L-2014-053, St. Lucie, Units 1 and 2 - 2013 Annual Radioactive Effluent Release Report
ML14069A121 | |
Person / Time | |
---|---|
Site: | Saint Lucie ![]() |
Issue date: | 02/28/2014 |
From: | Katzman E S Florida Power & Light Co |
To: | Document Control Desk, Office of Nuclear Reactor Regulation |
References | |
L-2014-053 | |
Download: ML14069A121 (57) | |
Text
0 FPL. February 28, 2014 L-2014-053 10 CFR 50.36 10 CFR 50.36a U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re: St. Lucie Units I and 2 Docket Nos. 50-335 and 50-389 2013 Annual Radioactive Effluent Release Report Pursuant to 10 CFR 50.36a(a)(2) and Technical Specification (TS) 6.9.1.7, enclosed is the 2013 Annual Radioactive Effluent Release Report for St. Lucie Units 1 and 2. The report provides information for the 12-month period beginning January 1, 2013 and ending December 31, 2013.Enclosure I includes the Combined Annual Radioactive Effluent Release Report.Enclosure 2 is a copy of C-200, Offsite Dose Calculation Manual (ODCM), Revision 41.Enclosure 3 is a copy of the marked up pages from Revisions 39, 40 and 41 of the ODCM.Please contact us with any questions regarding this submittal.
Sincerely, Eric S. Katzman Licensing Manager St. Lucie Plant ESK/tlt Enclosures Florida Power & Light Company 6501 S. Ocean Drive, Jensen Beach, FL 34957 FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS 1 AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2013 THROUGH DECEMBER 31, 2013 1.0 PROGRAM DESCRIPTION 2.0 SUPPLEMENTAL INFORMATION 2.1 Abnormal Releases or Abnormal Discharges 2.2 Non-Routine Planned Discharges 2.3 Radioactive Waste Treatment System Changes 2.4 Annual Land Use Census Changes 2.5 Effluent Monitoring System Inoperability 2.6 Offsite Dose Calculation Manual Changes 2.7 Process Control Program Changes 2.8 Corrections to Previous Reports 2.9 Other 2.10 Groundwater Protection Program 3.0 TABLES 3.1 Gaseous Effluents
& Liquid Effluents 3.2 Solid Waste Storage and Shipments 3.3 Dose Assessments 3.4 Visitor Dose FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS 1 AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2013 THROUGH DECEMBER 31, 2013 1.0 PROGRAM DESCRIPTION Regulatory Limits The ODCM Radiological Effluent Control limits applicable to the release of radioactive material in liquid and gaseous effluents are described in the following sections.Fission and Activation Gases (Noble Gases)The dose rate due to radioactive materials released in gaseous effluents from the site to areas at and beyond the site boundary shall be limited to less than or equal to 500 mrems/yr to the whole body and less than or equal to 3000 mrems/yr to the skin.The air dose due to noble gases released in gaseous effluents, from each unit, to areas at and beyond the site boundary shall be limited to the following:
- a. During any calendar quarter: Less than or equal to 5 mrads for gamma radiation and less thah or equal to 10 mrads for beta radiation, and b. During any calendar year: Less than or equal to 10 mrads for gamma radiation and less than or equal to 20 mrads for beta radiation.
Iodine-131, Iodine-133, Tritium, Carbon-14 and Radioactive Material in Particulate Form The dose rate due to iodine-131, iodine-133, tritium and all radionuclides in particulate form with half lives greater than 8 days, released in gaseous effluents from the site to areas at and beyond the site boundary, shall be limited to less than or equal to 1500 mrem/yr to any organ.The dose to a MEMBER OF tHE PUBLIC from iodine-131, iodine-133, tritium, carbon-14 and all radionuclides in particulate form with half lives greater than 8 days, in gaseous effluents released, from each unit, to areas at and beyond the site boundary, shall be limited to the following:
- a. During any calendar quarter: Less than or equal to 7.5 mrems to any organ, and b. During any calendar year: Less than or equal to 15 mrems to any organ.
FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS 1 AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2013 THROUGH DECEMBER 31, 2013 Liquid Effluents The concentration of radioactive material released in liquid effluents to unrestricted areas shall be limited to 10 times the concentrations specified in 10 CFR Part 20, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases. For dissolved or entrained noble gases, the concentration shall be limited to 2.0E-4 pCi/ml total activity.The dose or dose commitment to a MEMBER OF THE PUBLIC from radioactive materials in liquid effluents released, from each unit, to unrestricted areas shall be limited: a. During any calendar quarter to less than or equal to 1.5 mrems to the whole body and to less than or equal to 5 mrems to any organ, and b. During any calendar year to less than or equal to 3 mrems to the whole body and to less than or equal to 10 mrems to any organ.Total Dose The annual (calendar year) dose or dose commitment to any MEMBER OF THE PUBLIC due to releases of radioactivity and to radiation from uranium fuel cycle sources shall be limited to less than or equal to 25 mrems to the whole body or any organ, except the thyroid, which shall be limited to less than or equal to 75 mrems.Effluent Concentration Limits Gaseous Effluents For gaseous effluents, effluent concentration limits (ECL) values are not directly used in release rate calculations since the applicable limits are expressed in terms of dose rate at the site boundary.Liquid Effluents The values specified in 10 CFR Part 20, Appendix B, Table 2, Column 2 are used as the ECL for liquid radioactive effluents released to unrestricted areas. A value of 2.OE-04 pCi/ml is used as the ECL for dissolved and entrained noble gases in liquid effluents.
Measurements and Approximations of Total Radioactivity Measurements of total radioactivity in liquid and gaseous radioactive effluents were accomplished in accordance with the sampling and analysis requirements of Tables 4.11-1 and 4.11-2, respectively, of the St. Lucie ODCM. Estimates of errors are in accordance with Methodology Section 4.4, of the ODCM.
FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS 1 AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2013 THROUGH DECEMBER 31, 2013 The estimate of errors associated with values reported is as follows: LIQUID GASEOUS Error Topic Avg. % Max. % Avg. % Max. %Release Point Mixing 2 5 NA NA Sampling 1 5 2 5 Sample Preparation I 5 1 5 Sample Analysis 3 10 3 10 Release Volume 2 5 4 15 Total % 9 30 10 35 (above values are examples only)The predictability of error for radioactive releases can only be applied to nuclides that are predominant in sample spectrums.
Nuclides that are near background relative to the predominant nuclides in a given sample could easily have errors greater than the above listed maximums.Liquid Radioactive Effluents Each batch release was sampled and analyzed for gamma emitting radionuclides using gamma spectroscopy, prior to release. Composite samples were analyzed monthly for tritium and gross alpha radioactivity in the onsite laboratory using liquid scintillation and air ion chamber counting techniques, respectively.
Composite samples were analyzed quarterly for Sr-89, Sr-90, Fe-55, Ni-63 and C-14 by a contract laboratory.
The results of the composite analyses from the previous month or quarter were used to estimate the quantities of these radionuclides in liquid effluents during the current month or quarter.The total radioactivity in liquid effluent releases was determined from the measured and estimated concentrations of each radionuclide present and the total volume of the effluent released during periods of discharge.
Gaseous Radioactive Effluents Each gaseous batch, was sampled and analyzed for radioactivity prior to release. For releases from Gas Decay Tanks, noble gas grab samples were analyzed for gamma emitting radionuclides using gamma spectroscopy.
For releases from the Containment Buildings, samples were taken of noble gas and tritium grab samples, and analyzed for gamma emitting radionuclides prior to each release. The results of the analyses and the total volume of effluent released were used to determine the total amount of radioactivity released in the batch mode.
FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS 1 AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2013 THROUGH DECEMBER 31, 2013 For continuous effluent release pathways, noble gas and tritium grab samples were collected and analyzed weekly for gamma emitting radionuclides by gamma spectroscopy and liquid scintillation counting techniques, respectively.
Continuous release pathways were continuously sampled using radioiodine adsorbers and particulate filters. The radioiodine adsorbers and particulate filters were analyzed weekly for gamma emitting radionuclides using gamma spectroscopy.
Results of the noble gas and tritium grab samples, radioiodine adsorber and particulate filter analyses from the current week and the average effluent flow rate for the previous week were used to determine the total amount of radioactivity released in the continuous mode. Monthly composites of particulate filters were analyzed for gross alpha activity, in the onsite laboratory using the air ion chamber counting technique.
Quarterly composites of particulate filters were analyzed for Sr-89 and Sr-90 by a contract laboratory.
Meteorological Monitoring Program In accordance with ODCM Administrative Control 3.11.2.6.b., a summary of hourly meteorological data, collected during 2013, is retained onsite.This data is available for review by the NRC upon request. During 2013, the goal of >90% joint data recovery was met. Actual meteorological data collected during the year was used for the offsite dose calculations in this report.Carbon-14 Dose Estimation The estimate of carbon-14 (C-14) released from the St. Lucie Nuclear Plant was derived from the EPRI document, "Estimation of Carbon-14 in Nuclear Power Plant Gaseous Effluents", Report 1021106, issued December 2010.The site specific source term values used in the St. Lucie calculations were taken from Section 4-28 of the report, and employed the proxy generation rate values for a Combustion Engineering reactor. The actual 2013 operating data for the units was employed for the calculations to derive the total curies released for each unit.The total amount of C-14 released in 2013 for Unit I was 9.17 Ci, and the total amount of C-14 released in 2013 for Unit 2 was 11.32 Ci. The highest calculated dose is found to be "Bone Dose" to a "Child" through"Inhalation".
The total combined dose from C-14 through this pathway is 1.55E-01 mrem/yr.
FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS 1 AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2013 THROUGH DECEMBER 31, 2013 Additionally, a "Child" consuming vegetables from the garden located at 2.0 miles in the WSW direction from the plant would have received a total combined "Bone Dose", including C-14, of 1.55E-1 mrem/yr.Using the same release values, the dose to a visitor on site (Adult Lifeguard) is found to be 4.17E-01 mrem/yr, Total Body dose.All C-14 dose calculations are based on Regulatory Guide 1.109 values.This is a fraction of the I mrem annual whole body dose received by the average US citizen from natural occurring Carbon-14, primarily generated through cosmogenesis in the terrestrial biosphere. (Reference National Council of Radiation Protection Report 45, Natural Background Radiation in the United States.)2.0 SUPPLEMENTAL INFORMATION 2.1 Abnormal Releases or Abnormal Discharges There were no abnormal (unplanned) releases or discharges from the site during the report period.2.2 Non-Routine Planned Discharges No non-routine planned discharges were made during the report period.2.3 Radioactive Waste Treatment System Changes No changes were made to thewaste treatment system during the report period.2.4 Annual Land Use Census Changes There were two changes to the Land Use Census during 2013. Two gardens located in the West Northwest (WNW) sector at 4.0 and 4.2 miles from the plant site were identified during the Land Use Census. The garden located 4.0 miles from the plant is approximately 25' x 30' and grows sweet potatoes, lettuce, cabbage and greens. The garden located 4.2 miles from the plant is approximately 15' x 50' and grows tomatoes, lettuce and cabbage.2.5 Effluent Monitoring System Inoperability There were no effluent monitors out of service for greater than 30 days.
FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS 1 AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2013 THROUGH DECEMBER 31, 2013 2.6 Offsite Dose Calculation Manual Changes Three revisions were made to the St. Lucie ODCM during the report period. The first revision was an administrative change to clarify the sample collection frequency for crustacean, fish and broad leaf vegetation.
The second and third revisions were to update procedure reference numbers, and did not change the intent of the procedure.
2.7 Process Control Program Changes There were no changes to the Process Control Program during the report period.2.8 Corrections to Previous Reports None 2.9 Other Six batch releases were made from the South Settling Basin to the Intake Canal during the year to lower the water level from periods of higher than normal rainfall.
All six releases were analyzed according to the ODCM and site procedural requirements and were found to have no alpha, gamma, tritium or hard to detect isotopes.
The releases are listed below: Release start date Volume of release May 23 3.24E4 gallons June 6 3.30E6 gallons September 12 3.19E6 gallons September 24 1.42E6 gallons November 21 9.09E6 gallons December 6 3.19E6 gallons 2.10 Groundwater Protection Program (next 2 pages) 2013 PSL Ground Water Well Results for Annual Report H3 Jan H3 Feb H3 Mar H3 Apr H3 May H3 June H3 July H3 Aug H3 Sept H3 OCT H3 NOV H3 Dec 2013 2013 2013 2013 2013 2013 2013 2013 2013 2013 2013 2013 L tU pCill pCi/I pCi/I pC i/I pCi/I pCill pCill pCi/I pCill pCi/I pCi/I pCi/I MW-3 633 392 524 681 MW-4 .635 482 423 370 540 798 711 MW-5 <MDC <MDC <MDC <MDC MW-6 1710 1690 1830 1920 1520 1640 1450 MW-7 <MDC <MDC <MDC 283 MW-15 3050 1220 923 571 517 MW-16 285 300 414 .347 MW-17 1110 1060 1230 2000 833 1680 726 MW-18D 1400 1900 1350 1120 1010 832 688 MW-19 <MDC <MDC <MDC <MDC MW-22D <MDC 459 403 213 MW-26 <MDC <MDC <MDC <MDC RW-2 392 498 440 272 419 201 338 RW-4 <MDC <MDC .<MDC <MDC <MDC RW-5 <MDC <MDC <MDC <MDC MW-30 427 290
- 362 328 MW-31 257 369 389 488 MW-32 315 256 381 392 MW-33 q 1100 1210 1130 1420 1030 1540 1410 H3 --- --H3 Jan H3 Feb H3 Mar H3 Apr H3 May H3 July H3 Aug H3 Sept H3 OCT H3 NOV H3 Dec Monitor Well ID 2013 2013 2013 2013 2013 June2Ol 2013 2013 2013 2013 2013 2013 3 L s pCiI pCill pCill pCi/I pCi/I pCi/I pCill pCi/I pCi/I pCill pCi/I pCi/I Unit 1-MWO01 557 468 302 <MDC 214 250 <MDC Unit 1-MWO02 722 358 341 193 316 300 212 Unit 1-MWO03 176 <MDC <MDC 230 Unit 1-MWO04 368 428 506 290 Unit 1-MWO05 822 789 2670 3080 1050 1210 539 Unit 2-MWO01 924 1200 1520 616 651 725 <MDC Unit 2-MWO02 <MDC <MDC 522 553 885 632 Unit 2-MWO03 506 417 607 538 446 461 689 Unit 2-MWO04 727 728 813 869 752 962 759 2013 PSL Ground Water Well Results for Annual Report H3 Jan H3 Feb H3 Mar H3 Apr H3 May H3 July H3 Aug H3 Sept H3 OCT H3 NOV H3 Dec Monitor Well ID 2013 2013 2013 2013 2013 June2Ol 2013 2013 2013 2013 2013 2013 3ý J =p i I p i I ~ a p i I ~ l p C i/I I p C i/ I p C i/I J p C i/I p C i ll p C i/Ip i/(S)-MW-1 <MDC <MDC I <MDC I <MDC p (S)-MW-2 Inactive Well (S)-MW-3 Inactive Well (S)-MW-4 I 4491 I I 4891 I I 4461 I I 4261 (S)-MW-5 Inactive Well (S)-MW-6 4141 I 3211 1 I 2701 1891 (S)-MW-7A I <MDC MDC MDCI I <MDCI (S)-MW-10 Inactive Well (S)-MW-il I 3521 I I 2991 I I 3981 I I 1971 (S)-MW-13D Inactive Well (S)-MW-14 Inactive Well (S)-MW-15D
<MDC <MDC <MDC <MDC (S)-MW-16
<MDC <MDC <MDC <MDC (S)-MW-16i
<MDC <MDC <MDC 289 (S)-MW-17
<MDC <MDC <MDC <MDC (S)-MW-18
<MDC <MDC 255 <MDC (S)-MW-19
<MDCI <MDCi <MDCi 304 H3 Jan H3 Feb H3 Mar H3 Apr H3 May H3 H3 July H3 Aug H3 Sept H3 OCT H3 NOV H3 Dec Monitor Well ID June201 2013 2013 2013 2013 2013 3 2013 2013 2013 2013 2013 2013...I a i pCi/I pCi/I pCi/I pCi/I pCi/I pCi/I pCi/I pCi/I pCi/I pCi l pCi/I pCi/I PSLED -2 <MDC NB-MW-1 239 NB-MW-2 <MDC FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS 1 AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2013 THROUGH DECEMBER 31, 2013 3.0 TABLES 3.1 Gaseous Effluents
& Liquid Effluents (Enclosure 1, 24 pages)3.2 Solid Waste Storage and Shipments (Enclosure 1, 6 pages)3.3 Dose Assessments (Enclosure 1, 15 pages)3.4 Visitor Dose (Enclosure 1, 1 page)
SEf MSur N Sofm-arv Monday, February 17, 2014 1:51:52PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 5A and 5B -Liquid and Gas Batch Release Summary A. Liquid Batch Release Totals 1. Number of Batch Releases 2. Total duration of batch releases 3. Maximum batch release duration 4. Average batch release duration 5. Minimum batch release duration B. Gas Batch Release Totals 1. Number of Batch Releases 2. Total duration of batch releases 3. Maximum batch release duration 4. Average batch release duration 5. Minimum batch release duration Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Units 1st Quarter 2nd Quarter 3rd Quarter 7 14 19 min 4.17E+03 8.12E+03 1.06E+04 min 7.1OE+02 1.44E+03 8.75E+02 min 5.96E+02 5.80E+02 5.59E+02 min 5.05E+02 3.60E+02 2.95E+02 Units 1st Quarter 2nd Quarter 3rd Quarter 61 62 57 min 1.20E+04 1.34E+04 1.29E+04 min 4.78E+02 7.47E+02 6.77E+02 min 1.96E+02 2.16E+02 2.27E-+02 min 1.50E+01 1.70E+01 1.20E+01 4th Quarter 37 2.91E+04 2.29E+03 7.86E+02 4.20E+02 4th Quarter 48 1.13E+04 7.20E+02 2.36E+02 1.OOE+01 Year Totals 77 5.20E+04 2.29E+03 6.75E+02 2.95E+02 Year Totals 228 4.96E+04 7.47E+02 2.18E+02 1.OOE+01 User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP EJ.. l. E II .'S' Monday, February 17 F Reg. Guide 1.21, Table 6A and 6B -Liquid and Gas Abnormal Release Summary Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 A. Liquid Abnormal Release Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter 1. Number of Abnormal Releases 0 0 0 0 2. Total Activity of abnormal releases Ci O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 B. Gas Abnormal Release Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter 1. Number of Abnormal Releases 0 0 0 0 2. Total Activity of abnormal releases Ci 0.OOE+00 0.00E+00 O.00E+00 O.00E+00 , 2014 1:54:35PM lorida Power & Ught t. Lucie Power Plant Year Totals 0 0.OOE+00 Year Totals 0 0.00E+00 User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP EMS Page 1 of 1 Monday, February 17, 2014 1:56:56PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 1A, Gaseous Effluents
-Summation of All Releases Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Total Release A. Fission and Activation Gases 1. Total Release 2. Average Release Rate for Period 3. Percent of Limit B. Iodines and Halogens 1. Total Release 2. Average Release Rate for Period.3. Percent of Limit C. Particulates
- 1. Total Release 2. Average Release Rate for Period 3. Percent of Limit D. Tritium 1. Total Release 2. Average Release Rate for Period 3. Percent of Limit E. Gross Alpha 1. Total Release F. Carbon-14 1. Total Release 2. Average Release Rate for Period 3. Percent of Limit Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Uncertainty Ci uCVs Ci uCi/s Ci uCi/s Ci uCi/s Ci Ci uCi/s 2. 10E+00 2.70E-01 0.OOE+00 O.OOE+00 0.OOE-i00 0.OOE+00 1.73E+01 2.23E+00 1.14E-07 5.04E+00 6.49E-01 3.17E+00 4.03E-01 1.65E-08 2.09E-09 0.OCE+00 0.OOE+00 1.O1E+01 1.29E+00 5.28E-09 5.55E+00 7.06E-01 1.10E+00 1.39E-01 0.QOE+00 O.OOE+00 O.OOE+00 0.OOE+O0 6.35E-01 7.99E-02 1 .37E-07 5.79E+00 7.28E-01 8.57E-01 1 .08E-01 1.73E-05 2. 17E-06 1.43E-06 1.80E-07 8.71E+00 1.1OE+00 2.97E-08 4.07E+00 5. 12E-01 7.23E+00 1.29E-01 1.73E-05 5.48E-07 1.43E-06 4.53E-08 3.68E+i01 1.17E+00 2.86E-07 2.05E+01 6.48E-01 User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP WEMS Page 1 of 3 Monday, February 17, 2014 1:57:48PM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 1B, Gaseous Effluents
-Ground Level Release -Continuous Mode Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Continuous Mode Nuclides Released A. Fission and Activation Gases Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Xe-131m Xe-133 Xe-135 Total For Period B. lodines and Halogens 1-131 1-133 Total For Period C. Particulates Co-60 D. Tritium H-3 E. Gross Alpha G-Alpha F. Carbon-14 C-14 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 0.OOE+O0 1.60E+00 0.OOE+LJO 1.60E+00 0.OOE+00 O.OOE+00 O.OOE+OO O.OOE+00 1.72E+01 1.14E-07 5.04E+00 2.48E+00 0.OOE+O0 7.58E-02 2.56E+00 1 .65E-08 0,OOE+00 1.65E-08 0.QOE+00 9.97E+00 5.28E-09 5.55E+00 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+0O 0.OOE+00 0.OOE+00 O.OOE+OO 0.OOE+00 O.OOE+QO 1.37E-07 5.79E+00 0.OOE+00 0.OOE+00 0.OOE+O0 O.OOE+OO 5.95E-06 1.13E-05 1.73E-05 1 .43E-06 8.65E+00 2.97E-08 4.07E+00 Annual 2.48E+00 1.60E+00 7.58E-02 4.16E+00 5.96E-06 1.13E-05 1.73E-05 1.43E-06 3.58E+01 2.86E-07 2.05E+01 Ci If Not Detected, Nuclide is Not Reported.
