NRC COMMENTS TO THE INITIAL EXAM SUBMITTAL INCLUDING WRITTEN EXAM COMMENTS ON ES-401-9 AND OPERATING TEST COMMENTS FOR THE D. C. COOK INITIAL EXAMINATION - FEBRUARY 2006

JEzlZl u/E/s I Explanation II iits I ward r KIA Only X

E Bank. 1) To enhance distractor A, change it to say: "Ensure incoming voltage is slightly higher than running voltage prior to closing the output breaker." 2) Distractor B is not plausible that one matches running and incoming currents prior to closing the DG output breaker. Suggest changing this to say: 'Ensure synchroscope is at the 12 o'clock position prior to closing the output breaker." This wording for the distractor would also provide for symmetly in the distractors.

RESOLUTION: Comments incomorated.

II S

Bank.

E Bank. Editorial: In distractors C and D. add the word "is" before the word 'still". RESOLUTION: Comment incorporated.

Bank. Edltorial: In the question stem. fully Capitalize the word "ONE" (i.e.. Which ONE of the following... ).

RESOLUTION: Comment incorporated.

E X

S Bank.

S Bank.

E Bank. Editorial: Fully capitalize the word "ONLY" in distractors A, B, and C. RESOLUTION: Comment incorporated.

Bank. 1) Distractor A is not plausible that one could operate in any Mode with all ECCS LCOs satisfied, with an SI pump inoperable.

2) Editorial: In the question stem, fully capitalize the word "ONE" (i.e.,

Which ONE of the... ).

RESOLUTION: 1) Changed distractor A to state that it is OK to go to Mode 3, but may not proceed to Mode 2. 2) Comment incorporated.

Bank. 1) The provided reference does not show the requirement to isolate the #12 SG blowdown. It appears that distractor C is also incorrect, and there is no correct answer. 2) This question should be classified at the Higher Cognitive Level instead of at the Fundamental level.

RESOLUTION: 1) Changed distractor C to state to isolate SG blowdown.

which is consistent with the calorimetric procedure.

2) Comment incomrated.

X U

S Bank.

ES-401 Written Examination Review Worksheet Form ES-401-9 Explanation be taken? to Which ONE of the

[Refer to Section D of ES-401 and Appendix B for a ormation regarding each of the following concepts.]

Enter the level of knowledge (LOK) of each question as either (F)undamental or (H)igher cognitive level.

Enter the level of difficulty (LOD) of each question using a t - 5 (easy - difficult) rating scale (questions in the 2 - 4 range are acceptable).

Check the appropriate box if a psychometric flaw is identified:

The stem lacks sufficient focus to elicit the correct answer (e.g., unclear intent, more information is needed, or t w much needless Information).

The stem or distractors contain cues (&e.. clues, specific determiners, phrasing, length, etc).

The answer choices are a collection of unrelated truelfalse Statements.

The distractors are not credible; single implausible distractors should be repaired, more than one is unacceptable.

One or more distractors is (are) pallially correct (e.9.. if the applicant can make unstated assumptions that are not contradicted by stem).

The question is not linked to the job requirements (i.e., the question has a valid WA but, as written, is not operational in content).

The question requires the recall of knowledge that is too specific for the closed reference test m d e (i.e., it is not required to be known from memory).

The question contains data with an unrealistic level of accuracy or inconsistent units (e.g., panel meter in percent with question in gallons).

The question requires reverse logic or application compared to the job requirements.

Check the appropriate box if a job Content error is identified:

Check questions that are sampled for conformance with the approved WA and those that are designated SRO-only (WA and license level mismatches are unacceptable).

A + in the QV column indicates that question was reviewed as part of the representative sample of 30 questions.

ES-401 2

Form ES-401-9 Quad Cities May 2005 Exam

5. Other
6.
7.

O= ISRO UIEIS Emlanation UA ]only I I

I S

Bank.

Bank. Editorial: In distractor D. change the first word from "Maintain" to l E l

-Maintains."

RESOLUTION: Comment incorporated.

S Bank.

X E

Bank. 1) In the question stem, add another condition that states that "RCS temperatures are at 150°F". 2) In distractor D. change "reliefs" to

'relief", since there is only one RHR suction relief valve.

RESOLUTION: Comments incorporated.

S Bank.

S Bank.

U New. Need references to verify that the second sentence in distractor D is correct (i.e., concerning 120 gpm of borated RWST water).

