INITIAL SUBMITTAL OF THE WRITTEN EXAMINATION FOR THE D. C. COOK INITIAL EXAMINATION - FEBRUARY 2006

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~.._____.__~. _ _ _ ~ ~.

~~~~~~~

~~~~~~~

1. 001 01 I/RO/OK/NEW//OOOOOI 2.1.20/(4.3 /4.2)//w3 Rod Control was in AUTO with Unit 1 power at 79% when MPC-253, Turbine~lmpulse Pressure Channel 1, failed low. The crew determined that a Turbine Runback was NOT in progress and placed rod control in Manual.

Which ONE of the following actions are required to Restore Equilibrium Conditions in accordance with 01 -0HP-4022-012-003. Continuous Control Bank Movement?

A. Initiate boration.

B* Reduce Turbine Load.

C. Insert Control Rods D. Initiate dilution.

ANSWER: B - Per 01-OHP-4022-012-003, Continuous Control Bank Movement, a reduction in steam demand is the prefered method to restore Tave to Tref. The failure of MPC-253 would have caused the control Rods to Insert (Tref lowered).

A - Incorrect - Rods inserted and Tave would be low for the current power level.

C - Incorrect - Rods inserted and Tave would be low for the current power level.

D - Incorrect - The procedure directs a reduction of Turbine load or a withdrawal of the control rods.

~~~~

~~~~~

~

~~~~~

~

~~~~~~~

~

REFERENCE:

01 -0HP-4022-012-003, Continuous Control Bank Movement, Step 3 LESSON PLANIOBJ: RO-C-AOP-7 I #5 KA - 000001 2.1.20 Continuous Rod Withdrawal Conduct of Operations Ability to execute procedure steps.

ROlSROValue- (4.314.2) CFR-41.10143.5145.12 212012006 Page 1 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

2. 002 OOl/RO/OWDIRECT-INPO/GINNA 2004-27278/000003 AAl.02K3.6

~~

I 3.4)//w2

~..~

During a power accension, with reactor power at 48%, control Bank C - Group 1 rod B-8 drops. Prior to the drop it was at 230 steps. While restoring the rod, control rod urgent failure alarm occurs.

Which one of the following explains why the alarm actuated?

A. All other Bank C - Group 1 rod lift coil disconnect switches are open.

B? All Bank C - Group 2 rod lift coil disconnect switches are open.

C. The step counter of the pulse to analog (P/A) converter was not reset to 0, D. Group C rod moving with group D rods withdrawn.

ANSWER: B - Since the dropped rod is completely inserted, the lift coil disconnect switches for all operable rods within the affected bank are opened. An Urgent failure will occur when the misaligned rod begins to move. This is caused by the non-movement of the group without the misaligned rod.

A - Incorrect - While all other Bank C Group 1 rods lift coils deenergized, the Alarm is generated from the failure of Group 2 movement (System monitors current through the lift coils - Since Bank C group 1 rod 8-8 still has current the alarm is from group 2)

C - Incorrect - While the P/A Converter is reset during rod recovery, failure to do so would not cause an urgent failure.

D - Incorrect - Group C is moved in the bank select mode. This would not cause an urgent failure alarm.

~~~~~~

~~~

~

~~~~~~

~~~~~~

~.

~~.~

REFERENCE:

02-OHP-4024.210, Annunciator #210 Response: Flux Rod, Drop 26 Rod Control Urgent Failure, RO-C-AOP-6, Abnormal Operating Procedures - Day 6 pg.

56 LESSON PLAN/OBJ: RO-C-AOP-6/#AOP 6.20, RO-C-01200 / #4 KA - 000003 AA1.02 Dropped Control Rod Ability to operate and/or monitor the following as they apply to the Dropped Control Rod:

Controls and components necessary to recover rod ROlSRO Value - (3.6 13.4) CFR - 41.7 145.5 145.6 SOURCE: INPO # 27278 Ginna 1 - 4/27/2004 Original Quest. KA - 000003AK2.05 2/20/2006 Page 2 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

3.

.~ 003 ~3/RO/OK/DIRECT/BANKO~AOPC~1-1/000005 AKI.02/(31313.9)//F/2

~~~

~

~~~~

~~

During power escalation of Unit 2, a single rod in Control Bank D is misaligned.

Procedure OHP 4022.012.005, Dropped Or Misaligned Rod is being performed. A CAUTION prior to step #2 requires that any required power reductions must be accomplished using boration rather than control rods.

The purpose of this requirement is to prevent:

A. Moving the control rods until a failure analysis can be initiated.

B. Another rod failure until the cause of the initial failure can be identified.

C!' Exaggerating any existing flux tilts.

D. Exceeding Rod Insertion Limits during the power reduction.

ANSWER: C - With a single misaligned rod, flux tilts could develop across the core.

Further movement of the rods could cause a greater tilt and subsequent oscillations.

A - Incorrect - Failure analysis is not the reason for using Boron B - Incorrect - While this may be prudent it is not the reason for the caution.

D - Incorrect - Insertion Limits wouldn't be exceeded with 1 rod misaligned.

~

~

~

~~

~

~~~

~~

~~~

~

REFERENCE:

1 (2)-OHP 4022.012.005 LESSON PLAN/OBJ: RO-C-AOP-6/#21; RQ-C-2514/#4 KA - 000005 AK1.02 Inoperable/Stuck Control Rod Knowledge of the operational implications of the following concepts as they apply to Inoperable/Stuck Control Rod:

Flux tilt RO/SRO Value - (3.1 / 3.9) CFR - 41.8 / 41.1 0 / 45.3 Original question Source: Bank 01 AOPC621-1 Original KA APE 003 AA1.05 (4.1/4.1)

ORIGINATION DATE: 10/24/00 REVISION DATE: 10/16/2003 EXAM/QUIZZES: R021AOP3; RQ2526CWS; R022EOP4A; R022EOP4B 2/20/2006 Page 3 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~~~ 4.

~~ 004 003/RO/OWMODIFIED/C00K 2002 NRS 027/000007 EK3:0 144.0 /4.6)//H13

~~~

The following plant conditions exist:

- A Reactor trip from 100% power has occurred on Unit 2. OHP-4023-E-0, Reactor Trip Or Safety Injection, is being implemented.

- Containment pressure is 0.6 psig and stable.

- SG NR Levels are offscale low.

- RCS pressure is 21 50 psig and lowering.

- Control Rod H-8 is indicating 32 steps.

- All systems responded normally to actuation signals.

Which ONE of the following actions should be taken?

A. Transition to 02-OHP-4023-ES-0-1, Reactor Trip Response, and initiate boration for a stuck rod.

BY Transition to 02-OHP-4023-ES-0-1, Reactor Trip Response. Rod H-8 condition is expected so boration is not required for a stuck rod.

C. Initiate Safety Injection and continue with 02-OHP-4023-E-0, Reactor Trip Or Safety Injection, as pressurizer pressure is too low.

D. Initiate Safety Injection and continue with 02-OHP-4023-E-0, Reactor Trip Or Safety Injection, as Steam Generator levels are too low.

~~~~

~

~.

~

~~~~~~~~~~~

~.

~

~~~~~

~~~

. ~

~~~~~~~~~~

ANSWER: B - Unit 2 Rod H-8 is required to be less than 35 steps.

All other rods should be less than 10 steps. Plant conditions do not require a Safety Injection.

A - Incorrect - Rod H-8 is expected to be less than 10 steps on Unit 1.

C - Incorrect - RCS pressure will decrease post trip it is still above the SI setpoint.

D - Incorrect - SG levels will decrease to offscale low post trip. AFW will recover levels.

2/20/2006 Page 4 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test Modified to Unit 2 which allows rod H-8 to indicate up to 35 steps. This changed answer B to correct Answer.

REFERENCE:

02-OHP-4023-E-0, Reactor Trip Or Safety Injection; 02-OHP-4023-ES-0-1, Reactor Trip Response LESSON PLAN/OBJ: RO-C-EOP03 / #24 KA - 000007 EK3.01 Reactor Trip - Stabilization Knowledge of the reasons for the following responses as they apply to the reactor trip:

Actions contained in EOP for reactor trip RO/SRO Value - (4.0 / 4.6) CFR - 41.5 / 41.10 / 45.6 / 45.13 SOURCE: COOK 2002 NRC #027 (RO#N/A, SRO#25)

Original KA : 000007 - 2.4.48 Reactor Trip

- Emergency Procedures/Plan

- Ability to interpret control room indications to verify the status and operation of system, and understand how operator actions and directives affect plant and system conditions.

NOTE: Unit difference KA 2.2.3 (3.3 / 3.1) - If on Unit 1, correct answer would be "Transition to 01 -0HP-4023-ES-0-1. Rod H-8 condition is NOT expected so boration is required for a stuck rod."

2/20/2006 Page 5 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

5. 005 002/RO/OK/DIRECTIRO23 AUDIT 037-4/000008 AK2.03/(2.5 / 2.4)//F/3

~~~~~

~~~~~

Which ONE of the following correctly describes the plant response if the listed instrument fails HIGH while in the LTOP mode?

A. RVLlS Wide Range pressure instrument NPS-110 will cause PORV NRV-153 to OPEN.

B. RVLlS Wide Range pressure instrument NPS-110 will cause PORV NRV-152 to OPEN.

C? Wide Range RCS pressure instrument NPS-121 will cause PORV NRV-153 to OPEN.

D. Wide Range RCS pressure instrument NPS-12 OPEN.

will cause PORV NRV-152 to

~

~ ~-

~~

~~

ANSWER: C - Pressurizer PORV NRV-153 will open if NPS-121 fails open:

A - Incorrect - RVLlS WR pressure does not feed the PRZ Porvs.

B - Incorrect - RVLlS WR pressure does not feed the PRZ Porvs.

D - Incorrect - WR RCS pressure NPS-122 opens PORV NRV-152 Changed Stem & distractors slightly

REFERENCE:

SOD-00202-001 Rev 1 LESSON PLAN/OBJ: RO-C-00202/#22; KA - 000008 AK2.03 Pressurizer (PZR) Vapor Space Accident (Relief Valve Stuck Open)

Knowledge of the interrelations between the Pressurizer Vapor Space Accident and the following:

Controllers and positioners RO/SRO Value - (2.5 / 2.4) CFR - 41.7 / 45.7 Original Question Source: R023 Audit 037-4 (RO#036 /SRO#036) from #1022.doc 1 Original KA - APE 008 AA206 (3.3/3.6) 2/20/2006 Page 6 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~. 6. 006. OOl/RO/OWDIRECT-INPO/S_ALEM 2003 - 24053/000009 EK2.03K3.0 /3.3)//F13

~~.

~~

Which of the following is the basis for establishing / maintaining S/G Narrow Range level between 27%-50% (non-adverse containment) for small or intermediate LOCA's?

A. Maintains a static head of water to reduce any existing S/G tube leakage.

BY Ensures adequate feed flow or S/G inventory to ensure a secondary heat sink.

C. A RCP may have to be started if 02-OHP-4023-FR-C.l is entered later in the event.

D. Maintain the water level above the top of the U-tubes to prevent depressurizing S/G.

~. ~. _ _ _ _ ~ ~

~.

~.~

~~

~

ANSWER: 6 - E-1 Basis Document states the purpose of establishing 27% level is to ensure adequate feed flow or S/G inventory to maintain a secondary heat sink for small or intermediate size LOCAs and secondary break accidents. 50% is the S/G narrow range upper control band limit.

A - Incorrect - because it is the basis for S/G level /feed flow for a LARGE break LOCA.

C - Incorrect - The RCP is started in FR-C.1 even if level is not available D - Incorrect - This is the reason for maintaining level during a tube rupture.

REFERENCE:

12-OHP-4023-ES-1.2 Step 9 pg. 25 LESSON PLAN/OBJ: RO-C-EOP09/#36 KA - 000009 EK2.03 Small Break LOCA Knowledge of the interrelations between the small break LOCA and the following:

SIGs RO/SRO Value - (3.0 / 3.3) CFR - 41.7 / 45.7 SOURCE: INPO # 24053 Salem Unit 1 - 5/5/2003 Original Quest. KA - 000009.K2.03 2/20/2006 Page 7 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

7.

~ 007

~~~~~~~~~

00I/RO/O~~ODIFIED/CO~K 2004-27~~9/000015 AA2.09/(&4 / 3.5)//H/3 ~-

~~~~

Unit 2 Reactor Startup is in progress with Reactor Power at 2% and rising.

The following conditions exist:

- RCP No. 3 Lower Bearing water temperature is 208°F and stable

- RCP No. 3 Motor Bearing temperature is 187°F and stable.

- RCP No. 3 Seal Leakoff temperature is 179°F and stable.

- RCP No. 3 Motor Temperature is 148°C and rising.

- Annunciator 107 Drop 40, RCP Motor Overheated - LIT Which ONE of the following operator actions MUST be taken based upon these conditions?

A. Do NOT trip the reactor. Trip the No. 3 RCP. Power must be maintained less than 5% (Mode 2).

No. 3 RCP within 8 Hours.

BY Initiate reactor shutdown per 02 OHP 4021.001.003, Power Reduction and trip the C. Manually trip the reactor, Enter 02 OHP 4023.E 0, Reactor Trip or Safety Injection, perform immediate actions, then trip the No. 3 RCP.

D. Immediately Trip the No. 3 RCP. Initiate reactor shutdown per 02 OHP 4021.001.003, Power Reduction and be in Mode 3 within 6 Hours.

ANSWER: B -The RCP Motor Temperature has exceeded the limit of 145%. This requires the reactor to be shutdown and the RCP tripped within 8 Hours.

A - Incorrect - RCP Lower bearing temperature is elevated but has not exceeded the trip setpoint of 225°F. (Motor Bearing Temperature is limited to 200°F). Additionally, the Plant is not analyzed/licensed to operate with less than 4 RCPs. Tech Specs require Mode 3 within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> with less than 4 RCP loops.

C - Incorrect - RCP Lower bearing temperature is elevated but has not exceeded the trip setpoint of 225°F. (Motor Bearing Temperature is limited to 200°F). An Immediate trip is not required for the RCP Motor Temperature.

D - Incorrect - RCP Lower bearing temperature is elevated but has not exceeded the trip setpoint of 225°F. (Motor Bearing Temperature is limited to 200°F). An Immediate trip is not required for the RCP Motor Temperature. The Plant is not analyzedhcensed to operate with less than 4 RCPs.

~

~~~~~~~

~~~~~~~~~~

~

~~~~~~

~

~~~~~~~~

~~

~

~

2/20/2006 Page 8 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test Modified Question to Add Motor Temperature and Alarm. Changed Lower Bearing temperature to elevated status (but < trip). Changed Distractors A & D to include power requirements. Answer Changed from C to B.

REFERENCE:

02-OHP-4022-002-001, Malfunction Of A Reactor Coolant Pump step

10.

LESSON PLAN/OBJ: RO-C-AOP-11 / #19 KA - 00001 5 AA2.09 017 Reactor Coolant Pump (RCP) Malfunctions Ability to determine and interpret the following as they apply to the Reactor Coolant Pump Malfunctions:

When to secure RCPs on high stator temperatures RO/SRO Value - (3.4 / 3.5) CFR - 43.5 / 45.13 SOURCE: INPO # 27639 Cook 1 - 4/19/2004 Original Quest. KA - 00001 5 AK1.02 2/20/2006 Page 9 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

8. 008 002/RO/OWDIRECT/01003C001313!~0022 AA2.02K3.2 / 3.7)/@/3

~

r-- ~With~i2O~gpm letdown in service and blender controls in automatic on Unit 1, the VCT I

level transmitter QLC-452 fails to 100%.

I With NO operator action, actual VCT level will:

A. lower to 2.5% and RWST swapover will occur automatically.

B. lower to 14% and stabilize due to auto makeup flow.

CY lower to zero and eventually result in loss of CCP suction.

D. rise to 87% and stabilize due to full divert flow.

ANSWER: C I ~ A Failure of QLC-452-high will cause Letdown to divert to the HUT. Auto VCT makeup will attempt to control VCT level between 14 and 24% (Makeup will not keep up with 120 gpm letdown). Eventually the VCT level will lower to the RWST switchover setpoint. With 452 failed high, the coincidence for switchover will not be made up and level will continue lowering to 0%. At this time suction will be lost to the charging pumps and they will trip.

A - Incorrect - The auto swapover will not occur with QLC-452 failed high.

B - Incorrect - VCT Makeup is not sufficient to replace the 120 gpm lost through diversion to the HUT.

D - Incorrect - The level will lower as the letdown is diverted to the HUT. If QLC-451 failed low this would be the correct response.

REFERENCE:

RO-C-AOP-6 Abnormal Operating Procedures - Day 6 pg. 39 lp~..~---

. ~~~~

~~~

~

LESSON PLAN/OBJ: RO-C-AOP-6/#AOP-6.15, RO-C-00300/#12, 14,19 KA - 000022 AA2.02 Loss of Reactor Coolant Makeup Ability to determine and interpret the following as they apply to the Loss of Reactor Coolant Pump Makeup:

Charging pump problems RO/SRO Value - (3.2 / 3.7) CFR - 43.5 / 45.13 Original Question Source: 01 003COO13-3 Original KA: SYS 004 A.03 (3.3/3.3)

EXAM/QUIZZES: R921517; R015 AUDIT EXAMNRC(286); R020SR03; SRO Cert 2

& 3; RQ2703V; RQ2703E; RQ2703B 2/20/2006 Page 10 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~~~ 9.

~ 009

~~~~~~

00I/RO/OWDIRECT-INPO/SEAB~OOK.200~-24615/000025 2.2.23/(2.6 l~ 3~.8)//H/2.

~

The following Unit 2 conditions exist:

- The unit is in MODE 5 with the RCS intact.

- Both trains of RHR are available, with the 2 West RHR train is in operation.

- Both PORVs are lined up for LTOP mode of operation.

- The West CCP and Both SI pumps are Tagged out.

Due to indication of cavitation on 2 West RHR Pump, the crew enters 02-OHP-4022-017-001, Loss of RHR Cooling.

Per the procedure, the crew isolates both trains of RHR by placing both RHR pumps in Pull-to-Lock and closes RHR suction valves IMO-128 and ICM-129.

How does this action affect the Technical Specification operability of Overpressure Protection Systems?

A? Technical Specification requirements are met. Both PORVs are available for overpressure control.

be available for overpressure protection.

Isolated/ Tagged -Out.

B. Technical Specification requirements are NOT met. The RHR suction relief must C. Technical Specification requirements are NOT met. The Charging Pump must be D. Technical Specification requirements are met. Isolating RHR suction valves does ANSWER: A~ - Tech. Spec requirements are met. Both PORVs are available for overpressure control. T.S. 3.4.12 requires 2 overpressure protection flowpaths, whether both PORVs a PORV and RHR suction relief. Closing the RHR suction valves isolates the RMR suction reliefs, but the PORVs are still available.

B - Incorrect - The RHR suction Relief is not required since 2 PORVs are available and only 1 CCP is available. (True if both CCPs available)

C - Incorrect - 1 CCP may be available with 2 PORVs.

D - Incorrect - The Suction Reliefs are downstream of the RCS to RHR isolation Valves.

not affect operability of the RHR suction reliefs.

~~

~~~

~

~

~~~

~ ~-

~~~

~~~~

~~~

~

~~~~~~

2/20/2006 Page 11 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

Technical Specifications 3.4.1 2 LESSON PLAN/OBJ: RO-C-O1700/#13 KA - 000025 2.2.23 Loss of Residual Heat Removal System (RHRS)

Equipment Control Ability to track limiting conditions for operations.

RO/SRO Value - (2.6 / 3.8) CFR - 43.2 / 45.13 SOURCE: INPO # 2461 5 Seabrook 1 - 5/30/2003 Original Quest. KA - 025.2.1.12 2/20/2006 Page 12 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

10.

~~~~~

010 002/RO/OWDIRECT/COOK

~

200~1 Q#65/000026 AK3.01K3.2 / 3.5)/COOWH/2 The following plant conditions exist:

- RCS pressure is 1600 psig and lowering

- Pressurizer is empty

- Containment pressure is stable at 1.5 psig You have been directed to close 2-WMO-734, ESW outlet valve for CCW HX 2 East.

What actions; if any, must be taken to close the valve?

A. The valve control switch must be put in pull-to-stop and must be closed locally.

control switch.

BY When the valve reaches its preset position you can close the valve using the C. No action is necessary, the valve has already been closed by an automatic signal.

D. SI must be reset to close the valve using the control switch.

ANSWER: B - Three-position control switches in control room CLOSE - Closes valve PULL TO STOP - No longer needed since modified to hold-to-operate OPEN - Opens valve The listed plant conditions indicate an SI so the valve will automatically move to preset intermediate position on receipt of an SI signal corresponding to an approximate flow rate of 5000 gpm. The valve can be closed by holding the control switch to close after it has reached its throttle position.

A - Incorrect - The valve can be closed with the hand switch after it has reached throttle position.

C - Incorrect - The valve will position open to a preset position.

D - Incorrect - The valve will NOT close until it reaches it throttle position.

~~

~~~

~

~~~

~

~~~~

~~~~~~

~.

~~~~~

~

~~~~~~

2/20/2006 Page 13 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test Removed SG level from Stem. Changed from "told" to directed. Changed "position" switch to "control" switch. Changed distractor A to Pull-to-Stop vs. lock and "locally" vs Manually. Distractor D changed to include After SI reset.

REFERENCE:

RO-C-01900, Essential Service Water System pg. 22 LESSON PLAN/OBJ: RO-C-O1900/#11 KA - 000026 AK3.01 Loss of Component Cooling Water (CCW)

Knowledge of the reasons for the following responses as they apply to the Loss of Component Cooling Water:

The conditions that will initiate the automatic opening and closing of the SWS isolation valves to the CCW/nuclear service water coolers RO/SRO Value - (3.2 / 3.5) CFR - 41.5 141.1 0 1 45.6 / 45.1 3 SOURCE: INPO # 19517 Cook 1 - 5/21/2001 Original Quest. KA - 000026.K3.01 2/20/2006 Page 14 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test 1 1. 01 I 002/RO,OWDIRIiCI'-INPO/HKM'[, 2002. 21179/00(Hl?7,\\K1.(13/(? $, 2 Yi//Il/3 Assume that the Pressurizer master pressure controller output were failed AS IS just before a large, rapid secondary load rejection.

Which of the following would occur naturally in the Pressurizer to limit the magnitude of tne resulting pressure transient on the primary system?

A. An outsurge causes the steam space to expand in the PRZ. This allows some liquic B. An insurge of hotter water heats the Pzr. More liquid then flashes to steam helping C!' An insurge of cooler water compresses the steam space in the Pzr. Steam is condensed to water helping to limit the overall pressure increase in the RCS.

D. An outsurge cools the Pzr. This allows some steam to condense to water and limits ANSWER: C - A secondary load rejection will cause RCS temperature to rise.

Pressurizer pressure will initially follow the level trend. As Tavg initially increases, level will increase causing an insurge which causes pressure to rise. Since the water from the insurge is cooler than the pressurizer liquid, steam is condensed to water helping to limit the overall pressure increase in the RCS.

A - Incorrect - The load rejection will cause an insurge. Plausible since this is the response for a secondary load increase.

B - Incorrect - The insurge liquid from the RCs hot leg is still significantly cooler than the Pressurizer liquid temperature.

D - Incorrect - The load rejection will cause an insurge. Plausible since an outsurge would remove some energy from the pressurizer.

to flash to steam and limits the resulting pressure drop in the RCS.

to limit the resulting pressure drop in the RCS.

the resulting pressure increase in the RCS.

~~~

~

~~~

~~~~

~

~

~

~

~

~

~~~

~

~~~

~~~~~

~

REFERENCE:

RO-C-GF26 OBSERVING REACTOR BEHAVIOR DURING REACTOR TRANSIENTS pg. 6-12 LESSON PLAN/OBJ: RO-C-GF26/#1 KA - 000027 AK1.03 Pressurizer Pressure Control (PZR PCS) Malfunction Knowledge of the operational implications of the following concepts as they apply to Pressurizer Pressure Control Malfunctions:

Latent heat of vaporization/condensation RO/SRO Vatue - (2.6 / 2.9) CFR - 41.8 / 41.10 / 45.3 SOURCE: INPO # 21479 Braidwood 1 - 7/17/2002 Original Quest. KA - 027.akl.03 2/20/2006 Page 15 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

-~

12.

~~~

012

~~~ 001/RO/OWNEW//000029

.~

~~

~~~~~

EAl.OY(3.7

~~~~

/3.6)//w3

~~~~

~~~~~

~~~

~

The following plant conditions exist:

- Unit 1 has experienced an Anticipated Transient Without Scram (ATWS), and has implemented 01 -0HP-4023-FR-S.l, Response to Nuclear Power Generation/ATWS. QMO-410, emergency boration to CCP suction valve will NOT OPEN.

- SI has been initiated.

Which one of the following identifies the correct actions and reason to satisfy 01 -0HP-4023-FR-S.l Step 5, Initiate Emergency Boration Of RCS?

A. 1) Open at least one CCP suction from RWST valve: 1-IMO-910 -OR-1-IMO-911

2) Close at least one CCP suction from VCTvalve: 1-QMO-451 -OR-1-QMO-452
3) Maximize charging flow.
4) Verify letdown flow established.

This ensures at least 120 gpm of Borated RWST water is injected through the Normal Charging flowpath.

6. 1) Open both boration valves: 1-QRV-400 -AND-1-QRV-421
2) Start both boric acid transfer pumps in FAST speed.

This ensures at least 36 gpm of Borated BAST water is injected through the Normal Charging flowpath.

C. 1) Open at least one of the boration valves: 1 -QRV-400 -OR-1 -QRV-421

2) Start both boric acid transfer pumps in FAST speed.

This ensures at least 36 gpm of Borated BAST water is injected through the Normal Charging flowpath.

D!' 1.) Verify Pressurizer Pressure is <2335 psig.

This ensures at least 120 gpm of Borated RWST water is injected through the BIT injection lines.

ANSWER: D - On a Safety Injection, Both CCPs start, IMO-910~&

91 1 Open, and-the BIT Injection Lines Open providing RWST injection to the RCS. Step 5b RNO has the Operator go to step 5c which checks Pressurizer pressure if a SI is actuated.

A - Incorrect - The Normal Charging flowpath will isolate on a SI. Plausible since this is an acceptable flowpath if SI is not actuated.

B - Incorrect - The Normal Charging flowpath will isolate on a SI. Plausible since this is an acceptable flowpath if SI is not actuated.