Zeroes in this table indicates that no radioactivity was present at detectable levels.User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Florida Power & Light, St. Lucie Power Plant 2/17/2014 13:57 Page 2 of 3 Reg. Guide 1.21, Table 1B, Gaseous Effluents
-Ground Level Release -Batch Mode Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released A. Fission and Activation Gases Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 Total For Period B. lodines and Halogens No Nuclides Found Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 4.07E-01 3.91E-05 2.61E-02 1.37E-04 0.OOE+00 6.52E-04 2.69E-03 4.97 E-02 9.28E-04 3.39E-03 9.42E-03 Q.OOE+Q0 5.001E-01 4.97E-01 2. 18E-04 0.OOE+00 6.29E-04 6.98E-05 1.81E-04 3.66E-0J4 6.98E-02 1.65E-04 1 .74E-02 2.83E-02 5.87E-04 6.14E-01 5.13E-01 0.OOE+00 0.00E+00 3.57E-05 0.OOE+00 0.OOE+00 0.QOE+00 5.60E-01 0.OOE--00 2.89E-02 0.OOE+00 0.OOE+OO 1.10E+00 5.76E-0 1 0.OOE+0O 0.OOEO00 O.OOE+00 0.OOE+00 1.87E-03 4.48E-04 2.77E-01 O.OOE+00 1 .69E-03 0.OOE+00 0.OOE+00 8.57E-01 Annual 1.99E+00 2.57E-04 2.61E-02 8.02E-04 6.98E-05 2.70E-03 3.50E-03 9.57E-01 1.09E-03 5.13E-02 3.78E-02 5.87E-04 3.07E+00 C. Particulates No Nuclides Found D. Tritium H-3 Ci Ci Ci Ci 0.OOE+00 O.OOE+00 1 .60E-01 0.OOE+O0 0.QOE+00 0.OOE+/-00 1.44E-01 0.OOE+00 0.OOE+00 0.OOE+00 6.35E-01 0.OOE+00 0.OOE÷00 0.OOE+00 5.91E-02 0.OOE+O0 0.OOE-'00 0.OOE+00 9.99E-01 0.OOE+00 E. Gross Alpha No Nuclides Found If Not Detected, Nuclide is Not Reported.
Zeroes in this table indicates that no radioactivity was present at detectable levels.User: AI Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Florida Power & Light, St. Lucie Power Plant 2/17/2014 13:57 Reg. Guide 1.21, Table 1B, Gaseous Effluents
-Ground Level Release -Batch Mode Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Page 3 of 3 Batch Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Nuclides Released F. Carbon-14 No Nuclides Found Ci O.OOE+00 0.O0E+00 Q.OOE+00 0.OOE+00 0.OOE+00 If Not Detected, Nuclide is Not Reported.
Zeroes in this table indicates that no radioactivity was present at detectable levels.User: Al Locke [Server]:
PSLSA37 [Database]:
NEPSOEMP
.. .EMS Page 1 of 1 Tuesday, February 18, 2014 6:22:35AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table IA, Gaseous Effluents
-Summation of All Releases Unit: PSL1 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Uncertainty A. Fission and Activation Gases 1. Total Release 2. Average Release Rate for Period 3. Percent of Limit B. lodines and Halogens 1. Total Release 2. Average Release Rate for Period 3. Percent of Limit C. Particulates
- 1. Total Release 2. Average Release Rate for Period 3. Percent of Limit D. Tritium 1. Total Release 2. Average Release Rate for Period 3. Percent of Limit E. Gross Alpha 1. Total Release F. Carbon-14 1. Total Release 2. Average Release Rate for Period 3. Percent of Limit Ci uCi/s Ci uCi/s uCi/s Ci uCi/s Ci Ci uCi/s 1.93E+00O 2.48E-01 0.OOE+00 0.OOE+00 0.OOE+OO 0.OOEO00 1.66E+01 2.14E+i00 2.64E-08 2.21E+.00 2.84E-01 4.29E-01 5.461-02 0.OOE+00 0.OOE+00 0.00E4-O0 O.OOE+00 9.52E+00 1.21E+00 4.84E-09 2.84E+00 3.62E-01 9.19E-01 1.16E-01 0.OOE+00 0.OOE-.00 0.OOEO00 0.OOE+O0 4.31E-01 5.43E-02 3.I5E-08 2.87E+00 3.61E-01 5.60E-01 7 .05E-02 1.02E-06 1.28E-07 0.OOE+00 0.OOE+/-00 2.94E+00.3.70E-01 5.34E-09 1.23E+00 1.55E-01 3.84E+00 1.22E-01 1.02E-06 3.23E-08 0.OOE+00 O.OOE+00 2.95E+I01 9.36E-01 6.81E-08 9.16E+00 2.90E-01*User: AI Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Page 1 of 3 E M S Tuesday, February 18, 2014 8:33:52AMMa,,.t.,e A .:rc. Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 1B, Gaseous Effluents
-Ground Level Release -Continuous Mode Unit: PSL1 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Continuous Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases Xe-133 Ci 1.60E+00 O.OOE+0O O.OOE+00 O.OOE+O0 1.60E+00 B. lodines and Halogens 1-131 Ci 0.OOE+00 0.OOE+00 O.OOE+00 1.02E-06 1.02E-06 C. Particulates No Nuclides Found Ci 0.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 D. Tritium H-3 Ci 1.65E+01 9.41E+00 a.ODE+00 2.91E+00 2.88E+01 E. Gross Alpha G-Alpha Ci 2.64E-08 4.84E-09 3.15E-08 5.34E-09 6.81E-08 F. Carbon-14 C-14 Ci 2.21E+00 2.84E+00 2.87E+00 1.23E+00 9.16E+00 If Not Detected, Nuclide is Not Reported.
Zeroes in this table indicates that no radioactivity was present at detectable levels.User: Al Locke [Server]:
PSLSA37 [Database]:
NEPSOEMP Florida Power & Light, St. Lucie Power Plant 2/18/2014 8:33 Page 2 of 3 Reg. Guide 1.21, Table 1B, Gaseous Effluents
-Ground Level Release -Batch Mode Unit: PSL1 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released A. Fission and Activation Gases Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Ar-41 Kr-85m Kr-85 Kr-87 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 Total For Period Ci Ci Ci Ci Ci Ci Ci Ci Ci a Ci Ci 2.66E-01 3.33E-05 2.61E-02 1.28E-04 6.52E-04 2.69E-03 3.13E-02 4.68E-04 2.99E-03 0.OOE+00 0.00E+00 3.30E-01 3.56E-01 1.62E-04 0.OOE+00 4.98E-04 1.81E-04 3.66E-04 4.28E-02 1.65E-04 1.66E-02 1.24E-02 5.87E-04 4.29E-01 3.62E-01 0.OOE--00 0.OOE+00 0.OOE+0O 0.OOE+/-OO 0.OQE-i-O 5,28E-01 O.OOE+/-00 2.86E-02 0.00E4-0O 0.OOE-I00 9.19E-01 4.47E-01 O.OOE+00 a.OOE+/-00 0.OOE+00 1.87E-03 4.48E-04 1.11lE-01 0.OOE+O0 6.12E-05 O.OOE+0O 0.OOE+00.5.60E-01 Annual 1.43E+00 1.95E-04 2.61E-02 6.27E-04 2.70E-03 3.50E-03 7.13E-01 6.32E-04 4M83E-02 1.24E-02 5.87E-04 2.24E+00 B. Iodines and Halogens No Nuclides Found C. Particulates No Nuclides Found D. Tritium H-3 E. Gross Alpha No Nucl ides Found Ci Ci Ci Ci 0.OOE+0O 0.OOE+O0 1.38E-01 0.OOE+00 O.OOE+00 0.OOE+0O 1.08E-01 0.00E+00 0.OOE+00 0.OOE+O0 4.31E-01 0.OOE+00 0.OOE+00 O.OOE+0O 3.44E-02 0.OOE+OO O.OOE+O0 0.COE÷00 7. 12E-01 0.OaE+aO If Not Detected, Nuclide is Not Reported.
Zeroes in this table indicates that no radioactivity was present at detectable levels.User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Florida Power & Light, St. Lucie Power Plant 2/18/2014 8:33 Reg. Guide 1.21, Table 1B, Gaseous Effluents
-Ground Level Release -Batch Mode Unit: PSL1 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Page 3 of 3 Batch Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Nuclides Released F. Carbon-14 No Nuclides Found Ci 0.O0E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 If Not Detected, Nuclide is Not Reported.
Zeroes in this table indicates that no radioactivity was present at detectable levels.User: Al Locke [Server]:
PSLSA37 [Database]:
NEPSOEMP Page 1 of 1_E M S .Tuesday, February 18, 2014 6:25:29AM..t JtI L'..J Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 1A, Gaseous Effluents
-Summation of All Releases Unit: PSL2 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Uncertainty A. Fission and Activation Gases 1. Total Release Ci 1.69E-01 2.74E+00 1.83E-01 2.96E-01 3.39E+00 2. Average Release Rate for Period uCi/s 2.18E-02 3.49E-01 2.31E-02 3.73E-02 1.08E-01 3. Percent of Limit %B. lodines and Halogens 1. Total Release Ci 0.OOE+00 1.65E-08 O.OOE+00 1.63E-05 1.63E-05.2. Average Release Rate for Period uCi/s O.OOE+00 2.09E-09 O.OOE+00 2.05E-06 5.16E-07 3. Percent of Limit %C. Particulates
- 1. Total. Release Ci O.OOE+00 0.OOE+00 0.OOE+00 1.43E-06 1.43E-06 2. Average Release Rate for Period uCi/s 0.OOE+00 0.OOE+00 O.OOE+00 1.80E-07 4.53E-08 3. Percent of Limit %D. Tritium 1. Total Release Ci 6.90E-01 5.93E-01 2.04E-01 5.77E+00 7.26E+00 2. Average Release Rate for Period uCi/s 8.88E-02 7.55E-02 2.56E-02 7.26E-01 2.30E-01 3. Percent of Limit %E. Gross Alpha 1. Total Release Ci 8.76E-08 4.45E-10 1.06E-07 2.43E-08 2.18E-07 F. Carbon-14 1. Total Release Ci 2.84E+00 2.71E+00 2.92E+00 2.84E+00 1.13E+01 2. Average Release Rate for Period uCi/s 3.65E-01 3.44E-01 3.67E-01 3.57E-01 3.58E-01 3. Percent of Limit %User: A] Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP EIli, u J.1 "(imv,jwre Page 1 of 2 Tuesday, February 18, 2014 8:35:09AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 1B, Gaseous Effluents
-Ground Level Release -Continuous Mode Unit: PSL2 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Continuous Mode Nuclides Released A. Fission and Activation Gases Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Xe-131m Xe-135 Total For Period B. lodines and Halogens Ci Ci Ci Ci Ci Ci 0.OOE-I00 0.OOE+00 O.OOE+OO 0.OOE+0O 0.GOE+00 O.OOE+0O 2.48E+00 7.58E-02 2-.-56E+0O 1.65E-08 0.OOE+O0 1.5-08 0.OOE+00 0.OOE+00 D.OOE+OO O.OOE+00 O.OOE+00 O.OOE+0O 0.OOE+/-00 0.OOE+00 O.ODE+OO 4.93E-06 1. 13E-05 1.63E-05 Annual 2.48E+00 7.58E-02 2.56E+00 4.94E-06 1.13E-05 1.63E-05 1-131 1-133 Total For Period C. Particulates Co-60 D. Tritium H-3 E. Gross Alpha G-Alpha F. Carbon-14 C-14 0 a Ci 0.OOE+00 6.68E-01 8.76E-08 2.84E+a00 O.OOE+00 5.57E-01 4.45E-10 2.71E+00 0.OaE+00 0.OOE+00 1.06E-07 2.92E+00 1.43E-06 5.74E+00 2.43E-08 2.84E+00 1.43E-06 6.97E+00 2.18E-07 1.13E+01 If Not Detected, Nuclide is Not Reported.
