical capability to predict Supplements 1 and 2, RODEX2 Fuel Rod 3.2.2 / ATRULJMTM-10, GE 14 BWR fuel thermal and mechanical conditions Thermal-Mechanical Response Evaluation 3.2.3 / ATRIUMTM-10 for normal core operation and to establish Model.

initial conditions for power ramping, non-LOCA and LOCA analyses.

XN-NF-85-67(P)(A) Revision 1, Generic 3.2.3 / ATRfLJMTM-10 Describes the process used to develop linear Mechanical Design for Exxon Nuclear Jet heat generation rates for fuel designs.

Pump BWR Reload Fuel.

EMI-85-74(P) Revision 0 3.2.3 / ATRJUMTM_ 10 Extends the exposure limit of the RODEX2A Supplement 1(P)(A) and code which is a version of RODEX2 that Supplement 2(P)(A), RODEX2A (BWR) includes a fission gas release model specific Fuel Rod Thermal-Mechanical Evaluation to BWR fuel designs.

Model.

AN-F-89-98(P)(A) Revision 1 and 3.2.3 / ATRfUMTM-10 Establishes a set of design criteria which Supplement 1, Generic Mechanical Design assures that BWR fuel will perform Criteria for BWR Fuel Designs.

____________________satisfactorily throughout its lifetime.

BSEP 06-0 129 Page 2 of 4 Report Applicable LCO Justification X.N-NF-80-19(P)(A) Volume 1 and 3.2.1 / ATRITJMTM-10 Development of BWR core analysis Supplements 1 and 2, Exxon Nuclear 3.2.2 / ATRTUMTM-10, GE14 methodology which comprises codes for fuel Methodology for Boiling Water Reactors -

3.2.3 / ATRIUMTM-10 neutronic parameters and assembly bumnup Neutronic Methods for Design and Analysis.

3.3.2. 1, Table 3.3.2. 1-1 /calculations, reactor core simulation diffusion ATRI1JlVTM-10, GE14 theory calculations, core and channel hydrodynamic stability predictions, and producing input for nuclear plant transients.

Subsequently approved codes or methodologies have superseded portions of this report. Applicable portions include control rod drop accident, and methodology to determine neutronic reactivity parameters, void reactivity, Doppler reactivity, scram reactivity, delayed neutron fraction, and prompt neutron lifetime.

XN-NF-80-19(P)(A) Volume 4 Revision 1, 3.2.1 / ATRIT1MTM-10 Summarizes the types of BWR licensing Exxon Nuclear Methodology for Boiling 3.2.2 / ATR~iJvLTN4M-10, GE14 analyses performed, identifies the Water Reactors: Application of the ENC 3.2.3 / ATRIUMTM-10 methodologies used.

Methodology to BWR Reloads.

EMF-2158(P)(A) Revision 0, Siemens 3.2.2 I ATRRTN/TM-10, GE14 Describes the reactor core simulator code Power Corporation Methodology for 3.2.3 I ATRHUMTM-10 MICROBURN-B2 and the lattice physics Boiling Water Reactors: Evaluation and 3.3.2. 1, Table 3.3.2. 1-1 Icode CASMO-4.

LValidation of CASMO-4/MICROBURN-B2.

ATRJUMTM-10, GEJ4

BSEP 06-0 129 Page 3 of 4 Report Applicable LCO Justification XN-NE-80-19(P)(A) Volume 3 Revision 2, 3.2.2 / ATRIUMTM-10, GE14 Provides overall methodology for determining Exxon Nuclear Methodology for Boiling a MCPR operating limit.

Water Reactors, THERMEX. Thermnal Limits Methodology Summary Description.

XN-NE-84-105(P)(A) Volume 1 and 3.2.2 / ATRIUMTM-10, GE14 Provides a capability to perform analyses of Volume 1 Supplements 1 and 2, transient heat transfer behavior in BWR XCOBRA-T: A Computer Code for BWR assemblies.

Transient Thennal-Hydraulic Core Analysis._____________________

ANF-524(P)(A) Revision 2 and 3.2.2 / ATR~IUMTM-10, GE14 Provides a methodology for the determination Supplements 1 and 2, ANF Critical Power of thermal margins, specifically the MCPR Methodology for Boiling Water Reactors.

safety limit.

ANEF-913(P)(A) Volume I Revision 1 and 3.2.2 / ATRRLTMTM-10, GE14 Provides a computer program for analyzing Volume 1, Supplements 2, 3, and 4, BWR system transients.

COTRANSA2: A Computer Program for Boiling Water Reactor Transient Analyses.

ANF-1358(P)(A) Revision 3, The Loss of 3.2.2 / ATRTUMTM-10, GE14 Presents a generic methodology for evaluating Feedwater Heating Transient in Boiling the loss of feedwater heating event.

Water Reactors.

EMIF-2209(P)(A) Revision 2, SPCB Critical 3.2.2 / ATRIUMTM-10, GE14 Presents the critical power correlation for use Power Correlation.

with the ATRIUTMTM-10 and GE14 fuel designs.

BSEP 06-0 129 Page 4 of 4 Report Applicable LCO Justification EMIF-2245(P)(A) Revision 0, Application of 3.2.2 / GE14 Provides direct and indirect approaches to Siemens Power Corporation's Critical develop parameters necessary to appropriately Power Correlations to Co-Resident Fuel.

model co-resident fuel with an approved critical power correlation.

EME-2361(P)(A) Revision 0, EXEM 3.2.1 / ATRIUMTM-10 Describes an evaluation model methodology BWR-2000 ECCS Evaluation Model.

for licensing analyses of postulated LOCAs in jet pump BWRs. The methodology was developed to comply with 10 CER 50.46 and 10 CFR 50 Appendix K criteria.

EMF-2292(P)(A) Revision 0, 3.2.1 / ATRIUMTM-10 Provides measured cladding temperatures ATRIUMiTm-1O: Appendix K Spray Heat from spray heat transfer tests to justify the use Transfer Coefficients.

of Appendix K coefficients for ATRIUTMTM-l10fuel LOCA analyses.

EMF-CC-074(P)(A) Volume 4 Revision 0, 3.3. 1. 1 / ATRIUMNTM-10, GE14 Describes methodology for stability analysis BWR Stability Analysis - Assessment of with input from the MICROBIURN-B2 reactor STAIF with Input from MICROBURN-B2.

core simulator.

NEDO-32465-A, Reactor Stability Detect 3.3. 1. 1 / ATRIUMTM-10, GE14 Describes the bases for period-based detection and Suppress Solutions Licensing Basis algorithm setpoint for the OPRMs.

LMethodology for Reload Applications.

I_________________

I_____________I_____

BSEP 06-0 129 Page 1 of 2 GNE BWR Approved Topical Reports for Brunswick Units 1 and 2 Technical Specification COLR References Applicable LCO /Assembly Types COLR Specified Limit NEDE-24011 -P-A Applicability 3.2.1 / GE14 Average Planar Linear Heat Generation The NEDE-2401 1 -P-A APLHGR limits are applied to Rate (APLHGR) off-rated conditions using power-and flow-dependent factors, MAPFACP and MAPFACf.

NIEDE-24011I-P-A APLHGR limits are applied to the following Equipment Out-of-Service (EOOS) conditions:

S LO(TS53.4. 1)

" Turbine Bypass OGS (TS 3.'7.6) 3.2.2 /GE14 Minimum Critical Power Ratio (MCPR)

NEDE-24011I-P-A will not be applied to establish MCPR operating limits.

Operating Limit MCPR for rated and off-rated power and flow conditions and EOOS operation will be established for GE 14 fuel using ARE VA-approved methods identified in Enclosure 2.

3.2.3 / GE14 Linear Heat Generation Rate (LHGR)

NEDE-240 11-P-A will not be applied to establish off-rated or flow-dependent or HOOS corrections to LHGR limits.

BSEP 06-0 129 Page 2 of 2 Applicable LCO / Assembly Types COLR Specified Limit I-NF-DE-24011I-P-A Applicability 3.3.2. 1, Table 3.3.2. 1-1 IGE 14 Rod Block Monitor (RBM) setpoints N-EDE-2401 I-P-A will not be applied to establish RBM and applicable reactor thermal power setpoints and applicable reactor thermal power ranges.

ranges The RBM setpoints and applicable thermal power ranges will be established using the ARE VA approved methods identified in Enclosure 2.

3.3. 1. 1, Table 3.3. 1. 1-1 IGE 14 Oscillation Power Range Monitor NTEDE-24011-P-A will not be applied to establish the (OPRM) period-based detection OPRMI setpoints. The OPRM setpoints will be algorithm (PBDA) setpoint limits established using ARE VA NP approved methods identified in Enclosure 2.

BSEP 06-0 129 Markup of Technical Specification Pages - Unit I

Definitions 1.1 1.1 Definitions LEAKAGE (continued)

b.

Unidentified LEAKAGE All LEAKAGE into the drywell that is not identified LEAKAGE;

c.

Total LEAKAGE Sum of the identified and unidentified LEAKAGE; and

d.

Pressure Boundary LEAKAGE LEAKAGE through a nonisolable fault in a Reactor Coolant System (RCS) component body, pipe wall, or L vessel wall.

LOGIC SYSTEM FUNCTIONAL TEST MINIMUM CRITICAL POWER RATIO (MCPR)

MODE A LOGIC SYSTEM FUNCTIONAL TEST shall be a test of all required logic components (i.e., all required relays and contacts, trip units, solid state logic elements, etc.) of a logic circuit, from as close to the sensor as practicable up to, but not including, the actuated device, to verify OPERABILITY.

The LOGIC SYSTEM FUNCTIONAL TEST may be performed by means of any series of sequential, overlapping, or total system steps so that the entire logic system is tested.

The MCPR shall be the smallest critical power ratio (CPR) that exists in the core. The CPR is that power in the assembly that is calculated by application of the appropriate correlation(s) to cause some point in the assembly to experience boiling transition, divided by the actual assembly operating power.

A MODE shall correspond to any one inclusive combination of mode switch position, average reactor coolant temperature, and reactor vessel head closure bolt tensioning specified in Table 1. 1-1 with fuel in the reactor vessel.

(continued)

Amendment No.

e Brunswick Unit 1114 1.1-4

INSERT 1.1 DEFINITIONS LINEAR HEAT GENERATION RATE (LHGR)

The LHGR shall be the heat generation rate per unit length of fuel rod. It is the integral of the heat flux over the heat transfer area associated with the unit length.

LHGR 3.2.3 3.2.3 LINEAR HEAT GENERATION RATE (LHGR)

LCO 3.2.3 APPLICABILITY:

All LHGRs shall be less than or equal to the limits specified in the COLR.

THERMAL POWER Ž:23% RTP.

ACTIONS__

CONDITION REQUIRED ACTION COMPLETION TIME A.

Any LHGR not within A. 1 Restore LHGR(s) to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />

limits, within limits.

B.

Required Action and B.1 Reduce THERMAL 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> associated Completion POWER to < 23% RTP.

Time not met.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY S R 3.2. 1.1 Verify all LHGRs are less than or equal to the limits Once within specified in the COLR.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after

Ž!23% RTP AND 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter Brunswick Unit 132-AmnetNo 3.2-4 Amendment No.

Recirculation Loops Operating 3.4.1 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.1 Recirculation Loops Operating LCO 3.4.1 Two recirculation loops with matched recirculation pump speeds shall be in operation, OR One recirculation loop may be in operation provided the following limits are applied when the associated LCO is applicable:

GNERT-ý

a.

LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)," single loop operation limits specified in the COLR; b.LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)," single1 loop operation limits specified in the COLR; (0 LCO 3.3.1.1, "Reactor Protection System (RPS) Instrumentation,"

Function 2.b (Average Power Range Monitors Simulated Thermal Power-High), Allowable Value of Table 3.3.1.1-1 is reset for single loop operation.

APPLICABILITY:

MODES 1 and 2.

ACTIONS_____________

CONDITION REQUIRED ACTION COMPLETION TIME A.

Requirements of the LCO A. 1 Satisfy the requirements of 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> not met.

the LCO.

(continued)

Brunswick Unit 1 3.4-1 BrunwickUni 1 34-1Amendment No.& I

INSERT LCQ 3.4.1 C.

LCO 3.2.3, "LINEAR HEAT GENERATION RATE (LHGR)," single ioop operation limits specified in the COLR; and

Main Turbine Bypass System 3.7.6 3.7 PLANT SYSTEMS 3.7.6 The Main Turbine Bypass System LCO 3.7.6 The Main Turbine Bypass System shall be OPERABLE.

OR The following limits are made applicable:

a.

LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)," limits for an inoperable Main Turbine Bypass System, as specified in the COLR;GZ an inoperable Main Turbine Bypass System, as specified in the APPLICABILITY:

THERMAL POWER Ž!23% RTP.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

Requirements of the LCO A. 1 Satisfy the requirements of 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> not met.

the LCO.

B.

Required Action and B. 1 Reduce THERMAL 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> associated Completion Time POWER to < 23% RTP.

not met.

Brunswick Unit 1 3.7-20 BrunwickUnit1 3.-20Amendment No.

g I

INSERT LCO 3.7.6

c. LCO 3.2.3, "LINEAR HEAT GENERATION RATE (LHGR)," limits for an inoperable Main Turbine Bypass System, as specified in the COLR.

Reporting Requirements 51.6 5.6 Reporting Requirements (continued) 5.6.5 CORE OPERATING LIMITS REPORT (COLR)

a.

Core operating limits shall be established prior to each reload cycle, or prior to any remaining portion of a reload cycle, and shall be documented in the COLR for the following:

1.

The AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR) for Specification 3.2.1;

2.

The MINIMUM CRITICAL POWER RATIO (MCPR) for Specification 3.2.2; The period based detection algorithm (PBDA) setpoint for

~y Function 2.f, Oscillation Power Range Monitor (OPRM) Upscale, for Specification 3.3.1.1; and.

The Allowable Values and power range setpoints for Rod Block

~

Monitor Upscale Functions for Specification 3.3.2.1.

b.

The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC, specifically those described in the following documents:

1.

NEDE-2401 1 -PA"General Electric Standard Application for Reactor Fuel" Ia;4st

ýa oedvsioný)

c.

The core operating limits shall be determined such that all applicable limits (e.g., fuel thermal mechanical limits, core thermal hydraulic limits, Emergency Core Cooling Systems (ECCS) limits, nuclear limits such as SDM, transient analysis limits, and accident analysis limits) of the safety analysis are met.

d.

The COLR, including any midcycle revisions or supplements, shall be provided upon issuance for each reload cycle to the NRC.

(continued)

Brunswick Unit 1 5.0-20 Amendment No.0

INSERT TS 5.6.5.a

3.

The LINEAR HEAT GENERATION RATE (LHGR) for Specification 3.2.3; INSERT TS 5.6.5.b

2.

XN-NF-81-58(P)(A), RODEX2 Fuel Rod Thermal-Mechanical Response Evaluation Model.

3.

XN-NF-85-67(P)(A), Generic Mechanical Design for Exxon Nuclear Jet Pump BWR Reload Fuel.

4.

EMF-85-74(P) Supplement 1(P)(A) and Supplement 2(P)(A),

RODEX2A (BWR) Fuel Rod Thermal-Mechanical Evaluation Model.

5.

ANF-89-98(P)(A), Generic Mechanical Design Criteria for BWR Fuel Designs.

6.

XN-NF-80-19(P)(A) Volume 1, Exxon Nuclear Methodology for Boiling Water Reactors - Neutronic Methods for Design and Analysis.

7.

XN-NF-80-19(P)(A) Volume 4, Exxon Nuclear Methodology for Boiling Water Reactors: Application of the ENG Methodology to BWR Reloads.

8.

EMF-2158(P)(A), Siemens Power Corporation Methodology for Boiling Water Reactors: Evaluation and Validation of CASMO-4/M ICROBU RN-B2.

9.

XN-NF-80-19(P)(A) Volume 3, Exxon Nuclear Methodology for Boiling Water Reactors, THERMEX: Thermal Limits Methodology Summary Description.

10.

XN-NF-84-1 05(P)(A) Volume 1, XCOBRA-T: A Computer Code for BWR Transient Thermal-Hydraulic Core Analysis.

11.

ANF-524(P)(A), ANF Critical Power Methodology for Boiling Water Reactors.

12.

ANF-91 3(P)(A) Volume 1, COTRANSA2: A Computer Program for Boiling Water Reactor Transient Analyses.

INSERT TS 5.6.5.b (Continued)

13.

ANF-1358(P)(A), The Loss of Feedwater Heating Transient in Boiling Water Reactors.

14.

EMF-2209(P)(A), SPCB Critical Power Correlation.

15.

EMF-2245(P)(A), Application of Siemens Power Corporation's Critical Power Correlations to Co-Resident Fuel.

16.

EMF-2361(P)(A), EXEM BWR-2000 ECCS Evaluation Model.

17.

EMF-2292(P)(A), ATRI UM TM-10: Appendix K Spray Heat Transfer Coefficients.

18.

EMF-CC-074(P)(A) Volume 4, BWR Stability Analysis:

Assessment of STAIF with Input from MICROBURN-B32.

19.

NEDO-32465-A, Reactor Stability Detect and Suppress Solutions Licensing Basis Methodology for Reload Applications.

BSEP 06-0 129 Typed Technical Specification Pages - Unit 1

Definitions 1.1 1.1 Definitions LEAKAGE (continued)

b.

Unidentified LEAKAGE LINEAR HEAT GENERATION RATE (LHGR)

LOGIC SYSTEM FUNCTIONAL TEST MINIMUM CRITICAL POWER RATIO (MCPR)

MODE All LEAKAGE into the drywell that is not identified LEAKAGE;

c.

Total LEAKAGE Sum of the identified and unidentified LEAKAGE; and

d.

Pressure Boundary LEAKAGE LEAKAGE through a nonisolable fault in a Reactor Coolant System (RCS) component body, pipe wall, or vessel wall.

The LHGR shall be the heat generation rate per unit length of fuel rod. It is the integral of the heat flux over the heat transfer area associated with the unit length.

A LOGIC SYSTEM FUNCTIONAL TEST shall be a test of all required logic components (i.e., all required relays and contacts, trip units, solid state logic elements, etc.) of a logic circuit, from as close to the sensor as practicable up to, but not including, the actuated device, to verify OPERABILITY.

The LOGIC SYSTEM FUNCTIONAL TEST may be performed by means of any series of sequential, overlapping, or total system steps so that the entire logic system is tested.

The MCPR shall be the smallest critical power ratio (CPR) that exists in the core. The CPR is that power in the assembly that is calculated by application of the appropriate correlation(s) to cause some point in the assembly to experience boiling transition, divided by the actual assembly operating power.

A MODE shall correspond to any one inclusive combination of mode switch position, average reactor coolant temperature, and reactor vessel head closure bolt tensioning specified in Table 1. 1-1 with fuel in the reactor vessel.

(continued)

Brunswick Unit 1 1.1-4 Bruswik Uit 1.-4Amendment No.

I

LHGR 3.2.3 3.2 POWER DISTRIBUTION LIMITS 3.2.3 LINEAR HEAT GENERATION RATE (LHGR)

LCO 3.2.3 APPLICABILITY:

All LHGRs shall be less than or equal to the limits specified in the COLR.

THERMAL POWER Ž!23% RTP.

ACTIONS_______

CONDITION REQUIRED ACTION COMPLETION TIME A.

Any LHGR not within A.1 Restore LHGR(s) to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />

limits, within limits.

