Revised Dresden, Units 1, 2, and 3, 2002 Radioactive Effluent Release Report
ML032260570
Person / Time
Site: Dresden  Constellation icon.png
Issue date: 08/07/2003
From: Hovey R
Exelon Generation Co, Exelon Nuclear
To:
Document Control Desk, NRC/FSME
References
-RFPFR, FOIA/PA-2006-0130, RHLTR: #03-0055
Download: ML032260570 (47)


Text

Exe k5n.M Exelon Generation www.exeloncorp.com Nuclear Dresden Generating Station 6500 North Dresden Road Morris, IL60450-9765 Tel 815-942-2920 10 CFR 50.36a (a)(2)

August 7, 2003 RHLTR: #03-0055 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Dresden Nuclear Power Station Units 1,2, and 3 Facility Operating Licenses DPR-2, DPR-19, and DPR-25 NRC Dockets 50-10. 50-237 and 50-249

Subject:

Revised Dresden Nuclear Power Station 2002 Radioactive Effluent Release Report

Reference:

Letter from R.J. Hovey (Exelon Generation Company, LLC) to U. S. NRC, wDresden Nuclear Power Station 2002 Radioactive Effluent Release Report and Offsite Dose Calculation Manual Changes," dated April 30, 2003 The referenced letter submitted, in part, the Radioactive Effluent Release Report for January through December 2002 for Dresden Nuclear Power Station (DNPS) in accordance with Sections 6.9.A.4 and 5.6.3, "Radioactive Effluent Release Report," of the DNPS Unit 1 and Units 2 and 3 Technical Specifications, respectively and 10 CFR 50.36a(a)(2),

"Technical specifications on effluents from nuclear power reactors."

As a result of a self-assessment of the effluent monitoring program, an error was discovered in the report for the total activity reported for unmonitored liquid releases. The value for total activity was incorrectly summed. This error does not affect the calculated dose to the public and is administrative in nature. The report was completely reviewed and no other errors were found. This submittal corrects that value and resubmits the report.

Should you have any questions concerning this letter, please contact Mr. Jeff Hansen, Regulatory Assurance Manager, at (815) 416-2800.

August 7, 2003 U. S. Nuclear Regulatory Commission Page 2 Respectfully, R. J. oe Site Vice President Dresden Nuclear Power Station Attachments: DNPS 2002 Radioactive Effluent Release Report (Revision 01) cc: Regional Administrator - NRC Region Ill NRC Senior Resident - Dresden Nuclear Power Station

Revision 01 - August, 2003 DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 DOCKET NUMBERS: 50-010/50-237/50-249 Regulatory Limits

a. For Noble Gases Ln tRate
1) Less than 500 mrem/year to the whole body.
2) Less than 3000 mrem/year to the skin.
1) Less than or equal to 5 mradlquarter.
2) Less than or equal to 10 mrad/year.

Beta Rafdintin I) Less than or equal to 10 mrad/quarter.

2) Less than or equal to 20 mrad/year.

b.,c. For lodine-131, for lodine-133, and for all radionuclides in particulate form with half-lives greater than 8 days.

rOna Rate

1) Less than 1500 mrem/year, Dose
1) Less than or equal to 7.5 mrem/quarter to any organ.
2) Less than or equal to 15 mrem/year to any organ.
d. For Liquid
1) Less than or equal to 1.5 mrem to the whole body during any calendar quarter.
2) Less than or equal to 5 mrem to any organ during any calendar quarter.
3) Less than or equal to 3 mrem to the whole body during any calendar year.
4) Less than or equal to 10 mrem to any organ during any calendar year.
2. Maximum Permissible Concentration a., b., c. For fission and activation gases, iodines and particulates with half-lives greater than 8 days, allowable dose rates are calculated by solving equations 10.1 and 10.2 from the Offsite Dose Calculation Manual.
d. For liquid effluents, allowable release limits are calculated by solving equations 10.3 and 10.4 from the Offsite Dose Calculation Manual.
3. Average Energy The average energy of fission and activation gases was calculated for the gaseous effluents released from the site.

The average energy is based on the percentage of each fission gas nuclide present and its average energy per disintegration (E in MeV/dis) for gamma and beta emissions separately.

EaAMMA 6.39E-01 MeV/dis EBETA = 4.37E-01 MeV/dis I

Revision 01 - August, 2003 I DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 t)OCKET NUMBERS: 50-010/50-237/50-249

4. Measurement and Approximations of Total Radioactivity
a. Fission and Activation Gases:
b. lodines:

C. Particulates:

The Units 2/3 and Unit I Chimneys, Units 2/3 Reactor Building Vent and Unit I Chemical Cleaning Building effluents are continually sampled for iodines and particulates. These samples are pulled weekly and analyzed by gamma isotopic. The particulate filters are composited and sent to a vendor for gross alpha, Sr-89/90 and Fe-55 analysis. Noble gas grab samples are pulled and analyzed by gamma isotopic weekly. Tritium samples are pulled and analyzed monthly.

For the Units 2/3 Chimney and Units 2/3 Reactor Building Vent effluents, the average flow at the release points is used to calculate the Curies released. For the Unit 1 Chimney and Unit 1 Chemical Cleaning Building effluents, the design basis flows are used to calculate Curies released.

d. Liquid Effluents:

The river discharge tanks are analyzed by isotopic prior to discharge. A representative portion of this sample is saved and composited with other discharges that occur during the sampling period. The composite is sent to a vendor for analyses of gross alpha, H-3, Fe-55, Sr-89/90 content.

The tank volumes and activities are used to calculate the diluted activity released at the discharge point from batch discharges.

e. Less than the lower limit of detection (<LLD)

Samples are analyzed such that the ODCM LLD requirements are met. When a nuclide is not detected then <LLD is reported.

f. Equipment out-of-service None.
g. Estimation of Data/Corrections:

(1) On May 13, 2002, an isotopic analysis of a weekly iodine sample pulled from the Unit 1 Chemical Cleaning Building release point identified several radionuclides that are not typical for this sample location. The condition was identified on June 12, 2002 (Reference Dresden Station Condition Report #112461). Reanalysis of the sample at that time confirmed normal results without the additional radionuclides, however, due to the time period between the sampling and the re-count, the required lower-limit-of-detection (LLD) for lodine-133 could not be demonstrated for the re-count. Iodine-133 is not normally found in the Unit I Chemical Cleaning Building effluents, and as such is estimated as zero for the May 6, 2002 to May 13, 2002 sampling period.

(2) On August 7, 2002, the weekly iodine and particulates samples pulled from the Unit I Chimney release point were not analyzed for isotopic activity. The condition was identified on August 19, 2002 (Reference Dresden Station Condition Report #119830). The samples were subsequently analyzed, however, due to the time period between the sampling and the analysis, the required lower-limit-of-detection (LLD) for Iodine-133 could not be demonstrated. Iodine-1 33 is not normally found in the Unit I Chimney effluents, and as such is estimated as zero for the July 31, 2002 to August 7, 2002 sampling period.

2

Revision 01 - August, 2003 I DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 DOCKETNUMBERS: 50-010/50-237/50-249 SUMMATION OF ALL GASEOUS RELEASES 3rd 4th Est. Total 1nits: lot 2ar Frrar 0/n Olirtnr Qu1afrr A. FISSION & ACTIVATION GASES

1. Total Release Ci 5.19E+01 4.64E+L . 5.21E+01 2.67E+01 7.31%
2. Average Release Rate for the Period 4Ci/sec 6.67E+00 5.91E+00 6.56E+00 3.36EF+00
3. Percent of Technical Specification Limit  %

B. IODINES

1. Total Iodine-131 Ci 7,69E-04 9,33EA04 9 L 193E L1I3E-03 21.6%
2. AverageReleaseRateofl-131 forthe Period-.--C/sec 9.89E1-05 1A19E-04 1,25E 04 .143E 04
3. Percent of Technical Specification Limit  %
4. Totallodine-131. lodine-133 and lodine-135 Ci 24.8E-03 6,29E-03 3.76E-03 9.61E-03 C. PARTICULATES
1. Particulates with half-lives > 8 days Ci 1.IOE-02 2d13E-03 2A.E-03 2.16E-03 34.1%
2. Average Release Rate for the Period i/sec 1.41E-03 2.70E-4 301E-04 2272E-04
3. Percent of Technical Specification Limit  %°. * , * *
4. Gross Alpha Radioactivity Ci 1AOE-05 1.14E-05 1J04E-05 1L37E-05 D. TRITIUM
1. Total Release l l.51E+01 4.82E+01 l2.68E+01 1.90E+01 l 7.89%
2. Average Release Rate for the Period I maC1tat'-

4 -"----

T I

1 Q95E+Ot) 4 13EI+00 I

+

3 %RF4+0 II 2)39Q+0() -

= 3 Percent of Technical Snecification Limit I 0/, I

  • i
  • I * -I
  • I L ______________ .1
  • The information is contained in the Radiological Impact on Man section of the report. Total airborne release data are provided which include fission and activation gases, iodines, particulates, tritium.

3

Revision 01 - August, 2003 I DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 DOCKETNUMBERS: 50-010/50-237/50-249 TABLE OF LOWER LIMITS OF DETECTABILITY FOR AIRBORNE EFFLUENTS

1. FISSION/ACTIVATION GASES jiCi/ml Kr-87 I .00E-06 Kr-88 1.00E-06 Xe-133 1.00E-06 Xe-133m 1.00E-06 Xe-135 1.00E-06 Xe-138 1.00E-06
2. IODINES 11Ci/ml I-131 1.00E-12 I-133 1.OOE-10
3. PARTICULATES jICi/il Sr-89 1.00E-l 1 Sr-90 1.OOE-l l Mn-54 1.00E-1 I Fe-59 1.OOE-I 1 Co-58 1.00E-l I Co-60 1.00E-1 I Zn-65 1.00E- I1 Mo-99 l .OOE-l I Cs-134 1.00E-I I Cs-137 1.00E-l 1 Ce-141 1.001E-l 1 Ce-144 1.OOE-l 1
4. OTHER 1 +/-Ci/ml H-3 1.OOE-06 Gross Alpha 1.00E-I 1 The above values are the ODCM-required LLDs. Except for the conditions noted in Section 4.g. of this report, the actual analyses always met the required LLDs.

4

Revision 01 - August, 2003 I DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 DI MAIN CHIMNEY GASEOUS EFFLUENTS DOCKETNUMBERS: 50-010 GROUND LEVEL RELEASES SEMI-ELEVATED RELEASES YY ELEVATED RELEASES CONTINtOUS MODE NUCLIDES RELEASED UNIT I' QTR 2" QTR 3w QTR l 4 QTR TOTAL FISSION GASES Ar-41 _ ___

_CiI I___I * *

  • a l 4.81E+00 Kr-87m Ci Kr-87 Ci * * *
  • Kr-88 .C....**

Xe-133 Ci * * * *

  • Xe-133m Ci _ .

Xe-135 Ci . S

  • S
  • Xe-135m Ci Xe-138 Ci _ S * *
  • TOTAL Ci 4.81 E+00 None None None 4.81 E+00 IODINES 1-131 Ci  : -

1-133 Ci *a 1-135 Ci a a TOTAL Ci None None None None None PARTICULATES Fe-55 Ci a a a Sr-89 SL. a a Sr-90 Ci

  • a Be-7 CL.... aa Cr-51 Ci . a a a a Mn-54 Ci 5.1I E-07 5.55E-07 9.49E-07 1.07E-06 3.09E-06 Co-57 Ci a Co-59 .... L.... a Fe-59 Ci a a a Co-60 Ci 2.74E-07 7.88E-07 8.75E-07 1.I3E-06 3.07E-06 Zn-65 ......C...

Sr-85 Ci a Za-95 Ci

Ru-103 Ci*

  • a 6.01E-06 AL-)lOOm Ci a a a a a Sn-I13 Ci a Sb-124 Ci* a a Sb-125 Ci a a a Cs-134 Ci a a a Cs-136 Ci a a a Cs-137 Ci a a a Ba-133 Ci 4.76E-07 a 4.76E-07 Ba-140 Ci a a a a Ce-141 Ci *
  • a a a Ce-144 Ci a- a TOTAL Ci 1.26E-06 7.35E-06 1.82E-06 2.20E-06 1.26E-05
  • The activity of this nuclide is less than the LLD. " LLD for 1-133 not met (see Section 4.g.). Result estimated as zero.

5

Revision 01 - August, 2003 I DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 DI MAIN CHIMNEY GASEOUS EFFLUENTS DOCKET NUMBERS: 50-010 GROUND LEVEL RELEASES SEMI-ELEVATED RELEASES xx ELEVATED RELEASES BATCH MODE NUCLIDES RELEASED UNIT I1QTR 2" QTR 3i QTR 46 QTR TOTAL FISSION GASES Ar-41 Ci Kr-85 Ci I Kr-85m Ci . ._.

Kr-87 Ci .

Kr Ci Xe-133 Ci Xe-133m Ci Xe-135 Ci  : _

Xe-135m Ci Xe-138 Ci ._ .

TOTAL Ci None None None None None 1ODINES 1-13 1 __ _ _ _ _ _ _ _ _ _ __ _ _ __ _ _ _ _ _ _ _

1-133 C_

1-135 - Ci TOTAL Ci. None None None None None PARTICULATES Fe-55 Ci Sr-89 Ci S r-90 __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Be-7 _C_

Cr-51 Ci . .

Mn-54 Ci Co-57 Ci CO-58 S L _ _ __ _ __ _ _ _ _ _

Fe-59 Ci Co-60 Ci_

Zn-65 Ci Sr-85 Ci _

Zr-95 C_

Mo-99 Ci I Ru-103 :_Ci AQ-110mrC Sn-113 Ci .

Sb-124 Ci Sb-125 _ _ _ _ _ _ _

Cs-1 34 Ci Cs-136 Ci Cs-137 Ci .

Ba-133 Ci Ba-140 Ci Ce-141 Ci Ce-144 Ci .

TOTAL Ci None None None None None

  • The activity of this nuclide is less than the LLD.

6

Revision 01 - August, 2003 I DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 D213 REACTOR BULDING VENT GASEOUS EFFLUENTS DOCKET NUMBERS: 50-237/50-249 GROUND LEVEL RELEASES Yy SEMI-ELEVATED RELEASES ELEVATED RELEASES CONT NUO S M ODE__

NUJCLIDES RELEASED UNIT 1' QTR 2" QTR 3"QTR e' QTR TOTAL FISSION GASES Ar-41 S *S Kr-85 *i 1.05E-04 IOSE-04 L

Kr-85m Ci 1.03E-04 I03E-04 1

Kr-87 .C..*

Kr-88 * *S Xe-133m

  • 8.04E-05* 8.04E-05 Xe-133 Cj S.96E-01 4,82E-06 1.14E-05 8.96E-01 Xe-135 SL... 2.29E-05 *5.31 E-06 1.19E-04 JAZ7E-0 Xe-I135m .C.... *S75E-05 5, 5,75E-05 Xe-138 * *S TOTAL Ci S.96E-01 2.88E-04 1.OIE-05 1.88E-04 8.97E-01 IODINES 1-131 Ci 4,25E-05 6,28E-05 1,23E-04 1.43E-04 37E-0 1-133 Ci 1.37E-04 1,92E-04 5.20E-04 3.72E-04 1.22 -3 1-135 .. CLi.. 6.II1E-04 6.1 1E-04 TOTAL Ci 1.SOE-04 2.55E-04 6.43E-04 1.13E-03 2.20E-03 PARTICULATES Fe-55 Qi 4,34E-03 4.9E-05 2.33E-05 8.53E-05 4.50E-03 Sr-89 Ci 5.91E-06 1.54E-06 6,62E-07 *81E0 So o9 .CL... 2,47E-07 _ _ _ _ _ _ _ _524 E0 Be-?
  • 3.43E-04 Mn-54 Ci 2.39E-03 1.94E-04 1.19E-04 2.27E-04 2.93E-03 Co-57 .CL..
  • Nb-95 i
  • Mo-9 CiL.... 2.15E-05 *2.15E-05 Ru-103 SL...
  • I .98E-O5 7.84E-06 *2.77E-05 At-I 1Om .. CL.... 3,32E-05 3.49E-06 3,66E-03 Sn-1 13 Ci **

Sn- I 17m Ci 3.56E-06 *5 3,56E-06 Sb-1 24 CL 8.09E-05

  • I1.48E-05 3.96E-06 1.7-5 Ba-133 *

Ce-144 5*

Hiz-203 Ci *S TOTAL Ci 9.72E-03 6.13E-04 2.33E-04 6.08E-04 1.12E-02

  • The activity of this nuclide is less than the LLD.

