Orise Final Letter Report for Analytical Results for Eight Water Samples, Batch Four, from the Vicinity of the Dresden Generating Station
ML061860585
Person / Time
Site: Dresden 
Issue date: 06/28/2006
From: Condra D
Oak Ridge Institute for Science & Education
To: Snell W
NRC/RGN-III
References
FOIA/PA-2010-0209, IR-06-007, RFTA-06-001
Download: ML061860585 (5)


Text

lune 28,2006 Mr. William Snell U.S. Nuclear Regulatory Commission Rcgion 111 2443 Warrenville Road lisle, 11. 60532-4351 OAK RlDQE INSTITUTE FOR SCIENCE AND EDUCATION SUBJECT FINAL LETTER RE- -AT FOR ANALYTICAL RESULTS FOR EIGHT WATER SAMPLES, BATCH FOUR, FROM THE VICINITY OF THE DRESDEN GENERATING STATION, DRESDEN, ILLINOIS

[INSPECTION REPORT NO. 050-00237/2006-0071 (RFTA NO.06-001)

Dear Mr. Snek The Oak Ridge Institute for Science and Education (ORISE) received eight water samples on May 31, 2006 which were collected in the vicinity of the Dresden Generating Station in llresdcn, Illinois. This letter report contains the origmal data submitted on June 16, 2006 and the total radiostrontium data. The chain-of-custody identified one water sample to he analyzed hy gamma spectroscopy (GS), four samples to be analyzed for tritium, and four samples to he analyzed for total radiostrontium, The sample identifications and collection data are presented in Table 1. The GS data are presented in lahle 2. The tritium data are presented in Table 3.

The total radiostrontium data are presented in Table 4. The pertinent procedure references are provided in the specific tables.

OKISEs Quality Control (QC) requirements were met for these analyses. The QC filcs are available for your review upon request.

My contact information is listed below. You may also contact Wade Ivey at 865.576.9184 with any questions or comments.

Dale Condra, Manager Laboratory RDC:WPI:ar Enclosure C:

B. Watson, NMSS/DWMEP/DD/SP 7E18 E. Abelquist, ORISE E. &ox-Davin, NRC/NMSS/TWFN 8A23 G. Bonano, NRC Region 111 S. Kirk, ORISE Iilc 1694 RECEIVE0 JUL 0 5 Mo6

TABLE 1 SAMPLE IDENTIFICATIONS AND COLLECTION DATA DRESDEN GENERATING STATION DRESDEN, ILLINOIS ORISE NRC Region I11 Sample ID Sample ID 1694W0049 D-06-4-01 1694W0051 D-06-4-03 1694W0054 D-06-4-06 1

1694W0056 I

D-06-4-08 Collection Collection Date Time

TABLE 2 ORISE Sample ID 1694WOO53 CONCENTRATIONS OF SELECTED GAMMA EMITTING RADIONUCLIDES IN A SELECTED WATER SAMPLE BY GAMMA SPECTROSCOPY CP1, REVISION 15 DRESDEN GENERATING STATION DRESDEN, ILLINOIS NRC Region 111 Radionuclide Concentrations' @Ci/L)

Sample ID Co-58 CO-60 cs-w4 cs-l37 D-06-4-05

-3.4 f 3.1b 0.2 i 2.8 -0.7 i 2.7 3.6

_+ 6.6

TABLE 3 Sample ID 1694W0049 1694W0051 1694W0053 1694W0055 CONCENTRATIONS OF TRITIUM IN SELECTED WATER SAMPLES BY LIQUID SCINTILLATION ANALYSIS AP2, REVISION 15; CP4, REVISION 3 DRESDEN GENERATING STATION DRESDEN, ILLINOIS Sample ID and MDCs" @Ci/L)

D-06-4-01 10

?

llob (180)

D-06-4-03

-30 110 (1 80)

D-06-4-05 30

?

110 (180)

D-06-4-07 70 110 (180)

TABLE 4 1694W0050 1694W0052 1694W0054 1694WOO56 D-06-4-02

-1.07

  • 0.86b (1.71 D-06-4-04 0.2 f 1.0 (1.9)

D-06-4-06 0.25 0.89 (1.57 D-06-4-08 0.8

  • 1.0 (1 8)