MONTHYEARML0312804312003-05-0808 May 2003 Amendments 212 & 193, Revising Technical Specifications to Modify Surveillance Requirement to Be Consistent with Design of Reactor Building Access Openings Project stage: Other ML0312902412003-05-0808 May 2003 Technical Specification Pages for Amendments 212 & 193 Application Dated September 30, 2002, as Supplemented by Letters Dated October 17, 2002, and April 2, 2003 Project stage: Acceptance Review 2003-05-08
[Table View] |
|
---|
Category:Technical Specification
MONTHYEARRA-23-0279, Supplement to Application to Adopt Risk-Informed Completion Times TSTF-505, Revision 2 and Application to Adopt 10 CFR 50.69, Risk-informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power2023-11-0202 November 2023 Supplement to Application to Adopt Risk-Informed Completion Times TSTF-505, Revision 2 and Application to Adopt 10 CFR 50.69, Risk-informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power RA-18-0190, License Amendment Request to Revise Technical Specifications to Adopt Risk-Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b2023-02-16016 February 2023 License Amendment Request to Revise Technical Specifications to Adopt Risk-Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b RA-22-0091, Application to Revise Technical Specifications to Adopt TSTF-554, Revision 1, Revise Reactor Coolant Leakage Requirements2023-02-16016 February 2023 Application to Revise Technical Specifications to Adopt TSTF-554, Revision 1, Revise Reactor Coolant Leakage Requirements RA-22-0118, License Amendment Request to Revise Restrictive Technical Specification Surveillance Requirement Frequencies2023-02-0101 February 2023 License Amendment Request to Revise Restrictive Technical Specification Surveillance Requirement Frequencies RA-22-0080, Independent Spent Fuel Storage Installation, McGuire, Units 1 & 2, Independent Spent Fuel Storage Installation, Request for an Exemption to the Requirements of Certificate of Compliance No. 1031 for the NAC Magnastor Storage System2022-04-0707 April 2022 Independent Spent Fuel Storage Installation, McGuire, Units 1 & 2, Independent Spent Fuel Storage Installation, Request for an Exemption to the Requirements of Certificate of Compliance No. 1031 for the NAC Magnastor Storage System RA-21-0302, Application to Revise Technical Specifications to Adopt TSTF-569, Rev. 2, Revise Response Time Testing Definition2022-02-24024 February 2022 Application to Revise Technical Specifications to Adopt TSTF-569, Rev. 2, Revise Response Time Testing Definition RA-20-0107, Duke Energy Progress, LLC, and Duke Energy Carolinas, LLC, Application to Revise Technical Specifications to Adopt TSTF-541, Add Exceptions to Surveillance Requirements for Valves and Dampers Locked in the Actuated Position2022-01-18018 January 2022 Duke Energy Progress, LLC, and Duke Energy Carolinas, LLC, Application to Revise Technical Specifications to Adopt TSTF-541, Add Exceptions to Surveillance Requirements for Valves and Dampers Locked in the Actuated Position RA-21-0027, Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections2021-09-16016 September 2021 Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections RA-20-0207, Duke Energy - Application to Revise the Technical Specification for Engineered Safety Feature Actuation System (ESFAS) Instrumentation2020-12-0303 December 2020 Duke Energy - Application to Revise the Technical Specification for Engineered Safety Feature Actuation System (ESFAS) Instrumentation RA-19-0006, License Amendment Application to Relocate Technical Specification Unit/Facility Staff Qualification ANSI N18.1-1971, ANSI/ANS-3.1-1978 and ANSI/ANS-3.1-1981 Requirements to the Duke Energy Corporation