B. Required Action and B. 1 Reduce THERMAL 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> associated Completion POWER to < 23% RTP.

Time not met.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.2.1.1 Verify all LHGRs are less than or equal to the limits Once within specified in the COLR.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after

Ž:23% RTP AND 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter Brunswick Unit 1 3.2-4 Bruswik Uit 3.-4Amendment No.

I

Recirculation Loops Operating 3.4.1 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.1 Recirculation Loops Operating LCO 3.4.1 Two recirculation loops with matched recirculation pump speeds shall be in operation, OR One recirculation loop may be in operation provided the following limits are applied when the associated LCO is applicable:

a.

LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)," single loop operation limits specified in the COLR;

b.

LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)," single loop operation limits specified in the COLR;

c.

LCO 3.2.3, "LINEAR HEAT GENERATION RATE (LHGR)," single loop operation limits specified in the COLR; and

d.

LCO 3.3.1.1, "Reactor Protection System (RPS) Instrumentation,"

Function 2.b (Average Power Range Monitors Simulated Thermal Power-High), Allowable Value of Table 3.3.1.1-1 is reset for single loop operation.

APPLICABILITY:

MODES 1 and 2.

ACTIONS__

CONDITION REQUIRED ACTION COMPLETION TIME A.

Requirements of the LCO A. 1 Satisfy the requirements of 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> not met.

the LCO.

(continued)

Brunswick Unit 1341AmnetNo 3.4-1 Amendment No.

I

Main Turbine Bypass System 3.7.6 3.7 PLANT SYSTEMS 3.7.6 The Main Turbine Bypass System LCO 3.7.6 The Main Turbine Bypass System shall be OPERABLE.

OR The following limits are made applicable:

a.

LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)," limits for an inoperable Main Turbine Bypass System, as specified in the COLR;

b.

LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)," limits for an inoperable Main Turbine Bypass System, as specified in the COLR; and

c.

LCO 3.2.3, "LINEAR HEAT GENERATION RATE (LHGR)," limits for an inoperable Main Turbine Bypass System, as specified in the COLR.

I APPLICABILITY:

THERMAL POWER Ž!23% RTP.

ACTIONS__

CONDITION REQUIRED ACTION COMPLETION TIME A.

Requirements of the LCO A. 1 Satisfy the requirements of 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> not met.

the LCO.

B. Required Action and B. 1 Reduce THERMAL 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> associated Completion Time POWER to < 23% RTP.

not met.

Brunswick Unit 1 3.7-20 Bruswik Uit 3.-20Amendment No.

I

Reporting Requirements 5.6 5.6 Reporting Requirements (continued) 5.6.5 CORE OPERATING LIMITS REPORT (COLR)

a.

Core operating limits shall be established prior to each reload cycle, or prior to any remaining portion of a reload cycle, and shall be documented in the COLR for the following:

1.

The AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR) for Specification 3.2. 1;

2.

The MINIMUM CRITICAL POWER RATIO (MCPR) for Specification 3.2.2;

3.

The LINEAR HEAT GENERATION RATE (LHGR) for Specification 3.2.3;

4.

The period based detection algorithm (PBDA) setpoint for Function 2.f, Oscillation Power Range Monitor (OPRM) Upscale, for Specification 3.3.1.1; and

5.

The Allowable Values and power range setpoints for Rod Block Monitor Upscale Functions for Specification 3.3.2.1.

b.

The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC, specifically those described in the following documents:

1.

NEDE-2401 1-P-A, "General Electric Standard Application for Reactor Fuel."

2.

XN-NF-8 1-58(P)(A), RODEX2 Fuel Rod Thermal-Mechanical Response Evaluation Model.

3.

XN-NF-85-67(P)(A), Generic Mechanical Design for Exxon Nuclear Jet Pump BWR Reload Fuel.

4.

EMF-85-74(P) Supplement 1(P)(A) and Supplement 2(P)(A),

RODEX2A (BWR) Fuel Rod Thermal-Mechanical Evaluation Model.

5.

ANF-89-98(P)(A), Generic Mechanical Design Criteria for BWR Fuel Designs.

(continued)

Brunswick Unit 1 5.0-20 Bruswik Uit 5.-20Amendment No.

I

Reporting Requirements 5.6 5.6 Reporting Requirements (continued) 5.6.5 CORE OPERATING LIMITS REPORT (COLR) (continued)

6.

XN-NF-80-1 9(P)(A) Volume 1, Exxon Nuclear Methodology for Boiling Water Reactors - Neutronic Methods for Design and Analysis.

7.

XN-NF-80-19(P)(A) Volume 4, Exxon Nuclear Methodology for Boiling Water Reactors: Application of the ENC Methodology to BWR Reloads.

8.

EMF-2158(P)(A), Siemens Power Corporation Methodology for Boiling Water Reactors: Evaluation and Validation of CASMO-4/MICROBURN-B32.

9.

XN-NF-80-19(P)(A) Volume 3, Exxon Nuclear Methodology for Boiling Water Reactors, THERMEX: Thermal Limits Methodology Summary Description.

10.

XN-NF-84-105(P)(A) Volume 1, XCOBRA-T: A Computer Code for BWR Transient Thermal-Hydraulic Core Analysis.

11.

ANF-524(P)(A), ANF Critical Power Methodology for Boiling Water Reactors.

12.

ANF-913(P)(A) Volume 1, COTRANSA2: A Computer Program for Boiling Water Reactor Transient Analyses.

13.

ANF-1358(P)(A), The Loss of Feedwater Heating Transient in Boiling Water Reactors.

14.

EMF-2209(P)(A), SPCB Critical Power Correlation.

15.

EMF-2245(P)(A), Application of Siemens Power Corporation's Critical Power Correlations to Co-Resident Fuel.

16.

EMF-2361(P)(A), EXEM BWR-2000 ECCS Evaluation Model.

17.

EMF-2292(P)(A), ATRI UM TM -1 0: Appendix K Spray Heat Transfer Coefficients.

18.

EMF-CC-074(P)(A) Volume 4, BWR Stability Analysis -

Assessment of STAlE with Input from MICROBURN-B32.

19.

NEDO-32465-A, Reactor Stability Detect and Suppress Solutions Licensing Basis Methodology for Reload Applications.

(continued)

Brunswick Unit 1 5.0-21 Bruswik Uit 5.-21Amendment No.

I

Reporting Requirements 5.6 5.6 Reporting Requirements (continued) 5.6.5 CORE OPERATING LIMITS REPORT (COLR) (continued)

c.

The core operating limits shall be determined such that all applicable limits (e.g., fuel thermal mechanical limits, core thermal hydraulic limits, Emergency Core Cooling Systems (ECCS) limits, nuclear limits such as SIDM, transient analysis limits, and accident analysis limits) of the safety analysis are met.

d.

The COLR, including any midcycle revisions or supplements, shall be provided upon issuance for each reload cycle to the NRC.

5.6.6 Post Accident Monitoring (PAM) Instrumentation Report When a report is required by Condition B or F of LCO 3.3.3.1, "Post Accident Monitoring (PAM) Instrumentation," a report shall be submitted within the following 14 days. The report shall outline the preplanned alternate method of monitoring, the cause of the inoperability, and the plans and schedule for restoring the instrumentation channels of the Function to OPERABLE status.

Brunswick Unit 1 5.0-22 Bruswik Uit 5.-22Amendment No.

I

High Radiation Area 5.7 5.0 ADMINISTRATIVE CONTROLS 5.7 High Radiation Area As provided in paragraph 20.1601 (c) of 10 CIFR Part 20, the following controls shall be applied to high radiation areas in place of the, controls required by paragraph 20.1601 (a) and (b) of 10 CFR Part 20:

5.7.1 High Radiation Areas with Dose Rates not exceeding 1.0 rem/hour (at 30 centimeters from the radiation sources or from any surface Penetrated by the radiation)

a.

Each accessible entryway to such an area shall be barricaded and conspicuously posted as a high radiation area. Such barricades may be opened as necessary to permit entry or exit of personnel or equipment.

b.

Access to, and activities in, each such area shall be controlled by means of a Radiation Work Permit (RWP) or equivalent that includes specification of radiation dose rates in the immediate work area(s) and other appropriate radiation protection equipment and measures.

c.

Individuals qualified in radiation protection procedures and personnel continuously escorted by such individuals may be exempted from the requirement for an RWP or equivalent while performing their assigned duties provided that they are following plant radiation protection procedures for entry to, exit from, and work in such areas.

d.

Each individual or group entering such an area shall:

1.

Possess a radiation monitoring device that continuously displays radiation dose rates in the area ("radiation monitoring and indicating device"); or

2.

Possess a radiation monitoring device that continuously integrates the radiation dose rates in the area and alarms when the device's dose alarm setpoint is reached ("alarming dosimeter"), with an appropriate alarm setpoint; or

3.

Possess a radiation monitoring device that continuously transmits dose rate and cumulative dose information to a remote receiver monitored by radiation protection personnel responsible for controlling personnel radiation exposure within the area; or (continued)

Brunswick Unit 1 502 mnmn o

5.0-23 Amendment No.

I

High Radiation Area 5.7 5.7 High Radiation Area 5.7.1 Hicih Radiation Areas with Dose Rates not exceeding 1.0 rem/hour (at 30 centimeters from the radiation sources or from any surface penetrated by the radiation) (continued)

4.

Possess a self-reading dosimeter and be under the surveillance, as specified in the RWP or equivalent, by means of closed circuit television, of personnel qualified in radiation protection procedures, responsible for controlling personnel radiation exposure in the area; or

5.

Be under the surveillance, as specified in the RWP or equivalent, of an individual at the work site, qualified in radiation protection procedures, equipped with a radiation monitoring and indicating device who is responsible for controlling personnel radiation exposure within the area.

e.

Except for individuals qualified in radiation protection procedures, entry into such areas shall be made only after dose rates in the area have been established and entry personnel are knowledgeable of them.

5.7.2 High Radiation Areas with Dose Rates Greater than 1.0 rem/hour (at 30 centimeters from the radiation source or from any surface Penetrated by the radiation), but less than 500 rads/hour (at 1 meter from the radiation source or from any surface Penetrated by the radiation)

a.

Each accessible entryway to such an area shall be conspicuously posted as a high radiation area and shall be provided with a locked door, gate, or guard that prevents unauthorized entry, and in addition:

1.

All such door and gate keys shall be maintained under the administrative control of the shift superintendent or the radiation control supervisor or designated representative; and

2.

Doors and gates shall remain locked or guarded except during periods of personnel or equipment entry or exit.

(continued)

Brunswick Unit 1 5.0-24 Bruswik Uit 5.-24Amendment No.

I

High Radiation Area 5.7 5.7 High Radiation Area 5.7.2 High Radiation Areas with Dose Rates Greater than 1.0 rem/hour (at 30 centimeters from the radiation source or from any surface penetrated by the radiation), but less than 500 rads/hour (at 1 meter from the radiation source or from any surface penetrated by the radiation) (continued)

b.

Access to, and activities in, each such area shall be controlled by means of an RWP or equivalent that includes specification of radiation dose rates in the immediate work area(s) and other appropriate radiation protection equipment and measures.

c.

Individuals qualified in radiation protection procedures may be exempted from the requirement for an RWP or equivalent while performing radiation surveys in such areas provided that they are following plant radiation protection procedures for entry to, exit from, and work in such areas.

d.

Each individual or group entering such an area shall:

1.

Possess an alarming dosimeter with an appropriate alarm setpoint; or

2.

Possess a radiation monitoring device that continuously transmits dose rate and cumulative dose information to a remote receiver monitored by radiation protection personnel responsible for controlling personnel radiation exposure within the area with the means to communicate with and control every individual in the area; or

3.

Possess a direct-reading dosimeter and be under the surveillance, as specified in the RWP or equivalent, by means of closed circuit television, of personnel qualified in radiation protection procedures, responsible for controlling personnel radiation exposure in the area, and with the means to communicate with and control every individual in the area; or

4.

Be under the surveillance, as specified in the RWP or equivalent, of an individual qualified in radiation protection procedures, equipped with a radiation monitoring and indicating device who is responsible for controlling personnel exposure within the area; or (continued)

Brunswick Unit 1 5.0-25 Bruswik Uit 5.-25Amendment No.

I

High Radiation Area 5.7 5.7 High Radiation Area 5.7.2 High Radiation Areas with Dose Rates Greater than 1.0 rem/hour (at 30 centimeters from the radiation source or from any surface Penetrated by the radiation), but less than 500 rads/hour (at 1 meter from the radiation source or from any surface penetrated by the radiation) (continued)

5.

Possess a radiation monitoring and indicating device in those cases where the options of Specifications 5.7.2.d.2, 5.7.2.d.3, and 5.7.2.d.4. above, are impractical or determined to be inconsistent with the "As Low As is Reasonably Achievable" principle.

e.

Except for individuals qualified in radiation protection procedures, entry into such areas shall be made only after dose rates in the area have been established and entry personnel are knowledgeable of them.

f.

Such individual areas that are within a larger area that is controlled as a high radiation area, where no enclosure exists for purpose of locking and where no enclosure can reasonably be constructed around the individual area need not be controlled by a locked door or gate, but shall be barricaded and conspicuously posted as a high radiation area, and a conspicuous, clearly visible flashing light shall be activated at the area as a warning device.

Brunswick Unit 1 502 mnmn o

5.0-26 Amendment No.

I

BSEP 06-0 129 Typed Technical Specification Pages - Unit 2

Definitions 1.1 1.1 Definitions LEAKAGE (continued)

b.

Unidentified LEAKAGE All LEAKAGE into the drywell that is not identified LEAKAGE;

c.

Total LEAKAGE Sum of the identified and unidentified LEAKAGE; and

d.

Pressure Boundary LEAKAGE LINEAR HEAT GENERATION RATE (LHGR)

LOGIC SYSTEM FUNCTIONAL TEST MINIMUM CRITICAL POWER RATIO (MCPR)

MODE LEAKAGE through a nonisolable fault in a Reactor Coolant System (RCS) component body, pipe wall, or vessel wall.

The LHGR shall be the heat generation rate per unit length of fuel rod. It is the integral of the heat flux over the heat transfer area associated with the unit length.

A LOGIC SYSTEM FUNCTIONAL TEST shall be a test of all required logic components (i.e., all required relays and contacts, trip units, solid state logic elements, etc.) of a logic circuit, from as close to the sensor as practicable up to, but not including, the actuated device, to verify OPERABILITY.

The LOGIC SYSTEM FUNCTIONAL TEST may be performed by means of any series of sequential, overlapping, or total system steps so that the entire logic system is tested.

The MCPR shall be the smallest critical power ratio (CPR) that exists in the core. The CPR is that power in the assembly that is calculated by application of the appropriate correlation(s) to cause some point in the assembly to experience boiling transition, divided by the actual assembly operating power.

A MODE shall correspond to any one inclusive combination of mode switch position, average reactor coolant temperature, and reactor vessel head closure bolt tensioning specified in Table 1. 1-1 with fuel in the reactor vessel.

(continued)

Brunswick Unit 2 1.1-4 Bruswik Uit 1.-4Amendment No.

I

LHGR 3.2.3 3.2 POWER DISTRIBUTION LIMITS 3.2.3 LINEAR HEAT GENERATION RATE (LHGR)

LCO 3.2.3 APPLICABILITY:

All LHGRs shall be less than or equal to the limits specified in the COLR.

THERMAL POWER Ž!23% RTP.

ACTIONS_______

CONDITION REQUIRED ACTION COMPLETION TIME A.

Any LHGR not within A.1 Restore LHGR(s) to 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />

limits, within limits.

B. Required Action and B.1 Reduce THERMAL 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> associated Completion POWER to < 23% RTP.

Time not met.

SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.2. 1.1 Verify all LHGRs are less than or equal to the limits Once within specified in the COLR.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after

Ž!23% RTP AND 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter Brunswick Unit 2 3.2-4

~ruswik Uit 3.-4Amendment No.

I

Recirculation Loops Operating 3.4.1 3.4 REACTOR COOLANT SYSTEM (RCS) 3.4.1 Recirculation Loops Operating LCO 3.4.1 Two recirculation loops with matched recirculation pump speeds shall be in operation, OR One recirculation loop may be in operation provided the following limits are applied when the associated LCO is applicable:

a.

LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)," single loop operation limits specified in the COLR;

b.

LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)," single loop operation limits specified in the COLR;

c.

LCO 3.2.3, "LINEAR HEAT GENERATION RATE (LHGR)," single loop operation limits specified in the COLR; and

d.

LCO 3.3.1.1, "Reactor Protection System (RPS) Instrumentation,"

Function 2.b (Average Power Range Monitors Simulated Thermal Power-High), Allowable Value of Table 3.3.1.1-1 is reset for single loop operation.

APPLICABILITY:

MODES 1 and 2.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

Requirements of the LCO A. 1 Satisfy the requirements of 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> not met.

the LCO.

(continued)

Brunswick Unit 234-AmnetNo 3.4-1 Amendment No.

I

Main Turbine Bypass System 3.7.6 3.7 PLANT SYSTEMS 3.7.6 The Main Turbine Bypass System LCO 3.7.6 The Main Turbine Bypass System shall be OPERABLE.

OR The following limits are made applicable:

a.

LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)," limits for an inoperable Main Turbine Bypass System, as specified in the COLR; I

b.

LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)," limits for an inoperable Main Turbine Bypass System, as specified in the COLR; and

c.

LCO 3.2.3, "LINEAR HEAT GENERATION RATE (LHGR)," limits for an inoperable Main Turbine Bypass System, as specified in the COLR.

APPLICABILITY:

THERMAL POWER Ž!23% RTP.

ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.

Requirements of the LCO A. 1 Satisfy the requirements of 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> not met.

the LCO.

B.

Required Action and B. 1 Reduce THERMAL 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> associated Completion Time POWER to < 23% RTP.

not met.

Brunswick Unit 2 372 mnmn o

3.7-20 Amendment No.

I

Reporting Requirements 5.6 5.6 Reporting Requirements (continued) 5.6.5 CORE OPERATING LIMITS REPORT (COLR)

a.

Core operating limits shall be established prior to each reload cycle, or prior to any remaining portion of a reload cycle, and shall be documented in the COLR for the following:

1.

The AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR) for Specification 3.2.1;

2.

The MINIMUM CRITICAL POWER RATIO (MCPR) for Specification 3.2.2;

3.

The LINEAR HEAT GENERATION RATE (LHGR) for Specification 3.2.3;

4.

The period based detection algorithm (PBDA) setpoint for Function 2.f, Oscillation Power Range Monitor (OPRM) Upscale, for Specification 3.3. 1. 1; and

5.

The Allowable Values and power range setpoints for Rod Block Monitor Upscale Functions for Specification 3.3.2.1.

b.

The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC, specifically those described in the following documents:

1.

NEDE-2401 1-P-A, "General Electric Standard Application for Reactor Fuel."

2.

XN-NF-8 1-58(P)(A), RODEX2 Fuel Rod Thermal-Mechanical Response Evaluation Model.

3.

XN-NF-85-67(P)(A), Generic Mechanical Design for Exxon Nuclear Jet Pump BWR Reload Fuel.

4.

EMF-85-74(P) Supplement 1 (P)(A) and Supplement 2(P)(A),

RODEX2A (BWR) Fuel Rod Thermal-Mechanical Evaluation Model.

5.

ANF-89-98(P)(A), Generic Mechanical Design Criteria for BWR Fuel Designs.

(continued)

Brunswick Unit 2 5.0-20 Bruswik Uit 5.-20Amendment No.