7

Revision 01 - August, 2003 I DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 D2/3 REACTOR BUILDING' VENT GASEOUS EFFLUENTS DOCKET NIJMBERS: 50-237/50-249 GROUND LEVEL RELEASES yY SEMI-ELEVATED RELEASES ELEVATED RELEASES ATCH MODE NUCLIDES RELEASED UNIT il QTR T 2 QTR 3' QTR 4" QTR TOTAL FISSION GASES Ar-41 Ci_l _

Kr-85 Ci_._.

Kr-85m Ci ._.

Kr-87 Ci Kr-88 Ci Xe-133 Ci Xe-133m Ci Xe-135 Ci Xe-135rn __ __ __ _

Xe-138 Ci _

TOTAL Ci None None None None None IODINES 1 -1 3 1 __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

1-133 ai __ _ _ __ _ _

1-135 - Ci TOTAL Ci None None None None None PARTICULATES F e - 5S5 __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _

Sr-89 __ __ __ _ _

Sr-90 Ci Be-7 Ci C r -5 1 __ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _

Mn-54 Ci Co-57 Ci .

Co-58 Ci F e-5 9 __ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _

C o -6 0 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Z n -65 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Sr-85 Ci _ _

Zr-95 Ci _ . _

Mo-99 Ci .

Ru-1 0 3 Ci _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

A e-I 1O m Ci _ _ _ _ _ __ _ _ _ _

S n-I 1 3 __ _ _ _ _ _ __ _ _ _ _ _ _ __ _ _ _ _ _ _

Sb-124 Ci _ _ _ _

Sb-125 Ci Cs-134 Ci Cs-136 (i _ _ _ _ _ _

Cs-137 C _

Ba-133 Ci B-140 Ci . .

C e-14 1 __ _ _ _ _ _ __ _ _ _ _ _ _ __ _ _ _ _ _ _

Ce-144 ICi TOTAL Ci None None None None None

  • The activity of this nuclide is less than the LLD.

8

Revision 01 - August, 2003 I DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 D2/3 MAIN CHIMNEY GASEOUS EFFLUENTS DOCKETNUMBERS: 50-237/50-249 GROUND LEVEL RELEASES SENH-ELEVATED RELEASES xx ELEVATED RELEASES -

CQNTNUOS MODE _ _ _ _ _ _ _ _ _ _

NUCLIDES RELEASED UNIT 1 QTR 2"wQTR 3" QTR 4* QTR TOTAL.

FISSION GASES Ar-41 CL 4.23E-0I 1.30E-01 3,231E-01 1.16E-01 -- 9.93-E-01 K~r-85 * **

Kr-85m Li 4.68E-01 1.81E+00 1.58E+00 9.09E-01 4.77E+00 Kr-87 ai 1,83E+00 9,61E-01 -- 118E+00_ 9,70E3-01 4.94E+00 Kr-88 co 8.12E-01 9,45E-01 1,711E+00 1.62EO 5.08E+00 Xc-131m __ _ _ __ _ _ _

Xe-133 CL 8.68E-01 7.48E-01 2,86E+00 9.651E-01 5.44E+00 Xe-133m ... C6... 4,5313-01 4.OO1-02 4,9313-01 Xc-135 jCL 2.06E+01 1.30E+01 1.69E+01 9.13E+00 5.96E+01 Xe-135m ..S.... 8,28E+00 4.1 1E+00 4.7 EOO2.8EOOI98BE+01 Xe-138 CL 1,24E+01 2,4813+01 2,2813+01 1.03E+01 7.02E+01 TOTAL Ci 4.62E+01 4.64E+01 5.21E+01 2.67E+01 1.71E+02 IODINES 1-131 .. i 7,27E-04 8,70E-04 9.9913-04 9,911E-04 3.59E-03 1-133 SL.. 1.34E-03 I.-97M-3 1.97E-03 -2.04E-03 7,33E-03 1-135 .. L.. 2.29E-04 3-19E-03 1.49E-04 5,45E-03 9,01E-03 TOTAL Ci 2.3013-03 6.0313-03 3.1213-03 8.48E-03 1.99E-02 PARTICULATES Fe-55 CL 4.4313-05 *2,77E-05 6.43E-05 1.36E-04 Be-7

  • S*

Cr-51 * **

Mn-54 ..... L.. 2.13E-04 2.07E-04 2.44E-04 - .5-49.09E-04 Co-S7 * **

Co-58 Cj 2.OOE-06 *1. IOE-05 1,30E3-05 Fe-59 * **

Co-60 .C.... I1.9313-04 I1.06E-04 2,96E-04 3.47E-04 9,42E-04 Zp-65 SL 8...15LEQ-06... 6,28E-06 1.82E-05 3.26E3-05 Sr-85

  • S*

Y-88 C **

Sr-89 SL 1 95E-04 3,37E-04 2.34E-04 2.20E-04 9,86E-04 Sr-90 SL 1,9213-06 1.92E-06 Zr-95 ...... L..*S.

MO-99 * **

Ru-103 * **

Cd-109 * **

A2~-1 IlOmn ~ 2,911E-05 *3.41 E-05 *6.33E-05 Sn-I 13 ... S... 3,8513-06 ** 3,8513-06 Sn-I 17m * **

Cs-136 0 *5.41 E-06 5 .41 E-06 CS-137 *

Cc-14

  • 8.02E-06 *8.02E-06 Ce-144 6 5 3.14E-05 *3.1413-05 TOTAL Ci 1.191E-03 1.50E-03 2. 16E3-03 I1.46E3-03 6.31IE-03
  • The activity of this nuclide is less than the LLD.

9

Revision 01-August, 2003 I DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002:

D2/3 MAIN CHIMNEY GASEOUS EFFLUENTS DOCKET NUMBERS: 50-237/50-249 GROtJND LEVEL RELEASES SEMI-ELEVATED RELEASES XX ELEVATED RELEASES 3ATCH MODE NUCLIDES RELEASED UNIT I QTR 2f QTR 3V QTR 4 QTR TOTAL FISSION GASES Ar-41 Ci Kr-85 Ci Kr-85mi Kr-87 Ci K~r-88 Xe-133 . Ci Xe-133m C Xe-135 Ci_.

Xe-135m Ci Xe-138 Ci TOTAL Ci None None None None None MODINES 1-131 __ _ _ __ _ _ _

1-133 Ci 1-135 Ci  :

TOTAL Ci None None None None None PARTICULATES Fe-55 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Sr-89 Ci Sr-90 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Be-7 Ci .

Cr-51 Ci _ _ _ _ _ _ _ __ _ _ _ _ _ _ _

Mn-54 Ci .

Co-57 Ci .

Co-58 Ci Fe-59 __ _ _ _ __ _ _ __ _ _ _ _

Co-60 ci Zn-65 Ci _ _ _ _ _ __ _ _ _ _ _

Sr-85 __

Zr-95 Ci .

M o-99 _ _ _ _ _ __ _ _ _ _

Ru-103 Ci .

A2-110m Ci Sn-113 Ci Sb-124 Ci .

Sb-125 Ci _ _ _ _ _ _ __ _ _ _ _ _ _

Cs-134 Ci Cs-136 - Ci_ .

Cs-1373 Ci Ba-133 __ _ _ _ _ __ _ _ _ __ _ _ _ _

- Ba-140 Ci .

Ce-141 Ci Ce-144 Ci TOTAL Ci None None None None None

  • The activity of this nuclide is less than the LLD.

10

Revision 01 - August, 2003 I DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 CHEMICAL CLEANING BUILDING GASEOUS EFFLUENTS DOCKET NUMBERS: 50-010/50-237/50-249 GROUND LEVEL RELEASES xx SEMI-ELEVATED RELEASES ELEVATED RELEASES CONTINUOUS MODE NUCLIDES RELEASED UNIT l 1 QTR 2' QTR 3* QTR 4i QTR TOTAL FISSION GASES Ar-41 Ci Kr-85 Ci* * *

  • Kr-Sm Ci
  • Kr-87 Ci * * * *
  • Kr-88 Ci
  • S *
  • S Xe-133 Ci *
  • Xe-133m Ci * *
  • Xe-135 Ci* * *
  • Xe-135Sm *
  • Xe-138 Ci* *
  • TOTAL Ci None None None None None IODINES 1-131 .. Ci * * * *
  • 1-133 Ci (2) 1-135S * * - *
  • TOTAL Ci None None None None None PARTICULATES Fe-55 C
  • S *
  • Sr-89 Ci
  • S S *
  • Be-7 - Ci * * *
  • Cr-5 I Ci S Mn-54 Ci 2.OOE-06 3.44E-07 9.23E-07 1.62E-06 4.89E-06 Co-57 Ci . . *
  • Co-58 Ci
  • Fe-59 Ci * *
  • Co-60 Ci 2.78E-06 9.99E-07 7173E-07 5.83E-07 5.14E-06 Zn-65 Ci * * * *
  • S a Ru-103 Ci
  • Aa-110m Ci *
  • S . S Sn-113 Ci*
  • Sb-124 Ci i
  • S _

Sb-125 Ci * * * *

  • Cs-134 Ci
  • S * .
  • Cs-136 Ci * * *
  • Ba-133 Ci- * *
  • Ba-140 Ci * * * *
  • Ce-141 Ci* * * *
  • Ce-144 Ci *
  • TOTAL Ci 4.78E-06 1.34E-06 1.70E-06 2.21&E06 1.OOE-05
  • The activity of this nuclide is less than the LLD. (2 LLD for 1-133 not met (see Section 4.g.). Result estimated as zero.

11

Revision 01- August, 2003 I DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 CHEM1CAL CLEANING BUILDING GASEOUS EFFLUENTS DOCKET NUMBERS: 50-010/50-237/50-249 GROUND LEVEL RELEASES xx SEMI-ELEVATED RELEASES ELEVATED RELEASES 3ATCX MODE NUCLIDES RELEASED UNIT I7 QTR 2' QTR 3" QTR 4' QTR TOTAL FISSION GASES Ar-41 Tci_7_-_I1 K r-85 __ _ _ __ _ _ __ _ ___I__ _ _

Kr-85m Ci Kr-87 Ci Kr-88 C _

X e-133 __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Xe-133m - Ci Xe-135 __ _ _ __ _ _ _

Xe-; 35m Ci _

Xe-138 Ci TOTAL Ci None None None None None IODINES 1-131 Ci  :

1-133 Ci _ ___

1-135 _ _ _ _ _ _ _ _

TOTAL Ci None None None None None PARTICULATES Fe-55 __ _ _ _ __ __ _ __ _ _ _

Sr-89 _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _

Sr-90 Ci Be-7 Ci .

Cr-51 Ci _ .

Mn-54 Ci C o-57 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Co-58 Ci_:

Fe-59 Ci Co-60 _ _ _ _ _ _ _ _ _ _ _ _ _ _

Zn-65 Ci _

Sr-85 __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

zr-95 __ _ _ __ _ _ __ _ _ _

MO-99 Ci Ru-103 Ci Aiz-1 lOm Ci Sn-113 Ci Sb-124 a Sb-125 __ _ __ _ __ _

Cs-134 °___-

Cs-I136 __ _ _ __ _ _

Cs-137 Ci Ba-133 Ci Ba-140 Ci Ce-141 Ci . _ _ _ _

C e-144 _ _ _ _ _ _ __ __ _ _

TOTAL Ci None None None None None The activity of this nuclide is less than the LLD.

12

Revision 01 - August, 2003 I DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AN4D 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 DOCKETNUMBERS: 50-010/50-237/50-249 TABLE OF LOWER LIMITS OF DETECTABILITY FOR LIQUID EFFLUENTS

1. FISSION/ACTIVATION GASES jICi/mi Kr-87 1L.OE-05 Kr-88 I .OO-05 Xe-133 1.OE-05 Xe-133m 1.OO-05 Xe-135 1.OOE-05 Xe-138 1.01E-05
2. IODINES gaC/ml 1-131 1.001E-06
3. PARTICULATES 1x&i/ml Fe-55 I .OOE-06 Sr-89 5.OOE-08 Sr-90 5.OOE-08 Mn-54 5.OOE-07 Fe-59 5.00E-07 Co-58 5.OOE-07 Co-60 5.OOE-07 Zn-65 5.OOE-07 Mo-99 5.OOE-07 Cs-134 5.OOE-07 Cs-137 5.O01E-07 Ce-141 5.OOE-07.

Ce-144 5.OOE-06

4. OTHER ACi/ml H-3 1.00E-05 Gross Alpha 1.001E-07 The above values are the ODCM-required LLDs. Actual analyses always met the required LLDs.
  • The ODCM-requiredLLDfor Ce-144 was revisedfrom 5.00E-07,uCi/ml to S.OOE-06 .Ci/ml in December of 2002.

Analyses performedpriorto December 2002 were subject to the more restritiverequirement.

13

Revision 01 - August, 2003 I DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 DOCKETNUMBERS: 50-010/50-237/50-249 SUMMATION OF ALL LIQUID RELEASES 3f8 4th Est.

Quas01frte, Qu3arter Qulartpr 01Qarr Total FP.rrnr e/.

A. FISSION & ACTIVATION PRODUCTS

1. Total Release (not including H-3. gases. alpha) Ci 4A22E-04 .2&04E-03 2.17E-02 3.06E-03 10.6%
2. Average Diluted Conc. During Period 4 3&ihnl 77E-09 3.56E-08 2.22E-0 4 JAIEQL
3. Percent of Technical Specification Limit  % * * *
  • B. TRrTIUM _______ _______ - 4
1. Total Release l Ci - l 1.05E+01 Q 5.76E+00 1.440E+01 11.13E+01 11.4%
2. Average Diluted Conc. During Release KjiCi/ml 9.37E-05 1.00E-04 7.55E-05 5.24E-05
3. Percent of Technical Specification Limit  % * * *
  • C. DISSOLVED AND ENTRAINED GASES
1. Total Release V - Ci <LLD <LLD <LLD <LL .58%
2. Average Diluted Conc. During Period .Ci/ml <LLD { <LLD <LLD 4 <LLD
3. Percent of Technical Specification Limit  % * * *
  • D. GROSS ALPHA ACTIVITY
1. Total Release l Ci l <LLD 1.20E-05 7.26E-05 4.01E-05 15.1%

(prior to dilution! l Liters 1.33E+06 l 8.35E+06 l 4.91E+06 l 1.63E+06 l 5.W/

F. VOLUMEOFDILUTIONWATERUSED l Liters 1.1 1E+08 5.67E+07 9.76E+08 2.15E+08 5.00% l

  • The information is contained in the Radiological Impact on Man section of the report.

14

Revision 01 - August, 2003 I DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 RADWASTE LIQUID EFFLUENTS DOCKETNUMBERS: 50-010/50-237/50-249

1. Number of Batch Releases: 23
2. Total Time for Batch Releases: 8.79E+03 minutes
3. Maximum Time Period for a Batch Release: 8.87E+02 minutes
4. Average Time Period for a Batch Release: 3.82E+02 minutes
5. Minimum Time Period for a Batch Release: 3.32E+02 minutes
6. Average Stream Flow During Periods of Release of Effluent into a Flowing Stream: 1.51E+05 Ipm RATC'1 MOM)fl UInit 1" Ouanrttr 9 d Ouarter 3 Ouiiarter 41h Oairter Tntal Fe-55 Ci 9.26E-05
  • 1.09E-02
  • 1.1 OE-02 Sr-89 C * * * *
  • 1-131 Ci 1-132 Ci . -

I-133 Ci * * * *

  • 1-134 Ci *
  • 1-135 Ci * * * *
  • C-51 Ci
  • 9.31 E-05 9.75E-05 1.91E-04 Mn-54 Ci 9.89E-05 3.62E-05 2.45E-03 3.56E-04 2.94E-03 Co-58 Ci *
  • 2.71E-05 3.24E-05 5.95E-05 Fe-59 *
  • 156-04 5.42E-05 2.1OE-04 Co-60 Ci 1.54E-04 4.29E-05 5.49E-03 6.80E-04 6.37E-03 Zn-65 *
  • 1.72E-04 7.93E-04 9.66E-04 As-6 Ci * * *
  • Zr-95 Ci *
  • Sr-91 Ci Mo-99 C* 8.65E-05
  • cu-1m Ci AgI-10m CiL 7.72E-05 1.27E-05 5.01E-04 2.08E-04 7.99E-04 Sb-124 Ci
  • i Cs- 134 - Ci** **

Csj 136 Ci 1.49E-05 1.49E-05 Cs-137 Ci

  • 1.81 E-05 1.811E-03 9.38E-05 1.93E-03 Cs138 C La-140 Ci
  • Ce-141 Ci
  • i 1.55E-05
  • 1.55E-05 (above) Ci 4.22E-04 1.IOE-04 2.17E-02 2.31 E-03 2A6E-02 To ta l_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Tt1L . Ci 1.05E+01 5.76E+00 7.40E+01 1.1 3E+01 1.02E+02 Kr-87 Ci * * *- *s Kr-88 Ci Xe-133 Ci i *i *

  • Xe-133m Ci * * * *
  • Xe-135 Ci
  • i
  • i is Xe-138 Ci *
  • The activity of this nuclide is less than the LLD.