Quality Assurance Program Description2019-07-0808 July 2019 License Amendment Application to Relocate Technical Specification Unit/Facility Staff Qualification ANSI N18.1-1971, ANSI/ANS-3.1-1978 and ANSI/ANS-3.1-1981 Requirements to the Duke Energy Corporation Quality Assurance Program Description RA-18-0232, Proposed Editorial Error Correction of Technical Specification (TS) 3.0, Surveillance Requirement Applicability, SR 3.0.5 and Proposed Removal of Expired TS Footnotes from the MNS2019-02-0505 February 2019 Proposed Editorial Error Correction of Technical Specification (TS) 3.0, Surveillance Requirement Applicability, SR 3.0.5 and Proposed Removal of Expired TS Footnotes from the MNS RA-18-0166, Supplement to Non-Voluntary License Amendment Request (LAR) to Correct Non-Conservative Technical Specification 3.4.11 - PORVs2018-09-13013 September 2018 Supplement to Non-Voluntary License Amendment Request (LAR) to Correct Non-Conservative Technical Specification 3.4.11 - PORVs ML18191A5452018-07-10010 July 2018 Attachment 2 - McGuire Technical Specification 3.8.1 Bases Marked Up Pages RA-18-001, Attachment 2 - McGuire Technical Specification 3.8.1 Bases Marked Up Pages2018-07-10010 July 2018 Attachment 2 - McGuire Technical Specification 3.8.1 Bases Marked Up Pages RA-18-000, Duke Energy Progress, LLC and Duke Energy Carolinas, LLC - Submittal of License Amendment Application to Remove Heaters from Ventilation System Technical Specifications2018-05-10010 May 2018 Duke Energy Progress, LLC and Duke Energy Carolinas, LLC - Submittal of License Amendment Application to Remove Heaters from Ventilation System Technical Specifications RA-18-0001, Duke Energy Progress, LLC and Duke Energy Carolinas, LLC - License Amendment Application to Remove Heaters from Ventilation System Technical Specifications2018-05-10010 May 2018 Duke Energy Progress, LLC and Duke Energy Carolinas, LLC - License Amendment Application to Remove Heaters from Ventilation System Technical Specifications ML18130A8072018-05-10010 May 2018 Duke Energy Progress, LLC and Duke Energy Carolinas, LLC - Submittal of License Amendment Application to Remove Heaters from Ventilation System Technical Specifications RA-17-0005, Application to Revise Technical Specifications to Adopt TSTF-545, Revision 3, TS Inservice Testing Program Removal & Clarify SR Usage Rule Application to Section 5.5 Testing2017-11-0707 November 2017 Application to Revise Technical Specifications to Adopt TSTF-545, Revision 3, TS Inservice Testing Program Removal & Clarify SR Usage Rule Application to Section 5.5 Testing RA-17-0045, Supplement: Application to Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules.2017-10-12012 October 2017 Supplement: Application to Revise Technical Specifications to Adopt TSTF-529, Clarify Use and Application Rules. ML17237A0492017-08-17017 August 2017 Technical Specification Bases - List of Effected Sheets ML17237A0482017-08-17017 August 2017 Technical Specification Bases (Rev. 150) ML17237A0462017-08-17017 August 2017 Document Transmittal Form Regarding Technical Specification Changes - Amendment Nos. 296/275 ML17186A0682017-06-26026 June 2017 Tech Spec Bases - List of Affected Sections ML17186A0672017-06-26026 June 2017 Revision 151 to Tech Spec Bases - B 3.6.13 and B 3.6.14 ML17186A0662017-06-26026 June 2017 TS 3.6.13 Amendment 292/271 and TS 3.6.14 Amendment 294/273 ML17186A0692017-06-26026 June 2017 Issue Tech Spec - List of Affected Pages ML17136A2792017-05-0303 May 2017 Technical Specification Leep, Rev. 109 ML17136A2782017-05-0303 May 2017 Technical Specification Bases - Loes, Rev. 133 ML17136A3612017-05-0303 May 2017 Technical Specification Bases, Revision 149 ML17136A3602017-05-0303 May 2017 