RESOLUTION: Comment incorporated. Changed the last sentence in distractom A and D to reference 7 0 gpm" instead of '120 gpm".

S Bank.

X E

Moa Ilea State tnat me leakage rate s 100 gpm instead of 150 gpm, an0 lhal RCS pressJre 6 1350 ps g instead 01 1700 ps g Tnen change Ine 0 straclors 10 A) Approx 25 gpm. B) Approx 50 gpm (Correct Ansuer,.

C ) Approx 75 gpm. ana D, Approx 100 gpm RESOLUTION Comment ncorporatec To make the math s mpler, change me qbest on slem IO S

Mooiliea X I I S IBank.

II

~

I S

Bank.

U

W 3

X X

v)

N Y

m -

X W

m U.

0 N

3 X -

X N

LL

+

m N -

- t

W m

I N

m

m I

3 X

X m

Y

+

u) m

W X

N Y

r. m I =

I -

N W

m 0

(1

6 u / u s word "should to 'bould".

7 Explanation S

Bank.

S New.

E New. In the question stem, add the words "assuming NO operator action" to the question.

RESOLUTION: Comment incorporated.

7 L

Ban6 rao atton mon tors are on y energ zed wnen tne SG PORV opens

2) D stractor B an0 C are not p aus b e tnat me SG P O W rao mon tors would be mountW upstream 01 the SG PORVs on a not pope RESOLUTION 11 Replaced this pnrase witn one asmg wnetner the mondors are reliable only n non accident conditions or also aher an accident 2) Comment incorporated Changea mountea" lo "posdioned.

1, Distractors Aano Bare not pa~siole that the SG PORV X

E New. Editorial: In the question stem, change I...

level will initially..." to

"... levels will initially..,".

RESOLUTION: Comment incorporated.

Modified. Distractors E and D state that the turbine trips, but the status of the turbine is not stated in the question stem. Suggest saying in the question stem that the turbine is at 1800 rpm and ready to go online.

RESOLUTION: Comment incorporated.

E S

Bank.

S Bank.

1 X

S Modified.

S Bank.

U Bank. There would be overlap between this question and the actions performed during JPM 2006-INPL 3, since the first step that the applicant would perform in the JPM would be to cycle the battery charger switch to OFF and then back to AUTO.

RESOLUTION: Replaced question (Bank, H, 2).

I w X

I

2.
3. Psychometric Flaws E

S

4. Job Content Flaws New. 1) Change the question stem so that there is a loss of CRlD 111 instead of CRlD 1, since otherwise one could guess that distractor B is the correct answer (loss 01 N21) without even knowing the reason why it is correct. 2) Editorial: In the question stem, fully capitalize the word "ONE" (i.0.. Which ONE of the following...).

RESOLUTION: Comments incorporated.

Q:

Question requires a reference.

Bank.

unit:

81 82 83+

84 85 86+

87 88 89+

90 91

5. Other H

F H

H H

H H

H H

H H

J/E/S 6' I S

7.

Explanation Modified S

E E

S S

]Bank.

II Modified.

NOTE: Question requires a reference.

Bank. 1) Editorial: In the question stem. add the word 'now" so that the sentence reads The crew has

2) In the question stem. change the phrase "should be running" to "are expected to be running".

RESOLUTION: Comments incorporated.

NOTE: Question requires a reference.

Modified. In the question stem. change SG #I3 NR Level from 93% to 96%. so that the applicant is not required to know the exact setpoint of 92% as the cutoff for high SG level actions.

RESOLUTION: Comment incorporated.

Rank reached step 12...".

U E

Bank. This question is assmiated with WA WE16 EA 2.2, which is not on the Written Exam Outline.

RESOLUTION: Replaced question (Bank, H, 3).

New. 1) This question should be classified at the Higher Cognitive level instead of at the Fundamental level. 2) Put the phrase "Direct the RO lo turn on the Hydrogen Igniters" in the question Stem, instead of repeating S

this phrase in-each distractor.

RESOLUTION: Comments incorporated.

New.

E 92 93+ -

94 95 -

96c 97 -

98 -

99+

100 -

=

Deleted mention of 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> and 7 day LCOs from the

DC COOK FEBRUARY 2006 INITIAL LICENSE EXAM OPERATING EXAM COMMENTS

~

Comment This JPM really has only one Critical Step (to identify that there are no misaligned rods). There is no Critical Step associated with the KIA for the JPM (KIA 2.1.25 associated with the ability to interpret graphs and tables). To make the JPM correspond to KIA 2.1.25 and to increase the level of difficulty, make the following changes:

1) Change the initial rod positions so that one control rod is actually misaligned (and have the RO who filled out the form show that no control rod is misaligned).
2) Change the initial conditions such that one control rod was found to be untrippable during the quarterly surveillance conducted per SR 3.1.4.2.