I

Reporting Requirements 5.6 5.6 Reporting Requirements (continued) 5.6.5 CORE OPERATING LIMITS REPORT (COLR) (continued)

6.

XN-NF-80-1 9(P)(A) Volume 1, Exxon Nuclear Methodology for Boiling Water Reactors - Neutronic Methods for Design and Analysis.

7.

XN-NF-80-1 9(P)(A) Volume 4, Exxon Nuclear Methodology for Boiling Water Reactors: Application of the ENC Methodology to BWR Reloads.

8.

EMF-2158(P)(A), Siemens Power Corporation Methodology for Boiling Water Reactors: Evaluation and Validation of CASMO-4/MICROBURN-B2.

9.

XN-NF-80-19(P)(A) Volume 3, Exxon Nuclear Methodology for Boiling Water Reactors, THERMEX: Thermal Limits Methodology Summary Description.

10.

XN-NF-84-105(P)(A) Volume 1, XCOBRA-T: A Computer Code for BWR Transient Thermal-Hydraulic Core Analysis.

11.

ANF-524(P)(A), ANF Critical Power Methodology for Boiling Water Reactors.

12.

ANF-913(P)(A) Volume 1, COTRANSA2: A Computer Program for Boiling Water Reactor Transient Analyses.

13.

ANF-1358(P)(A), The Loss of Feedwater Heating Transient in Boiling Water Reactors.

14.

EMF-2209(P)(A), SPCB Critical Power Correlation.

15.

EMF-2245(P)(A), Application of Siemens Power Corporation's Critical Power Correlations to Co-Resident Fuel.

16.

EMF-2361 (P)(A), EXEM BWR-2000 ECCS Evaluation Model.

17.

EMF-2292(P)(A), ATRI UM TM-1 0: Appendix K Spray Heat Transfer Coefficients.

18.

EMF-CC-074(P)(A) Volume 4, BWR Stability Analysis -

Assessment of STAIF with Input from MICROBURN-B32.

19.

NEDO-32465-A, Reactor Stability Detect and Suppress Solutions Licensing Basis Methodology for Reload Applications.

(continued)

Brunswick Unit 2 5.0-21 Bruswik Uit 5.-21Amendment No.

I

Reporting Requirements 5.6 5.6 Reporting Requirements (continued) 5.6.5 CORE OPERATING LIMITS REPORT (COLR) (continued)

c.

The core operating limits shall be determined such that all applicable limits (e.g., fuel thermal mechanical limits, core thermal hydraulic limits, Emergency Core Cooling Systems (ECCS) limits, nuclear limits such as SIDM, transient analysis limits, and accident analysis limits) of the safety analysis are met.

d.

The COLR, including any midcycle revisions or supplements, shall be provided upon issuance for each reload cycle to the NRC.

5.6.6 Post Accident Monitoring (PAM) Instrumentation Report When a report is required by Condition B or F of LCO 3.3.3.1, "Post Accident Monitoring (PAM) Instrumentation," a report shall be submitted within the following 14 days. The report shall outline the preplanned alternate method of monitoring, the cause of the inoperability, and the plans and schedule for restoring the instrumentation channels of the Function to OPERABLE status.

Brunswick Unit 2 5.0-22 Bruswik Uit 5.-22Amendment No.

I

High Radiation Area 5.7 5.0 ADMINISTRATIVE CONTROLS 5.7 High Radiation Area As provided in paragraph 20.1601 (c) of 10 CFR Part 20, the following controls shall be applied to high radiation areas in place of the controls required by paragraph 20.1601 (a) and (b) of 10 CFR Part 20:

5.7.1 High Radiation Areas with Dose Rates not exceeding 1.0 rem/hour (at 30 centimeters from the radiation sources or from any surface Penetrated by the radiation)

a.

Each accessible entryway to such an area shall be barricaded and conspicuously posted as a high radiation area. Such barricades may be opened as necessary to permit entry or exit of personnel or equipment.

b.

Access to, and activities in, each such area shall be controlled by means of a Radiation Work Permit (RWP) or equivalent that includes specification of radiation dose rates in the immediate work area(s) and other appropriate radiation protection equipment and measures.

c.

Individuals qualified in radiation protection procedures and personnel continuously escorted by such individuals may be exempted from the requirement for an RWP or equivalent while performing their assigned duties provided that they are following plant radiation protection procedures for entry to, exit from, and work in such areas.

d.

Each individual or group entering such an area shall:

1.

Possess a radiation monitoring device that continuously displays radiation dose rates in the area ("radiation monitoeing and indicating device"); or

2.

Possess a radiation monitoring device that continuously integrates the radiation dose rates in the area and alarms when the device's dose alarm setpoint is reached ("alarming dosimeter"), with an appropriate alarm setpoint; or

3.

Possess a radiation monitoring device that continuously transmits dose rate and cumulative dose information to a remote receiver monitored by radiation protection personnel responsible for controlling personnel radiation exposure within the area; or (continued)

Brunswick Unit 2 5.0-23 Bruswik Uit 5.-23Amendment No.

I

High Radiation Area 5.7 5.7 High Radiation Area 5.7.1 Higih Radiation Areas with Dose Rates not exceeding 1.0 rem/hour (at 30 centimeters from the radiation sources or from any surface penetrated by the radiation) (continued)

4.

Possess a self-reading dosimeter and be under the surveillance, as specified in the RWP or equivalent, by means of closed circuit television, of personnel qualified in radiation protection procedures, responsible for controlling personnel radiation exposure in the area; or

5.

Be under the surveillance, as specified in the RWP or equivalent, of an individual at the work site, qualified in radiation protection procedures, equipped with a radiation monitoring and indicating device who is responsible for controlling personnel radiation exposure within the area.

e.

Except for individuals qualified in radiation protection procedures, entry into such areas shall be made only after dose rates in the area have been established and entry personnel are knowledgeable of them.

5.7.2 Hi-gh Radiation Areas with Dose Rates Greater than 1.0 rem/hour (at 30 centimeters from the radiation source or from any surface Penetrated by the radiation), but less than 500 rads/hour (at 1 meter from the radiation source or from any surface Penetrated by the radiation)

a.

Each accessible entryway to such an area shall be conspicuously posted as a high radiation area and shall be provided with a locked door, gate, or guard that prevents unauthorized entry, and in addition:

1.

All such door and gate keys shall be maintained under the administrative control of the shift superintendent or the radiation control supervisor or designated representative; and

2.

Doors and gates shall remain locked or guarded except during periods of personnel or equipment entry or exit.

(continued)

Brunswick Unit 2 502 mnmn o

5.0-24 Amendment No.

I

High Radiation Area 5.7 5.7 High Radiation Area 5.7.2 High Radiation Areas with Dose Rates Greater than 1.0 rem/hour (at 30 centimeters from the radiation source or from any surface Penetrated by the radiation), but less than 500 rads/hour (at 1 meter from the radiation source or from any surface penetrated by the radiation) (continued)

b.

Access to, and activities in, each such area shall be controlled by means of an RWP or equivalent that includes specification of radiation dose rates in the immediate work area(s) and other appropriate radiation protection equipment and measures.

c.

Individuals qualified in radiation protection procedures may be exempted from the requirement for an RWP or equivalent while performing radiation surveys in such areas provided that they are following plant radiation protection procedures for entry to, exit from, and work in such areas.

d.

Each individual or group entering such an area shall:

1.

Possess an alarming dosimeter with an appropriate alarm setpoint; or

2.

Possess a radiation monitoring device that continuously transmits dose rate and cumulative dose information to a remote receiver monitored by radiation protection personnel responsible for controlling personnel radiation exposure within the area with the means to communicate with and control every individual in the area; or

3.

Possess a direct-reading dosimeter and be under the surveillance, as specified in the RWP or equivalent, by means of closed circuit television, of personnel qualified in radiation protection procedures, responsible for controlling personnel radiation exposure in the area, and with the means to communicate with and control every individual in the area; or

4.

Be under the surveillance, as specified in the RWP or equivalent, of an individual qualified in radiation protection procedures, equipped with a radiation monitoring and indicating device who is responsible for controlling personnel exposure within the area, or (continued)

Brunswick Unit 2 502 mnmn o

5.0-25 Amendment No.

I

High Radiation Area 5.7 5.7 High Radiation Area 5.7.2 Hi-gh Radiation Areas with Dose Rates Greater than 1.0 rem/hour (at 30 centimeters from the radiation source or from any surface penetrated by the radiation), but less than 500 rads/hour (at 1 meter from the radiation source or from any surface Penetrated by the radiation) (continued)

5.

Possess a radiation monitoring and indicating device in those cases where the options of Specifications 5.7.2.d.2, 5.7.2.d.3, and 5.7.2.d.4, above, are impractical or determined to be inconsistent with the "As Low As is Reasonably Achievable" principle.

e.

Except for individuals qualified in radiation protection procedures, entry into such areas shall be made only after dose rates in the area have been established and entry personnel are knowledgeable of them.

f.

Such individual areas that are within a larger area that is controlled as a high radiation area, where no enclosure exists for purpose of locking and where no enclosure can reasonably be constructed around the individual area need not be controlled by a locked door or gate, but shall be barricaded and conspicuously posted as a high radiation area, and a conspicuous, clearly visible flashing light shall be activated at the area as a warning device.

Brunswick Unit 2 502 mnmn o

5.0-26 Amendment No.

I

BSEP 06-0 129 Marked-up Technical Specification Bases Pages - Unit I (For In formation Only)

TABLE OF CONTENTS B 2.0 SAFETY LIMITS (SLs)...........................................................

B 2. 1.1 -1 B 2.1.1 Reactor Gore SLs............................................................

B 2. 1.1 -1 B 2.1.2 Reactor Coolant System (RCS) Pressure SL.............................

B 2.1.2-1 B 3.0 LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITY........

B 3.0-1 B 3.0 SURVEILLANCE REQUIREMENT (SR) APPLICABILITY.................... B 3.0-11 B 3.1 REACTIVITY CONTROL SYSTEMS........................................... B 3. 1.1 -1 B 3.1.1 SHUTDOWN MARGIN (8DM)..............................................

B 3. 1.1 -1 B 3.1.2 Reactivity Anomalies.........................................................

B 3.1.2-1 B 3.1.3 Control Rod OPERABILITY......

B 3.1.3-1 B 3.1.ý4 Control Rod Scram Times...................................................

B 3.1.4-1 B 3.1.5 Control Rod Scram Accumulators.......................................... B 3.1.5-1 B 3.1.6 Rod Pattern Control..........................................................

B 3.1.6-1 B 3.1.7 Standby Liquid Control (SLC) System.....................................

B 3.1.7-1 B 3.1.8 Scram Discharge Volume (SDV) Vent and Drain Valves................. B 3.1.8-1 B 3.2 POWER DISTRIBUTION LIMITS..................................

B 3.2.1 -1 B 3.2.1 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR).................................................................

B 3.2. 1-1 B 3.2.2 MINIMUM CRITICAL POWER RATIO (MCPR)...........................

B 3.2.2-1 B 3.3 INSTRUMENTATION............................................................

B 3.3. 1. 1-1 B 3.3. 1.1 Reactor Protection System (RPS) Instrumentation.......................

B 3.3. 1. 1-1 B 3.3.1.2 Source Range Monitor (SRM) Instrumentation............................ B 3.3.1.2-1 B 3.3.2.1 Control Rod Block Instrumentatibn.........................................

B 3.3.2.1 -1 B 3.3.2.2 Feedwater and Main Turbine High Water Level Trip Instrumentation..........................................................

B 3.3.2.2-1 B 3.3.3.1 Post Accident Monitoring (PAM) Instrumentation......................... B 3.3.3.1 -1 B 3.3.3.2 Remote Shutdown Monitoring Instrumentation............................ B 3.3.3.2-1 B 3.3.4.1 Anticipated Transient Without Scram Recirculation Pump Trip (ATWS-RPT) Instrumentation........................................... B 3.3.4.1 -1 B 3.3.5.1 Emergency Core Cooling System (EGGS) Instrumentation.............. B 3.3.5.1 -1 B 3.3.5.2 Reactor Gore Isolation Cooling (ROIC) System Instrumentation........ B 3.3.5.2-1 B 3.3.6.1 Primary Containment Isolation Instrumentation...........................

B 3.3.6. 1-1 B 3.3.6.2 Secondary Containment Isolation Instrumentation.......................

B 3.3.6.2-1 B 3.3.7.1 Control Room Emergency Ventilation (CREV) System Instrumentation..........................................................

B 3.3.7.1 -1 (continued)

LNE-A~R IAEAT-Gv4EPrTiom RATE (LNG)----.

.23 Brunswick Unit 1 Brunwic Unt 1Revision No.(R

Reactor Core SLs B 2.1.1 BASES BACKGROUND (continued)

Operation above the boundary of the nucleate boiling regime could result in excessive cladding temperature because of the onset of transition boiling and the resultant sharp reduction in heat transfer coefficient.

Inside the steam film, high cladding temperatures are reached, and a cladding water (zirconium water) reaction may take place. This chemical reaction results in oxidation of the fuel cladding to a structurally weaker form. This weaker form may lose its integrity, resulting in an uncontrolled release of activity to the reactor coolant.

The reactor vessel water level SL ensures that adequate core cooling capability is maintained during all MODES of reactor operation.

Establishment of Emergency Core Cooling System initiation setpoints higher than this safety limit provides margin to ensure the safety limit will not be reached or exceeded such that fuel damage would occur.

APPLICABLE SAFETY ANALYSES The fuel cladding must not sustain damage as a result of normal.

operation and AO0s. The reactor core SLs are established to preclude violation of the fuel design criterion that an MCPR limit is to be established, such that at least 99.9% of the fuel rods in the core would not be expected to experience the onset of transition boiling.

The Reactor Protection System setpoints (LCO 3.3.1.1, "Reactor Protection System (RPS) Instrumentation'), in combination with the other LCOs, are designed to prevent any anticipated combination of transient conditions for Reactor Coolant System water level, pressure, and THERMAL POWER level that would result in reaching the MCPR limit.

2.1.1.1 Fuel Cladding Integrity INSPITcritical po r correlatio are appli le for all cri i al power

-P4SR calculation at pressure -785 psi d core flow - 10% of rate ow.

For operation at low pressures or low flows, another basis is used, as follows:

Since the pressure drop in the bypass region is essentially all elevation head, the core pressure drop at low power and flows will always be > 4.5 psi. Analyses show that with a bundle flow of 28 x 10 lb/hr, bundle pressure drop is nearly independent of bundle power and has a value of 3.5 psi. Thus, the bundle flow (continued)

Brunswick Unit 1 B 2.1.1-2 Brunwic Uni 1

2.11-2Revision No.0

INSERT TO B 2.1.1.1 (Fuel Cladding Integrity) APPLICABLE SAFETY ANALYSIS The SPCB critical power correlation is valid for critical power calculations at pressures Ž: 571.4 psia and bundle mass fluxes *Žý 0.087E+6 Ibm/hr-ft2 (Reference 1).

Reactor Core SLs B 2. 1.1 BASES APPLICABLE 2.1.1.1 Fuel Cladding Integrity (continued)

SAFET ANAYSESwith a 4.5 psi driving head will be > 28 x 103 lb/hr. Full scale ATLAS test data taken at pressures from 14.7 psia (0 psig) to 800 psia (785 psig) indicate that the fuel assembly critical power at this flow is approximately 3.35 MWt. With the design peaking factors, this corresponds to a THERMAL POWER > 46% RTP.

Thus, a THERMAL POWER limit of 23% RTP for reactor pressure

< 785 psig is conservative.

2.1.1.2 MCPR The fuel cladding integrity SL is set such that no fuel damage is calculated to occur if the limit is not violated. Since the parameters that result in fuel damage are not directly observable during reactor operation, the thermal and hydraulic conditions that result in the onset of transition boiling have been used to mark the beginning of the region in which fuel damage could occur. Although it is recognized that the onset of transition boiling would not result in damage to BWR fuel rods, the critical power at which boiling transition is calculated to occur has been adopted as a convenient limit. However, the uncertainties in monitoring the core operating state and in the procedures used to calculate the critical power result in an uncertainty in the value of the critical power. Therefore, the fuel cladding integrity SL is defined as the critical power ratio in the limiting fuel assembly for which more than 99.9% of the fuel rods in the core are expected to avoid boiling transition, considering the power distribution within the core and all uncertainties.

The MCPR SL is determined using a statistical model that combines all the uncertainties in operating parameters and the procedures used to calculate critical power. The probability of the occurrence of boiling Strabsation of dthertaeduintisedi the tprve ermnationecofie MCPR SL ae~reg rn ReS ee I

efr 1,

2.so ari 3lds bycrb refh c

ceracea-Brunswic Uni 1f Bh 2.11-Revsio N.

usiIS

Reactor Core SLs B 2.1.1 BASES APPLICABLE SAFETY ANALYSES (continued) 2.1.1.3 Reactor Vessel Water Level During MODES 1 and 2 the reactor vessel water level is required to be above the top of the active irradiated fuel, to provide core cooling capability. In conjunction with LCOs, the limiting safety system settings, defined in LCO 3.3.1.1 as the Allowable Values, establish the threshold for protective system action to prevent exceeding acceptable limits, including this reactor vessel water level SL, during Design Basis Accidents. With fuel in the reactor vessel during periods when the reactor is shut down, consideration must be given to water level requirements due to the effect of decay heat. If the water level should drop below the top of the active irradiated fuel during this period, the ability to remove decay heat is reduced. This reduction in cooling capability could lead to elevated cladding temperatures and clad perforation in the event that the water level becomes < 2/3 of the core height. The reactor vessel water level SL has been established at the top of the active irradiated fuel to provide a point that can be monitored and to also provide adequate margin for effective action.

SAFETY LIMITS The reactor core SLs are established to protect the integrity of the fuel clad barrier to prevent the release of radioactive materials to the environs.

SL 2. 1. 1.1 and SL 2.1.1.2 ensure that the core operates within the fuel design criteria. SL 2.1.1.3 ensures that the reactor vessel water level is greater than the top of the active irradiated fuel in order to prevent elevated clad temperatures and resultant clad perforations.

APPLICABILITY SLs 2.1.1.1, 2.1.1.2, and 2.1.1.3 are applicable in all MODES.

SAFETY LIMIT Exceeding an SL may cause fuel damage and create a potential VIOLATIONS for radioactive releases in excess of 10 CFR 50.67, "Accident Source Term," limits_ (Ref~. Therefore, it is required to insert all insertable contol odsand restore compliance with the SLs within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />. The (continued)

Brunswick Unit 1 B 2.1.1-4 Brunwic Uni 1 2.11-4Revision No.0 I

Reactor Core SLs B 2.1.1 BASES SAFETY LIMIT 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> Completion Time ensures that the operators take prompt remedial VIOLATIONS action and also ensures that the probability of an accident occurring (continued) during this period is minimal.

~

10 CFR 50.67.

2. EMF-224S(P')(A\\, I'Apf hca~oA-cV Giemeris 'Pow'er-Qorror-aý,on s Crl-k-coa 'Power, Qorr-etaHcans +0a Clo-Rescl~en+ FLA~el

(

idenfitLFie8 in +he COLR).

