L-2003-038, 2002 Annual Reports of Occupational Exposure, and Reactor Coolant Specific Activity Limits

From kanterella
(Redirected from ML030650992)
Jump to navigation Jump to search
2002 Annual Reports of Occupational Exposure, and Reactor Coolant Specific Activity Limits
ML030650992
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 02/21/2003
From: Jefferson W
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2003-038
Download: ML030650992 (2)


Text

FPL FEB 2 1 ZO3 L-2003-038 10 CFR 50.36 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555 Re: Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 2002 Annual Reports of Occupational Exposure, and Reactor Coolant Specific Activity Limits Attached is a tabulation of the 2002 occupational exposure data for Turkey Point Units 3 and 4 as required by Technical Specification 6.9.1.2.a. Deep dose equivalent exposure by Direct Reading Dosimeter (DRD) was 78.419 person-rem. Deep dose equivalent exposure by Thermoluminescent Dosimeter (TLD) was 73.565 person-rem. Deep dose equivalent exposure by TLD includes conservative application of dose due to lost or damaged dosimetry and neutron exposure.

In accordance with Technical Specification 6.9.1.2.b, the reactor coolant specific activity limits of 100/E-bar microcuries per gram of gross radioactivity, and 1.0 microcurie per gram Dose Equivalent 1-131 defined by Technical Specification 3.4.8 for Units 3 and 4, were not exceeded during 2002.

Should there be any questions regarding this information, please contact us.

Ve truly

/you William Jefferson, Jr.

Vice President Turkey Point Plant DRL Attachment NRC Regulatory Issue Summary 2001-05 waived the requirements that multiple copies of documents be submitted to the NRC.

an FPL Group company

Feb 11, 2003 FLORIDA POWER & LIGHT COMPANY TURKEY POINT NUCLEAR STATION Regulatory Guide 1.16 Information End of Year Person-rem Report 2002 Number of Personnel

> 100 mrem Total 12 person-rem 2 2 11 Station Utility Contractor Station' Utilityl Contractor Work and Job Function ROUTINE OPERATIONS AND SURVEILLANCE MAINTENANCE AND CONSTRUCTION 0 0 0 0.933 0.079 0.814 OPERATIONS 1 0 0 0.624 0.000 0.000 HEALTH PHYSICS 7 0 14 1.028 0.101 2.067 SUPERVISORY 0 0 0 0.079 0.001 0.108 ENGINEERING 0 0 0 0.359 0.092 0.197 ROUTINE PLANT MAINTENANCE MAINTENANCE AND CONSTRUCTION 39 8 126 7.091 0.787 21.178 OPERATIONS 4 0 1 3.173 0.000 0.186 HEALTH PHYSICS 12 0 9 4.302 0.002 3.099 SUPERVISORY 0 0 3 0.602 0.096 0.719 ENGINEERING 3 1 3 1.161 0.428 0.841 INSERVICE INSPECTION MAINTENANCE AND CONSTRUCTION 0 0 0 0.036 0.000 1.282 OPERATIONS 0 0 0 0.000 0.000 0.000 HEALTH PHYSICS 0 0 0 0.000 0.000 0.000 SUPERVISORY 0 0 0 0.000 0.003 0.000 ENGINEERING 0 0 0 0.052 0.017 0.703 SPECIAL PLANT MAINTENANCE MAINTENANCE AND CONSTRUCTION 0 0 6 0.306 0.012 3.177 OPERATIONS 0 0 0 0.005 0.000 0.000 HEALTH PHYSICS 0 0 0 0.151 0.000 0.000 SUPERVISORY 0 0 0 0.000 0.003 0.000 ENGINEERING 0 0 0 0.063 0.003 0.000 WASTE PROCESSING MAINTENANCE AND CONSTRUCTION 0 0 0 0.230 0.000 0.000 OPERATIONS 0 0 0 0.017 0.000 0.256 HEALTH PHYSICS 0 0 0 0.492 0.000 0.000 SUPERVISORY 0 0 0 0.000 0.000 0.000 ENGINEERING 0 0 0 0.000 0.000 0.000 REFUELING MAINTENANCE AND CONSTRUCTION 0 0 0 2.107 1.813 11.736 OPERATIONS 0 0 0 0.918 0.000 0.000 HEALTH PHYSICS 0 0 0 0.637 0.001 2.530 SUPERVISORY 0 0 0 0.489 0.061 0.005 ENGINEERING 0 0 0 0.870 0.155 0.142 Totals MAINTENANCE AND CONSTRUCTION 39 8 132 10.703 2.691 38.187 OPERATIONS 5 0 1 4.737 0.000 0.442 HEALTH PHYSICS 19 0 23 6.610 0.104 7.696 SUPERVISORY 0 0 3 1.170 0.164 0.832 ENGINEERING 3 1 3 2.505 0.695 1.883 Grand Totals 66 9 162 25.725 3.654 49.040

[" PERSON-REM VALUES IN THE TABLE ARE MEASURED BY ELECTRONIC DOSIMETERS TOTAL STATION EXPOSURE (DDE) BY TLD: 73.565