January 17, 2006 Mr. Richard Anderson Vice President FirstEnergy Nuclear Operating Company Mail Stop A-PY-A290 P.O. Box 97, 10 Center Road Perry, Ohio 44081
SUBJECT:
PERRY NUCLEAR POWER PLANT, UNIT 1 - REQUEST FOR ADDITIONAL INFORMATION RELATED TO OSCILLATION POWER RANGE MONITORS (TAC NO. MC7489)
Dear Mr. Anderson:
By letter to the Nuclear Regulatory Commission (NRC) dated July 5, 2005, FirstEnergy Nuclear Operating Company submitted a request for a license amendment to modify the existing Technical Specification 3.3.1.3, Oscillation Power Range Monitor (OPRM) Instrumentation, Surveillance Requirement 3.3.1.3.5, for the Perry Nuclear Power Plant, Unit 1.
The NRC staff is reviewing your submittal and has determined that additional information is required to complete the review. The specific information requested is addressed in the enclosure to this letter, and was forwarded to your staff on November 30, 2005. During a discussion with your staff, it was agreed that you would provide a response 120 days from the date of this letter.
The NRC staff considers that timely responses to requests for additional information help ensure sufficient time is available for staff review and contribute toward the NRCs goal of efficient and effective use of staff resources. If circumstances result in the need to revise the requested response date, please contact me at (301) 415-1496.
Sincerely,
/RA by S.Sands for/
Kahtan N. Jabbour, Senior Project Manager Plant Licensing Branch III-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-440
Enclosure:
As stated cc w/encl: See next page
Mr. Richard Anderson January 17, 2006 Vice President FirstEnergy Nuclear Operating Company Mail Stop A-PY-A290 P.O. Box 97, 10 Center Road Perry, Ohio 44081
SUBJECT:
PERRY NUCLEAR POWER PLANT, UNIT 1 - REQUEST FOR ADDITIONAL INFORMATION RELATED TO OSCILLATION POWER RANGE MONITORS (TAC NO. MC7489)
Dear Mr. Anderson:
By letter to the Nuclear Regulatory Commission (NRC) dated July 5, 2005, FirstEnergy Nuclear Operating Company submitted a request for a license amendment to modify the existing Technical Specification 3.3.1.3, Oscillation Power Range Monitor (OPRM) Instrumentation, Surveillance Requirement 3.3.1.3.5, for the Perry Nuclear Power Plant, Unit 1.
The NRC staff is reviewing your submittal and has determined that additional information is required to complete the review. The specific information requested is addressed in the enclosure to this letter, and was forwarded to your staff on November 30, 2005. During a discussion with your staff, it was agreed that you would provide a response 120 days from the date of this letter.
The NRC staff considers that timely responses to requests for additional information help ensure sufficient time is available for staff review and contribute toward the NRCs goal of efficient and effective use of staff resources. If circumstances result in the need to revise the requested response date, please contact me at (301) 415-1496.
Sincerely,
/RA by S.Sands for/
Kahtan N. Jabbour, Senior Project Manager Plant Licensing Branch III-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-440
Enclosure:
As stated cc w/encl: See next page DISTRIBUTION:
PUBLIC LPLIIII-2 R/F RidsNrrPMKJabbour RidsOGCRP RidsNrrLADClarke RidsRgn3MailCenter RidsNrrDorlLplF RidsAcrsAcnwMailCenter DORL DPR GHill (2)
SCampbell RidsNrrDssSnpb Accession Number: ML060060484 OFFICE NRR/LPL3-2/PM NRR/LPL3-2/PM NRR/LPL3-2/LA DSS/SNPB/BC NRR/LPL3-2/BC (A)
NAME SCampbell KJabbour:mw DClarke FAkstulewicz MLandau DATE 1/13/06 1/13/06 1/15/06 1/17/06 1/17/06 OFFICIAL RECORD COPY
Perry Nuclear Power Plant, Unit 1 cc:
David W. Jenkins, Attorney FirstEnergy Corporation Mail Stop A-GO-18 76 South Main Street Akron, OH 44308 Resident Inspector's Office U.S. Nuclear Regulatory Commission P.O. Box 331 Perry, OH 44081-0331 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 2443 Warrenville Road Lisle, IL 60532-4531 Sue Hiatt OCRE Interim Representative 8275 Munson Mentor, OH 44060 Manager - Regulatory Compliance FirstEnergy Nuclear Operating Company Perry Nuclear Power Plant P.O. Box 97, A210 10 Center Road Perry, OH 44081 Mayor, Village of North Perry North Perry Village Hall 4449 Lockwood Road North Perry Village, OH 44081 Donna Owens, Director Ohio Department of Commerce Division of Industrial Compliance Bureau of Operations & Maintenance 6606 Tussing Road P.O. Box 4009 Reynoldsburg, OH 43068-9009 Carol OClaire, Chief, Radiological Branch Ohio Emergency Management Agency 2855 West Dublin Granville Road Columbus, OH 43235-7150 Mayor, Village of Perry P.O. Box 100 Perry, OH 44081-0100 Dennis Clum Radiological Assistance Section Supervisor Bureau of Radiation Protection Ohio Department of Health P.O. Box 118 Columbus, OH 43266-0118 Zack A. Clayton DERR Ohio Environmental Protection Agency ATTN: Mr. Zack A. Clayton P.O. Box 1049 Columbus, OH 43266-0149 Chairman Perry Township Board of Trustees 3750 Center Road, Box 65 Perry, OH 44081 Daniel Z. Fisher Transportation Department Public Utilities Commission 180 East Broad Street Columbus, OH 43215-3793 Joseph J. Hagan Senior Vice President of Operations and Chief Operating Officer First Energy Nuclear Operating Company Mail Stop A-GO-14 76 South Main Street Akron, OH 44308 Director, Regulatory Affairs FirstEnergy Nuclear Operating Company 395 Ghent Road Akron, OH 44333 Gary R. Leidich President and Chief Nuclear Officer FirstEnergy Nuclear Operating Company Mail Stop A-GO-19 76 South Main Street Akron, OH 44308
Perry Nuclear Power Plant, Unit 1 cc:
Danny L. Pace Senior Vice President, Fleet Engineering FirstEnergy Nuclear Operating Company Mail Stop A-GO-14 76 South Main Street Akron, OH 44308 Jeannie M. Rinckel Vice President, Fleet Oversight FirstEnergy Nuclear Operating Company Mail Stop A-GO-14 76 South Main Street Akron, OH 44308 Manager, Fleet Licensing FirstEnergy Nuclear Operating Company Mail Stop A-GHE-107 395 Ghent Road Akron, OH 44333 L. W. Pearce Vice President FirstEnergy Nuclear Operating Company Perry Nuclear Power Plant Mail Stop A-PY-A290 P.O. Box 97, 10 Center Road Perry, OH 44081-0097 Manager, Site Regulatory Compliance FirstEnergy Nuclear Operating Company Perry Nuclear Power Plant Mail Stop A-PY-A200 P.O. Box 97, 10 Center Road Perry, OH 44081-0097
Enclosure REQUEST FOR ADDITIONAL INFORMATION RELATED TO OSCILLATION POWER RANGE MONITORS PERRY NUCLEAR PLANT, UNIT 1 DOCKET NO. 50-440 In reviewing the FirstEnergy Nuclear Operating Companys (FirstEnergy) July 5, 2005, (Agencywide Documents Access and Management System Accession Number ML051940205) request to modify Technical Specification (TS) Surveillance Requirement 3.3.1.3.5, the NRC staff has determined that the following information is needed in order to complete its review:
1.
On page 1 of the cover letter, the second paragraph states that the Perry Nuclear Plant, Unit 1 (Perry) is currently operating with the oscillation power range monitors enabled at
$ 23.8-percent rated thermal power. This is below the TS value of 28.6-percent rated thermal power. Please document the historical basis for the 23.8-percent rated thermal power value.
2.
On page 4 of Attachment 2, the fourth paragraph states that General Electric developed an analytical method which can be used to explain the interactive corrective action (ICA) and enabled regions. The methodology is called backup stability protection (BSP) analysis and is used to redraw the power to flow map. The BSP analysis uses plant-specific inputs to develop decay ratios. The decay ratios are then used to adjust the ICA regions in order to provide stability protection. Please summarize the Perry-specific applicability for decay ratio.