C - Incorrect - The Normal Charging flowpath will isolate on a SI and BOTH QRV-400 and 421 are required to be open. Plausible since this is similar to the flowpath if SI is not actuated. The option for aligning the CCPs to the RWST require only 1 of the valves to be opened.

..~~

~~~~~~

~

~~~

~~~

~~~~

~

~

~

2/20/2006 Page 16 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

01 -0HP-4023-FR-S.1 Response to Nuclear Power GeneratiodATWS Step 5 LESSON PLAN/OBJ: RO-C-EOP04/#15 KA - 000029 EA1.05 Anticipated Transient Without Scram (ATWS)

Ability to operate and/or monitor the following as they apply to a ATWS:

BIT outlet valve switches RO/SRO Value - (3.7 / 3.6) CFR - 41.7 / 45.5 145.6 2/20/2006 Page 17 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~~~

13.

~

013 006/RO/OK/DIRECT/AOP1CAOP12.9-3/000036 AK3.03/(3.7 /-4. I)//F/3..

~~~~~~~~

~~

The following plant conditions exist:

- Ann. 205, Drop 28, SFP Temp High - LIT.

- South (U2) SFP pump out for maintenance.

- South SFP Hx is available for use.

- North SFP Hx shell develops a large leak requiring Hx to be isolated.

Procedure 12-OHP-4022-018-001, Loss of Spent Fuel Pit Cooling allows cross-tie of the North SFP Pump through a 3" line to the South SFP Hx.

This action will.

A. maintain the SFP temperature at normal conditions until repairs are made.

E. prevent the SFP from boiling, but result in operation at elevated temperature.

C. prevent the SFP from boiling if used in conjunction with 125 gpm makeup.

D?, extend the time to SFP boiling to allow time for repair of system.

~~~~

~

~~~~~

~~~~~

~~~~~~

~~~~

~~~~

~

~~

~

~~~

~~~~~

~~

~~~

~

~~~~

~~

ANSWER: D - Crosstieing the North Pump through the 3" line to the South HX will delay the time to boiling but will not prevent boiling unless makeup flow of 175 gpm is also used.

A - Incorrect - Temperatures will rise to the boiling point.

B - Incorrect - Temperatures will rise to the boiling point.

C - Incorrect - Temperatures will rise to the boiling point unless makeup flow of 175 gpm is also used.

REFERENCE:

12-OHP-4022-018-001, Loss of Spent Fuel Pit Cooling Step 9 & Note LESSON PLAN/OBJ: RO-C-AOPl2/AOP12.9 KA - 000036 AK3.03 Fuel Handling Incidents Knowledge of the reasons for the following responses as they apply to the Fuel Handling Incidents:

Guidance contained in EOP for fuel handling incident ROISRO Value - (3.7 14.1) CFR - 41.5 / 41.10 / 45.6 145.13 SOURCE: Master Bank AOPlCAOPl2.9-3 212012006 Page 18 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~~~

14. 014

~ 0lO/RO/OK/MODIFIED/COOK04-010/000038

~

~

~~

~....

EK1.02/(3.2

~. /3.5)//w4

-~

~~~

~

~~~~

~~~

During power operation, SG tube leakage was detected and estimated at 150 gpm when RCS pressure was 2200 psig and SG pressure was 800 psig. The plant was shutdown and a cooldown initiated.

Which ONE of the following is the approximate current leak rate if RCS pressure is 1700 psig and SG pressure is 1000 psig? Assume the break size has not changed.

1

~

A. Approximately 75 gpm B* Approximately 107 gpm C. Approximately 21 2 gpm D. equal to the initial leak rate of 150 gpm ANSWER: B - Break flow is Proportional to the Square Root of the Pressure Differential.

~

~~~~~~~~~~~~~~

~

~~~~~~~~~~~~~~

~

~~

~~~~~~~~~~~

~

~~~~~

~

Flow1.t = 4

)

FLOW = ~(1700-1000)/(2200-800)x150=.70~150~

107 Flow is -70% of initial or 107 gpm A - Incorrect - Differential pressure is 1/2 of original but break flow should be proportional to the square root of DP.

C - Incorrect - This swaps the order of the pressures 1400/700 = 2 and the square root of 2 is 1.41.

D - Incorrect - This is original value. The DP changed and so does break flow.

2/20/2006 Page 19 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test Modified from Cook 2004 NRC Exam #10 - Changed Question Stem from 50 gpm to 150 gpm. Also changed Distracters accordingly and removed percentages.

REFERENCE:

RO-C-EOP05, SI Termination, ECCS Flow Reduction, and SI Reinitiation and Actuation; RO-C-GF27, Sensors and Detectors LESSON PLAN/OBJ: RO-C-GF27 / #10 KA - 000038 EK1.02 Steam Generator Tube Rupture (SGTR)

Knowledge of the operational implications of the following concepts as they apply to the SGTR:

Leak rate vs. pressure drop RO/SRO Value - (3.2 / 3.5) CFR - 41.8 / 41.10 / 45.3 SOURCE:2004 NRC Exam Q#10 Cook 1 - 4/29/2004 Original Quest. KA - 000037 AK1.02 Steam Generator (S/G) Tube Leak Knowledge of the operational implications of the following concepts as they apply to Steam Generator Tube Leak:

Leak rate vs. pressure drop RO-3.5 SRO-3.9 2/20/2006 Page 20 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test 1 5. 01 5 002/RO/OK/MODIFIED/BEAVERVAL

~~~~~

2002/000054 AAI

~.04/(4.4

~

~~

/4.5)//H/2

~~~~~~

~~

~~~

~

The following plant conditions exist:

- A loss of all FW and AFW has occurred.

- The operating crew has entered FR-H.l, Loss Of Secondary Heat Sink.

- The RO identifies that the East CCP has tripped and that the West CCP will NOT Start.

Which one of the following describes the consequences of the CCP failures?

A? RCS Bleed and Feed cooling must be established immediately to ensure sufficient SI flow.

B. A Red Path on the Core Cooling Critical Safety Function will develop due to loss of RCS inventory with no available makeup.

C. The RCS will not depressurize quickly enough to ensure sufficient SI flow to provide RCS heat removal, so other RCS openings will have to be established.

D. RCS Bleed and Feed cooling must NOT be initiated and secondary depressurization to inject condensate pump flow must be immediately initiated.

ANSWER: A - Step 2 of OHP-4023-FR-H.l requires that Bleed and Feed be initiated immediately initiated if the CCPs are not available. If it is known that no CCP is available for bleed and feed, then all RCPs are stopped and bleed and feed is initiated immediately. The RCS will have to depressurize below the shutoff head of the SI pumps before any ECCS injection will occur, so the bleed and feed must be initiated prior to the loss of heat removal capability of the SGs.

~

~

~~~~~~~~

~

~~~~~~

~.

~~~~~

~~

~~~~~~~~~~~

B - Incorrect. Although a red condition on Core Cooling may eventually occur, there is available makeup with SI.

C - Incorrect. Bleed and Feed is started early enough so that the RCS can depressurize far enough to allow SI injection. Additional Openings are used if all PORVs are NOT available.

D -Incorrect. Action to align condensate pumps may still be taken, but not as a contingency to Bleed and Feed.

2/20/2006 Page 21 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test Modified BV question Stem from loss of PORV to loss of CCP. Changed Answer &

Distracters.

REFERENCE:

12-OHP-4023-FR-H.l Loss of Heat Sink Background Step 2.

OHP-4023-FR-H.l Loss of Heat Sink Step 2.

LESSON PLAN/OBJ: RO-C-EOP11/#7 KA - 000054 AA1.04 Loss of Main Feedwater (MFW)

Ability to operate and/or monitor the following as they apply to the Loss of Main Feedwater (MFW):

HPI, under total feedwater loss conditions RO/SRO Value - (4.4 / 4.5) CFR - 41.7 / 45.5 / 45.6 SOURCE: INPO # 25008 Beaver Valley 1 - 12/1/2002 Original Quest. KA - E05.EK1.I 2/20/2006 Page 22 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

16. 016 ~ ~ ~ / R O / O W D I R E C T / ~ ~ E P P C ~ ~ ~ ~ - I / ~ ~ O O ~ ~

2.4.29/(2.6 /4.0)//~/2

~..

~~

~~

olant has exDerienced a Loss of All Offsite AC-and only the 2AB EDG is operating. 1

~~~~~

~

1 Due io the Loss of Power, the PPC is not available. What contingency action is taken to compensate for the unavailability of the PPC?

A. Emergency Response Data System (ERDS) is activated.

B. Safety Parameter Display System (SPDS) is transmitted to the NRC.

C?' PMP-2080-EPP-100 Data sheet 1, Technical Information sheet, is completed every 15 minutes.

D. PMP-2080-EPP-100 Data sheet 4, Plant Status sheet, is completed every 60 ANSWER: C - Upon loss of the PPC and/or EDR the PMP-2080-EPP-100 Data sheet 1, Technical Information sheet, is completed every 15 minutes and sent to applicable facilities.

A - Incorrect - ERDS is normally activated within 60 Minutes but will not be available if the PPC is not working.

B - Incorrect - SPDS will not be available if the PPC is not working.

D - Incorrect - This is the information sheet that is used for guidance when communicating with the NRC.

REFERENCE:

PMP-2080-EPP-100 Section 3.2.3.b.4 minutes.

~,.~~

~~

~~ ~ _ _ _ ~ ~ ~

~ ~

~

~

~~

~

LESSON PLAN/OBJ: ST-C-EP04/#3 KA - 000055 2.4.29 Loss of Offsite and Onsite Power (Station Blackout)

Emergency Procedures/Plan Knowledge of the emergency plan.

RO/SRO Value - (2.6 / 4.0) CFR - 43.5 / 45.1 1 Original Question Source: Bank 12EPPC0403-1 Original KA 2.4.40 (2.3/4.0)

EXAMIQUIZZES: RQ2603C; RQ2603D; RQ2603E; RQ2603A; RQ2603B; RQ2603C; RQ2603E; R022EPPRO; R022EPPSRO 2/20/2006 Page 23 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

17. 017

. ~ ~ ~ _ _ _ _ _

OOl/RO/OWDIRECT-INPOICOOK 2001 RT Q#46/000056 AKlO1/(3.7,/~4.2)NF/2~~~~~~

~

~

~~~~~~

Unit 2 was operating at 100% power when a reactor trip occurred due to a loss of offsite power. The operators completed the actions of 02-OHP-4023-ES-0.1, Reactor Trip Response, and have transitioned to 02-OHP-4023-ES-0.2, Natural Circulation Cooldown, where they are initiating a natural circulation cooldown.

At the onset of the natural circulation cooldown, which ONE of the following processes will remove the MOST heat from the Reactor Vessel HEAD?

A? All CRDM fans running.

B. Upper head bypass flow.

C. Heat losses to ambient.

D. The 25 F/hr natural circulation cooldown of the RCS.

ANSWER: A~ - CRDM fan operation results in a considerable amount of heat removal from the upper head region. The results from several tests at domestic and foreign plants indicate that the Control Rod Drive Mechanism (CRDM) cooling fans aid significantly in removing heat from the upper head area. At 600°F this will result in a cooldown rate of the upper head of approximately 21 "F/hr.

B - Incorrect - Analysis assumed for Cook Nuclear Plant results in this average cooldown rate of the upper head fluid to be about 10"F/hr when a 25"F/hr N/C cooldown rate of the bulk of the RCS is in progress.

C - Incorrect - Losses to ambient result in c1 "F/hr cooldown rate.

D - Incorrect - This cooling would come from upper head bypass flow which is about 10"F/hr when a 250F/hr N/C cooldown rate of the bulk of the RCS is in progress.

REFERENCE:

12-OHP 4023 ES-0.2 PSBD Step 5, RO-C-EOP03 Plant Trips, Diagnosing Accidents, Natural Circulation Cooldown, E-0 Series EOPs, and Background Information pg. 74-78

~

~

~~

~~~~

~~~~

~~

~

~

~~~~~~~~~~~

~~

~

~

~

~

~

~

~

~

~

~~~~~

~~~~

~~~~~

LESSON PLAN/OBJ: RO-C-EOPO3/#8,12 KA - 000056 AKl.01 Loss of Offsite Power Knowledge of the operational implications of the following concepts as they apply to Loss of Offsite Power:

Principle of cooling by natural convection RO/SRO Value - (3.7 / 4.2) CFR - 41.8 / 41.10 / 45.3 SOURCE: INPO # 2021 1 Cook 1 - 9/10/2001 Retake #46 From Bank 01 EOPC0309-1 Original Quest. KA - 056.AK1.01 2/20/2006 Page 24 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~~~~~~ 18.

~~~~~~ 018 001/RO/OK/MODIFIEDISEABROOK

~~~~

~

~~ 2003/000058 2.2.26/(2.5.!//3~.

~~~~~~~~~

~

~~~

~~

The following plant conditions exist:

-The plant is mode 6.

- Core offload is currently underway.

- The protected train is A. All equipment needed for a proper protected train alignment is available.

- DC bus AB is deenergized for maintenance.

- DC bus CD deenergizes due to equipment failure.

What action must occur due to the deenergized bus?

A? Immediately suspend core alterations and movement of irradiated fuel.

B. Immediately suspend core alterations. Fuel movement may continue in the Auxiliary Building.

C. Re-energize DC bus AB or CD within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, or declare the Electrical Distribution system inoperable.

D. Re-energize DC bus AB or CD within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, or suspend core alterations and ANSWER: A - Technical Spe'sfication 3.8.5 requires one DC train to be OPERABLE.

Immediate suspension of all core alterations fuel movement is required if both are lost B - Incorrect - Fuel Movement in the Auxiliary Building must also be stopped. Plausible since several specs allow Fuel Movement while requiring Core Alts to be stopped.

C - Incorrect - The electrical system would be declared inoperable immediately and also requires suspension of core alterations & fuel movement.

D - incorrect - Action is required immediately. The 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> action is from Technical Specification 3.8.4 DC Sources-Operating loss of one bus.

movement of irradiated fuel.

~~~~~~~

~~

~-

~~~~

~

~

~~~

~

~~~~~~~

~~~~

~~

~

~

~~~~~

~~

~~~~

2/20/2006 Page 25 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test Changed to loss of all DC and required suspension of core alts/fuel movement

REFERENCE:

ITS 3.8.5 LESSON PLAN/OBJ: RO-C-ADM13/#ADM13.3 KA - 000058 2.2.26 Loss of DC Power Equipment Control Knowledge of refueling administrative requirements.

RO/SRO Value - (2.5 I 3.7) CFR - 43.5 / 45.1 3 SOURCE: INPO # 24707 Seabrook 1 - 5/30/2003 Original Quest. KA - 058.AK1.01 2/20/2006 Page 26 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

19. 019 006/RO/OK/NEW//000061

~.

AK2.0=2/2.6)//F/3

~~~~ ~____

.~~

-~~~

Which of the is the expected response to a High Radiation Signal on the ERS-7407 Unit 1 Control Room Area Radiation Monitor?

A? Only the Unit 1 East and West Pressurization fans start and Dampers align.

B. Either the Unit 1 East -OR-West Pressurization fan starts and Dampers align depending on which Control Room Air Handling Unit is in Service.

C. Only the Unit 1 and Unit 2 East Pressurization fans start and Dampers align.

D. Both the Unit 1 and Unit 2 East and West Pressurization fans start and Dampers align.

A N S W - E ~ - ~ 2 ~ P : 4 0 ~ ~ 1 3 9 ~ p

  1. 12 statesThatbmhe andqest Pressurization fans will start and the associated dampers align.

B - Incorrect - Both the East and West Pressurization fans will start and the associated dampers align. One Pressurization fan must be manually stopped.

C - Incorrect - Both the Unit 1 East and West Pressurization fans will start and the associated dampers align. A SI signal on either Unit starts All Pressurization fans on both units. One Pressurization Fan on each Unit is manually stopped.

D-Incorrect - Both the Unit 1 East and West Pressurization fans will start and the associated dampers align. A SI signal on either Unit starts All Pressurization fans on both units. One Pressurization Fan on each Unit is manually stopped.

REFERENCE:

12-OHP-4024-139 drop #12 LESSON PLAN/OBJ: RO-C-O1350/#4 KA - 000061 AK2.01 Area Radiation Monitoring (ARM) System Alarms Knowledge of the interrelations between the Area Radiation Monitoring (ARM) System Alarms and the following:

Detectors at each ARM system location RO/SRO Value - (2.5 / 2.6) CFR - 41.7 / 45.7 2/20/2006 Page 27 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~~~

20.

~~

020 004/RO/OKiD1RECT/12AOPS05

~~~~~~~~~

15/000062 AK3.03/(4.0 / 4.2)//F/3

~

~~~~

, ~~~

~~

~~

Unit 1 is operating at 100%, steady state condition, when Annunciator Panel 118, Drop 84, ESW PIPE TUNNEL SUMP LEVEL HI-HI, alarm is received. East ESW supply and return flows indicate an abnormal high differential.

Unit 2 has reported that 02-OHP-4022-019-001, ESW SYSTEM LOSS/RUPTURE has been implemented.

What action(s) should be taken FIRST by BOTH Unit control room operators?

A. Align alternate ESW cooling to non affected diesel generators.

i

~

B. Stop affected header ESW pumps.

C. Place associated diesel generators in tripped condition D!' Close affected header unit crosstie valves.

ANSWER: D - When ESW supply and return flows indicate an abnormal high differential both units are directed to isolate the affected header unit crosstie valves.

A - Incorrect - The alternate ESW cooling to the EDGs is isolated per step 15.

B - Incorrect The header crosstie valves are closed first to prevent loss of the opposite unit.

C - Incorrect - The affected EDG is placed in the tripped condition after the headers are isolated and ESW pumps are stopped.

REFERENCE:

RO-C-AOP-5, Abnormal Operating Procedures - Day 5 pg. 52; 01-OHP 4022.019.001, ESW SYSTEM RUPTURE, Step 10 I

~~~~~~

~~

~

~~

~~~

~~~~~~

~

~

~

~~

~

~

~

~~~~~

. ~

~

~~~

LESSON PLANS/OBJ: RO-C-AOP-5/#AOP5.15 KA - 000062 AK3.03 Loss of Nuclear Service Water Knowledge of the reasons for the following responses as they apply to the Loss of Nuclear Service Water:

Guidance actions contained in EOP for Loss of nuclear service water RO/SRO Value - (4.0 / 4.2) CFR - 41.5 / 41.10 / 45.6 / 45.13 Original Question Source: Bank 12AOPS0515-1 WA: 076000 A2.01 (3W3.7)

EXAM/QUIZZES: Q1805D; Ql805E; R1800B5; 180063; Q1908C; Q1908A; RQ2804E; RQ2804B 2/20/2006 Page 28 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~ 21. 021

..- 001iRO/OKiNEW//000068

~

AAI.OSi(4.2 /4.2)i/W3

~~~~

.~

~~~~~

The control room has been evacuated per 02-OHP-4025-001-001, Emergency Remote Shutdown.

The crew has performed 02-OHP-4025-LS-6-1, Seal Injection from CVCS Cross-Tie and 02-OHP-4025-LS-6-3, BIT Injection alignment.

Which one of the following describes the source and method of monitoring borated water addition?

Prior to aligning RHR for shutdown cooling, RCS boration is accomplished by A. manually aligning Unit 1 Boric Acid makeup to feed Unit 2 through the crosstie.

Flow is tracked by Unit 1 Boric Acid flow recorder.

B. locally aligning Unit 2 Boric Acid makeup to feed Unit 2 through the crosstie. Flow is tracked by Boric Acid Flow indicator on the Local Instrument Panel.

C. manually aligning Unit 1 CCP suction to the RWST to feed Unit 2 through the crosstie. Flow is tracked by the sum of local seal injection flows and the Unit 1/2 CCP Crosstie Flow indicator.

D? manually aligning Unit 1 CCP suction to the RWST to feed Unit 2 through the ANSWERID - Prior to initiating the Unit Crosstie, Unit 1 is directed to trip the unit and align CCP suction to the RWST. The Total flow from Unit 1 to Unit 2 is indicated on the Unit 112 CCP Crosstie Flow indicator.

A - Incorrect - Unit 1 is aligned to the RWST. If Unit 1 was aligned to the VCT, this would be a valid flowpath.

B - Incorrect - Unit 2 CCPs are placed in Lock-out prior to evacuating the control room.

Unit 2 Boric Acid flow would be at too low of pressure to inject into the discharge pressure of the Unit 1 CCP through the crosstie. The Pressurizer level is monitored at the local panels.

C - Incorrect - All Unit Crosstie flow travels through the Unit 1/2 CCP Crosstie Flow indicator. Adding the seal injection flow would count that flow twice.

crosstie. Flow is tracked by the Unit 1/2 CCP Crosstie Flow indicator.

~~~~~~

~~~~~

~

2/20/2006 Page 29 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

02-OHP-4025-001-001, Emergency Remote Shutdown, 02-OHP-4025-LS-6-1, Seal Injection from CVCS Cross-Tie, 02-OHP-4025-LS-6-3, BIT Injection, SOD00300-001 LESSON PLAN/OBJ: RO-C-EC002/#4 KA - 000068 AA1.08 Control Room Evacuation Ability to operate and/or monitor the following as they apply to the Control Room Evacuation:

Local boric acid flow RO/SRO Value - (4.2 / 4.2) CFR - 41.7 / 45.5 / 45.6 2/20/2006 Page 30 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~

22. 022 OIO/RO/OK/MODIFIED/COOK 2002 NRC 016-1/000069

-.AK2.03/(2.8 /2.9)//F/2

~~

~

Which ONE of the following conditions would require an LCO Action Statement entry for Technical Specification Section 3.6, Containment Systems?

A. While in MODE 1, an electrician opens the outer airlock door at the lower containment access without prior approval.

B. While in MODE 3, Containment internal pressure is found to be -0.5 psig prior to placing Containment Purge in service.

C!' While in MODE 4, The outer airlock door interlock is discovered to be non-functional.

D. While in MODE 5, during performance of the Overall Integrated Containment Leakage Rate Test, Containment leakage exceeds the maximum allowable Technical Specification leakage rates.

~

.~

~~~~~~~

~~~~~~~~

~

~~~~~~

~~~

~~

~

~~

~~~

~~

~

ANSWER: C - The airlock doorinterlocks are required to be operable in Modes 1 - 4 per T.S. 3.6.2.

A - Incorrect - One airlock door may be opened for normal entry / exit while in Modes 1

- 4 per T.S. 3.6.2.

B - Incorrect - Containment pressure limits are -1.5 to +0.3 psig during Modes 1 - 4 per T.S. 3.6.4.

D - Incorrect - Overall Containment leakrate only applies in Modes 1 - 4 per T.S. 3.6.1 2/20/2006 Page 31 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test Changed correct answer by modifying distractors B & C to reflect airlock interlock vs.

equipment hatch & Internal pressure to Mode 3 vs. 4. Modified wording in stem to ask for LCO entry instead of "Loss of Cont. Operability" & feedback slightly for ITS. -

REFERENCE:

Tech Spec 3.6.1 & Basis 3.6.1 pg. 83.6.1-1 12-1 -05 LESSON PLAN/OBJ: RO-C-TSO1 / #12 KA - 000069 AK2.03 Loss of Containment Integrity Knowledge of the interrelations between the Loss of Containment Integrity and the following:

Personnel access hatch and emergency access hatch RO/SRO Value - (2.8 / 2.9) CFR - 41.7 / 45.7 SOURCE: INPO # 2281 2 Cook 1 - 12/9/2002 #016 (RO#12/SRO#15)

From Dev bank TS-38 Original Quest. KA - 000069.K2.03 Loss of Containment Integrity

- Knowledge of the interrelations between the Loss of Containment Integrity and the following: Personnel access hatch and emergency access hatch 2/20/2006 Page 32 of 146

OC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

23. 023 C~IIROIOWDIRECT-INPOIKEWAUNEE 2004/~i10076 AA~.OZ/(Z.S

.~

I 3.4)//~/2

~~

~

The following conditions exist:

-A runback from 80% to 60% power occurred 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> ago.

-Chemistry samples of the RCS indicate high dose-equivalent 1-1 31.

Why is it desirable to maximize letdown flow under these conditions?

A. To control RCS pH.

BY To reduce RCS activity.

C. To reduce RCS corrosion products.

D. To control RCS boron concentration.

ANSWER: B OHP-4022-002-019 directs the operator to verify Letdown lineup and maximize letdown flow to help reduce RCS Activity.

A - Incorrect - CVCS does provide pH control but it is through Lithium addition and cation demineralizer operations.

C - Incorrect - CVCS will provide cleanup of corrosion products through the filter and to some extent through the demineralizers, but the reason for maximizing letdown flow is to reduce activity.

D - Incorrect - CVCS will provide for adjusting boron concentration. The turnover or exchange is quicker with a higher letdown flowrate (and therefore charging), but the reason for maximizing letdown flow is to reduce activity.

1

~~

_ _ ~

-~

REFERENCE:

12-OHP-4022-002-019, High Reactor Coolant Activity or Failed Fuel LESSON PLAN/OBJ: RO-C-AOP07NIAOP7.9 KA - 000076 AA2.02 High Reactor Coolant Activity Ability to determine and interpret the following as they apply to the High Reactor Coolant Activity:

Corrective actions required for high fission product activity in RCS RO/SRO Value - (2.8 / 3.4) CFR - 43.5 / 45.13 SOURCE: INPO # 26864 Kewaunee, Unit 1 - 2/2/2004 Original Quest. KA - 000076K305 2/20/2006 Page 33 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~~~ 24. 024 O03/RO/OWoIRECT-INPO/POINTBEACH2002/00IOO0~AI.06/(4. I / 4.4)//H/2

~ -

The following conditions exist:

- Unit 2 is operating at 90% Reactor Power.

- Rod Control is in automatic with Bank 'D' Control Rods at 210 steps.

- A Turbine Runback occurs for one minute.

After plant conditions have stabilized, which ONE of the following choices correctly reflects control rod position and axial flux response?

CONTROL ROD POSITION AXIAL FLUX A. Higher in the core Higher in the core B. Higher in the core Lower in the core C. Lower in the core Higher in the core D? Lower in the core Lower in the core ANSWER: D - A turbine runback will result in a reduction of 1st Stage Turbine Pressure. This will cause rod control to see a Power Mismatch (and Temperature Mismatch) and insert rods to reduce reactor power (and Tave). Inserting the Control Rods will drive power lower in the core.

A - Incorrect - Rods will insert causing more power to be produced lower in the core.

B - Incorrect - Rods will insert.

C - Incorrect - More power will be produced lower in the core.

~

~~

~~

~~~~~~

~~~~~~~

~~~

~~~~

~~

~~

~~~

REFERENCE:

RO-C-GF26, Reactor Transients; RO-C-01200, Rod Control and Rod Position Indicating System LESSON PLAN/OBJ: RO-C-GF26\\#lI RO-C-O1200/#7, RO-C-AOPOl/#TOl KA - 001 000 Al.06 Control Rod Drive System Ability to predict and/or monitor changes in parameters (to prevent exceeding design limits) associated with operating the CRDS controls including:

Reactor power RO/SRO Value - (4.1 / 4.4) CFR - 41.5 / 45.5 SOURCE: INPO # 20600 Point Beach 1 - 2/2/2002 Original Quest. KA - 001.A3.03 2/20/2006 Page 34 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

25. 025 00 I/RO/OWDIRECT-INPO/INDIANPOINT3-2003/002000 K6.07/(2.5 / 2.8)//H/3

~

~~

~~~~~~

~

.~~

~ _ _ ~

~~~

..~

While at 20% power with a power ascension in progress, RCP 11 trips due to an overcurrent condition.