Have the RO fill out the Incorrect Worth of a Single Stuck R o d in step 4.5.2 (use 121 pcm instead of 825 pcm, which would correspond to using the wrong graph in Figure 1.3b).

[NOTE: JPM A initially Unsatisfactory]

1) On page 5, it states as a Crltical Task that the applicant identifies that the AFD has been outside the Target Band for at leaat 30 minutes. Change from for at least 30 minutes to between 30 minutes and 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, since only the 1230 hours0.0142 days <br />0.342 hours <br />0.00203 weeks <br />4.68015e-4 months <br /> AFD readings show two channels outside the Target Band (and the applicant could conservatively assume that there were two channels outside the Target Band for up to one hour).
2) Add to the second Critical Task on page 5 that the applicant identifies that a Tech Spec 3.2.3 entry is required. [Comment during onsite validation]

Change the Critical Tasks so that they are:

1) There is a sequencing error in that the fuse and breaker are taken 00s before the MCB switch is placed in LOCKOUT.
2) There is no tag listed for the East ESW pump discharge valve.

Resolution

omments incorporated.
omments incorporated.

1

DC COOK FEBRUARY 2006 INITIAL LICENSE EXAM OPERATING EXAM COMMENTS On page 5, change the wording of the second sentence of the Critical Step to say: Slope of curve indicates rate of rise of leakrate exceeds 30 GPDlhr (since the lines on the graphs indicate a rate of leakrate increase of 30 GPDhr, not a leakrate of 30 GPD).

Komment durina onsite validationl Source Comment incorporated.

Admin JPM D Delete the Table of SJAE radiation readings on the Task BriefinQ page handed to the applicant, and instead put the readings on Data Sheet 1.

On page 10, change the first Critical Task to delete the following as Critical Tasks:

- Name

- Call Back#

1) On page 10, only one of the 4-hour 10CFR50.72 notification boxes (Le,, either the ECCS Discharge to R C S or the RPS Actuation box is required to be checked as a Critical Step. Change the Task Briefing such that the event (stuck open SG #12 safety valve with manual safety injection) occurs in Mode 3 at full RCS temperature and pressure (instead of at 100% power), so that the applicant must identify that the 4-hour 10CFR50.72 notification box ECCS Discharge to R C S is required to be checked as a Critical Step.

Admin JPM D Comment incorporated.

Comment incorporated.

Comments incorporated.

Admin JPM E On page 10, the step to direct the AEO to OPEN valve 1-IRV-60 should be a Critical Step.

Admin JPM E Comment incorporated.

JPM A Simulator JPM A Simulator JPM B Simulator Comment I

Resolution On page 4, after the sentence that states Operator attempts to start BOTH BAPS, add the following:

Neither BAP will start Comment incorporated.

_ _ _ ~

~

On page 5, change the last Critical Step from raising Charging flow to L 100 gpm to raising Charging flaw to L 170 gpm, since initially Charging flow will be about 120 gpm.

lComment durina onsite validationl Comment incorporated.

2

DC COOK FEBRUARY 2006 INITIAL LICENSE EXAM OPERATING EXAM COMMENTS

11.
  1. I Source JPM B Simulator
12.

JPM B Simulator Simulator Simulator Simulator Simulator Simulator Simulator 1 Comment In the Task Briefing, change the requirement for the applicant to raise SI Accumulator from 940 ff to 945 ff to make the level closer to normal accumulator level.

[Comment during onsite validation]

On page 9, make the step that starts the South SI pump a Critical Step, since this step is required for the successful performance of the task.

[Comment during onsite validation]

Place the CUE given on page 1 (concerning all procedural precautions and limitations being met) on the Task Briefing page also.

[Comment during onsite validation]

On page 8, in the Ctitical Step where the Operator places 2A5 Control switch in CLOSE, delete and Verifies SYNCH Permissives white light lit.

Reason: This part of the Critical Step is just a verification, and also it is a duplicate of the operator action listed iust below the Critical Stem On page 5, add a NOTE for the Evaluator that the applicant is expected to depress the Emergency Fire System Siren Test pushbutton to sound the fire siren. Also, add a CUE that if the applicant does not depress the pushbutton, say that one does not hear the fire siren.