Zeroes in this table indicates that no radioactivity was present at detectable levels.User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Florida Power & Light, St. Lucie Power Plant 2/18/2014 8:35 Page 2 of 2 Reg. Guide 1.21, Table 1B, Gaseous Effluents
-Ground Level Release -Batch Mode Unit: Starting:
1-Jan-2013 PSL2 Ending: 31-Dec-2013.Batch Mode Nuclides Released A. Fission and Activation Gases Units 1ST Quarter 2ND Quarter 3RD Quarter Ar-41 Kr-85m Kr-87 Kr-88 Xe-133 Xe-135m Xe-135 Xe-137 Total For Period Ci Ci Ci Ci Ci Ci Ci Ci Cl 1.41E-01 5.80E-06 8.45E-06 0.OOE+O0 1.85E-02 4.60E-04 4.O8E-04 9.42E-03 1.69E-01 1.41lE-01 5.65E-05 1.31E-04 6.98E-05 2.71E-02 0.OOE+OQ 7.93E-04 1.59E-02 1.5-01 1.50E-01 0.OOE-400 3,57E-05 cJ.OOE+0O 3.27E-02 0.0011+00 2.54E-04 0.OOE+00 1.83E-01 4TH Quarter 1.29E-01 O.OOE+00 0.OOE+00 O.OOE+00 1.66E-01 0.0OE+00 1.63E-03 O.OOE+00 2.96E-01 Annual 5.61E-01 6.23E-05 1.75E-04 6.98E-05 2.44E-01 4.60E-04 3.09E-03 2.54E-02 8.34E-01 B. Iodines and Halogens No Nuclides Found C. Particulates No Nuclides Found D. Tritium H-3 E. Gross Alpha No Nuclides Found Ci Ci Ci Ci Ci 0.OOE+0O 0.OOE+00 2.19E-02 0.OOE+0O 0.OOE+00 Q.OOE+00 0.OOE+00 3.61E-02 0.OOE+00 0.OOE+00 O.OCE+00 O.OOE÷00 2.04E-01 0.OOE+O0 0. OQE+00 0.OOE+O0 0.OOE+00 2.48E-02 0.OOE+/-00 O.OOE+00 0.OOE+00 0.OOE+00 2.87E-01 0.OOE+00 0.OOE+00 F. Carbon-14 No Nuclides Found If Not Detected, Nuclide is Not Reported.
Zeroes in this table indicates that no radioactivity was present at detectable levels.User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Page 1 of 1....E M S :L VMonday, February 17, 2014 2:11:31PM Efftlne.w Mam ..n,-,icu _Soft.'.rv Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 2A, Liquid Effluents
-Summation of All Releases Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Uncertainty A. Fission and Activation Products 1. Total Release 2. Average Concentration
- 3. Percent of Limit B. Tritium 1. Total Release 2. Average Concentration
- 3. Percent of Limit C. Dissolved and Entrained Gases 1. Total Release 2. Average Concentration
-- 3. Percent of Limit D. Gross Alpha Activity 1. Total Release 2. Average Concentration E. Primary Liquid Release Volume 1. Total Release F. Dilution Volume 1. Total Release Ci uCi/mL%uCi/mL%C1 uCi/mL Ci uCi/mL Liters Liters mA3/s 5.51E-03 3.40E-10 5.01E+01 3.09E-06 1.15E-04 7.08E-12 a.OOE+00 0.OOE+00 6.34E+05 1.62E+10 0.QOE+00 2.11E-03 7.84E-11 6.91E+01 2.57E-06 1.54E-04 5.72E-12 0.OOE+00 0.OOE+/-00 1.85E+07 2.6817+10 0.OOE+00 7.45E-03 1.86E-10 1.53E+02 3.81E-06 5.11E-04 1.28E-11 O.OOE+00 O.OOE+/-00 1.49E+06 4.0 1E+I10 0.OOE+00 2.62E-02 2.80E-10 2.72E+02 2.90E-06 1.28E-02 1.36E-10 0.OOE+00 0.00E+00 3.08E+06 9.39E+10 O.OOE+00 4.13E-02 2-33E-10 5.44E+02 3.07E-06 1.36E-02 7.66E-11 0.OOE-I00 0.OOE-I00 2.37E+07 1.77E+11 O.OOE+00 G. Average Stream Flow 1. Total Release User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP
" EMS Page 1 of 1 Tuesday, February 18, 2014 8:51:28AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 2A, Liquid Effluents
-Summation of All Releases Unit: PSL1 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Total Release A. Fission and Activation Products 1. Total Release 2. Average Concentration
- 3. Percent of Limit B. Tritium 1. Total Release 2. Average Concentration
- 3. Percent of Limit C. Dissolved and Entrained Gases 1. Total Release 2. Average Concentration
- 3. Percent of Limit D. Gross Alpha Activity 1. Total Release 2. Average Concentration E. Primary Liquid Release Volume 1. Total Release F. Dilution Volume 1. Total Release G. Average Stream Flow 1. Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Uncertainty a uCi/mL Ci uCi/mL Ci uCQ/mL Ci uCi/mL Liters Liters mAr3/s 2.76E-03 3.40E-10 2.51E+01 3.09E-06 5.74E-05 7.08E-12 0.OOE-i00 0.OOE-e00 3.17E+05 8.10E4-09 0.00E+00 1 .05E-03 7.84E-11 3.45E+01 2.57E-06 7.6817-05 5.72E-12 0.OOE+/-0O 0.OOE+00 9.27E+06 1.34E+10 0.OOE+00 3.73E-03 1.86E-10 7.64E+01 3.81E-06 2.56E-04 1.28E-11 0.OOE+0O 0.OOE+00 7.43E+05 2.OOE+1O 0.OOE÷00 1.31E-02 2.80E-10 1.36E+02 2.90E-06 6.3917-03 1-36E- 10 O.OOE+00 0.OOE+00 1 .54E+06 4.70E+410 0.OOE+00 2.07E-02 2.33E-10 2.72E+02 3.07 E-06 6.78E-03 7.66E-11 0.00E+00 0.OOE-'00 1.19E+07 8.85E+10 O.OOE+00 User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP EMS Effluiwn:
Ntain,.unt SoftU;iarv Page 1 of 1 Tuesday, February 18, 2014 6:27:01AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 2A, Liquid Effluents
-Summation of All Releases Unit: PSL2 Starting:
l-Jan-2013 Ending: 31-Dec-2013 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Uncertainty A. Fission and Activation Products 1. Total Release 2. Average Concentration
- 3. Percent of Limit B. Tritium 1. Total Release 2. Average Concentration
- 3. Percent of Limit C. Dissolved and Entrained Gases 1. Total Release 2. Average Concentration
- 3. Percent of Limit D. Gross Alpha Activity 1. Total Release 2. Average Concentration E. Primary Liquid Release Volume 1. Total Release F. Dilution Volume 1. Total Release G. Average Stream Flow 1. Total Release Ci uCi/mL Ci uCi/mL Ci uCi/mL Ci uCi/mL Liters Liters mA3/s 2.76E-03 3.40E-10 2.51E+01 3.09E-06 5.74E-05 7.08E-12 O.OOE+00 0.OOE+00 3. 17E+05 8.10E+09 0.OOE+00 1.05E-03 7.84E-1 1 3.45E+01 2.57E-06 7.68E-05 5.72E-12 0.OOE+00 0.OOE+00 9.27E+06 1.34E+10 O.OOE+00 3.73E-03 1.86E-10 7.64E+01 3.8 1E-06 2.56E-04 1.28E-11 0.OOE÷00 0.OOE+00 7.43E+05 2.OOE+10 0.OOE+O0 1.31E-02 2.80E-10 1.36E-N02 2.90E-06 6.39E-03 1.36E-10 0.OOE+00 0.OOE+00 1.54E+06 4.70E+ 10 0.OOE+00 2.07E-02 2.33E-10 2.72E+02 3.07E-06 6.78E-03 7.66E-11 0.OOE+00 O.OOE+O0 1.19E+07 8.85E+10 O.OOE+00 User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Florida Power & Light, St. Lucie Power Plant 2/18/2014 8:51 Page 2 of 3 Reg. Guide 1.21, Table 2B, Liquid Effluents
-Batch Mode Unit: PSL1 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Products C-14 Ci 8.12E-04 O.OOE+00 1.41E-03 1.01E-02 1.23E-02 Cr-51 Ci 0.OOE+00 6.48E-05 0.OOE+00 1.41E-04 2.05E-04 Mn-54 Ci 2.32E-05 2.92E-05 3.09E-05 3.78E-05 1.21E-04 Fe-55 Ci 1.35E-03 O.OOE+00 0.O0E+00 0.O0E+00 1.35E-03 Fe-59 Ci 1.41E-05 6.87E-06 1.89E-06 6.81E-06 2.97E-05 Co-57 Ci O.OOE+00 1.36E-06 1.04E-06 0.OOE+00 2.41E-06 Co-58 -Ci 1.49E-04 2.71E-04 2.08E-04 7.39E-04 1.37E-03 Co-60 Ci 1.88E-04 2.45E-04 4.17E-04 4.54E-04 1.30E-03 Zn-65 Ci 8,87E-06 1.37E-06 6,36E-06 1.44E-05 3.10E-05 Sr-91 Ci 0.O0E+00 O.OOE+00 8.63E-06 3.08E-06 1.17E-05 Zr-95 Ci 2.04E-05 2.04E-05 1.23E-05 5.53E-05 1.08E-04 Zr-97 Ci O.OOE+00 0.OOE+00 0.0OE+00 3.76E-05 3.76E-05 Nb-95 Ci 3.91E-05 4.93E-05 1.76E-05 1.15E-04 2.21E-04 Nb-97 Ci 3.45E-05 6.76E-05 8.07E-04 4.54E-04 1.36E-03 Tc-99m Ci 0.OOE+00 1.26E-06 O.OOE+00 0.OOE+00 1.26E-06 Ru-103 Ci 0.OOE+00 0.OOE+00 0.OOE+00 6.23E-07 6.23E-07 Ag-110m Ci 3.62E-05 6.51E-05 6.05E-04 3.52E-04 1.06E-03 Sn-113 Ci O.OOE+00 0.OOE+00 O.OOE+00 2.78E-06 2.78E-06 Sb-124 Ci 0.OOE+00 6.19E-06 3.36E-06 6.98E-05 7.93E-05 Sb-125 Ci 5.43E-05 7.69E-05 1.54E-04 2.42E-04 5.27E-04 Te-129m Ci 0.OOE+00 1.32E-04 0.OOE+00 1.36E-04 2.69E-04 Te-132 Ci 0.OOE+00 0.OOE+00 0.OOE+00 8.58E-05 8.58E-05 1-130 Ci 0.OOE+00 2.14E-06 O.OOE+00 0.0OE+00 2.14E-06 1-131 Ci 2.45E-06 1.78E-06 4.37E-06 5.41E-06 1.40E-05 1-132 Ci O.OOE+00 O.OOE+00 0.OOE+00 7.59E-05 7.59E-05 1-133 Ci 2.57E-06 0.OOE+00 3.60E-06 3.28E-06 9.45E-06 If Not Detected, Nuclide is Not Reported.
