Reliability of Main Steam Safety Valves| ML031220712 |
| Person / Time |
|---|
| Site: |
Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, 05000000, Zimmer, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant, Skagit, Marble Hill, Crane |
|---|
| Issue date: |
07/10/1986 |
|---|
| From: |
Jordan E NRC/IE |
|---|
| To: |
|
|---|
| References |
|---|
| IN-86-056, NUDOCS 8607030267 |
| Download: ML031220712 (3) |
|
Similar Documents at Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Dresden, Davis Besse, Peach Bottom, Browns Ferry, Salem, Oconee, Mcguire, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Saint Lucie, Point Beach, Oyster Creek, Watts Bar, Hope Creek, Grand Gulf, Cooper, Sequoyah, Byron, Pilgrim, Arkansas Nuclear, Braidwood, Susquehanna, Summer, Prairie Island, Columbia, Seabrook, Brunswick, Surry, Limerick, North Anna, Turkey Point, River Bend, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Callaway, Vogtle, Waterford, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Maine Yankee, Quad Cities, Humboldt Bay, La Crosse, Big Rock Point, Rancho Seco, Zion, Midland, Bellefonte, Fort Calhoun, FitzPatrick, McGuire, LaSalle, 05000000, Zimmer, Fort Saint Vrain, Shoreham, Satsop, Trojan, Atlantic Nuclear Power Plant, Skagit, Marble Hill, Crane |
|---|
Category:NRC Information Notice
[Table view]The following query condition could not be considered due to this wiki's restrictions on query size or depth: <code> [[:Beaver Valley]] OR [[:Millstone]] OR [[:Hatch]] OR [[:Monticello]] OR [[:Calvert Cliffs]] OR [[:Dresden]] OR [[:Davis Besse]] OR [[:Peach Bottom]] OR [[:Browns Ferry]] OR [[:Salem]] OR [[:Oconee]] OR [[:Mcguire]] OR [[:Nine Mile Point]] OR [[:Palisades]] OR [[:Palo Verde]] OR [[:Perry]] OR [[:Indian Point]] OR [[:Fermi]] OR [[:Kewaunee]] OR [[:Catawba]] OR [[:Harris]] OR [[:Wolf Creek]] OR [[:Saint Lucie]] OR [[:Point Beach]] OR [[:Oyster Creek]] OR [[:Watts Bar]] OR [[:Hope Creek]] OR [[:Grand Gulf]] OR [[:Cooper]] OR [[:Sequoyah]] OR [[:Byron]] OR [[:Pilgrim]] OR [[:Arkansas Nuclear]] OR [[:Braidwood]] OR [[:Susquehanna]] OR [[:Summer]] OR [[:Prairie Island]] OR [[:Columbia]] OR [[:Seabrook]] OR [[:Brunswick]] OR [[:Surry]] OR [[:Limerick]] OR [[:North Anna]] OR [[:Turkey Point]] OR [[:River Bend]] OR [[:Vermont Yankee]] OR [[:Crystal River]] OR [[:Haddam Neck]] OR [[:Ginna]] OR [[:Diablo Canyon]] OR [[:Callaway]] OR [[:Vogtle]] OR [[:Waterford]] OR [[:Duane Arnold]] OR [[:Farley]] OR [[:Robinson]] OR [[:Clinton]] OR [[:South Texas]] OR [[:San Onofre]] OR [[:Cook]] OR [[:Comanche Peak]] OR [[:Yankee Rowe]] OR [[:Maine Yankee]] OR [[:Quad Cities]] OR [[:Humboldt Bay]] OR [[:La Crosse]] OR [[:Big Rock Point]] OR [[:Rancho Seco]] OR [[:Zion]] OR [[:Midland]] OR [[:Bellefonte]] OR [[:Fort Calhoun]] OR [[:FitzPatrick]] OR [[:McGuire]] OR [[:LaSalle]] OR [[:05000000]] OR [[:Zimmer]] OR [[:Fort Saint Vrain]] OR [[:Shoreham]] OR [[:Satsop]] OR [[:Trojan]] OR [[:Atlantic Nuclear Power Plant]] OR [[:Skagit]] OR [[:Marble Hill]] OR [[:Crane]] </code>. |
SSINS No.: 6835 IN 86-56
UNITED STATES
NUCLEAR REGULATORY COMMISSION
OFFICE OF INSPECTION AND ENFORCEMENT
WASHINGTON, D.C.