No operator action has been taken and no rod motion has occurred.

Which ONE (1) of the following describes the INITIAL reactor and Loop 11 response?

A? A reactor trip WILL NOT occur and Loop 11 Tavg will LOWER.

B. A reactor trip WILL NOT occur and Loop 11 Tavg will RISE.

C. A reactor trip WILL occur and Loop 11 Tavg will LOWER.

D. A reactor trip WILL occur and Loop 11 Tavg will RISE.

ANSWER: A - A single RCP trip will not cause an automatic reactor trip below P-8.

Once the RCP trips, The entire associated loop temperature will go to the Tcold or SG Saturation Temperature causing the Tavg to lower B. Incorrect. Tavg will lower C. Incorrect. No trip below 29% power D. Incorrect. No trip below 29% power and Tavg will lower i

~~

~~.~~~~

~~~

___..~__~

~ _ _ _ _ ~

~~

~~~

~~

. --~~,

REFERENCE:

RO-C-TRANS4, RCS Loop Flow Transients pg. 25-30; RO-C-AOP04, Abnormal Operating Procedures - Day 4 LESSON PLAN/OBJ: RO-C-TRANS4/#TRANS4A.3; RO-C-AOP04/#AOP4B KA - 002000 K6.07 Reactor Coolant System (RCS)

Knowledge of the effect of a loss or malfunction on the following RCS components:

Pumps ROISRO Value - (2.5 12.8) CFR - 41.7 145.7 SOURCE: INPO # 23437 Indian Point 3 (Unit) - 311012003 Original Quest. KA - 002.k6.02 212012006 Page 35 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

26.

and 1 During a recent degassing operation of the RCS, Volume Control Tank (VCT) level was raised to 70% without any concurrent adjustment in VCT pressure as level rose.

This caused Reactor Coolant Pump (RCP) #1 seal leakoff flow to (1)

I will require (2) to restore seal leakoff flows to normal.

026 001/RO/OK/DIRECT-INPO/BRAIDWOOD

~~

~

~.

~~

2002/003000 AZ.OY(2.5

~~~~~

/ 2.8)//H/3

~

~~~~

i

~~

(1)

-~

(2) 1 A. rise opening up 1-QRV-200, Charging Header Pressure Control BV lower venting the VCT C. lower closing down 1 -QRV-200, Charging Header Pressure Control D. rise venting the VCT ANSWER: B - Raising VCT level without venting the VCT will cause Pressure to rise.

This will place more backpressure on the RCS seals and cause seal leakoff flow to lower.

~~

~~

~

~

~~~~

~

~~

~~~~

~

A - Incorrect - Seal leakoff flow will lower & the VCT must be vented. Plausible if the candidate thinks that the VCT pressure rise would cause higher charging pressure rising seal injection flow.

C - Incorrect - Seal leakoff flow will lower, but the VCT must be vented. Plausible if the candidate thinks that raising charging pressure to provide more seal injection flow will correct the low leakoff flow.

D - Incorrect - Seal leakoff flow will lower &the VCT must be vented. Plausible if the candidate thinks that the VCT pressure rise would cause higher charging pressure rising seal injection flow.

2/20/2006 Page 36 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

RO-C-201, Reactor Coolant Pumps, RO-C-AOP04, Abnormal Operating Procedures - Day 4 LESSON PLAN/OBJ: RO-C-AOP04/#AOP4.21 KA - 003000 A2.05 Reactor Coolant Pump System (RCPS)

Ability to (a) predict the impacts of the following malfunctions or operations on the RCPS and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations:

Effects of VCT pressure on RCP seal leakoff flows RO/SRO Value - (2.5 / 2.8) CFR - 41.5 143.5 / 45.3 / 45.13 SOURCE: INPO # 21410 Braidwood 1 - 7/17/2002 Original Quest. KA - 003.a2.05 2/20/2006 Page 37 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~~~

27..~

027 002/RO/OWDIRECT/O1COMC0207-39/003000

~~.~

~~~

.. ~~

A4.02/(2.9

~~

/2.9)/R1/2

.~

~~~

~

~~~~~~~

~

~

A reactor coolant pump (RCP) is circulating reactor coolant at 1 OOOF. After several hours the reactor coolant temperature has risen to 1 5OoF.

Assuming coolant flow rate (gpm) is constant, RCP motor amps will have (1) because (2)

A.

risen system head losses have lowered B. lowered system head losses have risen I

1 C.

risen coolant density has risen DJ lowered coolant density has lowered ANSWER: D - As RCS temperature raises the coolant density lowers. The pumps will perform less work to move the lighter coolant resulting in a reduction of current required.

A - Incorrect - Density lowers requiring less amps. System configuration does not change so head losses are consistent.

B - Incorrect - System configuration does not change so head losses are consistent C - Incorrect - Density lowers requiring less amps.

REFERENCE:

RO-C-GF17, Pumps (GP Components 2) pg. 40, RO-C-00201, Reactor Coolant Pump System pg. 27

~~~

~

~~

~

~~~~~

~~~

~~~~

~

~~~

LESSON PLAN/OBJ: RO-C-GF17/7b KA - 003000 A4.02 Reactor Coolant Pump System (RCPS)

Ability to manually operate and/or monitor in the control room:

RCP motor parameters RO/SRO Value - (2.9 / 2.9) CFR - 41.7 / 45.5 to 45.8 Original Question Source: Bank 01 COMC0207-39 From GFES# 335;BANK: P2023 (B2020)

Original KA - 191004 K1.07 (2.9l2.9)

Exam/Quizzes: R024GFES04 2/20/2006 Page 38 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~~~~~~~~~~~~~

~~~~~~~~~

~

~~~~~ 28. 028 003/RO/OK/NEW//004000

~

K3.07/(3.8

~~~~~

/4.

~~~

I)//H/3

~~

Unit 2 Power is 75%.

Which ONE of the followina describes the effect on the dant if QRV-251 Charaina Flow Control Valve fails closed (assume no operator aciion)?

Pressurizer level lowers until letdown isolates and PRZ heaters deenergize; pressurize1 level...

A!, continues to lower and pressure lowers until the Reactor trips on Low Pressurizer Pressure.

B. continues to lower and pressure lowers until the Reactor trips on (OTDT) Over Temperature Delta Temperature.

C. then rises and pressure rises until the Reactor trips on High Pressurizer Pressure.

D. then rises until the Reactor trips on High Pressurizer Level.

ANSWER:~A --When?he~QRV-251 fails closed all Charging line and Seal Injection flow is stopped. Pressurizer level will lower until letdown isolates at 17%. Pressure Heaters will also trip off. Pressurizer level will continue to lower and pressure will lower (from no heaters and level loss) until the Reactor trips on Low pressure at 1875 psig.

B - Incorrect - Pressure does input to OTDT but the impact is small without a corresponding temperature change. The reactor will trip on Low pressure first.

C - Incorrect - Seal Injection is isolated so level will not rise and heaters remain de-energized. Plausible if this were a level channel failure & Reactor did not trip on High level.

D - Incorrect - Seal Injection is isolated so level will not rise and heaters remain de-energized. Plausible if this were a level channel failure as the Reactor would trip on High level.

REFERENCE:

SOD-00202-003 Pressurizer Level Control System and SOD-00300-001 Charging and Letdown System.

~

~

.. ~ ~

~

~

~

~

~

~~~~~~

~

~

~~

~

~

~~~~

~~~~~

~~~~

LESSON PLAN/OBJ: RO-C-0300/#8, RO-C-0202/#11 KA - 004000 K3.07 Chemical and Volume Control System (CVCS)

Knowledge of the effect that a loss or malfunction of the CVCS will have on the following:

PZR level and pressure RO/SRO Value - (3.8 / 4.1) CFR - 41.7 / 45.6 2/20/2006 Page 39 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~~~~~~ 29. 029 001/RO/OK/NEW//005000

.. ~.

A2.01/(2.7 /2.9)//H/3

~-

.~~

.~

~~~~~

~~~~~~~~

~~

~

~

~

~

~

~~~~~~~~

~~~~~

The following conditions exi3:

- Unit is in Mode 4 during cooldown per OHP-4021-001-004, Plant Cooldown from Hot Standby to Cold Shutdown

-West RHR Pump is operating with the return aligned to the Alternate Cooldown Path

- RCS temperature is 300°F and stable

- RCS pressure is 335 psig and stable The air supply line to IRV-320, West RHR Hx Outlet Valve, breaks, causing a complete loss of Instrument Air to the valve.

Which ONE (1) of the following describes the effect on the plant and the action required to mitigate the transient?

to Loops 2 & 3.

A. RHR Flow through the West HX will be lost, IRV-311 RHR HX Bypass will have to be throttled open to maintain greater than 3000 gpm RHR flow.

B. RHR Flow through the West HX will be lost. The West RHR pump should be stopped immediately to prevent overpressurizing letdown.

C. RHR Flow through the West HX will rise. ICM-111, RHR Discharge to Cold Leg 2 &

3 and IRV-311 RHR HX Bypass should be throttled to prevent overcooling the RCS.

D!' RHR Flow through the West HX will rise. The ICM -321, West RHR Injection to Loops 2 & 3 and IRV-311 RHR HX Bypass should be throttled to prevent overcooling the RCS.

~

~~

~~~~~~

~~

~~~~

~

~~~~~~~~~~~~~~~

~

~

~

~~~

~~~~

~~~~

~

~

ANSW~ER: D - IRV-320 fails open on loss of air. This will raise RHR flow through the HX. The ICM-321 can be throttled closed to reduce total RHR flow and IRV-311 can be throttled open to allow more flow to bypass the HX in order to control RCS cooldown.

A - Incorrect - IRV-320 fails open so flow will raise. Plausible since RHR flow is maintained > 3000 gpm to minimize vibrations & cavitation through the piping.

B - Incorrect - IRV-320 fails open so flow will raise. Plausible since RHR flow to the letdown system taps off before the IRV-320 and if IRV-320 closed it may raise letdown pressure.

C - Incorrect - The ICM-111, RHR Discharge to Cold Leg 2 & 3 is in the NORMAL Cooldown Path and should only be used if the Alternate cooldown path is unavailable.

This would be correct if the Normal Cooldown path was used. (02-OHP-4021-017-002 3.10) 2/20/2006 Page 40 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

02-OHP-4021-017-002, Placing in Service the RHR System; 02-OHP-4022-064-002, Loss of Control Air Recovery (Step 43 & Att. B-9)

LESSON PLANIOBJ: RO-C-O1700/#6 KA - 005000 A2.01 Residual Heat Removal System (RHRS)

Ability to (a) predict the impacts of the following malfunctions or operations on the RHRS and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations:

Failure modes for pressure, flow, pump motor amps, motor temperature, and tank level instrumentation ROISRO Value - (2.7 I 2.9) CFR - 41.5 I 43.5 I 45.3 I 45.1 3 212012006 Page 41 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

[--~

30. 030 001/RO/OWNEW//006000 K1.10/(2.6

~~

/ 2.8)//F/2

~

~~~

~

~~~~~~

Which one of the following describes the freeze protection for the Unit 1 and Unit 2 Refueling Water Storage Tanks (RWST)?

A. Both Units use banks of heat tracing on the outside of the tank.

8. Both Units use a recirculation loop comprised of a pump and electric water heaters.

C. Unit 1 uses a recirculation loop comprised of a pump and electric water heaters, D?' Unit 1 uses banks of heat tracing on the outside of the tank, while Unit 2 uses a ANSWER: D - Unit 1 uses banks of heat tracing on the outside of the tank, while Unit 2 uses a recirculation loop comprised of a pump and electric water heaters.

A - Incorrect - Unit 2 uses a recirculation loop comprised of a pump and electric water heaters.

B - Incorrect - Unit 1 uses banks of heat tracing on the outside of the tank C - Incorrect - This is the opposite of the actual configuration.

while Unit 2 uses banks of heat tracing on the outside of the tank.

recirculation loop comprised of a pump and electric water heaters.

~

~~~~~

~~~~~~

~~~~~~

~~.

~

REFERENCE:

RO-C-00800, Emergency Core Cooling System pg. 35-36 LESSON PLAN/OBJ: RO-C-00800/#3,4 KA - 006000 K1.10 Emergency Core Cooling System (ECCS)

Knowledge of the physical connections and/or cause-effect relationships between the ECCS and the following systems:

Safety injection tank heating system RO/SRO Value - (2.6 / 2.8) CFR - 41.2 to 41.9 / 45.7 to 45.8 SOURCE: INPO # 0 -

Original Quest. KA - 006000 kl.10 2/20/2006 Page 42 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test A. If the level is too low the radioactive gases that leak from the top of the Pressurizer would not be adequately scrubbed, thus causing subsequent elevated gaseous activity levels inside Containment.

B. If the level is too high, the tank will overflow to Containment sump causing possible false indications of RCS leakage to Containment.

Cr' If the level is too low, there would be insufficient water volume to absorb and condense a design discharge of Pressurizer safety leading to possible over temperature and overpressure of the PRT.

D. If the level is too high, the sparger pipe will be too far underwater rendering the cooling affect of makeup water ineffective.

~~-~

.~

~~~~~

~~~

~~

~

~~

~

~

~~

~~~~~

~

~~

~~

~

~

~

~

~

31. 03 I OOl/RO/OK/LlIRECT-INPO/GINNA 2004-27292/007000 2.1.1/(3.7 /3.8)//H13 Which of the following describes the adverse affects of NOT maintaining the Pressurizer Relief Tank (PRT) within design level band?

2/20/2006 Page 43 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

UFSAR Chapter 4 pg. 17-18 and Table 4.1 -4 LESSON PLAN/OBJ: RO-C-00202\\#7 KA - 007000 2.1.1 Pressurizer Relief TanWQuench Tank System (PRTS)

Conduct of Operations Knowledge of conduct of operations requirements.

RO/SRO Value - (3.7 / 3.8) CFR - 41.1 0 / 45.1 3 SOURCE: INPO # 27292 Ginna 1 - 4/27/2004 Original Quest. KA - 007A1.01 2/20/2006 Page 44 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

32.

032 001/RO/OWDIRECT/COOK 2001 Q#51/007000 K5.02/(3,1 / 3.4)/@/3

~

~~~~~~~~~~~~

~~.

The following conditions exist:

- Unit 2 was in cold shutdown with the RCS drained to mid-loop.

- Filling and venting is in progress.

- Pressurizer level is 100%.

- A nitrogen blanket is on the PRT; PRT level is at 5%.

- The gaseous waste disposal system is aligned to support a bubble.

- The PZR heaters are energized.

Prior to drawing a bubble in the pressurizer which one of the following must be accomplished?

A. Pressurize the RCS to 325-350 psig

6. Establishing 50% in the pressurizer C. Bumping the RCPs to remove entrapped gases D!' Filling the PRT to 80-85%

ANSWER: D - After the Pressurizer has been filled to >loo% (level change seen in PRT), the PRT is re-aligned and the Level is raised to the normal operating band of

~~~~~~~~

~~

~~~~~~~

~

~~

~~~~

~

~~

~~~

~

~

~~~~~

80-85%.

A - Incorrect - The RCS pressure is maintained around 50-60% while a bubble is drawn. Plausible since pressure is raised to 325-350 psig after the bubble is drawn.

B - Incorrect - The pressurizer is maintained at 100% until the bubble is drawn.

Plausible since level is reduced to 50% after the bubble is drawn.

C - Incorrect - The RCS is pressurized prior to bumping the RCPs. Plausible since the RCS is vented prior to drawing the bubble and the RCPs are bumped after the bubble is drawn.

Deleted "RCS is aligned to vent..." from stem 4th line.

REFERENCE:

02-OHP-4021-002-001 Filling and Venting the RCS (Steps 4.60-4.63)

LESSON PLAN/OBJ: RO-C-NOP04/#25 KA - 007000 K5.02 Pressurizer Relief TanWQuench Tank System (PRTS)

Knowledge of the operational implications of the following concepts as they apply to the PRTS:

Method of forming a steam bubble in the PZR RO/SRO Value - (3.1 / 3.4) CFR - 41.5 / 45.7 SOURCE: INPO # 19506 Cook 1 - 5/21/2001 Original Quest. KA - 007.k5.02 2/20/2006 Page 45 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

33.

~~

033 OOl/RO/OK/NEW//0OSOOO A1.04/(3.1 /~3.2)/@/4

~..

The followina conditions exist:

- U2 is at 1 O'i% Power with normal operating temperature and pressure

- The East CCW pump is running

- The water level in the CCW surge tank is 58" and slowly lowering

-The makeup valves to the CCW surge tank are fully open Which one of the following actions is required by 02-OHP-4022-016-001, Malfunction of the CCW System?

AJ Start the West CCW pump, split the East and West Headers, when surge tank leve is < 48" identify and isolate the leaking header.

B. Start the West CCW pump, split the East and West Headers, and shutdown the East CCW pump.

commence an rapid plant shutdown.

C. Isolate letdown, excess letdown, place standby CCW switch in Lock-Out and D. If level cannot be maintained > 48", trip the Rx, trip RCPs and go to E-0.

ANSWERYA- -The CCW Surge taikhasabafTkihaGxtends to 48. The procedure has the operator split the CCW headers and then monitor the CCW surge tank level indicators after surge tank level has lowered to <48" (height of baffle). Two surge tank level indicators monitor both sides of the baffle. When it is identified which side is leaking that header is isolated.

B - Incorrect - The surge tank levels are monitored after level lowers to <48" to determine which train is leaking. The east pump is not stopped until it is determined which header is leaking. Additionally, the Miscellaneous header is initially aligned to the East CCW header. Plausible since the East Pump was initially running.

C - Incorrect - A plant Shutdown is not required with a slow level reduction. Letdown would be an inleakage source. Plausible since placing the standby pump in Lock-Out would be conservative to protect the pump.

D - Incorrect - The surge tank baffle only extends to 48" so level must be allowed to lower to <48" to identify the leaky header. Plausible since these actions are required if CCW pumps must be stopped due to cavitation.

~

~~~~

~~

~~~~~~

~~~~~~~

~

2/20/2006 Page 46 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

02-OHP-4022-016-001, Malfunction of the CCW System Steps 3, 5-1 1 LESSON PLAN/OBJ: RO-C-AOP11/#11.19 KA - 008000 Al.04 Component Cooling Water System (CCWS)

Ability to predict and/or monitor changes in parameters (to prevent exceeding design limits) associated with operating the CCWS controls including:

Surge tank level RO/SRO Value - (3.1 / 3.2) CFR - 41.5 / 45.5 2/20/2006 Page 47 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

34. 034 002/RO/O~lRECT-INPO/SURRY2~3-25785/OOWE0I EA2.2K3.3 /3.9)//F/2

~~~

~~~~

~

~

~

~~~~~~

Which one of the following correctly describes the conditions~'that allow implementation of 02-OHP-4023-ES-0.0, Re-Diagnosis?

A. Entry is based solely on operator judgement and 02-OHP-4023-ES-0.0 may be entered at any time.

Trip/Safety Injection completion provided that SI is actuated.

E!' Entry is based on operator judgement anytime after 02-OHP-4023-E-0, Reactor C. 02-OHP-4023-ES-0.0 may be entered anytime after the EOP's have been entered.

D. 02-OHP-4023-ES-0.0, may be entered anytime that SI is actuated and a Function Restoration (FR) procedure is in effect.

~~~

~~

~

ANSWER: B - An SI must be in service, anbE-0 has been completed A. Incorrect, ES-0.0 entry requires an SI to be in service and E-0 to be completed.

C. Incorrect, E-0 must be completed.

D. Incorrect, an SI must be present, and E-0 completed. Section 4

REFERENCE:

OHl-4023, ABNORMAUEMERGENCY PROCEDURE USER'S GUIDE, LESSON PLAN/OBJ: RO-C-EOP01/#24 KA - OOWEOl EA2.2 Rediagnosis Ability to determine and interpret the following as they apply to the Reactor Trip or Safety Injection/Rediagnosis:

Adherence to appropriate procedures and operation within the limitations in the facility's license and amendments RO/SRO Value - (3.3 / 3.9) CFR - 43.5 / 45.13 SOURCE: INPO # 25785 Surry 1 - 3/14/2003 Original Quest. KA - WEOlGW.45.1 2/20/2006 Page 48 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~~~~ 35. 035

~ 004/RO/OKIDIRECT/AUDIT R023 Q#16/00WE04 EA2.1/(3.4 / 4.3)//H/3

~~

~

~~~~~~~~~

~

Unit 1 is responding to a LOCA using 01-OHP-4023-E-1 (Loss of Reactor or Secondary Coolant) that occurred 25 minutes ago.

The following conditions exist::

- RWST Level = 45%

- Containment pressure = 1.5 psig

- Containment Radiation = 600 mR/Hour

- Containment Recirc Sump Minimum Recirc Level Lights - NOT Lit

- East RHR Pump Compartment Sump Annunciator - Lit

- Aux Building area radiation monitors are in alarm Which ONE of the following actions are required?

A? Transition to 01 -0HP-4023-ECA-1.2 (LOCA Outside Containment) to address the RHR leakage.

B. Transition to 01 -0HP-4023-FR-Z.3 (Response to High Containment Radiation Level) to address high Containment Radiation.

C. Transition to 01 -0HP-4023-ECA-1.1 (Loss of Emergency Coolant Recirculation) to address the loss of recirculation capability.

D. Remain in 01-OHP-4023-E-1 (Loss of Reactor or Secondary Coolant) but shutdown the Containment Spray Pumps.

~

~

~~~~~~

~

~

~

~

~~~~~

~~~

~

~

~~

~~~

~~

~

~

~~~~~~~

~

~~

~

~

~~~~

~

~~

ANSWER: A - Plant sump alarmsand radiation monitors are both checked to identify leakage in the auxiliary building. this check is made to determine if the operator should make a transition to 01-OHP-4023-ECA-1.2, LOCA Outside Containment.

B - Incorrect - The Leakage into the Aux Building is the priority. 01 -0HP-4023-FR-Z.3 entry conditions are NOT met for the Yellow path FR.

C - Incorrect OHP-4023-ECA-1.1 is not entered until sump recirculation capability can NOT be verified or the leak outside containment can NOT be stopped. RWST level is not yet at the low level transition point although the Containment Recirc Sump Minimum Recirc Level Lights NOT Lit.

D - Incorrect - The Containment Spray Pumps are stopped at <2 psig but not until after 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> of run time.

2/20/2006 Page 49 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test Changed RWST level to 45% & Cnmt Rad to 600mR/hr, Removed Cnmt. Hydrogen, &

AEO report in stem. Changed Distractor D from non-existent procedure & added actions to other distracters (from just listed procedures).

REFERENCE:

01-OHP-4023-E-1 Step 11 LESSON PLAN/OBJ:

KA - OOWE04 EA2.1 LOCA Outside Containment Ability to determine and interpret the following as they apply to the LOCA Outside Containment:

Facility conditions and selection of appropriate procedures during abnormal and emergency operations RO/SRO Value - (3.4 / 4.3) CFR - 43.5 / 45.13 Original Source Question AUDIT R023 Q#16 From McQuire M-BANK-359.3-16 Original KA WE 04 EK3.2 (3.4 /4.0) 2/20/2006 Page 50 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~~ 36. 036 005/RO/OKDIRECT/OIEOPC11

~~~~

~ ~.....

~~

I0-6/00WE05 EK2.2/(3.9 / 4.2)/@/3-_ ~.

~.~

~

~

~~~

~.