[Comment during onsite validation]

On page 5, add a NOTE that the applicant is expected to notify the fire brigade by calling extension 1411.

lComment durina onsite validation1

~

On page 1, make the step that locally opens valve 2-FRV-256 a Critical Step.

[Comment during onsite validation]

On page 2, make the step that locally opens valve 2-FW-263 a Critical Step.

[Comment during onsite validation]

On page 2, step 4.10.2, In the suweillance procedure provided, the IST MIN and MAX times are already filled in. Make the applicant find the correct times to put In the spaces, and make this a Critical Step to put in the correct times?

Resolution Comment incorporated.

Comment incorporated.

Comment incorporated.

Comment incorporated.

Comment incorporated.

3

DC COOK FEBRUARY 2006 INITIAL LICENSE EXAM OPERATING EXAM COMMENTS JPM K In-Plant JPM K In-Plant

20. -

On page 4, add the following words at the beginning of the first CUE: (If Asked).

On page 6, in the Evaluator Note at the top of the Dage, change Train A to Train B.

Source JPM G Simulator JPM K In-Plant JPM K In-Plant Comment Add to the Task Briefing that the external fault caused a reactor trip 20 minutes ago.

[Comment during onsite validation]

On page 6, change the last CUE on the page to:

(If asked) There was no loss of offsite power.

On page 7, the second CUE from the bottom should say LIT instead of NOT LIT.

21.
22.
23.

JPM G Simulator JPM G Simulator JPM J In-Plant On pages 7 and 9, delete the Critical Steps associated with adjusting RCP seal injection flow to 6 - 12 gpm, and just say to verify that RCP seal injection flow is 6 - 12 gpm (since no adjustment of RCP seal injection flow Is required).

lComment durina onslte validation1 On page 13, add a CUE that the UV alarms on Panel 221 Drop 67 &68 are NOT LIT.

[Comment during onsite validation]

On page 4, need to add to the CUE at the bottom of the Daae that stew 3 through 7 are complete.

On page 6, correct typo in NOTE:... valve

e.
25. -
26.
27. -
28.

~

29.

Scenario 06-01 Page 2 Editorial:

1) In the first sentence In the Summar. delete the extra will involve phrase.
2) In the first sentence In the 3rd paragraph, change will fail closed to failing closed.
3) In the first sentence in the4th paragraph, change failina to fails.

Resolution Comment incorporated.

Comment incorporated.

Comment incorporated.

Comment incorporated.

Comment incorporated.

Comment incorporated.

Comment incorporated.

Comment incorporated.

Comment incorporated.

Comments incorporated.

A

DC COOK FEBRUARY 2006 INITIAL LICENSE EXAM OPERATING EXAM COMMENTS Source Scenario 06-01 Event 1 Page 4 Scenario 06-01 Event 3 Page 6 Scenario 06-01 Event 3 Page 6 Scenario 06-01 Page 0 Scenario 06-01 Page 9 Scenario 06-01 Page 9

~~

Scenario 06-01 Page 10 Comment

1) Change Tech Spec 3.3.4 from Does NOT apply to Table B 3.3.4-1, Function 2, Condition A, 30 day clock.
2) Add to TS 3.5.2 Condition A, 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> clock.
3) Add to TRM 8.1.1 Condition A, 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> clock.

[Comments during onsite validation]

1) Delete the NOTE about the SM directing the crew to restore 75 gpm letdown, since the Unit Supervisor should direct this action (or add a CUE for the booth as the SM).
2) Editorial: In item 12), add an open parentheses before if desired).
1) In the steps for the RO to restore letdown, place the step to adjust charging flow to 75 gpm after the step that adjusts the letdown pressure controller to 75%.
2) After adjusting charging flow to 75 gpm, add steps that would allow the RO to place a second letdown orifice (45 gpm) in service.

[Comments during onsite validation]

In the place where It states for the US to Directs RNO actions for Step 5 of E - 0, add at the end what Step 5 does.

The Critical Task #1 on this page says to isolate ALL MSIVs, whereas on page 11 it states that the Critical Task is to only close the #24 MSIV. Only closure of 824 MSIV should be a Critical Task.

1) Editorial: Change Opens 2-lMO-221,2E CTS Pump Discharge Valve to Opens 2-lMO-221,2W CTS Pump Discharge Valve.
2) Change valve 2-IMO-202 to 2-IMO-204.

