L-2014-044, Turkey Point, Units 3 and 4 - Annual Radioactive Effluent Release Report, January 2013 Through December 2013
ML14070A085 | |
Person / Time | |
---|---|
Site: | Turkey Point |
Issue date: | 12/31/2013 |
From: | Conboy T, Rios N, Vasquez J A Florida Power & Light Co |
To: | Office of Nuclear Reactor Regulation |
References | |
L-2014-044 | |
Download: ML14070A085 (68) | |
Text
0Florida Power and Light Turkey Point Plant Units 3 and 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT January 2013 through December 2013 Submitted by: NUCLEAR CHEMISTRY DEPARTMENT FLORIDA POWER AND LIGHT COMPANY AMe hm N. Rios, hemistry Manager Tom Conboy, Plant Ge rManager TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table of Contents EX ECU TIV E SU M M A RY ........................................................................................................
3 1.0 R EG U LA TO R Y LIM ITS ...........................................................................................................
3 2.0 EFFLUENT CONCENTRATION
..................................................................................................
4 3.0 A V E R A G E EN E R G Y ......................................................................................................................
4 4.0 MEASUREMENTS AND APPROXIMATIONS OF TOTAL ACTIVITY .................................
4 5.0 B A T C H RE L E A SE S ........................................................................................................................
7 6.0 UNPLANNED RELEASES .......................................................................................................
8 7.0 REACTOR COOLANT ACTIVITY .............................................................................................
8 8.0 SITE R A D IA TION D O SE ..........................................................................................................
9 9.0 OFFSITE DOSE CALCULATION MANUAL (ODCM) REVISIONS
......................................
10 10.0 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS
......................................................
10 11.0 PROCESS CONTROL PROGRAM REVISIONS
......................................................................
10 12.0 INOPERABLE EFFLUENT MONITORING INSTRUMENTATION
......................................
10 13.0 NEI's INDUSTRY INITIATIVE ON GROUND WATER SAMPLING ....................................
10 14.0 ANNUAL LAND-CENSUS CHANGES ....................................................................................
10 UNIT 3 REG GUIDE 1.21 TABLES ...............................................................................
11 UNIT 4 REG GUIDE 1.21 TABLES ...............................................................................
28 SITE DOSE REG GUIDE 1.21 TABLES ..........................................................................
47 ATTACHMENT A, SOLID WASTE AND IRRADIATED FUEL SHIPMENTS
...............................
65 A T T A C H M EN T B , O D C M .....................................................................................................................
68 2 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 EXECUTIVE
SUMMARY
Gaseous and liquid effluent releases were quantified, and calculations performed in accordance with the Off-Site Dose Calculation Manual (ODCM) for the period of release of January 2013 through December 2013. The derived dose calculations to the public were a small fraction of the limits allowed in the ODCM. No single liquid or gaseous discharge exceeded the limits set forth in the ODCM. The following information includes the required information for the Annual Radioactive Effluent Release Report for Turkey Point Units 3, 4, and site (combined) as outlined in Regulatory Guide 1.21 Revision 2.1.0 REGULATORY LIMITS 1.1 Liquid Effluent (a) The concentration of radioactive material released in liquid effluents to unrestricted areas shall not exceed ten times the concentration specified in lOCFR20 Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained gases. For dissolved or entrained noble gases, the concentration shall not exceed 2.OE-04 micro-curies per milliliter total activity.(b) The dose or dose commitment per reactor to a member of the public from any radioactive materials in liquid effluents released to unrestricted areas shall be limited as follows:> During any calendar quarter, to less than or equal to 1.5 mrem to the total body and less than or equal to 5 mrem to any organ.> During any calendar year, to less than or equal to 3.0 mrem to the total body and less than or equal to 10 mrem to any organ.1.2 Gaseous Effluent (a) The dose rate due to radioactive materials released in gaseous effluent from the site to areas at and beyond the site boundary shall be limited to the following:
> Less than or equal to 500 mrem per year to the total body and less than or equal to 3000 mrem per year to the skin due to noble gases.> Less than or equal to 1500 mrem per year to any organ due to 1-13 1, 1-133, tritium, and for all radioactive materials in particulate form with half-lives greater than 8 days.(b) The air dose per reactor to areas at and beyond the site boundary due to noble gases released in gaseous effluents shall be limited to: During any calendar quarter, to less than or equal to 5 mrad for gamma radiation and less than or equal to 10 mrad for beta radiation.
> During any calendar year, to less than or equal to 10 mrad for gamma radiation and less than or equal to 20 mrad for beta radiation.
3 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 (c) The dose per reactor to a member of the public, due to 1-131, 1-133, Tritium, Carbon-14 and all radionuclides in particulate form with half-lives greater than 8 days in gaseous effluent released to areas at and beyond the site boundary shall not exceed 7.5 mrem to any organ during any calendar quarter and shall not exceed 15 mrem to any organ during any calendar year. Carbon- 14 dose was calculated using the guidance of Regulatory Guide 1.109, Calculations of Annual Doses to Man from Routine Releases of Reactor Effluents for the purpose of Evaluation Compliance with 1OCFR Part 50, Appendix 1, Rev I, Oct 1977.1.3 Limits of Total Dose to Members of the Public (a) The annual (calendar year) dose or dose commitment to any MEMBER OF THE PUBLIC due to releases of radioactivity and to radiation from uranium fuel cycle sources shall be limited to less than or equal to 25 mrems to the whole body or any organ, except the thyroid, which shall be limited to less than or equal to 75 mrems.2.0 EFFLUENT CONCENTRATION Water: In accordance with 1OCFR20, Appendix B, Table 2, Column 2, and for entrained or dissolved noble gases as described in 1.1 .a of this report.Air : Release concentrations are limited to dose rate limits described in 1.2 of this report.3.0 AVERAGE ENERGY The average energy of fission and activation gases in effluents is not applicable.
4.0 MEASUREMENTS AND APPROXIMATIONS OF TOTAL ACTIVITY All liquid and airborne discharges to the environment during this period were analyzed in accordance with Technical Specification requirements.
The minimum frequency of analysis as required by Regulatory Guide 1.21 was met or exceeded.4.1 Liquid Effluents Aliquots of representative pre-release samples, from the waste disposal system, were isotopically analyzed for gamma emitting isotopes on a multichannel analyzer.Frequent periodic sampling and analysis were used to determine if radioactivity was being released via the steam generator blowdown system and the storm drain system.Monthly and quarterly composite samples for the waste disposal system were prepared to give proportional weight to each liquid release made during the designated period of accumulation.
The monthly composite was analyzed for tritium and gross alpha radioactivity.
Tritium was determined by use of liquid scintillation techniques, and gross alpha radioactivity was determined 4
TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 by use of a solid state scintillation system. The quarterly composite was analyzed for Sr-89, Sr-90, Ni-63, and Fe-55 by chemical separation.
Canal Evaporation dose calculations were done in accordance with the ODCM Control 2.5 as return/reuse of previous discharged radioactive effluents.
This is calculated as a continuous release as gas evaporation.
All radioactivity concentrations determined from sample analysis of a pre-release composite were multiplied by the total represented volume of the liquid waste released to determine the total quantity of each isotope and of gross alpha activity released during the compositing period.Aliquots of representative samples from the waste disposal system were analyzed on a pre-release basis by gamma spectral analysis.
The resulting isotope concentrations were multiplied by the total volume released in order to estimate the total dissolved gases released.The liquid waste treatment system is shared by both units at the site and generally all liquid releases are allocated on a 50/50 basis to each unit respectively.
There were no continuous releases above the lower limit of detection for Unit 3 or 4 via normal release paths.4.2 Gaseous Effluents Airborne releases to the atmosphere occurred from the following sources:-Gas Decay Tanks-Containment Purges-RWST via vent line-Condenser Off-gas-Releases incidental to operation of the plant.-Canal Evaporation
-Containment Hatch (when open during outages)The techniques employed in determining the radioactivity in airborne releases are: a) Gamma spectral analysis for fission and activation gases, b) Removal of particulate material by filtration and subsequent gamma spectral analysis, Sr-89, Sr-90 determination, and gross alpha determination, c) Absorption of halogen radionuclides on a charcoal filter and subsequent gamma spectral analysis, and d) Analysis of water vapor in a gas sample for tritium using liquid scintillation techniques.
e) Carbon-14 curies were calculated using the guidance of "Estimation of Carbon-14 in Nuclear Power Plant Gaseous Effluents", TR 1021106, EPRI, Palo Alto, CA:2010 All gaseous releases from the plant which were not accounted for by the above methods were conservatively estimated as curies of Xe- 133 by use of the SPING-4 radiation monitors and the 5 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Plant Vent process monitor data using the current calibration curve for that process monitor. This method was not used this reporting period.Both units share portions of the gaseous waste treatment system and generally all gaseous releases from the shared system are allocated on a 50/50 basis to each unit.Meteorological data for the period January 2013 through December 2013, in the form of Joint Frequency Distribution Tables, are maintained on site.4.3 Estimation of Errors a) Sampling Error The error associated with volume measurement devices, flow measuring devices, etc., based on calibration data and design tolerances has been conservatively estimated to be collectively less than + 10%.b) Analytical Error Our Q.C. Cross-Check Program involves counting unknown samples provided by an independent external lab. The errors associated with our analysis of these unknown samples, reported to us by the independent lab, were used as the basis for deriving the following analytical error terms: NUCLIDE TYPE AVERAGE ERROR MAXIMUM ERROR Liquid +/- 1.97% +/- 2.63%Gaseous +/- 2.20% +/- 3.07%4.4 Radioactive Waste Treatment System Changes a) Sampling Error The error associated with volume measurement devices, flow measuring devices, etc., based on calibration data and design tolerances has been conservatively estimated to be collectively less than + 10%.5.0 BATCH RELEASES Batch releases are summarized in the attached tables for Unit 3, Unit 4, and Site.6 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 6.0 UNPLANNED RELEASES 6.1 Liqiuid There was one unplanned release this period. On 9/30/13 approximately 80 gallons of Unit 4 RWST water was lost. The spill happened due to an improperly installed drain/seal water line on the Unit 4 Refueling Water Purification Pump (4P209) from maintenance activity.
The spill was stopped by operations by closing the suction valve to the Unit 4 Refueling Water Purification Pump. An undetermined amount of the 80 gallons was spilled on the gravel area surrounding the Unit 4 RWST, while the rest of the water went via the drain to the #1 Waste Holdup Tank (WHT). The area was remediated within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> bringing the soil samples to within acceptable levels based on historical analysis.The contaminated dirt was placed in drums. An assessment was made based on the sites hydrology and spill location to monitor the wells most likely to capture any contaminants which made it to ground water. All well samples have been within the limits of the Offsite Dose Calculation Manual, Table 5.1-2, Reporting Levels for Radioactivity Concentrations in Environmental Samples. Monitoring continues on a monthly basis.Dose to the public was calculated as a gaseous release of all constituents for conservatism.