Technical Specification Amendment Nos. 285/264 ML17124A3682017-04-19019 April 2017 Tech Spec Bases List of Effected Pages ML17124A3712017-04-19019 April 2017 Bases B 3.5.1 - Accumulators ML17094A6722017-03-29029 March 2017 Issue Selected License Commitment Cslcl 16.7.14 Revision ML17094A6732017-03-29029 March 2017 Issue SLC List of Effected Pages ML17090A4522017-03-23023 March 2017 Revision to Technical Specification 3.3.2 - Amendment 293/272 ML17090A4512017-03-23023 March 2017 Revision to Technical Specification 3.8.1 - Amendment 293/272 ML17090A4352017-03-22022 March 2017 Technical Specification Bases ML17090A4502017-03-22022 March 2017 Revision to Technical Specification Bases - B 3.6.15 ML17094A6702017-03-15015 March 2017 Issue MNS-SLC-16.9.15. Snubbers MNS-16-092, License Amendment Request to Revise Technical Specifications Section 5.5.2, Containment Leakage Rate Testing Program for Permanent Extension of Type a and Type C Leak Rate Test Frequencies2016-12-19019 December 2016 License Amendment Request to Revise Technical Specifications Section 5.5.2, Containment Leakage Rate Testing Program for Permanent Extension of Type a and Type C Leak Rate Test Frequencies ML16305A1442016-10-20020 October 2016 Issue MNS Technical Specification 5.5 RA-16-0019, Duke Energy Progress - Application to Revise Technical Specifications to Adopt TSTF-522, Revision 0, Revise Ventilation System Surveillance Requirements to Operate for 10 Hours Per Month Using the Consolidated Line Item Improvement Proces2016-09-27027 September 2016 Duke Energy Progress - Application to Revise Technical Specifications to Adopt TSTF-522, Revision 0, Revise Ventilation System Surveillance Requirements to Operate for 10 Hours Per Month Using the Consolidated Line Item Improvement Process ML16265A5312016-08-30030 August 2016 Issue MNS Tech Spec Bases List of Effective Sections ML16265A5322016-08-30030 August 2016 Technical Specification Bases 3.6.14 Revisions, List of Revisions and Dates ML16250A0142016-08-29029 August 2016 Amendment 287 ML16243A3492016-08-23023 August 2016 Mccguire, Units 1 and 2, Revision 143 to Issue MNS Technical Specification Bases 3.3.1 ML16243A3482016-08-23023 August 2016 Technical Specification 3.3.1, Reactor Trip System (RTS) Instrumentation. ML16243A3512016-08-23023 August 2016 Revision 105 to Technical Specifications List of Effective Pages ML16243A3502016-08-23023 August 2016 Revision 129 to Technical Specification Bases ML16243A3572016-08-18018 August 2016 Technical Specification Bases Revision 001, List of Revised Sections 2023-02-16
[Table view] Category:Amendment
MONTHYEARRA-23-0279, Supplement to Application to Adopt Risk-Informed Completion Times TSTF-505, Revision 2 and Application to Adopt 10 CFR 50.69, Risk-informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power2023-11-0202 November 2023 Supplement to Application to Adopt Risk-Informed Completion Times TSTF-505, Revision 2 and Application to Adopt 10 CFR 50.69, Risk-informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power RA-22-0091, Application to Revise Technical Specifications to Adopt TSTF-554, Revision 1, Revise Reactor Coolant Leakage Requirements2023-02-16016 February 2023 Application to Revise Technical Specifications to Adopt TSTF-554, Revision 1, Revise Reactor Coolant Leakage Requirements RA-18-0190, License Amendment Request to Revise Technical Specifications to Adopt Risk-Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b2023-02-16016 February 2023 License Amendment Request to Revise Technical Specifications to Adopt Risk-Informed Completion Times TSTF-505, Revision 2, Provide Risk-Informed Extended Completion Times - RITSTF Initiative 4b RA-22-0080, Independent Spent Fuel Storage