~~

~~~

Response to Loss of Secondary Heat Sink, 01-OHP-4023-FR-H.l, attempts to restore the secondary heat sink capability before initiating a bleed and feed cooling.

In accordance with 01 -0HP-4023-FR-H.1, the chronological order of preference from Highest to Lowest for restoring SG feedwater is :

1) Auxiliary Feedwater flow (from affected unit)
2) Condensate flow
3) Cross-tied Auxiliary Feedwater flow (from unaffected unit)
4) Main Feedwater flow A. 1,4, 2, 3 B. 4, 1, 3, 2 C* 1, 3, 4, 2 D. 3, 1, 4, 2 ANSWER: C OHP-4023-FR-H.l Step 4 has the operator attempt to restore AFW first. The RNO directs the operator to then use the Opposite Unit AFW. Steps 6-10 aligns Main FW and Steps 1 1-1 5 depressurizes the SGs and aligns the condensate System.

A - Incorrect - Crosstied AFW is used before Condensate and Main FW flow.

B - Incorrect - Both Units AFW systems are tried before Main FW.

D - Incorrect - The associated Units AFW is tried before the crosstie.

~

~~~~~~~~~~~~~~~~~~~

~~

~~

~

~~~~~~~

~~~~~~~~~~~~~~~~

~~

~~~~~~~~~~~~~~~~

~

~

2/20/2006 Page 51 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test Changed order of Distracters A & D

REFERENCE:

RO-C-EOP11 pg. 45,01-OHP-4023-FR-H.1,Response to Loss of Secondary Heat Sink Steps 4-15 LESSON PLAN/OBJ: RO-C-EOPll/#lO KA - 00WE05 EK2.2 Loss of Secondary Heat Sink Knowledge of the interrelations between the Loss of Secondary Heat Sink and the following:

Facility's heat removal systems, including primary coolant, emergency coolant, the decay heat removal systems, and relations between the proper operation of these systems to the operation of the facility RO/SRO Value - (3.9 / 4.2) CFR - 41.7 I45.7 Original Source Question Bank 01 EOPCl 1 1 0-6 Original KA 2.4.23 (2.8/3.8)

Exam/Quizzes: R020ECOMP; R022EOP7A; R022EOP7C; RQ2802V; RQ2802C Similar to INPO # 26856 Kewaunee, Unit 1 - 2/2/2004 and INPO # 27275 Ginna 1 -

412712004 2/20/2006 Page 52 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

37. 037 003/RO/OWDIRECT/01EOPC07I2-2/00WE12

~

EA1.3/(3.4 / 3.9)//F/2

~.,. ~

~

In OHP-4023-ECA-2-1, Uncontrolled Depressurization Of All Steam Generators, a foldout page item listing the.OHP-4023-E-2, Faulted Steam Generator Isolation transition criteria is found.

This should be continuously monitored while performing the actions in OHP-4023-ECA-2.1 because...

A. if a faulted SG completely depressurizes, the operator is directed back to B. if any intact SG level rises in an uncontrolled manner, the operator is directed back C. complete depressurization of all SGs could occur at any time and a prompt OHP-4023-E-2 for prompt identification and isolation.

to OHP-4023-E-2 for prompt isolation of all feed sources to that SG.

transition is required to maintain an adequate Heat Sink.

D!' restoration of the pressure boundary in any SG could occur at any time so the operator is directed back to OHP-4023-E-2 for further optimal recovery actions.

ANSWER: D - The Foldout page has transition criteria based on any SG pressure rising. When this condition exists, the operator is transitioned back to OHP-4023-E-2, since 1 SG is now isolated.

A - Incorrect - While OHP-4023-E-2, is titled 'Faulted Steam Generator Isolation' attempts at isolation have failed so OHP-4023-ECA is used to stabilize the plant.

B - Incorrect - If any intact SG level rises in an uncontrolled manner, the operator is directed to OHP-4023-E-3, SGTR.

C - Incorrect - Complete depressurization is expected during OHP-4023-ECA-2.1. AFW flow is maintained to keep the tubes wetted and may be raised to stabilize temperatures after the SGs are depressurized.

~~

~~

~~~~~~~~~~

~~

~~~~~~~~

~

~

. ~

~~~~

~~

2/20/2006 Page 53 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

02-OHP 4023 ECA-2.1 LESSON PLAN/OBJ: RO-C-EOP07/#12 KA - 00WE12 EA1.3 Uncontrolled Depressurization of all Steam Generators Ability to operate and/or monitor the following as they apply to the Uncontrolled Depressurization of all Steam Generators:

Desired operating results during abnormal and emergency situations RO/SRO Value - (3.4 / 3.9) CFR - 41.7 / 45.5 / 45.6 Original Question Source: Bank 01 EOPC0712-2 Original KA E12EK3.3 3.5/3.7 EXAM/QUIZZES: R020EOP4; R021 EOP3; R022EOP3B; RQ2706VA; RQ2804A; R023EOP3 2/20/2006 Page 54 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

38.

1138 01 l, K ( ~, ( ~ K / l ) l ~ E ~ l, A ~ ! D l T pO?3 Qn8/OIOUUlJ A1.02/13 h / 3 1~//H/3 Unit 1 was operating at 100%when a-pipe bieak occurred on the SG 14 steam header The following conditions exist :

- Main Steam Line Isolation has occurred.

- PRZ level dropped to 0% and has restored to 20%.

- RCS pressure is 1900 psig.

- Safety Injection (SI) has NOT been reset.

Which ONE of the following are the REQUIRED actions to re-energize the Pressurizer back-up heaters?

A. Reset SI Place the back-up heater control switches in the TRIP position.

Place the back-up heater control switches in the CLOSE position

9. Reset SI Place the back-up heater control switches in the PULL-TO-RESET position Place the back-up heater control switches in the CLOSE position.

C. Reset the Pressurizer Master Pressure Controller Place the back-up heater control switches in the NEUTRAL position.

Place the back-up heater control switches in the CLOSE position.

D?' Place the back-up heater control switches in the TRIP position.

ANSWER: D - The Backup heaters will trip off on the low pressurizer level. After level has been restored the control switches must be placed in the trip condition to reset the breaker. Then the switches are placed to close to energize the heaters.

A - Incorrect - SI reset is NOT Required.

B - Incorrect - SI reset is NOT Required. Switch must be taken to TRIP position to reclose.

C - Incorrect - The Heaters must be placed to Trip to reset the seal-in. Plausible since many controllers have to be reset after the parameter has exceeded limits.

Place the back-up heater control switches in the CLOSE position.

~

~~~~~

~~~~~~

~~

~

~~~~~~~~

~~~~~~~

2/20/2006 Page 55 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

RO-C-00202, Pressurizer and Pressure Relief System pg. 16-24 LESSON PLAN/OBJ: RO-C-00202/#16 KA - 01 0000 A4.02 Pressurizer Pressure Control System (PZR PCS)

Ability to manually operate and/or monitor in the control room:

PZR heaters RO/SRO Value - (3.6 13.4) CFR - 41.7 / 45.5 to 45.8 SOURCE: AUD02-BOTH47, R023 Audit RO#008 /SRO#008 Original Quest. KA - SYS 01 0 G2.1.31 (4.2/3.9) 2/20/2006 Page 56 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

39. 039

~~~~~

OOl/RO/OWDIRECT-INPOPRAIRIE

~~~~~

ISLAND 2004/010000 K1.07/(2.9 /

~~~~~~~~ 3. I)/@/?.

~~

~~~

~~

The following conditions exist:

-Unit 1 is at 100% power

-Pressurizer PORV NRV-151 opens and sticks open.

-The associated PORV block valve cannot be closed

-PRT pressure rises to the point that the PRT Rupture Disc ruptures What is the effect of the disc rupturing?

A. Makeup to the PRT initiates.

B? Containment radiation levels rise.

C. Containment N2 header pressure lowers.

D. PRT level drains below the sparging nozzles.

ANSWER: 8 - When the PRT rupture disc ruptures, The Pressurizerthrough-the PORV & PRT will discharge to containment. This will raise containment radiation, temperature and pressure.

A - Incorrect - While level may lower (water flash to steam) makeup to the PRT is not automatic.

C - Incorrect - While a N2 cover is supplied to the PRT, The regulator will limit the flow out of the N2 to the PRT.

D - Incorrect - Incorrect - While level may lower (water flash to steam), it will not lower below the sparger @ 5%.

~~~~~~

~~~~~~~

Changed correct answer to containment rad vs. PORV outlet temp lowering.

REFERENCE:

RO-C-00202, Pressurizer and Pressure Relief System LESSON PLAN/OBJ: RO-C-00202/#8 KA - 010000 K1.07 Pressurizer Pressure Control System (PZR PCS)

Knowledge of the physical connections and/or cause-effect relationships between the PZR PCS and the following systems:

Containment RO/SRO Value - (2.9 / 3.1) CFR - 41.2 to 41.9 / 45.7 to 45.8 SOURCE: INPO # 27569 Prairie Island 1 - 4/23/2004 Original Quest. KA - 010 K6.04 2/20/2006 Page 57 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

40. 040 OOl/RO/OWDIRECT-INPOIBYRON

~-

2003 - 26398/011000 K3.02/(3.5 /3.7)//H/3

~

~

~

The following conditions exist:

- Charging, letdown, and PRZ level control system are in automatic. QRV-160 and 2-QRV-161, Letdown Orifice Valves are Open

- Letdown Hx Outlet Flow QFI -301 118 gpm

- Charging Header Flow QFI -200 127 gpm

- Total seal flow to RCPs QFI -210 to 240 30 gpm The controlling PRZ level channel fails high to an indicated 100% level.

Which of the following describes the short term effect on total RCP seal injection flow, assuming NO operator action?

Total seal injection flow...

A. raises to about 50 gpm B. remains about 30 gpm C?' lowers to about 12 gpm D. lowers to 0 gpm ANSWER: C - With the Pressurizer level channel failed high the charging flow control^

valve QRV-251 will close to the minimum flow position of - 52 gpm. This will cause seal injection flow to lower accordingly.

A - Incorrect - The charging flowpath is not isolated (QRV-200 is still open). This is the minimum charging flow value.

B - Incorrect - The charging flowpath is not isolated (QRV-200 is still open) so flow to the seals will lower as total charging flow lowers.

D - Incorrect - The minimum flow setting on QRV-251 controller will keep some flow going to the seals.

~~~~

~

~~~~~~~

~

~~~~

~

~~~

~~~~~

~..

~

~~~

~~~

~.

2/20/2006 Page 58 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

SOD-00202-003 Pressurizer Level Control System and SOD-00300-001 Charging and Letdown System.

LESSON PLAN/OBJ: RO-C-0202/#5 KA - 01 1000 K3.02 Pressurizer Level Control System (PZR LCS)

Knowledge of the effect that a loss or malfunction of the PZR LCS will have on the following:

RCS RO/SRO Value - (3.5 / 3.7) CFR - 41.7 / 45.6 SOURCE: INPO # 26398 Byron 1 - 12/10/2003 Original Quest. KA - 01 1000.K3.02 2/20/2006 Page 59 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~

41. 041 005/RO/OKfl)IRECT/AUDIT R022-BOTH-23/012000 g.0~1/(3.3

/3.7)/2OH/FL-~,

~~~~~~

~~~~~~~

~

The following plant conditions exist:

- A Un,it 1 startup is in progress.

- The reactor is critical in the source range.

- N41 Power Range channel is removed from service for zero power physics testing.

- A loss of power to the CRlD 2 bus occurs.

Which ONE of the following actions will occur?

A. Reactor trips and N32 Source Range channel is de-energized.

N31 Source Range channel is still in operation.

1 B. The reactor is critical and BOTH source range channels are de-energized.

~

i C. The reactor is critical and N32 Source Range channel is de-energized.

N31 Source Range channel is still in operation.

D? Reactor trips and BOTH source range channels are de-energized.

ANSWER: D ~ - - A loss of CRlD 2 causes a loss of power to N42. This loss also causes a loss of power to RPS channel 2. This will cause a trip condition for Power range trips for channel 2. Since N41 is already removed from service its bistable are in the tripped condition. This meets the 2/4 logic to cause a reactor trip. Additionally the signal for 2/4 power range channels above P-10 will cause the SR channels to deenergize.

A - Incorrect - P-10 will be met, both SR's will de energize.

B - Incorrect - Reactor trips on a number of PR/SR trip setpoints.

C - Incorrect - Reactor trips on a number of PR/SR trip setpoints. Also, P-10 will turn off both SR's.

REFERENCE:

RO-C-01101, Solid State Protection System

~~

~~~~

~~~~

~~

~

~~~~

~~~~~

~

~~~~~

~~

~~~~

LESSON PLAN/OBJ: RO-C-O1101/#6 KA - 01 2000 K2.01 Reactor Protection System Knowledge of bus power supplies to the following:

RPS channels, components, and interconnections ROKRO Value - (3.3 I3.7) CFR - 41.7 Original Source Question AUDIT R022-BOTH-23 Q#20 Original KA SYS 015K4.01 2/20/2006 Page 60 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test 42,

~

, 042 OIO/RO/OK/MODIFIED/COOK 2004 #37/013000 K6.01/(2.7

/ 3.l)//H/3

~~~~~

~~~~~~

~~~~

The following conditions exist:

- Containment pressure instrument Channel #1, 2-PPP-303 (PT-937) declared

- Required actions per 02-OHP-4022-013-011 Containment Instrumentation

- Required Technical Specification Actions have been taken for Channel #1, inoperable.

Malfunction have been completed.

2-PPP-303 (PT-937)

Which ONE of the following describes the REMAINING coincidence for the SAFETY INJECTION ACTUATION and CTS ACTUATION?

Remainina Channels to cause actuation Remaining Channels with INPUT to this function SAFETY INJECTION CTS ACTUATION ACTUATION A?

213 213 B.

113 213 C.

112 1 I3 D.

213 1 I3

~

~

~~

~

ANsWE~R :~

A -

~

~

~~~~~

~~

~

~~~

~~~~

~

The CTS Actuation Bistable is placed in the BYPASSED condition to prevent inadvertent actuation. This changes the remaining channel coincidence to 213 instead of the previous 214. Only 3 channels (Channels 2, 3, & 4) feed the SI Actuation This channel does NOT feed SI so the SI coincidence remains at 213.

B - Incorrect - This channel does NOT feed SI. (True if candidate assumes 4 channels feed SI)

C - Incorrect - This channel does NOT feed SI Actuation. CTS is bypassed. (True if candidate assumes this channel does feed SI and that CTS is tripped)

D - Incorrect - The CTS is placed in BYPASS. (True if candidate knows this channel does NOT feed SI but assumes CTS is tripped) 2/20/2006 Page 61 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test Modified Stem to Fail Channel #1, 2-PPP-303 (PT-937) instead of Channel 3.

Changed answer to A. Also changed distractors B, C, & D (Note that channels feed different actuations)

REFERENCE:

RO-C-AOP-2, Abnormal Operating Procedures - Day 2 pg. 13 and 14 02-OHP-4022-013-011 Containment Instrumentation Malfunction pg. 2 and Att. D LESSON PLAN/OBJ: RO-C-O1100/#9 KA - 013000 K6.01 Engineered Safety Features Actuation System (ESFAS)

Knowledge of the effect of a loss or malfunction of the following will have on the ESFAS:

Sensors and detectors RO/SRO Value - (2.7 / 3.1) CFR - 41.7 / 45.7 SOURCE: INPO # 27671 Cook 1 - 4/29/2004(RO#037/SRO#037)

From 1021 -CALLAWAY97 Original Quest. KA - 013000 K6.01 Engineered Safety Features Actuation System (ESFAS)

Knowledge of the effect of a loss or malfunction of the following will have on the ESFAS:

Sensors and detectors RO-2.7 SRO-3.1 2/20/2006 Page 62 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

43. 043 003/RO/OWNEW//01S000 K4.03K3.9 /4.0)//F/3

-~

~ __

~~

r-~--Fe-Kthe Unit con^^^ RXm-Eble Vault has resulted in loss of equipment control-]

and normal habitability. The Control Room has been evacuated.

Which one of the following would be used to monitor Reactor Power from outside the control room?

A. Source Range - N21 BY Source Range - N23 C. Wide Range - N21 D. Wide Range - N23 ANSWER: B - Source Range N-23 may be monitored from OHP-4025-LS-1.

A - Incorrect - This gamametrics monitor only indicates on the NIS I panel.

C - Incorrect - This gamametrics monitor only indicates on the NIS I panel and the Rod and Flux panel.

D - Incorrect - This gamametrics monitor only indicates on the NIS Ill panel and the Rod and Flux panel.

~

-~

~.

-~

~

. ~~~~

~

I

REFERENCE:

RO-C-01300, Excore Nuclear Instrumentation System pg. 29 LESSON PLAN/OBJ: RO-C-O1300/#5, 17 KA - 01 5000 K4.03 Nuclear Instrumentation System Knowledge of NIS design feature(s) and/or interlock(s) which provide for the following:

Reading of source rangehntermediate range/power range outside control room RO/SRO Value - (3.9 / 4.0) CFR - 41.7 2/20/2006 Page 63 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

44. 044

~~

01 I/RO/OK/NEW//022000

~~~~

~~ 2.!.32/(1.4

~~~

/3.8)//F/3

~

r~--

~ OHP-4021-028-001 Containment Ventilation contains a caution concerning the Loss o q Lower Containment Ventilation.

Which ONE of the following describes the concern and the basis for this concern?

The Loss of Lower Containment Ventilation may...

A. cause NESW Containment Isolation Valves to become pressure bound due to I

temperature changes.

motors heating the Containment atmosphere.

B f cause Phase B isolation signal in about 15 minutes due to Reactor Coolant Pump C. cause the Ice Condenser Doors to open due to pressure differential if the Upper Containment Ventilation units are not also stopped.

D. cause Ice Condenser temperatures to raise to unacceptable levels if additional Coolers are not started.

~~~

ANSWER:

The RCPs continue to provide heat input to the containment atmosphere during a loss of containment cooling. The heat input would cause a rapid rise in containment pressure, resulting in an SI and CTS actuation based solely on a loss of containment cooling.

A - Incorrect - This concern is based on isolation of a segment of the NESW system.

C - Incorrect - The ice condenser door differential pressure caution is contained in the Containment Purge procedure and requires Upper Containment pressure to be less than lower Containment.

D - Incorrect - Ice condenser cooling is provided by the Glycol cooling system which uses NESW to Cool its chillers. A loss of lower containment ventilation should not significantly impact this cooling.

REFERENCE:

OHP-4021-028-001 Containment Ventilation Step 3.5, RO-C-02800, Containment Ventilation System LESSON PLAN/OBJ: RO-C-02800/#6 KA - 022000 2.1.32 Containment Cooling System (CCS)

Conduct of Operations Ability to explain and apply all system limits and precautions.

ROISRO Value - (3.4 / 3.8) CFR - 41.1 0 / 43.2 I 45.1 2 2/20/2006 Page 64 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

45..

045

~~~ 002/ROIOWDIRECT-lNPO/KEWNEE

~~~

~~

-~ -~

2004 - 26772t022000 K3.0X3.0 J 3.3)//H/2

~~~~

~~

.~

~~~

Containment temperature has risen from 1OOOF to 160OF due to a containment cooling malfunction. If the plant is stable at 100% power and there are negligible RCS or containment pressure changes, which one of the following describes the effect of the increase in containment temperature on the pressurizer level indicated by the pressurizer level control channels?

A? Indicated level will be HIGHER than actual level because the reference leg fluid density lowers.

6. Indicated level will be LOWER than actual level because of the elevated containment temperature causes flashing in the reference leg.
c. Indicated level will be HIGHER than actual level because the elevated containment temperature causes flashing in the reference leg.

D. Indicated level will be LOWER than actual level because the reference leg fluid density lowers.

ANSWER: A - Pressurizer Level uses a wet reference leg DP level indicator. This compares the pressure of the full reference leg with the pressure of the actual water in the pressurizer. When these are equal the level indicates 100%. As the temperature in Containment and therefore the reference leg raises the density & weight of the reference leg lowers. This means that the level in the pressurizer will indicate higher for the same initial actual level.

B - Incorrect - The reference leg will not flash since it is exposed to the high pressure of the pressurizer.

C - Incorrect - The reference leg will not flash since it is exposed to the high pressure of the pressurizer.

D - Incorrect - The density does lower but this causes a higher indication.

~~~

~~

~~~

~~

~~~

~

~~

~ -~

~~ ~-

.~ -

~

~~

~~

~

~~ -

~~

REFERENCE:

RO-C-GF27, Sensors and Detectors pg. 51 & 52 LESSON PLANlOBJ: RO-C-GF27/9d KA - 022000 K3.02 Containment Cooling System (CCS)

Knowledge of the effect that a loss or malfunction of the CCS will have on the following:

Containment instrumentation readings RO/SRO Value - (3.0 I3.3) CFR - 41.7 / 45.6 SOURCE: INPO # 26772 Kewaunee, Unit 1 - 2/2/2004 Original Quest. KA - 022000K302 2/20/2006 Page 65 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~

~ 46. 046 M)l/ROIOK/NEW//025000

~~~~~

~~

K6.01K3.4 / 3.6)//H/2 Unit 2 was operating at 95% power, when an operator identified that one of the ice Condenser Intermediate Deck Doors was slightly open and incapable of being fully closed due to Ice Buildup.

Which ONE of the following actions, if any, are required to continue operations at power?(Technical Specifications 3.6.1 1 and 3.6.12 provided)

A. Monitor the ice bed temperature less than or equal to 27OF every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> for a maximum of 2 days.

BY Monitor the ice bed temperature less than or equal to 27OF every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> for a maximum of 14 days.

C. No action is required since the Ice Condenser Inlet Doors are all OPERABLE.

D. Restore the Door to Operable status within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> or be in Mode 3 within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> ANSWER: B - If the Ice Condenser Intermediate deck doors are inoperable then ITS--^^

3.6.12 Action B applies. This requires temperature to be monitored every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> for up to 14 days.

A - Incorrect - The ice Condenser temperature is monitored every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> per ITS 3.6.1 1 and 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> are allowed per ITS 3.6.1 1 if the ice condenser is Inoperable.

C - Incorrect - The Intermediate deck doors are still required to be operable.

D - Incorrect - This is the requirement if a INLET door can not be fully opened.

and Mode 5 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />.

~

~~~~~

~~~

~~

~

~~~~

~~~~~

~~~

~~

~~~~~

~

~

~~~~~~

I

REFERENCE:

ITS 3.6.12 pg. 3.6.12-1, 2,&3 LESSON PLANIOBJ: RO-C-O1000/#12 OHP-4030-STP-030 Rev 35 Attachment Provided - Technical Specifications 3.6.1 1 and 3.6.12 KA - 025000 K6.01 Ice Condenser System Knowledge of the effect of a loss or malfunction of the following will have on the Ice Condenser System:

Upper and lower doors of the ice condenser RO/SRO Value - (3.4 / 3.6) CFR - 41.7 / 45.7 2/20/2006 Page 66 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

47. 047

~~~~ 0 I I IROIOWDIRECTIAUDIT

~-

~~~~~

~~

-~

RO22-BOTH-80/026000 K4.04/Q(3!4. Ij!-Y3 Following a LOCA inside containment in which pressure reached 3.4 psig, the operator notes the following indications:

.Containment pressure is 2.8 psig and lowering slowly;

.Refueling Water Storage Tank (RWST) level.is 23 percent and lowering slowly.

.Panel 105 Drop 2 - "SPRAY ADDITIVE TANK LEVEL AT 4000 Gal" alarm has just actuated.

Assuming NO operator actions, the operator should observe:

- IMO 21 5/225 CTS Pump Suction Valves (1)

- IMO-212/222 Eductor Supply Valves (2)

- and the CTS pumps (3).

(1) Pump Suction (2) Eductor (3) CTS IMO 21 5/225 IMO-212/222 Pumps A.

Closed Closed Tripped BJ Open Open Running C.

Closed Open Tripped D.

Open Closed Running open the Spray additive tank valves. The eductor and suction valves are normally open.

The Spray additive tank alarm at 4000 gal is an expected alarm after the actuation and shows that NaOH is being injected. If the tank reached the Lo-2 alarm the spray additive tank valves would have isolated (Valves close 1" above 10-2). The RWST level of <25% is below the switchover setpoint but the actions to close the suction to the RWST must be performed manually.

A - Incorrect - Pump suction and inductor will not close. Pumps should still be running.

C - Incorrect - Pump suction will not close. Spray Additive tank would still be open.

Pumps should still be running.

D - Incorrect - Spray Additive tank and eductor would still be open.

2/20/2006 Page 67 of 146

-~

~

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

1 -0HP-4024.105, Annunciator #lo5 Response: Containment Spray, Drop 3 and 23; SOD -00901-001, Containment Spray and Hydrogen Recombiners, RO-C-00900 pg 17.

LESSON PLAN/OBJ: RO-C-00900/#11 KA - 026000 K4.04 Containment Spray System (CSS)

Knowledge of CSS design feature(s) and/or interlock(s) which provide for the following:

Reduction of temperature and pressure in containment after a LOCA by condensing steam, to reduce radiological hazard, and protect equipment from corrosion damage RO/SRO Value - (3.7 I4.1) CFR - 41.7 (spray)

SOURCE: AUDIT R022 Both 80 (067/72)

Original Quest. KA - SYS 026 A3.01 Containment Spray System (CSS)

- Ability to monitor automatic operation of the CSS, including: Pump starts and correct MOV positioning 2/20/2006 Page 68 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test The Unit Supervisor directs you to verify or restore power so a hydrogen recombiner may be run.

Which ONE of the following actions is required to enable the associated Hydrogen Recombiner to be operated?

A:,

Verify that bus T11 C has energized 600V Bus 11 C and MCC-1 -EZC-C for (Train A)

Hydrogen Recombiner Number 2.

B. Verify that bus T11 C has energized 600V Bus 1 1 C and Close the 1 1 AC crosstie to supply power to Bus 11A and MCC E X - A for (Train B) Hydrogen Recombiner

48. 048 OIO/RO/OK-REPEAT/DlRECT/COOK 2004 #44/028000 K2.01/(2.5/ 2.8)//H/3

~

~

~

~

~

~~~~~~

~

~~~~

~.

~~

Unit 1 has experienced a LOCA and Loss of Offsite power.

The following conditions exist:

- Emergency Diesel Generator 1 AB failed to start.

- Emergency Diesel Generator 1 CD has started and loaded as designed,

- Power has been restored to the Reserve Aux Transformers.

- No buses have been energized from the RATS.

I I

C. Energize RCP Bus 1 B from the RAT to supply power to 600V Bus 11 BMC for (Train 1 B) Hydrogen Recornbiner Number 1.

D. Energize RCP Bus 1 C from the RAT to supply power to 600V Bus 1 1 CMC for (Train ANSWER: A -Hydrogen Recombiner #1 is powered form MCC-1-EZC-B and Hydrogen Recombiner #2 is powered form MCC-1 -EZC-C.

B - Incorrect - Hydrogen Recombiner #1 is powered form MCC-1-EZC-B C - Incorrect - Hydrogen Recombiner #1 is powered form MCC-1-EZC-B D - Incorrect - Hydrogen Recombiner #2 is powered form MCC-1 -EZC-C I

A) Hydrogen Recornbiner Number 2.