6.2 Gaseous There were no unplanned gaseous releases this period.7.0 REACTOR COOLANT ACTIVITY 7.1 Unit 3 Reactor coolant activity limits of 0.25 laCi/gram Dose Equivalent 1-131 and 447.7 PtCi/gram Dose Equivalent Xe-133 were not exceeded during this reporting period.7.2 Unit 4 Reactor coolant activity limits of 0.25 ptCi/gram Dose Equivalent 1-131 and 447.7 ýICi/gram Dose Equivalent Xe- 133 were not exceeded during this reporting period.7 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 8.0 SITE RADIATION DOSE The assessment of radiation dose from radioactive effluents to the general public due to their activities inside the site boundary assumes a visitor was at the child development center/fitness center for ten hours a day, five days each week for fifty weeks of the year, receiving exposure from both Unit 3 and Unit 4 at Turkey Point. The child development center/fitness center is located approximately 1.75 miles WNW of the plant. Specific activities used in these calculations are the sum of the activities listed in the attached Unit 3 and Unit 4 Reg. Guide 1.21 tables. All dose to the public where a fraction of the limits and dose were maintained as low as reasonably achievable.
The total calculated off site dose to the public is summarized in the following table A-5 per EPA 40 CFR 190 "Individual in the Unrestricted Area": Rea. Guide 1.21 Table A-5 Total Dose Visitor Dose Total Dose (mrem)Visitor Dose Limit (mrem)(mrem)Percent of Limit (%)Percent of Limit (%)Bone (mrem) 2.03 E -02 1.72 E-02 25 8.11 E -02 6.89 E-02 Liver (mrem) 2.03 E -02 1.72 E-02 25 8.11 E -02 6.89 E-02 Thyroid (mrem) 2.03 E -02 1.72 E-02 75 2.70 E -02 2.30 E-02 Kidney (mrem) 3.23 E -03 2.75 E-03 25 1.29 E -02 1.10 E-02 Luniz (mrem) 2.03 E -02 1.72 E-02 25 8.11 E -02 6.89 E-02 GI-LLI (mrem) 2.03 E -02 1.72 E-02 25 8.11 E -02 6.89 E-02 Skin (mrem) 2.03 E -02 1.72 E-02 25 8.11 E -02 6.89 E-02 Total Body (mrem) 2.03 E -02 1.72 E-02 25 8.11 E -02 6.89 E-02 Gamma Air Dose 2.37 E -06 4.00 E-07 10 2.37 E -05 4.004 E-06 Beta Air Dose 5.19 E -06 8.77 E-07 20 2.60 E-05 4.386 E-06 Noble Gas Total 2.09 E -06 3.54 E-07 500 4.19 E-07 7.074 E-08 Noble Gas Skin Air 4.80 E -06 8.11 E-07 3000 1.60 E-07 2.704 E-08 8 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 9.0 OFFSITE DOSE CALCULATION MANUAL (ODCM) REVISIONS The ODCM was reviewed and revised in 2013. A copy is attached as Attachment B.10.0 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS No irradiated fuel shipments or irradiated component shipments were made from the site.Common solid waste from Turkey Point Units 3 and 4 was shipped jointly. A summation of these shipments is given in Attachment A of this report (Reg. Guide 1.21 Table A-3).11.0 PROCESS CONTROL PROGRAM REVISIONS There were no revisions to the Process Control Program during this reporting period.12.0 INOPERABLE EFFLUENT MONITORING INSTRUMENTATION There was no inoperable effluent monitoring instrumentation requiring report during this period.13.0 NEI's INDUSTRY INITIATIVE ON GROUND WATER SAMPLING In 2013 as part of the Industry Initiative on Groundwater Sampling, wells on site and adjacent to the site were sampled for tritium. The tritium results were from <MDA to 11,200 pico curies per liter. Selected wells which met the criteria stipulated in the ODCM were analyzed for hard to detect beta emitters (Fe-59, Ni-63, Sr-89/90, and alpha). All results were less than the limits of the Offsite Dose Calculation Manual, Table 5.1-2, Reporting Levels for Radioactivity Concentrations in Environmental Samples. The results are reported in the Annual Radiological Environmental Operating Report. The five-year review of the Groundwater Sampling Program was conducted in July 2013 indicating the program meets all NEI 07-07 requirements.
The Site Conceptual Model was updated in June 2013 meeting the five-year requirement.
Two new shallow wells were recommended by the Unit 3 and 4 Steam Generator Blowdown.
The Engineering Change Request has been processed for planning and execution.
14.0 ANNUAL LAND-USE CENSUS CHANGES In 2013 the land census conducted revealed no changes with in 5 miles of the plant. The land census is filed in the Annual Radiological Environmental Operating Report.9 Unit 3 Reg. Guide 1.21 Tables: 1. Table A-i: Gaseous Effluents
-Summation of all Releases 2. Table A-1A: Gaseous Effluents
-Ground Level Release -Batch Mode 3. Table A-1B: Gaseous Effluents
-Ground Level Release -Continuous Mode 4. Table A-IC: Gaseous Effluents
-Elevated Release -Batch Mode 5. Table A-iD: Gaseous Effluents
-Elevated Release -Continuous Mode 6. Table A-1E: Gaseous Effluents
-Mixed Mode Release -Batch Mode 7. Table A-IF: Gaseous Effluents
-Mixed Mode Release -Continuous Mode 8. Table A-2: Liquid Effluents
-Summation of all Releases 9. Table A-2A: Liquid Effluents
-Batch Mode 10. Table A-2B: Liquid Effluents
-Continuous Mode 11. Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Dose to a member of the public due to Liquid Release 12. Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Air Dose Due to Gaseous Releases 13. Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Dose due to Radioiodines, Tritium, and Particulates in Gaseous Releases 14. Liquid and Gas Batch Release Summary 15. Table 6: Liquid and Gas Abnormal Release Summary I1-5. 10 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-i: Gaseous Effluents
-Summation of all Releases Unit: 3 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases 1. Total Release C0 1.36E-01 7.04E-04 9.23E-04 4.24E-03 1.41E-01 2. Average Release Rate for Period uCi/s 1.74E-02 8.95E-05 1.16E-04 5.34E-04 4.49E-03 3. Percent of Limit % N/A N/A N/A N/A N/A B. Iodines and Halogens 1. Total Release Ci O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 2. Average Release Rate for Period uCi/s 0.00E+O 0 0.OOE+00 0.0 O.OOE+00 O.OOE+00 O.OOE+00 3. Percent of Limit % N/A N/A N/A N/A N/A C Particulates
- 1. Total Release Ci O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 2. Average Release Rate for Period uCi/s O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 3. Percent of Limit % NIA NIA N/A N/A N/A D. Tritium 1. Total Release Q 1.12E+00 1.51E+00 4.22E-01 1.16E-01 3.16E+00 2. Average Release Rate for Period uCl/s 1.44E-01 1.92E-01 5.30E-02 1.46E-02 1.OOE-01 3. Percent of Limit % N/A NIA N/A NIA N/A E. Gross Alpha 1. Total Release Q O.OE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.0OE+00 F. Carbon-14 1. Total Release 0 1.93E+00 1.93E+00 1.93E+00 1.93E+00 7.73E+00 2. Average Release Rate for Period uCi/s 2.48E-01 2.46E-01 2.43E-01 2.43E-01 2.45E-01 3. Percent of Limit % N/A NIA N/A N/A NIA II TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-1A: Gaseous Effluents
-Ground Level Release -Batch Mode Unit: 3 Starting:
1-1an-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases No Nudides Found ai O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 B. Iodines and Halogens No Nudides Found C. Particulates No Nuclides Found D. Tritium No Nudides Found E. Gross Alpha No Nudides Found F. Carbon-14 No Nuclides Found ai 0 Ci Ci C, O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+OC O.OOE-i-O O.O0E+00 0.0{)E+00 O.OOE+OO O.OOE+OO O.COE+0O 0.a0E+00 0.00E+00 O.0OE+00 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 12 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-IB: Gaseous Effluents
-Ground Level Release -Continuous Mode Unit: 3 Nuclides Released A. Fission and Activation Gases No Nudides Found B. lodines and Halogens No Nudides Found C. Particulates No Nudides Found D. Trtium No Nudides Found E. Gross Alpha No Nudides Found F. Carbon-14 No Nudides Found Starting:
1-Jan-2013 Ending: 31-Dec-2013 Continuous Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 0 O.OOE+O0 OOOE+O0 O.OOE+O0 Ci O.OOE+ao O.OOE+O0 O.OOE+O0 C O.OOE+O0 O.OOE+O0 O.OOE+O0 Ci O.OOE+O0 O.OOE+OO O.OOE+00 Ci O.OOE+OO O.OOE+O0 O.OOE+OO Ci O.OOE+O0 O.OOE+O0 O.OOE+O0 4TH Quarter O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+OO Annual O.OOE+O0 O.OOE+O0 O.OOE+OO O.OOE+OO O.OOE+00 O.OOE+00 13 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-1C: Gaseous Effluents
