Category:Annual Report
MONTHYEARML0830908962008-10-28028 October 2008 Cornell University, Annual Report for the Year 2007 - June 30, 2008 ML0627200842006-08-0707 August 2006 Cornell University Environmental Compliance Office, Annual Report for Facility Licenses R-80 and R-89 ML0427404352004-09-22022 September 2004 Annual Report for the Cornell Triga Reactor ML0323104342003-08-11011 August 2003 Annual Report for Facility Licenses #R-80 and R-89 ML0233303832002-11-20020 November 2002 Annual Report for Facility Licenses R-80 & R-89, During Period of July 1, 2001 & Ending June 30, 2002 2008-10-28
[Table view] Category:Letter
MONTHYEARML14206A9892014-07-24024 July 2014 T. Smith Ltr Orau Independent Confirmatory Survey Summary and Results for the Buffalo Materials Research Center, New York ML0713603482007-06-0505 June 2007 Charles R. Fay Ltr Termination of Facility Operating License Nos. R-80 and R-89 for the Cornell University Ward Center for Nuclear Studies Reactor Facilities (TAC Nos. J00202 and J00208) IR 05000097/20060012007-04-27027 April 2007 IR 05000097-06-001 and 05000157-06-001, on 10/03/2006 - 04/25/2007; Cornell University; Ward Center for Nuclear Sciences ML0707901162007-02-28028 February 2007 Cornell University Request for Termination of Facility Operating Licenses R-80 and R-89 ML0706504092007-02-28028 February 2007 Request for Termination for Facility Licenses R-80 and R-89 ML0703703482007-02-0808 February 2007 Charles R. Fay Ltr Approval of Final Status Survey Report for the Cornell University Ward Center for Nuclear Sciences Reactor Facilities ML0702200022007-01-26026 January 2007 National Organization of Test, Research and Training Reactors(Trtr) Input on Fingerprinting Requirements for Unescorted Access to Research and Test Reactors ML0703205172007-01-19019 January 2007 Final Status Survey for the Former Ward Center for Nuclear Studies, Cornell University, NRC Docket Numbers 50-097 and 50-157 ML0712204452006-11-15015 November 2006 Letter from Orise, Report for Three Concrete and Three Soil Samples for Cornell Univ, Ithaca, New York ML0629802592006-10-26026 October 2006 Approval of Final Status Survey Plan for the Cornell University Ward Center for Nuclear Sciences Reactor Facilities ML0629800772006-10-23023 October 2006 E-mail to Research and Test Reactor from M. Mendonca Draft Directors Decision on Uncontrolled/Unmonitored Releases ML0626902182006-09-28028 September 2006 Change in NRC Staff Project Management for Cornell University Ward Center for Nuclear Science Reactor Facilities, Effective 10/01/06 ML0624404392006-08-29029 August 2006 Contact Information for Decommissioning of Cornell Research Reactor Project ML0627200842006-08-0707 August 2006 Cornell University Environmental Compliance Office, Annual Report for Facility Licenses R-80 and R-89 ML0616605482006-06-19019 June 2006 Appendix a - Facility License No. R-80 Technical Specifications for the Cornell University Triga Research Reactor ML0610304052006-06-15015 June 2006 Ward Center for Nuclear Studies at Cornell University Triga Reactor - Amendment 14 Regarding Decommissioning Plan Approval ML0610303792006-06-0606 June 2006 Letter to Dr. Charles R. Fay from Daniel E. Hughes Issuance of License Amendment No. 13 Removing Authorization to Operate and to Possess Fuel for Ward Center for Nuclear Studies at Cornell University Triga Reactor ML0609604652006-06-0606 June 2006 Cornell University, License Amendment, Removing Authorization to Possess Fuel for Ward Center for Nuclear Studies at Cornell University Zero Power Reactor, MC0212 ML0610305012006-06-0606 June 2006 Letter to Dr. Charles R. Fay from Daniel E. Hughes Ward Center for Nuclear Studies at Cornell University Zero Power Reactor-Amendment Decommissioning Plan Approval (TAC 9429) ML0534903462006-05-17017 May 2006 Ward Center for Nuclear Studies at Cornell University Research Reactor - Environmental Assessment ML0604803402006-02-13013 February 2006 Responses to Request for Additional Information (Rai), Decommissioning Plan for the Ward Center for Nuclear Studies at Cornell University, Triga Reactor ML0602705012006-02-0303 February 2006 Request for Additional Information Concerning Decommissioning Plan for the Ward Center for Nuclear Studies at Cornell University, Triga Reactor ML0603103492006-01-19019 January 2006 Technical Specifications for the Cornell University Triga Research Reactor ML0603103502006-01-19019 January 2006 Cornell University Request for License Amendment to Withdraw NRC Authorization to Receive and Posses Special Nuclear Material ML0535301292005-12-13013 December 2005 Request for Approval of the Decommissioning Plan for the Ward Center for Nuclear Studies at Cornell University and Issuance of a Decommissioning Order ML0534703262005-12-0606 December 2005 Request for a License Amendment to Withdraw NRC Authorization to Operate the Cornell Triga Reactor and to Withdraw Authorization to Receive and Possess Special Nuclear Material ML0530705462005-10-26026 October 2005 Response to Questions Dated October 26, 2005 Concerning Decommissioning Plan for the Ward Center for Nuclear Studies at Cornell University, Triga Reactor ML0527702422005-09-27027 September 