Zeroes in this table indicates that no radioactivity was present at detectable levels.User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Florida Power & Light, St. Lucie Power Plant 2/18/2014 8:51 Page 3 of 3 Reg. Guide 1.21, Table 2B, Liquid Effluents
-Batch Mode Unit: PSL1 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released 1-134 1-135 Cs-136 Cs-137 Cs-138 Ba-140 La-140 W-187 Total For Period Units Ci Ci Ci Ci Ci Ci Ci Ci Ci 1ST Quarter 0.OOE+00 O.00E+00 O.OQE+00 7.52E-06 O.OOE+O0 1.23E-05 0.OOE+00 0.OOE+00 2.76E-03 2ND Quarter 0.OOE+00 0.OOE+00 4.91E-06 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 4.75E-06 1.05E-03 3RD Quarter 3.45E-06 3.42E-06 1.36E-06 O.OOE+00 1.43E-05 O.OOE+O0 8.72E-06 0.OOE+00 3.73E-03 4TH Quarter 0.OOE+00 3.99E-06 1.34E-06 5.25E-06 O.OOE+00 7.15E-06 4.70E-06 O,OOE+O0 1.31E-02 Annual 3.45E-06 7.41E-06 7.61E-06 1.28E-05 1.43E-05 1.95E-05 1.34E-05 4.75E-06 2.07E-02 B. Titium H-3 Ci 2.51E+01 3.45E+01 7.64E+01 1.36E+02.2.72E+02 C. Dissolved and Entrained Gases Ar-41 Kr-87 Xe-131m Xe-133m Xe-133 Xe-135 Total For Period Ci Ci Ci Ci Ci Ci Ci O.OOE+00 0.oaE+o0 0.OaE+o0 O.OOE+00 4.59E-05 1. 14E-05 5.74E-05 0.OOE+O0 o.oaE+00 0.OOE+00 0.OOE+O0 6.55E-05 1.13E-05_7.68E-05 1.89E-06 0.OOE+Q0 0.OOE+00 0.OOE+O0 1.94E-04 5.95E-05 2.56E-04 0.OOE+00 8.66E-07 6.52E-05 1.94E-05 6.29E-03 1.49E-05 6.39E-03 1.89E-06 8.66E-07 6.52E-05 1 .94E-05 6.60E-03 9.71E-05 6.78E-03 D. Gross Alpha Activity No Nuclides Found Ci O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+O0 O.OOE+00 If Not Detected, Nuclide is Not Reported.
Zeroes in this table indicates that no radioactivity was present at detectable levels.User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Page 1 of 1-ES .Tuesday, February 18, 2014 8:52:18AM.-; ',. , W, S0f4V.;,r, Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 2A, Liquid Effluents
-Summation of All Releases Unit: PSL2 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Uncertainty A. Fission and Activation Products 1. Total Release Ci 2.76E-03 1.05E-03 3.73E-03 1.31E-02 2.07E-02 2. Average Concentration uCi/mL 3.40E-10 7.84E-11 1.86E-10 2.80E-10 2.33E-10 3. Percent of Limit %B. Tritium 1. Total Release Ci 2.51E+01 3.45E+01 7.64E+01 1.36E+02 2.72E+02 2. Average Concentration uCi/mL 3.09E-06 2.57E-06 3.81E-06 2.90E-06 3.07E-06 3. Percent of Limit %C. Dissolved and Entrained Gases 1. Total Release Ci 5.74E-05 7.68E-05 2.56E-04 6.39E-03 6.78E-03 2. Average Concentration uCi/mL 7.08E-12 5.72E-12 1.28E-11 1.36E-10 7.66E-11 3. Percent of Limit %D. Gross Alpha Activity 1. Total Release Ci 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 2. Average Concentration uCi/mL 0.OOE+00 O.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 E. Primary Liquid Release Volume 1. Total Release Liters 3.17E+05 9.27E+06 7.43E+05 1.54E+06 1.19E+07 F. Dilution Volume 1. Total Release Liters 8.10E+09 1.34E+10 2.OOE+10 4.70E+10 8.85E+10 G. Average Stream Flow 1. Total Release mA3/s 0.OOE+00 0.OOE+00 0.ODE+00 O.OOE+00 0.OOE+00 User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Florida Power & Light, St. Lucie Power Plant 2/18/2014 8:52 Page 2 of 3 Reg. Guide 1.21, Table 2B, Liquid Effluents
-Batch Mode Unit: PSL2 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released A. Fission and Activation Products Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual C-14 Cr-51 Mn-54 Fe-55 Fe-59 Co-57 Co-58 Co-60 Zn-65 Sr-91 Zr-95 Zr-97 Nb-95 Nb-97 Tc-99m Ru-103 Ag-110m Sn-113 Sb-124 Sb-125 Te-129m Te-132 1-130 1-131 1-132 1-133 Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 8.12E-04 O.OOE+Q0 2.32E-05 1.35E-03 1.41E-05 0.OOE+00 1 .49E-04 1.88E-04 8.87E-06 0.OOE+00 2.04E705 O.OOE+00 3.91E-05 3.45E-05 Q.OOE+00 0.OOE+00 3.62E-05 O.OOE+OO O.OOE+O0 5.43E-05 0.OOE+00 O.OOE+00 O.OOE+0O 2.45E-06 0.O0E+00 2.57E-06 0.OOE+Q0 6.48E-05 2.92E-05 O.O0E+00 6.87E-06 1.36E-06 2.71E-G4 2.45E-04 1.37E-06 O.OOE+00 2.04E-05 0.OOE+0O 4.93E-05 6.76E-05 1 .26E-06 O.OOE+00 6.51E-05 O.OOE-i0Q 6.19E-06 7.69E-05 1.32E-04 O.00E+00 2. 14E-06 1.78E-06 0.OOE+OO 0.OOE+OO 1.41E-03 0.OOE+00 3.09E-05 O.OOE+00 1.89E-06 1.04E-06 2.08E-04 4.17E-04 6.36E-06 8.63E-06 1.23E-05 0.00E+00 1.76E-05 8.07E-04 O.OOE+00 0.OOE+00 6.05E-04 0.OOE+00 3.36E-06 1.54E-04 0.0OE+00 0.OOE+O0 0.OOE+OO 4.37E-06 O.OOE+00 3.60E-06 1.01E-02 1.4 1E-04 3.78E-05 0.OOE+0O 6.81E-06 0.00E+00 7.39E-04 4. 54E-04 1.44E-05 3.08E-06 5.53E-05 3.76E-05 1. 15E-04 4.54E-04 0.OOE+00 6.23E-07 3.52E-04 2.78E-06 6.98E-05 2.42E-04 1.36E-04 8.58E-05 0.OOE+00 5.41E-06 7.59E-05 3.28E-06 1.23E-02 2,05E-04 1.21E-04 1.35E-03 2.97E-05 2.41E-06 1.37E-03 1.30E-03 3.1OE-05 1.17E-05 1.08E-04 3.76E-05 2.21E-04 1.36E-03 1.26E-06 6.23E-07 1.06E-03 2.78E-06 7.93E-05 5.27E-04 2.69E-04 8.58E-05 2.14E-06 1.40E-05 7.59E-05 9.45E-06 If Not Detected, Nuclide is Not Reported.
Zeroes in this table indicates that no radioactivity was present at detectable levels.User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Florida Power & Light, St. Lucie Power Plant 2/18/2014 8:52 Page 3 of 3 Reg. Guide 1.21, Table 2B, Liquid Effluents
-Batch Mode Unit: PSL2 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released 1-134 1-135 Cs-136 Cs-137 Cs-138 Ba-140 La-140 W-187 Total For Period Units Ci Ci Ci Ci Ci Ci Ci Ci ci 1ST Quarter O.OOE+0O O.OOE+00 O.OOE+00 7.52E-06 O.OOE+00 1.23E-05 O.OOE+00 O.OOE+00 2.76E-03 2ND Quarter O.OOE+00 O.OOE+0O 4.91E-06 O,OOE+O0 O.OOE+0O O.OOE+00 O.OOE+00 4.75E-06 1.05E-03 3RD Quarter 3.45E-06 3.42E-06 1.36E-06 O.OOE+00 1.43E-05 O.OOE+O0 8.72E-06 O.OOE+O0 3.73E-03 4TH Quarter Annual O.OOE+00 3.99E-06 1.34E-06 5.25E-06 O.OOE+O0 7.15E-06 4.70E-06 O.OOE+0O 1.31E-02 3.45E-06 7.41E-06 7.61E-06 1.28E-05 1.43E-05 1.95E-05 1.34E-05 4.75E-06 2.07E-02 B. Tritium H-3 C. Dissolved and Entrained Gases Ci 2.51E+01 3.45E+01 7.64E+01 1.36E+02 2.72E+02 Ar-41 Kr-87 Xe-131m Xe-133m Xe-133 Xe-135 Total For Period Ci Ci Ci Ci Ci Ci Ci 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+O0 4.59E-05 1. 14E-05 5.74E-05 O.OOE+O0 0.OOE+00 0.OOE+0O 0.OOE+00 6.55E-05 1.13E-05 7.68E-05 1 .89E-06 0.OOE-i00 0.OOE+00 0.OOE+00 1 .94E-04 5.95E-05 2.56E-04 0.OOE+00 8-66E-07 6.52E-05 1.94E-05 6.29E-03 1 .49E-05 6.39E-03 1.89E-06 8.66E-07 6.52E-05 1.94E-05 6.60E-03 9.71E-05 6.78E-03 D. Gross Alpha Activity No Nuclides Found Ci O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+00 If Not Detected, Nuclide is Not Reported.