~~~~

~

~~~~~~~~

~~~~~~~~

~~~~

~~~~~

~~~~~~~

2/20/2006 Page 69 of 146

~

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

SD-00900 Containment Spray and Hydrogen Recombiner System Description pg. 32 LESSON PLAN/OBJ: RO-C-00900/#9 KA - 028000 K2.01 Hydrogen Recombiner and Purge Control System (HRPS)

Knowledge of bus power supplies to the following:

Hydrogen recombiners RO/SRO Value - (2.5 / 2.8) CFR - 41.7 SOURCE: INPO # 27678 Cook 1 - 4/29/2004(RO#044/SRO#044)

Original Quest. KA - 028000 K2.01 2/20/2006 Page 70 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~~ 49.

~~ 049 03 I/RO/OWNEW//029000 p~~~~~

~ ~ p _. ~

2.4.31/(3.3

/3.4)//H/3

.~

p

~

~

_ _ ~

The following conditions exist:

- Unit 1 was in Mode 1.

- A Containment Pressure Relief was in progress with the following lineup:

1-VCR-107, Cntmt Press Relief Valve IC -OPEN 1-VCR-207, Cntmt Press Relief Valve OC - OPEN 1 -HV-CPR-1, CNTMT Press Relief Fan - RUNNING

- An external failure alarm on VRS-1201, Upper Containment Normal Range Monitor, occurs.

Which ONE of the following describes the required operator response for the Containment Pressure Relief System due to the failure alarm?

A:,

Verify 1 -VCR-207 has automatically closed, 1 -HV-CPR-1 has automatically tripped, and manually close 1-VCR-107.

B. Verify 1 -VCR-107 has automatically closed, manually trip 1 -HV-CPR-1, and manually close 1 -VCR-207.

C. Verify 1 -VCR-207 and 1 -VCR-l07 have automatically closed and 1 -HV-CPR-1 has automatically tripped.

D. Initiate an eSAT to address the VRS-1201 failure. The release may be continued as ANSWER: A - VRS-12Olckse~he Outside~Co~ta~~meniisolat%npValve VCR-201 and trips the 1-HV-CPR-1, CNTMT Press Relief Fan. VCR-107 is closed by the VRS-1101 channel.

B - Incorrect - Actions for failure of the VRS-1101 channel.

C - Incorrect - VCR-107 is closed by the VRS-1101 channel. This would be the response if both channels sensed a high radiation condition.

D - Incorrect - The release will automatically terminate (VCR-207 8, HV-CPR-1). The release may be restarted after appropriate actions have been taken.

long as VRS-1101 is operable.

~.

~~

~

~~~~~

~

2/20/2006 Page 71 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

SOD-I 350-001, Radiation Monitoring System; 12-OHP-4021-139 #2 LESSON PLAN/OBJ: RO-C-02800 / #14 KA - 029000 2.4.31 Containment Purge System (CPS)

Emergency Procedures/Plan Knowledge of annunciators alarms and indications, and use of the response instructions.

RO/SRO Value - (3.3 / 3.4) CFR - 41.1 0 / 45.3 2/20/2006 Page 72 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~. 50.

~~~

050 01 I/RO/OWNEW//035000

~

~~~

~ -~

~

~~

~

~

A4.01/(3.7 /3.6)/R1/2 The following conditions exist:

. Unit 1 is at 100% power and stable.

-Steam Generator Level Controls are in AUTOMATIC.

- Steam Generator #12 Steam Flow Channel 1, 1 -MFC-I 21, is selected to the Steam Generator Level Control System.

A blown fuse causes 1-MFC-121 to fail offscale low.

Which ONE of the following describes the expected plant response?

The Steam Generator Level Control system will...

A. initially lower feed flow and then slowly return #12 SG level to approximately BY automatically transfer the # 12 FW Regulating Valve Controller to Manual to program level.

maintain the current valve position.

C. initially raise feed flow and then slowly return #12 SG level to approximately program level.

D. lower feed flow to #12 SG to 0 pph, resulting in a Reactor Trip.

ANSWER: B - A~sudden failure offscale will cause the Taylor Controller to shift to manual at the current position.

A - Incorrect - The FRV Controller will shift to manual. This is the response to a slow Steam Flow failure.

C - Incorrect - The FRV Controller will shift to manual. This is the response to a slow FW Flow failure.

D - Incorrect - The FRV Controller will shift to manual. This would be the response to a slow failure without a level input.

~~~~~~~

~~~~

..~

~~~

~~

~

~~~~

~~

~

~

REFERENCE:

SD-05100, Steam Generator System Description pg. 20-21, RO-L-ES07, Control Room Controllers and Recorders LESSON PLAN/OBJ: RO-C-05100 / #9 KA - 035000 A4.01 Steam Generator System (S/GS)

Ability to manually operate and/or monitor in the control room:

Shift of S/G controls between manual and automatic control, by bumpless transfer RO/SRO Value - (3.7 / 3.6) CFR - 41.7 / 45.5 to 45.8 2/20/2006 Page 73 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test A. Mounted downstream of SG PORVs. Energized ONLY when the PORVs are open.

Which ONE (1)ofhefollowingdescribesthe location and use of MRA-1600/1700 Steam Generator PORV Monitors?

B. Mounted upstream of SG PORVs. Energized ONLY when the PORVs are open.

C. Mounted upstream of SG PORVs. Provide accurate readings of steam line radiation ONLY when the PORVs are open.

Dr' Mounted downstream of the SG PORVs. Provide accurate readings of steam line 1

~

~~~~~~

~~

~

radiation ONLY when the PORVs are open.

~

~~~~~~~~

~

~~~~~~~~

~~~~~~~

SOURCE: INPO # 28083 Robinson 2 - 9/27/2004 Original Quest. KA - 039 K1.09 1 2/20/2006 Page 74 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

52. 052 002/RO/OWNEW//041000

~

K1.02/(2.7 /2.9)//H/3 The following plant conditions exist on Unit 1 :

-The reactor is critical at 7% power just prior to rolling the turbine.

- Manual FW control is maintaining SG Levels.

- RCS temperature is being controlled by steam dumps in automatic in the Steam Pressure Mode.

UPC-101 Steam Header Pressure transmitter, then fails to 0 psig.

With NO operator action, which of the following statements describes the resulting SG Level response?

Steam Generator level will initially...

A? lower due to shrink and then raise as RCS temperature raises.

B. raise due to swell and then lower due to the higher steam release rate.

C. lower due to shrink and then raise due to higher FW flow at the lower pressure.

D. raise due to swell and then lower due to lower FW flow at the high pressure.

ANSWER: A -The Steam Dumps will be trying to maintain Steam Line pressure.

When the actual pressure fails low the dumps will close, causing SG pressure to be higher. This will cause an initial shrink followed by level rising as the RCS temperature raises.

6 - Incorrect - The failure will cause steam dumps to close.

C - Incorrect - The SG will shrink but due to higher pressure D - Incorrect - The SG will shrink from the higher pressure.

~~~~~~~~~

~~~~~~~~~

~

~

~~~

~

~

~~~

~

~

~~~~~~

~

~~~~~

~

REFERENCE:

RO-C-05200 Steam Dump System LESSON PLAN/OBJ: RO-C-05200/#7 KA - 041 000 K1.02 Steam Dump System (SDS) and Turbine Bypass Control Knowledge of the physical connections and/or cause-effect relationships between the SDS and the following systems:

SIG level RO/SRO Value - (2.7 / 2.9) CFR - 41.2 to 41.9 / 45.7 to 45.8 2/20/2006 Page 75 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

53. 053

~~~~ O05/RO/OWMODIFIED/O1055C0007-2/056M)0

~~

~

~

~

A2.04/(2.6 / 2.8)/M3.

The following plant conditions exist:

- Unit 2 is at 9% power.

- East Main Feedwater Pump is supplying main feedwater to the SGs.

- AFW pumps are aligned in Auto.

- All operating condensate booster pumps trip.

Which ONE of the following describes the system response and required operator action?

'A. MFPs--Immediate Trip MDAFW Pumps Start from MFP trip Reactor Trip--On low low SG level Enter OHP-4023-E-0, Reactor Trip or Safety Injection B. MFPs--Immediate Trip MDAFW Pumps Start & Turbine Trips from AMSAC Enter OHP-4022-001-002, Loss of Load (Load Rejection)

CY MFPs--Trip after 5 sec. Delay MDAFW Pumps Start from MFP trip Reactor Trip--On low low SG level Enter OHP-4023-E-0, Reactor Trip or Safety Injection D. MFPs--Trip after 5 sec. Delay MDAFW Pumps Start & Turbine Trips from AMSAC Enter OHP-4022-001-002, Loss of Load (Load Rejection)

~

~.

~~

~

~~~~~

~~~~~~~

~

ANSWER: C - The MFPs will trip after FW suction pressure has lowered to 4 8 0 psig for 5 seconds. The trip of the Main FW pumps will cause the MDAFW pumps to start.

The delayed trip of the FW pumps and the current power level will cause SG levels to Lower to the low low SG level reactor trip setpoint. After the reactor is tripped E-0 is entered.

A - Incorrect - The FW pumps will not trip immediately.

B - Incorrect - The FW pumps will not trip immediately. AMSAC will not actuate since power is not >40%.

D - Incorrect - AMSAC will not actuate since power is not >40%.

2/20/2006 Page 76 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test Modified to address Required Operator Action in stem. Added AMSAC to distracters and added procedure choices.

REFERENCE:

2-OHP 4021.001.006, Power Escalation LESSON PLAN/OBJ: RO-C-05500/#6 KA - 056000 A2.04 Condensate System Ability to (a) predict the impacts of the following malfunctions or operations on the Condensate System and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations:

Loss of condensate pumps ROISRO Value - (2.6 12.8) CFR - 41.5 143.5 / 45.3 / 45.1 3 Original Question Source : Master Bank 01 055COOO7-2 Original KA 035 A4.01 2.712.9 EXAM/QUIZZES: R018PRAC-I ; R015 NRC EXAM; R020NOP1 M; R024SYS03 LESSON PLAN/OBJ: RO-C-05500/#6;

REFERENCES:

2-OHP 4021.001.006, "Power Escalation 2/20/2006 Page 77 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

54. OS4 003/RO/OWD1RECT/O105SC0008-5/0S9000 AI.O7/(2.5 /2.6)//w3.

~

~~~~

~~~

~

~~~~~~

If Turbine Bypass Header Pressure Transmitter UPC-101 fails HIGH during normal plant operation the MFP Speed Control System will generate a Delta-P signal (Assume the failover circuit does NOT function)

(1) than required, causing the main feed pump(s) to (2) 0 (2)

A.

larger speed up

6.

larger slow down C? smaller speed up D. smaller slow down ANSWER: C -The Main FW Pump Speed control compares the UPC-101 steam header pressure to the FW pump Discharge pressure. The speed control attempts to maintain the Main FW Pump speed such that the FW header to Steam Header DP is on Program. When the Steam Pressure fails high, it will appear that a smaller DP exists which will raise FW pump speed to try to raise FW pump Discharge header pressure.

A - Incorrect - Steam to FW discharge pressure DP will be lower.

B - Incorrect - Steam to FW discharge pressure DP will be lower. Response if Steam pressure failed low.

D - Incorrect - The controller will raise FW pump Speed.

~~~~

~

~~

.~

~~

~

REFERENCE:

SOD-051 00-003 LESSON PLAN/OBJ: RO-C-05500/#8 KA - 059000 Al.07 Main Feedwater (MFW) System Ability to predict and/or monitor changes in parameters (to prevent exceeding design limits) associated with operating the MFW System controls including:

Feed Pump speed, including normal control speed for ICs RO/SRO Value - (2.5 / 2.6) CFR - 41.5. / 45.5 SOURCE: Master Bank 01055COOO8-5 Original Quest. KA - 059 K4.05 (2.512.8)

EXAM/QUIZZES: Q2404V; R2324B-A3B; R023SYS3; R024SYS03 2/20/2006 Page 78 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~ 55. 055

~~~~ 001fRO/OK/DIRECT-INPO/BYRON

~.

2003 - 26387/061000 K5.01K3.6 /3.9)/@/3 Following a reactor trip with NO SI required, the operators are performing the immediate actions of OHP-4023-E-0, Reactor Trip or Safety Injection Which of the following describes the basis for the following Step 4 RNO actions?

(1) Lower AFW flow to < 450,000 pph (2) Maintain AFW flow >240,000 pph until minimum S/G water level is obtained A. (1) Limit runout of the Aux Feed pumps.

(2) Ensure enough feedwater flow for decay heat removal.

B. (1) Limit runout of the Aux Feed pumps.

(2) Ensure enough flow for Aux Feed Pump protection.

(2) Ensure enough feedwater flow for decay heat removal.

C?' (1) Limit overcooling of the RCS.

D. (1) Limit overcooling of the RCS.

ANSWER: C - - If Si is not actuated and it is determined that an Si is not required AFW flow is reduced to limit the RCS cooldown due to excessive feed flow while ensuring that adequate AFW flow is maintained above the required value for decay heat removal until the minimum required SG narrow range level is restored. The intent of this action is to reduce excessive AFW flow to near the discharge flow of two MDAFW pumps at SG design pressure in a prompt manner prior to transitioning to ES-0.1 to allow for stabilizing RCS temperature near its normal no-load value in a timely manner. After transitioning to ES-0.1 the operators will follow the appropriate guidance in ES-0.1 for controlling AFW flow following a reactor trip.

(2) Ensure enough flow for Aux Feed Pump protection,

~

~

~

~ -~

~

~

~

~~~~~~

.~

~~

~~

~

~

~

~~~~~~

~

~

~~

~~~

~

A - Incorrect - AFW pumps are protected from runout through the flow retention system.

B - Incorrect - AFW pumps are protected from runout through the flow retention system. The EL0 valves cycle automatically on signals from their respective flow controllers to ensure AFW pump minimum flow.

D - Incorrect - The EL0 valves cycle automatically on signals from their respective flow controllers to ensure AFW pump minimum flow.

2/20/2006 Page 79 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

12-OHP-4023-E-0, Reactor Trip or Safety Injection Background Step 4 PS. 16 LESSON PLAN/OBJ: RO-C-EOP03/#19 KA - 061 000 K5.01 Auxiliary / Emergency Feedwater (AFW) System Knowledge of the operational implications of the following concepts as they apply to the AFW System:

Relationship between AFW flow and RCS heat transfer RO/SRO Value - (3.6 / 3.9) CFR - 41.5 / 45.7 SOURCE: INPO # 26387 Byron I - 12/10/2003 Original Quest. KA - 061000.A3.02 2/20/2006 Page 80 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

56. 056 02 I/RO/OWMODIFIED/O

~~~~

I082CO

~~~~~~~~~~

108-1/062000 A2.0/2.7/3.0~~..,....~

~~

~~~~

~~~

~~ -

~

The following conditions exist:

- Unit 1 is at 38% power.

- RCP busses 1A and 1 B are energized from Reserve power

- Bus T11A voltage drops to 11 2 V indicated for 2 minutes Which ONE of the following describes the plant response and the required operator actions?

A. RCP bus-tie breakers to buses T11A and T i 1 B open. Verify Reactor Trip and go to 01 -0HP-4023-E-0, Reactor Trip or Safety Injection.

B. Reserve Feeder breakers to RCP buses 1A and 1 B open. Verify Reactor Trip and go to 01 -0HP-4023-E-0, Reactor Trip or Safety Injection.

T11A and T11 B and raise RAT feed voltage per 01 -0HP-4021-082-026, Operation of the Load Tap Changer.

D. RCP buses 1A and 1 B fast transfer to the Auxiliary Transformer 1AB. Verify T11A and T11 B remain energized and raise RAT feed voltage per 01 -0HP-4021-082-026, Operation of the Load Tap Changer.

C!, RCP bus-tie breakers to buses T11A and T11 B open. Verify 1 AB DG energizes

~~~

~~~~~~~~~~~~~~~

~

~

~

~

~

~~~~~~

~~~~

~~~~~~~

~

~

~

ANSWER: C - A Vital bus Undervoltage condition of 1 13 V will energize 62-1 T11 A.

After a 11 1 Second delay it will open T11 A9 and T11 B1 causing T11 A and T11 B to lose power. This will cause the EDG to start and energize T11A and T11 B. The RAT voltage should be raised using the Load Tap changers (this should have occurred automatically) as directed per 01 -4021 -082-026.

A - Incorrect - This does Not cause a Reactor trip.

B - Incorrect - The RCP Busses will remain energized and will only send an undervoltage signal (2/4 cause RX trip) when indicated voltage on the RCP bus is <88 volts.

D - Incorrect - The RCP buses will not transfer to the UATs. (They do auto transfer from UAT to RAT).

2/20/2006 Page 81 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test Modified by adding vital bus voltage and requesting actions required in the stem.

Distracters all changed.

REFERENCE:

01 -0HP-4024-121, Annunciator #121 Response, Drop 78 Train B Aux Buses Undervoltage pg. 168 LESSON PLANIOBJ: RO-C-082011#6 KA - 062000 A2.08 A.C. Electrical Distribution System Ability to (a) predict the impacts of the following malfunctions or operations on the A.C.

Distribution System and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations:

Consequences of exceeding voltage limitations ROISRO Value - (2.7 13.0) CFR - 41.5 143.5 145.3 145.13 SOURCE: Cook Master Bank 01082CO108-1 Original Quest. KA - 062 K I.04 A.C. Electrical Distribution System Knowledge of the physical connections andlor cause-effect relationships between the A.C. Distribution System and the following systems:

Offsite Sources EXAMIQUIZZES: R911516; R01825; 99SEIR07; 99SEIR20; R02002; R020SR01; RQ2605C; RQ2605D; R022SYSREVIEW; R023SYS1 R; R023SYS5; R023SYSCOMP; RQ2807E; RQ2807A; R024SYS04 RO-3.7 SRO-4.2 2/2012006 Page 82 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~ 57.

~~~~~~

OS7

~.

~~~~~~~~~ 002/RO/OK/DIRECT/O1082C0303-2/062000

~

A3.04/(2.7 I 2.9)//w3

~~~

The operator incorrectly opens the breaker labeled "7.5 KVA Static Inverter Channel IV" on 250 VDC distribution panel "MCAB". The operator realizes the mistake and immediately recloses the breaker.

Which ONE of the following describes the effect of these actions, if any?

A. The alternate power source to the CRlD Inverter will be lost when the breaker is reclosed. The CRlD will transfer to the 120 VAC from the Regulating Transformer.

6. The alternate power source to the CRlD Inverter will be lost. No automatic action will occur when the breaker is reclosed. The auto transfer lockout must be reset at the inverter.

C? The normal power source to the CRlD Inverter will be lost so it will auto transfer to the alternate source. When the breaker is reclosed, it will auto transfer to the normal source.

D. The normal power source to the CRlD Inverter will be lost so it will auto transfer to the alternate source. When the breaker is reclosed, the auto transfer lockout must be reset at the inverter.

~~~~~~~

~~~~~

~

~~

~~~~~~~~~

~

~

~

~

~

~

~~~

~~

~

~

ANSWER: C - The static transfer switch provides a virtual zero time transfer to the alternate source in case of inverter failure. Thirty seconds after the static switch transfer event ceases and all system parameters are normal, the static switch automatically re-transfers the load to the inverter, without power interruption.

A - Incorrect - The Alternate source will not be lost. The normal DC supply will be restored and the Inverter will re-transfer to the normal source.

B - Incorrect - The Alternate source will not be lost. The normal DC supply will be restored and the Inverter will re-transfer to the normal source.

D - Incorrect - The normal DC supply will be restored when the breaker is closed and the Inverter will re-transfer to the normal source.

2/20/2006 Page 83 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

RO-C-08203, Instrumentation Electrical System pg. 19-20 LESSON PLANIOBJ: RO-C-O8203/#3e, #39 A.C. Electrical Distribution System Ability to monitor automatic operation of the A.C. Distribution System, including:

Operation of inverter (e.g., precharging synchronizing light, static transfer)

RO/SRO Value - (2.7 12.9) CFR - 41.7 I 45.5 Original Question Source: Bank 01 082CO303-2 Original KA - 063 K4.01 (2.7 I 3.0)

EXAM/QUIZZES: ROC1 9C2; 99SEIR08; R02001 ;R020SR01; R022EOP8A ;

R023SYS2; R023AOP2; R024SYSAUX

REFERENCES:

DC Aux One-Line Drawing OP2-1112060-8 KA - 062000 A3.04 212012006 Page 84 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

58. 058 002/RO/OK/Z)IRECT/ASI 1-21/063000 K4.0406

/2.9)l/H/2

~

~~~~~

~~~

~~

~~~~~

Unit 1 has experienced a Reactor Trip and Safety Injection. After stabilizing the plant, the oDerator identifies that Annunciator Panel 11 5 Drop 57 Trains A & B N Train Battery Chg De-Energized is lit. The Train A Charger was in service prior to the trip.

Which ONE of the following describes the system or operator response necessary to restore the battery charger to service?

A. The standby charger will automatically pick up the load and battery when sufficient draw down of the battery has occurred.

B. The charger will come back on when sufficient draw down of the battery has occurred.

C. This charger is locked out and cannot be re-energized. Therefore, it is necessary to put the opposite train charger in service by placing its control box switch to Auto.

DY Turn the battery charger control box switch on the in-service battery charger to Off ANSWER: D - Following a load shed or safety injection (SI), the battery chargers are disconnected from their respective 600V AC power supply. When this occurs, the Charger Switch must be moved to Off and then back to Auto to restore the charger to the battery.

A - Incorrect - Neither charger will automatically re-energizehe-connect to the battery.

Manual acton is required.

B - Incorrect - Neither charger will automatically re-energizehe-connect to the battery.

Manual acton is required.

C - Incorrect - The train a charger may be restored by resetting its control switch.

01 -0HP-4024-115 Drop 57 and then back to Auto.

~~~~

~~~~~

~

~

~

~

~~~~

~~~

REFERENCE:

SD-05600 AUXILIARY FEEDWATER SYSTEM pg. 33, LESSON PLAN/OBJ: RO-C-08204/#3 KA - 063000 K4.04 D.C. Electrical Distribution System Knowledge of D.C. Electrical System design feature(s) and/or interlock(s) which provide for the following:

Trips RO/SRO Value - (2.6 / 2.9) CFR - 41.7 ORIGINAL Question Source : Bank AS11-21 EXAMIQUIZZES: AE26AE1; U023M22 2/20/2006 Page 85 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~

59. 059 002/RO/OWDIRECT-INPO/IP3

~

2003 - 23362/064000 A1,08/(3.1 / 3.4)//F/3 The following conditions exist:

- The Plant is operating at 100% power.

- 2CD EDG is started for surveillance testing.

Which ONE (1) of the following describes how a reverse power condition is prevented when closing the EDG output breaker?

A. Ensure running and incoming voltages are matched prior to closing the output B. Ensure running and incoming currents are matched prior to closing the output breaker.

breaker.

C?' Ensure synchroscope is rotating slowly in the 'FAST' (clockwise) direction prior to closing the breaker.

D. Ensure running and incoming frequencies are matched prior to closing the output ANSWER: C - The procedure requires the Operator to ensure that the synchroscope is rotating slowly in the 'FAST' (clockwise) direction prior to closing the breaker. This causes the DG to be slightly faster than the Grid causing it to pick up some load thus preventing a reverse power trip.

A. - Incorrect. Ensuring voltage is matched ensures no large reactive current flow on breaker closure.

B. - Incorrect. Running and incoming currents being matched would make no difference, as actual current flow is transferred by motive force.

D. - Incorrect. Matching frequency may actually increase the chance of reverse power because the incoming machine will take less load on parallel

REFERENCE:

02-OHP-4021-032-001 Attachment 2 DG2AB Operation on Safeguards Buses Section 4.2 breaker

~~

~~~~~

~

~~~~~~

~~~~~~~~

~~~~

~

~~~~~

~

LESSON PLAN/OBJ: RO-C-03200/#10 KA - 064000 Al.08 Emergency Diesel Generator (ED/G) System Ability to predict and/or monitor changes in parameters (to prevent exceeding design limits) associated with operating the ED/G System controls including:

Maintaining minimum load on ED/G (to prevent reverse power)

RO/SRO Value - (3.1 / 3.4) CFR - 41.5 / 45.5 SOURCE: INPO # 23362 Indian Point 3 (Unit) - 3/10/2003 Original Quest. KA - 064.A1.08 2/20/2006 Page 86 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

60. 060 021/RO/OWDIRECT/AUDIT

~~~~

R023.~

4#99/068000 A3.02/(3.6/3.6)//F/3~.

~

~~

r-~~.

Which ONE of the following actions, if any, will occur due to a HIGH rad alarm on 1

monitor RRS-1001, Liquid Radwaste Effluent Line?

A. Alarms at WDS and Control Rooms only - no automatic actions.

BY RRV-285, liquid waste disposal effluent discharge header shutoff valve closes.

C. RRV-286 or RRV-287 liquid waste effluent to header ClRC water discharge header D. RRV-284, liquid release control valve closes.

shut off valve closes.

~.

~

~~

~~

~

~~~~~

~~

~

~~~

~~

~

~

ANSWER: B -The high alarm on RRS-1001 will cause RRV-285 to close and also trip the WECT and monitor tank pumps.

A - Incorrect - The High Level causes the isolation. The alert level just gives an alarm.

C - Incorrect - RRV-286 or 287 are used to select which unit to discharge to and will close on loss of CW flow. These valves do not auto close on High radiation.

D - Incorrect - RRV-284 controls the release flow rate but does not isolate on High Radiation.

REFERENCE:

12-OHP 4024.139 Drop 16 LESSON PLAN/OBJ: RO-C-O1350/#4 KA - 068000 A3.02 Liquid Radwaste System (LRS)

Ability to monitor automatic operation of the Liquid Radwaste System, including:

Automatic isolation ROlSRO Value - (3.6 / 3.6) CFR - 41.7 / 45.5 SOURCE: R023 Audit (RO# 099/SRO# N/A)

From Bank AS06-22 Original Quest. KA - SYS 068 A3.02 (3.6/3.6)

EXAM/QUIZZES: AE26AE1; AE26AE2; AE26AE3; AE26AE4; AE26AE5; U022FNL; AE2703V; AE2703A; AE2703C; AE2709AC 2/20/2006 Page 87 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~ 61. 061 OIOIROIOK-REPEAT/DIRECT/COOK 2004 #87/073000K3~01/(3.6 / 4.2)//H/3

~

~~

~

Unit 1 is in Mode 5 following a refueling outage. The Containment Purge System was operating in the VENTILATION MODE with the following lineup:

Purge Supply Fan HV-CPS RUNNING Purge Exhaust Fan HV-CPX RUNNING Purge Supply to Upper Containment VCR-105 and VCR-205 OPEN Purge Exhaust from Upper Containment VCR-106 and VCR-206 OPEN Following a HIGH alarm on ERS-1401, Lower Containment Radiation Monitor, the Containment Purge System is aligned as follows:

Purge Supply Fan HV-CPS RUNNING Purge Exhaust Fan HV-CPX RUNNING Purge Supply to Upper Containment VCR-105 and VCR-205 OPEN Purge Exhaust from Upper Containment VCR-106 and VCR-206 OPEN Which ONE of the following describes the required operator actions?

A. Stop the Containment Purge and declare Containment Ventilation Isolation inoperable.

BY Stop the Containment Purge and notify Radiation Protection, C. Continue the Purge as long as VRS-1101, Containment Normal Range Area Radiation Monitor still indicating as expected.

D. Continue the Purge as long as VRS-1505, Auxiliary Building Ventilation Noble Gas Activity Monitor still indicating as expected.