15

Revision 01 - August, 2003 1 DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 RADWASTE LIQUID EFFLUENTS DOCKETNUMBERS: 50-010/50-237/50-249 flONTlM lOtIT MOMF I In,* is, nnbarter 2V frivarter 'A3()lharfpr 4'h Ouatter Tntal Fe-55 7 ci II  : 711 Sr-89 Ci-Sr-90 Ci .

1-131 Ci _ _

1-132 Ci _

1-133 1-134 Ci_

Ci Cr-51 Ci Mn-54 Ci__

Co-S8 Ci Fe-59 Ci _

Co-60 Ci Zn-65 Ci _

As-76 Ci _

Zr-95 Ci  :

Sr-91 Ci.

Mo-99 Ci .:

Tc-99m Ci R-103 Ci Ag-110m Ci SS124 Ci Cs-136 Ci...

.Cs-137 Ci Cs-138 Ci.

Total Ci None None None None -None H-3 Ci..

Kir-87 Ci Kr-88 Ci..

Xe-133 Ci Xe-133m ICiI Xe-135 Ci.

Xe-138 Ci

  • The activity of this nuclide is less than the LLD.

16

Revision 01 - August, 2003 I DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 LPCI SysTEM EFFLUENTS DOCKET NUMBERS: 50-237/50-249

1. Number of Batch Releases: 143
2. Total Time for Batch Releases: 1.77E+02minutes
3. Maximum Time Period for a Batch Release: 1.24E+00 minutes
4. Average Time Period for a Batch Release: 1.24E+00 minutes S. Minimum Time Period for a Batch Release: 1.24E+00 minutes
6. Average Stream Flow During Periods of Release of Effluent into a Flowing Stream: 9A6E+04 Ipm

-I RATf' Mr Fllp 4Ah nnarth.r Tntal Fe-55 Ci 7 t I * *

  • I

. .Sr-89 Ci -.___ ___t . *

  • Sr-90 Ci . 8.20E-06 9.12E-07
  • 9.11E-06 1-131 Ci .

1-132 - . *Ci

  • 1-3 Ci ., * . *
  • 1-134. Ci tk T-135;Ci. *
  • Cr-51 Ci * * - *
  • 1.44E-05 *
  • 1.44E-05 Co-58 Ci * * *
  • Fe-59 Ci.

Co-60 .Ci 1.67E-05

  • 2.51 E-06 1.92E-05 Zn-65 . Ci 3, 44E 3.44E-06 As-76 Ci* * * * *

-S9  : Ci . *

  • Sr Ci * *
  • Tc-99m Ci*

Ru-103 Cij * * *

.Agl1m. . ~*C * -

Sb-124 Ci * * * *

  • Cs-134 Ci Cs-136 . CiL  : * * . *
  • Cs-137 I.. Ci 6.47E-06 5.32E-06 1.74E-05 8.49E-07 3.OOE-05 Cs-138 Ci * * * *
  • Ba-140 Ci * * * *
  • La-140 Ci Ce-141 Ci * -

NP-239 Ci

  • 3.92E-06 *
  • 3.92E-06 (above) Ci 6.47E-06 4.81E-05 1.83E-05 3.36E-06 7.62E-05 T o t al_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
H-3 lCi .

TKr-87 Ci * * * *

  • Kr-88 Ci * * *
  • Xe-t33 Ci * * *l lb Xe-135 Ci * * . * - ,,

Xe-138 Ci

  • lb
  • The activity of this nuclide is less than the LLD.

17

Revision 01 - August, 2003 I DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 LPCI SYSTEM EFFLUENTS DocKETNuMBERS: 50-237/50-249 lnsn' inaI 1(r1 T9 MopA 1 li.; Ia" lhartpr ?rA "nrte-r I'd Oiiartpr 44 "livrti-r Total Fe-55 Ci Sr-89 Ci ..

Sr;90 Ci _

1-132 1-131 Ci _ ==

1r-1334 Ci.

1-135 Ci Co-58 Ci .

As-76 Ci u-103 Mn- 954 Ci.

Ci ZnS-1 Mo-99 Ci Ci .-

Tc-599 Ci Cs-134 Ci: -

Ccsl396 Ci a-140m Ci _

Cs-138 Ci .

La-140 Cs-137 Ci.

Ci

.~flL.

Ci__________

BaKr-NCs2136 Ci._

Ci Ce-141 .. L. _ _ _ __ __ _ _ _ _ _

N rn-239 Ci _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

None None None None La-14(above) CiCi To tal _ =None H-3 C L_ __

Kr88 Ci _ ____

X e-138 I Ci _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

  • The activity of this nuclide is less than the LLD.

18

Revision 01 - August, 2003 1 DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2602 DOCKET NUMBERS: 50-010/50-237/50-249 UNITS 1, 2 & 3 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL NOQ IRRADIATED F LJEL 12-month

1. Type of Waste Unit nerod Est. Total Error, %
a. Spent resins, filter sludges, evaporator bottoms, etc. m' 1.19E+02+/-25° Ci 1.6213+03 +/-25O
b. Dry compressible waste, contaminated equipment, etc. Ci 2.8E+03 1 +/- 25%

Ci 4.40E+01 +/- 25%

c. Irradiated components, control rods, etc. .nL 164E+00 Ci 1.75E+04+/-25
d. Other (describe) - Contaminated Soil .m 2.47E+02 +/-

Contaminated Oil . .Ci 1.82E-01 i 25%

2. Estimate of Major Nuclide Composition (by type of waste)
a. Spent resins, filter sludges, evaporator bottoms, etc.

Perrent 0/%

Fe-55 59.51% 9.64E+02 Co-60 23.47% 3.80E+02 Cs-137 7.27% 1.18E+02 Mn-54 4.99% 8.09E+01 Zn-65 1.92% 3.1 IE+01 Ni-63 1.12% 1.81E+01 C-14 1.35% 2.19E+01

b. Dry compressible waste, contaminated equipment, etc.

PenreinLt OK Fe-55 81.13% 3.57E3+01 Co-60 5.87% 2.58E3+00 Cs-137 4.53% 1.99E+00 Mn-54 4.68% 2.06E3+00 Zn-65 1.20% 5.28E3-01

c. Irradiated components, control rods, etc.

Pearent eA Fe-55 51.11% 8.97E+03 Co-60 33.02% 5.79E+03 Ta-182 9.86% 1.73E+03 Mn-54 2.66% 4.66E+02 Ni-63 2.38% 4.18E+02 19

Revision 01 - August, 2003 DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 DOCKET NUMBERS: 50-010/50-237/50-249 UNIT 1, 2 & 3 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS (Cont.)

2. Estimate of Major Nuclide Composition (by type of waste) - Continued
d. Other - Contaminated Soil/Contaminated Oil Perrent OK niriesq Fe-55 70.65% 1.29E-01 Co-60 13.60% 2.48E-02 Mn-54 3.55% 6.45E-03 Ni-59 3.44% 6.25E-03 Cs-137 2.25% 4.08E-03 Ni-63 1.34% 2.43E-03 Zn-65 1.19% 2.16E-03 Sr-90 1.07% 1.95E-03
3. Solid Waste Description NIM R4RR OF SHlIPMFNTS .MO)DF OF TR ANSPORTATIGN DFTATNATIlON 3 Motor Freight (exclusive use only) CNS, Barnwell, SC 2 Motor Freight (exclusive use only) AERC, Oak Ridge, TN 51 Motor Freight (exclusive use only) GTS Duratek, Oak Ridge, TN 5 Motor Freight (exclusive use only) GTS Duratek, Kingston, TN 18 Motor Freight (exclusive use only) Envirocare, Clive UT I Motor Freight (exclusive use only) Perma-Fix, Gainsville, FL 1 Motor Freight (exclusive use only) E. Tennessee Material and Energy, Oak Ridge, TN 7 Motor Freight (exclusive use only) Studsvik, Erwin, TN B. IRRADIATED FUEL SHIPMENTS (Disposition)

WI TMRPR OF 1,RIPEMENTS MOflF OF~ TR ANSPORTATION DrSINATION None 20

Revision 01- August, 2003 DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 DOCKET NUMBER: 50-010/50-237/50-249 UNMONITORED RELEASES*

A. LIQUID

1. Number of Releases: A
2. Total Activity Releases:

B. GASEOUS

1. Number of Releases:
2. Total Activity Releases: 4 ?7pR-n4 ri A.1 In June, 1994, elevated tritium levels were discovered in the on-site storm sewers. The highest storm drain concentration measured during 2002, 87 pCi/l , was used for all of 2002. The total activity released is based on an estimated typical discharge flow of 10 gallons per minute. An estimated 1.73E-03 Ci of H-3 may have been released into the environment.

Various storm sewer locations on-site are periodically analyzed for Tritium.

A.2. From January 1, 2002 through April 30,2002, a leak was present in the Units 2/3 Cribhouse from Heating Steam system piping. The Heating Steam system at Dresden has historically been contaminated with small amounts of radioactivity.

Based upon bounding assumptions, it is estimated that a total of 2.53E-04 Ci was discharged to the environment A.3 Grab samples of the Service Water effluent are routinely collected and analyzed for radioactivity. Gamma spectroscopy analysis identified Mn-54 on one of the samples taken in 2002. A total of 1.63E-03 Ci is estimated to have been released during the period for which this sample was applicable.

A.4 Grab samples of the Wastewater Treatment System effluent are routinely collected and analyzed for radioactivity. Gamma spectroscopy analysis identified Co-60 and/or Mn-54 on several samples taken in 2002. A total of 2.52E-04 Ci is estimated to have been released via this pathway.

  • These releases are included in the Effluents Summation of all Releases Tables and in the Radiological Impact on Man.

21

Revision 01 - August, 2003 DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 DOCKET NUMBER: 50-010/50-237/50-249 UNMONITORED RELEASES* (Continued)

B. 1 The Unit I Main Turbine Floor (MTF) is used as an area to work on contaminated equipment. The ventilation, which exhausts through the Unit 1 Main Chimney, is no longer operational and the floor is at ambient pressure with the outside environment. With radiological work activities being performed on the MTF, the potential exists for airborne activity to be released to the environment through various potential release points. The estimated release through these points is 3.6E-05 Ci per year of Cs-137.

B.2 The Chemistry Hotlab ventilation exhausts directly into the environment without any monitoring. The calculated release to the environment is 2.911E-04 Ci of noble gases and 8.64E-06 Ci of iodines/particulates.

B.3 The Unit 2/3 heating steam system has low-level contamination present. During operation of the system, some steam is vented directly into the environment. A total activity of 7.23E-06 Ci is estimated to have been released to the environment from this system during 2002.

B.4 Past radiological surveys have identified low-level contamination in the East Turbine Building Ventilation ductwork. This system vents directly to the environment, therefore, a postulated release is calculated. A total activity of 3.36E-05 Ci is estimated to have been released to the environment from this system during 2002.

B.5 A functional test of the Unit 3 Isolation Condenser was conducted on January 17, 2002. In the past, low-level contamination has been introduced into the shell side of the condenser/heat exchanger, which vents directly to the environment. As a result, actuation of this system prompts sampling and isotopic analysis of the shell side contents. For this event, a total activity of 5.1 5E-05 Ci is estimated to have been released to the environment.

  • These releases are included in the Effluents Summation of all Releases Tables and in the Radiological Impact on Man.

22

Revision 01 - August, 2003 I DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2(i02 DOCKET NUMBER: 50-010 RADIOLOGICAL IMPACT ON MAN*

UNIT 1

1. Airborne Releases lkA.-:-..-

MAA!A A JJ~f rt,-

1O .D A-Ii A..4k--

SU fl U 4 l jv ~Dfl~ IJ Oa a _ _ _ _ _ __ _ _ _

Quarterly Yearly Obj. Annual Dose 1 QTR 2d QTR 3rd QTR 4e QTR Obi.

Gamma Air 5.0 mrad 2.98E-07 (e) 0.OOE+00 (e) 0.OOE+00 (e) 0.OOE+00 (e) 10.0 mrad 2.98E-07 (e)

(mra*

(MBar 10.0 mrad 4.51E-06 (e) 0.OOE+00 (e) 0.OOE+00 (e) 0.OOE+00 (e) 20.0 mrad 4.51E-06 (e)

Total Body 2.5 mrem 1.17E-06 (e) 0.OOE+00 (e) 0.OOE+00 (e) 0.OOE+00 (e) 5.0 mrem 1.17E-06 (e)

(mrem)

Skin (Mreml 7.5 mrem 3.27E-06 (e) 0.OOE+00 (e) 0.00E+00 (e) 0.00E+00 (e) 15.0 mrem 3.27E-05 (e)

Organ 7.5 mrem 1.43E-05 (ct) 6.57E-06 (c) 5.65E-06 (t) 7.87E-04 (ic) 15.0 mrem 8.07E-04 (ic)

(mrem! .. I Critical Organ Lung GILLI GILLI Liver (i)Liver

_ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Bo n e (' i e

2. Liquid Releases Maximum Doses from Act atic Effluents Quarterly ITMQTR 2"d QTR 3H QTR 4t QTR Yearly Obj. Annual Dose

_ Q b L~~~~Ob. 2QR r M4 _-QR TotalBody 1.5 mrem None None None None 3.0 mrem None Omregn 5.0 mrem None None None None 10.0 mrem None Critical Organ None None None None None

  • The doses reported include abnormal releases. These doses are the highest among the four analyzed receptors as described in parentheses [(i)=infant, (c)=child, (t)=teenager, (a)=adult, (e)=every receptor has the same value].

23

Revision 01 - August, 2003 DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 DOCKET NUMBER: 50-237 RADIOLOGICAL IMPACT ON MAN*

UNIT 2

1. Airborne Releases Maximum

... _ _ Doses

_ _ _from Airborne_ Releases

_ A..._ .__ _

Quarterly I- QTR~ Yearly Obj. Annual Dose 2EdQTR 3d QTR 4th QTR Obi.

Gamma Air arnmag A 5.0 ir mrad 1.91E-04 (e) 2.61E-04 (e) 1.72E-04 (e) 1.51E-04 (e) 10.0 mrad 7.74E-04 (e)

Beta Air 10.0 mrad 1.97E-05 (e) 1.74E-05 (e) 1.21E-05 (e) 1.02E-05 (e) 20.0 mrad 5.88E-05 (e)

Total Body 2.5 mrem 1.44E-04 (e) 1.97E-04 (e) 1.41E-04 (e) 1.38E-04 (e) 5.0 mrem 5.84E-04 (e)

(mreM) 7.5 mrem 1.62E-04 (e) 2.16E-04 (e) 1.43E-04 (e) 1.25E-04 (e) 15.0 mrem 6.46E-04 (e)

Organ 7.5 mrem 4.37E-03 (c) 3.02E-03 (c) 5.24E-03 (c) 1.66E-03 (c) 15.0 mrem 1.38E-02 (c)

Critical Organ Lung Thyroid Thyroid Thyroid Thyroid

2. Liquid Releases Maximum )oses from Aut atic Effluents Quarterly I- QTR 2 QTR 3rd QTR 4 QTR Yearly Obj. Annual Dose ObTB Total)Body 1.5 mrem 3.29E-05 (c) 2.09E-05 (c) 4.79E-04 (a) 5.50E-05 (a) 3.0 mrem 5.79E-04 (a)

Omrem 5.0 mrem 3.32E-05 (c) 2.48E-05 (c) 6.78E-04 (c) 8.02E-05 (c) 10.0 mrem 8.16E-04 (c)

Critical Organ GILLU Liver Liver Liver Liver

  • The doses reported include abnormal releases. These doses are the highest among the four analyzed receptors as described in parentheses [(i)--infant, (c)=child, (t)=teenager, (a)=adult, (e)=every receptor has the same value].

24

Revision 01- August, 2003 DRESDEN NUCLEAR POWER STATION UNITS 1, 2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 DOCKET NUMBER: 50-249 RADIOLOGICAL IMPACT ON MAN*

UNIT 3

1. Airborne Releases Maximum Doses from Airbome Releases Quarterly 2nd QT.R 3id QTR Yearly Obj. Annual Dose I- QTR 4l QTR Obi.