20555
July 10, 1986
IE INFORMATION NOTICE NO. 86-56:
Addressees
All pressurized-water reactor facilities holding an operating license or
construction permit.
Purpose
This information notice (IN) is provided as additional notification of NRC's
concern for the reliability of spring-actuated main steam safety valves follow- ing reports of multiple failures during testing and problems during power
operations and scram recovery.
IN 86-05, "Main Steam Safety Valve Test Fail- ures and Ring Setting Adjustments," previously addressed the problem of inade- quate flow capacity of these valves.
It is expected that recipients will review the information for applicability to
their facilities and consider actions, if appropriate, to preclude similar
problems from occurring at their facilities.
However, suggestions contained in
this notice do not constitute NRC requirements; therefore, no specific action
or written response is required.
Description of Circumstances
While researching IN 86-05, the following problems with main steam safety
valves (MSSVs) that had occurred during testing, power operations, or scram
recovery were tabulated from the licensee event report files.
MAIN STEAM SAFETY VALVE PROBLEMS (01/01/81-03/01/86)
PROBLEM
NUMBER
NUMBER
TESTING
POWER
POST-SCRAM
VALVES
PLANTS
(EVENTS)
(EVENTS)
(EVENTS)
FAILURE TO OPEN
13
6
5
0
1 FAILURE TO RECLOSE
15
9
2
1
8 SPURIOUS OPENING
6
4
2
3
1 LEAKING
7
4
1
3
0
SET POINT DRIFT
HIGH
44
10
11
0
1 LOW
97
14
18
3
3 UNSPECIFIED
75
11
14
0
0
8607030267
1; ,
IN 86-56 July 10, 1986 A number of reports have been received concerning events involving MSSVs.
Four
of the more significant reports are summarized in this and the following para- graphs.
At North Anna 2, 8 of 15 valves would not lift at the maximum pressure
available to the testing device at the site (1147 to 1161 psig).
All 15 valves
were subsequently sent to Wyle Laboratories for further testing.
The as-found
setpoints varied from 1105 to 1223 psig compared with the specified 1085 +/- 11 to 1135 +/- 11 psig setpoints.
All valves were refurbished and setpoints were
adjusted to be within technical specification limits (LER 50/339-86/001).
Salem 2 reported one valve leaking during heatup following a refueling outage.
After the spindle nut was backed away from the forked lever, the valve reseated, but later it lifted and did not immediately reseat.
It was gagged shut.
Subsequently two other valves prematurely lifted. They too were gagged shut.
Later, when a fourth valve lifted, it was declared inoperable.
were then tested and reset to the appropriate setpoints.
The licensee was unable
to determine the cause for the setpoint drift (LER 50/311-85-007).
Oconee 2 reported that 2 MSSVs had failed to reseat promptly.
They reseated at
900 psig instead of 1010 psig following a transient that included a reactor
scram (LER 50/270-85/006).
On October 19, 1985, the 16 MSSVs of Calvert Cliffs Unit 2 were tested to check
and, if required, to adjust the relief pressure setpoints.
Unit 2 contains 2
steam generators, each with 8 MSSVs on a steam header.
Eleven of the 16 valves
were determined to be out of specification, with the as-found setpoints between
22 to 69 psi higher than their nominal setpoints, compared with the technical
specification requirement of +/- 10 psi.
The Licensee Event Report is included
in this notice as Attachment 1 to give an example of the problems found during
testing, and because it is an especially thorough treatment of corrective actions
that may be of value to other facilities.
Discussion:
The safety significance of failure of the MSSVs to open on a PWR is a potential
for over-pressurizing the secondary system with a possibility of a loss of its
pressure boundary integrity.
Failure to reclose has led to overcooling tran- sients and lower-than-normal water levels in the steam generator.
Spurious
opening, usually at power, has led to reactor scrams.
Leaking valves tend to
have more problems than properly functioning valves.