Zeroes in this table indicates that no radioactivity was present at detectable levels.User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Eflun. Mal."i uzt Sx tvart.Page 1 of 3 Monday, February 17, 2014 2:12:13PM Florida Power & Light St. Lucie Power Plant Nuclides Released A. Fission and Activation Products No Nuclides Found B. Tritium No Nuclides Found C. Dissolved and Entrained Gases No Nuclides Found D. Gross Alpha Activity No Nuclides Found Reg. Guide 1.21, Table 2B, Liquid Effluents
-Continuous Mode Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Continuous Mode Units 1ST Quarter 2ND Quarter 3RD Quarter Ci O.OOE+O0 O.OOE+00 0.OOE+00 Ci O.OOE+O0 O.OOE+O0 O.OOE+00 Ci O.OOE+00 O.OOE+00 O.OOE+O0 Ci O.OOE+00 O.OOE+00 O.OOE+00 4TH Quarter O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+0O Annual O.OOE+00 O.OOE+O0 O.OOE+O0 O.OOE+0O If Not Detected, Nuclide is Not Reported.
Zeroes in this table indicates that no radioactivity was present at detectable levels.User: Al Locke [Server]:
PSLSA37 [Database]:
NEPSOEMP Florida Power & Light, St. Lucie Power Plant 2/17/2014 14:12 Page 2 of 3 Reg. Guide 1.21,, Table 2B, Liquid Effluents
-Batch Mode Unit: Site Starting:
l-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released A. Fission and Activation Products Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter C-14 Cr-51 Mn-54 Fe-55 Fe-59 Co-57 Co-58 Co-60 Zn-65 Sr-91 Zr-95 Zr-97 Nb-95 Nb-97 Tc-99m Ru-103 Ag-110m Sn-113 Sb-124 Sb-125 Te-129m Te-132 1-130 1-131 1-132 1-133 1.62E-03 Q.OOE+O0 4.65E-05 2.70E-03 2.82E-05 0.OOE+0O 2.97E-04 3.77E-04 1.77E-05 0.OOE-400 4.08E-05 Q.OOE+00 7.82E-05 6.90E-05 0.OOE+00 0.OOE+00 7.25E-05 0.OOE+O0 0.OOE+0O 1 .09E-04 0.OOE+00 0.OOE+/-00 0.OOE+00 4.90E-06 0.OOE+00 5. 15E-06 0.OOE+/-OO 1.30E-04 5.84E-05 0.OOE+00 1.37E-05 2.73E-06 5.42E-04 4.90E-04 2.75E-06 0.OOE+Q0 4.09E-05 0.OOE+00 9.85E-05 1.35E-04 2.53E-06 0.OOE+O0 1.30E-04 0.OOE+00 1.24E-05 1 .54E-04 2.65E-04 0.OOE+00 4.29E-06 3.56E-06 0.OOE+00 0.OOE+00 2.83E-03 0.OOE+O0 6.19E-05 0.OOE+00 3.77E-06 2.09E-06 4.17E-04 8.35E-04 1.27E-05 1.73E-05 2.45E-05 0.O0E+00 3.53E-05 1.61E-03 0.OOE+00 0.OOE+00 1.21E-03 0.OOE+00 6.71E-06 3.08E-04 0,OOE+00 0.OOE+00 0.OOE+00 8.74E-06 0.OOE+00 7.21E-06 2.01E-02 2.81E-04 7.57E-05 0.OOE+00 1.36E-05 0.00E+00 1.48E-03 9.08E-04 2.88E-05 6.17E-06 1.11E-04 7.53E-05 2.30E-04 9.07E-04 0.OOE+00 1.25E-06 7.04E-04 5.55E-06 1.40E-04 4.83E-04 2.73E-04 1.72E-04 0.OOE+00 1.08E-05 1.52E-04 6.56E-06 Annual 2.46E-02 4.11E-04 2.42E-04 2.70E-03 5.94E-05 4.82E-06 2.73E-03 2.61E-03 6.20E-05 2.34E-05 2.17E-04 7.53E-05 4.42E-04 2.73E-03 2.53E-06 1.25E-06 2.12E-03 5.55E-06 1.59E-04 1.05E-03 5.38E-04 1.72E-04 4.29E-06 2.80E-05 1.52E-04 1.89E-05 If Not Detected, Nuclide is Not Reported.
Zeroes in this table indicates that no radioactivity was present at detectable levels.User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Florida Power & Light, St. Lucie Power Plant 2/17/2014 14:12 Page 3 of 3 Reg. Guide 1.21, Table 2B, Liquid Effluents
-Batch Mode Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released 1-134 1-135 Cs-136 Cs-137 Cs-138 Ba-140 La-140 W-187 Total For Period Units Ci Ci Ci Ci Ci Ci Ci Ci Ci 1ST Quarter 0.OOE+Q0 O.OOE+0O O.OOE+0O 1.50E-05 0.OOE+O0 2.47E-05 0.QOE+O0 0.OOE-.0O 5.51E-03 2ND Quarter 0.OOE+00 0.OOE+00 9.82E-06 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 9.51E-06 2.11E-03 3RD Quarter 6.90E-06 6.84E-06 2.73E-06 O.OOE+O0 2.87E-05 0.OOE+00 1.74E-05 0.OOE+00 7.45E-03 4TH Quarter 0.OOE+00 7.97E-06 2.68E-06 1.05E-05 0.OOE+00 1.43E-05 9.40E-06 O.OOE+00 2.62E-02 B. Tritium Annual 6.90E-06 1.48E-05 1.52E-05 2.55E-05 2.87E-05 3.90E-05 2.68E-05 9.51E-06 4.13E-02 5.44E+02 3.79E-06 1.73E-06 1.30E-04 3.87E-05 1.32E-02 1.94E-04 1.36E-02 H-3 Ci 5,01E+01 6.91E+01 1.53E+02 2.72E+02 C. Dissolved and Entrained Gases Ar-41 Kr-87 Xe-131m Xe-133m Xe-133 Xe-135 Total For Period D. Gross Alpha Activity No Nuclides Found Ci Ci Ci Ci Ci Ci Ci 0.OOE+O0 0.OOE+00 0.OOE+00 0.OOE+00 9.19E-05 2.29E-05 1.15E-04 O.OOE+0O 0.OOE+O0 0.OOE+0O O.OOE+00 1.31E-04 2.26E-05 1.54E-04 3.79E-06 0.OOE+00 0.OOE+00 O.OOE+00 3.89E-04 1.19E-04 5.11E-04 O.OOE-NJO 1.73E-06 1.30E-04 3.87E-05 1 .26E-02 2.97E-05 1.28E-02 Ci O.OOE+00 O.OOE+O0 O.OOE+00 0.OOE+00 0.OOE+00 If Not Detected, Nuclide is Not Reported.
Zeroes in this table indicates that no radioactivity was present at detectable levels.User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP NRC Regulatory Guide 1.21 Reports Page Report Date : 2/11/2014 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/01/2013 to 12/31/2013 Percent Cutoff: 1 Waste Stream : Resins, Filters, and Evap Bottoms Waste Volume Curies % Error Class FtA3 MA3 Shipped (Ci)A 2.92E+02 8.27E+00 1.14E+01 +1-25%B 0.OOE+00 0.OOE+00 0.OOE+00 +/- 25%C 0.OOE+00 0.OOE+00 0.OOE+00 +/- 25%All 2.92E+02 8.27E+00 1.14E+01 +/-25%Waste Stream : Dry Active Waste DAW 48' Equip DAW 20' Sealand Waste Volume Curies %Error Class FtA3 MA3 Shipped (CI)A 2.05E+04 5.81E+02 1.11E+00 +/-25%B 0.OOE+00 0.OOE+00 0.OOE+00 +/-25%C 0.OOE+00 0.0OE+00 0.OOE+00 +/-25%All 2.05E+04 5.81E+02 1.11E+00 +/-25%Waste Stream Irradiated Components Waste Volume Curies % Error Class FtA3 MA3 Shipped (Ci)A 0.OOE+00 O.OOE+00 Q.OOE+00 +/-25%B 0.OOE+00 0.OOE+00 O.OOE+00 +/-25%C 0.OOE+00 0.OOE+00 0.OOE+00 +/-25%All 0.00E+00 0.OOE+00 0.00E+00 +/-25%
NRC Regulatory Guide 1.21 Reports Page 2 Report Date: 2/11/2014.Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/01/2013 to 12/31/2013 Percent Cutoff: 1 Waste Stream : Other Waste Waste Volume Curies % Error Class FtA3 M^3 Shipped (Ci)A 0.00E+00 0.OOE+00 0.00E+00 +1-25%B 0.OOE+00 0.OOE+00 0.OOE+00 +/-25%C 0.OOE+00 0,OOE+00 .0.00E+00
+/-25%All 0.00E+00 0.OOE+00 0.OOE+00 +/-25%Waste Stream : Sum of ALl 4 Categories DAW 48' Equip DAW 20' Sealand Waste Volume Curies % Error Class FtA3 MA3 Shipped (Cl)A 2,08E+04 5.89E+02 1.25E+01 +/-25%B 0.00E+00 0.OOE+00 O.OOE+00 +1-25%C 0.OOE+00 0,00E+00 0.OOE+00 +/-25%All 2.08E+04 5.89E+02 1.25E+01 +/-25%-Combined Waste Type Shipment,'Major Volume Waste Type Shown NRC Regulatory Guide 1.21 Reports Page 1 Report Date: 2/11/2014 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01101/2013 to 12/31/2013 Number of Shipments Mode of Transportation Destination 11 Hittman Transport (TN) EnergySolutions Bear Creek 2 Hittman Transport (SC) EnergySolutions LLC.