Gamma Air Lmmad) 5.0 mrad 4.67E-04 (e) 6.21 E-04 (e) 7.42E-04 (e) 3.34E-04 (e) 10.0 mrad 2.16E-03 (e)

Beta Air 10.0 mrad 4.73E-05 (e) 4.41 E-05 (e) 5.44E-05 (e) 2.49E-05 (e) 20.0 mrad 1.70E-04 (e)

Total Body 2.5 mrem 3.52E-04 (e) 4.69E-04 (e) 5.60E-04 (e) 2.52E-04 (e) 5.0 mrem 1.63E-03 (e)

Skirn e m)7.5 mrem 3.97E-04 (e) 5.17E-04 (e) 6.18E-04 (e) 2.78E-04 (e) 15.0 mrem 1.81E-03 (e)

Organ Omrgan 7.5 mrem 4.25E-03 (c) 2.18E-02 (c) 1.78E-02 (c) 7.38E-03 (c) 15.0 mrem 4.91E-02 (c)

Critical Organ Lung Thyroid Thyroid Thyroid

2. Liquid Releases Maximum Doses from AQ atic Effluents Quarterly I1 QTR 2a QTR 3d QTR 4 QTR Yearly Obj. Annual Dose Total Body 1.5 mrem 3.30E-05 (c) 4.83E-05 (a) 4.73E-04 (a) 5.53E-05 (a) 3.0 mrem 6.02E-04 (a)

Organ 5.0 mrem 3.32E-05 (c) 7.23E-05 (c) 6.70E-04 (c) 8.09E-05 (c) 10.0 mrem 8.56E-04 (c)

Critical Organ GI-LLI Liver Liver Liver Liver

  • The doses reported include abnormal releases. These doses are the highest among the four analyzed receptors as described in parentheses [(i)>infant, (c)=child, (t)=teenager, (a)-adult, (e)=every receptor has the same value].

25

Revision 01 - August, 2003 DRESDEN NUCLEAR POWER STATION UNITS 1,:2 AND 3 RADIOACTIVE EFFLUENT RELEASE REPORT January Through December 2002 DOCKET NUMBER: 50-010/50-237150-249 METEOROLOGICAL DATA The remaining pages of this report contain the Dresden Station meteorological site quarterly joint-frequency wind rose tables for 2002.

26

Dresden Lclear Station Jamnay-ardi, 2002 35 ft. Wind Speed and Direction l5OFt-35Ft Delta-T (F)

Iimber of Observations 2159 Values are Percent Occurrence SPBE---------------------------------- NM DDE MSM ---------------------------------- S.BILMfl ASSES ---------- -

aS I ME H iE 8 ISE SE SSE S S SW IS I IW VW1E 1T UK S UI Bs SIS 8 L 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 EU0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Ku 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.09 0.09 1'S 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

-N1 0.00 0.09 0.00 0.05 0.05 0.00 0.00 0.00 0.23 0.05 0.05 0.05 0.05 0.05 0.05 0.28 0.97 0.97 3SS 0.28 0.28 0.09 0.00 0.09 0.19 0.23 0.23 0.09 0.32 0.23 0.14 0.37 0.28 0.23 0.32 3.38 3.38 KS 0.00 0.00 0.00 0.05 0.00 0.05 0.00 0.14 0.09 0.23 0.14 0.32 0.42 0.32 0.37 0.05 2.18 2.18 is 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.05 0.00 0.05 0.05 0.09 0.00 0.32 0.32 6.95 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.09 0.23 0.09 0.05 0.65 0.65 0.00 0.00 0.00 0.00 .0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.14 0.00 0.05 0.00 0.28 0.28 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.09 0.09 0.05 0.09 0.00 0.23 0.65 0.65 1.16 0.56 1.07 0.74 0.37 0.05 0.14 0.09 0.23 0.42 0.28 0.23 0.46 0.42 0.28 0.46 6.95 6.95 0.51 0.42 0.56 L.79 0.51 0.28 0.32 0.97 1.30 1.53 1.02 0.46 1,67 1.62 0.88 1.25 14.08 14.08 0.00 0.00 0.00 0.00 0.00 0.37 0.05 0.09 0.60 1.85 2.50 0.74 0.74 0.28 0.19 0.00 7.41 7.41 0.00 0.00 0.00 0.00 0.00 0.19 0.05 0.00, 0.05 0.28 1.62 0.14 0.00 0.05 0.00 0.00 2.36 2.36 32.38 0.05 0.00 0.23 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.19 0.14 0.69 0.46 0.05 1.85 1.85 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.23 0.19 0.05 0.09 0.14 0.79 0.79 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.23 0.05 0.19 0.09 0.09 0.74 0.74 0.32 0.46 0.69 0.28 0.97 0.32 0.19 0.51 0.93 0.60 0.79 0,83 1.34 1.1 1.39 1.39 12.14 12.14 0.05 0.23 0.97 0.60 0,46 0.37 0.97 1.95 1.99 1.85 2.55 1.02 1.57 1.71 0.46 1.95 18.71 18.71 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.14 0.28 1.71 0.05 0.00 0.00 0.00 0.00 2.22 2.22 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.00 0.00 0.00 0.23 0.23 36.68 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.14 0.28 0.74 0.51 0.14 0.09 2.04 2.04 EU 0.00 0.00 .0.00 0.00 0.00 0.09 0.00 0.00 0.09 0.37 0.09 0.09 0.14 0.23 0.09 0.00 1.20 1.20 3SU 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.05 0.09 0.05 0.09 0.05 0.09 0.05 0.00- 0.00 0.56 0.56 0.19 0.00 0.65 0.00 0.05 0.09 0.09 0.93 1.39 1.07 0.46 0.37 1.95 1.39 0.65 0.37 9.63 9.63 SS 0.00 0.00 0.37 0.00 0.00 0.05 0.05 1.57 1.71 1.07 0.65 0.14 0.51 0.37 0.09 0.09 6.67 6.67 813 ISs0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 20.10

Dresde Nuclear Station Janary-Marci, 2002 35 ft. Wind 4 d and Direction lSOFt-35Ft Delta-T (F)

......... .............. ... WIID DIlECIO C SES ........---------- --------- STILI CLASSES.--------

N m 0 m I m SE SSB S S SWS ISW NKSEW IN m EU NU SU SS KS S TAL EU 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.19 0.00 0.00 0.00 0.00 0.05 0.28 0.28 1N 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.14 9 SU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.00 .0.00 0.00 0.00 0.00 0.05 0.19 0.19

- I 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.32 0.32 0.09 0.00 0.23 0.00 0.00 0.00 1.11 1.11 2 SS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.28 0.83 0.28 0.00 0.00 0.09 0.00 0.00 0.00 1.48 1.48 4 S 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 *0.00 0.00 0.00 0.00 0.00 0.00 0.00 iS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 0.00 0.00 0.00 KU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 GNU 0.00 0.00 0.00 0.00 0.00 *0.00 0.00 0.00 0.00 0.60 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 TSU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 I 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.46 0.00 0.00 0.00 0.46 0.46 2 SS 0.00 0.00 0.00 0.00 ,0.00 0.00 0.00 0.05 0.14 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.23 0.23 4 KS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 iS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 TOT 2.69 2.04 4.82 2.55 2.50 2.13 2.22 7.09 10.51 10.70 12.92 5.97 11.58 9.68 5.70 6.90 100.00 4.82 2.50 2.13 31.26 44.56 11.81 2.92 100.00 Wind Direction by Stability li D NE11E I ES SE SS S WSSE0i WE W WAm -STABILITY CSSES-0.09 0.00 0.23 0.05 0.00 0.00 0.05 0.00 0.00 0.14 0.32 0.60 0.97 1.44 0.69 0.23 4.82 Extremely Unstable 0.00 0.00 0.05 0.00 0.00 0.09 0.05 0.05 0.19 0.37 0.09 0.51 0.46 0.28 0.23 0.14 2.50 Modentely Unstable 0.09 0.00 0.09 0.00 0.00 0.00 0.00 0.09 0.23 0.05 0.23 0.37 0.19 0.32 0.09 0.37 2.13 Slightly Unstable 1.67 1.11 2.41 1.07 1.44 0.46 0.42 1.67 3.10 2.45 1.67 1.48 4.49 2.96 2.36 2.50 31.26 Neutral 0.83 0.93 1.99 1.39 1.07 0.88 1.57 5.05 6.07 5.05 4.45 1.76 4.26 3.98 1.67 3.61 44.56 Slightly Stable 0.00 0.00 0.00 0.05' 0.00 0.42 0.09 0.23 0.83 2.36 4.35 1.11 1.16 0.60 0.56 0.05 11.81 Moderately Stable 0.00 0.00 0.05 0.00 0.00 0.28 0.05 0.00 0.09 0.28 1.81 0.14 0.05 0.09 0.09 0.00 2.92 Extremely Stable Wind Direction by Wind Speed InE aE E S SE MSSSSo SISW 1 NWX6 1N TOTAL-WI SPEED CassS-0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 CALK 0.28 0.37 0.14 0.09 0.14 0.23 0.23 0.37 0.46 0.60 0.46 0.60 0.88 0.69 0.74 0.65 6.95 < 3.5mph 1.76 0.97 1.62 1.53 0.88 0.88 0.56 1.20 2.18 4.08 5.51 1.90 3.15 2.69 1.48 1.99 32.38 3.6- 7.5 qph 0.46 0.69 1.95 0.93 1.44 0.79 1.20 2.50 3.06 2.73 5.23 2.55 3.29 3.75 2.50 3.61 36.68 7.6- 12.5 mph 0.19 0.00 1.11 0.00 0.05 0.23 0.14 2.55 3.29 2.69 1.44 0.93 3.43 2.55 0.97 0.56 20.10 12.6- 18.5mh 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.42 1.39 0.60 0.28 0.00 0.32 0.00 0.00 0.09 3.20 18.6 - 24.5 mph 0.00 0.00 0.00 ' 0.00 0.00 0.00 0.00 0.05 0.14 0.00 0.00 0.00 0.51 0.00 0.00 0.00 0.69 >24.5 mph

Dresden Nuclear Station Jamnary-N[arc, 2002 300 ft. Wind Speed and Direhio 300pt-35t Delta-T (F)

Number of Observations: 2137 Values are Percent Occurrence


~-WIND DIREClIA CSESS j....... -------- K N-W---.... STISWCasSES ----------

. . . IS. I in1 SR SSI S SSW SW W w NW NN WM S KU SU SS NS RS MM 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.09 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 .0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.05 0.09 0.05 0.00 0.05 0.00 0.00 0.05 0.05 0.09 0.00 0.00 0.05 0.00 0.61 0.61 0.05 0.05 0.05 0.00 0.05 0.19 0.00 0.09 0.05 0.05 0.00 0.09 0.00 0.00 0.19 0.00 0.84 0.84 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.05 0.00 0.00 0.05 0.00 0.00 0.00 0.28 0.28 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 1.87 0.00 0.00 0.00 0.00 0.00 .0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.05 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.05 0.19 0.00 0.00 0.42 o.4 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.09 0.05 0.09 0.00 0.09 0.42 0.42 0.19 0.33 0.23 0.51 0.23 0.00 0.05 0.09 0,23 0.28 0.23 0.23 0.14 0.19 0.23 0.33 3.51 3.51 0.19 0.05 0.14 0.09 0.14 0.09 0.14 0.09 0.14 0.05 0.09 0.09 0.23 0.14 0.19 0.05 1.92 1.92 0.00 0.00 0.00 0.00 0.00 .0.00 0.00 0.00 0.00 0.05 0.05 0.14 0.14 0.00 0.00 0.00 0.37 0.37 0.09 0.09 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.00 0.33 0.33 7.02 0.00 0.00 0.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.33 0.09 0.00 0.56 0.56 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.14 0.05 0.09 0.28 0.00 0.66 0.66 0.00 0.00 0.05 0.00 0.00 0.00 0.05 0.05 0.05 0.00 0.05 0.28 0.23 0.19 0.09 0.00 1.03 1.03 1.17 0.75 1.31 1.26 0.51 0.28 0.14 0.14 0.33 0.33 0.61 0.75 0.70 0.37 0.23 0.37 9.27 9.27 0.42 0.28 0.19 0.14 0.19 0.23 0.19 0.19 .0.47 0.75 0.94 0.94 0.94 0.37 0.47 0.47 7.16 7.16 0.09 0.09 0.05 0.05 0.00 0.00 0.09 0.00 0.00 0.05 0.14 0.51 0.19 0.23 0.42 0.23 2.15 2.15 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.05 0.05 0.00 0.00 0.00 0.00 0.19 0.19 21.01 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.09 0.09 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.05 0.19 0.09 0.05 0.00 0.51 0.51 0.09 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.19 0.14 0.14 0.14 0.00 0.89 - 0.89 0.84 0.42 1.26 0.37 0.98 0.14 0.33 1.17 1.36 1.26 0.89 0.84 1.12 1.36 0.94 i.78 15.07 15.07 0.37 0.05 0.05 0.23 0.09 0.09 0.66 0.89 1.36 1.92 2.95 1.17 1.40 1.54 0.66 1.17 14.60 14.60 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.23 0.05 0.28 1.50 1.92 0.51 0.33 0.09 0.05 4.96 4.96 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.05. 0.14 0.05 0.00 0.00 0.00 0.33 0.33 36.45

Dresden Nuclear Station Jauary-March, 2002 300 ft. Wind Speed and Direction 300Ft-351t Delta-T (F)

SPD ---------------------------------- WND DIRECTION CMSSEs ------------------------------ --------- SThIm CLSSES ----------

CLMSS BE 1 ENE B BSE Si SSE S SSWSW SW 1 NEw NWUNW TM E ISO SU 11 SS KS IS TML 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.14 0.09 0.00 0.00 0.37 0.37 1K 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.09 0.14 0.09 0.23 0.37 0.05 0.00 1.08 1.08 9Su 0.00 0.00 0.09 0.00 0.00 0.05 0.00 0.00 0.23 0.14 0.14 0.09 0.23 0.19 0,00 0.00 1.17 1.17

- K 0.28 0.28 0.70 0.00 0.19 0.09 0.05 1.03 1.54 1.12 0.37 0.37 2.11 2.25 1.03 0.66 12.07 12.07 2SS 0.14 0.00 0.00 0.00 0.05 0.09 0.00 0.84 1.31 1.36 2.06 0.98 0.47 0.56 0.19 0.80 8.84 8.84 4MKS 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.05 0.09 0.47 0.42 0.19 0.00 0.00 0.00 1.26 1.26 iS 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.09 0.09 24.89 EB 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.05 0.14 0.14 GNK 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.14 0.00 0.00 0.00 0.09 0.05 0.09 0.05 0.47 0.47 T SU 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.05 0.00 0.14 0.00 0.05 0.05 0.05 0.05 0.47 0.47 N 0.09 0.00 0.28 0.00 0.00 0.00 0.00 0.19 0.51 0.66 0.14 0.28 1.59 0.42 -0.28 0.33 4.77 4.77 2 SS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.42 1.54 0.56 0.23 0.00 0.14 0.00 0.00 0.00 2.90 2.90 4 KS0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 RS0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 IM 4.26 2.57 4.73 2.81 2.48 1.26 1.97 5.80 9.55 9.36 11.32 10.29 11.61 9.69 5.85 6.46100.00 1.22 3.23 3.98 45.30 36.27 9.03 0.98 100.00 Wind Direction by Stability N E E EN I SSE SE SESW SW WSW W EW NW -STABILM CLWSSES-0.00 0.00 0.19 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.28 0.42 0.14 0.05 1.22 Extremely Unstable 0.05 0.05 0.00 0.05 0.00 0.00 0.05 0.09 0.23 0.19 0.14 0.42 0.61 0.84 0.47 0.05 3.23 derately Unstable 0.09 0.00 0.19 0.00 0.00 0.05 0.14 0.14 0.33 0.28 0.33 0.66 0.70 0.66 0.28 0.14 3.98 Slightly Unstable 2.71 1.78 3.84 2.25 1.97 0.S1 0.61 2.62 3.98 3.70 2.29 2.57 5.66 4.59 2.76 3.46 45.30 Neutral 1.17 0.42 0.42 0.47 0.51 0.70 0.98 2.53 4.87 4.68 6.27 3.28 3.18 2.62 1.68 2.48 36.27 Slightly Stable 0.14 0.14 0.05 9.05 0.00 0.00 0.14 0.33 0.09 0.51 2.15 2.99 1.08 0.56 0.51 0.28 9.03 Moderately Stable 0.09 0.19 0.05 0.00 0.00 0.00 0.05 0.09 0.05 0.00 0.14 0.23 0.09 0.00 0.00 0.00 0.98 Extremely Stable Wind Direction by Wind Speed N ME OE IW I ESE SE SSE S SSW SWWSW WNW NW W TL 'WN SPED SSES-0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 CALM 0.23 0.14 0.09 0.09 0.09 0.19 0.05 0.23 0.05 0.14 0.05 0.19 0.05 0.05 0.23 0.00 1.87 <- 3.5mph 0.51 0.47 0.42 0.61 0.37 0.09 0.23 0.23 0.37 0.37 0.42 0.75 0.66 0.61 0.42 0.47 7.02 3.6- 7.5mqph 1.68 1.22 1.73 1.45 0.70 0.51 0.47 0.42 -0.89 1.12 1.78 2.67 2.11 1.59 1.59 1.08 21.01 7.6 - 12.5mh 1.31 0.47 1.40 0.66 1.08 0.23 0.98 2.39 2.76 3.70 5.38 4.31 3.42 3.46 1.92 2.99 36.45 12.6 - 18.5 mph 0.42 0.28 0.80 0.00 0.23 0.23 O.i4 1.87 3.23 2.91 3.18 2.11 3.42 3.46 1.26 1.45 24.89 18.6 - 24.5mph 0.09 0.00 0.28 0.00 0.00 0.00 0.09 0.66 2.25 1.22 0.51 0.28 1.97 0.51 0.42 0.47 8.75 24.5 mph