~

~~

~

~~~~~~~~

. ~

~~~~~~~~~~

~~~~~~~

~~~~~

~~~~~~~~~

ANSWER:B -

When the Containment Purge system is operating in the Ventilation Mode, the automatic isolation signals are blocked. The procedure requires the Purge to be stopped and radiation protection notified.

A - Incorrect - When the Containment Purge system is operating in the Ventilation Mode, the automatic isolation signals are blocked.

C - Incorrect - The procedure requires the Purge to be stopped and radiation protection notified.

D - Incorrect - The procedure requires the Purge to be stopped and radiation protection notified. (This monitor is required per ODCM) 2/20/2006 Page 88 of 146

DC Cook 2006 NRC ILT Wrlhen Examination 2006 SRO Submitted Test

REFERENCE:

01 -0HP-4021-028-005, Operation of the Containment Purge System (Ventilation Mode) pg. 29 LESSON PLAN/OBJ:RO-C-02800 / #9 KA - 073000 K3.01 Process Radiation Monitoring (PRM) System Knowledge of the effect that a loss or malfunction of the PRM System will have on the following:

Radioactive effluent releases RO/SRO Value - (3.6 / 4.2) CFR - 41.7 / 45.6 SOURCE: INPO # 27721 Cook 1 - 4/29/2004(RO#O87/SRO#NA)

Modified from COOK02-086-1 Original Quest. KA - 029000 2.1.23 Containment Purge System (CPS)

Conduct of Operations Ability to perform specific system and integrated plant procedures during all modes of plant operation.

RO-3.9 SRO-4.0 2/20/2006 Page 89 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~ 62. 062 002RO/OK/DIRECT-INPO/lNT

. BEACH

~~~

1999-2836/076000 2.1.33/(3.4 / 4.0)//H/3 -~

~~

~~~~

During a surveillance test on the Unit 1 train A SI, the East Essential Service Water (ESW) pump failed to receive an auto-start signal. The pump started normally in manual. Which one of the following describes the operability and Technical Specification (TS) applicability associated with the Unit 1 East ESW pump?

The Unit 1 East ESW Pump is...

A. still operable because it can still be manually startedand a service water TS LCO action statement would not be entered.

BY inoperable and a service water TS LCO action statement would be entered because the auto start is required to be operable.

falls below 40 psig and a service water TS LCO action statement would not be entered.

C. still operable because it will start automatically if the pumps discharge pressure D, inoperable and a service water TS LCO action statement would be entered only if the associated Unit 2 ESW pump is also inoperable or the crossties are closed.

ANSWER: B - Technical Specification 3.7.8 Essential Service Water Systems, SR 3.7.8.3 requires the auto start function of the ESW pump for operability.

A - Incorrect - Auto start is required for operability.

C - Incorrect - While the pump may start at 40 psig the SI auto start would also be required for operability.

D - Incorrect - If the crossties are open then the LCO action statement also applies to Unit 2.

~

~

~~

~

~

~

~~~~

~~

~~~~~

~~ -

~~

-~.~

~.

2/20/2006 Page 90 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

Technical Specification 3.7.8 Essential Service Water Systems, SR 3.7.8.3 LESSON PLAN/OBJ: RO-C-O1900/#15 KA - 076000 2.1.33 Service Water System (SWS)

Conduct of Operations Ability to recognize indications for system operating parameters which are entry-level conditions for technical specifications.

RO/SRO Value - (3.4 / 4.0) CFR - 43.2 / 43.3 / 45.3 SOURCE: INPO # 2836 Point Beach 1 - 8/2/1999 Original Quest. KA - 076000.G2.2 2/20/2006 Page 91 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

63. 063

~~~~~~~ 003/RO/OK/DIRECT/O1020C0012-2/076000

~

~~~

K2.04K2.5 / 2.6)//w2

~~

~

~

~~

~

~

~~

~

~~~~~~~~

Unit 2 is operating at power with the South NESW Pump supplying the Unit 2 and Miscellaneous Header Heat Loads. An electrical fault on Transformer TR21 B causes the loss of Bus 21 B. The NESW System response to this event would be to:

A9 start the Unit 2 North NESW Pump due to low header pressure B. start the Unit 1 South NESW Pump due to load shed.

C. open the Miscellaneous Header cross connect valves on load shed D. continue operating as before the loss, except that the North NESW pump would noi be available.

~~~

~

~~~

~

~~~~~~~~~~~~~

~

~

~~

~.... ~.~

~

~~

ANSWER: A -The South NESW pump is supplied from Bus 21B. On a loss of power the Unit 2 North NESW pump will auto start on Low NESW Header Pressure.

B - Incorrect - The Unit 1 NESW pump will not start due to a loss on Unit 2.

C - Incorrect - The Miscellaneous header Cross connect valves do not automatically reposition.

D - Incorrect - The south NESW pump is supplied from bus 21 B. The North pump doe not lose power.

REFERENCE:

RO-C-02000, Non-Essential Service Water LESSON PLAN/OBJ: RO-C-02000/#12 KA - 076000 K2.04 Service Water System (SWS)

Knowledge of bus power supplies to the following:

Reactor building closed cooling water RO/SRO Value - (2.5 / 2.6) CFR - 41.7 SOURCE: Master Bank 0102OCOO12-2 Original Quest. KA - 076 K6.04 (2.112.2)

EXAM/QUIZZES: R921717; R019C1; RQ2804E LESSON PLAN/OBJ: ;

REFERENCES:

SD-02000 2/20/2006 Page 92 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~~~ 64. 064

~~

~ 01

~ I/RO/OK/DIRECT/AUDIT

~

~

~

~~~~~~~~~~~

R022 #18/078000 A3.01/(3.1

~_______________~

/3.2)//F/3

~~

~

~

~

~

~

~~~~

~~~~~

Which ONE of the following describes the normal operation of the Plant and~control Ail systems?

A. The standby Plant Air Compressor will automatically start at 90 psig in the ring header.

B?' Control Air pressure lowering to 90 psig in the wet air receiver will start the Control Air Compressor.

C. The operating Plant Air Compressor cycles on and off between 93 and 100 psig when operating in automatic.

D. The Unit 1 Control Air header will automatically cross connect to the Unit 2 Control Air header if the Unit 1 Control Air Compressor fails to maintain header pressure above 85 psig.

~

~

~

~~~~~~~

~

.~

~

~~

~

ANSWER: 6 - At 90 psig in the Control air systems the Control air compressors start to supply their respective units.

A - Incorrect - The PAC will auto start at 95 psig.

C - Incorrect - The CAC will cycle between 93 and 100 psig.

D - Incorrect - The Plant Air Header Isolates at 85 psig.

REFERENCE:

SD-06400 LESSON PLAN/OBJ: RO-C-06401/#4 KA - 078000 A3.01 Instrument Air System (IAS)

Ability to monitor automatic operation of the IAS, including:

Air pressure RO/SRO Value - (3.1 / 3.2) CFR - 41.7 / 45.5 SOURCE: Audit R022 #18 Original Quest. KA - SYS 078 A3.01 2/20/2006 Page 93 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

65. UfrS OUI/RO. OK. DIRI~~T-INPO/MII.I.S'I'O~l:?11114-27098/103~1(111 K4.06/(3.

... - I. / 3.7J//F,3 With the plant at 100% power, an inadvertent'containment Isolation Phase A occurs.

The reactor has NOT tripped and Safety Injection has NOT actuated.

How has the Phase A signal affected the Chemical and Volume Control System Containment paths?

A? Only the Letdown Containment Isolation Valves (QCR-300/301), Letdown Orifice Isolation Valves (QRV-160/161/162) and the Seal Water Return Containment Isolations (QCM-250/350) have closed.

B. Only the Letdown Containment Isolation Valves (QCR-300/301), Seal Water Return Containment Isolations (QCM-250/350) and Charging Header Isolation Valves (QMO-200/201) have closed.

C. Only the Letdown Containment Isolation Valves (QCR-300/301) and the Letdown Orifice Isolation Valves (QRV-160/161/162) have closed.

D. None of the CVCS System valves have closed, since the SI signal is what isolates ANSWER: A - Containment Phase A isolates the Letdown Containment Isolation Valves (QCR-300/301). Letdown Orifice Isolation Valves (QRV-I 60/161/162) and the Seal Water Return Containment Isolations (QCM-250/350).

B - Incorrect - The Charging header Isolation Valves are closed by the SI signal.

C - Incorrect - The Seal water return valves will also isolate.

D - Incorrect - Phase A will isolate the Letdown & Seal Return Paths.

the CVCS Containment paths.

REFERENCE:

SOD-00300-001 Charging and Letdown System LESSON PLAN/OBJ: RO-C-O1100/#6 KA - 103000 K4.06 Containment System Knowledge of Containment System design feature(s) and/or interlock(s) which provide for the following:

Containment isolation system RO/SRO Value - (3.1 / 3.7) CFR - 41.7 SOURCE: INPO # 27098 Millstone 3 - 7/16/2004 Original Quest. KA - 103.K4.06 2/20/2006 Page 94 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

66. 066 OOl/RO/OK/DIRECT-INPOIGINNA

. ~.

200428264/GENERIC 2.1.12/(2.9 /4.0)//H/3

~~~~~~

~~~~

A plant heatup was in progress, with the RCS at 300OF and 350 psig, when the South SI pump failed its surveillance and was declared inoperable. Which one of the below limits are placed on the plant heatup?

A. All ECCS LCOs satisfied, may operate in any mode.

BY ECCS LCO for this mode satisfied but may not proceed into mode 3.

C. ECCS LCO satisfied for this mode but enter a 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> clock when proceeding into mode 3.

D. ECCS LCO not satisfied, 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> to restore South SI pump, then 24 hrs to mode 5.

ANSWER: B - Mode 4 requires only 1 train of ECCS (with only RHR & CCP) p e r - E ~ ~

3.5.3. The SI pumps are not required to be operable until Mode 3 (>350OF). Entry into Mode 3 is not allowed since TS 3.0.4 prohibits changing modes if TS 3.5.2 is not met (2 full ECCS trains are required).

A - Incorrect since the LCO requirement for modes 1-3 are not met, C - Incorrect since the LCO for the current mode is met.

D - Incorrect since TS 3.0.4 prohibits changing mode 4 to 3.

REFERENCE:

Technical Specification 3.5.2, 3.5.3, 3.0.4

~__

LESSON PLAN/OBJ: RO-C-TSOl/#ll KA - Generic 2.1.12 Generic Conduct of Operations Ability to apply technical specifications for a system.

RO/SRO Value - (2.9 / 4.0) CFR - 43.2 / 43.5 / 45.3 SOURCE: INPO # 28264 Ginna 1 - 11/1/2004 Original Quest. KA - G2.1.12 2/20/2006 Page 95 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

67.

, Oh7 002/KO OK/I)IRI~CT-INPO,S,\\l.Ehl 200! - 211 IXGENERIC

?. I 191t3 (1s 3.(1),/1'/3 During steady state 100°/o power operation, you are performinga Plant Computer-Online Calorimetric Validation in accordance with Attachment 1 of 01 -0HP-4030-114-029 Reactor Thermal Power.

The computer points for Steam Generator (S/G) Blowdown are reading as follows:

14 PPC Value(apm) 98 100 95 96 SG #

11 12 13 I

PPC Color Green Magenta Green Green Local Value(gpm) 98 105 95 95 Which of the following is the correct response to these conditions?

A. Use the online calorimetric since the computer value for the #12 S/G is less than the actual blowdown.

B. Manually enter a value of 105 gpm for the #12 S/G Blowdown and insure the online calorimetric remains below 100%.

Cr Isolate the #12 SG Blowdown. The online calorimetric may be used after the plant has been stable for 10 minutes.

D. Use the online Calorimetric since the computer value for the #12 S/G is within allowed tolerance. The magenta color indicates a deviation from the other SGs.

ANSWER: C - The computer input for~#12 SG blowdown is inaccurate. The magenta reading means that it is inaccurate and should not be used. The SG #12 Blowown Flow should be Isolated. The online calorimetric may then be used.

A - Incorrect - The Computer value is inaccurate and should not be used if it is blue or magenta. Using a lower value is non conservative.

6 - Incorrect - The program does not have provisions for manually entering SG blowdown flows.

D - Incorrect - The Computer value is inaccurate and should not be used if it is blue or magenta.

~~~~

~

~~

~~~~

~

~

.~~~

~.

~~

~

~~

~~~~

~~~

-~

2/20/2006 Page 96 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

01-OHP-4030-114-029 Reactor Thermal Power LESSON PLAN/OBJ: RO-C-NOP07/#7.37 KA - Generic 2.1.I9 Generic Conduct of Operations Ability to use plant computer to obtain and evaluate parametric information on system or component status.

RO/SRO Value - (3.0 / 3.0) CFR - 45.12 SOURCE: INPO # 241 12 Salem Unit 1 - 5/5/2003 Original Quest. KA - 194001.G1.19 212012006 Page 97 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

-~

68.

~~~~~ 068 _ _ ~

002/RO/OK/DIRECT/COOK

~~~

~~~

~~~

2001 Q#56/GENERIC 2.1.2943.4

_ _ _ ~ ~

I3.3)/COOWF/2

~~~~~~

~

~

During an independent verification a valve is found out of position.

Which of the following is the way the component out of position shall be handled?

The component shall be repositioned...

A. by the person who did the initial lineup and then verified B. and verified by the person performing the verification C. and the supervisor notified of the discrepancy D!, after the supervisor gives the approval ANSWER: D - PMP-4043-ICV-001 requires notification of the supervisor for resolution of the discrepancy.

A - Incorrect - Procedure does not specify who realigns valve, but supervisor approval is required prior to repositioning.

B - Incorrect - Valve is repositioned and then independently verified after supervisor approval.

C - Incorrect - Valve is repositioned and then independently verified after supervisor approval.

~

~~~~~~

~~~~~~~

~. ~

~~~~~~

~~~~

~.

~~~~

~~~~~~~

~~

~

~

REFERENCE:

PMP-4043-ICV-001, Independent and Concurrent Verification Section 3.3.9 LESSON PLAN/OBJ: RO-C-ADM02/#5 KA - Generic 2.1.29 Generic Conduct of Operations Knowledge of how to conduct and verify valve lineups.

RO/SRO Value - (3.4 / 3.3) CFR - 41.IO / 45.1 / 45.12 SOURCE: INPO # 19510 Cook 1 - 5/21/2001 Original Quest. KA - 9.2.1.29 2/20/2006 Page 98 of 146

~

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

69. 069 (H)I/KO/O~II)IKt:CT,OI
\\l)hK'l ?-j/GENERIC 2.2.1 1/(2/

3.4~//F/2 When during the review/approval process does a On-The-Spot'Change (OTSC) become available for immediate use?

I A. Once the applicable 1 OCFR50.59 review is complete.

BY Following SRO review of the change and signature.

C. After the Qualified Technical Reviewer reviews the change.

D. When the Department Manager signs the change.

ANSWER: B - The procedure is ready for use after the SRO has approved the changes.

A - Incorrect - The 10CFR 50.59 review may be done after the procedure is used.

C - Incorrect - The SRO must review and approve the changes after the QTR.

D - Incorrect - The department manager does not need to sign.

REFERENCE:

PMP-2010-PRC-003 Procedure Use and Adherence Section 3.5.2

~

~~~

~

.______~.

LESSON PLAN/OBJ: RO-C-ADM12/#3.2 KA - Generic 2.2.1 1 Generic Equipment Control Knowledge of the process for controlling temporary changes.

RO/SRO Value - (2.5 / 3.4) CFR - 41.10 / 43.3 145.13 SOURCE: Master Bank 01ADMC12-3 Original Quest. KA - 2.2.6 (2.3/3.3)

EXAM/QUIZZES: R023ADM1 2/20/2006 Page 99 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test BY Loss of direct communications between control room and personnel at the refueling station.

C. Loss of the Fuel Handling Ventilation System.

D. Time since entering mode 3 is 155 hours0.00179 days <br />0.0431 hours <br />2.562831e-4 weeks <br />5.89775e-5 months <br />.

1

~~~~

~~

~

~

~~~

~~~

~-

~~

70. 070 002/RO/OK/DIRECT/R023-012-S

~~~~

(#I 2)/GENERIC 2.2.27/(2.6/3.S)//F/3 Unit 1 is in mode 6 and in the process of core offioad.

Which ONE (1) of the following limiting conditions requires immediate suspension of all COR E A LT E RAT1 0 NS?

212012006 Page 100 of 146

DC Cook 2006.NRC ILT Written Examination 2006 SRO Submitted Test

71. 071 002/RO/OWDIRECT/COOK 2001 RT Q#97/GENERIC 2.3.4K2.5 / 3.1)//F/3

~~

~~~~~~

.~

~~~

Prior to entering the Auxiliary Building for a tour, you identify a limited access area as-having the following readings:

Surface Contamination Level of 80 dpm/100 cm2 ct (Alpha)

General Area Radiation Level of 1200 rnRem/hr Airborne Radioactivity Level of 7 DAC-hours/week r

Which ONE of the following area postings should be displayed at the entrance to this area?

A. High Radiation and Contamination Area B. Very High Radiation and Airborne Area CY Locked High Radiation and Contamination Area D. Very High Radiation, Contamination and Airborne Area ANSW-ER: C~--

a Locked High Radiation area is defined as an Area accessible in~~which radiation levels could result in a dose equivalent in excess of 1000 mrem in 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at 30 cm. A Contamination area is defined as An area where loose surface contamination may exceed 1000 dpm/lOO cm2 smear or 20 dpm/100 cm2 of a.

A - Incorrect - The area is required to be posted as a LOCKED high rad area.

B - Incorrect - The area does not exceed the Very High limit of 500 rads in 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at 1 meter nor the Airborne level of 12 DAC-hourdweek.

D -Incorrect - The area does not exceed the Very High limit of 500 rads in 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> at 1 meter nor the Airborne level of 12 DAC-hourdweek.

i

~~~

~.

~~~~~~~~

~

~

~~

~~~

~

REFERENCE:

PMI-6010 Rev 15 section 4.7 LESSON PLAN/OBJ: RO-C-RP02/#7 KA - Generic 2.3.4 Generic Radiological Controls Knowledge of radiation exposure limits and contamination control, including permissible levels in excess of those authorized.

ROlSRO Value - (2.5 / 3.1) CFR - 43.4 / 45.10 SOURCE: INPO # 20261 Cook 1 - 9/10/2001 Original Quest. KA - 92.3.4 2/20/2006 Page 101 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test I

72. 072

~~~~ 02 I /RO/OKMEW//CENERIC_?12.9/(~.~.4)//F/Z

~

~

~~

Which ONE of the following describes the Operation of the Containment Purge System (in Ventilation Mode) while the Containment equipment Hatch is open?

r A. Air flow must be OUT of Containment to prevent to minimize radiation levels.

B:,

Air flow must be INTO Containment to prevent the spread of contamination.

C. Containment Purge Exhaust and Supply flows must be matched to ensure the I

Containment and Aux Building are maintained at the same pressure.

D. Containment Purge Exhaust and Supply flows must be balanced to prevent Ice Condenser doors from opening.

~~~~~

~.~~

___~

~~~~~~

~~~~

ANSWER: B - A lower pressure in containment with respect to the Aux Building will cause an airflow into containment and help to minimize the spread of contamination.

A - Incorrect - Air Flow is maintained into Containment.

C - Incorrect - Aux Building and Containment Pressures are not maintained equal.

D - Incorrect - This concern is addressed by the UppedLower Containment Pressure balance.

REFERENCE:

01 -0HP-4021-028-005, Operation Of The Containment Purge System,, step 3.7 and Figure 2 LESSON PLAN/OBJ: RO-C-02800 /#4 KA - Generic 2.3.9 Generic Radiological Controls Knowledge of the process for performing a containment purge.

RO/SRO Value - (2.5 / 3.4) CFR - 43.4 / 45.10 2/20/2006 Page 102 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

73. 073 OIOIRO/OK-REPEATlDIRECTKOOK

~

~

~

2004 QW6/GENERIC

-~

2.3.10/(2.9

~.

/ 3.3)//F/3

~~~~~

~

Unit 1 has experienced a Large Break LOCA. All safeguards equipment functioned properly following the event initiation. You are the BOP assigned to perform 01 -0HP-4023-E-0, Reactor Trip or Safety Injection Attachment A.

Which ONE of the following describes the action required for the Control Room Pressurization fans and why?

A. Manually start both pressurization fans to ensure that enough pressure exists to ensure adequate filter flow.

B. Verify that both pressurization fans automatically start to ensure that enough pressure exists to ensure adequate filter flow.

within analyzed limits.

CY Manually stop one pressurization fan to ensure that control room dose remains D. Notify Unit 2 control room to start both pressurization fans if one Unit 1 fan is NOT running to ensure that control room dose remains within analyzed limits.

~

~~

~

~~

~

~

~~~~~~~~~

~

~~~

~

~~~

~.

~~

~~~

~

~

~

ANSWER:C -

Attachment A Step 4 provides direction to stop 1 pressurization fan to limit the filter flow rates to ensure the dose remains within limits.

A - Incorrect - Both fans are expected to auto start and one fan must be stopped.

B - Incorrect - One fan must be stopped to limit the filter flow rate.

D - Incorrect - One pressurization fan for each Unit through its respectjve (hdependent) filter train is required.

2/20/2006 Page 103 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

01-OHP-4023-E-0, Reactor Trip or Safety Injection Attachment A pg. 35 PSBD 12-OHP-4023-E-0 background document pg. 75 LESSON PLAN/OBJ: RO-C-EOP03/#22 KA - Generic 2.3.1 0 Generic Radiological Controls Ability to perform procedures to reduce excessive levels of radiation and guard against personnel exposure.

RO/SRO Value - (2.9 / 3.3) CFR - 43.4 / 45.10 SOURCE: INPO # 27700 Cook 1 - 4/29/2004 (RO#OSS/SR0#066)

Original Quest. KA - 2.3.1 0 Generic Radiological Controls Ability to perform procedures to reduce excessive levels of radiation and guard against personnel exposure.

RO-2.9 SRO-3.3 2/20/2006 Page 104 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~-

74. ____

074 00l/RO/OWMODILlED/COOK

~ ~ _ _ _ _

~

2001

~~~~~~

RT.. Q#73/GENERIC 2.4.29/(2.6 /4.O)!COOK/F/2

~~

FOLLOWING the Initial Notifications for an Emergency Plan accident classified as an ALERT, the SEC must FAX an updated EMD-32 form to the State of Michigan every

~

minutes until relieved by the EOF.

A. 15 C. 60 D. 120 ANSWER: B - PMP-2080-EPP-100 Attachment 8 Section 3.1 requires EMD32 followup notifications every 30 minutes.

A - Incorrect - 15 minutes is required for initial notifications.

C - Incorrect - 60 Minutes is the notification time for the NRC D - Incorrect - Followup notifications are required every 30 minutes.

~~

~~

~~~~~~~~

~ J

~

..~___.

Changed stem to Following initial notification and to Michigan vs sheriff. Changed Distracters from 5,10,15,20 minutes. Answer Changed to 30 Minutes from 15 minutes.

REFERENCE:

PMP-2080-EPP-100 Attachment 8 Section 3.1 LESSON PLAN/OBJ: ST-C-EP04/#5 KA - Generic 2.4.29 Generic Emergency Procedures/Plan Knowledge of the emergency plan.

RO/SRO Value - (2.6 / 4.0) CFR - 43.5 / 45.1 1 SOURCE: INPO # 20238 Cook 1 - 9/10/2001 from 12EPPC0303 2 Original Quest. KA - g2.4.29 2/20/2006 Page 105 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~

75.

.~ 075 OOI/RO/OK/DIRECT/COOK 2001 Q#IO/GENERIC

~~~~

2.4.50/(3,3. /3.3)/COOWH/3

~

The plant is in Mode 4 on RHR. NPS-121, Wide Range RCS pressure instrument is de-energized for maintenance. During a control board walkdown you discovered that Panel 206 Drop 36, RHR OPEN TO HI RCS HOT LEG PRESSURE, was illuminated.

What would cause this condition?

A. RHR valve 2-ICM-129 (RHR pump suction from Loop 2 hot leg) is open, reactor coolant system pressure is 491.25 psig and rising.

B. RHR valve 2-ICM-129 (RHR pump suction from Loop 2 hot leg) is closed, reactor coolant system pressure is 491.25 psig and lowering.

CY RHR valve 2-IMO-128 (RHR pump suction from Loop 2 hot leg) is open, reactor D. RHR valve 2-IMO-128 (RHR pump suction from Loop 2 hot leg) is closed, ANSWER: C - Panel 206 Drop36 will alarm with either NPS-121 at~>491.25 psig and ICM-129 open or with NPS-122 at >491.25 psig and IMO-128 open. Since NPS-121 is deenergized the alarm is from IMO-128 and rising pressure.

A - Incorrect - ICM-129 is alarmed from NPS-121 which is De-energized per the stem.

B - Incorrect - ICM-129 not FULLY closed and rising pressure causes the alarm from NPS-121 which is De-energized per the stem.

D - Incorrect - IMO-128 not FULLY closed and rising pressure causes the alarm.

coolant system pressure is 491.25 psig and rising.

reactor coolant system pressure is 491.25 psig and lowering.

~~~~~

~~~

~~~~~~~

~~

~~

~~~~~

~~~~~~

~~~

~

REFERENCE:

02-OHP 4024.206 Drop 36, SOD-01 700-002 LESSON PLAN/OBJ: RO-C-O1700/#7 KA - Generic 2.4.50 Generic Emergency Procedures/Plan Ability to verify system alarm setpoints and operate controls identified in the alarm response manual.

RO/SRO Value - (3.3 / 3.3) CFR - 45.3 SOURCE: INPO # 19318 Cook 1 - 5/21/2001 Original Quest. KA - 000025.g2.4 2/20/2006 Page 106 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

76. 076 01 I/SRO/OK/hlOl)ll;lED/COOK ?MU SROK071/OOU009 2 2 2Y12.5 / 3 7)/.1+!

Technical Specificaiion LCO 3.5.5 Seal.lyection Flow places limits on RCP seal injection flow resistance.

Which ONE of the following describes the reason for maintaining RCP seal injection flow resistance?

A. If the resistance is too small, Auxiliary Spray flow may be less than required for RCS depressurization during a Steam Generator Tube Rupture.

B. If the resistance is too large, RCP seals may overheat during a large break LOCA.

C. If the resistance is too large, Charging Pump minimum flow may be less than required for pump cooling during a small break LOCA.

core cooling during a small break LOCA.