3. AWNF-S24 (P)(A),"ANP Cri4-ccd PoL-er Meý4odolo~cy -Fcr 3oi~n~ kc~ecRecxci-ors," (,as itcerni-t4~ed in +h-e CoLR).

Brunswick Unit 1 B 2.1.1-5 Revision NoA. I

Control Rod OPERABILITY B 3.1.3 BASES APPLICABLE SAFETY ANALYSES (continued)

The capability to insert the control rods provides assurance that the assumptions for scram reactivity in the DRA and transient analyses are not violated. Since the SDM ensures the reactor will be subcritical with the highest worth control rod withdrawn (assumed single failure), the additional failure of a second control rod to insert, if required, could invalidate the demonstrated 5DM and potentially limit the ability of the CR0D System to hold the reactor subcritical. If the control rod is stuck at an inserted position and becomes dlecoupled from the CRID, a control rod drop accident (ORDA) can possibly occur. Therefore, the requirement that all control rods be OPERABLE ensures the CR0D System can perform its intended function.

The control rods also protect the fuel from damage which could result in release of radioactivity. The limits protected are the MCPR Safety Limit (SL) (see Bases for SL 2. 1. 1, "Reactor Core SLs," and LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)"), the 1% cladding plastic strain fuel design limit (see Bases for LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)j), and the fuel damage limit (see Bases for LCO 3.1.6, "Rod Pattern Control") during reactivity insertion events.

The negative reactivity insertion (scram) provided by the CR0D System provides the analytical basis for determination of plant thermal lim 'its and provides protection against fuel damage limits during a CRIDA. The Bases for LCO 3.1.4, LCO 3.1.5, and LCO 3.1.6 discuss in more detail how the SLs are protected by the CRID System.

Control rod OPERABILITY satisfies Criterion 3 of 10 CFR 50.36(c)(2)(ii)

(Ref. 5).

LCO The OPERABILITY of an individual control rod is based on a combination of factors, primarily, the scram insertion times, the control rod coupling integrity, and the ability to determine the control rod position.

Accumulator OPERABILITY is addressed by LCO 3.1.5. The associated scram accumulator status for a control rod only affects the scram insertion times; therefore, an inoperable accumulator does not immediately require declaring a control rod inoperable. Although not all control rods are required to be OPERABLE to satisfy the intended (continued)

Brunwic Unt 1B 3.1.3-2 Revision No.0 Brunswick Unit 1

Control Rod Scram Times B 3.1.4 BASES APPLICABLE SAFETY ANALYSES (continued)

The scram function of the CRID System protects the MCPR Safety Limit (SL) (see Bases for SL 2.1.1, "Reactor Core SLs," and LCO 3.2,2, "MINIMUM CRITICAL POWER RATIO (MCPR)") and the 1% cladding plastic strain fuel design limit (see Bases for LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGRJ, which ensure that no fuel damage will occur if these limits are not exceeded.

Above 800 psig, the scram function is designed to insert negative reactivity at a rate fast enough to prevent the actual MCPR from becoming less than the MCPR SL, during the analyzed limiting power transient. Below 800 psig, the scram function is assumed to perform during the control rod drop accident (Ref. 5) and, therefore, also provides protection against violating fuel damage limits during reactivity insertion accidents (see Bases for LCO 3.1.6, "Rod Pattern Control"). For the reactor vessel overpressure protection analysis, the scram function, along with the safety/relief valves, ensure that the peak vessel pressure is maintained within the applicable ASME Code limits.

Control rod scram times satisfy Criterion 3 of 10 GFR 50.36(c)(2)(ii)

(Ref. 6).

LCO The scram times specified in Table 3.1.4-1 (in the accompanying LCO) are required to ensure that the scram reactivity assumed in the DBA and transient analysis is met (Ref. 5).

To account for single failures and "slow" scramming control rods, the scram times specified in Table 3.1.4-1 are faster than those assumed in the design basis analysis. The scram times have a margin that allows up to approximately 7% of the control rods (e.g., 137 x 7% :z10) to have scram times exceeding the specified limits (i.e., "slow" control rods) assuming a single stuck control rod (as allowed by LCO 3.1.3, "Control Rod OPERABILITY") and an additional control rod failing to scram per the single failure criterion. The scram times are specified as a function of reactor steam dome pressure to account for the pressure dependence of the scram times. The scram times are specified relative to measurements based on reed switch positions, which provide the control rod position indication. The reed switch closes ("pickup") when the index tube passes a specific location and then opens ("dropout") as the index tube travels upward. Verification of the specified scram times in (continued)i ar,8 LCO 3. 2.3, " L1NE#M HNET GEP4ERAriopt4 RATEi (LI4GR)"

B 3.1.4-2 Revision No.0 Brunswick Unit 1

Control Rod Scram Accumulators B 3.1.5 B 3.1 REACTIVITY CONTROL SYSTEMS B 3.1.5 Control Rod Scram Accumulators BASES BACKGROUND The control rod scram accumulators are part of the Control Rod Drive (CRD) System and are provided to ensure that the control rods scram under varying reactor conditions. The control rod scram accumulators store sufficient energy to fully insert a control rod independent of any other source of energy. The accumulator is a hydraulic cylinder with a free floating piston. The piston separates the water used to scram the control rods from the nitrogen, which provides the required energy. The scram accumulators are necessary to scram the control rods within the required insertion times of LCO 3.1.4, "Control Rod Scram Times."*

APPLICABLE The analytical methods and assumptions used in evaluating the control SAFETY ANALYSES rod scram function are presented in References 1, 2, and 3. The Design Basis Accident (DBA) and transient analyses. assume that all of the control rods scram at a specified insertion rate. OPERABILITY of each individual control rod scram accumulator, along with LCO 3.1.3, "Control Rod OPERABILITY," and LCO 3.1.4, ensures that the scram reactivity assumed in the DBA and transient analyses can be met. The existence of an inoperable accumulator may invalidate prior scram time measurements for the associated control rod.

The scram function of the CRD System, and therefore the OPERABILITY of the accumulators, protects the MCPR Safety Limit (see Bases for SL 2.1.1, "Reactor Core SLs," and LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)") and 1% cladding plastic strain fuel design limit (see Bases for LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR) ), which ensure that no fuel damage will occur if these limits are not exceeded (see Bases for LCO 3.1.4). In addition, the scram function at low reactor vessel pressure (i.e., startup conditions) provides protection against violating fuel design limits during reactivity insertion accidents (see Bases for LCO 3.1.6, "Rod Pattern Control").

Control rod scram accumulators satisfy Criterion 3 of 10 CFR 50.36(c)(2)(ii) (Ref. 4).

(continued)

QnA LCO 3.2.3, "Li NEAT GEMERA-TION KA-TE (LHGiR t Brunswick Unit 1 B 3.1.5-1 Brunwic Uni 1 3.15-1Revision No. 0 1

Rod Pattern Control B83.1.6 B 3.1 REACTIVITY CONTROL SYSTEMS B 3.1.6 Rod Pattern Control BASES BACKGROUND Control rod patterns during startup conditions are controlled by the operator and the rod worth minimizer (RWM) (LCO 3.3.2.1, "Control Rod Block Instrumentation"), so that only specified control rod sequences and relative positions are allowed over the operating range of all control rods inserted to 8.75% RTP. The sequences limit the potential amount of reactivity addition that could occur in the event of a Control Rod Drop Accident (CRDA).

This Specification assures that the control rod patterns are consistent with the assumptions of the CRDA analyses of References 1, 2 and 3.

APPLICABLE The analytical methods and assumptions used in evaluating the CRDA SAFETY ANALYSES are summarized in References 2 and 3. ORDA analyses assume that the reactor operator follows prescribed withdrawal sequences. These sequences define the potential initial conditions for the ORDA analysis.

The RWM (LCO 3.3.2.1) provides backup to operator control of the withdrawal sequences to ensure that the initial conditions of the CRDA analysis are not violated.

Prevention or mitigation of positive reactivity insertion events is necessary to limit the energy deposition in the fuel, thereby preventing significant fuel damage which could result in the undue release of radioactivity.

S ince the failure consequences for U0 2 have shown that sudden fuel pin

/~..jruptur7e requires a fuel energy deposition of approximately 425 cal/gmn Y(Ref.(A, the fuel damage limit of 280 cal/gm, provides a margin of safety from significant core damage which would result in release of radioactivity (Rf.Generic evaluations (Refs.W 0"i) of a design basis CRDA aie.

CRDA resulting in a peak fuel energy deposition of 280 cal/gm) have shown that if the peak fuel enthalpy remains below 280 cal/gm, then the maximum reactor pressure will be less than the required ASME Code 9

limits Ref. ) and the calculated offsite doses will be well within the required lim its ( R f(c ni u d Brunswick Unit 1 B 3.1-6-1 Brunwic Uni 1 3.16-1Revision Nola I

Rod Pattern Control B 3.1.6 W-ý4k lkiREvk meA+'cds (Rev~s. 2 cwa 3)

BASES APPLICABLE Control rod patterns analyzed i R er follow the banked position SAFETY ANALYSES withdrawal sequence (BPWS). The BPWS is applicable from the (continued) condition of all control rods fully inserted to 8.75% RTP (Ref.

For the BPWS, the control rods are required to be moved in groups, with all control rods assigned to a specific group required to be within specified banked positions (e.g., between notches 08 and 12). The banked positions are established to minimize the maximum incremental control rod worth without being overly restrictive during normal plant operation.

NkWi GNF rmeAoas Generic analysis of the BPW I;has demonstrated that the 280 cal/gmn fuel damage limit will not be violated during a ORDA while following the BPWS during a plant startup or shutdown. The generic BPWS analysis

ý e.)also evaluates the effect of fully inserted, inoperable control rods otin compliance with the sequence, to allow a limited number (i.e.,

eight) and a required distribution of fully inserted, inoperable control rods. 4-Rod pattern control satisfies Criterion 3 of 10 CFR 50.36(c)(2)(ii)

Q(Ref. ).

LCO Compliance with the prescribed control rod sequences minimizes the potential consequences of a CRDA by limiting the initial conditions to those consistent with the BPWS. This LCO only applies to OPERABLE control rods. For inoperable control rods required to be inserted, separate requirements are specified in LCO 3.1.3, "Control Rod OPERABILITY," consistent with the allowances for inoperable control rods in the BPWS-APPLICABILITY In MODES 1 and 2, when THERMAL POWER is!* 8.75% RTP, the CRDA is a Design Basis Accident and, therefore, compliance with the assumptions of the safety analysis is required. When THERMAL POWER is > 8.75% RTP, there is no credible control rod configuration that results in a control rod worth that could exceed the 280 cal/gmn fuel dmgliit durin g a CRDA (Ref. ).In MODES 3, 4, and 5, since the reactor is shut down and interlocks allow only a single control rod to be withdrawn from a core cell containing fuel assemblies in MODE 5, adequate SDM ensures that the consequences of a CRDA are acceptable. This is due to the fact that the reactor will remain subcritical with a single control rod withdrawn.

(continued)

Brunswick Unit 1 B 3.1.6-2 Revision No.R)

Rod Pattern Control B 3.1.6 BASES ACTIONS B.

1 and B.2 (continued) to correct the position of control rods withdrawn beyond their allowed position is allowed since, in general, insertion of control rods has less impact on control rod worth than withdrawals have. Required Action BA1 is modified by a Note which allows an individual control rod to be bypassed in the RWM or the entire RWM to be bypassed to allow the affected control rods to be returned to their correct position. LCO 3.3.2.1 requires verification of control rod movement by a second licensed operator or other qualified member of the technical staff.

When nine or more OPERABLE control rods are not in compliance with BPWS, the reactor must be manually scrammed within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. This ensures the reactor is shut down and, as such, does not meet the applicability requirements of this LCO. The allowed Completion Time of 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> is reasonable to allow insertion of control rods to restore compliance, and is appropriate relative to the low probability of a CRDA occurring with the control rods out of sequence.

SURVEILLANCE SR 3.1.6.1 REQUIREMENTS The control rod pattern is verified to be in compliance with the BPWS at a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Frequency to ensure the assumptions of the CRDA analyses are met. The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Frequency was developed considering that the primary check on compliance with the BPWS is performed by the RWM (LCO 3.3.2. 1), which provides control rod blocks to enforce the required sequence and is required to be OPERABLE when operating at

<ý8.75% RTP.

REFERENCES

1.

UFSAR, Section 15.4.

NEDE-240 11-P-A-il1-US, General Electric Standard Application

~

for Reactor Fuel, Supplement for United States, Section 2.2.3.1, November 1995.

(continued)

3.

~ (P)A\\ Sie'~es Rower Corporo-.4iori PAt*%odo10 2 Y Po -o', Uni 4a.e-r Rea~c-4ors E~c#A.UQ;on-cnd -VcX,;do4,.f(0 of CASMo,/M~iC~oMUL4N-?,2)' (as 'Lcler+SifecL ir.

Whe C.OLO).

Brunswick Unit 1 B 3.1.6-4 Revision No.@

Rod Pattern Control B 3.1.6 BASES REFERENCES (continued)

NRC Safety Evaluation Report, Acceptance For Referencing of Licensing Topical Report NEDE-2401 1-P-A, General Electric Standard Application for Reactor Fuel, Revision 8, Amendment 17; December 27, 1987.

UFSAR, Section 4.3.2.5.

NUREG-0800, Section 15.4.9, Revision 2, July 1981.

NEDO-2 1778-A, Transient Pressure Rises Affected Fracture Toughness Requirements for Boiling Water Reactors, December 1978.

ASME, Boiler and Pressure Vessel Code.

10 CFR 50.67.

NEDO-21231, Banked Position Withdrawal Sequence, January 1977.

10 CFR 50.36(c)(2)(ii).

Brunswick Unit 1 B 3.1.6-5 Brunwic Uni 1

3.16-5Revision No.&J I

APLHGR B 3.2.1 B 3.2 POWER DISTRIBUTION LIMITS B 3.2.1 AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)

BASES BACKGROUND The APLHGR is a measure of the average LHGR of all the fuel rods in a fuel assembly at any axial locatio/n. Li s on the A PLH 11are sp/ecified to 9sure that the fu design limits id ntified in Refer e

1 r ot e eeded duin a icipated operati nal occurren/cesAOOs) and th the-INSRT akcladding te yer~ature (PCT) uring the postul ed design bas' loss of coolant accid t (LOCA) doe ot exceed the jits specified 10 CFR 50.46.1-ISIZand 1ry1 APPLICABLE The analytical methods and assumptions used in evaluating the fuel SAFETY ANALYSES design limits are presented in References a

,J The analytical methods and assumptions used in evaluating Design Basis Accidents (DBAs), anticipated operational transients, and normal operation that determine the APLHGR limits are presented in References 1, 2, 3, 4, 5, and 6v GN5~ Fuxe-Fuel design evaluations are performed to demonstrate that the 1 %/ limit on the fuel cladding plastic strain and other fuel design limits described in Reference 1 are not exceeded during AO0s for operation with LHGRs up to the operating limit LHGR. APLHGR limits are equivalent to the LHGR limit for each fuel rod divided by the local peaking factor of the fuel assembly. APLHGR limits are developed as a function of exposure and the various operating core flow and power states to ensure adherence to fuel design limits during the limiting AO0s.

Flow dependent APLHGR limits are determined using the three dimensional BWR simulator code (Ref. 7) to analyze slow flow runout transients. The flow dependent multiplier, MAPFACI, is dependent on the maximum core flow runout capability. The maximum runout flow is dependent on the existing setting of the core flow limiter in the Recirculation Flow Control System.

Based on analyses of limiting plant transients (other than core flow increases) over a range of power and flow conditions, power dependent multipliers, MAPFAC1,, are also generated. Due to the sensitivity of the (continued) 0 ýoc ý-he GNIF fuel ctn3 ReVerences H orJ Q f0r-4-be AREVA ý'Lxetl 9k.

Revision No.0 Brunswick Unit 1 B 3.2.1

INSERT B 3.

2.1 BACKGROUND

Limits on the APLHGR are specified to ensure that the peak cladding temperature (PCT) during the postulated design basis loss of coolant accident (LOCA) does not exceed the limits specified in 10 CFR 50.46. For GNF fuel, the APLHGR limits also ensure that the fuel design limits identified in Reference 1 are not exceeded during anticipated operational occurrences (AOOs).

APLHGR B 3.2.1 BASES APPLICABLE SAFETY ANALYSES (continued) transient response to initial core flow levels at power levels below those at which turbine stop valve closure and turbine control valve fast closure scram trips are bypassed, both high and low core flow MAP FACp limits are provided for operation at power levels between 23% RTP and the previously mentioned bypass power level. The exposure dependent APLHGR limits are reduced by MAPFACP and MAPFACf at various operating conditions to ensure that all fuel design criteria are met for normal operation and AO0s. A complete discussion of the analysis code is provided in Reference 8.

LOCA analyses are then performed to ensure that the above determined APLHGR limits are adequate to meet the POT and maximum oxidation limits of 10 CFR 50.46. The analysis is performed using calculational models that are consistent with the requirements of 10 CFR 50, Appendix K. A complete discussion of the analysis code is provided in Reference 9. The POT following a postulated LOCA is a function of the average heat generation rate of all the rods of a fuel assembly at any axial location and is not strongly influenced by the rod to rod power distribution within an assembly. The APLHGR limits specified are equivalent to the LHGR of the highest powered fuel rod assumed in the LOCA analysis divided by its local peaking factor. A conservative multiplier is applied to the LHGR assumed in the LOCA analysis to account for the uncertainty associated with the measurement of the APLHGR.

INSERT For single recirculation loop operation, Reference 5 shows that no APLHGR reduction is required.

The APLHGR satisfies Criterion 2 of 10 CFR 50.36(c)(2)(ii) (Ref. 10).

result of the fuel design, DBA, andI transient analyses. For two G W F L~e Irecirculation loops operating, the limit is determined by multiplying the G i D smaller of the MAPFACp and MAPFACt factors times the exposure dependent APLHGR limits. The APLHGR limits have been approved for the respective fuel and lattice type and determined by the approved methodology described in Reference 1. When hand calculations are required, the APLHGR for each type of fuel as a function of average planar exposure shall not exceed the limiting value, adjusted for core flow (continued)

Brunswick Unit 1 B 3.2.1-2 Brunwic Uni 1 3.21-2Revision No.02 I

INSERT B 3.2.1 APPLICABLE SAFETY ANALYSIS AREVA Fuel The analytical methods and assumptions used in evaluating the DBA that determine the APLHGR limit are presented in Reference 11. APLHGR limits are developed as a function of planar exposure.

LOCA analyses are performed to ensure that the APLHGR limits are adequate to meet the PCT and maximum oxidation limits of 10 CFR 50.46. The analysis is performed using analysis models that are consistent with the requirements of 10 CFR 50, Appendix K. The analysis models and methodology are described in Reference 11.

The AR EVA fuel APLHGR limits are presented in the COLR. For single recirculation loop operation, a multiplier is applied to the two recirculation loop operation exposure dependent APLHGR limits. This multiplier is due to an earlier departure from nucleate boiling with one recirculation loop available, resulting in a more severe cladding heatup during a LOCA.

APLHGR B 3.2.1 BASES LCO and core power, for the most limiting lattice (excluding natural uranium)

(continued) for each type of fuel shown in the applicable figures of the COLR. Limits have been provided in the COLR for two recirculation loop operation and single recirculation loop operation. The limits on single recirculation loop uoperation are provided to allow operation in this condition in conformance INS~~~T with the requirements of LCO3-.4.1, "Recircu'lat~ioun LoopsOeaig APP LICABILITY Th APL R Ii ts are nirn~ay der edi fr fue esgea in adA LCAa dtran ient a a[ Lse that e as med occ ath-.

e vels.

udies and operating experience hav show tht as power is re uced, the margin to the required APLHGR limits increases. This trend continues down to the power range of 5% to 15% RTP when entry into I KI SERT MODE 2 occurs. When in MODE 2, the intermediate range monitor scram G E function provides prompt scram initiation during any significant transient, thereby effectively removing any APLHGR limit compliance concern in MODE 2. At THERMAL POWER levels!ý 23% RTP, the reactor is operating with substantial margin to the APLHGR limits. For consistency with the 2.1.1.1 SL, this'power level was selected for LCO applicability.