Dresden kelear Station Jannary-December, 2002 35 ft. Wind peed and Direction 15OFt-35Ft Delta-T (F)

Number of Observations = 8730 Values are Percent Occurrence SP ---------------.......------------ DNM DIRECI0 ClMUSES .. . . . .. ... . . . .. . . . Sm m am ....------ -

CLASSWIWE EERIE R SE SESS$ S SSW SR EW WW E lw TL U Su D I SS KS iS TML 0.00 0.00 0.00 0.00 0.00 0.00 0.00I 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00D0.00 0.00I 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00D0.00 0.00 0.00 0.00 0.00 0.00. 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 10.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 }'0.00 0.00 0.00 0.00 0.00 *0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.00 0.01 0.00 0.01 ,0.00 0.00 0.01 0.00 0.00 0.02 0.01 0.00 0.08 0.08 0.01 0.01 0.00 0.00 0.00 0.01 0.00 0.00 0.00 0.01 0.00 0.03 0.00 0.01 0.01 0.01 0.1 0.1 0.05 0.00 0.01 0.03 0.02 0.00 0.00 0.00 0.01 .0.00 0.02 0.02 0.01 0.00 0.01 0.02 0.22 0.22 0.10 0.14 0.07 0.05 0.05 0.05 0.07 0.07 0.15 0.09 0.09 0.11 0.05 0.07 0.11 0.15 1.41 1.41 0.34 0.37 0.33 0.19 0.24 0.16 0.15 0.11 0.30 0.32 0.29 0.27 0.40 0.34 0.32 0.47 4.67 4.67 0.22 0.21 0.10 0.13 0.25 0.17 0.25 0.26 0.39 0.41 0.44 0.31 0.46 0.37 0.39 0.25 4.60 4.60 0.05 0.00 0.05 0.03 0.00 0.06 0.09 0.11 0.23 0.38 0.50 0.24 0.19 0.22 0.34 0.24 2.74 2.74 0.19 0.25 0.45 0.48 0.26 0.13 0.11 0.19 0.24 0.23 0.39 0.52 0.24 0.22 0.22 0.26 4.39 4.39 0.14 0.06 0.09 0.03 0.09 0.07 0.05 0.13 0.03 0.05 0.08 0.09 0.07. 0.08 0.08 0.05 1.18 1.18 0.10 0.03 0.11 0.02 0.05 0.05 0.07 0.06 0.08 0.06 0.14 0.08 0.06 0.08 0.10 0.17 1.26 1.26 0.72 0.56 1.08 0.78 0.50 0.27 0.42 0.48 0.42 0.52 0.46 0.69 0.71 0.71 0.62 0.90 9.85 9.85 0.64 0.92 1.59 1.21 1.63 1.05 0.53 1.51 1.41 1.28 1.04 0.69 1.82 1.42 1.21 1.24 19.20 19.20 0.00 0.02 0.07 0.00 0.24 0.53 0.15 0.39 0.68 1.07 1.31 0.44 0.41 0.22 0.14 0.15 5.80 5.80 0.00 0.00 0.00 0.00 0.00 0.11 0.03 0.03 0.10 0.23 0.92 0.13 0.02 0.03 0.02 0.02 1.66 1.66 43.33 0.11 0.01 0.37 0.25 0.22 0.11 0.11 0.17 0.13 0.24 0.38 0.47 0.22 0.44 0.39 0.32 3.94 3.94 0.02 0.01 0.08 0.05 0.03 0.05 0.01 0.09 0.08 0.09 0.10 0.22 0.17 0.10 0.02 0.10 1.24 1.24 0.02 0.02 0.07 0.01 0.11 0.03 0.06 0.07 0.05 0.09 0.09 0.21 0.06 0.17 0.03 0.07 1.17 1.17 0.27 0.37 0.94 0.34 0.80 0.411 0.30 0.54 0.68 0.63 0.63 0.52 1.05 0.85 0.81 0.69 9.83 9.83 0.05 0.13 0.68 0.31 0.44 0.37 0.50 1.41 1.76 1.25 1.40 0.60 1.10 0.74 0.68 0.73 12.13 12.13 0.00 0.00 0.00 0.00 0.03 0.01 0.02 0.02 0.08 0.13 0.52 0.02 0.00 0.00 0.00 0.00 0.84 0.84 0.00 0.00 0.00 0.00 0.00 0.02 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.07 0.07 29.21 0.00 0.00 0.00 0.00 0.00 0.00 0.02 0.00 0.10 0.36 0.21 0.13 0.23 0.17 0.06 0.02 1.29 1.29 0.00 0.00 0.00 0.00 0.00 0.02 0.00 0.06 0.08 0.19 0.05 0.05 0.06 0.08 0.02 0.00 0.61 0.61 0.00 0.00 0.02 0.00 0.00 0.00 0.01 0.03 0.13 0.10 0.08 0.03 0.03 0.01 0.01 0.00 0.47 0.47 0.06 '0.00 0.21 0.00 0.24 0.29 0.15 0.30 0.69 0.62 0.37 0.25 0.89 0.50 0.26 0.21 4.93 4.93 0.00 0.00 0.09 0.00 0.01 0.10 I0.08 0.68 1.18 0.79 0.37 0.11 0.42 0.16 0.11 0.09 4.20 4.20 0.00 0.00 0.00 0.00 0.00 0.00 10.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 I0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

Dresden Nuclear Station January-Decumer, 2002 35 ft. Wind Speed and Direction 150Ft-35Ft Delta-T (F)

SPM ---------------------------------- NM DI RE MM C -------- ------------- --------- sMBILm M ----------

MmASS DU NE 3ERE lS SESSE S SSW SW WSWI ENW NW Tol KU SU I SS NS IsT HU0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.00 0.01 0.05 0.00 0.09 0.01 0.00 0.01 0.18 0.18 1KU 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.03 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.10 0.10 9Su 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.01 0.00 0.00 0.01 0.07 0.07

- N 0.00 0.00 0.00 0.00 0.01 0.01 0.00 0.05 0.17 0.29 0.06 0.03 0.09 0.00 0.01 0.00 0.72 0.72 2SS 0.00 0.00 0.00 0.00 0.00 1.00 0.01 0.13 0.40 0.21 0.00 0.03 0.05 0.00 0.00 0.00 0.82 0.82 I4NS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Is 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.u 0.00 .0.00 0.00 0.11 0.11 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.03 0.05 0.01 0.00 0.00 0.01 0.00 0.00 0.00 0.10 0.10 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.22 TOT 3.10 3.10 6.41 3.93 5.23 4.10 3.13 7.01 9.69 9.69 10.01 6.29 9.05 7.03 6.01 6.20 100.00 9.89 3.24 3.18 26.85 41.13 11.24 4.47 100.00 find Direction by Stability N EE E IISE SE SSE S SSW SW a I N J -SMILITY LSSES-0.31 0.26 0.82 0.73 0.48 0.25 0.26 0.38 0.47 0.84 1.03 1.11 0.78 0.86 0.68 0.62 9.89 xtremely nstable 0.17 0.08 0.17 0.08 0.13 0.15 0.07 0.29 0.23 0.39 0.23 0.39 0.30 0.27 0.14 0.16 3.24 Moderately Unstable 0.17 0.06 0.22 0.07 0.18 0.08 0.14 0.16 0.31 0.25 0.33 0.34 0.17 0.26 0.16 0.27 3.18 Slightly U1table 1.16 1.07 2.29 1.17 1.60 1.03 0.84 1.43 2.11 2.14 1.60 1.60 2.91 2.13 1.82 1.95 26.85 Neutral 1.03 1.41 2.69 1.72 2.31 1.68 1.27 3.93 5.10 3.86 3.09 1.71 3.80 2.67 2.33 2.53 41.13 Slightly Stable 0.22 0.23 0.17 0.13 0.53 0.71 O.4 0.68 1.15 1.60 2.26 0.77 0.87 0.58 0.53 0.40 11.24 Moderately Stable 0.05 0.00 0.05 0.03 0.00 0.19 0.13 0.15 0.33 0.61 1.47 0.37 0.22 0.25 0.37 0.26 4.47 bltrely Stable Wind Direction by Wind Speed N HE l IRU I ISE Si SSE S SSW SWI SwI NNW W wTOML -WIRUSPEED MSSES-0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 CAL X 0.77 0.72 0.57 0.44 0.56 0.46 0.56 0.63 1.08 1.21 1.35 1.00 1.11 1.03 1.20 1.15 13.84 e 3.5 mph 1.80 1.84 3.39 2.53 2.77 2.21 1.36 2.79 2.97 3.42 4.33 2.62 3.33 2.76 2.39 2.79 43.33 3.6- 7.5Mph 0.48 0.54 2.13 0.96 1.64 1.01 1.01 2.30 2.77 2.43 3.16 2.03 2.60 2.30 1.94 1.91 29.21 7.6 - 12.5 vph 0.06 0.00 0.32 0.00 0.25 0.41 0.16 1.07 2.18 2.06 1.07 0.57 1.64 0.93 0.47 0.32 11.50 12.6 - 18.5 mph 0.00 0.00 0.00 0.00 0.01 0.01 0.03 0.18 0.65 0.55 0.10 0.07 0.24 0.01 0.01 0.02 1.90 18.6- 24.5 iph 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.03 0.05 0.01 0.00 0.00 0.13 0.00 0.00 0.00 0.22 >24.5 iph

Dresden Wuclear Station Jamary-December, 2002 300 ft. find Speed and DirecdOA 300Ft-351t Delta-T (F) unber of bservations= 8647 Values are Percent Occurrence SPEED ----------- ----------- I.W DIM Na SES ------------ ---------------------


--------- SABhITT CLASSES ---------

WAs I E I E E iS SE SS S SSW SW SW IE KwWTOTAL zU NU Su N SS S S TTAL 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00. 0.00 -0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0,00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.00 0.02 0.02 0.01 0.01 0.00 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.00 0.01 0.00 0.01 0.07 0.07 0.07 0.03 0.03 0.03 0.05 0.05 0.05 0.02 0.05 0.06 0.03 0.05 0.02 0.08 0.02 0.03 0.68 0.68 0.05 0.03 0.05 0.03 0.02 0.10 0.00 0.02 0.02 0.01 0.01 0.06 0.02 0.00 0.07 0.02 0.53 0.53 0.03 0.03 0.00 0.01 0.00 0.03 0.03 0.03 0.01 0.01 0.02 0.06 0.02 0.02 0.02 0.02 0.38 0.38 0.01 0.01 0.01 0.01 0.00 0.00 0.01 0.00 0.03 0.01 0.00 0.00 0.06 0.01 0.02 0.01 0.21 0.21 0.01 0.00 0.08 0.21 0.05 0.02 0.02 0.07 0.08 0.09 0.12 0.22 0.15 0.03 0.02 0.02 1.20 1.20 0.05 0.03 0.05 0.08 0.03 0.07 0.05 0.08 0.15 0.06 0.10 0.15 0.05 0.06 0.06 0.09 1.16 1.16 0.06 0.05 0.03 0.10 0.06 0.12 0.12 0.10 0.03 0.03 0.08 0.14 0.08 0.07 0.07 0.08 1.23 1.23 0.37 0.19 0.39 0.68 0.36 0.21 0.29 0.34 0.28 0.27 0.32 0.27 0.28 0.24 0.29 0.29 5.05 5.05 0.10 0.13 0.16 0.38 0.25 0.19 0.12 0.23 0.14 0.14 0.17 0.20 0.25 0.20 0.20 0.12 2.97 2.97 0.05 0.02 0.05 0.12 0.08 0.09 0.06 0.12 0.16 0.03 0.14 0.24 0.14 0.06 0.07 0.02 1.45 1.45 0.02 0.05 0.07 0.12 0.06 0.00 0.00 0.01 0.03 0.03 0.08 0.12 0.02 0.01 4.00 0.01 0.64 0.64 0.10 0.15 0.24 0.25 0.13 0.03 0.06 0.08 0.06 0.10 0.20 0.25 0.03 0.16 0.10 0.10 2.07 2.07 0.05 0.05 0.06 0.15 0.09 0.02 0.14 0.08 0.09 0.06 0.13 0.13 0.05 0.12 0.14 0.05 1.39 1.39 0.10 0.08 0.16 0.08 0.13 0.02 0.10 0.12 0.12 0.12 0.13 0.24 0.16 0.16 0.10 0.10 1.93 1.93 0.72 0.75 1.19 1.58 0.67 0.35 0.29 0.60 0.43 0.61 0.64 0.74 0.81 0.67 0.68 0.81 11.54 11.54 0.45 0.32 0.43 0.81 0.72 0.34 0.56 0.51 0.57 0.76 0.81 0.69 0.84 0.44 0.35 0.53 9.12 9.12 0.08 0.13 0.15 0.12 0.06 0.06 0.14 0.25 0.12 0.12 0.40 0.59 0.62 0.17 0.24 0.21 3.46 3.46 0.06 0.03 0.06 0.00 0.01 0.00 0.03 0.07 0.05 0.10 0.09 0.07 0.08 0.05 0.06 0.03 0.80 0.80 0.03 0.07 0.07 0.01 0.08 0.02 0.00 0.01 0.01 0.12 0.07 0.06 0.03 0.13 0.08 0.14 0.94 0.94 0.05 0.05 0.06 0,01 0.06 0.03 0.00 0.10 0.03 0.13 0.08 0.10 0.12 0.08 0.09 0.07 1.06 1.06 0.05 0.02 0.09 0.00 0.07 0.05 0.02 0.07 0.09 0.14 0.17 0.21 0.14 0.17 0.07 0.05 1.41 1.41 0.68 0.53 1.08 0.34 1.09 0.31 0.19 0.65 0.84 0.74 0.88 0.54 0.94 1.23 0.76 1.01 11.80 11.80 0.60 0.46 0.44 0.12 0.51 0.51 0.64 0.99 1.28 1.79 1.93 0.74 1.06 1.12 0.88 0.82 13.90 13.90 0.07 0.06 0.06 0.00 0.03 0.28 0.35 0.17 0.19 0.29 1.02 0.91 0.24 0.17 0.21 0.17 4.22 i.22 0.05 0.00 0.00 0.00 0.00 0.01 0.01 0.08 0.01 0.12 0.12 0.09 0.03 0.01 0.01 0.03 0.58 0.58 33.91

Dresden Nuclear Statimn January-Decmber, 2002 300 ft. Wind Speed and Diredtion 300Ft-35Ft Delta-T (F)

SPED ---------------------------------- FM DIRECIION CLSSES ------------------------------- --------- sM'Im CJSSES ----------