[Comment during onsite validation]

On page 10, add a NOTE that verification of the six valves closed is not a Critlcal Step.

lComment durina onsite validation1 Resolution Comments incorporated.

Comments incorporated.

Comments incorporated.

Comment incorporated.

Comment incorporated.

Comments incorporated.

5

DC COOK FEBRUARY 2006 INITIAL LICENSE EXAM OPERATING EXAM COMMENTS Source 1;: 1 Scenario06-01 Page 10 Scenario 06-01 Page 11 Scenario 06-02 Page 7 Scenario 06-02 Page 8 Comment Add the first 9 steps of ES-1.1 to the end of the scenario. [Comment during onsite validation]

Delete mention of MNV valves and SGBD sample valves from the Performance Indicetors for Critical Task #1.

Change the magnitude of the SGTR from 300 gpm to 400 gpm. [Comment durlng onsite validation]

In the Event Description, change fails HIGH to fails LOW.

~

~

~

Edltorial: Change Bend to Blend in middle of page.

1) It states that the crew may enter the Excessive RCS Leakage procedure. The crew may also enter the SG Tube Leak procedure. Add that the crew may also enter the SG Tube Leak procedure.
2) In the sentence where it states for the US to direct ROlBOP to perform the immediate actions of E-0, add before this that the US directs RO/BOP to manually trip the reactor and Initiate safety injection (e.g., see wording In Scenario 06-03).
1) Editorial: Put E-0 on the next line when the US announces a transition to E-0.
2) When the US directs operator actions to close the SO PORV, delete the Phrase and monitor Reactor Power.
3) Editorial: For the actions for Critical Task #2, change SO 23 to SO 22.
4) Add to Critical Task #2 to close the Stop Valve Dump Valves. [Comment during onsite validation]

Instead of terminating the scenario when the RCS depressurization is started, continue the scenario further until the depressurization has been stopped and SI has been terminated.

Resolution Comment incorporated.

Comment incorporated.

Comment incorporated.

Comment incorporated.

Comment incorporated.

Zomments incorporated.

omment incorporated.

6

DC COOK FEBRUARY 2006 INITIAL LICENSE EXAM OPERATING EXAM COMMENTS Source Scenario 06-02 Page 9 Scenario 06-02 Page 10 Scenario 06-02 Page 10 Scenario 06-02 Page 10 Scenario 06-02 Page 13 Scenario 06-03 Page 1 Scenario 06-03 Page 2 Scenario 06-03 Event 1 Page 3 Scenario 06-03 Page 9 Comment

~

~

Editorial: For Critical Task W, change SG 23 to SG 22 in three places.

For Critical Task #1, add (Train E) to the Performance Indicator associated with manually starting ECCS Equipment.

lComment during onsite validationl For Critical Task 82, delete Ensures feed flow isolated from the Performance Indicator.

[Comment during onslte validation]

For Critical Task #4, what is the acceptance criteria associated with not risking the consequences of SG overflll?

Editorial: Under Simulator Instructions, Change

  1. 24 S G to #22 S G just below middle of page.
1) On the Scenario Outline sheet, add to the Turnover that the SM wants the crew to raise Reactor Power to 70%.
2) Move Event 3 (Raise Turbine and Reactor Power) to Event 1 before any malfunctions are inserted. [Comment durlng onsite validation]
3) Delete Event 8, since the failure of DG 2AB to start does not significantly affect the scenario.

~

~

Editorial: In the last line of the 3rd paragraph, delete the words to the.

Add a statement to reopen the CCW Surge Tank vent valve per the ARM if the valve closes.

[Comment during onslte validationl

1) For Critical Task 91, opening BIT inlet valve 256 should not be a Critical Task, since the redundant BIT inlet valve is already open.
2) The Critical Task should be to open BIT outlet valve 250 parallel.
3) For Critical Task #2, add the requirement that the RCPs are tripped within 5 minutes of the trip criteria beina satisfied (as Der Daae 12).

251, since these valves are in Resolution Comment incorporated.

Comment incorporated.

Added as an acceptance criteria that the ruptured SG inventory remains below 44 feet per ComDuter Point RCLSG2.

Comment incorporated.

1) Comment incorporated.
2) Comment incorporated.
3) Event 8 was combined with Event 7 as one malfunction.

_ _ _ _ _ ~ ~

Comment incorporated.

Comment incorporated.

7

54. -
55.
56.
57.
58.
59.
60.