Installation, McGuire, Units 1 & 2, Independent Spent Fuel Storage Installation, Request for an Exemption to the Requirements of Certificate of Compliance No. 1031 for the NAC Magnastor Storage System2022-04-0707 April 2022 Independent Spent Fuel Storage Installation, McGuire, Units 1 & 2, Independent Spent Fuel Storage Installation, Request for an Exemption to the Requirements of Certificate of Compliance No. 1031 for the NAC Magnastor Storage System RA-21-0302, Application to Revise Technical Specifications to Adopt TSTF-569, Rev. 2, Revise Response Time Testing Definition2022-02-24024 February 2022 Application to Revise Technical Specifications to Adopt TSTF-569, Rev. 2, Revise Response Time Testing Definition RA-21-0027, Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections2021-09-16016 September 2021 Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections RA-20-0207, Duke Energy - Application to Revise the Technical Specification for Engineered Safety Feature Actuation System (ESFAS) Instrumentation2020-12-0303 December 2020 Duke Energy - Application to Revise the Technical Specification for Engineered Safety Feature Actuation System (ESFAS) Instrumentation RA-19-0006, License Amendment Application to Relocate Technical Specification Unit/Facility Staff Qualification ANSI N18.1-1971, ANSI/ANS-3.1-1978 and ANSI/ANS-3.1-1981 Requirements to the Duke Energy Corporation Quality Assurance Program Description2019-07-0808 July 2019 License Amendment Application to Relocate Technical Specification Unit/Facility Staff Qualification ANSI N18.1-1971, ANSI/ANS-3.1-1978 and ANSI/ANS-3.1-1981 Requirements to the Duke Energy Corporation Quality Assurance Program Description RA-18-000, Duke Energy Progress, LLC and Duke Energy Carolinas, LLC - Submittal of License Amendment Application to Remove Heaters from Ventilation System Technical Specifications2018-05-10010 May 2018 Duke Energy Progress, LLC and Duke Energy Carolinas, LLC - Submittal of License Amendment Application to Remove Heaters from Ventilation System Technical Specifications ML18130A8072018-05-10010 May 2018 Duke Energy Progress, LLC and Duke Energy Carolinas, LLC - Submittal of License Amendment Application to Remove Heaters from Ventilation System Technical Specifications RA-18-0001, Duke Energy Progress, LLC and Duke Energy Carolinas, LLC - License Amendment Application to Remove Heaters from Ventilation System Technical Specifications2018-05-10010 May 2018 Duke Energy Progress, LLC and Duke Energy Carolinas, LLC - License Amendment Application to Remove Heaters from Ventilation System Technical Specifications RA-17-0005, Application to Revise Technical Specifications to Adopt TSTF-545, Revision 3, TS Inservice Testing Program Removal & Clarify SR Usage Rule Application to Section 5.5 Testing2017-11-0707 November 2017 Application to Revise Technical Specifications to Adopt TSTF-545, Revision 3, TS Inservice Testing Program Removal & Clarify SR Usage Rule Application to Section 5.5 Testing MNS-16-092, License Amendment Request to Revise Technical Specifications Section 5.5.2, Containment Leakage Rate Testing Program for Permanent Extension of Type a and Type C Leak Rate Test Frequencies2016-12-19019 December 2016 License Amendment Request to Revise Technical Specifications Section 5.5.2, Containment Leakage Rate Testing Program for Permanent Extension of Type a and Type C Leak Rate Test Frequencies ML16305A1442016-10-20020 October 2016 Issue MNS Technical Specification 5.5 ML16133A4462016-05-0202 May 2016 Technical Specification 3.7.7, Amendments 282 and 261 ML16133A4692016-05-0202 May 2016 Technical Specification 3.8.1, Amendments 282 and 261 ML16133A4662016-05-0202 May 2016 Technical