MS N in1 NE DE3 ISE SE SSE S SSW SW WSW 11 NNW NW l TOTAL BU Ka SU SS S TOTAL 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.05 0.07 0.02 0.05 0.03 0.06 0.03 0.02 0.35 0.35 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.10 0.14 0.10 0.03 0.06 0.12 0.02 0.00 0.60 0.60 0.00 0.01 0.02 0.00 0.01 0.01 0.00 0.00 0.13 0.19 0.05 0.08 0.09 0.07 0.01 0.01 0.68 0.68 0.20 0.23 0.36 0.00 0.30 0.34 0.05 0.38 0.79 0.77 0.32 0.27 1.13 0.94 0.46 0.37 6.90 6.90 0.09 0.02 0.05 0.00 0.02 0.15 0.05 0.56 1.06 1.16 1.10 0.43 0.46 0.25 0.23 0.34 5.97 5.97 0.07 0.00 0.00 0.00 0.00 0.02 0.02 0.00 0.08 0.05 0.15 0.13 0.08 0.02 0.00 0.00 0.62 0.62 0.00 0.00 0.00 0.00 0.00 0.02 0.03 0.00 0.01 0.05 0.07 0.01 .0.01 0.00 0.00 0.00 0.21 0.21 15.33 la 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 0.01 0.00 0.00 0.06 0.01 0.00 0.01 0.12 0.12 GWU0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.05 0.01 0.00 0.01 0.06 0.03 0.02 0.01 0.21 0.21 TSU 0.00 0.00 0.00 0.00 Q.00 0.00 0.01 0.01 0.03 0.06 0.05 0.00 0.05 0.02 0.01 0.01 0.25 0.25 N 0.07 0.00 0.07 0.00 0.03 0.08 0.00 0.12 0.30 0.43 0.12 0.13 0.58 0.23 0.22 0.14 2.51 2.51 2 SS0.00 M.oo 0.00 0.00 0.00 0.02 0.03 0.13 0.73 0.49 0.14 0.06 0.08 0.01 0.03 0.02 1.75 1.75 4 KS0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.01 is 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4.85 TOT 4.36 3.56 5.50 5.26 4.97 3.56 3.48 6.04 8.25 9.36 9.88 8.06 8.96 7.26 5.68 5.82 100.00 4.68 4.44 5.57 38.49 34.24 10.14 2.43 100.00 Wind Direction by Stability IN li ERR IE ISE SESSBS S SW WEWI w E N TAL -STABILM lASSES-0.15 0.22 0.39 0.47 0.25 0.08 0.09 0.16 0.22 0.39 0.40 0.58 0.31 0.39 0.24 0.31 4.68 Extremely Unstable 0.15 0.13 0.16 0.24 0.19 0.13 0.20 0.29 0.43 0.39 0.42 0.43 0.32 0.42 0.34 0.22 4.44 Moderately Unstable 0.22 0.17 0.31 0.20 0.27 0.20 0.25 0.30 0.40 0.53 0.49 0.67 0.52 0.51 0.27 0.27 5.57 Slightly Unstable 2.10 1.73 3.12 2.64 2.50 1.33 0.86 2.10 2.68 2.88 2.31 1.99 3.76 3.39 2.44 2.65 38.49 Neutral 1.30 0.97 1.12 1.34 1.53 1.31 1.39 2.44 3.80 4.35 4.16 2.17 2.73 2.02 1.76 1.85 34.24 Slightly Stable 0.30 0.24 0.25' 0.24 0.17 0.49 0.60 0.58 0.57 0.50 1.73 1.93 1.11 0.45 0.54 0.43 10.14 Moderately Stable 0.14 0.09 0.14 0.13 0.07 0.03 0.09 0.16 0.14 0.31 0.36 0.29 0.21 0.08 0.09 0.09 2.43 Extremely Stable Wind Direction by Wind Speed I MNE aE ESE SE SSE S SSW SWSE Kw WEw N NWN TOM -Wm SPED ASE-0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 CALM 0.17 0.13 0.09 0.10 0.07 0.19 0.09 0.09 0.12 0.09 0.08 0.16 0.13 0.14 0.14 0.12 1.91 < 3.5#ph 0.66 0.46 0.83 1.69 0.89 0.69 0.65 0.95 0.88 0.66 1.02 1.33 0.97 0.67 0.71 0.64 13.69 3.6- 7.5mph 1.56 1.51 2.29 3.00 1.80 0.82 1.32 1.71 1.42 1.87 2.39 2.72 2.60 1.77 1,68 1.84 30.31 7.6- 12.5 ph 1.53 1.19 1.79 0.47 1.84 1.21 1.20 2.08 2.46 3.32 4.27 2.66 2.57 2.91 2.10 2.29 33.91 12.6 - 18.5 mph 0.37 0.27 0.43 0.00 0.34 0.54 0.16 0.95 2.22 2.42 1.82 0.99 1.87 1.46 0.76 0.74 15.33 18.6 - 24.5 mph 0.07 0.00 0.07 0.00 0.03 0.10 0.06 0.25 1.14 0.99 0.30 0.20 0.82 0.31 0.29 0.20 4.85 ) 24.5 mph

Dresden kclear Station riMU4me, 2002 35 ft. Wind Speed and Direction 15OFt-35Ft Delta-T (F) lumber of Observations 2177 Values are Percent Occurrence SpD ------------------ WMN DIEL2'YIG C mA E ------------------ ----; rMBIM WlSRSE------

ClASIINENEBE I UE 8a8on S aS aENSE W.i09w vaNWM~A zu Ka EU I . Ss NS is TM~

0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.05 0.00 0.00 0.05 0.00 0.00 0.14 0.14 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.09 0.00 0.00 0.05 0.09 0.00. 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.28 0.28 0.18 0.23 0.18 0.00 0.05 0.14 0.14 0.09 0.09 0.18 0.14 0.09 0.05 0.05 0.23 0.23 2.07 2.07 0.09 0.14 0.60 0.28 0.41 0.23 0.18 0.09 0.55 0.51 0.23 0.28 0.37 0.23 0.23 0.51 4.92 4.92 0.32 0.18 0.05 0.05 0.18 0.23 0.23 0.32 0.32 0.23 0.60 0.37 0.37 0.32 0.23 0.37 4.36 4.36 0.05 0.00 0.00 0.09 0.00 0.00 0.14 0.09 0.32 0.37 0.51 0.32 0.09 0.05 0.14 0.05 2.20 2.20 14.01 0.14 0.18 0.23 0.18 0.18 0.00 0.00 0.18 0.18 0.23 0.28 0.37 0.18 0.05 0.14 0.14 2.66 2.66 0.28 0.18 0.14 0.05 0.05 0.09 0.00 0.18 0,09 0.09 0.05 0.09 0.00 0.09 0.18 0.09 1.65 1.65 0.23 0.09 0.23 0.00 0.09 0.00 0.14 0.18 0.14 0.05 0.23 0.05 0.05 0.09 0.09 0.09 1.75 1.75 0.78 0.32 1.61 0.92 0.69 0.32 1.06 0.73 0.46 0.69 0.60 1.01 0.87 0.83 0.92 0.87 12.68 12.68 0.28 0.28 1.42 1.10 1.98 1.75 0.78 1.70 1.10 1.19 1.24 0.83 1.88 1.33 1.75 0.78 19.38 19.38 0.00 0.00 0.00 0.00 0.14 0.28 0.32 0.64 0.37 0.78 0.87 0.32 0.18 0.18 0.18 0.09 4.36 4.36 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.05 0.00 0.14 0.78 0.18 0.09 0.05 0.00 0.00 1.33 1.33 0.00 0.05 0.41 0.32 0.05 0.09 0.00 0.05 0.09 0.05 0.09 0.18 0.09 0.55 0.37 0.51 2.89 2.89 0.00 0.05 0.14 0.00 0.00 0.14 0.00 0.14 0.09 0.23 0.00 0.18 0.28 0.18 0.00 0.05 1.47 1.47 0.05 0.05 0.0O 0.00 0.14 0.09 0.09 0.18 0.00 0.23 0.05 0.37 0.05 0.37 0.05 0.14 1.93 1.93 0.37 0.60 1.61 0.60 0.92 0.51 0.41 1.01 0.64 0.55 0.32 0.60 0.96 1.06 0.87 0.46 11.48 11.48 0.05 0.05 0.46 0.18 0.51 0.78 0.60 2.25 1.98 1.19 0.92 0.55 0.55 0.51 0.46 0.37 11.39 11.39 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.09 0.05 0.05 0.18 0.05 0.00 0.00 0.00 0.00 0.51 0.51 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.05 29.72 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.23 0.28 0.18 0.09 0.00 0.18 0.09 0.00 1.06 1.06 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.14 0.14 0.05 0.09 0.05 0.09 0.00 0.00 0.64 0.64 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.09 0.23 0.09 0.00 0.05 0.00 0.00 0.00 0.00 0.51 0.51 0.00 0.00 0.18 0.00 0.18 0.73 0.05 0.23 .0.55 0.51 0.32 0.05 0.37 0.51 0.14 0.05 3.86 3.86 0.00 0.00 0.00 0.00 0.00 0.14 0.14 0.51 1.79 0.96 0.14 0.00 0.05 0.00 0.23 0.05 4.00 4.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

Dresden Nuclear Station pril-Jume, 2002 35 ft. Wind Speed and Directimn lS0Ft-35Pt Delta-T (F)

MDDI1C'1I~f WSS,-----------------

.W--------K---------- - S BILIT CLASSES ---------- -

CLASS IXIK E INS N ISE SE SSE S SR SSW m I ow vNEWVTOL SU mSU K ES KS IS1OTAL 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.37 0.05 0.00 0.00 0.41 0.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.18 0.18 O.CO 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 .0.00 0.0s 0.00 0.00 0.00 0.09 0.09 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.00 0.28 0.37 0.00 0.05 0.09 0.00 0.00 0.00 0.87 0.87 0.00 0.00 0.00 I0.00 0.00 0.00 0.00 0.00 0.09 0.55 0.00 0.14 0.00 0.00 0.00 0.00 0.78 0.78 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2.34 rU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 GNU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 TSU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2Ss 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.00. 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4IS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 TOT 2.94 2.39 7.35 3.81 5.70 5.65 4.36 9.00 9.88 9.78 7.85 6.29 7.03 6.80 6.29 4.87 100.00 7.17 4.00 4.55 30.96 40.51 9.23 3.58 100.00 Mind Direction by Stability N MES 15IK155 ElS SR SSE S 5S8 SWNEWSW INW NWNW TOTAL -STABILY CLASSES-0.14 0.23 0.64 0.51 0.23 0.09 0.00 0.28 0.51 0.55 0.60 0.4 0.64 0.87 0.60 0.64 7.17 Extremely Unstable 0.32 0.23 0.28 0.05 0.05 0.23 0.00 0.46 0.37 0.55 0.09 0.37 0.32 0.37 0.18 0.14 4.00 Koderately Wustable 0.37 0.14 0.32 0.05 0.32 0.09 0.28 0.46 0.41 0.37 0.28 0.46 0.14 0.46 0.14 0.28 4.55 Slightly Unstable 1.33 1.15 3.58 1.52 1.88 1.75 1.65 2.07 2.02 2.30 1.38 1.79 2.34 2.43 2.16 1.61 30.96 Neutral 0.41 0.46 2.48 1.56 2.89 2.89 1.70 4.55 5.51 4.46 2.53 1.79 2.85 2.07 2.66 1.70 40.51 Slightly Stable 0.32 0.18 0.05 0.05 0.32 0.55 0.60 1.06 0.73 1.06 1.6S 0.73 0.55 0.51 0.41 0.46 9.23 Ibderately Stable 0.05 0.00 0.00 0.09 0.00 0.05 0.14 0.14 0.32 0.51 1.33 0.51 0.18 0.09 0.14 0.05 3.58 ftwely Stable Wind Direction by Wind Speed I1HE a IKE I En SESSESSSW SIKSEKINw NW oTAm -WN SPEED aS-0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 CA LM 0.78 0.55 0.83 0.46 0.73 0.60 0.69 0.64 1.29 1.29 1.52 1.06 0.87 0.69 0.83 1.19 14.01 ' 3.5 qh 1.70 1.06 3.63 2.25 3.12 2.48 2.30 3.67 2.34 3.17 4.04 2.85 3.26 2.62 3.26 2.07 43.82 3.6- 7.5 qb 0.46 0.78 2.71 1.10 1.61 1.65 1.15 3.72 2.85 2.10 1.61 1.93 1.93 2.66 1.75 1.52 29.72 7.6- 12.5 ph 0.00 0.00 0.18 0.00 0.18 0.87 0.23 0.92 2.94 1.98 0.69 0.28 0.46 0.78 0.46 0.09 10.06 12.6 -18.5 up 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.05 0.46 1.01 0.00 0.18 0.51 0.05 0.00 0.00 2.34 18.6 - 24.5 uph 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.05 >24.5tqh

Dresden Nuclear Station Ipril-June, 2002 300 ft. Wind Speed and Direction 300Ft-35Ft Delta-T (F)

Number of servatins - 2103 Values are Percent Occurrence SPERD------------------ WMN DIRECII CIISSE------------------ TBILTY MISSES------ -

camS I IM NE I~IS E SEml S SSW SWWSWI NW NWNE mmTASu Ka Su I Ss MS ESTOTAL 0.00 0.00 0.00 0.00 0.00 0.00. 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.oo 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 I0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00' 0.00 0.00 0.00 0,00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 *0.00 0.00 0.00 0.0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 9.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 .0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.05 0.05 0.10 0.05 0.00 0.00 0.05 0.05 0.05 0.00 0.00 0.05 0.00 0.00 0.05 0.05 0.10 0.57 0.57 0.00 0.10 0.10 0.10 0.00 0.14 0.00 0.00 0.00 0.00 0.00 0.14 0.05 0.00 0.05 0.05 0.71 0.71 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.0o0 0.00 0.00 0.00 0.00 0.05 0.00 0.05 0.10 0.10 0.00 0.00 0.00 0.00 *0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.43 0.00 0.00 0.00 0.05 0.05 0.00 0.00 0.10 0.00 0.10 0.10 0.05 0.10 0.00 0.00 0.00 0.52 0.52 0.14 0.05 0.14 0.10 0.00 0.14 0.05 0.14 .0.24 0.00 0.14 0.19 0.05 0.00 0.05 0.05 1.47 1.47 0.14 0.14 0.10 0.14 0.05 0.14 0.29 0.05 0.10 0.00 0.05 0.10 0.05 0.00 0.10 0.10 1.52 1.52 0.52 0.19 0.62 0.81 0.38 0.14 0.52 0.48 0.38 0.24 0.43 0.14 0.24 0.19 0.33 0.33 5.94 5.94 0.19 0.10 0.14 0.24 0.14 0.19 0.10 0.38 0.24 0.19 0.29 0.24 0.19 0.29 0.14 0.10 3.14 3.14 0.14 0.00 0.00 0.00 0.05 0.05 0.05 0.10 0.14 0.05 0.24 0.14 0.05 0.05 0.05 0.00 1.09 1.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.05 0.00 0.00 0.00 0.00 0.14 0.14 0.00 0.05 0.10 0.14 0.05 0.00 0.00 0.00 0.00 0.10 0.00 0.14 0.00 0.00 0.05 0.00 0.62 0.62 0.05 0.05 0.10 0.19 0.00 0.10 0.05 0.10 0.19 0.14 0.10 0.10 0.05 0.14 0.10 0.05 1.47 1.47 0.19 0.10 0.29 0.00 0.19 0.05 0.24 0.29 0.24 0.14 0.05 0.24 0.19 0.14 0.19 0.10 2.62 2.62 0.38 0.76 1.47 1.85 0.71 0.43 0.24 1.00 0.33 0.52 0.71 0.67 0.71 0.90 1.33 0.48 12.51 12.51 0.43 0.00 0.38 0.43 0.67 0.62 1.00 0.81 0.62 0.95 1.14 0.67 0.90 0.71 0.29 0.67 10.27 10.27 0.00 0.19 0.05 0.00 0.10 0.10 0.14 0.19 0.14 0.10 0.29 0.62 0.57 0.10 0.05 0.14 2.76 2.76 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.10 0.14 0.19 0.10 0.00 0.10 0.05 0.67 0.67 30.91 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.05 0.00 0.14 0.05 0.29 0.67 0.67 0.00 0.10 0.14 0.00 0.05 0.05 0.00 0.24 0.00 0.05 0.14 0.10 0.10 0.24 0.19 0.14 1.52 1.52 0.00 0.05 0.19 0.00 0.00 0.14 40.10 0.10 0.10 0.14 0.05 0.43 0.14 0.24 0.10 0.14 1.90 1.90 0.86 0.43 2.00 0.48 0.90 0.57 10.14 0.90 0.62 0.62 0.52 0.52 0.76 1.43 0.95 1.09 12.79 12.79 0.48 0.10 0.14 0.19 0.67 1.00 I1.00 1.95 1.00 1.47 1.71 0.81 0.86 1.09 1.00 0.71 14.17 14.17 0.00 0.00 0.00 0.00 0.05 0.24 I019 0.10 0.38 0.14 0.71 0.76 0.14 0.05 0.14 0.10 3.00 3.00 0.00 0.00 0.00 0.00 0.00 0.00 I0.00 0.00 0.00 0.19 0.19 0.10 0.05 0.05 0.00 0.00 0.57 0.57