NRC Regulatory Guide 1.21 Reports Page 1 Report Date ; 2/11/2014 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/01/2013 to 12/31/2013 Percent Cutoff: 1 Resins, Filters, and Evap Bottom Waste Class A Nuclide Name Percent Abundance Curies H-3 10.030% 1.14E+00 C-14 2.922% 3.32E-01 Mn-54 2.670% 3.04E-01 Fe-55 22.869% 2.60E+00 Co-58 14.913% 1.70E+00 Co-60 13.896% 1.58E+00 Ni-63 25.629% 2.91E+00 Zn-65 1.096% 1.25E-01 Ag-110m 1.605% 1.82E-01 Sb-125 2.891% 3.29E-01 Resins, Filters, and Evap Bottom Waste Class All Nuclide Name Percent Abundance Curies H-3 10.030% 1.14E+00 C-14 2.922% 3.32E-01 Mn-54 2.670% 3.04E-01 Fe-55 22.869% 2.60E+00 Co-58 14.913% 1.70E+00 Co-60 13.896% 1.58E+00 Ni-63 25.629% 2.91 E+00 Zn-65 1.096% 1.25E-01 Ag-110m 1.605% 1.82E-01 Sb-125 2.891% 3.29E-01 Dry Active Waste Waste Class A Nuclide Name Percent Abundance Curies H-3 53.082% 5.90E-01 Fe-55 17.451% 1.94E-01 Co-58 6.393% 7.1OE-02 Co-60 6.881% 7.64E-02 Ni-63 9.693% 1.08E-01 Cs-137 1.601% 1.78E-02 Dry Active Waste Waste Class All Nuclide Name Percent Abundance Curies H-3 53.082% 5.90E-01 Fe-55 17.451% 1.94E-01 Co-58 6.393% 7.1OE-02 Co-60 6.881% 7.64E-02 Ni-63 9.693% 1.08E-01 Cs-137 1.601% 1.78E-02 Sum of All 4 Categories Waste Class A
.NRC Regulatory Guide 1.21 Reports Page- 2.Report Date : 2/11/2014 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/01/2013 to 12/31/2013 Percent Cutoff: 1 Nuclide Name Percent Abundance Curies H-3 13.862% 1.73E+00 C-14 2.666% 3.33E-01 Mn-54 2.502% 3.12E-01 Fe-55 22.387% 2.79E+00 Co-58 14.154% 1.77E+00 Co-60 13.271% 1.66E+00 Ni-63 24.211% 3.02E+00 Zn-65 1.007% 1.26E-01.Ag-110m 1.503% 1.88E-01 Sb-125 2.675% 3.34E-01 Sum of All 4 Categories Waste Class All Nuclide Name Percent Abundance Curies H-3 13.862% 1.73E+00 C-14 2.666% 3.33E-01 Mn-54 2.502% 3.12E-01 Fe-55 22.387% 2.79E+00 Co-58 14.154% 1.77E+00 Co-60 13.271% 1.66E+00 Ni-63 24.211% 3.02E+00 Zn-65 1.007% 1.26E-01 Ag-110m 1.503% 1.88E-01 Sb-125 2.675% 3.34E-01 NRC Regulatory Guide 1.21 Reports Page I Report Date : 2/11/2014 Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From 01/01/2013 to 12/31/2013 Manifest Number Date Shipped Waste Volume Used Burial volume Used FPL/PSL 13-058 10/10/2013 Yes FPL/PSL 13-046 7/26/2013 Yes FPIJPSL 13-044 7/24/2013 Yes FPL/PSL 13-043 7/23/2013 Yes FPL/PSL 13-038 7/11/2013 Yes FPL/PSL 13-036 7/10/2013 Yes FPS/PSL 13-031 6/13/2013 Yes FPL/PSL 13-025 5/22/2013 Yes FPL/PSL 13-026 5/22/2013 Yes FPL/PSL-13-018 5/13/2013 Yes FPLIPSL 13-016 4/25/2013 Yes FPL/PSL 13-013 4/10/2013 Yes FPL/PSL 13-012 4/10/2013 Yes 1EM\S Page 1 of 1 Tuesday, February 18, 2014 9:03:03AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec E3 -Doses due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Organ Dose Bone Limit Percent of Limit Units mRem mRem 1ST Quarter 1.69E-01 2ND Quarter 1.86E-01 3RD Quarter 1.94E-01 4TH Quarter 1.36E-01 Annual 6.85E-01 Liver mRem 1.73E-01 1.88E-01 1.94E-01 1.38E-01 6.94E-01 Limit mRem Percent of Limit %Total Body mRem 1.73E-01 1.88E-01 1.94E-01 1.38E-01 6.94E-01 Limit mRem Percent of Limit %Thyroid mRem 1.73E-01 1.88E-01 1.94E-01 1.40E-01 6.96E-01 Limit mRem Percent of Limit %Kidney mRem 2.20E-02 2.32E-02 2.30E-02 1.71E-02 8.53E-02 Limit mRem Percent of Limit %Lung mRem 1.73E-01 1.88E-01 1.94E-01 1.38E-01 6.94E-01 Limit mRem Percent of Limit %GI-LIi mRem 1.73E-01 1.88E-01 1.94E-01 1.38E-01 6.94E-01 Limit mRem Percent of Limit %Ulser: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Gas Status Summary Report Tuesday, February 18, 2014 09:31 Page 15 of 16 Period: Ann, 2013 Site/Unit/Discharge Point: Site Site Boundary NNG Doserate Summary -Note: All Doses in mRem/yr Receptor Agegroup Bone Liver Total Body Thyroid Kidney Lung GI-Lli Skin NW Site Boundary -In Infant 6.849E-01 6.939E-01 6.939E-01 6.956E-01 8.533E-02 6.939E-01 6.939E-01 0.OOOE+00 WNW Site Boundary -I Infant 1.681E-06 1.681E-06 1.681E-06 1.681E-06 1.681E-06 1.681E-06 1.681E-06 0.OOOE+00 Maximum Doserate by Organ: 6.849E-01 6.939E-01 6.939E-01 6.956E-01 8.533E-02 6.939E-01 6.939E-01 O.OOOE+00 Maximum Organ Doserate (mRem/yr):
6.956E-01 Maximum Total Body Doserate (mRem/yr):
6.939E-01 Site Boundary NG Doserate Summary Gas Receptor Location Gamma (mRad/yr)
Beta (mRad/yr)
Total Body (mRem/yr)
Skin (mRem/yr)NW Site Boundary 2.353E-03 1.325E-03 2.216E-03 3.456E-03 WNW Site Boundary 8.799E-04 5.610E-04 8.254E-04 1.321E-03 Maximum NG Dose Rate: 2.353E-03 1.325E-03 2.216E-03 3.456E-03 User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP I 4 Off im .itC t%14 Page 1 of 1 Tuesday, February 18, 2014 6:21:59AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec E3 -Doses due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: PSL1 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Organ Dose Bone Limit Percent of Limit Units mRem mRem 1ST Quarter 7.40E-02 2ND Quarter 9.52E-02 3RD Quarter 9.62E-02 4TH Quarter 4.12E-02 Annual 3.07E-01 Liver mRem 7.83E-02 9.77E-02 9.62E-02 4.19E-02 3,14E-01 Limit mRem Percent of Limit %Total Body mRem 7.83E-02 9.77E-02 9.62E-02 4.19E-02 3.14E-01 Limit mRem Percent of Limit %Thyroid mRem 7.83E-02 9.77E-02 9.62E-02 4.22E-02 3.14E-01 Limit mRem Percent of Limit %Kidney mRem 1.07E-02 1.24E-02 1.14E-02 5.22E-03 3.97E-02 Limit mRem Percent of Limit %Lung mRem 7.83E-02 9.77E-02 9.62E-02 4.19E-02 3.14E-01 Limit mRem Percent of Limit %GI-Lli mRem 7.83E-02 9.77E-02 9.62E-02 4.19E-02 3.14E-01 Limit mRem Percent of Limit %User: AI Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Gas Status Summary Report Tuesday, February 18, 2014 09:26 Page 9 of 10 Gas Status Summary Report Tuesday, February 18, 2014 09:26 Page 9 of 10 Period: Ann, 2013 Site/Unit/Discharge Point: PSL1 Site Boundary NNG Doserate Summary -Note: All Doses in mRem/yr Receptor Agegroup Bone Uver Total Body NW Site Boundary -In Infant 3.066E-01 3.141E-01 3.141E-01 WNW Site Boundary -I Infant 6.509E-09 6.509E-09 6.509E-09 Maximum Doserate by Organ: 3.066E-01 3.141E-01 3.141E-01 Thyroid 3.144E-01 6.509E-09 3.144E-01 Kidney 3.972E-02 6.509E-09 3.972E-02 Lung 3.141E-01 6.509E-09 3.141E-01 GI-Ui 3.141E-01 6.509E-09 3.141E-01 Skin 0.OOOE+00 0.OOOE+00 O.OOQE+00 Maximum Organ Doserate (mRem/yr):
Maximum Total Body Doserate (mRem/yr):
Site Boundary NG Doserate Summary Gas Receptor Location NW Site Boundary WNW Site Boundary Maximum NG Dose Rate: 3.144E-01 3.141E-01 Gamma (mRad/yr)
Beta (mRad/yr)1.692E-03 8.878E-04 6.226E-04 3.263E-04 1.692E-03 8.878E-04 Total Body (mRem/yr)1.597E-03 5.876E-04 1.597E-03 Skin (mRem/yr)2.437E-03 8.967E-04 2.437E-03 User: A] Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP 1flii Magesli4 SofC ~twxar Page 1 of 1 Tuesday, February 18, 2014 6:25:00AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec E3 -Doses due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: PSL2 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Organ Dose Bone Limit Percent of Limit Units mRem mRem 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter 9.49E-02 9.06E-02 9.76E-02 9.51E-02 Annual 3.78E-01 Liver mRem 9.50E-02 9.07E-02 9.76E-02 9.65E-02 3.80E-01 Limit mRem Percent of Limit %Total Body mRem 9.50E-02 9.07E-02 9.76E-02 9.65E-02 3.80E-01 Limit mRem Percent of Limit %Thyroid mRem 9.50E-02 9.07E-02 9.76E-02 9.79E-02 3.81E-01 Limit mRem Percent of Limit %Kidney mRem 1.13E-02 1.08E-02 1.16E-02 1.19E-02 4.56E-02 Limit mRem Percent of Limit %Lung mRem 9.50E-02 9.07E-02 9.76E-02 9.65E-02 3.80E-01 Limit mRem Percent of Limit %GI-Lli mRem 9.50E-02 9.07E-02 9.76E-02 9.65E-02 3.80E-01 Limit mRem Percent of Limit %User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Gas Status Summary Report Tuesday, February 18, 2014 09:27 Page 9 of 10 Gas Status Summary Report Tuesday, February 18, 2014 09:27 Page 9 of 10 Period: Ann, 2013 Site/Unit/Discharge Point: PSL2 Site Boundary NNG Doserate Summary -Note: All Doses in mRem/yr Receptor Agegroup Bone Liver Total Body NW Site Boundary -In Infant 3.783E-01 3.798E-01 3.798E-01 WNW Site Boundary -I Infant 1.675E-06 1.675E-06 1.675E-06 Thyroid 3.812E-01 1.675E-06 Kidney 4.561E-02 1.675E-06 Lung 3.798E-01 1.675E-06 GI-Lli 3.798E-01 1.675E-06 Skin 0.OOOE+OO 0O.cJOE+O0 Maximum Doserate by Organ: 3.783E-01 3.798E-01 3.798E-01 3.812E-01 4.561E-02 3.798E-01 3.798E-01 0.000E+00 Maximum Organ Doserate (mRem/yr):
3.812E-01 Maximum Total Body Doserate (mRem/yr):
3.798E-01 Site Boundary NG Doserate Summary Gas Receptor Location Gamma (mRad/yr)
Beta (mRad/yr)
Total Body (mRem/yr)