ACTIONS A.1 If any APLHGR exceeds the required limits, an assumption regarding an initial condition of the DBA and transient analyses may not be met.

Therefore, prompt action should be taken and continued to restore the APLHGR(s) to within the required limits such that the. plant operates within analyzed conditions and within design limits of the fuel rods. The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time is sufficient to restore the APLHG R(s) to within its limits and is acceptable based on the low probability of a transient or DBA occurring simultaneously with the APLHGR out of specification.

B.1 It the APLHGR cannot be restored to within its required limits within the associated Completion Time, the plant must be brought to a MODE or other specified condition in which the LCO does not apply. To achieve (continued)

Brunswick Unit 1 B 3.2.1-3 Revision No.0

INSERT B 3.2.1 LCO:

AREVA Fuel The APLHGR limits specified in the COLR are the result of the DBA analyses.

For two recirculation loops operating, the limit is dependent on exposure. With only one recirculation loop in operation, in conformance with LCO 3.4.1, "Recirculation Loops Operating," the limit is determined by multiplying the exposure dependent APLHGR limit by a multiplier determined by a specific single recirculation loop analysis.

Additional APLHGR operating limits adjustments may be provided in the COLR to support analyzed equipment out-of-service operation.

INSERT B 3.2.1 APPLICABILITY:

The GNF fuel APLHGR limits are primarily derived from fuel design evaluations and LOCA and transient analyses that are assumed to occur at high power levels. The AREVA fuel APLHGR limits are derived from LOCA analyses that are assumed to occur at high power levels.

MCPR B 3.2.2 B 3.2 POWER DISTRIBUTION LIMITS B 3.2.2 MINIMUM CRITICAL POWER RATIO (MCPR)

BASES BACKGROUND MCPR is a ratio of the fuel assembly power that would result in the onset of boiling transition to the actual fuel assembly power. The MCPR Safety Limit (SL) is set such that 99.9% of the fuel rods avoid boiling transition if the limit is not violated (refer to the Bases for SL 2.1.1.2). The operating limit MCPR is established to ensure that no fuel damage results during anticipated operational occurrences (AQOs). Although fuel damage does not necessarily occur if a fuel rod actually experienced boiling transition (Ref.1), the critical power at which boiling transition is calculated to occur has been adopted as a fuel design criterion.

The onset of transition boiling is a phenomenon that is readily detected during the testing of various fuel bundle designs. Based on these experimental data, correlations have been developed to predict critical bundle power (i.e., the bundle power level at the onset of transition boiling) for a given set of plant parameters (e.g., reactor vessel pressure, flow, and subcooling). Because plant operating conditions and bundle power levels are monitored and determined relatively easily, monitoring the MCPR is a convenient way of ensuring that fuel failures due to inadequate cooling do not occur.

APPLICABLE SAFETY ANALYSES, IENS E R, TD The analytical ethods ad asuP~ ins used in evaluati the AO0s to establish e operating lImtM are presented in feerences 2, 3, 4 5,6,ap8. To ensure that t 99.9% of the fuel rsaviboln ftrasiti during any transie hat occurs with mo rate frequency, limit 'g transients are ana zed either with TRA or other 7hodologies. The s of transients eval ed are loss of fl fncrease in pressure nd power, positive r ctivity insertion, d coolant temperature decr se. The TRACG m odology calculat an operating limit MCPR (0 CPR) for the transie initial con~diti~on at will yield the largest chan in CPR (ACPR) res ting from the limi g transient. When the larges CPR is added to th CPR SL, an 0 CPR is obtained.

The

-- limiting of the OLM R calculated by her the TRACG or othe ethodology sets th ore operatfing Ii

ýeMCPR operating Ii its derived from t.

transient analysis e dependent on the o rating core flow a power state (MCP iand (continued)

Brunswick Unit I B 3.2.2-1 Brunwic Uni 1 3.22-1Revision Noe l

INSERT B 3.2.2 APPLICABLE SAFETY ANALYSIS:

The analytical methods and assumptions used in evaluating the AO0s to establish the operating limit MCPR are presented in References 2, 3, 4, 5, 7, 8, 9, and 10. To ensure that 99.9% of the fuel rods avoid boiling transition during any transient that occurs with moderate frequency, limiting transients are analyzed to determine the largest reduction in critical power ratio (CPR). The types of transients evaluated are loss of flow, increase in pressure and power, positive reactivity insertion, and coolant temperature decrease. The limiting transient yields the largest change in CPR (ACPR). When the largest ACPR is added to the MCPR SL, the required operating limit MCPR (OLMCPR) is obtained.

The MCPR operating limits derived from the transient analysis are dependent on the operating core flow and power state (MCPRf and MCPRp respectively) to ensure adherence to fuel design limit during the worst transient that occurs with moderate frequency as identified in the UFSAR Chapter 15 (Reference 5).

Flow dependent MCPR limits are determined using steady state thermal hydraulic methods (Reference 7) to analyze slow flow runout transients. The MCPRt limits are dependent on the maximum core flow runout capability of the Recirculation System.

Power dependent MCPR limits (MCPRp) are determined on a cycle-specific basis using the methodologies presented in References 8, 9, and 10. The MCPRp limits are established for a set of exposure intervals. Due to the sensitivity of the transient response to initial core flow levels at power levels below those at which turbine stop valve and/or turbine control valve fast closure and the associated scrams occur, high and low flow MCPRp operating limits may be provided for the following core power level ranges: 23 to 26% RTP and 26 to 40% RTP. The 26% RTP is the previously mentioned bypass power level and 40% RTP is the power level below which the power load unbalance unit (PLU) may not generate a turbine control valve fast closure on a generator loss of load event.

MCPR B 3.2.2 BASES APPLICABLE SAFETY ANALYSES (continued)

MCPRp, reectively) to sure adherenc/ to fuel dIe~sign ! its during the worst trient that oco rs with modera frequenc(R.7)

Flow ependent PR limits are termined using e methodology

/de ribed in Ref rence 2 to anal e slow flow ru ut transients. Th eerating limit' dependent o e maximum c e flow limiter setti g in he Recircull ion Flow Contr System.

Power de endent MCPR 'its (MOP Rp) ar determined usin the method ogy described' Reference 2.

ue to the sensitiv* of the transi nt response to' itial core flow le eIs at power level below those at whi the turbine st valv closu re d turbine control alve fast closur sams are bypas ed, higheacnd low, ow MCIPRP oper ing limits are rovided for op ating between 2 /o RTP and the p vously mention d bypass power evel.

The MCPR satisfies Criterion 2 of 10 CFR 50.36(c)(2)(ii) (RefkA, ý I

LCO The MCPR operating limits, as a function of core flow, core power, and cycle exposure, specified in the COLR are the result of the Design Basis Accident (DBA) and transient analysis. The operating limit MCPR is determined by the larger of the MCPRt and MCPRp limits.

APPLICABILITY The MCPR operating limits are primarily derived from transient analyses that are assumed to occur at high power levels. Below 23% RTP, the reactor is operating at a minimum recirculation pump speed and the moderator void ratio is small. Surveillance of thermal limits below 23% RTP is unnecessary due to the large inherent margin that ensures that the MCPRSL is not exceeded even if a limiting transient occurs.

Statistical analyses indicate that the nominal value of the initial MCPR expected at 23% RTP is > 3.5. Studies of the variation of limiting transient behavior have been performed over the range of power and flow conditions. These studies encompass the range of key actual plant parameter values important to typically limiting transients. The results of these studies demonstrate that a margin is expected between performance and the MCPR requirements, and that margins increase as (continued)

Brunswick Unit 1 B 3.2.2-2 Brunwic Uni 1

3.22-2Revision No. I

MCPR B 3.2.2 BASES SURVEILLANCE REQUIREMENTS SR 3.2.2.1 (continued) slowness of changes in power distribution during normal operation. The 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> allowance after THERMAL POWER Ž! 23% RTP is achieved is acceptable given the large inherent margin to operating limits at low power levels.

SR 3.2.2.2 Because the transient analysis takes credit for conservatism in the scram speed performance, it must be demonstrated that the specific scram speed distribution is consistent with that used in the transient analysis.

SR 3.2.2ý determines th vau fr hic his eurofteaa scram eed distributio compared with the sumed distributio. The MOP operating limit i then determined b ed on an interpol on Xbe een the applic le limits for Option scram times of L 3.1.4, ontrol Rod Scr Times") and Optio B (realistic scram mes) nalyses. The CPR operating limit or the Option AadOption B analyses are ecified in the COL

. The parameter T ust be determined once within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> afterec t of scram time te s required by SR 3.1.4., SR 3.1.4.2, and S

.1.4.4 because t effective scram speed tribution may chan during the cycle, he 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Comp tion Time' acceptable due to e relatively minor anges inTrexpecd dur' g the fuel cycle.

REFERENCES

1.

UFSAR Section 4.4.2.1.

2. JNE~p"-24O1,AS-A, Gen~pfal Electrlipttandard ý~(plication /

1 qactor Fuyf (latest a roved vwtion).

3.

UFSAR, Chapter 4.

A HCICAD r~,+C

5.

UFSAR, Chapter 15.

tSinnle-iiued)

ANt4-524MP(A')

~NtF Cr.Licak Power MAetk~oioly 4 Boiln W.4cer R~ecir-c~os.

Brunswick Unit 1 B 3.2.2-4 Brunwic Uni 1 3.22-4Revision No.g I

INSERT B 3.2.2 SURVEILLANCE REQUIREMENTS:

SR 3.2.2.2 determines the actual scram speed distribution and compares it with the assumed distribution. The MCPR operating limit is then determined based either on the applicable limit associated with scram times of LCO 3.1.4, "Control Rod Scram Times," or the realistic (nominal) scram times. The scram time dependent MCPR limits are contained in the COLR. This determination must be performed within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> after each set of control rod scram time tests required by SR 3.1.4.1, SIR 3.1.4.2, and SR 3.1.4.4 because the effective scram speed distribution may change during the cycle. The 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> Completion Time is acceptable due to the relatively minor changes in the actual control rod scram speed distribution expected during the fuel cycle.

INSERT B 3.

2.2 REFERENCES

7.

XN-NF-80-19(P)(A) Volume 3, "Exxon Nuclear Methodology for Boiling Water Reactors, THERMEX: Thermal Limits Methodology Summary Description," (as identified in the COLR).

8.

EMF-2158(P)(A), "Siemens Power Corporation Methodology for Boiling Water Reactors: Evaluation and Validation of CASMO-4/MICROBURN-B2," (as identified in the COLR).

9.

ANF-.913(P)(A) Volume 1, "COTRANSA2: A Computer Program for Boiling Water Reactor Transient Analyses,' (as identified in the COLR).

10.

XN-NF-84-1 05(P)(A), XCOBRA-T: A Computer Code for BWR Transient Thermal-Hydraulic Core Analysis," (as identified in the COLR).

11.

10 CFR 50.36(c)(2)(ii).

MCPR B 3.2.2 BASES R /ERENCES

7.

NED -'31654P, Maxiu tended Operatling Doýi am continued)

Ar aysis for Brunswick

ýearn Electric Plat Fe uary 1989.

8.

EDE-32906P-A, "T ACG Application for ticipated Operation Occurrences (AO Transient Analyses," pproved version as specified in

/theOLR.

9.

10O CFR 50 6(c)(2)(ii).

Brunswick Unit 1 B 3.2.2-5 Brunwic Uni 1 3.22-5Revision No.(9 I

LHGR B 3.2.3 B 3.2 POWER DISTRIBUTION LIMITS B 3.2.3 LINEAR HEAT GENERATION RATE (LHGR)

BASES BACKGROUND The LHGR is a measure of the heat generation rate of a fuel rod in a fuel assembly at any axial location. Limits on the LHGR are specified to ensure that fuel design limits are not exceeded anywhere in the core during normal operation, including anticipated operational occurrences (AOOs). Exceeding the LHGR limit could potentially result in fuel damage and subsequent release of radioactive materials. Fuel design limits are specified to ensure that fuel system damage, fuel rod failure or inability to cool the fuel does not occur during the anticipated operating conditions identified in References 1 and 2.

For GNF fuel, LCO 3.2.1 "AVEARGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)" ensures that the fuel design limits are not exceeded during normal operation and anticipated operational occurrences.

APPLICABLE SAFETY ANALYSES The analytical methods and assumptions used in evaluating the fuel system design are presented in References 1 and 2. The fuel assembly is designed to ensure (in conjunction with the core nuclear and thermal hydraulic design, plant equipment, instrumentation, and protection system) that the fuel damage will not result in the release of radioactive materials in excess of the guidelines of 10 CFR, Parts 20, 50, and 50.67.

The mechanisms that could cause fuel damage during normal operations and operational transients and that are considered in fuel evaluations are:

a.

Rupture of the fuel rod cladding caused by strain from the relative expansion of the U0 2 pellet; and

b.

Severe overheating of the fuel rod cladding caused by inadequate cooling A value of 1% plastic strain of the fuel cladding has been defined as the limit below which fuel damage caused by overstraining of the fuel cladding is not expected to occur (Ref. 3).

Fuel design evaluations have been performed and demonstrate that the 1 % fuel cladding plastic strain design limit is not exceeded during continuous operation with LHGRs up to the operating limit specified in the COLR. The analysis also includes allowances for short term transient operation above the operating limit to account for AO0s.

(continued)

Brunswick Unit 1 B 3.2.3-1 Brunwic Uni 1 3.23-1Revision No. XX

LHGR B 3.2.3 BASES APPLICABLE SAFETY ANALYSES (continued)

The LHGR limits are multiplied by the smaller of either the flow-dependent LHGR factor (LHGRFACf) or the power-dependent LHGR factor (LHGRFACp) corresponding to the existing core flow and power state to ensure adherence to the fuel mechanical design bases during the limiting transient.

Flow-dependent LHGR factors are determined using the three dimensional BWR simulator code (Reference 4) to analyze slow flow runout transients. The LHGRFACf is dependent on the maximum core flow runout capability of the Recirculation System.

Based on analyses of limiting plant transients (other than the slow flow runout event) over a range of power and flow conditions, power-dependent LHGR factors are generated. Due to the sensitivity of the transient response to initial core flow levels at power levels below those at which turbine stop valve and/or turbine control valve fast closure and the associated scrams occur, high and low flow LHGRFACp multipliers may be provided for the following core power level ranges:- 23 to 26% RTP and 26 to 40% RTP. The 26% RTP is the previously mentioned bypass power level and 40% RTP is the power level below which the power load unbalance unit (PLU) may not generate a turbine control valve fast closure on a generator loss of load event.

For GE fuel, no power-or flow-dependent LHGR factors are applied to the LHGR limits.

The LHGR satisfies Criterion 2 of 10 CFR 50.36(c)(2)(ii) (Reference 5)

LCO The LHGR is a basic assumption in the fuel design analysis. The fuel has been designed to operate at rated core power with sufficient design margin to the calculated LHGR which would cause a 1% fuel cladding plastic strain. The operating limit to accomplish this objective is specified in the COLR. Additional LHGR operating limits adjustments may be provided in the COLR to support analyzed equipment out-of-service operation.

APPLICABILITY The LHGR limits are derived from fuel design analysis that is limiting at high power level conditions. At core thermal power levels < 23% RTP, the reactor is operating with margin to the LHGR limits and, therefore, the Specification is only required when the reactor is operating at Ž! 23% RTP.

(continued)

Brunswick Unit 1B3232Reiono.X B 3.2.3-2 Revision No. XX

LHGR B 3.2.3 BASES ACTIONS A.1 If any LHGR exceeds its required limit, an assumption regarding an initial condition of the fuel design analysis in not met. Therefore, prompt action should be taken to restore the LHGR(s) to -within its required limits such that the plant is operating within analyzed conditions. The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time is normally sufficient to restore the LHGR(s) to within its limits and is acceptable based on the low probability of a transient or Design Basis Accident occurring simultaneously with the LHGR out of specification.

B.1 If the LHGR cannot be restored within its required limits within the associated Completion Time, the plant must be brought to a MODE or other specified condition in which the LCO does not apply. To achieve this status, THERMAL POWER is reduced to < 23% RTP within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

The allowed Completion Time is reasonable, based on operating experience, to reduce THERAL POWER to < 23% RTP in an orderly manner and without challenging plant systems.

SURVEILLANCE S R 3.2.3.1 REQUIREMENTS The LHGRs are required to be initially calculated within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> after THERMAL POWER is

> 23% RTP and then every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> thereafter.

They are compared with the LHGR limits in the GOLR to ensure that the reactor is operating within the assumptions of the safety analysis. The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Frequency is based on both engineering judgment and recognition of the slowness of changes in power distribution during normal operation. The 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> allowance after THERMAL POWER Ž: 23% RTP is acceptable given the large inherent margin to operating limits at low power levels.

REFERENCES 1.-

UFSAR, Chapter 4.

2.

UFSAR, Chapter 15.

3.

NUREG-0800, Section 4.2.11 A.2(g), Revision 2, July 1981.

4-EMF-21 58(P)(A), "Siemens Power Corporation Methodology for Boiling Water Reactors: Evaluation and Validation of CASMO-4/MICROBURN-B2," (as identified in the COLR).

5.

10 CFR 50.36(c)(2)(ii)

Brunswick Unit 1 B 3.2.3-3 Brunwic Uni 1 3.23-3Revision No. XX

RPS Instrumentation B 3.3. 1. 1 BASES APPLICABLE 21f Oscillation Power Rangie Monitor (OPRM) Upscale (continued)

SAFETY ANALYSES, LCO, and necessary to satisfy a Required Action, the APRM equipment is APPLICABILITY conservatively designed to force an OPRM Upscale trip output from the APRM channel if an APRM Inop condition occurs, such as when the APRM chassis keylock switch is placed in the Inop position.)

There are four "sets" of OPRM related setpoints or adjustment parameters: (a) OPRM trip auto-enable setpoints for Simulated Thermal Power (STP) (25%) and drive flow (60%); (b) period based detection algorithm (PBDA) confirmation count and amplitude setpoints; (c) period based detection algorithm tuning parameters; and (d) growth rate algorithm (GRA) and amplitude based algorithm (ABA) selpoints.

The first set, the OPRM auto-enable region setpoints, as discussed in the SR 3.3.1.1.19 Bases, are treated as nominal setpoints with no additional margins added. The settings, 25% APRM Simulated Thermal Power and 60% drive flow, are defined (limit values) in and confirmed by SR 3.3.1.1.19. The second set, the OPRM PBDA trip selpoints, are established in accordance with methodologies defined in Reference~

and are documented in the COLR. There are no allowable values for these setpoints. The third set, the OPRM PBDA "tuning" parameters, are established, adjusted, and controlled by plant procedures. The fourth set, the GRA and ABA setpoints, in accordance with References 15 and 16, are established as nominal values only, and controlled by plant procedures.

