Dear Mr. Robem

TABLE 1 172230003 3

10/4/2006 11:oo 3 72230004 4

10/4/2006 11:oo SAMPLE IDENTIFICATIONS AND COLLECTION DATA CORNELL UNIVERSITY ITHACA, NEW YORK

" 1722S0005 1 1722S0001 I

1 I 10/4/2006 I 11:OO I

5 10/4/2006 11:oo 1 172230002 I

2 I 10/4/2006 I

11:OO 1

1 172230006 I 6

I 10/4/2006 I 11:oo TABLE 2 CONCENTRATIONS OF SELECTED GAMMA EM1T"ING RADIONUCLIDES IN CONCRETE AND SOIL SAMPLES BY GAMMA SPECTROSCOPY CP1, REVISION 15 CORNELL UNIVERSITY ITHACA, NEW YORK Radionuclide Concentrations' @Ci/g)

CO-60 CS-137 ORISE NRC Region I Sample ID Sample ID 1722S0001 1

0.16 k 0.05b (0.05) 0.02 k 0.03 (0.03) 1722S0002 2

0.53 k 0.06 (0.05)

-0.01 2 0.02 (0.03) 1722S0003 3

0.62 k 0.05 (0.03) -0.01 f 0.01 (0.02) 1722S0004 4

0.04 f 0.04 (0.06) 0.08 k 0.03 (0.04) 1722S0005 5

0.00~ k 0.03 (0.05) 0.07 k 0.02 (0.03) 1722S0006 6

0.02 k 0.03 (0.05) 0.15 k 0.03 (0.04)

  • The MDCs are in parentheses.

bUncertainties represent the 95% confidence level, based on total propagated uncertainties.

C%ro value is due to rounding.

Comell University 1722/Letters/2006-11-14 Letter Report