Technical Specifications, Deletion Requirements for Submittal of Occupational Radiation and Monthly Operating Reports
ML050340152
Person / Time
Site: Duane Arnold NextEra Energy icon.png
Issue date: 01/31/2005
From: David Beaulieu
NRC/NRR/DLPM/LPD3
To: Peifer M
Nuclear Management Co
Beaulieu, David, NRR/DLPM, 415-3243
Shared Package
ML050350122 List:
References
TAC MC4620
Download: ML050340152 (2)


Text

Reporting Requirements 5.6 5.0 ADMINISTRATIVE CONTROLS 5.6 Reporting Requirements The following reports shall be submitted in accordance with 10 CFR 50.4.

5.6.1 5.6.2 DELETED Annual Radiological Environmental Ooeratina Report I

The Annual Radiological Environmental Operating Report covering the operation of the unit during the previous calendar year shall be submitted by May 15 of each year. The report shall include summaries, interpretations, and analyses of trends of the results of the Radiological Environmental Monitoring Program for the reporting period.

The material provided shall be consistent with the objectives outlined in the Offsite Dose Assessment Manual (ODAM), and in 10 CFR 50, Appendix I. Sections IV.B.2. IV.B.3, and IV.C.

The Annual Radiological Environmental Operating Report shall include the results of analyses of all radiological environmental samples and of all environmental radiation measurements taken during the period pursuant to the locations specified in the table and figures in the ODAM, as well as summarized and tabulated results of these analyses and measurements in the format of the table in Regulatory Guide 4.8. In the event that some individual results are not available for inclusion with the report, the report shall be submitted noting and explaining the reasons for the missing results. The missing data shall be submitted in a supplementary report as soon as possible.

(continued)

DAEC 5.0-19 Amendment No. 256

Reporting Requirements 5.6 5.6 Reporting Requirements (continued) 5.6.3 Radioactive Material Release Report The Radioactive Material Release Report covering the operation of the unit during the previous calendar year shall be submitted prior to May 1 of each year in accordance with 10 CFR 50.36a. The report shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste released from the unit. The material provided shall be consistent with the objectives outlined in the ODAM and Process Control Program and in conformance with 10 CFR 50.36a and 10 CFR Part 50, Appendix I, Section IV.B.1.

5.6.4 DELETED 5.6.5 CORE OPERATING LIMITS REPORT (COLR)

a. Core operating limits shall be established prior to each reload cycle, or prior to any remaining portion of a reload cycle, and shall be documented in the COLR for the following:
1.

The Average Planar Linear Heat Generation Rate (APLHGR) for Specification 3.2.1:

2.

The Minimum Critical Power Ration (MCPR) for Specification 3.2.2; and

3.

Exclusion Region in the Power/Flow Map for Specification 3.4.1.

b.

The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC in General Electric Standard Application for Reactor Fuel, NEDE-24011-P-A, (GESTAR II). The revision number is the one approved at the time the reload fuel analyses are performed.

(continued)

DAEC 5.0-20 Amendment No. 256