D!' If the resistance is too small, ECCS injection flow may be less than required for

~~~~~~

~

~

~~~

A N s w E R : ~ D - ~ ~

~~~~~

~

~

~

~

~~~~

~

~

~~~~~

~

~~.~~

The limitation on seal line resistance is to ensure that the minimum safeguards flow to the RCS will be sufficient for core cooling. The analysis assumes that flow diverted from the BIT line to seal injection is lost to core cooling.

A - Incorrect - Auxiliary Spray flow varies depending on plant conditions. it is not required to be any specific value during accident conditions.

B - Incorrect - In the event of a Large Break LOCA the CCP will inject less flow to the RCP seals but the limit requires a minimum seal resistance not maximum.

C - Incorrect - Charging flow minimum flow will come off prior to seal injection. (Pump is only concerned with total flow for cooling)

REFERENCE:

Technical Specification 3.5.5 and Bases LESSON PLAN/OBJ: RO-C-00200/#14 KA - 000009 2.2.25 Small Break LOCA Equipment Control Knowledge of bases in technical specifications for limiting conditions for operations and safety limits.

RO/SRO Value - (2.5 / 3.7) CFR - 43.2 2/20/2006 Page 107 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

77. 077 003ISROIOWDIRECT-INPO/KEWAUNEE 2000- 19406/000~1~~6/(2.!/4.3)//Hm~~.

~~

The following conditions exist:

- A LOCA has occurred from HOT SHUTDOWN conditions 30 minutes ago

- RCS pressure is 125 psig

- RCS Core Exit TCs read 380OF

- RCS Cold Leg temperatures are both 250OF

- 1 N SI Pump is running providing 325 gpm flow

- 1 E RHR Pump is running providing 1150 gpm flow What is the appropriate action taken in response to the above conditions?

Entry into 01 -0HP-4023-FR-P.l Response to Pressurized Thermal Shock Condition is A!' made but NO actions are implemented before returning to procedure in effect.

B. made and cooldown will continue within a limit of 50OF in any 60 minute period.

C. made and a RCS temperature soak for a ONE hour period will be completed.

D. NOT required since RCS pressure is below 300 psig.

ANSwERi~~A

~-u~Entryinto-FRTIi isreq;irede~-tcthe orange Path with-RCS-at

~285OF. The first step of P.l checks RCS pressure at greater than 300 psig. Since Pressure is less than 300 psig and RHR flow is >400gpm, no actions are performed and the operator is directed back to the procedure & step in effect.

B - Incorrect - Cooldown is not limited since the RCS has already experienced a large break.

C - Incorrect - A soak is not required since the RCS has already experienced a large break.

D - Incorrect - Entry into the procedure is still required and a pressure and flow check is made within the procedure.

2/20/2006 Page 108 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

01 -0HP-4023-FR-P.l LESSON PLAN/OBJ: RO-C-EOP12/#25 KA - 00001 1 2.1.6 Large Break LOCA Conduct of Operations Ability to supervise and assume a management role during plant transients and upset conditions.

RO/SRO Value - (2.1 14.3) CFR - 43.5 145.12 145.13 SOURCE: INPO # 19406 Kewaunee, Unit 1 - 12/11/2000 Original Quest. KA - 011.EK3.10 2/20/2006 Page 109 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

78. 078 003/SRO/OK/DIRECT/OIEOPCO922-I 1/OOOO1 I 2.3.10/(2.9 / 3.3)//H/3

~~~

~

~~~~~~

~-

~~~

~~~

. ~ _ ~ _ _ _

~.

The unit has suffered a large break LOCA. The operators are currently performing OHP-4023-ES-1.3, Transfer to Cold Leg Recirculation, step 12, realigning SI pump Recirculation valves IMO-262 and IMO-263. While attempting to close IMO-263, SI Pump Recirc to RWST, the MCC breaker trips open on overload and will not reset.

The crew should...

A. not continue with the procedure until the AEO has locally closed IMO-263, SI Pump Recirc to RWST, to prevent contaminating the RWST.

B. not continue with the procedure until the AEO has locally closed IMO-263, SI Pump Recirc to RWST, since it is an interlock to open IMO-340, CCP Suction from East RHR Hx, and IMO-350, SI Pump Suction from West RHR Hx.

CY verify IMO-262, SI Pump Recirc to RWST, is closed and continue with the procedure since adequate isolation exists and required interlocks are met.

Recirc to RWST, is resolved.

D. leave the SI pumps aligned to the RWST until the operability of IMO-263, SI Pump

~~~~~

~~~

. ~~~~~~~~

~

~

~~~

I

~~~~~~~

~~~~~~~

ANSWER: C - OHP-4023-ES-1.3, Transfer to~~Cold~

Leg Recirculation, step 12, requires that 1 of the SI recirc valves be closed. The valves are in series to isolate flow back to the RWST. Closing at least one valve satisfies the interlock and prevents the return of radioactive water to the RWST.

A - Incorrect - Only 1 valve is required to be isolated.

B - Incorrect - Only 1 valve is required to be isolated.

D - Incorrect - Only 1 valve is required to be isolated. The SI pumps can not be left alinnnri tn the RWST since its level is lowerinn LESSON PLANiOBJ: RO-C-EOP09/#36 KA - 00001 1 2.3.10 Large Break LOCA Radiological Controls Ahilitv tn nnrfnrm nrncedures tn reduce excessive levels of radiation and auard aaainst

~.

personnel exposure.

RO/SRO Value - (2.9 / 3.3) CFR - 43.4 / 45.10 SOURCE: Bank 01 EOPC0922-11 Original Quest. KA - 00001 1 EAl.13 (4.1/4.2)

EXAM/QUIZZES:

R022EOP5A; R022EOP5B R020ECOMP; R021 EOP5; RQ2604A; RQ2604C; RQ2604E; 2/20/2006 Page 110 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

79. 079 006/SROlOK/NEW/lO00033 2.4.46/(3.5 l3.6)lH/3

~~

~

Unit 2 is performing a shutdown.

The following conditions exist :

- Reactor is critical at 8% power.

- Annunciator Panel 110 Drop 8, INTMED RANGE COMPENSATE VOLT FAILURE alarms.

How does this affect the Nuclear Instrumentation?

A. N36 reading would immediately rise about 1 decade. The channel will be B. N36 reading would immediately drop about 1 decade. The channel will be C. N36 reading would NOT immediately change. The channel will be OPERABLE for Dr N36 reading would NOT immediately change. The channel will be INOPERABLE ANSWER: D - When the compensating voltage is lost, while in the power range the effect will not be noticed since the impact from the gamma radiation is a small percentage of the total current. At lower power levels, excessive gamma current will cause the IR detector to indicate excessively HIGH. This may result in 1 of 2 channels remaining above the P-6 setpoint, which would keep all P-6 blocking features active.

A - Incorrect - While in the power range the impact from gamma and the gamma compensation is a small percentage of the actual current. The channel will indicate high as power is reduced and so will not actuate P-6 at the correct time.

B - Incorrect - While in the power range the impact from gamma and the gamma compensation is a small percentage of the actual current. The channel will indicate high as power is reduced and so will not actuate P-6 at the correct time.

C - Incorrect - Both IR channels must be below P-6 to energize the SR. So the P-6 Function of the IR channel would be Inoperable.

INOPERABLE for the P-6 Function once power is reduced.

OPERABLE for the P-6 Function once power is reduced.

the P-6 Function once power is reduced.

for the P-6 Function once power is reduced.

~

~

~~~~~

~

2/20/2006 Page 11 1 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

RO-C-01300 Excore Nuclear Instrumentation System Handout #3, TS 3.3.1 and Bases.

LESSON PLANIOBJ: RO-C-O13001#9 KA - 000033 2.4.46 Loss of Intermediate Range Nuclear Instrumentation Emergency ProcedureslPlan Ability to verify that the alarms are consistent with the plant conditions ROISRO Value - (3.5 13.6) CFR - 43.5 145.3 145.12 212012006 Page112of146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~~-

80. 080 020/SRO/OK/MODIFIED/COOK

~~~~~~

2004 #73/000040 AAZ.OlK4.2 /4.7)/R1/4 The following alarms are received on Unit 2:

Steam Gen 1/2/3/4 Steam Line Flow High Alarms Steam Gen 1/2/3/4 SF>FWF Flow Mismatch Alarms The following conditions exist:

- RCS Tavg is 561 OF and lowering

- Turbine load is lowering

- Rods are stepping out

- Steam flows are - 3.6 x 106 Ibm/hr

- FW flows are - 2.1 x 106 Ibm/hr Which one of the following correctly describes the cause and required action to be taken for the above conditions?

A? A steam line break exists. Direct the operators to perform a Reactor Trip and Main B. A feed line break exists. Direct the operators to perform a Reactor Trip and Main Steamline Isolation.

Feedwater Isolation.

C. Feedwater Pump delta P is too Low. Direct the operator to raise FW Pump Speed and FW pump flow.

D. MPC-253 has failed LOW. Direct the operators to perform actions for failed First Stage Turbine Impulse Pressure Transmitter.

~

~

~~~~~~~

~

~

~~~~~

~~~~

~~~~~

~~~

~

~~~

~~

ANSWER:A -

Based on the conditions presented a steam line break has occurred. Steam flow is indicating at the 97 to 98% power range. Tavg is 13OF Low for 98% power. A reactor trip and Steam Line isolation is warranted.

B - Incorrect - If A FW break existed RCS temperature would be rising.

C - Incorrect - If FW Flow was low RCS Temperature would be rising.

D - Incorrect - If MPC-253 failed low the alarms would come in (Steam flow higher than calculated power) but rods would step out and SF/FWF mismatch would not be this high.

2/20/2006 Page113of146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test Changed stem Steam Flow. Added FW flow to Stem. added SF>FWF Alarm.

Changed distractors B & C to include FW flow. Changed all distractors to include Operator actions.

REFERENCE:

RO-C-05103 Main Steam Systems pg. 9 SD-01 100 RPS/ESFAS Signals System Description pg. 56 LESSON PLAN/OBJ: RO-C-05103/#9 KA - 000040 AA2.01 Steam Line Rupture Ability to determine and interpret the following as they apply to the Steam Line Rupture:

Occurrence and location of a steam line rupture from pressure and flow indications RO/SRO Value - (4.2 / 4.7) CFR - 43.5 / 45.1 3 SOURCE: INPO # 27707 Cook 1 - 4/29/2004(RO#O73/SRO#NA)

Original Quest. KA - 000040 AA2.02 Steam Line Rupture Ability to determine and interpret the following as they apply to the Steam Line Rupture:

Conditions requiring a reactor trip RO-4.6 SRO-4.7 2/20/2006 Page114of146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~~ 81

~. 081

~~~~~

002/SRO/OWNEW//000057

.~~

~~~~~~

AA2.08/(3.4 /3.5)//w3

~

~

~

~.

~

The following plant conditions exist on Unit 2:

The Plant is in Mode 3 preparing for Reactor Startup.

Gamma Metrics Detector N23 is Inoperable.

A Loss of CRlD I has occurred and operators have taken actions to stabilize the plant.

What one of the following actions are required for the Neutron Flux Function of Technical Specification 3.3.3, Post Accident Monitoring Instrumentation based on these events? (Technical Specification 3.3.3, Post Accident Monitoring Instrumentation attached)

A. Restore Either Neutron Flux Detector to Operable status immediately or be in Mode 4 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

BY Restore Either Neutron Flux Detector to Operable status within 7 Days from the Loss of N21.

C. Restore Neutron Flux Detector N23 to Operable status within 30 Days from the Loss of N23. N21 was not impacted by the loss of CRlD 1 since it is powered from Unit 1.

D. Restore Both Neutron Flux Detectors to Operable status within 30 Days from the ANSWER: 6 - CRlD I supplies power to N21. TS 3.3.3 requires 2 channels operable for the Neutron Flux Function. Loss of one channel allows 30 Days for repair. A loss of 2 Channels requires that 1 be restored within 7 Days.

A - Incorrect - This is the Action required by Condition G which is referenced in the Table if the other actions are not completed within the allowable time.

C - Incorrect - The N23 channels on both Units are powered from the Opposite Unit.

The N21 Channels are powered from the respective unit.

D - Incorrect - This is the Action required for ONE Channel. Plausible if the candidate confused function with channel (Action A).

Loss of N23.

~~

~

~~~~~~

~~~~

~~~~~

~~~~~~~

.. ~~~~~~

~~~

~

2/20/2006 Page 115 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

Technical Specification 3.3.3 Post Accident Monitoring Instrumentation LESSON PLAN/OBJ: RO-C-O1300/#21 Attachment Provided - Technical Specification 3.3.3 Post Accident Monitoring Instrumentation pg. 3.3.3-1 to 3.3.3-5 KA - 000057 AA2.08 Loss of Vital AC Electrical Instrument Bus Ability to determine and interpret the following as they apply to the Loss of Vital AC Instrument Bus:

Reactor power digital display and remote flux meter RO/SRO Value - (3.4 / 3.5) CFR - 43.5 / 45.13 2/20/2006 Page116of146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

82.

~ 082

~~~~

001/SRO/OWDIRECT-INPO/TURKEY

~~~~~~

PT 2003-26557/000065 AA2.06~~3.6~/4~1)/~/3

~~~~

~

~ ~~-~

02-OHP-4022-064-001, Control Air--Malfunction, directs the operator to Check 100 PSlG Control Air Header Pressure on XPI-100.

Which ONE of the following should the SRO direct with respect to 02-OHP-4022-064-001, if air pressure cannot be maintained?

A. If the plant is experiencing symptoms of a loss of Control Air AND system pressure reaches 95 psig then close the Plant Air Header Unit Crosstie valves. If pressure is still lowering then trip the reactor and go to 02-OHP-4023-E-0, Reactor Trip or Safety Injection.

BY If the plant is experiencing symptoms of a loss of Control Air AND system pressure reaches 80 psig and is still lowering, trip the reactor and go to 02-OHP-4023-E-0, Reactor Trip or Safety Injection.

reaches 90 psig and is still lowering, then close the Plant Air Header Unit Crosstie valves and start both Control Air compressors.

C. If the plant is experiencing symptoms of a loss of Control Air AND system pressure D. If the plant is experiencing symptoms of a loss of Control Air AND system pressure reaches 80 psig and is still lowering, then close the Containment Air Header Isolation valves and start a unit shutdown.

ANSWER: B OHP-4022-064-001, Control Air Malfunction directs a reactor trip if Control Air Pressure is <80 psig.

A - Incorrect - The plant is not tripped until pressure is <80 psig. The PAC will auto start at 95 psig.

C - Incorrect - The crossties are closed at <85 psig. The Control Air compressors will start at 90 psig.

D - Incorrect - The plant should be tripped when pressure reaches <80 psig.

Containment is isolated if it appears to be the source of the leak.

~

~~~~~~~~~~~~~

~~

~

~...

~

~

~~

~~~~~~

~

~~~~~~~

2/20/2006 Page117of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

02-OHP-4022-064-001, Control Air Malfunction Step 1 LESSON PLAN/OBJ: RO-C-06401/#8 KA - 000065 AA2.06 Loss of Instrument Air Ability to determine and interpret the following as they apply to the Loss of Instrument Air:

When to trip reactor if instrument air pressure is decreasing RO/SRO Value - (3.6 / 4.2) CFR - 43.5 I45.13 SOURCE: INPO # 26557 Turkey Point 3 - 12/15/2003 Original Quest. KA - 065AG2.1.6 2/20/2006 Page118of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~

83. 083

~~~

003/SRO/OWDIRECT/ITS

  1. 89/006000 2.2.24K2.6 / 3.8)//H/3 The plant is at 95% power.

- 1200 on April 3, the 1 S SI pump is declared inoperable.

- 1430 on April 4, the 1 W Centrifugal Charging pump is declared inoperable.

- 1430 on April 5, the 1 S SI pump is restored to OPERABLE status.

Including any extensions that are permitted by TS, which one of the following describes I the LATEST time and date to restore the 1 W Centrifugal Charging pump to OPERABLE status without requiring a unit shutdown?

A:,

1200 on April 6 B. 1200 on April 7 C. 1430 on April 7 D. 1430 on April 8 ANSWER: A - Since the S SI pump and W Centrifugal Charging pump are associated~

with the same ECCS train, the inoperability of the W Centrifugal Charging pump does NOT constitute a subsequent failure expressed in the Condition. Condition A specifies one ECCS train. The subsequent inoperability above is in the same train. Therefore, a Completion Time extension is NOT allowed.

6 - Incorrect - The LCO is for the ECCS train with a total of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> from the first failure.

C - Incorrect - The LCO is for the ECCS train with a total of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> from the first failure.

D - Incorrect - The LCO is for the ECCS train with a total of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> from the first failure.

1

~~

~~~~~

~~~~~

~~

~~

~~

~.~~

~

- -~

~

~~~~

~

~~

REFERENCE:

TS 3.5.2, Condition A LESSON PLAN/OBJ: RO-C-TSOl/#ll KA - 006000 2.2.24 Emergency Core Cooling System (ECCS)

Equipment Control Ability to analyze the affect of maintenance activities on LCO status.

RO/SRO Value - (2.6

/ 3.8) CFR - 43.2 / 45.1 3 SOURCE: ITS Exam Question #89 2/20/2006 Page119of146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~ 84. 084

~~~

01 I/SRO/OWMODIFIED/R023-074-3

(#068)/008000 A2.04K3.3 /3.5)//H/3

~~~~

.~

The following plant conditions exist on Unit 2:

- The East CCW HX is in service with the West CCW Pump running.

- CCW Surge Tank level is stable.

- CRS-4301, East CCW HX Radiation Monitor, generates an External Failure Alarm due to a faulty flow switch Which ONE of the following describes the response of the CCW system and the required actions, if any, for this condition?

A. No automatic actions will occur since the West CCW pump is running. No Lineup changes are required, operation in this condition is allowed indefinitely. The CCW system remains operable.

6. No automatic actions will occur since the CRS-4401, West CCW HX Radiation Monitor is still functioning. The West CCW HX must be aligned so the 2-CRV-412 Vent Valve will automatically close on a high radiation signal. The East CCW HX must be declared Inoperable.

C. 2-CRV-412, CCW Surge Tank Vent Valve, will automatically close. The West CCW HX must be aligned so the 2-CRV-412 Vent Valve may be reopened. The East CCW HX must be declared Inoperable.

DJ 2-CRV-412, CCW Surge Tank Vent Valve, will automatically close. No Lineup changes are required, operation in this condition is allowed indefinitely. The CCW system remains operable.

ANSWER: Dpr~2--CKV-412, CC-W S i c i T k '. V < i f Sh"ioff~Valve~closeson~

High Rad Level Alarm, Low Sample Flow, External Failure on CRS-4300/4400, Channel 4301 -

East and/or Channel 4401-West. The automatic action is the closure of the Vent valve.

The closure of the vent and monitor failure don't impact system operability, so operation may continue with this lineup.

A - Incorrect - Plausible since the East CCW HX monitor may be associated with the East pump but either radiation monitor will cause the surge tank vent to isolate.

B - Incorrect - Plausible since the east monitor has failed and the west is still operational but an alarm or failure of either will cause the Surge tank vent to isolate.

C - Incorrect - Plausible since the Surge tank vent is isolated. Alignment to the West HX will not allow the vent to be reopened.

2/20/2006 Page 120 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test Changed stem to ask required actions. Included actions & operability in distracters and changed distractor C to include Automatic vent closure.

REFERENCE:

12-OHP-4024-139 #26 LESSON PLAN/OBJ:RO-C-O1350/#4 KA - 008000 A2.04 Component Cooling Water System (CCWS)

Ability to (a) predict the impacts of the following malfunctions or operations on the CCWS and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations:

PRMS alarm ROISRO Value - (3.3 13.5) CFR - 41.5 143.5 145.3 145.1 3 SOURCE: Audit R023-074-3 (#068)

Original Quest. KA - SYS 073 Al.01 (3.213.5)

Process or Effluent High Radiation

-Ability to predict and/or monitor changes in parameters associated with operating the PRM system controls including radiation levels.

CRS-4300/4400 Channel 4301 - East Channel 4401-West Rad Monitor Flow Switch has high and low setpoints which cause an external failure when reached. 2-CRV-412, CCW Surge Tank Vent Shutoff Valve closes on High Rad Level Alarm, Low Sample Flow, External Failure.

212012006 Page 121 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~~ 85.

~

085 OIO/SROIOK/MODIFIEDICOOK

~-

-~

2004 #80/00WE07 EA2.1/(3.2 / 4.0)//HI3 The control room operators are conducting a cooldown following a LOCA.

The following plant conditions exist:

- Core Exit TC's are 410°F.

- RCS Pressure is 260 psig.

- RVLlS Narrow Range is 36%.

- RVLIS Wide Range is 17%.

- RCP #23 is the only RCP Operating.

Which ONE of the following describes current core conditions @ operational requirements?(02-OHP-4023-F-0.2, Core Cooling status tree attached)

A. Saturated. The operators are required to immediately enter 02-OHP-4023-FR-C.3, Response to Saturated Core Cooling to restore subcooled core cooling.

E!, Saturated. At their discretion, the operators may perform 02-OHP-4023-FR-C.3, Response to Saturated Core Cooling to restore subcooled core cooling.

C. Degraded. The operators are required to immediately enter 02-OHP-4023-FR-C.2, Response to Degraded Core Cooling to prevent conditions from degrading to an inadequate core cooling condition.

D. Degraded. Prompt action must be taken to trip the RCP and enter 02-OHP-4023-FR-C.2, Response to Degraded Core Cooling or conditions could degrade to an inadequate core cooling condition.

ANSWER: B - 260 psig = 274.7 psia = 409°F-Edicating that SubGoli@~is <36OF. With 1 RCP running and WR RVLIS > 15% the correct procedure would be 02-OHP-4023-FR-C.3, Response to Saturated Core Cooling. This is a yellow path procedure so discretion is allowed.

A - Incorrect - This is a yellow path procedure so discretion is allowed.

C - Incorrect - Temperature is low enough and there is enough inventory that a degraded condition does not exist.

D - Incorrect - Temperature is low enough and there is enough inventory that a degraded condition does not exist. If the RCP were tripped with these conditions FR-C.2 may be required.

~~

~~

~~~

~~~~~

~

~~~

~~

~

~

~~~~~

~~~~

~~

2/20/2006 Page 122 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test Changed stem to include operating RCP. Changed RVLlS and temperatures. Changed distractors A & D from Subcooled & Inadequate to balance distracters.

REFERENCE:

02-OHP-4023-F-0.2, Critical Safety Functions Status Trees, Core Cooling Attachment Provided OHP-4023-F-0.2, Core Cooling status tree LESSON PLAN/OBJ: RO-C-EOP10/#21 KA - 00WE07 EA2.1 Saturated Core Cooling Ability to determine and interpret the following as they apply to the Saturated Core Cooling:

Facility conditions and selection of appropriate procedures during abnormal and emergency operations RO/SRO Value - (3.2 / 4.0) CFR - 43.5 / 45.13 SOURCE: INPO # 27714 Cook 1 - 4/29/2004 (RO#080/SRO# N/A)

Modified from Bank 12EOPC1003-1 Original Quest. KA - 00WE07 EA2.1 Saturated Core Cooling Ability to determine and interpret the following as they apply to the Saturated Core Cooling:

Facility conditions and selection of appropriate procedures during abnormal and emergency operations RO-3.2 SRO-4.0 2/20/2006 Page 123 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

86. 086 ~.

~

004ISROIOWDIRECTIAUDIT R022 Q#25/00WEI I EA2.2N3.4 /4.2)/fHl3 Unit 1 is responding to a LOCA.

Upon entering 01 -0HP-4023-ECA-1.1, Loss of Emergency Coolant Recirculation, the following conditions existed:

- 1 W RHR pump - tagged out

- 1 E RHR stopped when 1-ICM-305, Recirc Sump to East RHR/CTS Pumps, could NOT be opened

- Containment pressure - 11 psig

- RCS pressure - 1200 psig

- RWST level - 16%

- Both SI pumps are shutdown, but available

- Both CCPs are running

- Both CTS Pumps are running

- No RCPs are running The crew has reached step 12, Check if an RCP should be started.

Which ONE of the following list the pump(s) that should be running at this point in the procedure? (01 -0HP-4023-ECA 1-1, Steps 1-1 2 are attached.)

A AnCCPonly B. An CCP and an CTS pump only.

C!, An CCP, an SI pump and one CTS pump only.

D. An CCP, an SI pump and both CTS pumps.

ANSWER. C - One CTS pump is stopped at step 5 when according tothe table:one CTS pump IS required. One CCP is stopped in step 1 la. One SI pump is started at step 11 b.

A - Incorrect - Candidate believes both CTS pumps are stopped and misses the SI pump start.

E3 - Incorrect - Candidate misses SI pump start.

D - Incorrect - Candidate misses step to stop CTS pump.

~

~~

~-

~ __

Page 124 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

01 -0HP-4023-ECA-1-1 LESSON PLAN/OBJ: RO-C-EOP09/#45 Attachment Provided 0HP-4023-ECA 1-1, Steps 1-1 2.

Loss of Emergency Coolant Recirculation Ability to determine and interpret the following as they apply to the Loss of Emergency Coolant Recirculation:

Adherence to appropriate procedures and operation within the limitations in the facility's license and amendments RO/SRO Value - (3.4 I4.2) CFR - 43.5 / 45.13 KA - 00WE11 EA2.2 SOURCE: AUDIT R022 Q#25 Original Quest. KA - WE 11 G2.1.7 2/20/2006 Page 125 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

87. 087 004/SRO/OWMODIFIED/COOK 2004 #82/00WE13 2.1.7/(7.7j 4.4)/R1/3-

~

~~~~~~~

~~

nit 1 reactor has been manually tripped due to a secondary system malfunction.

01 -0HP-4023-E-0 has been performed and a transition made to 01 -0HP-4023-ES-0.1 Reactor Trip Response. The STA has identified a YELLOW path on the Heat Sink Status Tree for steam generator pressure.

The crew has entered 01 -0HP-4023-FR-H.2, Response to Steam Generator Overpressure.

The following conditions exist:

- Steam Generator #13 Pressure - 1 100 psig

- Steam Generator #I3 NR Level - 93%

What is the appropriate action relative to steam release from SIG #13?

A. Steam release should NOT occur because it may result in excessive RCS cooldowr and depressurization, potentially causing a SI.

B? Steam release should NOT occur because it may result in two phase flow and water hammer, potentially damaging pipes and valves.

C. Steam may be released via the SG PORV ONLY since narrow range level is greater than 67%.

D. Steam may be released without restriction since narrow range level has been adequately established.

~~

~~

~~

~~~

~~~

~~~~

~

~~

ANSWEKB -

Per 01-OHP-4023-FR-H.2 Step 3, if the SG level is >92% a transition is made to 01-OHP-4023-FR-H.3 to address the high level that may be causing the pressure concern. Also as discussed in 01-OHP-4023-FR-H.3 Step 1, with a high SG level steam should not be released until the steam lines can be evaluated.