-Elevated Release -Batch Mode Unit: 3 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases No Nuclides Found Ci O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 B. Iodines and Halogens No Nuclides Found Ci O.OOE+OO O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 C. Particulates No Nuclides Found Ci O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+OO O.OOE+O0 D. Tritum No Nuclides Found Ci O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 E. Gross Alpha No Nudides Found Ci O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+OO O.OOE+O0 F. Carbon-14 No Nuclides Found Ci O.OOE+O0 O.OOE+00 O.OOE+O0 O.OOE+O0 O.OOE+O0 14 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTWE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-1D: Gaseous Effluents
-Elevated Release -Continuous Mode Unit: 3 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Continuous Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases No Nuclides Found Ci O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 B. lodines and Halogens No Nuclides Found Ci O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 C. Particulates No Nudides Found Ci O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 D. Tritium No Nuclides Found 0 O.OOE+O0 O.OOE+O0 (.OOE+O0 O.OOE+O0 O.OOE-00O0 E. Gross Alpha No Nuclides Found Ci O.OOE+O0 O.OOE+O0 O.OOE+OO O.OOE+O0 O.OOE+O0 F. Carbon-14 No Nuclides Found Ci O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 15 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-1E: Gaseous Effluents
-Mixed Mode Release -Batch Mode Unit: 3 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released A. Fission and Activation Gases Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Ar-41 Kr-85m Kr-87 Kr-88 Xe-131m Xe-133m Xe-133 Xe-135 Total For Period Ci Ci a Q a Ci C, C', Ci 1.29E-04 1.11E-04 5.59E-07 2.95E-05 0.OOE+00 1.01E-03 1.21E-01 1.31E-02 1..36E-01 O.O0E+00 O.OOE+0O 0,OOE+00 0.00E4-00 O.DOE+O0 0.OOEO00 7.02E-04 1.46E-06 7.04E-04 0.OOE+00 0.OOE+00 0.OOE+O0 0.00E+00 2.94E-05 0.OOE+OO 8.93E-04 1.32E-16 9.23E-04 1.33E-05 7.32E-06 2.67E-07 6.21E-06 O.OOE+00 1.97E-05 3.88E-03 3.16E-04 4.24E-03 1.42E-04 1.19E-04 8.26E-07 3.57E-05 2.94E-05 1 .03E-03 1.27E-01 1 .34E-02 1.41E-01 B. lodines and Halogens No Nuclides Found C. Particulates No Nuclides Found D. Tritium No Nuclides Found Ci Ci 0 01 Ci O.OOE+O0 0.OOE+00 O.00E+00 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+/-00 0.OOE+00 0.OOE+00 0.OOE 400 O.00E+00 O.OOE+/-00 G.OOE+00 0.OOE+00 O.OOE+00 0.OOE+O0 O.OOE-40O 0.OOE+O0 0.OOE+00 O.OOE+O0 0.0Or:+00 O.OOE+0O O.00E+00 O.OOE+00 O.00E+00 E. Gross Alpha No Nuclides Found F. Carbon-14 No Nuclides Found 16 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-1F: Gaseous Effluents
-Mixed Mode Release -Continuous Mode Unit: 3 Starting:
l-Jan-2013 Ending: 31-Dec-2013 Continuous Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases No Nuclides Found Ci O.OOE+O0 O.OOE+OO o.OOE+00 O.OOE+O0 O.OOE+O0 B. Iodines and Halogens No Nuclides Found C. Particulates No Nuclides Found D. Tritium H-3 E. Gross Alpha No Nuclides Found F. Carbon-14 C-14 Ci Ci Ci O.OOE+OQ O.JOE+OO 1.12E+00 O.OOE+OO 1.93E+00 O.OOE+OO O.OOE+OO 1.51E+00 c.ooE+ao 1.93E+00 O.OOE+OO O.OOE-i-O 4.22E-01 O.OOE+00 1.93E+00 O.OOE+0O O.OOE+OO 1.16E-01 O.OOE+OO 1.93E+00 O.OOE+OO O.OOE-i-O 3. 16E+00 O.OOE+OO 7.73E+00 17 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-2: Liquid Effluents
-Summation of all Releases Unit: 3 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Products 1. Total Release Ci 8.99E-03 1.10E-02 3.58E-03 1.12E-02 3.48E-02 2. Average Concentration uCi/mL 4.98E-11 3.31E-11 9.33E-12 3.81E-11 3.21E-11 3. Percent of Limit % 7.11 E-07 4.73E-05 1.33E-05 5.44E-05 4.58E-05 B. Tritium 1. Total Release Ci 8.42E+01 7.70E+01 1.37E+01 3.50E+01 2.10E+02 2. Average Concentration uCi mL 4.66E-07 2.31E-07 3.59E-08 1.19E-07 1.94E-07 3. Percent of Limit % 4.66E-03 2.31 E-03 3.59E-04 1.19E-03 1.94E-03 C. Dissolved and Entrained Gases 1. Total Release Ci 4.68E-04 O.OOE+00 O.OOE+00 0.00E+00 4.68E-04 2. Average Concentration uCi/mL 2.59E-12 O.OOE+O0 O.OOE+O0 O.OOE+O0 4.31E-13 3. Percent of Umit % 1.30E-06 O.OOE+00 O.OOE+00 O.OOE+00 2.16E-07 D. Gross Alpha Activity 1. Total Release Ci O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 2. Average Concentration uCi/mL O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 E. Primary Liquid Release Volume 1. Total Release Liters 6.09E+05 4.45E+05 2.19E+05 1.59E+05 1.43E+06 F. Dilution Volume 1. Total Release Liters 1,80E+11 3.33E+11 3.83E+11 2.95E+11 1.08E+12 18 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-2A: Liquid Effluents
-Batch Mode Unit: 3 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released A. Fission and Activation Products Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Na-24 Cr-51 Mn-54 Fe-55 Fe-59 Co-57 Co-58 Co-60 Ni-63 Zn-65 Br-82 Nb-95 Nb-97 Ag-l10m Sn-117m Sb-122 Sb-124 Sb-125 1-131 1-133 1-134 Cs-134 Cs-137 Total For Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Cl Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci O.00E+00 2.33E-04 O.OOE+0O 1,76E-03 6.27E-06 O.OOE+0O 1.31E-03 5.78E-05 1.95E-03 O.OOE-+OO O.OOE+O0 4.06E-06 O.OOE+OO 2,52E-05 2.29E-06 O.OOE+00 3.16E-04 3. 2E-03 1.70E-06 3.86E-06 1.5 1E-06 4.39E-06 1.90E-04 8.99E-03 2.10E-05 O.OOE+OO 6.56E-05 7.96E-04 O.OCE+OO 2.08E-06 5.17E-03 2.57E-04 1.76E-03 O.OOE+OO 1.62E-06 3.07E-06 O.OOE+00 O.OOE+OO 5.03E-07 1 .35E-06 1 .86E-05 1 .19E-03 1.12E-05 4.46E-06 O.OCE+OO 1 .64E-04 1.54E-03 1.10E-02 O.O0E+00 O.OOE+00 7.96E-06 2.41E-04 C.OOE+OO 1.76E-06 7.26 E-04 9.57E-05 1.46E-03 O.OOE+OO 0. 00E+ 00 O.OOE-*00 0.OOE+O0 0.OOE+O0 O.OOE-i-O0 0.OOE+0O 0.OOE+00 4.50E-04 Q.00E4-00 0.OOE+00 0.OOE+O0 4.71lE-05 5.45E-04 3.58E-0 0.OOE+00 0.OOE+O00 1.58E-04 5SIE-04 O.OOE+i00 1 .84E-105 1.18E--03 3.53E-04 6. 15E-03 4. 12E-06 O.OOE+00 0.OOE+00 1 .82E-06 0.OOE+00 0.00E+00 0.OOE+00 O.OOE+00 3.43E-04 5.60E-06 3.04E-06 0.OOE+O0 1.95E-04 2.26E-03 1.12E-02 2.10E-05 2.33E-G4 2.32E-04 3.35E-03 6.27E-06 2.23 E-05 8.39E-03 7.63 E-04 1.13E-02 4. 12E-06 1.62E-06 7.13E-06 1.82E-06 2.52E-05 2.79E-06 1.35E-06 3.35E-04 5.10E-03 1.85E-05 1. 14E-05 1.51E-06 4. 10E-04 4.54E-03 3.48E-02 19 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-2A: Liquid Effluents
-Batch Mode Unit: 3 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released B. Tritium Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual H-3 0 8.42E+01 7.70E+01 1.37E+01 3.50E+01 2.10E+02 C. Dissolved and Entrained Gases Kr-85 Xe-133 Ci 0i Ci 4.66E-04 1.50E-06 4.68E-04 O-00E+00 o.OOE+00 0.00 E+00 O.QOE+00 O.00E+00O 0.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 4.66 E-04 1.50E-06 4.68E-04 ToNul For Period D. Gross Alpha Activity No Nudides Found Ca O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 20 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-2B: Liquid Effluents
-Continuous Mode Unit: 3 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Continuous Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Nuclides Released A. Fission and Activation Products No Nudides Found B. Tritium C0 No Nudides Found C. Dissolved and Entrained Gases No Nudides Found D. Gross Alpha Activity No Nudides Found 0 ai O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+OO O.OOE+OO O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+O0 o.aoE+oo O.OOE+OO O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 C, O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 21 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Dose to a member of the public due to Liquid Release Unit: 3 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Ogan Dose Bone Limit Percent of Limit Units mRem mRem 1ST Quarter 2.16E-05 5.000 0.000 2ND Quarter 5.30E-05 5.000 0.001 3RD Quarter 1.81E-05 5.000 0.000 4TH Quarter 6.56E-05 5.000 0.001 Annual 1.58E-04 10.000 0.002 Liver mRem 2.16E-05 5.30E-05 1.81E-05 6.56E-05 1.58E-04 Limit mRem 5.000 5.000 5.000 5.000 10.000 Percent of Limit % 0.000 0.001 0.000 0.001 0.002 Total Body mRem 2.16E-05 5.30E-05 1.81E-05 6.56E-05 1.58E-04 Umit mRem 1.500 1.500 1.500 1.500 3.000 Percent of Limit 00 0.001 0.004 0.001 0.004 0.005 Thyroid mRem 2.16E-05 5.30E-05 1.81E-05 6.56E-05 1.58E-04 Limit mRem 5.000 5.000 5.000 5.000 10.000 Percent of Limit % 0.000 0.001 0.000 0.001 0.002 Kidney mRem 2.16E-05 5.30E-05 1.81E-05 6.56E-05 1.58E-04 Limit mRern 5.000 5.000 5.000 5.000 10,000 Percent of Limit % 0.000 0.001 0.000 0.001 0.002 Lung mRem 2.16E-05 5.30E-05 1.81E-O5 6.56E-05 1.58E-04 Limit mRem 5.000 5.000 5.000 5.000 10.000 Percent of Limit % 0.000 0.001 0.000 0.001 0.002 GI-Ui mRem 2.16E-05 5.30E-05 1.81E-05 6.56E-05 1.58E-Oq Limit mRem 5.000 5.000 5,000 5.000 10.000 Percent of Limit %a 0.000 0.001 0.000 0.001 0.002 22 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Dose to a member of the public due to Liquid Release Unit: 3 Starting:
1-3an-2013 Ending: 31-Dec-2013 Ogan Dose Sijn Urdts 1ST Quaiter 2ND Quarter 3RD Quarter 4TH Quarter Annual rnRe- 2.47E-05 &17E-05 2.1!E-05 765E-05 1.84E-04 Uffrn perce-it df Lhiit fnP,, 5-OW 0.00D 5.0c3 0.001 50000 0.0,00 5.C03 O.002 10-03Do 0-032 23 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Air Dose Due to Gaseous Releases Unit: 3 Starting:
1-Jan-2013 Ending: 31-Dec-2013 NG Dose Gamma Air Limit Percent of Limit Units mRad mRad 1ST Quarter 1.39E-06 5 2.78E-05 2ND Quarter 5.01E-09 5 1 .OOE-07 3RD Quarter 6.39E-09 5 1.28E-07 4TH Quarter 4.25E-08 5 8.50E-07 Annual 1.44E-06 10 1.44E-05 Beta Air mRad 3.23E-06 1.48E-08 1.94E-08 9.91E-08 3.36E-06 Limit mRad 10 10 10 10 20 Percent of Limit % 3.23E-05 1.48E-07 1.94E-07 9.91 E-07 1.68E-05 NG Total Body mRem 1.22E-06 4.18E-09 5.30E-09 3.71E-08 1.26E-06 Limit mRem N/A N/A N/A N/A 500 Percent of Limit % N/A N/A N/A N/A 2.52E-07 NG Skin mRem 2.80E-06 9.90E-09 1.28E-08 8.43E-08 2.91E-06 Limit mRem N/A N/A N/A N/A 3000 Percent of Limit 0 NIA N/A N/A N/A 9.70E-08 24 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Dose due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: 3 Starting:
1-3an-2013 Ending: 31-Dec-2013 Organ Dose Bone Limit Percent of Limit Units mRem mRem 1ST Quarter 4.97E-03 7.500 0.066 2ND Quarter 4.98E-03 7.500 0.066 3RD Quarter 4.98E-03 7.500 0.066 4TH Quarter 4,98E-03 7.500 0.066 Annual 1.99E-02 15.000 0.133 Liver mRem 4.99E-03 4.99E-03 4.98E-03 4.98E-03 1.99E-02 Limit mRem 7.500 7.500 7.500 7.500 15.000 Percent of Limit % 0.066 0.067 0.066 0.066 0.133 Total Body mRem 4.99E-03 4.99E-03 4.98E-03 4.98E-03 1.99E-02 Limit mRem N/A N/A N/A N/A N/A Percent of Limit % N/A N/A N/A N/A N/A Thyroid mRem 4.99E-03 4.99E-03 4.98E-03 4.98E-03 1.99E-02 Limit mRem 7.500 7.500 7.500 7.500 15.000 Percent of Limit % 0,066 0.067 0.066 0.066 0.133 Kidney mRem 7.19E-04 7.21E-04 7.15E-04 7.14E-04 2.87E-03 Limit mRem 7.500 7.500 7.500 7.500 15.000 Percent of Limit % 0.010 0.010 0.010 0.010 0.019 Lung mRem 4.99E-03 4.99E-03 4.98E-03 4.98E-03 1.99E-02 Limit mRem 7.500 7.500 7.500 7.500 15.000 Percent of Limit % 0.066 0.067 0.066 0.066 0.133 GI-Ui mRem 4.99E-03 4,99E-03 4.98E-03 4.98E-03 1.99E-02 Limit mRem 7.500 7.500 7.500 7.500 15.000 Percent of Limit % 0.066 0.067 0.066 0.066 0.133 25 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Liquid and Gas Batch Release Summary Unit: 3 Starting:
1-Jan-2013 Ending: 31-Dec-2013 A. Liquid Batch Release Totals 1. Number of Batch Releases 2. Total duration of batch releases 3. Maximum batch release duration 4. Average batch release duration 5. Minimum batch release duration B. Gas Batch Release Totals 1. Number of Batch Releases 2. Total duration of batch releases 3. Maximum batch release duration Units 1st Quarter 45 min 4.75E+03 min 1.34E+02 min 1.06E+02 min 9.OOE+01 Units 1st Quarter 18 2nd Quarter 34 3.37E+03 1.ZOE+02 9,92E+01 8.60E+01 2nd Quarter 4 1.62E+02 4.50E+01 4.05E+01 3.80E+01 3rd Quarter 17 1.67E+03 1.23E+02 9.85E+01 7.00E+01 3rd Quarter 2 6.90E+01 3.50E+01 3.45E+01 3.40E+01 4th Quarter 12 1.16E+03 1.05E+02 9.65E+01 7.OOE+01 4th Quarter 3 1.26E+02 4.90E+01 4.20E+01 3.10E+01 Year Totals 108 1.10E+04 1.34E+02 1.01E+02 7.OOE+01 Year Totals 27 1.40E+04 1.30E+04 5.20E+02 3.00E+01 min min min min 1.37E+*04 1.30E+04 7.60E+02 3.OOE+01 4. Average batch release duration 5. Minimum batch release duration 26 A. Uquid Abnormal Releas L Number of Abnormal Relea 2. Total Activity of abnomial B. Gas Abnormal Release 1. Number of Abnormal Rele, 2. Total Activity of abnormal TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table 6: Liquid and Gas Abnormal Release Summary Unit: 3 Starting:
1-Jan-2013 Ending: 31-Dec-2013 se Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4t1 ases 0 0 0 retse 0 0.OOE+O0 O.OOE+O0 O.OOE+00 0.Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th 35es 0 0 0 releases Ci O.OOE+O0 O.OOE+00 O.OOE+00 0.Quarter 0 OOE+OD Quarter 0 OOE+00 Year Totals 0 0.OOE+00 Year Totals 0 O.OOE+-0 27 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Unit 4 Reg. Guide 1.21 Tables: 1. Table A-i: Gaseous Effluents
-Summation of all Releases 2. Table A-1A: Gaseous Effluents
-Ground Level Release -Batch Mode 3. Table A-1B: Gaseous Effluents
-Ground Level Release -Continuous Mode 4. Table A-iC: Gaseous Effluents
-Elevated Release -Batch Mode 5. Table A-1D: Gaseous Effluents
-Elevated Release -Continuous Mode 6. Table A-1E: Gaseous Effluents
-Mixed Mode Release -Batch Mode 7. Table A-iF: Gaseous Effluents
-Mixed Mode Release -Continuous Mode 8. Table A-2: Liquid Effluents
-Summation of all Releases 9. Table A-2A: Liquid Effluents
-Batch Mode 10. Table A-2B: Liquid Effluents
-Continuous Mode 11. Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Dose to a member of the public due to Liquid Release 12. Table A-4: Dose Assessments 10 CFR Part 50, Appendix 1: Air Dose Due to Gaseous Releases 13. Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Dose due to Radioiodines, Tritium, and Particulates in Gaseous Releases 14. Liquid and Gas Batch Release Summary 15. Table 6: Liquid and Gas Abnormal Release Summary 28 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-i: Gaseous Effluents
-Summation of all Releases Unit: 4 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Total Release Units IST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases 1. Total Release Ci 6.25E-02 7.04E-04 9.2-3E-04 4.24E-03 6.84E-02 2. Average Release Rate for Period uCi/s 8.04E-03 8.95E-05 1.16E-04 5.34E-04 2.17E-03 3. Percent of Limit % N/A N/A N/A N/A N/A B. lodines and Halogens 1. Total Release a O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 2. Average Release Rate for Period uCi/s 0.00E+00 O.OOE+0O O.OOE+00 0.00E+00 0.00E+00 3. Percent of Limit % N/A N/A N/A N/A N/A C. Particulates
- 1. Total Release Ci 8.42E-05 0.00E+00 0.00E+00 2.58E-04 3.43E-04 2. Average Release Rate for Period uCi/s 1.08E-05 O.OOE+00 O.OOE+00 3.25E-05 1.09E-05 3. Percent of Limit % NIA NIA N/A N/A NIA D. Tritium 1. Total Release Ci 1.21E+00 1.09E+00 4.22E-01 3.15E-03 2.73E+00 2. Average Release Rate for Period uCi/s 1.56E-01 1.39E-01 5.30E-02 3.96E-04 8.65E-02 3. Percent of Umit % N/A NIA N/A NIA N/A E. Gross Alpha 1. Total Release a O.OOE+00 O.OOE+00 0.OOE+00 0.00E+00 O.0OE+00 F. Carbon-14 1. Total Release Ci 1.45E+00 1.45E+00 1.45E+00 1.45E+00 5.78E+O0 2. Average Release Rate for Period uCi/s 1.86E-01 1.84E-01 1.82E-01 1.82E-01 1.83E-01 3. Percent of Limit %29 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-1A: Gaseous Effluents
-Ground Level Release -Batch Mode Unit: 4 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released A. Fission and Activation Gases Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual No Nudides Found B. lodines and Halogens No Nudides Found Q 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 IJ.OOE+00 O.002+00 0.00E+00 0.00E+00 ai 0.OOE+00 C. Particulates Mn-S4 Co-58 CO-60 Zn-65 Sb-122 ci 0i 0i 0 0i Qi 0i C0 Ci 0.002+00 3.37E-07 3.53E-07 8.36E-05 0.00E+i00 0.002+00 0.00E+00 0.002+00 8.42E-05 0.OOE+00 0.00E+00 0.O0E+00 0.00E+00 0.00E+00 O.00E+00 0.00E+00 O.OOE+O0 O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 O.OOE+O0 1.59E-06 1.06E-05 2.34E-05 0.002+00 5.51E-07 1.09E-05 5.82E-06 Z.05E-04 2LSSE-04 1.59E-06 1.09E-05 2.38E-05 8.36E-05 5.51E-07 1.09E-05 5.82E-06 2.05E-04 3.43E-04 Sb-125 Cs-134 Cs-137 Total For Period D. Tritium H-3 E. Gross Alpha No Nudides Found F. Carbon-14 No Nuclides Found Ci Ci Ci 2187E-01 O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 3.15E-03 O.00E+00 O.OOE+00 2.91E-01 O.OOE+00 O.OOE+00 30 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-1B: Gaseous Effluents
-Ground Level Release -Continuous Mode Unit: 4 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Continuous Mode Nuclides Released A. Fission and Activation Gases No Nuclides Found B. Iodines and Halogens No Nuclides Found C. Particulates No Nuclides Found D. Tritium No Nuclides Found E. Gross Alpha No Nudides Found F. Carbon-14 No Nuclides Found Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter a a Ci a a ci 0.00E+00 O.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 0.00E+00 0.00E+00 O.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0,OOE+00 0.00E+00 0.00E+00 Annual 0.00E+00 0.00E+00 0.OOE+00 0.00E+00 0.00E+00 0.00E+00 31 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-1C: Gaseous Effluents