Dresden Nuclear Statimi July-September, 2002 35 ft. Wind Speed and Direction 150Ft-35Ft Delta-T (F) uaer of Observations . 2192 Values are Percent Occurrence SPEED --------------- WVIDDIDECI'ION ASSES ------------------------------ --------- STABILITYIASSES ---------

Ws I mE E E ISE EE w S W S IISW WE W i TOTALEU 1U Su I SS N is TAL 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 10.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 10.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.09 0.00 0.05 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.05 0.00 0.18 0.18 0.05 0.00 0.05 0.09 0.00 0.00 0.00 0.00 0.05 0.00 0.09 0.09 0.05 0.00 0.00 0.05 0.50 0.50 0.00 0.09 0.05 0.05 0.05 0.05 0.05 0.14 0.27 0.14 0.18 0.27 0.05 0.14 0.14 0.09 1.73 1.73 0.68 0.87 0.41 0.41 0.32 0.18 0.05 0.09 0.27 0.27 0.41 0.36 0.41 0.46 0.50 0.55 6.25 6.25 0.46 0.64 0.36 0.32 .0.55 0.32 0.55. 0.18 0.50 0.55 0.55 0.32 0.55 0.64 0.59 0.41 7.48 7.48 0.14 0.00 0.00 0.05 0.00 0.23 0.18 0.23 0.27 0.64 1.14 0.55 0.50 0.55 0.96 0.78 6.20 6.20 22.45

'U 0.50 0.78 1.41 1.73 0.87 0.50 0.46 0.59 0.78 0.68 1.14 1.41 0.59 0.41 0.27 0.64 12.77 12.77 m 0.00 2.01 KU0.14 0.05 0.14 0.05 0.32 0.14 0.14 0.23 0.05 0.05 0.27 0.18 0.14 0.09 0.05 2.01 4 Su 0.05 0.00 0.09 0.00 0.00 0.14 0.14 0.00 0.09 0.05 0.18 0.18 0.14 0.09 0.23 0.05 1.41 '1.41

- I 0.23 0.46 0.55 1.05 0.46 0.36 0.36 0.82 0.50 0.59 0.50 0.73 0.73 0.68 0.36 0.36 8.76 8.76 7SS 0.41 1.32 3.28 2.05 1.82 1.14 0.41 2.33 2.28 1.37 1.19 0.68 0.82 0.82 0.41 1.05 21.40 21.40 KS 0.00 0.09 0.27 0.00 0.55 0.91 0.18 0.41 0.50 0.23 0.73 0.27 0.23 0.18 0.09 0.05 4.70 4.70 is 0.00 0.00 0.00 0.00 0.00 0.09 0.09 0.09 0.09 0.09 0.68 0.14 0.00 0.05 0.05 0.09 1.46 1.46 52.51 0.18 0.00 0.82 0.64 0.78 0.36 0.27 0.41 0.41 0.78 1.28 1.28 0.41 0.18 0.05 0.00 7.85 7.85 0.00 0.00 0.09 0.14 0.09 0.05 0.05 0.14 0.18 0.05 M.g8 0.23 0.09 0.05 0.00 0.05 1.37 1.37 0.00 0.00 0.09 0.00 0.14 0.05 0.14 0.05 0.14 0.09 0.14 0.09 0.09 0.05 0.00 0.00 1.05 1.05 0.00 0.00 0.46 0.23 0.32 0.27 0.32 0.18 0.55 0.82 0.41 0.23 0.09 0.09 0.00 0.05 4.01 4.01 0.05 0.00 0.91 0.14 0.32 0.00 0.23 0.78 2.05 0.82 0.73 0.23 0.00 0.09 0.09 0.14 6.51 6.51 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.14 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.32 0.32 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 21.17 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.09 0.87 0.32 0.05 0.00 0.00 0.00 0.00 1.41 1.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.09. 0.14 0.05 0.00 0.00 0.00 0.00 0.00 0.41 0.41 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.23 0.00 0.00 0.00 0.00 0.00 0.00 0.36 0.36 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.36 0.55 0.23 0.05 0.00 0.00 0.00 0.05 1.28 1.28 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.05 0.09 0.00 0.05 0.05 0.00 0.00 0.00 0.32 0.32 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 3.79

Dresde N ear Station July-September, 2002 35 ft. Wind Speed and Direction l50Ft-35Ft Delta-T (F)

SPED ---------------------------------- N DIRECI0ON SSES -------------------------------- S.T. m sWM ---------

- sw CLSS I XRE E NE I ISE SE SSE 6 SSW SW W W EEw NKWoTTM Su mu Su I Ss NS Is TOTAL SU0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 1K 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 9Su 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00

-IN 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 2$S 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 NS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 is 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 o0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 .0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0,00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 o.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 *.oo 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 T3 2.87 4.33 9.03 6.93 6.66 4.88 3.70 6.93 9.85 9.26 10.45 7.39 4.93 4.56 3.83 4.38 100.00 22.17 3.97 3.33 15.83 34.53 12.50 7.66 100.00 Wind Direction by Stability NE E B ISE S3SE SS WSd s WWSW U I NW TM -STABILIfTY MME 0.68 0.78 2.28 2.37 1.64 0.91 0.82 1.00 1.28 2.37 2.74 2.74 1.00 0.59 0.32 0.64 22.17 Extremely Unstable 0.14 0.09 0.23 0.18 0.41 0.23 0.18 0.50 0.32 0.27 0.50 0.41 0.23 0.14 0.09 0.05 3.97 Moderately Unstable 0.09 0.00 0.23 0.09 0.14 0.18 0.27 0.05 0.41 0.36 0.41 0.36 0.27 0.14 0.23 0.09 3.33 Slightly Unstable 0.23 0.55 1.05 1.32 0.82 0.68 0.73 1.19 1.69 2.14 1.32 1.28 0.87 0.91 0.50 0.55 15.83 Yeutral, 1.14 2.19 4.61 2.60 2.46 1.32 0.68 3.28 4.65 2.55 2.33 1.32 1.28 1.37 1.00 1.73 34.53 Slightly Stable 0.46 0.73 0.64 0.32 1.19 1.23 0.73 0.59 1.14 0.82 1.32 0.59 0.78 0.82 0.68 0.46 12.50 Merately Stable 0.1 0.00 0.00 0.05 0.00 0.32 0.27 0.32 0.36 0.73 1.82 0.68 0.50 0.59 1.00 0.87 7.66 Extremely Stable wind Direction by Wind Speed It NNE E MM I ISE SSES S SSW SW WESW I E W WTM -TIMD SPED MSSES-0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 CILM 1.32 1.64 0.91 0.91 0.91 0.87 0.82 0.64 1.37 1.64 2.37 1.60 1.55 1.78 2.24 1.87 22.45 < 3.5Imh 1.32 2.69 5.75 4.88 4.01 3.28 1.78 4.47 4.29 3.06 4.70 3.60 2.65 2.33 1.46 2.24 52.51 3.6 - 7.5 ph 0.23 0.00 2.37 1.14 1.73 0.73 1.00 1.55 3.47 2.60 2.78 2.05 0.68 0.46 0.14 0.23 21.17 7.6 -12.5 uh 0.00 0,00 0.00 0.00 0.00 0.00 0.09 0.27 0.73 1.87 0.59 0.14 0.05 0.00 0.00 0.05 3.79 12.6 -18.5 uh 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.09 18.6- 24.5 uph 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 >24.5mph

Dresden Nuclear Station July-Septeiber, 2002 300 ft. find Speed and Direction 300Ft-35Ft Delta-T (F) lumber of Observations - 2206 Values are Percent Occurrence SPD ---------------------------------- WiD DIRECOIIf MsS .................................. S.. BIIM MM -------- -

WSS I111 I ISE S S 'SSWiSW W I ' IN 1g NW 7ML E UKSU S SSI NS IsTAL 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00. 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 10.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 '0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 =0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.18 0.18 0.09 0.00 0.00 0.05 0.09 0.09 0.09 0.05 0.05 0.18 0.05 0.09 0.05 0.18 0.00 0.05 1.09 1.09 0.14 0.00 0.05 0.05 0.00 0.09 0.00 0.00 0.05 0.00 0.05 0.00 0.05 0.00 0.05 0.05 0.54 0.54 0.05 0.05 0.00 0.05 0.00 0.09 0.05 0.00 0.05 0.00 0.09 0.09 0.05 - 0.05 0.05 0.05 0.68 0.68 0.05 0.00 0.05 0.05 0.00 0.00 0.00 0.00 0.14 0.05 0.00 0.00 0.23 0.05 0.09 0.05 0.73 0.73 3.22 0.05 0.00 0.32 0.77 0.14 0.09 0.09 0.18 0.32 0.27 0.36 0.77 0.45 0.09 0.05 0.05 3.99 3.99 0.00 0.05 0.05 0.23 0.14 0.14 0.14 0.14 0.36 0.23 0.18' 0.23 0.09 0.05 0.05 0.18 2.22 2.22 0.09 0.05 0.05 0.23 0.18 0.23 0.09 0.27 0.05 0.05 0.23 0.27 0.23 0.18 0.14 0.00 2.31 2.31 0.14 0.00 0.23 0.82 0.41 0.45 0.50 0.73 0.41 0.45 0.41 0.36 0.50 0.32 0.36 0.18 6.26 6.26 0.05 0.09 0.23 0.86 0.45 0.36 0.05 0.23 0.09 0.18 0.23 0.18 0.27 0.23 0.18 0.23 3.90 3.90 0.00 0.09 0.18 0.45 0.27 0.23 0.14 0.23 0.32 0.05 0.23 0.50 0.27 0.09 0.09 0.00 3.13 3.13 0.00 0.09 0.18 0.41 0.18 0.00 0.00 0.00 0.05 0.09 0.09 0.23 0.09 0.05 0.00 0.05 1.50 1.50 23.30 0.32 0.54 0.73 0.86 0.45 0.14 0.23 0.32 0.23 0.32 0.77 0.82 0.14 0.32 0.14 0.18 6.48 6.48 0.14 0.09 -0.09 0.41 0.36 0.00 0.36 0.09 0.18 0.09 0.41 0.27 0.09 0.09 0.09 0.05 2.81 2.81 0.09 0.09 0.14 0.32 0.27 0.05 0.09 0.09 0.09 0.23 0.32 0.23 0.09 0.09 0.05 0.05 2.27 2.27 0.27 0.27 0.23 1.72 0.45 0.36 0.59 0.86 0.50 0.73 0.54 0.73 0.86 0.41 0.27 0.27 9.07 9.07 0.27 0.36 0.91 2.40 1.36 0.27 0.68 0.68 .0.50 0.63 0.54 0.59 0.32 0.18 0.27 0.27 10.24 10.24 0.23 0.18 0.36 0.41 0.14 0.05 0.27 0.73 0.18 0.23 0.77 0.54 0.68 0.14 0.27 0.18 5.35 5.35 0.23 0.09 0.23 0.00 0.05 0.00 0.14 0.27 0.00 0.09 0.18 0.05 0.18 0.18 0.09 0.05 1.81 1.81 38.03 0.00 0.27 0.18 0.00 0.32 0.09 0.00 0.05 0.05 0.36 0.23 0.18 0.00 0.27 0.00 0.00 1.99 1.99 0.09 0.09 0.09 0.00 0.14 0.09 0.00 0.05 0.09 0.18 0.18 0.18 0.05 0.00 0.00 0.00 1.22 1.22 0.05 0.05 0.09 0.00 0.09 0.05 0.00 0.14 0.27 0.14 0.27 0.09 0.09 0.09 0.00 0.00 1.41 1.41 0.45 0.68 0.45 0.27 0.77 0.09 0.09 0.14 0.86 0.68 0.91 0.36 0.14 0.23 0.00 0.09 6.21 6.21 0.59 0.73 1.18 0.00 0.95 0.59 0.45 10.82 2.45 2.45 1.13 0.50 0.32 0.32 0.63 0.41 13.51 13.51 0.00 0.14 0.18 0.00 0.09 0.36 0.86 40.27 0.14 0.09 0.23 0.54 0.09 0.18 0.27 0.09 3.54 3.54 0.14 0.00 0.00 0.00 0.00 0.00 0.05 0.23 0.00 0.00 0.14 0.05 0.05 0.00 0.00 0.09 0.73 0.73

Dresden lear Station July-September, 2002 300 ft. Wind Speed and Direction 300Ft-35Ft Delta-T (F)

SPEED --- NM DIE0C CSSES V Nm------W-v-A-L------

.. .zswu SES ---

s1-WIas I NE NE RISE Si 8 S SSW SI WW I 0 VW w MM SU NU SU SS KS BS T0A 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.05 0.27 0.05 0.00 0.00 0.00 0.00 0.00 0.45 0.45 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.18 0.09 0.00 0.00 0.00 0.00 0.00 0.36 0.36 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.27 0.00 0.05 0.00 0.00 0.00 0.00 0.41 0.41 0.14 0.00 0.18 0.00 0.00 0.00 0.00 0.05 0.36 0.82 0.36 0.14 0.00 0.05 0.00 0.05 2.13 2.13 0.14 0.09 0.09 0.00 0.00 0.14 0.00 0.14 0.54 0.95 0.32 0.09 0.00 0.00 0.09 0.09 2.67 2.67 0.05 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.09 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.27 0.27 0.00 0.00 0.00 0.00 0.00 0.05 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.14 RU0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 GNU0.00 0,00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 '0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 TSU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.05 0.00 0.00 0.05 0.23 0.23 2SS 0.00 0.00 0.00 0.00 0.00. 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 -0.00 0.00 0.00 0.05 0.05 4 KS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 iS 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0,00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.41 TOT 3.90 4.17 6.44 10.38 7.30 4.13 5.08 6.71 8.52 10.52 9.52 8.16 5.39 }.81 3.22 2.77 100.00 12.96 6.66 6.62 24.98 30.92 12.96 4.90 100.00 Wind Direction by Stability N M KR E 1. ISE8 SSS So SR SIE W NNWTM -sTBILM CSSIS-0.36 0.82 1.22 1.63 0.91 0.32 0.36 0.54 0.63 1.27 1.45 1.77 0.59 0.68 0.18 0.23 12.96 Ixtremely Unstable 0.27 0.23 -0.23 0.63 0.63 0.23 0.50 0.27 0.68 0.73 0.86 0.68 0.23 0.14 0.14 0.23 6.66 Koderately Unstable 0.27 0.27 0.27 0.59 0.54 0.32 0.18 0.50 0.45 0.68 0.91 0.63 0.41 0.36 0.18 0.05 6.62 Slightly UIstable 1.09 0.95 1.09 2.86 1.72 1.00 1.27 1.81 2.18 2.99 2.27 1.68 1.59 1.18 0.63 0.68 24.98 Neutral 1.18 1.27 2.45 3.31 2.77 1.45 1.18 1.86 3.63 4.22 2.27 1.41 0.95 0.73 1.22 1.04 30.92 Slightly Stable 0.32 0.45 0.73 0.91 0.50 0.77 1.31 1.22 0.77 0.41 1.36 1.68 1.09 0.45 0.68 0.32 12.96 Moderately Stable 0.41 0.18 0.45 0.45 0.23 0.05 0.27 0.50 0.18 0.23 0.41 0.32 0.54 0.27 0.18 0.23 4.90 Etremely Stable Wind Direction by Wind Speed N ME3 IB IInS SE SSE S SSWISW WW I O1IWKI L -WNM SPEED ClASSES-0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 CALM 0.36 0.09 0.09 0.23 0.09 0.27 0.14 0.05 0.27 0.23 0.23 0.18 0.36 0.27 0.18 0.18 3.22 < 3.5 wph 0.32 0.36 1.22 3.76 1.77 1.50 1.00 1.77 1.59 1.31 1.72 2.54 1.90 1.00 0.86 0.68 23.30 3.6- 7.5mh 1.54 1.63 2.67 6.12 3.08 0.86 2.36 3.04 1.68 2.31 3.54 3.22 2.36 1.41 1.18 1.04 38.03 7.6 - 12.5 ph 1.31 1.95 2.18 0.27 2.36 1.27 1.45 1.68 3.85 3.90 3.08 1.90 0.73 1.09 0.91 0.68 28.60 12.6 - 18.5 uh 0.36 0.14 0.27 0.00 0.00 0.23 0.14 0.18 1.13 2.54 0.91 0.27 0.00 0.05 0.09 0.14 6.44 18.6 - 24.5 h 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.23 0.05 0.05 0.05 0.00 0.00 0.05 0.41 N24.5 uph