Specification 3.7.7 - Rev. 140, Amendments 282/261 ML16133A4422016-04-28028 April 2016 Technical Specification 3.5.2, Amendments 282 and 261 ML16133A4432016-04-28028 April 2016 Technical Specification 3.6.6, Amendments 282 and 261 ML16133A4672016-04-28028 April 2016 Technical Specification 3.7.9, Amendments 282 and 261 ML16133A4452016-04-28028 April 2016 Technical Specification 3.7.6, Amendments 282 and 261 ML16133A4442016-04-28028 April 2016 Technical Specification 3.7.5, Amendments 282 and 261 ML16133A4682016-04-28028 April 2016 Technical Specification 3.7.11, Amendment 282/261 MNS-15-069, Duke Energy Carolinas, LLC (Duke Energy), McGuire Nuclear Station, Unit 1 - License Amendment Request for One-Time Change to Technical Specification 3.5.2, Emergency Core Cooling Systems (ECCS) - Operating.2015-08-28028 August 2015 Duke Energy Carolinas, LLC (Duke Energy), McGuire Nuclear Station, Unit 1 - License Amendment Request for One-Time Change to Technical Specification 3.5.2, Emergency Core Cooling Systems (ECCS) - Operating. MNS-14-045, Responses to Request for Additional Information Related to License Amendment Request for One-Time Change to Technical Specification 3.8.4, DC Sources-Operating for Battery Replacement Dated October 28, 20132014-06-0303 June 2014 Responses to Request for Additional Information Related to License Amendment Request for One-Time Change to Technical Specification 3.8.4, DC Sources-Operating for Battery Replacement Dated October 28, 2013 ML13304B4452013-10-28028 October 2013 Revised License Amendment Request for One-Time Change to Technical Specification 3.8.4, DC Sources-Operating for Battery Replacement ML12340A0682012-11-0707 November 2012 Technical Specifications & Tech Spec Bases Updates ML12153A3282012-05-31031 May 2012 Proposed Technical Specifications Amendment TS 3.1.3, Moderator Temperature Coefficient (Mtc) TS 5.6.5, Core Operating Limits Report (COLR) License Amendment Request for Conditional Exemption of the End of Cycle (EOC) Mtc Measurement Method ML11311A1622011-10-31031 October 2011 Technical Specifications & Tech Spec Bases Updates ML1100500792010-12-28028 December 2010 Technical Specifications and Tech Spec Bases Manual Holders ML1026500392010-09-16016 September 2010 License Amendment Request to Revise Technical Specification 5.3, Unit Staff Qualifications ML1019002672010-06-29029 June 2010 License Amendment Request to Revise Reactor Trip System and Engineered Safety Feature Actuation System Technical Specifications ML0928600672009-09-30030 September 2009 Units 1 & 2 and Oconee, Units 1, 2, & 3 - License Amendment Request (LAR) Catawba and McGuire Containment Spray Nozzle and Oconee Reactor Building Spray and Cooling Systems Technical Specification Surveillance Requirement ML0913800922009-05-11011 May 2009 Technical Specification Update ML0911202002009-02-27027 February 2009 Duke Energy Carolinas, LLC - License Amendment Request for Adoption of TSTF-511, Rev. 0, Eliminate Working Hour Restrictions from TS 5.2.2 to Support Compliance with 10 CFR Part 26 ML0829005322008-10-0202 October 2008 Units 1 and 2 - Amendment to Technical Specification 3.6.13, Ice Condenser Doors, Revised Surveillance Requirements ML0804305652008-02-13013 February 2008 Tech Spec Pages for Amendment 244 Regarding Extension of Appendix J, Type a Integrated Leakage Rate Test Interval ML0734804452007-12-11011 December 2007 Units 1 & 2 - Proposed Technical Specification (TS) Amendment to Relax Completion Times and Surveillance Intervals for the Reactor Trip System (RTS) Instrumentation TS 3.3.1, Engineered Safety Feature ML0726301322007-09-18018 September 2007 Corrected Technical Specification Pages Regarding Steam Generator Tube Integrity, TSTF-449, Rev 4 