Setpoint drift-low may
cause spurious opening of the valves and may interact synergistically with a
steam generator tube rupture to cause relief through the faulted steam genera- tor in the case where the MSSVs on the faulted steam generator have
lower-than-required setpoints.
Setpoint drift-high can cause secondary pres- sure to rise above the American Society of Mechanical Engineers (ASME) Boiler
and Pressure Vessel Code-specified system pressure limit.
IN 86-56 July 10, 1986 No specific action or written response is required by this information notice.
If you have any questions about this matter, please contact the Regional
Administrator of the appropriate regional office or this office.
4wardL. rdan, Di
r
Division 01 Emergency Preparedness
and Engh eering Response
Office of Inspection and Enforcement
Technical Contact:
Mary S. Wegner, IE
(301)492-4511 Attachments:
1. LER 50/312-85/011
2. Recently Issued IE Information Notices
|
|---|
|
| list | - Information Notice 1986-01, Failure of Main Feedwater Check Valves Causes Loss of Feedwater System Integrity and Water-Hammer Damage (6 January 1986, Topic: Feedwater Heater)
- Information Notice 1986-02, Failure of Valve Operator Motor During Environmental Qualification Testing (6 January 1986, Topic: Magnesium Rotor)
- Information Notice 1986-03, Potential Deficiencies in Enviromental Qualification of Limitorque Motor Valve Operator Wiring (14 January 1986)
- Information Notice 1986-04, Transient Due to Loss of Power to Intergrated Control System at a Pressurized Water Reactor Designed by Babcock & Wilcox (31 January 1986)
- Information Notice 1986-05, Main Steam Safety Valve Test Failures and Ring Setting Adjustments (31 January 1986)
- Information Notice 1986-06, Failure of Lifting Rig Attachment, While Lifting Upper Guide Structure at St. Lucie Unit 1 (3 February 1986, Topic: Control of Heavy Loads)
- Information Notice 1986-06, Failure of Lifting Rig Attachment, while Lifting Upper Guide Structure at St. Lucie Unit 1 (3 February 1986)
- Information Notice 1986-07, Lack of Detailed Instruction & Inadequate Observance of Precautions During Maintenance & Testing of Diesel Generator Woodward Governors (3 February 1986, Topic: Overspeed trip, Overspeed)
- Information Notice 1986-08, Licensee Event Report (LER) Format Modification (3 February 1986, Topic: GOTHIC)
- Information Notice 1986-09, Failure of Check & Stop Check Valves Subjected to Low Flow Conditions (3 February 1986)
- Information Notice 1986-10, Degradation of Reactor Coolant System Pressure Boundary Resulting From Boric Acid Corrosion. (5 January 1995, Topic: Boric Acid, Stress corrosion cracking, Seal weld)
- Information Notice 1986-10, Degradation of Reactor Coolant System Pressure Boundary Resulting from Boric Acid Corrosion (5 January 1995, Topic: Boric Acid, Stress corrosion cracking, Seal weld)
- Information Notice 1986-10, Feedwater Line Break (10 November 1988, Topic: Coatings, Anchor Darling)
- Information Notice 1986-11, Anomalous Behavior of Recirculation Loop Flow in Jet Pump BWR Plants (31 December 1986)
- Information Notice 1986-13, Standby Liquid Control Squib Valves Failure to Fire (5 August 1986, Topic: Squib)
- Information Notice 1986-13, Standby Liquid Control System Squib Valves Failure to Fire (21 February 1986, Topic: Squib)
- Information Notice 1986-14, Overspeed Trips of Afw, HPCI & RCIC Turbines (26 August 1991, Topic: Overspeed trip, Overspeed, Restart)
- Information Notice 1986-14, Overspeed Trips of AFW, HPCI & RCIC Turbines (26 August 1991, Topic: Overspeed trip, Overspeed, Restart)
- Information Notice 1986-15, Loss of Offsite Power Caused by Problems in Fiber Optics Systems (10 March 1986, Topic: Squib, Loss of Offsite Power)
- Information Notice 1986-16, Failures to Identify Containment Leakage Due to Inadequate Local Testing of BWR Vacuum Relief System Valves (11 March 1986, Topic: Squib, Local Leak Rate Testing, Integrated leak rate test)