Dresden Nuclear Station October-December, 2002 35 ft. Wind Speed and Direction l5OFt-35Ft Delta-T (F) lumber of Obserations: 2202 Values are Percent Occurrence SPEED ---------------------------------- KM DIREII 1CLASSES ---------- --------- SS ---------- -

cmSSI ME E 1E IB SE ESSEIS SSW SR IS IfW NW I1W TOIL N KUNSU N S KS is TOM 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 .0.00 0.00 0.00 0.00 .0.00 .0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 .0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.09 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.05 0.00 0.05 0.14 0.14 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.09 0.09 0.23 0.14 0.05 0.09 0;05 0.00 0.09 0.05 0.00 0.00 0.00 0.05 0.05 0.05 0.05 0.00 0.86 0.86 0.32 0.18 0.23 0.09 0.14 0.05 0.14 0.27 0.27 0.18 0.27 0.32 0.45 0.41 0.32 0.50 4.13 4.13 0.09 0.00 0.00 0.09 0.27 0.09 0.23 0.41 0.64 0.64 0.45 0.23 0.50 0.18 0.36 0.18 4.36 4.36 0.00 0.00 0.14 0.00 .0.00 0.00 0.05 0.14 0.27 0.50 0.32 0.09 0.14 0.23 0.18 0.14 2.18 2.18 fl.85

'u 0.09 0.05 0.14 0.00 0.00 0.00 0.00 0.00 0.00' 0.00 0.14 0.14 0.09 0.18 0.36 0.23 1.41 1.41 KU0.14 0.00 0.09 0.05 0.00 0.05 0.05 0.09 0.00 0.05 0.00 0.00 0.00 0.14 0.05 0.09 0.77 0.77 I8u 0.09 0.05 0.14 0.09 0.09 0.05 0.00 0.00 0.09 0.14 0.05 0.00 0.00 0.05 0.09 0.32 1.23 1.23

- N 0.73 0.91 1.09 0.41 0.so 0.36 0.14 0.27 0.50 0.36 0.45 0.77 0.77 0.91 0.91 1.91 10.99 10.99 7SS 1.36 1.63 1.09 0.91 2.18 1.04 0.59 1.04 0.95 1.04 0.73 0.77 2.91 1.91 1.82 1.86 21.84 21.84 Ks 0.00 0.00 0.00 0.00 0.27 0.54 0.05 0.41 1.23 1.41 1.14 0.41 0.50 0.23 0.09 0.45 6.72 6.72 is 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.27 0.41 0.59 0.05 0.00 0.00 0.05 0.00 1.50 1.50 44.46 0.23 0.00 0.00 0.00 0.05 0.00 0.18 0.23 0.00 0.14 0.14 0.23 0.23 0.32 0.68 0.73 3.13 3.13 0.09 0.00 0.05 0.05 0.05 0.00 0.00 0.05 0.05 0.09 0.23 0.23 0.14 0.14 0.00 0.18 1.32 1.32 0.00 0.05 0.09 0.05 0.18 0.00 0.00 0.05 0.05 0.05 0.14 0.14 0.05 0.09 0.00 0.05 0.95 0.95 0.41 0.41 1.00 0.27 1.00 0.54 0.27 0.45 0.59 0.54 1.00 0.41 1.82 1.14 1.00 0.86 11.72 11.72 0.05 0.23 0.36 0.32 0.415 0.32 0.23 0.68 1.04 1.14 1.41 0.59 2.27 0.68 1.68 0.50 n.94 11.94 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.14 0.14 0.00 0.00 0.00 0.00 0.00 0.32 0.32 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 29.38 la 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.14 0.18 0.09 0.18 0.00 0.00 0.00 0.68 0.68 1I1K 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.00 0.00 0.05 0.00 0.00 0.00 0.18 0.18 3SU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.23 0.05 0.05 0.00 0.05 0.00 0.45 0.45

-IK 0.05 0.00 0.00 0.00 0.73 0.32 0.05 0.00 0.45 0.36 0.45 0.54 1.27 0.14 0.27 0.36 5.00 5.00 1$s0.00 0.00 0.00 0.00 0.05 0.23 0.14 0.54 1.18 1.04 0.68 0.27 1.09 0.27 0.14 0.23 5.86 5.86 KSS0.00 0.00 0.00 0.00 0.00 0.00 10.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Rs 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 12.17

Dresden Nuclear Station Octdber-December, 2002 35 ft. wind Spe4d and Direction 10Bt-35OL Delta-T (F)

SPIED ------------------------------ - VWID DIRECrIM WSSES --------------------------------- ------.- SWT ABLT ----------

Ass N IRE X ENE I ESE Ss SSE S W SW WS I EW NW E0TOL u K SU -N SS SIS1 0.00 0.00. 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 lID 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00O 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.00 0.09 9 SU0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 .0.00 .0.00 0.00 0.00 0.00 0.00 0.00

-NK0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.09 0.41 0.14 0.09 .0.05 0.00 0.05 0.00 0.86 0.86 2SS 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.23 0.68 0.00 0.00 0.00 0.09 0.00 0.00 0.00 1.04 1.04 4 KS0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 is 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Ku 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 .0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 *0.00 0.00 TSU 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 2 SS 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.14 0.14 0.00 0.00 0.00 0.00 0.00 0.00 4 KS0.00 0.00 0.00 0.00 0.00 0.00 0.00 o.oo 0.00 0.00 0.00 0.00 0.00 0.00 is 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1TD3.91 3.63 4.45 2.41 6.04 3.72 2.23 5.04 8.54 9.04 8.86 5.50 12.67 7.13 8.22 8.63 100.00 5.31 2.50 2.72 29.43 44.96 11.40 3.68 100.00 Wind Direction by Stability I NIIE 1 IEEISE a SSE S SSW SWWS 11 NW WNI 7TML W -STM IL Ma S-0.32 0.05 0.14 0.00 0.05 0.00 0.18 0.23 0.09 0.27 0.45 0.45 0.50 0.54 1.09 0.95 5.31 Extremely Unstable 0.23 '0.00 0.14 0.09 0.05 0.05 0.05 0.14 0.05 0.36 0.23 0.27 0.18 0.32 0.05 0.32 2.50 Moderately Unstable 0.14 0.09 0.23 0.14 0.27 0.05 0.00 0.05 0.18 0.23 0.41 0.18 0.09 0.14 0.18 0.36 2.72 Slightly Unstable 1.41 1.45 2.13 0.77 2.27 1.23 0.54 0.82 1.63 1.68 2.04 1.86 3.95 -2.23 2.27 3.13 29.43 Neutrall 1.73 2.04 1.68 1.32 2.82 1.63 1.14 2.86 4.18 3.41 3.09 1.95 6.81 3.27 3.95 3.09 44.96 Slightly Stable 0.09 0.00 0.00 0.09 0.59 0.64 0.27 0.82 1.86 2.18 1.73 0.64 1.00 0.41 0.45 0.64 11.40 Moderately Stable 0.00 0.00 0.14 0.00 0.00 0.14 0.05 0.14 0.54 0.91 0.91 0.14 0.14 0.23 0.23 0.14 3.68 EItremely Stable Wind Direction by Wind Speed N IRE iENE 8 KS! SE SSE S S Sa I W m E w mm -KINID SPEE CLASSES-0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 CALM 0.68 0.32 0.41 0.27 0.45 0.14 0.50 0.86 1.18 1.32 1.04 0.73 1.14 0.95 1.00 0.86 11.85 c 3.5iph 2.41 2.63 2.54 1.45 3.04 2.18 0.82 1.82 3.04 3.41 3.09 2.13 4.27 3.41 3.36 4.86 44.46 3.6 - 7.5 ph 0.77 0.68 1.50 0.68 1.77 0.86 0.68 1.45 1.73 2.09 3.04 1.59 4.50 2.36 3.36 2.32 29.38 7.6 - 12.5 ph 0.05 0.00 0.00 0.00 0.77 0.54 0.18 0.54 1.77 1.73 1.54 0.95 2.63 0.41 0.45 0.59 12.17 12.6 -18.5 ph 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.27 0.77 0.50 0.14 0.09 O.14 0.00 0.05 0.00 2.00 18. 6 - 24.5 mph 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 >24.5ph

Dresden Nelear Station Octer-Decer, 2002 300 ft. lind Speed and Direction 300Bt-35Ot Delta-T PF) umber of tsenations c 2201 Values are Percent Ocurrence SPED - - - I--DD-------W DC SES ------------------------------ ---- MB mLIS--S STA s ------

WISS ME E E I IESE SS S SSW SW U I ME WIN MN TA E KUC U SS KSS IAL 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 I0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 O.N0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0,00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 .0.00 0.00 0.00 0.00 0.00 .0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.05 0.05 0.00 0.05 0.05 0.00 0.05 0.05 0.00 0.00 0.14 0.00 0.00 0.00 0.05 0.09 0.00 0.00 0.45 0.45 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 0.05 0.05 0.00 0.00 0.00 0.05 0.09 0.05 0.00 0.00 0.00 0.14 0.00 0.00 0.05 0.00 0.45 0.45 0.00 0.00 0.00 0.00 .0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.05 1.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.05 0.05 0.05 0.18 0.18 0.00 0.05 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.09 0.05 0.00 0.00 0.14 0.14 0.50 0.50 0.00 0.00 0.00 0.05 0.00 0.09 0.05 0.05 0.00 0.09 0.05 0.09 0.00 0.00 0.05 0.14 0.64 0.64 0.64 0.23 0.50 0.59 0.41 0.23 0.09 0.05 0.09 0.09 0.23 0.32 0.23 0.27 0.23 0.32 4.50 4.50 0.00 0.27 0.14 0.32 0.27 0.09 0.18 0.23 0.09 0.14 0.09 0.27 0.32 0.14 0.27 0.09 2.91 2.91 0.05 0.00 0.00 0.00 0.00 0.09 0.05 0.14 0.18 0.00 0.05 0.18 0.09 0.09 0.14 0.09 1.14 1.14 0.00 0.00 0.05 0.05 0.05 0.00 0.00 0.05 0.09 0.00 0.14 0.14 0.00 0.00 0.00 0.00 0.55 0.55 10.40 zu 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.14 0.23 0.50 0.50 Kg 0.00 0.00 0.05 0.00 0.00 0.00 0.14 0.09 0.00 0.00 0.00 0.00 0.00 0.14 0.09 0.09 0.59 0.59 ISu 0.14 0.14 0.18 0.00 0.05 0.00 0.05 0.05 0.09 0.09 0.09 0.23 0.14 0.23 0.09 0.27 1.82 1.82

- I 1.04 1.23 1.77 1.50 1.00 0.32 0.18 0.41 0.55 0.86 0.68 0.82 0.95 1.00 0.91 2.09 15.31 15.31 ISs 0.68 0.64 0.23 0.23 0.64 0.23 0.36 0.36 0.68 0.73 0.64 0.59 1.23 0.50 0.36 0.73 8.81 8.81 2KS 3.00 0.05 0.14 0.00 0.00 0.09 0.05 0.09 0.14 0.09 0.41 0.68 1.04 0.23 0.23 0.27 3.50 3.50

.is 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.23 0.00 0.00 0.05 0.00 0.05 0.05 0.50 0.50 31.03 0.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0,00 0.05 0.05 0.00 0.14 0.09 0.23 0.27 0.95 0.95 0.09 0.00 0.00 0.00 0.05 0.00 0.00 0.14 0.05 0.18 0.00 0.09 0.14 0.00 0.14 0.14 1.00 1.00 0.05 0.00 0.05 0.00 0.18 0.00 0.00 0.05 0.00 0.14 0.36 0.14 0.18 0.23 0.05 0.05 1.45 1.45 0.59 0.59 0.64 0.23 1.68 0.45 0.18 0.41 0.55 0.41 1.18 0.45 1.73 1.91 1.18 1.09 13.27 13.27 0.95 0.95 0.36 0.05 0.32 0.36 0.45 0.36 0.32 1.32 1.95 0.50 1.68 1.54 1.23 1.00 13.36 13.36 0.27 0.09 0.05 0.00 0.00 0.50 0.32 0.09 0.18 0.64 1.64 0.45 0.23 0.14 0.32 0.45 5.36 5.36 0.05 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.05 0.27 0,09 0.09 0.00 0.00 0.05 0.05 0.68 0.68 36.07

Dresden Nucear Station Octte-Denedber, 2002 300 ft. Wind Speed and Directio 300Ft-35Ft Delta-T (F)

SPED KIM DIIB0 i0r WSm


--------- sTIwLmn ----------

WSS x E NEE 8R Is SESS I SSW SW 1WS I NEWD NEW TOMA U KU SU i SS SES OTAL 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.05 0.09 0.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.09 0.00 0.00 0.00 0.00 0.00 0.14 0.14 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.14 0.00 .0.09 0.14 0.00 0.05 0.05 0.45 0.45 0.14 0.27 0.14 0.00 0.59 0.45 0.00 0.09 0.55 0.82 0.36 0.36 2.00 0.73 0.36 0.50 7.36 7.36 0.09 0.00 0.00 0.00 0.05 0.09 0.18 0.23 0.95 1.18 1.27 0.32 1.00 0.41 0.45 0.41 6.63 6.63 0.23 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.00 0.05 0.09 0.00 0.14 0.05 0.00 0.00 0.64 0.64 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.05 0.18 0.18 0.00 0.00 0.00 0.00 0.00 0.45 0.45 0.00 0.00 0.00 0.00 *0.00 0.00 0.00 0.00 0.00 40.00 10.00 0.00 0.00 0.00 .0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.00 0.00 0.00 0.00 0.05 0.05 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.09 0.00 0.00 0.00 0.00 0.18 0.00 0.27 0.55 0.41 0.27 0.09 0.50 0.23 0.50 0.18 3.27 3.27 0.00 0.00 0.00 0.00 0.00 0.0 9 0.14 0.09 0.68 0.59 0.32 0.09 0.18 0.05 0.00 0.09 2.32 2.32 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 5.63 TOT 5.36 4.59 4.32 3.00 5.36 3.50 2.59 3.32 6.09 8.72 10.31 6.32 12.13 8.18 7.31 8.91 100.00 1.77 2.27 4.41 44.16 34.08 1.09 2.23 100.00 Eind Direction by Stability N IDE i BEI 151 SSE S SW 1 WE Wn i OTAL -S7ETAIM CLASSES-0.23 0.00 0.00 0.00 0.00 *0.00 0.00 0.00 0.00 0.05 0.05 0.09 0.14 0.18 0.41 0.64 1.77 Extremely Unstable 0.09 0.05 0.05 0.00 0.05 0.00 0.14 0.27 0.05 0.23 0.18 0.18 0.14 0.14 0.36 0.36 2.27 Moderately sutable 0.18 0.14 0.23 0.05 0.23 0.09 0.09 0.14 0.09 0.45 0.50 0.55 0.45 0.50 0.23 0.50 4.41 Slightly Unstable 2.50 2.36 3.09 2.32 3.73 1.68 0.45 1.23 2.41 2.59 2.73 2.04 5.45 4.23 3.18 4.18 44.16 Neutral 1.73 1.86 0.73 0.59 1.32 0.86 1.32 1.27 2.73 3.95 4.27 1.77 4.41 2.64 2.32 2.32 34.08 Slightly Stable 0.59 0.18 0.18 0.00 0.00 0.77 0.55 0.36 0.50 0.77 2.18 1.45 1.50 0.50 0.73 0.82 11.09 Moderately Stable 0.05 0.00 0.05 0.05 0.05 0.09 0.05 0.05 0.32 0.68 0.41 0.23 0.05 0.00 0.09 0.09 2.23 Extremely Stable Eind Direction by Wind Speed I E EE ISE SS S S SWSNWE I w NWeTL -WNSPE CSSES-0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.05 0.09 0.05 0.00 0.09 0.09 0.14 0.05 0.14 0.00 0.00 0.14 0.05 0.14 0.05 0.05 1.09 < 3.5sph 0.68 0.55 0.68 1.00 0.73 0.50 0.36 0.55 0.45 0.32 0.64 1.09 0.64 0.55 0.86 0.82 10.40 3.6 - 7.5 ph 1.95 2.04 2.36 1.73 1.68 0.64 0.77 1.00 1.59 2.00 1.82 2.36 3.41 2.09 1.86 3.73 31.03 7.6 - 12.5 qah IAce O 2.14 1.64 1.09 0.27 2.23 1.36 0.95 1.04 1.14 3.00 5.27 1.73 4.09 3.91 3.18 3.04 36.07 72.6 -18.5 ph 0.45 0.27 0.14 0.00 0.64 0.64 0.23 0.32 1.54 2.41 2.00 0.77 3.27 1.23 0.86 1.00 15.77 18.6 - 24.5 ph 0.09 0.00 0.00 0.00 0.00 0.27 0.14 0.36 1.23 1.00 0.59 0.23 0.68 0.27 0.50 0.27 5.63 >24.5 oph