ML0723301182007-08-0909 August 2007 Response to Request for Additional Information Re Proposed Technical Specification (TS) Amendment TS 5.5.2 Containment Leak Rate Testing Program ML0706006602007-03-0101 March 2007 Technical Specification Pages Regarding Steam Generator Tube Integrity ML0706503552007-02-21021 February 2007 Proposed Technical Specification Amendment TS 5.5.2 Containment Leak Rate Testing Program ML0626901092006-09-25025 September 2006 Technical Specifications, Changes to the Updated Final Safety Analysis Report and Emergency Operating Procedures ML0520202062005-07-0707 July 2005 Units 1 & 2 - License Amendment Request Applicable to Technical Specification 3.9.1, Boron Concentration. ML0509701422005-04-0404 April 2005 Tech Spec Pages for Amendments 227, Eliminating Requirements for Hydrogen Recombiners and Hydrogen Monitors Using the Consolidated Line Item Improvement Process ML0509701552005-04-0404 April 2005 Tech Spec Pages for Amendments 209, Eliminating Requirements for Hydrogen Recombiners and Hydrogen Monitors Using the Consolidated Line Item Improvement Process ML0423804812004-08-18018 August 2004 License Amendment Request for Technical Specification 3.3.2, Engineered Safety Features Actuation System Instrumentation ML0409101232004-03-23023 March 2004 Duke Energy Corp License Amendment Request Applicable to Technical Specifications 5.5.7, Reactor Coolant Pump Flywheel Inspection Program, Using the Consolidated Line Item Improvement Process (CLIIP) ML0327604442003-09-29029 September 2003 Technical Specifications Pages, Amendments 217 & 199 ML0321304972003-06-25025 June 2003 Proposed Technical Specifications and Bases Amendment 2.0, Safety Limits; 3.3, Instrumentation; 3.4, Reactor Coolant System; 5.6, Reporting Requirements 2023-02-16
[Table view] |
Text
Reactor Building 3.6.16 3.6 CONTAINMENT SYSTEMS 3.6.16 Reactor Building LCO 3.6.16 The reactor building shall be OPERABLE.
APPLICABILITY: MODES 1, 2,3, and 4.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Reactor building A.1 Restore reactor building to 24 hours1 days <br />0.143 weeks <br />0.0329 months <br /> inoperable. OPERABLE status.
B. Required Action and B.1 Be in MODE 3. 6 hours0.25 days <br />0.0357 weeks <br />0.00822 months <br /> associated Completion Time not met. AND B.2 Be in MODE 5. 36 hours1.5 days <br />0.214 weeks <br />0.0493 months <br /> SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.6.16.1 Verify the door in each access opening is closed, except 31 days I when the access opening is being used for normal transit entry and exit. I (continued)
McGuire Units 1 and 2 3.6.16-1 Amendment Nos. 212/193
Reactor Building 3.6.16 SURVEILLANCE REQUIREMENTS (continued)
SURVEILLANCE FREQUENCY 4
SR 3.6.16.2 Verify each Annulus Ventilation System train produces a 18 months on a pressure equal to or more negative than -0.5 inch water STAGGERED gauge in the annulus within 22 seconds after a start TEST BASIS signal and -3.5 inches water gauge after 48 seconds.
Verifying that upon reaching a negative pressure of -3.5 inches water gauge in the annulus, the system switches into its recirculation mode of operation and that the time required for the annulus pressure to increase to -0.5 inch water gauge is > 278 seconds.
SR 3.6.16.3 Verify reactor building structural integrity by performing a 3 times every 10 visual inspection of the exposed interior and exterior years, coinciding surfaces of the reactor building. with containment visual examinations required by SR 3.6.1.1 McGuire Units 1 and 2 3.6.1 6-2 Amendment Nos. 212/193
Programs and Manuals 5.5 5.0 ADMINISTRATIVE CONTROLS 5.5 Programs and Manuals The following programs shall be established, implemented, and maintained.