-Elevated Release -Batch Mode Unit: 4 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Nuclides Released A. Fission and Activation Gases No Nuclides Found B. Iodines and Halogens No Nudides Found C. Particulates No Nuclides Found D. Tritium No Nudlides Found E. Gross Alpha No Nuclides Found F. Carbon-14 No Nuclides Found Units 1ST Quarter a a 0.OOE+OO 0.OOE+O0 aj 0.00E+O0 2ND Quarter O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 Batch Mode 3RD Quarter O.OOE+0O O.OOE+00 O.OOE+0O 0.OOE+00 O.OOE+O0 O.OOE+0O 4TH Quarter O.OOE+0O O.OOE+0O O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+O0 Annual O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+00 Ci a 0.OOE+O0 0.OOE+00 O.OOE+O0 a 32 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-1D: Gaseous Effluents
-Elevated Release -Continuous Mode Unit: 4 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Continuous Mode Nuclides Released A. Fission and Activation Gases No Nuclides Found B. Iodines and Halogens No Nudides Found C. Particulates No Nuclides Found D. Tritium No Nuclides Found E. Gross Alpha No Nuclides Found F. Carbon-14 Units 1ST Quarter 0 Ci O.OOE+O0 O.OOE+O0 2ND Quarter O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 3RD Quarter O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 4TH Quarter O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 10 O.OOE+OO Annual o.0oE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+O0 Ci 0 ai O.OOE+OO O.OOE+00 O.OOE+OO No Nuclides Found O.OOE+O0 O.OOE+O0 O.OOE+00 33 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-1E: Gaseous Effluents
-Mixed Mode Release -Batch Mode Unit: 4 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released A. Fission and Activation Gases Ar-41 Kr-85m Kr-87 Kr-88 Xe-131m Xe-133m Xe-133 Xe-135 Total For Period B. lodines and Halogens No Nudides Found C. Particulates No Nuclides Found D. Tritium H-3 E. Gross Alpha No Nudides Found F. Carbon-14 No Nudides Found Units 0 a Ci Ci Ci 1ST Quarter 1 .29E-04 1.11E-04 5.59E-07 2.95E-05 O.OOE+OO 1.01E-03 4.81E-02 1.31E-02 6.25E-02 O.OOE+OO o.OOE+OO 1.55E-03 O.OOE+OO fl.OOE+DO 2ND Quarter 0.00E+00 O.OOE+0O O.OOE+OO O.OOE+0O O.OOE+OO O.OOE+0O 7.02E-04 1.46E-06 7.04E-04 o.aoE+oo O.OOE-i-O O.OOE+00 O.OOE+0O 0.OOE+00 3RD Quarter O.OOE+O0 O.OOE+00 O.OOE+O0 O.OOE+00 2.94E-05 o.ooE+00 8.93E-04 1.32E-16 9.23E-04 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 4TH Quarter 1.33E-05 7.32E-06 2.67E-07 6.21E-06 O.OOE+OO 1.97E-OS 3.88E-03 3.16E-04 4.24E-03 O.OOE+OO O.aoE+o0 O.COE+0O O.OOE+00 0.00E+00 Annual 1.42E-04 1.19E-04 8.26E-07 3,57E-05 2.94E-05 1 .03&-03 5.36E-02 1.34E-02 6.84E-02 O.OOE+200 O.OOE+OO 1.55E-03 a.OOE+00 O.AJOE+00 ai C, Qi a Ci 34 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-IF: Gaseous Effluents
-Mixed Mode Release -Continuous Mode Unit: 4 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Continuous Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases No Nuclides Found Ci O.OOE+OO O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 B. lodines and Halogens No Nudides Found C, O.OOE+OO O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 C. Particulates No Nuclides Found Ci O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 OOOE+O0 D. Tritium H-3 Ci 9.22E-01 1.09E+00 4.22E-01 O.OOE+O0 2.44E+O0 E. Gross Alpha No Nudides Found F. Carbon-14 C-14 Ci O.OOE+O0 O.OOE+O0 O.OOE+OO O.OOE+O0 O.00E+O0 Ci 1.45E+00 1.45E+00 1.45E+00 1.45E+00 5.78E+00 35 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-2: Liquid Effluents
-Summation of all Releases Unit: 4 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Products 1. Total Release Ci 8.99E-03 1.10E-02 3.58E-03 1.12E-02 3.48E-02 2. Average Concentration uCi/mL 4.98E-11 3.31E-11 9.33E-12 3.81E-11 3.21E-11 3. Percent of Umit % 7.11E-07 4.73E-05 1.33E-05 5.44E-05 4.58E-05 B. Tritium 1. Total Release Ca 8.42E+01 7.70E+01 1.37E+01 3.50E+01 2.10E+02 2. Average Concentration uCi/mL 4.66E-07 2.31E-07 3.59E-08 1.19E-07 1.94E-07 3. Percent of Limit % 4.66E-03 2.31 E-03 3.59E-04 1.19E-03 1.94E-03 C. Dissolved and Entrained Gases I. Total Release a 4.68E-04 O.OOE+00 O.0OE+00 O.OOE+00 4.68E-04 2. Average Concentration uCi/mL 2.59E-12 0.00E+00 O.OOE+00 O.OOE+00 4.31E-13 3. Percent of Limit % 1.30E-06 O.OOE+O0 O.OOE+O0 O.OOE+O0 2.16E-07 D. Gross Alpha Activity 1. Total Release a O.OE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 2. Average Concentration uCVmL O.OOE+00 O.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 E. Primary Uquid Release Volume 1. Total Release Liters 6.09E+05 4.45E+05 2.19E+05 1.59E+05 1.43E+06 F. Dilution Volume 1. Total Release Liters 1.80E+11 3.33E+11 3.83E+11 2.95E+11 1.08E+12 36 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-2A: Liquid Effluents
-Batch Mode Unit: 4 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released A. Fission and Activation Products Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Na-24 Cr-51 Mn-54 Fe-55 Fe-59 Co-57 Co-58 Co-60 Ni-63 Zn-65 Br-82 Nb-95 Nb-97 Ag-lr0m Sn-117m Sb-122 Sb-124 Sb-125 1-131 1-133 1-134 Cs-134 Cs-137 Total For Period 0 (a a a 0 0 0 ci ci Ci ci Ci Ci Ci Ci a Q a 0 Ci O.OOE+00 2.33E-04 O.OOE+/-O0 1.76E-03 6.27E-06 O.OOE+00 1.31E-03 5.78E-05 1.95E-03 O.OOE+O0 O.OOE+O0 4.06E-06 O.OOE+O0 2.52E-05 2.29E-06 O.OOE+O0 3.16E-04 3.12E-03 1.70E-06 3.86E-06 1.51E-06 4.39E-06 1.90E-04 8.99E-03 2. 10E-05 0.0OE+00 6.S6E-05 7.96E-04 O.OOE+i00 2.08E-06 5.1711-03 2,57E-04 1.76E-03 0.00E+00 1.62E-06 3.07E-G6 O.OOE+0O O.OOE+00 5.03E-07 1.35E-06 1.86E-05 1. 19E-03 1.12E-05 4.46E-06 0.OOE+00 1.64E-04 1.54E-03 1.10E-02 0.00 E+00 0.OOE+00 7.96E-06 2.41E-04 0.OOE+0O 1.76E-06 7.26 E-04 9.57E-05 1.46E-03 0.OOE+00 0.OOE+00 0.COE+OO 0.COE-40O 0.OOE+00 0.OOE+0O O.OOE+00 0.002+00 4.50E-04 0.00E+00 0.00E+00 0.002+00 4.71E-05 5.45E-04 3.58E-03 O.OOE+00 0.00E+00 1.58E-04 5.51E-04 O.OOE+00 1.84E-05 1.18E-03 3.53E-04 6.15E-03 4.12E-06 O.OOE00 O.OOE+00 1.82E-06 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 3.43E-04 5.60E-06 3.04E-06 O.OOE+00 1.95E-04 2.26E-03 1.12E-02 2.10E-05 2.33E-04 2.32E-04 3.35E-03 6.27E-06 2.23E-05 8.39E-03 7.63E-04 1.13E-02 4.12E-06 1.62E-06 7.13E-06 1.82E-06 2.52E-05 2.79E--06 1.35E-06 3.35E-04 5. 1OE-03 1.85E-05 1.14E-05 1.51E-06 4.10E-04 4.54E-03 3.48E-02 37 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-2A: Liquid Effluents
-Batch Mode Unit: 4 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released B. Tritium H-3 C. Dissolved and Entrained Gases Kr-85 Xe-133 Total For Period D. Gross Alpha Activity No Nudides Found Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Ci Ci 8.42E+01 4.66E-04 7.70E+01 O.OOE+OO 1.37E+01 O.OOE+00 3.50JE+01 O.OOE+OO Ci 1.50E-06 O.OOE+OO O.OOE+OO O.OOE+OD C7i 4.68E-04 O.OOE+00 O.OOE+OO 0.00E+00 4.66E-04 1-50E-06 4.69E-04 G O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+o0 38 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-2B: Liquid Effluents
-Continuous Mode Unit: 4 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Nuclides Released A. Fission and Activation Products No Nudides Found B. Tritium No Nudides Found C. Dissolved and Entrained Gases No Nudides Found D. Gross Alpha Activity No Nudides Found Continuous Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Ci Ci Ci o.oOE+ao O.OOE+00 O.OOE+OO O.OOE+00 O.OOE+00 O.0OE+00 O.OOE+OO O.OOE+OO O.OOE+00 o.OoE+0a O.OOE+OO O.OOE+OO O.OOE+0O O.00E+00 0.00E+00 39 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Dose to a member of the public due to Liquid Release Unit: 4 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Ogan Dose Bone Limit Percent of Limit Units 1ST Quarter mRem 2.16E-05 mRem 5.000% 0.000 2ND Quarter 5.30E-05 5.000 0.001 3RD Quarter 1.81E-05 5.000 0.000 4TH Quarter 6.56E-05 5.000 0.001 Annual 1.58E-04 10.000 0.002 Liver mRem 2.16E-05 5.30E-05 1.81E-05 6.56E-05 1.58E-04 Limit mRem 5.000 5.000 5.000 5,000 10.000 Percent of Limit % 0.000 0.001 0.000 0.001 0.002 Total Body mRem 2.16E-05 5.30E-05 1.81E-05 6.56E-05 1.58E-04 Limit mRem 1.500 1.500 1.500 1.500 3.000 Percent of Limit % 0.001 0.004 0.001 0.004 0.005 Thyroid mRem 2.16E-05 5.30E-05 1.81E-05 6.56E-05 1.58E-04 Limit mRern 5.000 5.000 5.000 5.000 10.000 Percent of Limit % 0.000 0.001 0.000 0.001 0.002 Kidney mRem 2.16E-05 5.30E-05 1.81E-05 6.56E-05 1,58E-04 Limit mRem 5.000 5.000 5,000 5.000 10.000 Percent of Limit % 0.000 0.001 0.000 0.001 0.002 Lung mRem 2.16E-05 5,30E-05 1.81E-05 6.56E-05 1.58E-04 Limit mRem 5.000 5.000 5.000 5.000 10.000 Percent of Limit % 0.000 0.001 0.000 0.001 0.002 GI-Lli mRem 2.16E-05 5.30E-05 1.81Eo05 6.56E-05 1.58E-04 Limit mRem 5.000 5.000 5.000 5.000 10.000 Percent of Umit % 0.000 0.001 0.000 0.001 0.002 40 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Dose to a member of the public due to Liquid Release Unit: 4 Starting:
1-Jan-2013 Ending: 31-Dec-2013 OWa Dose]SWd UL1mit Ptsrent df11n Units 1ST Quarter 2ND 'Quarter rnRern 2-7E-"05 6&ITt-05 mnpeva U03 5.0C-0 ofim0. Wt1 3RD Quartber 4TH Quarter 2-11E-65 7.66&-0 O-CO0 0.02 Annual t84E-C4 1C0.03~0.002 41 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Air Dose Due to Gaseous Releases Unit: 4 Starting:
1-Jan-2013 Ending: 31-Dec-2013 NG Dose Gamma Air Limit Percent of Limit Beta Air Limit Percent of Limit NG Total Body Limit Percent of Limit NG Skin Limit Percent of Limit Units mRad mRad mRad mRad mRem mRern 1ST Quarter 8.75E-07 5 1.75E-05 1.70E-06 10 1.70E-05 7.87E-07 N/A N/A 1.78E-06 N/A N/A 2ND Quarter 5.01E-09 5 1.OOE-07 1.48E-08 10 1.48E-07 4.18E-09 N/A N/A 9.90E-09 N/A N/A 3RD Quarter 6.39E-09 5 1.28E-07 1.94E-08 10 1.94E-07 5.30E-09 N/A N/A 1.28E-08 N/A N/A 4TH Quarter 4.25E-08 5 8.50E-07 9.91E-08 10 9.91 E-07 3.71E-08 N/A NIA 8.43E-08 NIA N/A Annual 9.29E-07 10 9.29E-06 1.83E-06 20 9.15E-06 8.33E-07 500 1.67E-07 1.89E-06 3000 6.30E-08 m Rein mRem%m Rem nRem 42 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Dose due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: 4 Starting:
1-Jan-2013 Ending: 31-Dec-2013 Organ Dose Uver Limit Percent of Umit Units mnRem mRem 1ST Quarter 1.82E-05 7.500 0.000 2ND Quarter 2.15E-05 7.500 0.000 3RD Quarter 8.31E-06 7.500 0.000 4TH Quarter 0.00E+00 7.500 0.000 Annual 4.80E-05 15.000 0.000 Total Body mRemn 1.82E-05 2.15E-05 8.31E-06 0.OOE+00 4.80E-05 Limit mRern N/A NIA N/A N/A NIA Percent of Limit % N/A N/A N/A N/A NIA Thyroid mRem 1.82E-05 2.15E-05 8.31E-06 0.OOE+00 4.80E-05 Limit mRem 7.500 7.500 7.500 7.500 15.000 Percent of Limit % 0.000 0.000 0.000 0.000 0.000 Kidney mRem 1.82E-05 2.15E-05 8.31E-06 O.OOE+00 4.80E-05 Limit mRem 7.500 7.500 7.500 7.500 15.000 Percent of Limit % 0.000 0.000 0.000 0.000 0.000 Lung mRem 1.82E-05 2.15E-05 8.31E-06 0.OOE+00 4.80E-05 Limit mRem 7.500 7.500 7.500 7.500 15.000 Percent of Limit % 0.000 0.000 0.000 0.000 0.000 GI-Li mRem 1.82E-05 2.15E-05 8.31E-06 0.OOE+00 4.80E-05 Umit mRern 7.500 7.500 7.500 7.500 15.000 Percent of Umit % 0.000 0.000 0.000 0.000 0.000 43 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Liquid and Gas Batch Release Summary Unit: 4 Starting:
1-Jan-2013 Ending: 31-Dec-2013 A. Liquid Batch Release Tot 1. Number of Batch Releases 2. Total duration of batch relez 3. Maximum batch release dur 4. Average batch release durat 5. Minimum batch release durc Units 1st Quarter 45 min 4.75E+03 min 1.34E+02 min 1.06E+02 min 9.00E+01 Units 1st Quarter 29 min 6.74E+04 min 2.74E+04 min 2.32E+03 min 3.OOE+01 2nd Quarter 34 3.37E+03 1.20E+02 9.92E+01 8.60E+01 2nd Quarter 4 1.62E+02 4.50E+01 4.05E+01 3.60E+01 3rd Quarter 17 1.67E+03 1.23E+02 9.85E+01 7.OOE+01 4th Quarter 12 1.16E+03 1.05E+02 9.65E+01 7.00E+01 Year Totals 108 1.10E+04 1.34E+02 1.01E+02 7.OOE+01 Year Totals 39 6.92E+04 2.74E+04 1.77E+03 3.OOE+01 B. Gas Batch Release Totals 1. Number of Batch Releases 2. Total duration of batch releases 3. Maximum batch release duration 4. Average batch release duration 5. Minimum batch release duration 3rd Quarter 4th Quarter 2 6.90E+01 3.50E+01 3.45E+01 3.40E+I01 4 1.57E+03 1.44E+i03 3.92E+02 3.10E+01 44 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table 6: Liquid and Gas Abnormal Release Summary Unit: 4 Starting:
1-Jan-2013 Ending: 31-Dec-2013 se Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th Ses0 0 0 releases Ci O.OOE+00 O.OOE+DO O.OOE+0 0.(Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th ases 0 0 0 releases Ci 0.OOE÷00 0.OOE+00 0.00E+00 3.A. Liquid Abnormal Relea 1. Number of Abnormal Rele 2. Total Activity of abnormal B. Gas Abnormal Release 1. Number of Abnornmal ReIe4 2. Total Actvity of abnormal Quarter 0 00E+00 Quarter 1 41E-03 Year Totals 0 0.00E+00 Year Totals 1 3.41E-03 45 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Site Dose Reg. Guide 1.21 Tables: 1. Table A-i: Gaseous Effluents
-Summation of all Releases 2. Table A-IA: Gaseous Effluents
-Ground Level Release -Batch Mode 3. Table A-1B: Gaseous Effluents
-Ground Level Release -Continuous Mode 4. Table A-IC: Gaseous Effluents
-Elevated Release -Batch Mode 5. Table A-1D: Gaseous Effluents
-Elevated Release -Continuous Mode 6. Table A-1E: Gaseous Effluents
-Mixed Mode Release -Batch Mode 7. Table A-1F: Gaseous Effluents
-Mixed Mode Release -Continuous Mode 8. Table A-2: Liquid Effluents
-Summation of all Releases 9. Table A-2A: Liquid Effluents
-Batch Mode 10. Table A-2B: Liquid Effluents
-Continuous Mode 11. Table A-4: Dose Assessments 10 CFR Part 50, Appendix 1: Dose to a member of the public due to Liquid Release 12. Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Air Dose Due to Gaseous Releases 13. Table A-4: Dose Assessments 10 CFR Part 50, Appendix 1: Dose due to Radioiodines, Tritium, and Particulates in Gaseous Releases 14. Liquid and Gas Batch Release Summary 15. Table 6: Liquid and Gas Abnormal Release Summary 46 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-i: Gaseous Effluents
-Summation of all Releases Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases 1. Total Release Ci 1.98E-01 1.41E-03 1.85E-03 8.49E-03 2.10E-01 2. Average Release Rate for Period uCi/s 2.55E-02 1.79E-04 2.32E-04 1.07E-03 6.65E-03 3. Percent of Limit % N/A N/A N/A N/A NIA B. Iodines and Halogens 1. Total Release Ci O.OOE+00 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 2. Average Release Rate for Period uCi/s O.OOE+00 O.OOE+00 O.O0E+00 O.OOE+00 O.OOE+O0 3. Percent of Limit % NIA N/A NIA N/A N/A C. Particulates
- 1. Total Release Ci 8.42E-05 O.OOE+00 O.OOE+00 2.58E-04 3.43E-04 2. Average Release Rate for Period uCi/s 1.08E-05 O.OOE+00 0.00E+00 3.25E-05 1.09E-05 3. Percent of Limit % N/A N/A N/A N/A N/A D. Tritium 1. Total Release Ci 5.07E+01 8.64E+01 2.55E+01 1.23E+01 1.75E+02 2. Average Release Rate for Period uCi/s 6.51E+00 1.10E+01 3.21E+00 1.55E+00 5.54E+00 3. Percent of Limit % N/A NIA N/A N/A N/A E. Gross Alpha 1. Total Release Ci 0.00E+00 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+O0 F. Carbon-14 1. Total Release Ci 3.38E+00 3.38E+00 3.38E+00 3.38E+00 1.35E+01 2. Average Release Rate for Period uCi/s 4.34E-01 4.30E-01 4.25E-01 4.25E-O1 4.28E-01 3. Percent of Limit %47 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-1A: Gaseous Effluents
-Ground Level Release -Batch Mode Unit: Site Starting:
I-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released A. Fission and Activation Gases Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual No Nuclides Found B. lodines and Halogens a a 0.OOE+00 O.OOE+O0 0.00E+00 0.OOE-+O0 O.OQE+OO 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 No Nuclides Found C. Particulates Mn-54 Co-58 Co-60 Zn-65 Sb-122 Sb-125 Cs-134 Cs-137 Total For Period D. Tritium H-3 Ci Ci Ci Ci a I ci Ci cl O.QOE+0O 3.37E-07 3.53E-07 8.36E-05 0.OOE+00O 0.00E4-00 O.OOE+00 O.OOE+0O 8.42E-05 O.OOE+OO O.OOE+0O O.OOE+0O 0.OOE+0O O.00E+00 0.00 E+i00 0.OOE+00 0.OOE+O0 O.OOE+00 0.00E+00 0.OOE+O0 0.OOE+00 O.OOE+00 0.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 O.OOE+OO 1.59E-06 1.06E-05 2.34E-05 O.OOE+00 5.51E-07 1.09E-05 5.82E-06 2.05E-04 2.58E-04 1 .59E-06 1.09E-05 2.38E-05 8436E-05 5.51E-07 1.09E-05 5.82E-06 2.05E-04 3-43E-04 E. Gross Alpha No Nudides Found F. Carbon-14 a 0 Ci a 2.87E-01 0.OOE+O0 O.OOE+00 0.COE+00 0.00E+00 0.00E+00 OXJOE+00 0.OOE+00 0.OOE+00 3.15E-03 O.OOE-e00 0.OOE-i00 2.91E-01 0.OOE+00 0.0()E+00 No Nuclides Found 48 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-1B: Gaseous Effluents
-Ground Level Release -Continuous Mode Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Continuous Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases No Nuclides Found a O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 B. Iodines and Halogens No Nuclides Found Ci O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 C. Particulates No Nuclides Found Ci O.OE+00 O.OOE+00 O.OOE+00 0.00r:+00 O.OOE+00 D. Tritium H-3 Ci 4.83E+01 8.38E+01 2.47E+01 1.22E+01 1.69E+02 E. Gross Alpha No Nudlides Found Ci 0.00E+00 O.OOE+0D .0O.E+00 0.00E+00 0.00E+00 F. Carbon-14 No Nuclides Found Ci O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 49 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-IC: Gaseous Effluents