Comment DC COOK FEBRUARY 2006 INITIAL LICENSE EXAM OPERATING EXAM COMMENTS Resolution Source After SI is reset in ES-1.1, delete item 5 which says to open the control air valves to containment.

[Comment during onsite validation]

Editorial:

1) In the last line of the 2w paragraph, delete the period (.) After Technical Specifications.
2) On the last line of the last paragraph, change ECAO.l to ECA-0.1.

Scenario 06-03 Page 10 Scenario 06-04 Page 2 Comment incorporated.

Comments incorporated.

Scenario 06-04 Event 3 Page 5

1) Change the Event Description to #4 Boric Acid Pump Trip (and also change the Scenario Outline sheet).
2) Add to the first line associated with the RO action to Verifies #4 Boric Acid Pump has tripped.
3) After TRO 8.1.1, add (No entry to Condition A).

[Comment during onsite validation]

Make a separate page for Event 4a and Event 4b.

1) Critical Task #2 should be located right after Critical Task #1 on page 10 (after Bus T21A is energized).
2) Editorial: Add space between actionsas directed.
3) For scenario termination, one would need to continue into ECA-0.2, If Bus T21A is not energized when entering ECA-0.2. Add the initial steps of ECA-0.2 at the end of the scenario, in case Bus T21A is not energized when entering ECA-0.2.

Add to the list of pumps to place in pull to lock the ESW pumps (non-running).

[Comment during onslte validation]

Add to the Simulator Inlitructions that If contacted as Unit 1 to verify HSDP #4 BA Pump position, report that the swltch is in the Control Room position.

[Comment during onsite validation]

Scenario 06-04 Event 4d4b Page 6 Comments incorporated.

Comment incorporated.

Comments incorporated.

Comment incorporated.

Comment incorporated.

Scenario 06-04 Page 11 Scenario 06-04 Page 12 Scenario 06-04 Page 18 8

61. -
62.
63.
64.
65.
66.
67.
68.
69.

~~

Scenario 06-05 Page 2 DC COOK FEBRUARY 2006 INITIAL LICENSE EXAM OPERATING EXAM COMMENTS

~

1) In the 2"" paragraph on the Summary page, in the first sentence, add the word "Range" after the word "Power".
2) In the 2-paragraph on the Summary page, the second sentence needs to be changed, since one does not select an operable channel, and restore pressure control to automatic for a Power Range channel failure.

Source I

Comment Scenario 06-05 Event 3 Page 6

~

~

~

Move step to locally isolate CCW to Letdown HX valves 2-CCW-160,164, and 165 to after placing excess letdown in servlce to agree with the order in the procedure.

[Comment during onslte validationl Scenario 06-05 Event 1 Paae 4 failure. [Comment durina onsite validationl Add Tech Spec Condition C to the list of condition entries for TS 3.3.1 for Power Range channel N142 Scenario 06-05 Event 4 Page 7 Scenario 06-05 Event 3 Page 6 For the failure low of the Main Steam Turbine Header pressure transmitter, add an option for the BOP to control MFW flow by placing both MFW Pumps in Manual.

[Comment durlng onslte validationl When placing excess letdown in service, delete mention of opening 2-QRV-161 letdown orifice isolation valve.

[Comment durina onslte validationl Scenario 06-05 Page 9 Scenario 06-05 Page 9 Add step for RO to try to start the 2W CCP, but it fails to start.

Make the step to trip ail RCPs a part of Critical Task #2 (to agree with Its designation as part of Critical Task #2 on page 11).

[Comment durina onsite validationl

~

~

Scenario 06-05 Page 11 Scenario 06-06 Event 4 Page 6 For Critical Task #1, it states that there is a challenge to multiple reactor trip setpoints PZR pressure safety Injection. This should be changed to only list the SO lo lo level and SO FF/SF mismatch with lo level reactor trips for a Editorial: In the Event Description, change "SG 21" to "SO 22" and "FFC-210" to "FFC-220".

1. including Low PZR pressure reactor trip and Low 1 loss of FW event.

I Resolution Comments incorporated.

Comment incorporated.

Comment incorporated.

Comment incorporated.

Comment incorporated.

Comment incorporated.

Comment incorporated.

~~

Comment incorporated.

Comment incorporated.

9

Source Comment I

Resolution 10

70.

Scenario 06-06 Page 7 For Critical Task X2, add the requirement that the RCPs are tripped within 5 minutes of the trip criteria being satisfied (as per page 9).

Comment incorporated.