5.5.1 Offsite Dose Calculation Manual (ODCM)
The ODCM shall contain the methodology and parameters used in the calculation of offsite doses resulting from radioactive gaseous and liquid effluents, in the calculation of gaseous and liquid effluent monitoring alarm and trip setpoints, and in the conduct of the radiological environmental monitoring program.
Licensee initiated changes to the ODCM:
- a. Shall be documented and records of reviews performed shall be retained.
This documentation shall contain:
- 1. sufficient information to support the change(s) together with the appropriate analyses or evaluations justifying the change(s), and
- 2. a determination that the change(s) do not adversely impact the accuracy or reliability of effluent, dose, or setpoint calculations;
- b. Shall become effective after the approval of the Station Manager; and
- c. Shall be submitted to the NRC in the form of a complete, legible copy of the entire ODCM as a part of or concurrent with the Radioactive Effluent Release Report for the period of the report in which any change in the ODCM was made. Each change shall be identified by markings in the margin of the affected pages, clearly indicating the area of the page that was changed, and shall indicate the date (i.e., month and year) the change was implemented.
5.5.2 Containment Leakage Rate Testinq Proqram A program shall be established to implement the leakage rate testing of the containment as required by 10 CFR 50.54(o) and 10 CFR 50, Appendix J, Option B, as modified by approved exemptions. This program shall be in accordance with the guidelines contained in Regulatory Guide 1.163, "Performance-Based Containment Leak-Test Program," dated September 1995, as modified by the following exceptions:
- a. NEI 94-01 -1995, Section 9.2.3: The first Type A test performed after the May 27,1993 (Unit 1) and August 20, 1993 (Unit 2) Type A test shall be performed no later than May 26, 2008 (Unit 1) and August 19, 2008 (Unit 2), and l McGuire Units 1 and 2 5.5-1 Amendment Nos. 212/193
Programs and Manuals 5.5 5.5 Programs and Manuals (continued)
- b. The containment visual examinations required by Regulatory Position C.3 shall be conducted 3 times every 10 years, including during each shutdown for SR 3.6.11 Type A test, prior to initiating the Type A test.
5.5.2 Containment Leakage Rate Testing Program (continued)
The peak calculated containment internal pressure for the design basis loss of coolant accident, Pa, is 14.8 psig. The containment design pressure is 15 psig.
The maximum allowable containment leakage rate, La, at Pa, shall be 0.3% of containment air weight per day.
Leakage Rate acceptance criteria are:
- a. Containment leakage rate acceptance criterion is < 1.0 La. During the first plant startup following testing in accordance with this program, the leakage rate acceptance criteria are < 0.75 La for Type A tests and < 0.6 La for Type B and Type C tests.
- b. Airlock testing acceptance criteria for the overall airlock leakage rate is s 0.05 La when tested at > Pa. For each door, the leakage rate is < 0.01 La when tested at > 14.8 psig.
The provisions of SR 3.0.3 are applicable to the Containment Leakage Rate Testing Program.
Nothing in these Technical Specifications shall be construed to modify the testing frequencies required by 10CFR50, Appendix J.
5.5.3 Primary Coolant Sources Outside Containment This program provides controls to minimize leakage from those portions of systems outside containment that could contain highly radioactive fluids during a serious transient or accident to levels as low as practicable. The systems include Containment Spray, Safety Injection, Chemical and Volume Control, Nuclear Sampling, RHR, Boron Recycle, Refueling Water, Liquid Waste, and Waste Gas.
The program shall include the following:
- a. Preventive maintenance and periodic visual inspection requirements; and
- b. Integrated leak test requirements for each system at refueling cycle intervals or less.
5.5.4 Deleted McGuire Units 1 and 2 5.5-2 Amendment Nos. 212/193
Reactor Building B 3.6.16 B 3.6 CONTAINMENT SYSTEMS B 3.6.16 Reactor Building BASES BACKGROUND The reactor building is a concrete structure that surrounds the steel containment vessel. Between the containment vessel and the reactor building inner wall is an annular space that collects containment leakage that may occur following a loss of coolant accident (LOCA). This space also allows for periodic inspection of the outer surface of the steel containment vessel.