3. Reactor Vessel Steam Dome Pressure-Hicih An increase in the RPV pressure during reactor operation compresses the

,steam voids and results in a positive reactivity insertion. This causes the neutron flux and THERMAL POWER transferred to the reactor coolant to increase, which could challenge the integrity of the fuel cladding and the RCPB. The Reactor Vessel Steam Dome Pressure-High Function initiates a scram for transients that results in a pressure increase, counteracting the pressure increase by rapidly reducing core power. For the overpressurization protection analyses of References 4, (continued)

Brunswick Unit 1 B 3,3.1.1-15 Brunwic Unt 1 3..1.-15Revision Noo I

RPS Instrumentation B 3.3. 1.1 BASES REFERENCES

22.

General Electric Nuclear Energy Letter NSA 01 -21 2, (continued)

DRF 051 -00251-00, A. Chung (GE) to S. Chakraborty (GE),

"Minimum Number of Operable OPRM Cells for Option Ill Stability at Brunswick 1 and 2," June 8, 2001.

Brunswick Unit 1 B33114 eiinN B 3.3.1.1-43 Revision No.0 I

Control Rod Block Instrumentation B 3.3.2.1 BASES BACKGROUND (continued)

A rod block signal is also generated if an RBM inoperable trip occurs, since this could indicate a problem with the RBM channel. The inoperable trip will occur if, during the nulling (normalization) sequence, the RBM channel fails to null or too few LPRM inputs are available, if a critical self-test fault has been detected, or the RBM instrument mode switch is moved to any position other than "Operate."

The purpose of the RWM is to control rod patterns during startup and shutdown, such that only specified control rod sequences and relative positions are allowed over the operating range from all control rods inserted to 8.75% RTP. The sequences effectively limit the potential amount and rate of reactivity increase during a CRDA. Prescribed control rod sequences are stored in the RWM, which will initiate control rod withdrawal and insert blocks when the actual sequence deviates beyond allowances from the stored sequence. The RWM determines the actual sequence based position indication for each control rod. The RWM also uses steam flow signals to determine when the reactor power is above the preset power level at which the RWM is automatically bypassed. The RWM is a single channel system that provides input into the RMCS rod withdraw permissive circuit.

With the reactor mode switch in the shutdown position, a control rod withdrawal block is applied to all control rods to ensure that the shutdown condition is maintained. This Function prevents inadvertent criticality as the result of a control rod withdrawal during MODE 3 or 4, or during MODE 5 when the reactor mode switch is required to be in the shutdown position. The reactor mode switch has two channels, each inputting into a separate RMCS rod block circuit. A rod block in either RMCS circuit will provide a control rod block to all control rods.

APPLICABLE SAFETY ANALYSES,

1. Rod Block Monitor LCO, and The RBM is designed to prevent violation of the MCPR SL and the APPLICABILITY cladding 1 % plastic strain fuel design limit that may result from a single control rod withdrawal error (RWE) event. The analytical methods and

~e~eer-~es asum ionsused in evaluating the RWE event are summarized in efer ncA statistical analysis of RWE events was performed to (continu ed)

Brunswick Unit 1B3.2.-ResonN B 3.3.2.1-2 Revision No.9 I

Control Rod Block Instrumentation B 3.3.2.1 BASES APPLICABLE

1. Rod Block Monitor (continued)

SAFETY ANALYSES, LCO, and determine the RBM response for both channels for each event. From APPLICABILITY these responses, the fuel thermal performance as a function of RBM.ý Allowable Value was determined. The Allowable Values are chosen as a function of power level. Based on the specified Allowable Values, operating limits are establfish ed.'OL NG-The RBM Function satisfies Criterion 3 of 10 CFR 50.36(c)(2)(ii) (Ref. 3).

Two channels of the RBM are required to be OPERABLE, with their setpoints within the appropriate Allowable Value for the associated power range, to ensure that no single instrument failure can preclude a rod block from this Function. The actual setpoints are calibrated consistent with applicable setpoint methodology.

Trip setpoints are specified in the setpoint calculations. The setpoints are selected to ensure that the trip settings do not exceed the Allowable Values between successive CHANNEL CALIBRATIONS. Operation with a trip setting less conservative than the trip setpoint, but within its Allowable Value, is acceptable. A channel is inoperable if its actual trip setting is not within its required Allowable Value.

Trip setpoints are those predetermined values of output at which an action should take place. The setpoints are compared to the actual process parameter, the calculated RBM flux (RBM channel signal). When the RBM flux value exceeds the applicable setpoint, the RBM provides a trip output. The analytic limits are derived from the limiting values of the process parameters obtained from the safety analysis. The trip setpoints are determined from the analytic limits corrected for defined process, calibration, and instrument errors. The Allowable Values are then determined, based on the trip setpoint value, by accounting for calibration based errors. These calibration based instrument errors are limited to instrument drift, errors associated with measurement and test equipment, and calibration tolerance of LPRM input processing in the average power range monitor (APRM) equipment. The RBM performs only digital calculations on digitized LPRM signals received from the APRM equipment. The trip setpoints and Allowable Values determined in this manner provide adequate protection because instrumentation (continued)

Brunswick Unit 1 B 3.3.2.1-3 Revision No.

INSERT B 3.3.2.1 APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY:

With AREVA methods (References 11 and 12), cycle specific analyses are performed to establish MCPR limits and RBM setpoints considering allowed combinations of out of service LPRM instruments feeding the RBM channels, and assuming one RBM channel out of service.

Control Rod Block Instrumentation B 3.3.2.1 BASES APPLICABLE

1. Rod Block Monitor (continued)

SAFETY ANALYSES, LCO, and uncertainties, process effects, calibration tolerances, instrument drift, and APPLICABILITY environment errors are accounted for and appropriately applied~for the instrumentation.

orheq (Ito the liu omitsigaiedi the coneucs o no RWE evenilreut i exc6 dpraing th

%CP (Ref.

2). thi poefr, unery th e conditions, oh (STP refeence sIgnal inpuet from C S

anasoitd reerencete A RM i

chan trqel. the OPERABLE (Ranef is divde intthe"pwransa poe rS Ta angses is, respectvely, thet "lwitri a

etpint," th "ntermediate'o trip deftined u

in th e

CO

) To dterie the curen plowter range a chRB channl coprsiscrenvT nu au to thre powe se in the "ow power stphit" (29%) the"in teý90rmedwiate MPoweaer tehant"(urn valueq d otefin i

ced in the COL) and the "hg o

ervetint (currenut valu poer rang te is more f.2) restritiv thanr th e cors onding tpoint,

fo he TeRBM feluxtrpoupts an ftree automaetial bypse blutxh o

trip setpointstob cniustbeapplied tose inict the RBMen fllux ofpn onEMA theER TH UMAC ROWE displdiays.

oec BMcanlb asmltdthra oe (STP)refeencesignl inut fom anassoiateorefrenceAPR Brunswick Unit 1 B 3.3.2.1-4 BrunwickUnit1 B.3.21-4Revision No.0 I

INSERT B 3.3.2.1 APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY:

The RBM is assumed to mitigate the consequences of an RWE event when operating t> 29% RTP. Analyses demonstrate that below this power level the consequences of an RWE event will not exceed the MCPR SL and, therefore, the RBM is not required to be OPERABLE. Cycle specific analyses with Reference 11 and 12 methods are performed to establish an initial MCPR value above which the occurrence of an RWE event will not result in exceeding the MCPR SL while operating < 90% RTP. Cycle specific analyses are also performed to demonstrate that with MCPR greater than or equal to a specified value, no RWE event will result in exceeding the MCPR SL when operating

Ž! 90% RTP. The MCPR values for both < 90% RTP and Ž> 90% RTP are provided in the COLR. Under the conditions of RTP and MCPR specified in the COLR, the RBM is not required be OPERABLE.

Control Rod Block Instrumentation B 3.3.2.1 BASES APPLICABLE

1. Rod Block Monitor (continued)

SAFETY ANALYSES, LCO, and The calculated (required) setpoints and applicable power ranges are APPLICABILITY bounding values. In the equipment implementation, it is necessaryrto apply a "dleadband" to each setpoint. The dleadband is applied to the RBM trip setpoint selection logic and the RBM trip automatic bypass logic such that the setpoint being applied is always equal to or more conservative than the required setpoint. Since the RBMV flux trip setpoint applicable to the higher power ranges are more conservative than the corresponding trip setpoints for lower power ranges, the trip setpoint applicable to the higher power range (high power range or intermediate power range) continues to be applied when STP decreases below the lower limit of that range until STP is below the power range setpoint by a value exceeding the dleadband. Similarly, when STP decreases below the low power setpoint, the automatic bypass of RBM flux trip outputs will not be applied until STP decreases below the trip setpoint by a value exceeding the dleadband.

The RBM channel uses THERMAL POWER, as represented by the STP input value from its reference APRMV channel, to automatically enable RBM flux trip outputs (remove the automatic bypass) and to select the RBMV flux trip setpoint to be applied. However, the RBM Upscale function I+eValIues is only required to be OPERABLE when the MCPR values are Iess than Thereforineit 1.ev.Oden diouh h

onV Upsal FuALio RI ipemet. i each RBM channel as a single trip function with a selected trip setpoint, it is characterized in Table 3.3.2.1 -1 as three Functions, the Low Power Range-Upscale Function, the Intermediate Power Range-Upscale Function, and the High Power Range-Upscale Function, to facilitate correct definition of the OPERABILITY requirements for the functions.

Each Function corresponds to one of the RBM power ranges. Due to the dleadband effects on the determination of the current power range, the transition between these three Functions will occur at slightly different THERMAL POWER levels for increasing power versus decreasing power.

Since the RBMV flux trip setpoints applied for the higher power ranges are more conservative, the OPERABILITY requirement for the Low Power Range-Upscale Function is satisfied if the Intermediate Power Range-Upscale Function or the High Power Range-Upscale Function is (continued)

Brunswick Unit I B 3.3.2.1-5 Brunwic Unt 1B 33.21-5Revision No.('

I

Control Rod Block Instrumentation B 3.3.2.1 BASES APPLICABLE

1. Rod Block Monitor (continued)

SAFETY ANALYSES, LCO, and OPERABLE. Similarly, the OPERABILITY requirement for the APPLICABILITY Intermediate Power Range-Upscale Function is satisfied if the High Power Range-Upscale Function is OPERABLE.

2. Rod Worth Minimizer C

QýcIIZ The RWM enforces the banked position withdrawal sequence (BPWS) to ensure that the initial conditions of the CRDA analysis are not violated.

The analytical methods and assumptions used in evaluating the CRDA are summarized in References

, 5 n 6. T~he BPfWS requires that control rods be moved in groups, with all control rods assigned to a specific group required to be within specified banked positions.

Requirements that the control rod sequence is in compliance with the BPWS are specified in LCO 3.1.6, "Rod Pattern Control."

The RW M Function satisfies Criterion 3 of 10 CFR 50.36(c)(2)(ii) (Ref. 3).

The RWM is a microprocessor-based system with the principle task to reinforce procedural control to limit the reactivity worth of control rods under lower power conditions. Only one channel of the RWM is available and required to be OPERABLE. Special circumstances provided for in the Required Action of LCO 3.1.3, "Control Rod OPERABILITY," and LCO 3.1.6 may necessitate bypassing the RWMV to allow continued operation with inoperable control rods, or to allow correction of a control rod pattern not in compliance with the BPWS. As required by these conditions, one or more control rods may be bypassed in the RWM or the RWMV may be bypassed. However, the RWM must be considered inoperable and the Required Actions of this LCO followed since the RWM can no longer enforce compliance with the BPWS.

Compliance with the BPWS, and therefore OPERABILITY of the RWM, is required in MODES 1 and 2 when THERMAL POWER is *: 8.75% RTP.

When THERMAL POWER is > 8.75% RTP, there is no possible control rod configuration that results in a control rod worth that could exceed the 280 cal/gmn fuel damage limit during a CRDA (Refs. 5 and 6). In MODES 3 and 4, all control rods are required to be inserted into the core; (continued)

Brunswick Unit 1 R 3_3_2A-6 Brunwic Unt 1B 33.21-6Revision No.

I

Control Rod Block Instrumentation B 3.3.2.1 BASES (continued)

REFERENCES 1.

UFSAR, Section 7.6.1.1.5.

2.

NEDC-31654P, Maximum Extended Operating Domain Analysis For Brunswick Steam Electric Plant, February 1989.

3.

10 CFR 50.36(c)(2)(ii).

4.

NEDC-32466P, Power Uprate Safety Analysis Report for Brunswick Steam Electric Plant Unit 1 and 2, September 1995.

5.

UFSAR Section 15.4.

6.

NRC SER, Acceptance for Referencing of Licensing Topical Report NEDE-2401 1-P-A; General Electric Standard Application for Reactor Fuel, Revision 8, Amendment 17, December 27, 1987.

7.

GENE-770-06-1 -A, Bases for Changes to Surveillance Test Intervals and Allowed Out-of-Service Times for Selected Instrumentation Technical Specifications, December 1992.

8.

NEDC-30851 P-A, Supplement 1, Technical Specification Improvement Analysis for BWR Control Rod Block Instrumentation, October 1988.

9.

NEDC-32410P-A, Nuclear Measurement Analysis and Control Power Range Neutron Monitor (NUMAC PRNM) Retrofit Plus Option Ill Stability Trip Function, October 1995.

10.

NEDC-32410P-A Supplement 1, Nuclear Measurement Analysis and Control Power Range Neutron Monitor (NUMAC PRNM)

IAs E RT Retrofit Plus Option filt Stability Trip Function, November 1997.

Brunswick Unit 1 B33211 eiinN B 3.3.2.1-15 Revision No.0 I

INSERT B 3.3.

2.1 REFERENCES

11.

XN-NF-80-19(P)(A) Volume 1, "Exxon Nuclear Methodology for Boiling Water Reactors - Neutronic Methods for Design and Analysis," (as identified in the COILR).

12.

EMF-2158(P)(A), "Siemens Power Corporation Methodology for Boiling Water Reactors: Evaluation and Validation of CASMO-4/MICROBURN-B2," (as identified in the COILR).

Feedwater and Main Turbine High Water Level Trip Instrumentation B 3.3.2.2 BASES APPLICABLE The high water level trip indirectly initiates a reactor scram from the main SAFETY ANALYSES turbine trip (above 26% RTP) and trips the feedwater pumps, thereby (continued) terminating the event. The reactor scram mitigates the reduction in MCPR or Fedater ýand ýmain turbine ýigh w~ater 'eveltrip ntuetto aife Criterion 3 of 10 CFR 50.36(c)(2)(ii) (Ref. 2).

LCO The LCO requires three channels of the reactor vessel high water level instrumentation to be OPERABLE to ensure that the feedwater pump turbines and main turbine trip on a valid high water level signal. Two of the three channels are needed to provide trip signals in order for the feedwater and main turbine trips to occur. Each channel must have its setpoint set within the specified Allowable Value of SR 3.3.2.2.2. The Allowable Value is set to ensure that the thermal limits are not exceeded during the event. The actual setpoint is calibrated to be consistent with the applicable setpoint methodology assumptions. Trip setpoints are specified in the setpoint calculations. The setpoints are selected to ensure that the trip settings do not exceed the Allowable Value between successive CHANNEL CALIBRATIONS. Operation with a trip setting less conservative than the trip setpoint, but within its Allowable Value, is acceptable. A channel is inoperable if its actual trip setting is not within its required Allowable Value.

Trip setpoints are those predetermined values of output at which an action should take place. The setpoints are compared to the actual process parameter (e.g., reactor vessel water level), and when the measured output value of the process parameter exceeds the setpoint, the associated device (e.g., trip unit) changes state. The analytic limits are derived from the limiting values of the process parameters obtained from the safety analysis. The trip setpoints are determined from the analytic limits corrected for defined process, calibration, and instrument errors.

The Allowable Values are then determined, based on the trip setpoint values, by accounting for calibration based errors. These calibration based instrument errors are limited to instrument drift, errors associated with measurement and test equipment, and calibration tolerance of loop components. The trip setpoints and Allowable Values determined in this manner provide adequate protection because (continued)

Brunswick Unit 1 B 3-3.2.2-2 BrunwickUnit1 B.3.22-2Revision No.0 I

Feedwater and Main Turbine High Water Level Trip Instrumentation B 3.3.2.2 crid LCO0 '3.2-3) L i mE A R1HEAVI CGEINERAMTOI.

RA~TE, BASES LCO (continued) instrumentation uncertainties, process effects, calibration tolerances, instrument drift, and severe environment errors (for channels that must function in harsh environments as defined by 10 CFR 50.49) are accounted for and appropriately applied for the instrumentation.

APPLICABILITY The feedwater and main turbine high water level trip instrumentation is required to be OPERABLE at Ž! 23% RTP to ensure that the fuel cladding integrity Safety Limit and the cladding 1 % plastic strain limit are not violated during the feedwater controller failure, maximum demand event.

As discussed in the Bases for LCO 3.2.1, "Average Planar Linear Heat Generation Rate (APLHGR),"(aLCO 3.2.2, 'MINIMUM CRITICAL POWER RATIO (MCPR)\\ý sufficient margin to these limits exists below 23% RTP; therefore, these requirements are only necessary when operating at or above this power level.

ACTIONS A Note has been provided to modify the ACTIONS related to feedwater and main turbine high water level trip instrumentation channels.

Section 1.3, Completion Times, specifies that once a Condition has been entered, subsequent divisions, subsystems, components, or variables expressed in the Condition, discovered to be inoperable or not within limits, will not result in -separate entry into the Condition. Section 1.3 also specifies that Required Actions of the Condition continue to apply for each additional failure, with Completion Times based on initial entry into the Condition. However, the Required Actions for inoperable feedwater and main turbine high water level trip instrumentation channels provide appropriate compensatory measures for separate inoperable channels.

As such, a Note has been provided that allows separate Condition entry for each inoperable feedwater and main turbine high water level trip instrumentation channel.

A. 1 With one channel inoperable, the remaining two OPERABLE channels can provide the required trip signal. However, overall instrumentation reliability is reduced because a single failure in one of the remaining channels concurrent with feedwater controller failure, maximum demand (continued)

Brunswick Unit 1 B 3.3.2.2-3 Brunwic Unt 1B 33.22-3Revision No.0) I

Feedwater and Main Turbine High Water Level Trip Instrumentation B 3.3.2.2 ACTIONS B.1 (continued)

With the required channels not restored to OPERABLE status or placed in trip, THERMAL POWER must be reduced to < 23% RTP within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

As discussed in the Applicability section of the Bases, operation below 23% RTP results in sufficient margin to the required limits, and the feedwater and main turbine high water level trip instrumentation is not required to protect fuel integrity during the feedwater controller failure, maximum demand event. The allowed Completion Time of 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> is based on operating experience to reduce THERMAL POWER to

< 23% RTP from full power conditions in an orderly manner and without challenging plant systems.

SURVEILLANCE REQUIREMENTS The Surveillances are modified by a Note to indicate that when a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided the associated Function maintains feedwater and main turbine high water level trip capability. Upon completion of the Surveillance, or expiration of the 6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> allowance, the channel must be returned to OPERABLE status or the applicable Condition entered and Required Actions taken. This Note is based on the reliability analysis (Ref. 3) assumption that 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> is the average time required to perform channel Surveillance. That analysis demonstrated that the 6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> testing allowance does not significantly reduce the probability that the feedwater pump turbines and main turbine will trip when necessary.

SR 3.3.2.2.1 Performance of the CHANNEL CHECK once every 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> ensures that a gross failure of instrumentation has not occurred. A CHANNEL CHECK is normally a comparison of the parameter indicated on one channel to a (continued)

Brunswick Unit 1B33.2-ReionN.

