Information Notice 2002-29, (Errata): Recent Design Problems in Safety Functions of Pneumatic Systems

From kanterella
(Redirected from ML023110005)
Jump to navigation Jump to search
(Errata): Recent Design Problems in Safety Functions of Pneumatic Systems
ML023110005
Person / Time
Issue date: 11/06/2002
From: Beckner W
NRC/NRR/DRIP/RORP
To:
Hodge, CV, NRR/DRIP/RORP, (415-1861)
References
IN-02-029, ERR
Download: ML023110005 (4)


UNITED STATES

NUCLEAR REGULATORY COMMISSION

OFFICE OF NUCLEAR REACTOR REGULATION

WASHINGTON, D.C. 20555-0001

November 6, 2002

NRC INFORMATION NOTICE 2002-29 (ERRATA):

RECENT DESIGN PROBLEMS IN

SAFETY FUNCTIONS OF PNEUMATIC

SYSTEMS

Addressees

All holders of operating licenses or construction permits for nuclear power reactors.

Discussion

A typographical error has been identified in Information Notice 2002-29, Recent Design

Problems in Safety Functions of Pneumatic Systems, issued on October 15, 2002. The Event

Notification number of the event report submitted by the San Onofre licensee is incorrectly

given as 36980; the correct number is 36960.

If you have any questions about this matter, contact the staff member listed below or the

appropriate Office of Nuclear Reactor Regulation (NRR) project manager.

/RA/

William D. Beckner, Program Director

Operating Reactor Improvements Program

Division of Regulatory Improvement Programs

Office of Nuclear Reactor Regulation

Technical contact: V. Hodge, NRR

301-415-1861 E-mail: cvh@nrc.gov

Attachment: List of Recently Issued NRC Information Notices

ML023110005

UNITED STATES

NUCLEAR REGULATORY COMMISSION

OFFICE OF NUCLEAR REACTOR REGULATION

WASHINGTON, D.C. 20555-0001

November 6, 2002

NRC INFORMATION NOTICE 2002-29 (ERRATA):

RECENT DESIGN PROBLEMS IN

SAFETY FUNCTIONS OF PNEUMATIC

SYSTEMS

Addressees

All holders of operating licenses or construction permits for nuclear power reactors.

Discussion

A typographical error has been identified in Information Notice 2002-29, Recent Design

Problems in Safety Functions of Pneumatic Systems, issued on October 15, 2002. The Event

Notification number of the event report submitted by the San Onofre licensee is incorrectly

given as 36980; the correct number is 36960.

If you have any questions about this matter, contact the staff member listed below or the

appropriate Office of Nuclear Reactor Regulation (NRR) project manager.

/RA/

William D. Beckner, Program Director

Operating Reactor Improvements Program

Division of Regulatory Improvement Programs

Office of Nuclear Reactor Regulation

Technical contact: V. Hodge, NRR

301-415-1861 E-mail: cvh@nrc.gov

Attachment: List of Recently Issued NRC Information Notices

ML023110005 DISTRIBUTION:

ADAMS

IN File

DOCUMENT NAME: G:\\RORP\\OES\\STAFF FOLDERS\\Shapaker\\1101-Hodge-errata-jws.wpd

OFFICE

SC:EEIB:DE

SC:RORP:DRIP PD:RORP:DRIP

NAME

JWShapaker

TReis

WDBeckner

DATE

11/05/2002

11/ /2002

11/06/2002

OFFICIAL RECORD COPY

______________________________________________________________________________________

OL = Operating License

CP = Construction Permit

Attachment

IN 2002-29 (Errata) LIST OF RECENTLY ISSUED

NRC INFORMATION NOTICES

_____________________________________________________________________________________

Information

Date of

Notice No.

Subject

Issuance

Issued to

_____________________________________________________________________________________

2002-32

Electromigration on

Semiconductor Integrated

Circuits

10/31/2002

All holders of operating licenses

for nuclear power reactors except

those who have ceased

operations and have certified that

fuel has been permanently

removed from the reactor vessel.

2002-31

Potentially Defective UF6

Cylinder Valves (1-inch)

10/31/2002

All licensees authorized to

possess and use source material

and/or special nuclear material for

the heating, emptying, filling, or

shipping of uranium hexafluoride

(UF6) in 30- and 48-inch

cylinders.

2002-30

Control and Surveillance of

Portable Gauges During Field

Operations

10/30/2002

All NRC licensees authorized to

possess, use, transport, and store

portable gauges.

2002-29

Recent Design Problems in

Safety Functions of Pneumatic

Systems

10/15/2002

All holders of operating licenses

or construction permits for

nuclear power reactors.

2002-28

Appointment of Radiation

Safety Officers and Authorized

Users Under 10 CFR Part 35

09/27/2002 All medical licensees.

2002-27

Recent Fires at Commercial

Nuclear Power Plants in the

United States

09/20/2002

All holders of operating licenses

for nuclear power reactors, except those who have

permanently ceased operations

and have certified that fuel has

been permanently removed from

the reactor.

Note:

NRC generic communications may be received in electronic format shortly after they are

issued by subscribing to the NRC listserver as follows:

To subscribe send an e-mail to <listproc@nrc.gov >, no subject, and the following

command in the message portion:

subscribe gc-nrr firstname lastname