2005 Response to Questions Dated September 21, 2005 Concerning Decommissioning Plan for the Ward Center for Nuclear Studies at Cornell University, Triga Reactor ML0522203422005-08-0303 August 2005 Cornell Univ Annual 10CFR50.59 Report for Facility Licenses R-080 and R-089 ML0522203432005-08-0202 August 2005 Response to EA-05-007, Issuance of Order for Additional Security Measures on the Transportation of Radioactive Material Quantities of Concern (Ramqc). ML0517803862005-05-13013 May 2005 Responses to Request for Additional Information (RAI) Concerning Decommissioning Plan for the Ward Center for Nuclear Studies at Cornell University, Triga Reactor ML0427404352004-09-22022 September 2004 Annual Report for the Cornell Triga Reactor ML0423804852004-08-18018 August 2004 Contact Information for Decommissioning of Cornell Research Reactor Project IR 05000157/20042012004-03-0303 March 2004 NRC Routine Combined Inspection Reports No. 50-97/2004-201 and No. 50-157/2004-201 ML0401505202004-01-29029 January 2004 Recission of Confirmatory Action Letter - Cornell University - Site-Specific Compensatory Measures Implementation Plan ML0403302912003-12-17017 December 2003 Cornell University Compensatory Measures Withdrawal Based on No Fuel at Research Reactor ML0327210062003-12-0505 December 2003 Confirmatory Action Letter - Cornell University - Site-Specific Compensatory Measures Implementation Plan ML0406807052003-08-26026 August 2003 Cornell University - Confirmatory Action Letter ML0324001862003-08-22022 August 2003 Request for Approval of Decommissioning Plan for Ward Center for Nuclear Studies at Cornell University & Issuance of a Decommissioning Order ML0323104342003-08-11011 August 2003 Annual Report for Facility Licenses #R-80 and R-89 ML0318202422003-06-24024 June 2003 Facility License R-80, Docket 50-157: Request for a License Amendment to Withdraw NRC Authorization to Operate Cornell Triga Reactor ML0208503322002-04-29029 April 2002 Change of Facility Project Manager Research and Test Reactors ML0209104862002-03-13013 March 2002 American Nuclear Insurers Notice of Cancellation Rescinded for Policies NF-0068, NF-0223, NW-0521 and NW-0601 2014-07-24
[Table view] |
Text
CORNELL U N I V E R S I T Y Ward Center for Nuclear Sciences Tel: (607)255-3480 Ward Laboratory, Ithaca, New York 14853 Fax: (607)255-9417 August 11, 2003 US Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555 RE: Annual Report for Facility Licenses #R-80 (Docket #50-157), and #R-89 (Docket #50-97)
Dear Sir:
The purpose of this report is to satisfy the reporting requirements of Section 50.59 of 10 CFR, Part 50, in respect to activities carried out utilizing the Cornell TRIGA Reactor (facility license R-80) and the Cornell Zero Power Reactor (ZPR) (facility license R-89) during the period beginning July 1, 2002 and ending June 30, 2003.
TRIGA License R-80:
- 1. Operating Experience On July 01, 2002 the Cornell TRIGA Reactor ceased to operate as a user facility and since that time the TRIGA has been used solely for operator requalification and for reactivity measurements, all at powers less than 10 Watts.
- 2. Changes in Facility Design None
- 3. Changes in Procedures None.
- 4. Surveillance Tests and Inspections All parameters and systems undergoing required surveillance tests and inspections were determined to be within the specified limits.
- 5. Power Generation Less than 100 Watt-hours
- 6. Emergency Shutdowns None
- 7. Unintentional Scrams None.
- 8. Major Maintenance None
- 9. Radioactive Waste Release WCNS, Cornell University 1
AotA
- 1) Liquid waste -- < 250 jCi (gross activity)
- 2) Gaseous waste - none
- 10. Personnel Exposure No significant radiation exposure to personnel was experienced.
ZPR - License No. R-89:
- 1. Operating Experience On 2/12/97, the NRC issued Amendment No. 4 which removes the authority from the license to operate the reactor and authorizes possession - only of the reactor. The ZPR fuel had been removed from the reactor grid plate prior to that date, and the reactor has been in a shutdown/safe-storage condition since that time.
- 2. Change in Facility Design None
- 3. Changes in Procedures None
- 4. Surveillance Tests and Inspections All parameters and systems undergoing surveillance tests and inspections were determined to be within the specified limits.
- 5. Major Maintenance None
- 6. Radioactive Waste Release No measurable amount
- 7. Personnel Exposure No significant radiation exposure to personnel was experienced.
On June 24, 2003 a request for license amendment to withdraw NRC authorization to operate the Cornell TRIGA Reactor. Therefore, on July 01, 2002 the Cornell TRIGA Reactor ceased to operate as a user facility and since that time the TRIGA has been used solely for operator requalification and for reactivity measurements, all at powers of less than 10 Watts.
If any additional information is required concerning this report, please don't hesitate to contact this office.
Howard C. Aderhold Director WCNS, Cornell University 2
xc: Director, Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission, Region I 475 Allendale Rd.
King of Prussia, PA 19406-1415 WCNS, Cornell University 3