B 3.3.2.2-5 Revision No.0 I

EGOS Instrumentation B 3.3.5.1 BASES APPLICABLE SAFETY ANALYSES LCO, and APPLICABILITY (continued)

I Core Spray and Low Pressure Coolant Injection Systems 1.a. 2.a. Reactor Vessel Water Level-Low Level 3 Low reactor pressure vessel (RPV) water level indicates that the capability to cool the fuel may be threatened. Should RPV water level decrease too far, fuel damage could result. The low pressure EGOS and associated DGs are initiated at Reactor Vessel Water Level-Low Level 3 to ensure that core spray and flooding functions are available to prevent or minimize fuel damage. The Reactor Vessel Water Level-Low Level 3 is one of the Functions assumed to be OPERABLE and capable of initiating the ECCS and associated DGs during the transients analyzed in References 1 and 3. In addition, the Reactor Vessel Water Level-Low Level 3 Function is directly assumed in the analysis of the recirculation line break

~The core cooling function of the EGGS, along with the scram action of the Reactor Protection System (RPS), ensures that the fuel peak cladding temperature remains below the limits of 10 CFR 50.46.

Reactor Vessel Water Level-Low Level 3 signals are initiated from four level transmitters that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel.

The Reactor Vessel Water Level-Low Level 3 Allowable.Value is chosen to allow time for the low pressure core flooding systems to activate and provide adequate cooling. The Allowable Value is referenced from reference level zero. Reference level zero is 367 inches above the vessel zero point.

Four channels of Reactor Vessel Water Level-Low Level 3 Function are only required to be OPERABLE when the ECCS or OG(s) are required to be OPERABLE to ensure that no single instrument failure can preclude EGGS and DG initiation. Refer to LCO 3.5.1 and LCO 3.5.2, "ECCS-Shutdown," for Applicability Bases for the low pressure EGGS subsystems; and LGO 3.8.1 and LCO, 3.8.2, "AC Sources-Shutdown," for Applicability Bases for the DGs.

1.b. 2.b. Drvwell Pressure-Hicqh High pressure in the drywell could indicate a break in the reactor coolant pressure boundary (RCPB). The low pressure EGGS and associated (continued)

Brunswick Unit 1 B 3.3.5.1-8 Bruswik nit1 B3..5.-8Revision No.%D

ECCS Instrumentation The

~y~eI ?rss~r-

~B 3.3.5.1 ex~ic4ly use tir I-he AREVA o~rnclys's cS +-heL BASES reircuka4ion tine Iweo~k since c4 es na oV c+

+he timd~ina 1-00%.

APPLICABLE 1.b,T2b. Drvwell Pressure-Hi-gh (continued)

SAFETY ANA LCD, and APPLICABILIf

LYSES, DGs are initiated upon receipt of the Drywell Pressure-High Function ry coincident with Reactor Steam Dome Pressure-Low Function in order to m1inimize the possibility of fuel damage. The Drywell Pressure-High Fu nction is directly assumed in thejanalysis of the recirculation line break A IXf The core cooling function of the ECCS, along with the scram action of the RPS, ensures that the fuel peak cladding temperature remains below the limits of 10 CFR 50.46.

High drywell pressure signals are initiated from four pressure transmitters that sense drywell pressure. The Allowable Value was selected to be as low as possible to be indicative of a LOCA inside primary containment.

The Drywell Pressure-High Function is required to be OPERABLE when the ECGS or DG is required to be OPERABLE in conjunction with times when the primary containment is required to be OPERABLE. Thus, four channels of the CS and LPCI Drywell Pressure-High Functions are required to be OPERABLE in MODES 1, 2, and 3 to ensure that no single instrument failure can preclude ECCS and DG initiation. In MODES 4 and 5, the Drywell Pressure-High Function is not required, since there is insufficient energy in the reactor to pressurize the primary containment to Drywell Pressure-High setpoint. Refer to LCD 3.5.1 for Applicability Bases for the low pressure ECCS subsystems and to LCD 3.8.1 for Applicability Bases for the DGs.

1.c. 2.c. Reactor Steam Dome Pressure-Low Low reactor steam dome pressure signals are used as permissives for the low pressure ECCS subsystems. This ensures that, prior to opening the injection valves of the low pressure EGGS subsystems, the reactor pressure has fallen to a value below these subsystems' maximum design pressure. The low reactor steam dome pressure signals are also used in the Drywell Pressure-High logic circuits to distinguish high drywell pressure caused by a LOCA from that caused by loss of drywell cooling.

The Reactor Steam Dome Pressure-Low is one of the Functions assumed to be OPERABLE and capable of permitting initiation of the EGGS and associated DGs during the transients analyzed in References 2 and 3. In addition, the Reactor Steam Dome (continued)

Brunswick Unit 1 B 3.3.5.1-9 Brunwic Unt 1B 33.51-9Revision No.09 I

ECCS Instrumentation B 3.3.5.1 BASES APPLICABLE 1.c, 2.c. Reactor Steam Dome Pressure-Low (continued)

SAFETY ANALYSES, LGO, and Pressure-Low Function is directly assumed in the analysis of the APPLICABILITY recirculation line break.-

hecr coig ucio fth GS along with the scram action of the RPS, ensures that the fuel peak cladding temperature remains below the limits of 10 CFR 50.46.

The Reactor Steam Dome Pressure-Low signals are initiated from four pressure transmitters that sense the reactor dome pressure.

The Allowable Value is low enough to prevent overpressuring the equipment in the low pressure EGGS, but high enough to ensure that the EGGS injection prevents the fuel peak cladding temperature from exceeding the limits of 10 CFR 50.46.

Four channels of Reactor Steam Dome Pressure-Low Function are only required to be OPERABLE when the EGGS or DG(s) are required to be OPERABLE to ensure that no single instrument failure can preclude EGGS and DG initiation. Refer to LCO 3.5.1 and LCD 3.5.2 for Applicability Bases for the low pressure EGGS subsystems; and LCO 3.8.1 and LCO 3.8.2 for Applicability Bases for the DGs.

14.d 21f Core Spray and RHR Pump Start-Time Delay Relays The purpose of these time delays is to stagger the start of the CS and RHR pumps that are in each of Divisions I and 1I, thus limiting the starting transients on the 4.16 kV emergency buses. These Functions are necessary when power is being supplied from either the normal power sources (offsite power) or the standby power sources (DGs). The Gore Spray Pump Start-Time Delay Relays and the RHR Pump Start-Time Delay Relays are assumed to be OPERABLE in the accident and transient analyses requiring EGGS initiation. That is, the analyses assume that the pumps will initiate when required and excess loading will not cause failure of the power sources.

There are eight RHR Pump Start-Time Delay Relays, two channels in each of the RHR pump start logic circuits. There are six CS pump start timers arranged such that there are four separate channels of the Core Spray Pump Start Time-Delay Relay Function, two channels in each of the CS pump start logic circuits. Each channel consists of an individual (continued)

Brunswick Unit 1 B 3.3.5.1 -10 Brunwic Unt 1 3..5.-10Revision No.0

ECOS Instrumentation B 3.3.5.1 BASES APPLICABLE 2.d. Reactor Steam Dome Pressure-Low (Recirculation Pump SAFETY ANALYSES Dischargie Valve Permissive) (continued)

LCO, and APPLICABILITY be OPERABLE and capable of closing the valve(s) during !he transients analyzed in References 2 and 3. The core cooling function of the ECCS, along with the scram action of the RIPS, ensures that the fuel peak cladding temperature remains below the limits of 10 CFR 50.46. The Reactor Steam Dome Pressure-Low Function is directly assumed in the analysis of the recirculation line braa The Reactor Steam Dome Pressure-Low signals are initiated from four pressure transmitters that sense the reactor dome pressure.

The Allowable Value is chosen to ensure that the valves close prior to commencement of LPCI injection flow into the core, as assumed in the safety analysis.

Four channels of the Reactor Steam Dome Pressure-Low Function are only required to be OPERABLE in MODES 1, 2, and 3 with the associated recirculation pump discharge valve open or the associated recirculation pump discharge bypass valve open. With the valve(s) closed, the function of instrumentation has been performed; thus, the Function is not required.

In MODES 4 and 5, the loop injection location is not critical since LPCI injection through the recirculation loop in either direction will still ensure that LPCI flow reaches the core (i.e., there is no significant reactor steam dome back pressure).

2.e. Reactor Vessel Shroud Level The Reactor Vessel Shroud Level Function is provided as a permissive to allow the RHR System to. be manually aligned from the LPCI mode to the suppression pool cooling/spray or drywell spray modes. The permissive ensures that water in the vessel is at least two thirds core height before the manual transfer is allowed. This ensures that LPCI is available to

.prevent or minimize fuel damage. This function may be overridden during accident conditions as allowed by plant procedures. The Reactor Vessel Shroud Level Function is implicitly assumed in the analysis of the recirculation line break e.

since the analysis assumes that no LPCI

--(continued)

Brunswick Unit 1 B 3.3.5.1-12 Brunwic Unt 1 3..5.-12Revision No@ I

ECOS Instrumentation B 3.3.5.1 BASES APPLICABLE 3.e. Suppression Chamber Water Level,-Hicih (continued)

SAFETY ANALYSES, LCO, and Two channels of Suppression Chamber Water Level-High Function are APPLICABILITY required to be OPERABLE only when HPCI is required to be OPERABLE (continued) to ensure that no single instrument failure can preclude HPCI swap to suppression pool source. Refer to LCO 3.5.1 for HPCI Applicability Bases.

Automatic Depressurization System (ADS) 4.a. 5.a. Reactor Vessel Water Level-Low Level 3 Low RPV water level indicates that the capability to cool the fuel may be threatened. Should RPV water level decrease too far, fuel damage could result. Therefore, ADS receives one of the signals necessary for initiation evenils Lknctyzed from this Function. The Reactor Vessel Water Level-Low Level 3 is one of the Functions assumed to be OPERABLE andicaa ble of initiating the tn KeF'erenc~e 2.

AD duigteacld~ent rnalved in) eýernce~. anyj The core cooling function of the ECCS, along with the scram action of the RPS, ensures that the fuel peak cladding temperature remains below the limits of 10 CFR 50.46.

Reactor Vessel Water Level-Low Level 3 signals are initiated from four level transmitters that sense the 'difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel. Four channels of Reactor Vessel Water Level-Low Level 3 Function are required to be OPERABLE only when ADS is required to be OPERABLE to ensure that no single instrument failure can preclude ADS initiation. Two channels input to ADS trip system A, while the other two channels input to ADS trip system B. Refer to LCO 3.5.1 for ADS Applicability Bases.

The Reactor Vessel Water Level-Low Level 3 Allowable Value is chosen to allow time for the low pressure core flooding systems to initiate and provide adequate cooling. The Allowable Value is referenced from reference level zero. Reference level zero is 367 inches above the vessel zero point.

(continued)

Brunswick Unit 1 B33511 eiinN B 3.3.5.1-17 Revision No.0 I

EGGS Instrumentation B 3.3.5.1 BASES APPLICABLE 4.b, 5.b. ADS Timer SAFETY ANALYSES, LCO, and The purpose of the ADS Timer is to delay depressurization of the reactor APPLICABILITY vessel to allow the HPCI System time to maintain reactor vessel water (continued) level. Since the rapid depressurization caused by ADS operation is one of

,the most severe transients on the reactor vessel, its occurrence should be limited. By delaying initiation of the ADS Function, the operator is given the chance to monitor the success or failure of the HPCI System to maintain water level, and then to decide whether or not to allow ADS to initiate, to delay initiation further by recycling the timer, or to inhibit initiation permanently. The ADS Timer Function is assumed to be OPERABLE for the accident analyses of Referencer2l(6dýhat require EGGS initiation and assume unavailability of the HPCI System.

There are two ADS Timer relays, one in each of the two ADS trip systems.

The Allowable Value for the ADS Timer is chosen to be long enough to allow HPCI to start and avoid an inadvertent blowdown yet short enough so that there is still time after depressurization for the low pressure EGGS subsystems to provide adequate core cooling.

Two channels of the ADS Timer Function are only required to be OPERABLE when the ADS is required to be OPERABLE to ensure that no single instrument failure can preclude ADS initiation. One channel inputs to ADS trip system A, while the other channel inputs to ADS trip system B. Refer to LCO 3.5.1 for ADS Applicability Bases.

4.c. 5.c. Reactor Vessel Water Level-Low Level 1 I

The Reactor Vessel Water Level-Low Level 1 Function is used by the ADS only as a confirmatory low water level signal. ADS receives one of the signals necessary for initiation from Reactor Vessel Water Level-Low Level 3 signals. In order to prevent spurious initiation of the ADS due to spurious Level 3 signals, a Level 1 signal must also be received before ADS initiation commences.

Reactor Vessel Water Level-Low Level 1 signals are initiated from two level transmitters that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel. The Allowable Value for (continued)

Brunswick Unit 1 B 33.51-18 Brunwic Uni 1 335-18Revision No.0? I

ECCS Instrumentation B 3.3.5.1 BASES APPLICABLE 4.c, 5.c. Reactor Vessel Water Level-Low Level 1 (continued)

SAFETY ANALYSES, LCO, and Reactor Vessel Water Level-Low Level 1 is selected at the RPS Level 1 APPLICABILITY scram Allowable Value for convenience. Refer to LCO 3.3.1.1, "Reactor Protection System (RPS) Instrumentation," for the Bases discussion of this Function. The Allowable Value is referenced from reference level zero. Reference level zero is 367 inches above the vessel zero point.

Two channels of Reactor Vessel Water Level-Low Level 1 Function are only required to be OPERABLE when the ADS is required to be OPERABLE to ensure that no single instrument failure can preclude ADS initiation. One channel inputs to ADS trip system A, while the other channel inputs to ADS trip system B. Refer to LGO 3.5.1 for ADS Applicability Bases.

4Ad 4.e, 5.d. 5.e. Core Spray and RHR (LPCI Mode) Pump Discharge Pressure-High The Pump Discharge Pressure-High signals from the CS and RHR pumps are used as permissives for ADS initiation, indicating that there is a source of low pressure cooling water available once the ADS has depressurized the vessel. Pump Discharge Pressure-High is one of the Functions assumed to be OPERABLE and capable ofpermitting ADS initiation during the events analyzed in ReferenceT2W Dwith an assumed HPCI unavailability. For these events the ADS depressurizes the reactor vessel so that the low pressure ECCS can perform the core cooling functions. This core cooling function of the ECCS, along with the scram action of the RPS, ensures that the fuel peak cladding temperature remains below the limits of 10 CFR 50.46.

Pump discharge pressure signals are initiated from twelve pressure switches, two on the discharge side of each of the six low pressure ECOS pumps. In order to generate an ADS permissive in one trip system, it is necessary that only one CS pump (both channels for the pump) indicate the high discharge pressure condition or two RHR pumps in one LPCI loop (one channel for each pump) indicate a high discharge pressure condition. The Pump Discharge Pressure-High Allowable Value is less than the pump discharge pressure when the pump is operating at all flow ranges and high enough to avoid any condition that results in a discharge (continued)

Brunswick Unit 1 B33511 eiinN B 3.3-5.1-19 Revision No.0 I

ECCS Instrumentation B 3.3.5.1 BASES SURVEILLANCE REQUIREMENTS (continued)

SR 3.3,5.1.5 The LOGIC SYSTEM FUNCTIONAL TEST demonstrates the OPERABILITY of the required initiation logic and simulated automatic operation for a specific channel. The system functional testing performed in LCO 3.5.1, LCO 3.5.2, LCO 3.8.1, and LCO 3.8.2 overlaps this Surveillance to complete testing of the assumed safety function.

Based on minimal assumed risk in performing this Surveillance with the reactor at power, the surveillance is not required to be performed during a refueling outage. Operating experience has demonstrated that these components will usually pass the SIR when performed at the 24 month Frequency (originally based on the refueling cycle). Therefore, the Frequency is concluded to be acceptable from a reliability standpoint.

REFERENCES 1.UFSAR, Section 5.2.

2.

UFSAR, Section 6.3.

3.

UFSAR, Chapter 15.

4.

10 CFR 50.36(c)(2)(ii),

6.

UFSAR, Section 9.2.6.2.

7.

NEDC-30936-P-A, BWR Owners'Group Technical Specification Improvement Methodology (With Demonstration for BWR ECCS Actuation Instrumentation), Parts 1 and 2, December 1988.

Brunswick Unit 1 B 3.3.5.1-31 Brunwic Unt 1

3..5.-31Revision No.e

Recirculation Loops Operating

'The AZE~VA LOCA, cnalyses atSSwkne MjrnQsr+Ched B 3.4.1 ft*.i n hereicul~on tof s C

I~

GFc n~ses, BASES 44 e a~cd se OSLAe JI-a-oh ops 0r pec-i 1 c

+hescie Z~ct.. rior 't+

acd. n The GNF n BACKGROUND coolant begins to boil, creating steam voids within the fuel channel that (continued) continue until the coolant exits the core. Because of reduced moderation, the steam voiding introduces negative reactivity that must be compensated for to maintain or to increase reactor power. The recirculation flow control allows operators to increase recirculation flow which increases the overall core heat transfer. As a result, core voiding is reduced thereby overcoming the negative reactivity void effect. Thus, the

^

fnw h-a~

wn~n rne-irr., Infien fienA io fn~ ý ne f-~

reactivity effects of boiling over a wide range of power generation (i.e.,

approximately 60 to 100% of RTP) without having to move control rods and disturb desirable flux patterns.

Each recirculation loop is manually started from the control room. The MG set provides regulation of individual recirculation loop drive flows.

The flow in each loop is manually controlled.

APPLICABLE The operation of the Reactor Recirculation System is an initial condition SAFETY ANALYSES assumed in the design basis loss of coolant accident (LOCA). During a LOCA caused by a recirculation loop pipe break, the intact loop is assumed to provide coolant flow during the first few seconds of the accident. The initial core flow decrease is rapid because the recirculation thep cid'e brke Hoop everses LoC anlyiswa revieedtor coatt the cassel wihaflmowt imeisatcl.he between the itwot loops wiath then pebrelakiel assumed. Tohein thep loopwit thvernhighecre flow.

Whiespthe flow catdoe andx covrel respondse aruptntialy tejtpmor severeion tis assumeed. cashe/

(since the intact loop starts at a lower flow rate and the core response is the same as if both loops were operating at a lower flow rate), a small mismatch has been determined to be acceptable based on en ieei judgement.

hýere clat syrfst isals?/ ssume to have fficient oi coas ow Z racuteri tics t, aintaiulte al margi s durin nor I ope~rtional tr si~ent (Ref. 1)hich a annalyze in Chap r15o he UF R(

f2)

(continued)

~hcI r nadye

'n CV,%OP-er 15' of' +Vie LAFnPR (fReVP. 2).

Brunswick Unit 1B341-ReionN.

B 3.4.1-2 Revision No.&

I

Recirculation Loops Operating B 14.1 APPLICABLE SAFETY ANALYSE~

(continued)

.IYplant spg6ific [OCX Ir4 SERT1 3Wperatin94ecirculat' n loop. This analytis has demonstrated that, in the-event of a LOCA caused by a pipe break in the operating recirculation loop, the Emergency Core Cooling System response will provide adequate core cooling, without the requirement to modify the APLHGR requirements (Ref. 3). However, the COLIR may require APLHGR limits to restrict the peak clad temperature for a LOCA with a single recirculation loop operating below the corresponding temperature for both loops operating.

IThfitrans/ient a lyses of Ch ter 15 of th UFSAR Xave also een

,p$rformed for ngle recircul tion loop op ation (R nde tý9.