-Elevated Release -Batch Mode Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases No Nudides Found Ci O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+00 B. Iodines and Halogens No Nudides Found Ci O.OOE+00 O.00E+00 O.OOE+00 0.00E+00 O.OOE+00 C. Particulates No Nuclides Found C0 O.OOE+00 0.OOE+0O 0.00E+00 O.OOE+O0 O.OOE+00 D. Tritium No Nudides Found Ci 0.00E+00 O.OOE+O0 0.00E+00 0.OOE+O0 O.OOE+00 E. Gross Alpha No Nudides Found Ci 0.O0E+00 0.OOE+00 O.OOE+OE O.OOE+OO O.OOE+0O F. Carbon-14 No Nuclides Found Ci O.OOE+O0 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 50 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-1D: Gaseous Effluents
-Elevated Release -Continuous Mode Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Continuous Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases No Nuclides Found Ci 0.00E+00 .OOE+00 O.OOE+OO O.OOE+O O.00E+O0 B. lodines and Halogens No Nuclides Found Ci O.00E+00 0.00E+00 O.OOE+00 O.OOE+00 O.OOE+00 C. Particulates No Nuclides Found Ci O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 0.00E+00 D. Tritum No Nuclides Found Ci O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 E. Gross Alpha No Nuclides Found Ci O.OOE+00 O.O0E+00 O.OOE+00 0.00E+00 O.OOE+00 F. Carbon-14 No Nuclides Found Ci O.OOE+00 O.OOE+00 O.OOE+00 000E+00 O.OOE+00 51 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-1E: Gaseous Effluents
-Mixed Mode Release -Batch Mode Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released A. Fission and Activation Gases Ar-41 Kr-85m Kr-87 Kr-88 Xe-131m Xe-133m Xe-133 Xe-135 Total For Period Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Ci Ci 0 a Ci Ci Ci 2.58E-04 2.23E-04 1.12E-06 5.90E-05 0.00 E+00 2.02E-03 1.69E-01 2.61E-02 1.98E-01 a.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 0.00 E+00 0.00E+00 1.40E-03 2.92E-06 1.41E-03 0.OOE+00 0.OOE+00 0.00E+00 C.OOE-.00 5.88E-05 0.OOE+00 1.79E-03 2.65 E-16 1.85E-03 2.67E-05 1 .46E-05 5.34E-07 1 .24E-05 0.OOE-I00 3.95E-05 7.76E-03 6.32E-04 8.49E-03 Annual 2.84E-04 2.38E-04 1 .65E-06 7.15E-05 5.88E-05 2.06E-03 1.80E-01 2.68E-02 2.10E-01 B. Iodines and Halogens No Nuclides Found C. Particulates No Nuclides Found D. Tritium H-3 a ci ci Ci Ci 0.OOE+400 a.00E+00 1.55E-03 0.OOE+00 0.00E+GO 0.OOE+00 0.IJOE+00 0.OOE+0O 0.OOE+00 0.OOE+00 0.00E+00 0.OOE400 0.OOE+00 0.00E+00 0.OOE-*00 0.00E+00 0.00E+00 0.OOE+00 0.00E4-00 0.00 E+00 0. 00E00 0.00E÷00 1.55E-03 0.OOE+00 0.00E+OO E. Gross Alpha No Nuclides Found F. Carbon-14 No Nuclides Found 52 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-IF: Gaseous Effluents
-Mixed Mode Release -Continuous Mode Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Continuous Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases No Nuclides Found Ci O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 B. lodines and Halogens No Nuclides Found Ci O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 C. Particulates No Nuclides Found Ci O.OOE+0 O.OOE+O0 O.OOE+OO 0.O0E+00 O.OOE+O0 D. Tritium H-3 Ci 2.04E+00 2.60E+00 8.43E-01 1.16E-01 5.60E+00 E. Gross Alpha No Nuclides Found Ci O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 F. Carbon-14 C-14 Ci 3.38E+00 3.38E+00 3.38E+00 3.38E+00 1.35E+01 53 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-2: Liquid Effluents
-Summation of all Releases Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Products 1. Total Release Ci 1.80E-02 2.20E-02 7.15E-03 2.24E-02 6.96E-02 2. Average Concentration uCi/mi 4.98E-11 3.31E-11 9.33E-12 3.81E-11 3.21E-11 3. Percent of Limit % 7.11E-07 4.73E-05 1.33E-05 5.44E-05 4.58E-05 B. Tritium 1. Total Release Ci 1.68E+02 1.54E+02 2.75E+01 6.99E+01 4.20E+02 2. Average Concentration uCi/mL 4.66E-07 2.31E-07 3.59E-08 1.19E-07 1.94E-07 3. Percent of Umit % 4.66E-03 2.31E-03 3.59E-04 1.19E-03 1.94E-03 C. Dissolved and Entrained Gases 1. Total Release Ci 9.36E-04 O.OOE+00 0.00E+00 0.00E+00 9.36E-04 2. Average Concentration uCi/mL 2.59E-12 O.OOE+00 O.OOE+00 O.OOE+00 4.31E-13 3. Percent of Limit % 1.30E-06 O.OOE+00 O.OOE+00 O.OOE+00 2.16E-07 D. Gross Alpha Activity 1. Total Release Ci O.OOE+00 O.OOE+00 O.OOE+00 0.00E+00 O.OOE+00 2. Average Concentration uCi/mL O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 E. Primary Liquid Release Volume 1. Total Release Liters 1.22E+06 8.90E+05 4.39E+05 3.19E+05 2.86E+06 F. Dilution Volume 1. Total Release Liters 3.61E+11 6.67E+11 7.66E+11 5.90E+11 2.17E+12 54 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-2A: Liquid Effluents
-Batch Mode Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode Nuclides Released A. Fission and Activation Products Units 1SI Quarter 2ND Quarter 3RD Quarter 4TH Quarter Na-24 Cr-51 Mn-54 Fe-5S Fe-59 Co-57 Co-58 Co-60 Ni-63 Zn-65 Br-82 Nb-95 Nb-97 Ag-1r0m Sn-117m Sb-122 Sb-124 Sb-125 1-131 1-133 1-134 Cs-134 Cs-137 Total For Period Q Ci Ci a Ci a 0 Ci Ci Q Q 0 ci Ci a Ci Ci Ci Ci Ci O.OOE+00 4.66E-04 O.OOE+OO 3.52E-03 1.25 E-05 O.OOE+OO 2.63E-03 1. 16E-04 3.91E-03 O.OOE+00 O.OOE+00 8. 12E-06 O.OOE+00 5.04E-05 4,57E-06 O.OOE÷OO 6.3ZE-04 6.24E-03 3.40E-06 7.73E-06 3.01E-06 8.78E-06 3.79E-04 1.80E-02 4.21E-05 O.OOE+0O 1.31E-04 1.59E-03 O.OOE+OO 4. 16E-06 1.03E-02 5.13E-04 3.52E-03 o.aOE+0O 3.23E-06 6. 15E-06 O.OOE+OO O-00E+00 1.01E-06 2.70E-06 3.72E-05 2.38E-03 2.25E-05 8.92E-06 O.OOE+0O 3.27E-04 3.09E-03 2.20E-02 O.OOE+OO O.OOE+00 1.59E-05 4.83E-04 O.OOE+OO 3.52E-06 1.45E-03 1.91E-04 2.92E-03 O.OOE+OO O.OOE+OO O.OOE+00 O.OOE+OO O.00E4-OO O.OOE+OO O.O0E+00 O.CCE+OO 9.OOE-04 O.OOE+0O a.OOE+oO C.OOE+0O 9.41E-05 1.09E-03 7-I5E-03 O.OOE+flO O.OOE+OO 3.16E-04 1. 10E-03 O.OOE+OO 3.69E-05 2.36E-03 7.06E-04 1.23E-02 8.23E-06 O.OOE+OO O.00E4-OO 3.64E-06 O.OOE+OO a.OoE+OO O.OOE+0O O.OOE+OO 6.85E-04 1.12E-05 6.07E-06 O.OOE+0O 3.89E-04 4.51E-03 2.24E-02 Annual 4.21E-05 4.66E-04 4.63E-04 6.70E-03 1.25E-05 4.46E-05 1.68E-02 1.53E-03 2.27E-02 8.23E-06 3.23E-06 1,43E-05 3.64E-06 5.04E-05 5.58E-06 2.70E-06 6.69E-04 1.02E-02 3.71E-05 2.27E-05 3.01E-06 8. 19E-04 9.07E-03 6.96E-02 55 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-2A: Liquid Effluents
-Batch Mode Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Batch Mode 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Nuclides Released B. Tritium H-3 Units G 1.68E+02 1.54E+02 2.75E+01 6.99E+01 4.20E+02 C. Dissolved and Entrained Gases Kr-85 Xe-133 Total For Period D. Gross Alpha Activity No Nudides Found Gi 9.33E-04 C, 2.99E-06 Ci 9.36E-04 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+O0 O.OOE+00 O.OOE+0O 9.33E-04 O.OOE+/-OO 2.99E-06 O.00EI-00 9.36E-04 Ci O.OOE+O0 O.O0E+00 O.OOE+O0 O.OOE+O0 O.OOE+00 56 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-2B: Liquid Effluents
-Continuous Mode Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Continuous Mode Nuclides Released A. Fission and Activation Products No Nudides Found B. Tritium No Nudides Found C. Dissolved and Entrained Gases No Nudides Found D. Gross Alpha Activity No Nudides Found Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual CI O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 Q O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 Ci O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 O.OOE+O0 G O.OOE+O0 O.OOE+O0 OOOE+O0 O.OOE+O0 O.OOE+O0 57 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Dose to a member of the public due to Liquid Release Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Ogan Dose Bone Limit Percent of Limit Units 1ST Quarter mRem 4.31E-05 2ND Quarter 1.06E-04 10.000 0.001 3RD Quarter 3.63E-05 10.000 0.000 4TH Quarter 1.31E-04 10.000 0.001 Annual 3.17E-04 20.000 0.002 mRem 10.000 0.000 Liver mRem 4.31E-05 1.06E-04 3.63E-05 1.31E-04 3.17E-04 Umit mRem 10.000 10.000 10.000 10.000 20.000 Percent of Limit % 0.000 0.001 0.000 0.001 0.002 Total Body mRem 4.31E-05 1.06E-04 3.63E-05 1.31E-04 3.17E-04 Limit mRem 3.000 3.000 3.000 3.000 6.000 Percent of Limit % 0.001 0.004 0.001 0.004 0.005 Thyroid mRem 4.31E-05 1.06E-04 3.63E-05 1.31E-04 3.17E-04 Limit mRem 10.000 10.000 10.000 10.000 20.000 Percent of Limit % 0.000 0.001 0.000 0.001 0.002 Kidney mRem 4.31 E-05 1.06E-04 3.63E-05 1.31E-04 3.17E-04 Limit mRem 10.000 10.000 10.000 10.000 20.000 Percent of Lmit % 0.000 0.001 0.000 0.001 0.002 Lung mRem 4.31E-05 1.06E-04 3.63E-05 1.31E-04 3.17E-04 Limit mRem 10.000 10.000 10.000 10.000 20.000 Percent of Limit % 0.000 0.001 0.000 0.001 0.002 GI-Lli mRem 4.31E-05 1.06E-04 3.63E-05 1.31E-04 3.17E-04 Limit mRem 10.000 10.000 10.000 10.000 20.000 Percent of Limit % 0.000 0.001 0.000 0.001 0.002 58 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Dose to a member of the public due to Liquid Release Unit Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Ogan Dose SUn Urcrit Perce fUi units 1ST Quarter 4.93E0 rMREM 10.0wE~v 0.03)2ND Quatrb~l.23-ZO0 10-0301 3RD Quafter-a.22E,05-0-90D OAX.0 4TH Quarter 1-53-=-04 I0.