The Annulus Ventilation System (AVS) establishes a negative pressure in the annulus between the reactor building and the steel containment vessel under post accident conditions. Filters in the system then control the release of radioactive contaminants to the environment. The reactor building is required to be OPERABLE to ensure retention of containment leakage and proper operation of the AVS. To ensure the retention of containment leakage within the reactor building:
- a. The door in each access opening is closed except when the access opening is being used for normal transit entry and exit.
- b. The sealing mechanism associated with each penetration (e.g.,
welds, bellows, or O-rings) is OPERABLE.
APPLICABLE The design basis for reactor building OPERABILITY is a LOCA.
SAFETY ANALYSES Maintaining reactor building OPERABILITY ensures that the release of radioactive material from the containment atmosphere is restricted to those leakage paths and associated leakage rates assumed in the accident analyses.
The reactor building satisfies Criterion 3 of 10 CFR 50.36 (Ref. 1).
LCO Reactor building OPERABILITY must be maintained to ensure proper operation of the AVS and to limit radioactive leakage from the containment to those paths and leakage rates assumed in the accident analyses.
McGuire Units 1 and 2 EB3.6.16-1 Revision No. 40
Reactor Building B 3.6.1 6 BASES APPLICABILITY Maintaining reactor building OPERABILITY prevents leakage of radioactive material from the reactor building. Radioactive material may enter the reactor building from the containment following a LOCA.
Therefore, reactor building OPERABILITY is required in MODES 1, 2, 3, and 4 when a steam line break, LOCA, or rod ejection accident could release radioactive material to the containment atmosphere.
In MODES 5 and 6, the probability and consequences of these events are low due to the Reactor Coolant System temperature and pressure limitations in these MODES. Therefore, reactor building OPERABILITY is not required in MODE 5 or 6.
ACTIONS A.1 In the event reactor building OPERABILITY is not maintained, reactor building OPERABILITY must be restored within 24 hours1 days <br />0.143 weeks <br />0.0329 months <br />. Twenty-four hours is a reasonable Completion Time considering the limited leakage design of containment and the low probability of a Design Basis Accident occurring during this time period.
B.1 and B.2 If the reactor building cannot be restored to OPERABLE status within the required Completion Time, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 6 hours0.25 days <br />0.0357 weeks <br />0.00822 months <br /> and to MODE 5 within 36 hours1.5 days <br />0.214 weeks <br />0.0493 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
SURVEILLANCE SR 3.6.16.1 REQUI REMENTS Maintaining reactor building OPERABILITY requires maintaining the door in each access opening closed, except when the access opening is being used for normal transit entry and exit. The 31 day Frequency of this SR is based on engineering judgment and is considered adequate in view of the other indications of door status that are available.
McGuire Units 1 and 2 B 3.6.16-2 Revision No. 40
Reactor Building B 3.6.16 BASES SURVEILLANCE REQUI REMENTS (continued)
SR 3.6.16.2 The ability of a AVS train to produce the required negative pressure within the required times provides assurance that the building is adequately sealed. The negative pressure prevents leakage from the building, since outside air will be drawn in by the low pressure. The negative pressure must be established within the time limit to ensure that no significant quantity of radioactive material leaks from the reactor building prior to developing the negative pressure.
The AVS trains are tested every 18 months on a STAGGERED TEST BASIS to ensure that in addition to the requirements of LCO 3.6.10,
'Annulus Ventilation System," either AVS train will perform this test. The 18 month Frequency is based on the need to perform this Surveillance under the conditions that apply during a plant outage.
SR 3.6.1 6.3 This SR would give advance indication of gross deterioration of the concrete structural integrity of the reactor building. The Frequency is based on engineering judgment and is the same as that for containment visual inspections performed in accordance with SR 3.6.1.1.
REFERENCES 1. 10 CFR 50.36, Technical Specifications, (c)(2)(ii).