- Information Notice 1986-17, Update of Failure of Automatic Sprinkler System Valves to Operate (24 March 1986, Topic: Squib)
- Information Notice 1986-18, NRC On-Scene Response During a Major Emergency (26 March 1986, Topic: Squib, Backfit)
- Information Notice 1986-19, Reactor Coolant Pump Shaft Failure at Crystal River (21 March 1986, Topic: Squib)
- Information Notice 1986-20, Low-Level Radioactive Waste Scaling Factors, 10 CFR Part 61 (28 March 1986, Topic: Squib)
- Information Notice 1986-21, Recognition of American Society of Mechanical Engineers Accreditation Program for N Stamp Holders (31 March 1986, Topic: Squib)
- Information Notice 1986-22, Underresponse of Radiation Survey Instrument to High Radiation Fields (31 March 1986, Topic: High Radiation Area, Squib)
- Information Notice 1986-23, Excessive Skin Exposures Due to Contamination with Hot Particles (9 April 1986, Topic: Loss of Offsite Power)
- Information Notice 1986-23, Excessive Skin Exposures due to Contamination with Hot Particles (9 April 1986, Topic: Loss of Offsite Power)
- Information Notice 1986-24, Respirator Users Notice: Increased Inspection Frequency for Certain Self-Contained Breathing Apparatus Air Cylinders (11 April 1986, Topic: Hydrostatic)
- Information Notice 1986-25, Traceability and Material Control of Material and Equipment, Particularly Fasteners (11 April 1986)
- Information Notice 1986-26, Potential Problems in Generators Manufactured by Electrical Products Incorporated (17 April 1986)
- Information Notice 1986-27, Access Control at Nuclear Facilities (21 April 1986, Topic: Contraband, Operational convenience)
- Information Notice 1986-28, Telephone Numbers to the NRC Operations Center and Regional Offices (24 April 1986)
- Information Notice 1986-29, Effects of Changing Valve Moter-Operator Switch Settings (25 April 1986)
- Information Notice 1986-30, Design Limitations of Gaseous Effluent Monitoring Systems (29 April 1986)
- Information Notice 1986-31, Unauthorized Transfer and Loss of Control of Industrial Nuclear Gauges (14 July 1986)
- Information Notice 1986-32, Request for Collection of Licensee Radioactivity Measurements Attributed to Chernobyl Nuclear Plant Accident (2 May 1986, Topic: Chernobyl, Potassium iodide)
- Information Notice 1986-33, Information for Licensee Regarding the Chernobyl Nuclear Plant Accident (6 May 1986, Topic: Chernobyl, Potassium iodide)
- Information Notice 1986-34, Improper Assembly, Material Selection, & Test of Valves & their Actuators (13 May 1986)
- Information Notice 1986-34, Improper Assembly, Material Selection, & Test of Valves & Their Actuators (13 May 1986)
- Information Notice 1986-35, Fire in Compressible Material at Dresden Unit 3 (15 May 1986, Topic: Chernobyl, Restart)
- Information Notice 1986-36, Change in NRC Practice Regarding Issuance of Confirming Letters to Principal Contractors (16 May 1986, Topic: Chernobyl)
- Information Notice 1986-37, Degradation of Station Batteries (16 May 1986, Topic: Chernobyl)
- Information Notice 1986-38, Deficient Operator Actions Following Dual Function Valve Failures (20 May 1986, Topic: Chernobyl)
- Information Notice 1986-39, Failures of RHR Pump Motors and Pump Internals (20 May 1986, Topic: Chernobyl)
- Information Notice 1986-40, Degraded Ability to Isolate the Reactor Coolant System from Low-Pressure Coolant Systems in Bwrs (5 June 1986, Topic: Chernobyl)
- Information Notice 1986-40, Degraded Ability to Isolate the Reactor Coolant System from Low-Pressure Coolant Systems in BWRs (5 June 1986, Topic: Chernobyl)
- Information Notice 1986-41, Evaluation of Questionable Exposure Readings of Licensee Personnel Dosimeters (9 June 1986, Topic: Chernobyl)
- Information Notice 1986-42, Improper Maintenance of Radiation Monitoring Systems (9 June 1986, Topic: Temporary Modification, Chernobyl)