[40 O.C4O2 Annual 3.6KE-'J4 20. C40 0. C02 59 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Air Dose Due to Gaseous Releases Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 NG Dose Gamma Air Limit Percent of Limit Units mRad mRad 1ST Quarter 2.27E-06 10.000 2.27E-05 2ND Quarter 1.OOE-08 10.000 1.OOE-07 3RD Quarter 1.28E-08 10.000 1.28E-07 4TH Quarter 8.50E-08 10.000 8.50E-07 Annual 2.37E-06 2-0.000 1.19E-05 Beta Air mRad 4.93E-06 2.96E-08 3.88E-08 1.98E-07 5.19E-06 Limit mRad 20.000 20.000 20.000 20.000 40.000 Percent of Limit % 2.47E-05 1.48E-07 1.94E-07 9.91E-07 1.30E-05 NG Total Body mRem 2.00E-06 8.35E-09 1.06E-08 7.41E-08 2.1OE-06 Limit mRem N/A NIA NIA NIA 500 Percent of Limit % N/A NIA NIA NIA 4.20E-07 NG Skin mRem 4.59E-06 1.98E-08 2.57E-08 1.69E-07 4.80E-06 Limit mRem N/A NIA N/A N/A 3000 Percent of Limit % N/A N/A NIA N/A 1.60E-07 60 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Dose due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 Organ Dose Bone Limit Percent of Limit Units 1ST Quarter mRem 4.97E-03 mRem 15.000% 0.033 2ND Quarter 4.98E-03 15.000 0.033 3RD Quarter 4.98E-03 15.000 0.033 4TH Quarter 4.98E-03 15.000 0.033 Annual 1.99E-02 30.000 0.066 Liver mRem 4.99E-03 5.00E-03 4.98E-03 4.98E-03 2.OOE-02 Limit mRem 15.000 15.000 15.000 15.000 30.000 Percent of Limit 0 0.033 0.033 0.033 0.033 0.067 Total Body mRern 4.99E-03 5.OOE-03 4.98E-03 4.98E-03 2.00E-02 Limit mRem N/A NIA NIA NIA N/A Percent of Limit 0 N;A .... N!, NIA NIA Thyroid mRem 4.99E-03 5.OOE-03 4.98E-03 4.98E-03 2.00E-02 Limit mRem 15.000 15.000 15.000 15.000 30.000 Percent of Umit % 0.033 0.033 0.033 0.033 0.067 Kidney mRem 1.11E-03 1.82E-03 7.18E-04 7.14E-04 3.93E-03 Limit mRem 15.000 15.000 15.000 15.000 30.000 Percent of Limit 0 0.007 0.012 0.00S 0.005 0.013 Lung mRem 4.99E-03 5.00E-03 4.98E-03 4.98E-03 2.0(E-02 Limit mRem 15.000 15.000 15.000 15.000 30.000 Percent of Limit 0/0 0.033 0.033 0.033 0.033 0.067 GI-Lli mRern 4.99E-03 5.OOE-03 4.98E-03 4.98E-03 2.OOE-02 Limit mRem 15.000 15.000 15.000 15.000 30.000 Percent of Limit 0 0.033 0.033 0.033 0.033 0.067 61 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 The totals are not adding up. Liquid and Gas Batch Release Summary Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 A. Uquid Batch Release Totals 1. Number of Batch Releases 2. Total duration of batch releases 3. Maximum batch release duration 4. Average batch release duration 5. Minimum batch release duration B. Gas Batch Release Totals 1. Number of Batch Releases 2. Total duration of batch releases 3. Maximum batch release duration 4. Average batch release duration 5. Minimum batch release duration Units 1st Quarter 45 mrin 4.75E+03 min 1.34E+02 mrin 1.06E+02 min 9.OOE+01 Units 1st Quarter 30 min 8.03E+04 min 2.74E+04 min 2.68E+03 min 3.OOE+01 2nd Quarter 34 3.37E+03 1.20E+02 9.92E+01 8.60E+01 2nd Quarter 4 1.62E+02 4.50E+01 4.05E+01 3.80E+01 3rd Quarter 17 1.67E+03 1.23E+02 9.85E+01 7.00E+01 4th Quarter 12 1.16E+03 1.05E+02 9.65E+01 7.00E+01 Year Totals 108 1.10E+04 1.34E+02 1.01E+02 7.O0E+01 Year Totals 40 8.21E+04 2.74E-+04 2.05E+03 3.OOE+01 3rd Quarter 4th Quarter 2 6.90E+01 3.50E4-01 3.45E+i01 3.40E+01 4 1.57E+03 1.44E+03 3.92E+02 3.10E+01 62 A. Liquid Abnormal Releas 1. Number of Abnormal Rele]2. Total Activity of abnormal B. Gas Abnormal Release 1. Number of Abnormal Relel 2. Total Activy of abnormal TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 Table 6: Liquid and Gas Abnormal Release Summary Unit: Site Starting:
1-Jan-2013 Ending: 31-Dec-2013 se Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th ases 0 0 0 releases O.OOE+O0 0.00E+00 O.OOE+O0 0.Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th 3ses 0 0 0 releases 0 0.OOE+O0 0.OOF+00 0.OOE+0O 3.Quarter 0 OOE+O0 Quarter I.41E-03 Year Totals 0 O.OOE+00 Year Totals 1 3.41E-03 63 ATTACHMENT A REG. GUIDE 1.21 Table A-3 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL 1. TYPE OF WASTE a. Spent resin, filters, sludge, evaporator bottoms, etc.b. Dry compressible waste (Note 1)c. Irradiated components, control rods, etc.UNITS 12 MONTH PERIOD m 3 Ci m3 Ci m3 Ci 3.00 E +00 5.05 E +01 1.55 E+03 1.72 E+00 0.00 E+00 0.00 E+00% ERROR 2.00 E+00 2.00 E+00 2.00 E+00 2.00 E+00 d. Other: m 3 1.08 E+02 non-compressed Ci 4.37 E-02 2. ESTIMATE OF MAJOR NUCLIDE COMPOSITION (by type of waste)a. NUCLIDE UNITS VALUE Fe-55 % 5.01 Co-58 % 3.45 Co-60 % 11.03 Ni-63 % 59.82 Cs-134 % 8.38 Cs-137 % 9.91 b. NUCLIDE UNITS VALUE Fe-55 % 30.44 Co-58 Co-60 Ni-63 Zr-95 Zn-65 Nb-95 6.36 5.49 12.35 3.25 31.88 6.24 65 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 ATTACHMENT A REG. GUIDE 1.21 Table A-3 c. NUCLIDE d. NUCLIDE Fe-55 Co-58 Co-60 Ni-63 Zn-65 Nb-95 UNITS None shipped UNITS VALUE VALUE 44.97 9.81 8.01 16.78 5.01 9.63 3. SOLID WASTE DISPOSITION (Note 2)Number of Shipments 40 6 1 I Mode of Transportation Sole use truck Sole use truck Sole use truck Sole use truck Destination Energy Solutions Bear Creek Road Facility (Oak Ridge, TN)Energy Solutions Clive Facility (Clive, UT)Energy Solutions Gallaher Road Facility (Kingston, TN)Studsvik Processing Facility (Erwin, TN)B. IRRADIATED FUEL SHIPMENTS (Disposition)
None 65 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2013 THROUGH DECEMBER 2013 ATTACHMENT A REG. GUIDE 1.21 Table A-3 SOLID WASTE SHIPMENTS Waste Classification Total Volume Cubic Feet Total Curies (Note 3)Principal Radionuclides (Note 4)Type of Waste (Note 5)R.G. 1.21 Category Type of Container (Note 6)Class A Class B/C 5.84 E+04 1.06 E+02 1.77 E+00 5.05 E+01 None None Compressible Waste Primary Resin/Filters l.b, l.d General Design l.a. General Design/Type B/ Type A No solidification or absorbing agents were used or needed in the shipment of these waste types 66 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2012 THROUGH DECEMBER 2012 ATTACHMENT A REG. GUIDE 1.21 Table A-3 NOTE 1: Dry compressible waste volume indicates volume shipped to a burial site following reduction by a waste processing facility.NOTE 2: Material transported to Tennessee was consigned to licensed processing facilities for volume reduction and decontamination activities.
The material remaining after processing was transported by the processor to Clive, Utah in accordance with the appropriate burial license activity limits.NOTE 3: The total curie quantity and radionuclide composition of solid waste shipped from the Turkey Point Plant Units 3 and 4 are determined using a combination of qualitative and quantitative techniques.
The Turkey Point Plant follows the guidelines in the Low Level Waste Licensing Branch Technical Position on Radioactive Waste Classification (5/11/83) for these determinations.
The most frequently used techniques for determining the total activity in a package are the dose to curie method and inference from specific activity and mass or activity concentration and volume. Activation analysis may be applied when it is appropriate.
The total activity determination by any of these methods is considered to be an estimate.The composition of radionuclides in the waste is determined by periodic off-site analysis for difficult to measure isotopes.
Off-site analyses are used to establish scaling factors or other estimates for difficult to measure isotopes and principle Gamma emitters.NOTE 4: Principle radionuclide refers to those radionuclides contained in the waste in concentrations greater than 0.01 times the concentration of the nuclide listed in Table 1 or 0.01 times the smallest concentration of the nuclide listed in Table 2 of 10 CFR 61.55.NOTE 5: Type of waste is specified as described in NUREG 0782, Draft Environment Impact Statement on 10 CFR 61 "Licensing Requirements for Land Disposal of Radioactive Waste".NOTE 6: Type of container refers to the transport package.67 TURKEY POINT UNITS 3 AND 4 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 2012 THROUGH DECEMBER 2012 Attachment B ODCM Rev. 20 Issued 12/19/13 68