Skin (mRem/yr)NW Site Boundary 6.609E-04 4.372E-04 6.197E-04 1.019E-03 WNW Site Boundary 2.572E-04 2.347E-04 2.378E-04 4.239E-04 Maximum NG Dose Rate: 6,609E-04 4.372E-04 6.197E-04 1.019E-03 User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP iEfvIS iii '~Page 1 of 1 Tuesday, February 18, 2014 9:06:05AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec E2 -Air Doses Due To Gaseous Releases Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 NG Dose Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter 6.50E-04 Annual 2.35E-03 Gamma Air Limit mRad mRad 5.24E-04 5.91E-04 5.88E-04 Percent of Limit %Beta Air mRad 3.88E-04 4.01E-04 2.75E-04 2.61E-04 1.32E-03 Limit mRad Percent of Limit %NG Total Body mRem 4.89E-04 5.54E-04 5.56E-04 6.17E-04 2.22E-03 Limit mRem Percent of Limit %NG Skin mRem 7.86E-04 9.25E-04 8.35E-04 9.11E-04 3.46E-03 Limit mRem Percent of Limit %User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP
] EMS Page 1 of 1 Tuesday, February 18, 2014 9:06:36AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec E2 -Air Doses Due To Gaseous Releases Unit: PSL1 Starting:
1-Jan-2013 Ending: 31-Dec-2013 NG Dose Gamma Air Limit Percent of Limit Units 1ST Quarter 2ND Quarter 3RD Quarter mRad 3.65E-04 4.03E-04 4.24E-04 mRad 4TH Quarter 5.0OE-04 Annual 1.69E-03 Beta Air mRad 3.16E-04 1.69E-04 2.14E-04 1.89E-04 8.88E-04 Limit mRad Percent of Limit %NG Total Body mRem 3.39E-04 3.83E-04 4.0OE-04 4.75E-04 1.60E-03 Limit mRem Percent of Limit %NG Skin mRem 5.5 1E-04 5.82E-04 6.06E-04 6.97E-04 2.44E-03 Limit mRem Percent of Limit %User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP EI'v'1S IflM ~~i.n tS hvji.Page 1 of 1 Tuesday, February 18, 2014 9:07:04AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec E2 -Air Doses Due To Gaseous Releases Unit: PSL2 Starting:
1-Jan-2013 Ending: 31-Dec-2013 NG Dose Gamma Air Limit Units 1ST Quarter 2ND Quarter 3RD Quarter mRad 1.59E-04 1.88E-04 1.64E-04 mRad 4TH Quarter 1.50E-04 Annual 6.61E-04 Percent of Limit %Beta Air mRad 7.18E-05 2.32E-04 6.14E-05 7.16E-05 4.37E-04 Limit mRad Percent of Limit %NG Total Body mRem 1.51E-04 1.71E-04 1.56E-04 1.42E-04 6.20E-04 Limit mRem Percent of Limit %NG Skin mRem 2.34E-04 3.44E-04 2.29E-04 2.13E-04 1.02E-03 Limit mRem Percent of Limit %User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP
-E MS .: it:'mo : .a Page 1 of 1 Tuesday, February 18, 2014 9:11:34AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec El -Doses to a member of the public due to Liquid Releases Unit: Site Starting:
1-3an-2013 Ending: 31-Dec-2013 Ogan Dose Bone Limit Percent of Limit Units mRem mRem 1ST Quarter 4.48E-03 2ND Quarter 3RD Quarter 4TH Quarter 2.98E-05 2.28E-04 2.48E-03 Annual 6.78E-03 Liver mRem 1.99E-02 3.52E-04 9.08E-04 4.28E-03 2.55E-02 Limit mRem Percent of Limit %Total Body mRem 5.52E-03 3.38E-04 8.78E-04 4.14E-03 1.08E-02 Limit mRem Percent of Limit %Thyroid mRem 2.93E-04 2.76E-04 7.68E-04 3.86E-03 5.09E-03 Limit mRem Percent of Limit %Kidney mRem 4.17E-04 3.71E-04 9.78E-04 4.01E-03 5.77E-03 Limit mRem Percent of Limit %Lung mRem 2.28E-02 3.31E-04 8.62E-04 3.95E-03 2.78E-02 Limit mRem Percent of Limit %GI-Lli mRem 1.06E-02 3.19E-03 1.16E-02 2.08E-02 4.61E-02 Limit mRem Percent of Limit %User: AJ Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Liquid Status Summary Report Tuesday, February 18, 2014 09:15 Page 6 of 6 Period: Ann, 2013 Site/Unit/Discharge Point: Site Liquid Dose Summary -Note: All Doses in mRem Receptor AaeorouD Bone Liver Total Body Thyroid Kidney Lung GI-Lli Skin UaLuid Receptor -Teenacier Teenaqer 6.781E-03 2.546E-02 1.077E-02 4.946E-03 5.772E-03 2.783E-02 4.612E-02 0.000E+00 ULquid Recptor -Child Child 4.776E-03 1.415E-02 7.831E-03 5.092E-03 2.510E-03 1.516E-02 2.211E-02 0.O00E+00 Maximum Dose by Organ: 6.781 E-03 2.546E-02 1.077E-02 5.092E-03 5.772E-03 2.783E-02 4.612E-02 0.000E+00 Maximum Organ Dose (mRem): Maximum Total Body Dose (mRem): 4.612E-02 1.077E-02 User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Eil\4S UMUL4.~ 1U3t'i hi Page I of 1 Tuesday, February 18, 2014 6:21:06AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec El -Doses to a member of the public due to Liquid Releases Unit: PSL1 Starting:
l-Jan-2013 Ending: 31-Dec-2013 Ogan Dose Bone Limit Percent of Limit Units mRem mRem 1ST Quarter 2.24E-03 2ND Quarter 3RD Quarter 4TH Quarter 1.49E-05 1.14E-04 1.24E-03 Annual 3.39E-03 Liver mRem 9.96E-03 1.76E-04 4.54E-04 2.14E-03 1.27E-02 Limit mRem Percent of Limit %Total Body mRem 2.76E-03 1.69E-04 4.39E-04 2.07E-03 5.38E-03 Limit mRem Percent of Limit %Thyroid mRem 1.47E-04 1.38E-04 3.84E-04 1.93E-03 2.55E-03 Limit mRem Percent of Limit %Kidney mRem 2.09E-04 1.85E-04 4.89E-04 2.OOE-03 2.89E-03 Limit mRem Percent of Limit %Lung mRem 1.14E-02 1.65E-04 4.31E-04 1.97E-03 1.39E-02 Limit mRem Percent of Limit %GI-LIi mRem 5.28E-03 1.59E-03 5.80E-03 1.04E-02 2.31E-02 Limit mRem Percent of Limit %User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Liquid Status Summary Report Tuesday, February 18, 2014 09:15 Page 6 of 6 Period: Ann, 2013 Site/Unit/Discharge Point: PSL1 Liquid Dose Summary -Note: All Doses in mRem Receptor Acearouo Bone Liver Total Body Thyroid Kidney Lung GI-Lli Skin Liquid Receptor -Teenaqer Teenaqer 3.391E-03 1.273E-02 5.384E-03 2.473E-03 2.886E-03 1.391E-02 2.306E-02 0.OOOE+00 Liquid Recmtor -Child Child 2.388E-03 7.076E-03 3.915E-03 2.546E-03 1.255E-03 7.578E-03 1.105E-02 O.OOOE+00 Maximum Dose by Organ: 3.391E-03 1.273E-02 5.384E-03 2.546E-03 2.886E-03 1.391E-02 2.306E-02 0.000E+00 Maximum Organ Dose (mRem): Maximum Total Body Dose (mRem): 2.306E-02 5.384E-03 User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP TEUliiii r.Aii ~ n~. ~ an.Page 1 of 1 Tuesday, February 18, 2014 6:24:25AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec El -Doses to a member of the public due to Liquid Releases Unit: PSL2 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Ogan Dose Bone Limit Percent of Limit Units mRem mRem 1ST Quarter 2.24E-03 2ND Quarter 1.49E-05 3RD Quarter 1.14E-04 4TH Quarter 1.24E-03 Annual 3.39E-03 Liver mRem 9.96E-03 1.76E-04 4.54E-04 2.14E-03 1.27E-02 Limit mRem Percent of Limit %Total Body mRem 2.76E-03 1.69E-04 4.39E-04 2.07E-03 5.38E-03 Limit mRem Percent of Limit %Thyroid mRem 1.47E-04 1.38E-04 3.84E-04 1.93E-03 2.55E-03 Limit mRem Percent of Limit %Kidney mRem 2.09E-04 1.85E-04 4,89E-04 2.OOE-03 2.89E-03 Limit mRem Percent of Limit %Lung mRem 1.14E-02 1.65E-04 4.31E-04 1.97E-03 1.39E-02 Limit mRem Percent of Limit %GI-Lli mRem 5.28E-03 1.59E-03 5.80E-03 1.04E-02 2.31E-02 Limit mRem Percent of Limit %User: Al Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP Liquid Status Summary Report Tuesday, February 18, 2014 09:21 Page 6 of 6 Period: Ann, 2013 Site/Unit/Discharge Point: PSL2 Liquid Dose Summary -Note: All Doses in mRem Recepto Agegrou Bone Liver Total Body Thyroid Kidney Luna GI-Lli Skin Liquid Receqtor -Teenaqer Teenaqer 3.391E-03 1.273E-02 5.384E-03 2A73E-03 2.886E-03 1.391E-02 2.306E-02 O.OOOE+00 Liquid Recptor -Child Child 2.388E-03 7.076E-03 3.915E-03 2.546E-03 1.255E-03 7.578E-03 1-IO5E-02 O.O00E+O0 Maximum Dose by Organ: 3.391E-03 1.273E-02 5.384E-03 2.546E-03 2.886E-03 1.391E-02 2.306E-02 O.000E+00 Maximum Organ Dose (mRem): Maximum Total Body Dose (mRem): 2.306E-02 5.384E-03 User: All Locke[Server]:
PSLSA37 [Database]:
NEPSOEMP FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS I AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2013 THROUGH DECEMBER 31, 2013 3.4 Visitor Dose Dose to a Member of the Public from Activities Inside the Site Boundary Assessment of radiation dose from radioactive effluents to MEMBERS OF THE PUBLIC due to their activities inside the SITE BOUNDARY assumes the VISITOR to be a lifeguard at the Walton Rocks Beach recreation area. The visitor is assumed to be onsite for 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> per day for 312 days per year at a distance of 1.6 kilometers in the South East Sector. The VISITOR received exposure from each of the two reactors on the site. Actual Met Data was used to calculate Visitor Dose for Calendar Year 2013.VISITOR DOSE RESULTS FOR CALENDAR YEAR 2013 were: Noble Gas Dose mrad Gamma Air Dose 1.36E-03 Beta Air Dose 7.68E-04 Gas, Particulate, Iodine, Carbon Dose mrem Bone 4.IIE-01 Liver 4.17E-01 Thyroid 4.17E-0I Kidney 5.12E-02 Lung 4.17E-01 GI-LLI 4.17E-01 Total Body 4.17E-01