3) and emonstr e

,9$ufficient flo coastdown iaracteristics o mainta' fuel the mal marg s during the normal oper tional transie ts analy* d witho the req uirem t to mo dif t e MCPR req eIents. I uring single recirculation loop operation, modification to the Reactor Protection System (RPS) average power range monitor (APRM) Simulated Thermal Power-High Allowable Value is required to account for the different analyzed limits between two-recirculation drive flow loop operation and operation with only one loop. The APRM channel subtracts the AW value from the measured recirculation drive flow to effectively shift the limits and uses the adjusted recirculation drive flow value to determine the APRM Simulated Thermal Power-High Function trip setpoint.

Recirculation loops operating satisfies Criterion 2 of 10 CFR 50.36(c)(2)(ii) (Ref. 4).

LCO Two recirculation loops are normally required to be in operation with their recirculation pump speeds matched within the limits specified in SR 3.4.1.1 to ensure that during a LOCA caused by a break of the piping of one recirculation loop the assumptions of the LOCA analysis are satisfied. Alternately, with only one recirculation loop in operation, modifications to the required APLHGR limits (LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)"), MCPR limits (LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)"),yand APIRM Simulated Thermal Power-High Allowable Value (LCO 3.3.1.1), as (continued)

LHCGP 1,m4s(LCco3.2.3, "LINEAR H-EAT7-GEN n*j 0., (LRKEE 3 Brunswick Unit 1 B 3.4.1-3 Brunwic Uni 1 3.41-3Revision No.0 I

INSERT B 3.4.1 APPLICABLE SAFETY ANALYSES:

For ARE VA fuel, the COLR presents single loop operation APLHGR limits in the form of a multiplier that is applied to the two loop operation APLHGR limits.

The transient analyses of Chapter 15 of the UFSAR have also been evaluated for single recirculation loop operation. The evaluation concludes that results of the transient analyses are not significantly affected by the single recirculation loop operation. There is, however, an impact on the fuel cladding integrity SL since some of the uncertainties for the parameters used in the critical power determination are higher in single loop operation. The net result is an increase in the MCPR operating limit.

Recirculation Loops Operating B 3.4. 1 BASES LCO applicable, must be applied to allow continued operation. The COLR (continued) dfnsajtmtsor modifications required for the APLHGRW)jZ4 CPR~mitsfor the current operating cycle.

APPLICABILITY In MODES 1 and 2, requirements for operation of the Reactor Coolant Recirculation System are necessary since there is considerable energy in the reactor core and the limiting design basis transients and accidents are assumed to occur.

In MODES 3, 4, and 5, the consequences of an accident are reduced and the coastdown characteristics of the recirculation loops are not important.

ACTIONS A. 1 With the requirements of the LCO not met, the recirculation loops must be restored to operation with matched recirculation pump speeds within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. A recirculation loop is considered not in operation when the pump in that loop is idle or when the difference in pump speeds of the two recirculation pumps is greater than the match criteria. The loop with the lower recirculation pump speed must be considered not in operation.

Should a LOCA occur with one recirculation loop not in operation, the core flow coastdown and resultant core response may not be bounded by the LOCA analyses. Therefore, only a limited time is allowed to restore the inoperable loop to operating status.

Alternatively, if the single loop requirements of the LCO are applied to operating limits and RPS setpoints, as applicable, operation with only one recirculation loop would satisfy the requirements of the LCO and the initial conditions of the accident sequence.

The 6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> Completion Time is based on the low probability of an accident occurring during this time period, on a reasonable time to complete the Required Action (i.e., reset the applicable limits or setpoints for single recirculation loop operation), and on frequent core monitoring by operators allowing abrupt changes in core flow conditions to be quickly detected.

(continued)

Brunswick Unit 1 B 3.4.1-4 Brunwic Uni 1 3.41-4Revision No.0 I

Reactor Steam Dome Pressure B 3.4.10 B 3.4 REACTOR COOLANT SYSTEM (RCS)

B 3.4.10 Reactor Steam Dome Pressure BASES BACKGROUND The reactor steam dome pressure is an 'assumed value in the determination of compliance with reactor pressure vessel overpressure protection criteria and is also an assumed initial condition of design basis accidents and transients.

APPLICABLE The reactor steam dome pressure of*: 1045 psig is an initial condition of SAFETY ANALYSES the vessel overpressure protection analysis of Reference 1. This analysis assumes an initial maximum reactor steam dome pressure and evaluates the response of the pressure relief system, primarily the safety/relief valves, during the limiting pressurization transient. The determination of compliance with the overpressure criteria is dependent on the initial reactor steam dome pressure; therefore, the limit on this pressure ensures that the assumptions of the overpressure protection analysis are conserved. Reference 2 also assumes an initial reactor steam dome pressure for the analyses of design basis accidents and transients used to determine the limits for fuel cladding integrity (see Bases for LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)') and 1 % fuel cladding plastic strain (see Bases for LCO 3.2. 1,, 'AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHG'R)I).

Reactor steam dome pressure satisfies the requirements of Criterion 2 of 10 CFR 50.36(c)(2)(ii) (Ref. 3).

LCO The specified reactor steam dome pressure limit of *ý 1045 psig ensures the plant is operated within the assumptions of the vessel overpressure protection analysis. Operation above the limit may result in a transient response more severe than analyzed.

APPLICABILITY In MODES 1 and 2, the reactor steam dome pressure is required to be less than or equal to the limit. In these MODES, the reactor may be generating. significant steam and events which may challenge the overpressure limits are possible.

(continued) anl L-Co 3.2.3) "LINEAl? HEACr GF-,ERA,4ripor4IoIJATE (LW61K) 5 Brunswick Unit 1 B 3.4.10-1 BrunwickUni 1 B3.4.0-1Revision No.g I

ECOS-Operating B 3.5.1 BASES BACKGROUND (continued)

The ADS (Ref. 4) consists of 7 of the 11 SRVs. It is designed to provide depressurization of the RCS during a small break LOCA if HPCI fails or is unable to maintain required water level in the RPV. ADS operation reduces the RPV pressure to within the operating pressure range of the low pressure ECCS subsystems so that these subsystems can provide coolant inventory makeup. Each of the SRVs used for automatic depressurization is equipped with one air accumulator and associated inlet check valves. The accumulator provides the pneumatic power to actuate the valves.

APPLICABLE The EGGS performance is evaluated for the entire spectrum of break SAFETY ANALYSES sizes for a postulated LOCA. The accidents for which ECOS operation is required are presented in References 5 and 6. The required analyses and assumptions are defined in Reference 7. The results of these analyses are also described in Reference 8.

This LCO helps to ensure that the following acceptance criteria for the EGGS, established by 10 CFR 50.46 (Ref. 9), will be met following a LOCA, assuming the worst case single active component failure in the EGGS:

a.

Maximum fuel element cladding temperature is:!* 22000F;

b.

Maximum cladding oxidation is!S 0.17 times the total cladding thickness before oxidation;

c.

Maximum hydrogen generation from a zirconium water reaction is 5 0.01 times the hypothetical amount that would be generated if all of the metal in the cladding surrounding the fuel, excluding the cladding surrounding the plenum volume, were to react;

d. 'The core is maintained in a coolable geometry; and long term cooling capability is maintained.

ring single failures are discussed in Referencel nt~

loop sug ion pipe! beak LOJFAfiu oo V(considereA the most evere Jei ure. Far a sm VDG Ao~r supprly Alure wgs combi ~ed witW o7L 0

n c r ed fcr HC 0Cic+ivc&1r-I' OLSSL~med in afx1

LOCA, nor-dyis Brunswick Unit 1 B 3.5.1-4 Brunwic Uni 1

3.51-4Revision No.g

ECCS-Operating B 1.5.1 BASES APPLICABLE out of sNrice assump~ *n to bound e single failu combinatio in a SAFETY ANALYSES /singi anals.

In dion to fail' g HPGI, one Spump and e ILPGI (continued) p p (due to th ower suppi ailure); two S valves wer assumed tof service

,ef. 10). Thi combination suits in an a wance for a single ADýS alve failure *no additio analysis an tresults in n

,accident__itigation cre being assu d for HPCI i anv LOCA a lysis.

The remaining OPERABLE ECOS subsystems provide the capability to adequately cool the core and prevent excessive fuel damage.

The EGOS satisfy Criterion 3 of 10 GFR 50.36(c)(2)(ii) (Ref. 11).

LCO Each EGCS injection/spray subsystem and six of seven ADS valves are required to be OPERABLE. The EGOS injection/spray subsystems are defined as the two CS subsystems, the two LPGI subsystems, and one HPGI System. The low pressure EGGS injection/spray subsystems are defined as the two OS subsystems and the two LPGI subsystems.

With less than the required number of ECOS subsystems OPERABLE, the potential exists that during a limiting design basis LOGA concurrent with the worst case single failure, the limits specified in Reference 9 could be exceeded. All EGGS subsystems must therefore be OPERABLE to satisfy the single failure criterion required by Reference 9.

LPGI subsystems may be considered OPERABLE during alignment and operation for decay heat removal when below the actual RHR shutdown cooling isolation pressure in MODE 3, if they are capable of being manually realigned (remote or local) to the LPGI mode and not otherwise inoperable. Alignment and operation for decay heat removal includes the period when the required RHR pump is not operating and the period when the system is being realigned to or from the RHR shutdown cooling mode.

At these low pressures and decay heat levels, a reduced complement of EGGS subsystems should provide the required core cooling, thereby allowing operation of RHR shutdown cooling when necessary.

APPLICABILITY All EGGS subsystems are required to be OPERABLE during MODES 1, 2, and 3, when there is considerable energy in the reactor core and core cooling would be required to prevent fuel damage in the event of a break in the primary system piping. In MODES 2 and 3, when reactor steam dome pressure is *ý 150 psig, ADS and HPOI are not required to be OPERABLE because the low pressure EGGS subsystems can provide sufficient flow below this pressure. EGGS requirements for MODES 4 and 5 are specified in LOO 3.5.2, "EGGS-Shutdown."'

(continued)

Brunswick Unit I B 3.5.1-5 Brunwic Uni 1

3.51-5Revision No.0

ECOS-Operating B 3.5.1 BASES SURVEILLANCE SR 3.5.1.12 (continued)

REQUIREMENTS TIME testing. This exception is allowed since the ECOS instrumentation response time is a small part of the ECCS RESPONSE TIME (e.g.,

sufficient margin exists in the emergency diesel generator start time when compared to the instrumentation response time) (Ref. 14).

ECCS RESPONSE TIME tests are conducted every 24 months. The 24 month Frequency is consistent with the Brunswick refueling cycle.

REFERENCES 1.

UFSAR, Section 6.3.2.2.3.

2.

3.

4.

5.

6.

7.

8.

9.

10.

UFSAR, Section 6.3.2.2.4.

UFSAR, Section 6.3.2.2.1.

UFSAR, Section 6.3.2.2.2.

UFSAR, Section 15.2.

UFSAR, Section 15.6.

10 CFR 50, Appendix K.

UFSAR, Section 6.3.3.

11.

12.

10 CFR 50.36(c)(2)(ii).

Memorandum from R.L. Baer (NRC) to V. Stello, Jr. (NRC),

Recommended Interim Revisions to LCOs for EGGS Components, December 1, 1975.

UFSAR, Section 6.3.3.7.

NEDO-32291 -A, System Analyses for the Elimination of Selected Response Time Testing Requirements, October 1995.

13.

14.

Brunswick Unit 1B351-7RvsoN.

B 3.5.1-17 Revision No. 0 1

Main Turbine Bypass System B 3.7.6 B 3.7 PLANT SYSTEMS B 3.7.6 Main Turbine Bypass System BASES BACKGROUND The Main Turbine Bypass System is designed to control steam pressure when reactor steam generation exceeds turbine requirements during unit startup, sudden load reduction, and cooldown. It allows excess steam flow from the reactor to the condenser without going through the turbine.

The bypass capacity of the system is 20.6% of the Nuclear Steam Supply System rated steam flow. Sudden load reductions within the capacity of the steam bypass can be accommodated without reactor scram. The Main Turbine Bypass System consists of four valves connected to the main steam lines between the main steam isolation valves and the turbine stop valves. The bypass valves are controlled by the pressure regulation function of the Turbine Electro, Hydraulic Control System, as discussed in the UFSAR, Section 7.7.1.4 (Ref. 1). The bypass valves are normally closed, and the pressure regulator controls the turbine control valves that direct all steam flow to the turbine. If the Speed Control System or load limit restricts steam flow to the turbine, the pressure regulator controls the system pressure by opening the bypass valves. When the bypass valves open, the steam flows through connecting piping and bypass valve pressure reducers to the condenser.

APPLICABLE SAFETY ANALYSES The Main Turbine Bypass System is assumed to function during the generator load rejection transient, the turbine trip transient, and the feedwater controller failure maximum demand transient, as described in the UFSAR, Section 15.2.1 (Ref. 2), Section 15.2.2 (Ref. 3),

and Section 15.1.2 (Ref. 4). Opening the bypass valves during the pressurization event mitigates the increase in reactor vessel pressure, which affects the MCPR during the event. An mnop rable Main T urbine Bypass System may result in APLHGR IGMCP penalties.

The Main Turbine Bypass System satisfies Criterion 3 of

, 4 dLG 10 CFR 50.36(c)(2)(ii) (Ref. 5).

(continued)

Brunswick Unit 1 B 3.7.6-1 Brunwic Uni 1

3.76-1Revision No. I

Main Turbine Bypass System a

u""

'J7.ý (and

+hee-L K G R. i i m'týs L C o 3 Z 3 B 3.7.6 CKJ RA're(LHCP P4 E PA W C XT G E r4l EAZ A,-Trl oKI R k-T E ( L HG P.

BASES (continued)

LCO The Main Turbine Bypass System is required to be OPERABLE to limit peak pressure in the main steam lines and maintain reactor pressure within acceptable limits during events that cause rapid pressurization, so that the Safety Limit MCPR is not exceeded. With the Main Turbine Bypass System inoperable, modifications to the APLHGR limits (LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)"),A~the MCPR limits (LCO 3.2.2"MNUMCICA POWER RAf 10 (MCPR)'ia-ybie applied to allow this LCO to be met.

The APLHGR AiiMCPliisfrteioealManTbneBas System are specified in the COLR. An OPERABLE Main Turbine Bypass System requires the minimum number of bypass valves, specified in the COLR, to open in response to increasing main steam line pressure. This response is within the assumptions of the applicable analysis Refs. 2, 3, and 4).

arALG APPLICABILITY The Main Turbine Bypass System is required to be OPERABLE at

>! 23% RTP to ensure that the fuel cladding integrity Safety Limit and the cladding 1 % plastic strain limit are not violated during the turbine generator load rejection transient. As discussed in the Bases for LCO 3.2.1,,.

LOG 3.2.2,Tsufficient margin to these limits exists at

< 23% RTV' Therefore, these requirements are only necessa when operating at or above this power level.

ERi I~

.2 ACTIONS A.1 If the Main Turbine Bypass System is inoperable (one or more bypass valves s specified in the COLR inoperable), and the APLHGR(:,M"ý o~% L GR MCP Rflimits for an inoperable Main Turbine Bypass System, as specified

ý~i~n thee COLR, are not applied, the assumptions of the design basis transient analysis may not be met. Under such circumstances, prompt action should be taken to restore the Main Turbine Bypass System to OPERABLE status or adjust the APLI-GRA0MICP I 5kimits accordingly.

The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time is reasonablA, based on the time to complete the Required Action and the low probability of an event occurring during this period requiring the Main Turbine Bypass System.

(continued)

Brunswick Unit 1 B 3.7.6-2 Revision No.

Main Turbine Bypass System B 3.7.6 BASES ACTIONS (continued)

B.1 If the Main Turbine Bypass System cannot be restored to OEA status and the APLHGR,40MCPRkJjmits for an inoperable Main Turbine Bypass System are not Applied, THERMAL POWER must be reduced to

< 23% RTP. As discussed in the Applicability section, operation at

< 23% RTP results in sufficient margin to the required limits, and the Main Turbine Bypass System is not required to protect fuel integrity during the applicable safety analyses transients. The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time is reasonable, based on operating experience, to reach the required unit conditions from full power conditions in an orderly manner and without challenging unit systems.

SURVEILLANCE REQUIREMENTS ISR 3.7.6.1 Cycling each main turbine bypass valve through one complete cycle of full travel demonstrates that the valves are mechanically OPERABLE and will function when required. The 31 day Frequency is based on manufacturer's recommendations (Ref. 6), is consistent with the procedural controls governing valve operation, and ensures correct valve positions. Operating experience has shown that these components usually pass the SR when performed at the 31 day Frequency.

Therefore, the Frequency is acceptable from a reliability standpoint.

S R 3.7.6.2 The Main Turbine Bypass System is required to actuate automatically to perform its design function. This SR demonstrates that, with the required system initiation signals, the valves will actuate to their required position.

The 24 month Frequency is based on the need to perform this Surveillance under the conditions that apply during a unit outage and because of the potential for an unplanned transient if the Surveillance were performed with the reactor at power.

(continued)

Brunswick Unit I B 3.7.6-3 Brunwic Uni I 3.76-3Revision No.0 I

Control Rod Testing-Operating B 3.10.7 BASES APPLICABLE SAFETY ANALYSES (continued)

As described in LCO 3.0.7, compliance with Special Operations LCOs is optional, and therefore, no criteria oflO CFR 50.36(c)(2)(ii) (Ref. 2) apply.

Special Operations LCOs provide flexibility to perform certain operations by appropriately modifying requirements of other LCOs. A discussion of the criteria satisfied for the other LCOs is provided in their respective Bases.

LCO As described in LCO 3.0.7, compliance with this Special Operations LCO is optional. Control rod testing may be performed in compliance with the prescribed sequences of LCO 3.1.6, and during these tests, no exceptions to the requirements of LCO 3.1.6 are necessary. For testing performed with a sequence not in compliance with LCO 3.1.6, the requirements of LCO 3.1.6 may be suspended, provided additional administrative controls are placed on the test to ensure that the assumptions of the special safety analysis for the test sequence are satisfied. Assurances that the test sequence is followed can be provided by either programming the test sequence into the RWM, With conformance verified as specified in SR 3.3.2-1.8 and allowing the RWM to monitor control rod withdrawal and provide appropriate control rod blocks if necessary, or by verifying conformance to the approved test sequence by a second licensed operator or other qualified member of the technical staff. These controls are consistent with those normally applied to operation in the startup range as defined in the SRs and ACTIONS of LCO 3.3.2.1, "Control Rod Block Instrumentation."

APPLICABILITY Control rod testing, while in MODES 1 and 2, with THERMAL POWER greater than 8.75% RTP, is adequately controlled by the existing LCOs on power distribution limits and control rod block instrumentation. Control rod movement during these conditions is not restricted to prescribed sequences and can be performed within the constraints of LCO 3.2.1, "AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR).

LCO 3.2.2, "MINIMUM CRITICAL POWER RATIO (MCPR)," nd LCO 3.3.2.1. With THERMAL POWER less than or equal to 8.75% RTP, the provisions of this Special Operations LCO are necessary to perform special tests that are not in conformance with the prescribed sequences of LCO 3.1.6.

(continued')

,LCO 3.2.3) "L(NEAd 0-EAT C-ENIERAJIW.

RATE (u-H6K)

Brunswick Unit I B 3.10.7-2 Bruswik Uit B.107-2Revision No. (2 1