A - Incorrect - The higher level in the SG should have little effect on the RCS pressure drop. An SI would not be expected from a single SG steam release.

C - Incorrect - Steam release through the SG PORV could still lead to water hammer.

D - Incorrect - At this high of level Steam should not be released.

2/20/2006 Page 126 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test Modified stem to remove statement that a transition to H.3 is required and changed question to ask correct action vs. reason for transition.

changed distractors to include Steam Release or NOT and changed reasons for A, C,

& D.

REFERENCE:

01 -0HP-4023-FR-H.2, Response to Steam Generator Overpressure pg.

2 01-OHP-4023-FR-H.3, Response to Steam Generator High Level pg. 2 PSBD 12-OHP-4023-FR-H.2 Background Document pg. 7 PSBD 12-OHP-4023-FR-H.3 Background Document pg. 5-6 LESSON PLAN/OBJ:RO-C-EOPI 1/#10 KA - OOW E l 3 2.1.7 Steam Generator Overpressure Conduct of Operations Ability to evaluate plant performance and make operational judgments based on operating characteristics, reactor behavior, and instrument interpretation.

RO/SRO Value - (3.7 / 4.4) CFR - 43.5 / 45.12 / 45.13 SOURCE: Cook 2004 Question #82 From INPO 21508-BRAIDWOODO2 Original Quest. KA - 00WE13 EK3.4 Steam Generator Overpressure Knowledge of the reasons for the following responses as they apply to the Steam Generator Overpressure:

RO or SRO function within the control room team as appropriate to the assigned position, in such a way that procedures are adhered to and the limitations in the facilities license and amendments are not violated RO-3.1 SRO-3.3 2/20/2006 Page 127 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

88. 088 003/SRO/OWDIRECT-1NPO~R~R~S-2004-27561/00~E~5~EA2.2/(2.9

/ 3.3)//H/3_-

~~

The following conditions exist :

-Large Break LOCA is in progress

-Containment pressure is 1.9 psig and stable

-You notice an ORANGE condition on CONTAINMENT CSF ST due to the "FLOOD LEVEL" lights being Lit.

What action will be directed by OHP-4023-FR-FR 2.2, Response to Containment Flooding, and what is the concern if these actions are not successful?

A. Divert RHR flow from the Containment Sump to the RWST to lower Containment Level. High water levels could result in critical components needed for plant recovery being damaged and rendered inoperable.

B. Identify and isolate the source of excess water using control board indications and Containment Sump samples. Water levels could reach the bottom of the reactor vessel resulting in thermal shock and vessel failure.

CY Identify and isolate the source of excess water using control board indications and Containment Sump samples. High water levels could result in critical components needed for plant recovery being damaged and rendered inoperable.

D. Stop both containment spray pumps. Water levels could reach the bottom of the ANSWER: C~-r~Containment design basis flood level takes into account the entire water contents of the RCS, RWST, Ice condenser ice bed melt, and SI accumulators, plus the added mass of a LOCA and a steam line or feedline break inside containment.

NESW and CCW may be major contributors to exceeding "flood" level and causing a loss of equipment required for long term cooling.

A - Incorrect - Water is not pumped out of containment using the RHR pumps.

B - Incorrect - Water reaching the Reactor vessel would not cause thermal shock or vessel failure.

D - Incorrect - The CTS pumps are not stopped due to high level. Water reaching the Reactor vessel would not cause thermal shock or vessel failure.

reactor vessel resulting in thermal shock and vessel failure.

__-~

~~

~~

2/20/2006 Page 128 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

12-OHP-4023-FA-Z-2, Response to Containment Flooding Background; RO-C-EOPl3, Containment CSFST, FR-Z Series EOPs and Background Information LESSON PLAN/OBJ: RO-C-EOPl3/#6 KA - 00WE15 EA2.2 Containment Flooding Ability to determine and interpret the following as they apply to the Containment Flooding:

Adherence to appropriate procedures and operation within the limitations in the facility's license and amendments RO/SRO Value - (2.9 / 3.3) CFR - 43.5 / 45.13 SOURCE: INPO # 27561 Prairie Island - 4/23/2004 Original Quest. KA - E l 5 EKl.3 2/20/2006 Page 129 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

89. 089 002/SRO/OWDIRECT/AUDIT

~~~~

R023 Q#86/00WE16 EA2.2K3.0 /3.3)//w3

~~-

~~~~~

~.

Chemistry had just confirmed two leaking fuel rodson Unit 1 when a LOCA occured The following conditions exist: OHP-4023-E-0 Reactor Trip or Safety Injection is complete 0HP-4023-ES-1.3 Transfer to Cold Leg Recirc is complete OHP-4023-E-1 Loss of Reactor or Secondary Coolant is complete 0HP-4023-ES-1.2 Post LOCA Cooldown and Depressurization is in effect.

- All Red and Orange Paths have been addressed

- Lower Containment high range area monitors, (VRA-1310/1410) are reading 1 OR/HR

- Pressurizer level is 0%

The SM directs you to implement the highest priority Yellow Path procedure.

Which ONE of the following describes the proper procedural implementation based on these conditions?

A. Go to 01 -0HP-4023-FR-1.3, (Response to Voids in the Reactor Vessel) and exit 01-OHP-4023-ES-1.2 B. Stay in 01 -0HP-4023-ES-1.2 and implement 01 -0HP-4023-FR-1.3 concurrently C. Go to 01 -0HP-4023-FR-2.3, (Response to High Containment Radiation Level) and exit 01 -0HP-4023-ES-1.2 D? Stay in 01 -0HP-4023-ES-1.2 and implement 01 -0HP-4023-FR-2.3 concurrently ANSWER: D - Yellow path procedures are implemented concurrently. 2.3 has a higher priority than 1.3 A - Incorrect - 2.3 has a higher priority than 1.3 B - Incorrect - 2.3 has a higher priority than 1.3 C - Incorrect - Yellow path procedures are implemented concurrently.

~~

~~

~~~

~

~~~

~~~~

~

~

~

~~~~

~~~~

2/20/2006 Page 130 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

OHl-4023 Abnorrnal/Emergency Procedure User's Guide Attachment 5 section 5.3 LESSON PLAN/OBJ: RO-C-EOP01/#22 KA - 00WE16 EA2.2 High Containment Radiation Ability to determine and interpret the following as they apply to the High Containment Radiation:

Adherence to appropriate procedures and operation within the limitations in the facility's license and amendments RO/SRO Value - (3.0 / 3.3) CFR - 43.5 / 45.13 SOURCE: AUDIT R023 088 (RO# N/A /SR0#086)

Original KA - W/E16 EA2.1 (2.9/3.3) 2/20/2006 Page 131 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test i'

90. 090

. 01 l/SRO/OWNEW//025000

~~~

2.4.35/(3.3

~~~ / 3.5)//F/3

~~

You are the Unit Supervisor responding to a Unit 2 LOCA and are currently implementing 02-OHP-4023-FR-Z.1, Response to High Containment Pressure. Step 6 of this procedure requires you to place DIS in Service.

Which ONE of the following correctly describes required actions to place the Distributed Ignition System (DIS) in operation?

A!, Direct the AEO to Locally stop the Ice Condenser Air Handling Units and the RO to turn on the Hydrogen Igniters.

B. Direct the AEO to Locally start the Ice Condenser Air Handling Units and the RO to turn on the Hydrogen Igniters.

C. Direct the RO to turn on the Hydrogen Igniters after verifying that the Ice Condenser Air Handling Units have automatically tripped.

D. Direct the RO to turn on the Hydrogen Igniters after verifying that the Ice Condenser Air Handling Units have automatically started.

L~

~~~~

~

~~

~

~~

~

~~

ANSWER: A - The Ice Condenser AHUs are locally stopped when DIS is placed in service to reduce potential ignition sources (defrost units). The Hydrogen Igniters are started in the MCR.

B - Incorrect - The AHUs are shutdown prior to turning on the igniters.

C - Incorrect - The AHUs must be locally shutdown, they do not automatically trip.

D - Incorrect - The AHUs must be locally shutdown, they do not automatically start.

REFERENCE:

RO-C-01000, Ice Condenser System LESSON PLAN/OBJ: RO-C-01000 / #I 2 KA - 025000 2.4.35 Ice Condenser System Emergency Procedures/Plan Knowledge of local auxiliary operator tasks during emergency operations including system geography and system implications.

RO/SRO Value - (3.3 f 3.5) CFR - 43.5 / 45.13 2/20/2006 Page 132 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

.~

91

~~. 091 003/SRO/OWNEW//03400O A4.01K3.3 ~-

/ 3.7)//H/3

~~~

~

Unit 1 is in Mode 6.

The following conditions exist:

- Fuel Handling Area Ventilation System is aligned with flow through the Charcoal Filtet

- Fuel Handling Building Radiation Monitor, R-5 alarm/actuation circuitry has just failed.

- VRS-5000 Fuel Handling Area Monitor is available

- MTI has been called for troubleshooting the R-5 failure.

Which of the following describes the required ACTION, if any, to be taken in order to allow core alterations and fuel movement to continue?

A. Core Alterations and Fuel Movement in the Auxiliary Building must be stopped until the R-5 monitor is repaired.

E?. Core Alterations and Fuel Movement in the Auxiliary Building may continue uninterrupted, since the Fuel Handling Area Ventilation System is already aligned with flow through the Charcoal Filter.

C. Core Alterations and Fuel Movement in the Auxiliary Building may continue uninterrupted, since the VRS-5000 Fuel Handling Area Monitor is available.

Dr Core Alterations may continue but Fuel Movement in the Auxiliary Building must be stopped until the R-5 monitor is repaired.

I_

~-

~.~

~~

~~~ -~

~

~.~

~~~ ~.

~ -~

~~~~~

~

~

~~

ANSWER: D - The Fuel Handling Ventilation System must be operable to conduct Fuel Movement in the Auxiliary Building. Upon receipt of a Fuel Handling Area Radiation -

High signal the fuel handling area supply fans are tripped, thus ensuring a negative pressure within the space. The charcoal filter section bypass dampers also receive a close signal upon receipt of Fuel Handling Area Radiation - High signal (however, these dampers are maintained closed when the required FHAEV train is in operation). Thus failure of R-5 alarm/actuation circuitry makes the FHAEV inoperable (Supply fans won't trip - SR 3.7.1 3.4)

A - Incorrect - Core alterations (In Containment) may continue.

B - Incorrect - The Supply fans will not trip.

C - Incorrect - The VRS-5000 provides indications only so the Supply fans will not trip.

REFERENCE:

Technical Specifications 3.7.1 3 and bases, 01 -0HP-4030-127-037 Data Sheet 3 Step 7.

LESSON PLANlOBJ: RO-C-ADM13/#ADM13.3 KA - 034000 A4.01 Fuel Handling Equipment System (FHES)

Ability to manually operate and/or monitor in the control room:

Radiation levels RO/SRO Value - (3.3 / 3.7) CFR - 41.7 /45.5 to 45.8 2/20/2006 Page 133 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

92. 092 001/SRO/OWNEW//061000 A2.03/(3.1

~

/3.4)//H/3 You are the Unit Supervisor. Unit 2 is at 100% power.

Panel 215 Drop 48 - BATTERY N UNDERVOLTAGE has just alarmed.

Investigation revealed that a metal plate has shorted the battery terminals.

Which one of the following identifies the effects on the operability and capability of the Auxiliary Feedwater System?

A!, The TDAFW Pump will NOT start and the FMO-211, 221,231, & 241 TDAFW to SG Isolation valves are failed in the open position. Declare the TDAFW train inoperable and restore within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

B. The TDAFW Pump will start and the FMO-211, 221, 231, & 241 TDAFW to SG Isolation valves are failed in the open position. Declare the N Train battery inoperable and restore within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

TDAFW Pump Isolation valves are failed in the open position. Declare the TDAFW Pump inoperable and restore within 7days.

C. The TDAFW Pump will NOT start and the MCM-221 & 231 SG Steam supply to D. The TDAFW Pump will start and the FMO-211, 221, 231, & 241 TDAFW to SG Isolation valves are failed in the closed position. Declare the TDAFW train inoperable and restore within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

~

~

~~~~

~

~~~~~~~

~~~

~~

~~~~~~

~~~~~~~

ANSWER: A - The Train N battery supplies power to the TDAFW pump start circuitry, Trip & Throttle Valve, SG FW Valves and Test Valves. The TDAFW pump valves are normally open and so they will fail in the open position. TS 3.7.5 Condition B allows 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

B - Incorrect - The TDAFW Pump will not start. If Train N battery is inoperable the TDAFW pump must be declared inoperable.

C - Incorrect - The SG Steam supply valves are AC powered.

D - Incorrect - The TDAFW pump will not start and the valves are normally open and so fail open.

2/20/2006 Page 134 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

RO-(2-05600 Auxiliary Feedwater System pg. 24, TS 3.7.5 AFW & 3.8.4 DC-Operating LESSON PLAN/OBJ: RO-C-05600/#4 KA - 061 000 A2.03 Auxiliary I Emergency Feedwater (AFW) System Ability to (a) predict the impacts of the following malfunctions or operations on the AFW System and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations:

Loss of dc power RO/SRO Value - (3.1 / 3.4) CFR - 41.5 / 43.5 145.3 / 45.1 3 2/20/2006 Page 135 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

93. 093 002/SRO/OWNEW//075000 A2.02K2.5 /2.7)//H/3 Unit 1 is 100% power and Unit 2 is in Mode 3.

All Unit 1 CW pumps are operating.

Only 2 Unit 2 CW pumps are operating.

The following conditions exist :

- Ann. 223, Drop 18, Travelling Screen DP High - LIT

- Ann. 223, Drop 19, Travelling Screen DP High-High - LIT

- Screen DP is 43".

- Lake Inlet temperature is 75OF Which ONE of the following describes the required actions and the plant impact if these actions are not taken? (1 2-OHP-4022-057-001 Attached)

A. Reduce Power to <78% and Shutdown 2 Unit 1 CW pumps. Continued operation at high DP could cause loss of screens and subsequent clogging of the Main & FW Pump condensers.

B f Reduce Power to <91% and Shutdown 1 Unit 1 CW pump. Continued operation at high DP could cause loss of screens and subsequent failure of the Essential Service Water System.

C. Immediately Trip Unit 1 and Shutdown All CW pumps on Both units. Continued operation at high DP could cause loss of screens and subsequent failure of the Essential Service Water System.

D. Immediately Trip both Unit 2 CW pumps. Continued operation at high DP could cause loss of screens and subsequent clogging of the Main & FW Pump condensers.

~

.~

~~

~~~~

~~

~~~~~~

.~

~~~~~~

~~~

_ _ ~ ~

ANSWER: 6 OHP-4022-057-001 requires that power be reduced to < 91 '10 on unit 1 and 1 CW pump stopped. (Step 5 & Attachment A)

A - Incorrect - This would be the required action if Unit 2 was at 100% with 4 CW pumps running. (Unit 1 has only 3 pumps) (Attachment 6)

C - Incorrect - This action is not required unless level is > 50" or until both units have been reduced to only 2 CW pumps running. (Foldout Page)

D - Incorrect - This action is not procedurally directed. In Mode 3, Stopping all CW pumps would lead to a loss of vacuum.

2/20/2006 Page 136 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

1 -0HP-4022-057,Screen House Degraded Forebay Coni LESSON PLAN/OBJ: RO-C-AOPl l/#AOP11.16 tion Attachment Provided OHP-4022-057,Screen House Degraded Forebay Condition KA - 075000 A2.02 Circulating Water System Ability to (a) predict the impacts of the following malfunctions or operations on the Circulating Water System and (b) based on those predictions, use procedures to correct, control, or mitigate the consequences of those malfunctions or operations:

Loss of circulating water pumps RO/SRO Value - (2.5 12.7) CFR - 41.5 / 43.5.1 45.3 145.13 2/20/2006 Page 137 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

94. 094 012/SRO/OKDIRECT/AUDIT R022-BOTH-2SlGENERIC

-2.3

/3.4)//F/2

~~~~~

~~~

~~

~

~

~~

~~~

.~

~~

~.

The following conditions exist :

- Unit 2 is in Mode 1.

- A Reactor Operator and the Unit Supervisor are in the Unit 2 Control Room.

- A high vibration alarm is received on the HD pump requiring someone to go behind the panel to check the indications.

I Which ONE of the following describes the procedurally accepted method of checking I

the indications?

AY The Unit Supervisor can go behind the panel to check the vibration.

B. The Reactor Operator can go behind the panel to check the vibration.

C. Both the Reactor Operator and the Unit Supervisor are allowed to go behind the panel to check the vibration as long as all controls are in automatic.

D. Neither the Reactor Operator or the Unit Supervisor can go behind the panels.

ANSWER: A - The Unit Supervisor must be in the Control Room but may go behind the panels. The RO must remain in the view of the panels.

B - Incorrect - The RO must remain in the view of the panels.

C - Incorrect - The RO must remain in the view of the panels.

D - Incorrect - The SRO may go behind the panels.

REFERENCE:

OHI-4000, Conduct of Operations Attachment 23 (Shift Staffing)

They must get another operator to check the vibration.

~~

~~

~~~~~

~

~~

~~~~~~~

~ ~ _ _ ~

~~~~~~~~

~ _ _ _ _ ~

~~

~~~~

~~~~~~~~

~~~~~

~~

LESSON PLAN/OBJ: RO-C-ADMOl/#l KA - Generic 2.1.4 Generic Conduct of Operations Knowledge of shift staffing requirements.

RO/SRO Value - (2.3 / 3.4) CFR - 41.1 0 / 43.2 SOURCE: AUDIT R022-BOTH-25 Original Quest. KA - 2.1.4 2/20/2006 Page 138 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test NOTE:

Question 95 contained security-related information that was not publicly available.

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test On-The-Spot Change (OTSC)?

A. Verifies that the change is consistent with appropriate source documentation.

B. Determines that the change is technically correct.

C. Ensures that the change meets equipment engineering requirements.

KA - Generic 2.2.6 Generic Equipment Control Knowledge of the process for making changes in procedures as described in the safety analysis report.

ROiSRO Value - (2.3 / 3.3) CFR - 43.3 / 45.13 SOURCE: Direct 01ADMC12-2 Original Quest. KA - G2.2.6 EXAMIQUIZZES: R023ADMl 2/20/2006 Page 141 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

97. 097 002/SRO/OWDIRECT/O1008C0014-2/GENERIC

-~

._ 2.2.2442.6 /3.8)//F/3

~~

~

~~~~~

~~~

~

Unit 2 is in Mode 1 at 100% power. Maintenance activities require that the North SI pump discharge cross-tie valve must be CLOSED for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />.

What actions must be taken to ensure Technical Specifications AND LOCA analysis requirements protection is provided?

A. Reduce thermal Power to < 3304 MWt.

No other alignment Changes are required.

Place the E RHR pump switch in the pull to lock position.

Place the W RHR pump switch in the pull to lock position Open both RHR discharge x-tie valves, IMO-314 and IMO-324 Place the E RHR pump switch in the pull to lock position.

B. Open both RHR discharge x-tie valves, IMO-314 and IMO-324 C. Open the "E" RHR discharge x-tie valve, IMO-314 D!' Reduce thermal Power to < 3304 MWt.

~~~

~~~

~~

~

~

.~

~~

~~~

~.

~

~~~

~

ANSWER: D - Technical specifications require that both SI Discharge crosstie valves be open. If one valve must be closed then power must be reduced to c 3304 MWt within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. additionally the RHR Crossties must be opened to ensure 4 loop injection. The East RHR pump is placed in PTL to prevent the RHR pumps from overpowering each other.

A - Incorrect - The RHR crossties must be opened.

B - Incorrect - Power must be reduced on Unit 2 to < 3304MWt C - Incorrect - Both crosstie valves must be opened.

REFERENCE:

02-OHP 4021.008.002, ATT. 1, Technical Specification 3.5.2 Condition D and bases.

LESSON PLAN/OBJ: RO-C-00800/#13 KA - Generic 2.2.24 Generic Equipment Control Ability to analyze the affect of maintenance activities on LCO status.

RO/SRO Value - (2.6 / 3.8) CFR - 43.2 / 45.13 SOURCE: Master Bank 01008COO14-2 Original Quest. KA - 006 K6.02 EXAM/QUIZZES: R01821; Q2703V; RQ2526C-R/S; R022EOP5A 2/20/2006 Page 142 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~ 98. 098 003/SRO/OWDIRECT/AUDIT R023

_ ~ _ _

Q#88/GENERIC 2L3,6E/-3,1...

~~~~

Rad monitor VRS-1505, Unit Vent Effluent Low Range Noble Gas Channel, has failed HIGH. Repairs will take at least 3 days.

Which ONE of the following actions is required by PMP-6010-OSD-001, Off-site Dose Calculation Manual, regarding a release from the waste gas decay tank?

References Attached:

PMP-6010-OSD-001, Off-site Dose Calculation Manual, Attachment 3.4 (pages 50-52)

The release...

A. may NOT be started until the repairs on VRS-1505 are completed B. may be started provided RP recalculates the trip set points using VRS-2505 as the C. may be started for up to 30 days provided grab samples are taken shiftly and De may be started for up to 14 days provided 2 independent samples are analyzed and ANSWEE-D- -PMP-601O-OSD-OOl Attachment 3.4 Action 9 allows releases to continue for 14 days provided 2 independent samples are analyzed and the calculations and valve lineups are dual verified.

A - Incorrect - Action 9 allows releases to continue.

B - Incorrect - Additional Actions are required to allow releases. The VRS-2505 monitors the Unit 2 vent stack.

C - Incorrect - Additional Actions are required to allow waste gas releases. These actions are for normal operation.

release path alarm and termination monitor.

analyzed within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

the calculations and valve lineups are dual verified.

~

~~~~~~~

~ ~ _ _

-~~~

~~

~~~~~

~

~~~

~

~~

~

2/20/2006 Page 143 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

REFERENCE:

PMP-6010-OSD-001,Off-site Dose Calculation Manual, Attachment 3.4 (pages 50-52)

Attachment Provided - PMP-6010-OSD-001, Off-site Dose Calculation Manual, Attachment 3.4 (pages 50-52)

LESSON PLAN/OBJ: RO-C-ADM1 O/#ADM10.5 KA - Generic 2.3.6 Generic Radiological Controls Knowledge of the requirements for reviewing and approving release permits.

RO/SRO Value - (2.1 / 3.1) CFR - 43.4 / 45.10 SOURCE: Direct R023-93-3 (RO# N/A /SRO#088)

From AUDIT02-SR025 Original Quest. KA - APE 060 G 2.3.8 (2.3/3.2) 2/20/2006 Page 144 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

99. 099 00 lISRO/OWDIRECT-INPOIINNA 2004-27356/GENERIC~,!.8/(2.3 I 3.2)llFmP.~ ~.

~~~~

.~

The maximum time that can elapse between a gas decay tank being approved for release and the start of the release is...

A. 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> B. 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> C!' 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> D. 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br />

~~.

ANSWER: C OHP-4021-023-002 Release of Radioactive Waste from Gas Decay Tanks, Data Sheet 1 requires the SRO to ensure that not more than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> have elapsed since the Release was approved.

A - Incorrect - 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> is allowed. 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> is the required time for estimated sample flow if rad flow monitors are inoperable.

6 - Incorrect - 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> is allowed. 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> is the typical shiftly surveillance time.

D - Incorrect - 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> is allowed. 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> is the time allowed to reduce the GDT concentration if it exceeds 43,800 Ci.

REFERENCE:

12-OHP-4021-023-002 Release of Radioactive Waste from Gas Decay Tanks, Data Sheet 1 LESSON PLAN/OBJ: RO-C-ADMO1/#21 KA - Generic 2.3.8 Generic Radiological Controls Knowledge of the process for performing a planned gaseous radioactive release.

RO/SRO Value - (2.3 / 3.2) CFR - 43.4 / 45.1 0 SOURCE: INPO # 27356 Ginna 1 - 4/27/2004 Original Quest. KA - 2.3.6 2/20/2006 Page 145 of 146

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test 1 00. 100 002/SRO/OWDIRECT-INPOfl)lABLO CYN2002-225 1OlGENERIC 2 4 28/(2 3133)//H/2---

r-U n i t 1 was in MODE 4 doing; Containment Inspection.

1 An explosive device was found in close proximity to the Main Steam Leads.

How should the this event be classified per the Emergency Plan? (PMP-2080-EPP-101 is attached)

A. General Emergency BY Site Area Emergency C. Alert D. Unusual Event ANSWER: B - Security event H-2 requires a Site Area Emergency if a bomb is found within the Vital Area.

A - Incorrect - This applies if the ability to reach Mode 5 is lost.

C - Incorrect - This applies to a security event in the protected area - Intrusion or civil disturbance.

D - Incorrect - This applies to an explosive device in the protected but not vital area.

Containment is a Vital area

~

-~

~~~~~

~~~~~~~~

REFERENCE:

PMP-2080-EPP-101 Attachment 1 pg. 14 & Attachment 3 pg. 48 Attachment Provided - PMP-2080-EPP-101 Attachment 1 NOTE - PMP -2080-EPP-101 should not be placed in Public record. NRC EAL Security Advisory.

KA - Generic 2.4.28 Generic Emergency Procedures/Plan Knowledge of procedures relating to emergency response to sabotage.

RO/SRO Value - (2.3 / 3.3) CFR - 41.10 / 43.5 / 45.13 LESSON PLAN/OBJ: ST-C-EP03/#2 SOURCE: INPO # 22510 Diablo Canyon 1 - 10/1/2002 Original Quest. KA - 007.2.4.28 2/20/2006 Page 146 of 146

~-

1 2

3 4

5 6

7 8

9 IO I 1 12 13 14 1s 16 17 18 19 20 21 22 23 24 2s 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44

~~

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test Page 1 of 3

45 46 47 48 49 so SI 52 53 54 55 56 51 59 60 61 62 61 64 65 66 61 68 69 10 71 72 73 14 75 76 17 78 79 SO 81 83 84 85 86 87 88 58 82 A

B B

A A

B D

A C

C C

C C

D C

B B

B A

B A

B C

D B

B C

B C

B C

D A

C D

A B

B A

D B

C B

C 2/20/2006 Page 2 of 3

DC Cook 2006 NRC ILT Written Examination 2006 SRO Submitted Test

~

~

~

~- ~.

89 D

90 A

91 D

92 A

93 B

94 A

95 D

96 D

97 D

98 D

99 C

I00 B

2/20/2006 Page 3 of 3